Dai J, Luo K, Liu Q, Unkovskiy A, Spintzyk S, Xu S, Li P. Post-processing of a 3D-printed denture base polymer: Impact of a centrifugation method on the surface characteristics, flexural properties, and cytotoxicity. J Dent 2024; 147:105102. [PMID: 38852693 DOI: 10.1016/j.jdent.2024.105102] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2023] [Revised: 05/22/2024] [Accepted: 05/24/2024] [Indexed: 06/11/2024] Open
Abstract
OBJECTIVES To investigate the impact of a centrifugation method on the surface characteristics, flexural properties, and cytotoxicity of an additively manufactured denture base polymer. METHODS The tested specimens were prepared by digital light processing (DLP). A centrifugation method (CENT) was used to remove the residual uncured resin. In addition, the specimens were post-processed with different post-rinsing solutions: isopropanol (IPA), ethanol (EtOH), and tripropylene glycol monomethyl ether (TPM), respectively. A commercial heat-polymerized polymethyl methacrylate was used as a reference (REF). First, the values of surface topography, arithmetical mean height (Sa), and root mean square height (Sq) were measured. Next, flexural strength (FS) and modulus were evaluated. Finally, cytotoxicity was assessed using an extract test. The data were statistically analyzed using a one-way analysis of variance, followed by Tukey's multiple comparison test for post-hoc analysis. RESULTS The Sa value in the CENT group was lower than in the IPA, EtOH, TPM, and REF groups (p < 0.001). Moreover, the CENT group had lower Sq values than other groups (p < 0.001). The centrifugation method showed a higher FS value (80.92 ± 8.65 MPa) than the EtOH (61.71 ± 12.25 MPa, p < 0.001) and TPM (67.01 ± 9.751 MPa, p = 0.027), while affecting IPA (72.26 ± 8.80 MPa, p = 0.268) and REF (71.39 ± 10.44 MPa, p = 0.231). Also, the centrifugation method showed no evident cytotoxic effects. CONCLUSIONS The surfaces treated with a centrifugation method were relatively smooth. Simultaneously, the flexural strength of denture base polymers was enhanced through centrifugation. Finally, no evident cytotoxic effects could be observed from different post-processing procedures. CLINICAL SIGNIFICANCE The centrifugation method could optimize surface quality and flexural strength of DLP-printed denture base polymers without compromising cytocompatibility, offering an alternative to conventional rinsing post-processing.
Collapse
Affiliation(s)
- Jingtao Dai
- Department of Orthodontics, Stomatological Hospital, School of Stomatology, Southern Medical University, South Jiangnan Road No. 366, Guangzhou 510280, China
| | - Ke Luo
- Center of Oral Implantology, Stomatological Hospital, Southern Medical University, South Jiangnan Road No. 366, Guangzhou 510280, China
| | - Qian Liu
- Center of Oral Implantology, Stomatological Hospital, Southern Medical University, South Jiangnan Road No. 366, Guangzhou 510280, China
| | - Alexey Unkovskiy
- Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité - University Hospital, Aßmannshauser Str. 4-6, Berlin 14197, Germany; Department of Dental Surgery, Sechenov First Moscow State Medical University, Bolshaya Pirogovskaya Street, 19с1, Moscow 119146, Russia
| | - Sebastian Spintzyk
- ADMiRE Lab - Additive Manufacturing, intelligent Robotics, Sensors and Engineering, School of Engineering and IT, Carinthia University of Applied Sciences, Europastraße 4, 9524 Villach, Austria
| | - Shulan Xu
- Center of Oral Implantology, Stomatological Hospital, Southern Medical University, South Jiangnan Road No. 366, Guangzhou 510280, China.
| | - Ping Li
- Department of Prosthodontics, School and Hospital of Stomatology, Guangdong Engineering Research Center of Oral Restoration and Reconstruction, Guangzhou Medical University, Guangzhou, China; Guangzhou Key Laboratory of Basic and Applied Research of Oral Regenerative Medicine, Guangzhou Medical University, Guangzhou, China.
| |
Collapse
|
2
|
Saramet V, Stan MS, Ripszky Totan A, Țâncu AMC, Voicu-Balasea B, Enasescu DS, Rus-Hrincu F, Imre M. Analysis of Gingival Fibroblasts Behaviour in the Presence of 3D-Printed versus Milled Methacrylate-Based Dental Resins-Do We Have a Winner? J Funct Biomater 2024; 15:147. [PMID: 38921521 PMCID: PMC11204847 DOI: 10.3390/jfb15060147] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2024] [Revised: 05/23/2024] [Accepted: 05/24/2024] [Indexed: 06/27/2024] Open
Abstract
Computer-aided design and computer-aided manufacturing (CAD/CAM) techniques are based on either subtractive (milling prefabricated blocks) or additive (3D printing) methods, and both are used for obtaining dentistry materials. Our in vitro study aimed to investigate the behavior of human gingival fibroblasts exposed to methacrylate (MA)-based CAD/CAM milled samples in comparison with that of MA-based 3D-printed samples to better elucidate the mechanisms of cell adaptability and survival. The proliferation of human gingival fibroblasts was measured after 2 and 24 h of incubation in the presence of these samples using a 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide assay, and the membrane integrity was assessed through the lactate dehydrogenase release. The level of reactive oxygen species, expression of autophagy-related protein LC3B-I, and detection of GSH and caspase 3/7 were evaluated by fluorescence staining. The MMP-2 levels were measured using a Milliplex MAP kit. The incubation with MA-based 3D-printed samples significantly reduced the viability, by 16% and 28% from control after 2 and 24 h, respectively. There was a 25% and 55% decrease in the GSH level from control after 24 h of incubation with the CAD/CAM milled and 3D-printed samples, respectively. In addition, higher levels of LC3B-I and MMP-2 were obtained after 24 h of incubation with the MA-based 3D samples compared to the CAD/CAM milled ones. Therefore, our results outline that the MA-CAD/CAM milled samples displayed good biocompatibility during 24-h exposure, while MA-3D resins are proper for short-term utilization (less than 24 h).
Collapse
Affiliation(s)
- Veaceslav Saramet
- Department of Complete Denture, Faculty of Dental Medicine, “Carol Davila” University of Medicine and Pharmacy, 020021 Bucharest, Romania; (V.S.); (M.I.)
| | - Miruna S. Stan
- Department of Biochemistry and Molecular Biology, Faculty of Biology, University of Bucharest, 91–95 Splaiul Independentei, 050095 Bucharest, Romania
| | - Alexandra Ripszky Totan
- Department of Biochemistry, Faculty of Dental Medicine, “Carol Davila” University of Medicine and Pharmacy, 020021 Bucharest, Romania; (A.R.T.); (D.S.E.); (F.R.-H.)
- The Interdisciplinary Center for Dental Research and Development, Faculty of Dental Medicine, “Carol Davila” University of Medicine and Pharmacy, 17–23 Plevnei Street, 020021 Bucharest, Romania;
| | - Ana Maria Cristina Țâncu
- Department of Complete Denture, Faculty of Dental Medicine, “Carol Davila” University of Medicine and Pharmacy, 020021 Bucharest, Romania; (V.S.); (M.I.)
| | - Bianca Voicu-Balasea
- The Interdisciplinary Center for Dental Research and Development, Faculty of Dental Medicine, “Carol Davila” University of Medicine and Pharmacy, 17–23 Plevnei Street, 020021 Bucharest, Romania;
| | - Dan Sebastian Enasescu
- Department of Biochemistry, Faculty of Dental Medicine, “Carol Davila” University of Medicine and Pharmacy, 020021 Bucharest, Romania; (A.R.T.); (D.S.E.); (F.R.-H.)
| | - Florentina Rus-Hrincu
- Department of Biochemistry, Faculty of Dental Medicine, “Carol Davila” University of Medicine and Pharmacy, 020021 Bucharest, Romania; (A.R.T.); (D.S.E.); (F.R.-H.)
| | - Marina Imre
- Department of Complete Denture, Faculty of Dental Medicine, “Carol Davila” University of Medicine and Pharmacy, 020021 Bucharest, Romania; (V.S.); (M.I.)
| |
Collapse
|
3
|
Haugli KH, Alkarra D, Samuelsen JT. Digital manufacturing techniques and the in vitro biocompatibility of acrylic-based occlusal device materials. Clin Oral Investig 2024; 28:312. [PMID: 38748326 PMCID: PMC11096251 DOI: 10.1007/s00784-024-05707-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2023] [Accepted: 05/06/2024] [Indexed: 05/18/2024]
Abstract
OBJECTIVES Material chemistry and workflow variables associated with the fabrication of dental devices may affect the biocompatibility of the dental devices. The purpose of this study was to compare digital and conventional workflow procedures in the manufacturing of acrylic-based occlusal devices by assessing the cytotoxic potential of leakage products. METHODS Specimens were manufactured by 3D printing (stereolithography and digital light processing), milling, and autopolymerization. Print specimens were also subjected to different post-curing methods. To assess biocompatibility, a human tongue epithelial cell line was exposed to material-based extracts. Cell viability was measured by MTT assay while Western blot assessed the expression level of selected cytoprotective proteins. RESULTS Extracts from the Splint 2.0 material printed with DLP technology and post-cured with the Asiga Flash showed the clearest loss of cell viability. The milled and autopolymerized materials also showed a significant reduction in cell viability. However, by storing the autopolymerized material in dH2O for 12 h, no significant viability loss was observed. Increased levels of cytoprotective proteins were seen in cells exposed to extracts from the print materials and the autopolymerized material. Similarly to the effect on viability loss, storing the autopolymerized material in dH2O for 12 h reduced this effect. CONCLUSIONS/CLINICAL RELEVANCE Based on the biocompatibility assessments, clinical outcomes of acrylic-based occlusal device materials may be affected by the choice of manufacturing technique and workflow procedures.
Collapse
Affiliation(s)
- Ketil Hegerstrøm Haugli
- NIOM, Nordic Institute of Dental Materials, Oslo, Norway.
- Dental Technology Program, Faculty of Health Sciences, Oslo Metropolitan University (OsloMet), OsloMet Box 4, St. Olavs plass, Oslo, 0130, Norway.
| | | | | |
Collapse
|
4
|
Cardoso BS, da Cruz MB, Marques JF, Roque JC, Martins JP, Malheiro RC, da Mata AD. Cellular responses to 3D printed dental resins produced using a manufacturer recommended printer versus a third party printer. J Adv Prosthodont 2024; 16:126-138. [PMID: 38694195 PMCID: PMC11058352 DOI: 10.4047/jap.2024.16.2.126] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2023] [Revised: 03/28/2024] [Accepted: 04/16/2024] [Indexed: 05/04/2024] Open
Abstract
PURPOSE The aim of this study was to evaluate the influence of different 3D dental resins, using a manufacturer recommended printer and a third-party printer, on cellular responses of human gingival cells. MATERIALS AND METHODS Three NextDent resins (Denture 3D+, C&B MFH and Crowntec) were used to produce specimens on printers NextDent 5100 (groups ND, NC and NT, respectively) and Phrozen Sonic Mini 4K (groups PD, PC and PT, respectively). Human gingival fibroblasts were cultured and biocompatibility was evaluated on days 1, 3 and 7. IL-6 and IL-8 concentrations were evaluated at 3 days using ELISA. Surface roughness was evaluated by a contact profilometer. SEM and fluorescence micrographs were analyzed at days 1 and 7. Statistical analyses were performed using SPSS and mean differences were tested using ANOVA and post-hoc Tukey tests (P < .05). RESULTS There was an increase in cellular viability after 7 days in groups PC and PT, when compared to group PD. ND group resulted in higher concentration of IL-6 when compared to PT group. SEM and fluorescence micrographs showed less adhesion and thinner morphology of fibroblasts from group PD. No significant differences were found regarding surface roughness. CONCLUSION The use of different printers or resins did not seem to influence surface roughness. NextDent 5100 and Phrozen Sonic Mini 4K produced resins with similar cellular responses in human gingival fibroblasts. However, Denture 3D+ resin resulted in significantly lower biocompatibility, when compared to C&B MFH and Crowntec resins. Further testing is required to support its long-term use, required for complete dentures.
Collapse
Affiliation(s)
- Beatriz Sona Cardoso
- Universidade de Lisboa, Faculdade de Medicina Dentária, Unidade de Investigação em Ciências Orais e Biomédicas (UICOB), Rua Professora Teresa Ambrósio, Portugal
| | - Mariana Brito da Cruz
- Universidade de Lisboa, Faculdade de Medicina Dentária, Unidade de Investigação em Ciências Orais e Biomédicas (UICOB), Rua Professora Teresa Ambrósio, Portugal
| | - Joana Faria Marques
- Universidade de Lisboa, Faculdade de Medicina Dentária, Unidade de Investigação em Ciências Orais e Biomédicas (UICOB), Rua Professora Teresa Ambrósio, Portugal
| | - João Carlos Roque
- Universidade de Lisboa, Faculdade de Medicina Dentária, Unidade de Investigação em Ciências Orais e Biomédicas (UICOB), Rua Professora Teresa Ambrósio, Portugal
- Universidade de Lisboa, Faculdade de Medicina Dentária, Departamento de Prótese Dentária - Laboratório de Tecnologias Digitais - DIGITECH, Rua Professora Teresa Ambrósio, Portugal
| | - João Paulo Martins
- Universidade de Lisboa, Faculdade de Medicina Dentária, Unidade de Investigação em Ciências Orais e Biomédicas (UICOB), Rua Professora Teresa Ambrósio, Portugal
- Universidade de Lisboa, Faculdade de Medicina Dentária, Departamento de Prótese Dentária - Laboratório de Tecnologias Digitais - DIGITECH, Rua Professora Teresa Ambrósio, Portugal
| | - Rodrigo Cordeiro Malheiro
- Universidade de Lisboa, Faculdade de Medicina Dentária, Departamento de Prótese Dentária - Laboratório de Tecnologias Digitais - DIGITECH, Rua Professora Teresa Ambrósio, Portugal
| | - António Duarte da Mata
- Centro de Estudos de Medicina Dentária Baseada na Evidência (CEMDBE) Cochrane Portugal, Faculdade de Medicina Dentária, Universidade de Lisboa, Rua Professora Teresa Ambrósio, Portugal
- Universidade de Lisboa, Faculdade de Medicina Dentária, Unidade de Investigação em Ciências Orais e Biomédicas (UICOB), LIBPhys-FTC UID/FIS/04559/2013, Rua Professora Teresa Ambrósio, Portugal
| |
Collapse
|
5
|
Matsuura T, Stavrou S, Komatsu K, Cheng J, Pham A, Ferreira S, Baba T, Chang TL, Chao D, Ogawa T. Disparity in the Influence of Implant Provisional Materials on Human Gingival Fibroblasts with Different Phases of Cell Settlement: An In Vitro Study. Int J Mol Sci 2023; 25:123. [PMID: 38203293 PMCID: PMC10779283 DOI: 10.3390/ijms25010123] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2023] [Revised: 12/13/2023] [Accepted: 12/19/2023] [Indexed: 01/12/2024] Open
Abstract
The development of healthy peri-implant soft tissues is critical to achieving the esthetic and biological success of implant restorations throughout all stages of healing and tissue maturation, starting with provisionalization. The purpose of this study was to investigate the effects of eight different implant provisional materials on human gingival fibroblasts at various stages of cell settlement by examining initial cell attachment, growth, and function. Eight different specimens-bis-acrylic 1 and 2, flowable and bulk-fill composites, self-curing acrylic 1 and 2, milled acrylic, and titanium (Ti) alloy as a control-were fabricated in rectangular plates (n = 3). The condition of human gingival fibroblasts was divided into two groups: those in direct contact with test materials (contact experiment) and those in close proximity to test materials (proximity experiment). The proximity experiment was further divided into three phases: pre-settlement, early settlement, and late settlement. A cell culture insert containing each test plate was placed into a well where the cells were pre-cultured. The number of attached cells, cell proliferation, resistance to detachment, and collagen production were evaluated. In the contact experiment, bis-acrylics and composites showed detrimental effects on cells. The number of cells attached to milled acrylic and self-curing acrylic was relatively high, being approximately 70% and 20-30%, respectively, of that on Ti alloy. There was a significant difference between self-curing acrylic 1 and 2, even with the same curing modality. The cell retention ability also varied considerably among the materials. Although the detrimental effects were mitigated in the proximity experiment compared to the contact experiment, adverse effects on cell growth and collagen production remained significant during all phases of cell settlement for bis-acrylics and flowable composite. Specifically, the early settlement phase was not sufficient to significantly mitigate the material cytotoxicity. The flowable composite was consistently more cytotoxic than the bulk-fill composite. The harmful effects of the provisional materials on gingival fibroblasts vary considerably depending on the curing modality and compositions. Pre-settlement of cells mitigated the harmful effects, implying the susceptibility to material toxicity varies depending on the progress of wound healing and tissue condition. However, cell pre-settlement was not sufficient to fully restore the fibroblastic function to the normal level. Particularly, the adverse effects of bis-acrylics and flowable composite remained significant. Milled and self-curing acrylic exhibited excellent and acceptable biocompatibility, respectively, compared to other materials.
Collapse
Affiliation(s)
- Takanori Matsuura
- Weintraub Center for Reconstructive Biotechnology, Division of Regenerative and Reconstructive Sciences, UCLA School of Dentistry, Los Angeles, CA 90095, USA; (S.S.); (J.C.); (A.P.); (T.B.); (T.-L.C.); (D.C.); (T.O.)
| | - Stella Stavrou
- Weintraub Center for Reconstructive Biotechnology, Division of Regenerative and Reconstructive Sciences, UCLA School of Dentistry, Los Angeles, CA 90095, USA; (S.S.); (J.C.); (A.P.); (T.B.); (T.-L.C.); (D.C.); (T.O.)
| | - Keiji Komatsu
- Weintraub Center for Reconstructive Biotechnology, Division of Regenerative and Reconstructive Sciences, UCLA School of Dentistry, Los Angeles, CA 90095, USA; (S.S.); (J.C.); (A.P.); (T.B.); (T.-L.C.); (D.C.); (T.O.)
| | - James Cheng
- Weintraub Center for Reconstructive Biotechnology, Division of Regenerative and Reconstructive Sciences, UCLA School of Dentistry, Los Angeles, CA 90095, USA; (S.S.); (J.C.); (A.P.); (T.B.); (T.-L.C.); (D.C.); (T.O.)
| | - Alisa Pham
- Weintraub Center for Reconstructive Biotechnology, Division of Regenerative and Reconstructive Sciences, UCLA School of Dentistry, Los Angeles, CA 90095, USA; (S.S.); (J.C.); (A.P.); (T.B.); (T.-L.C.); (D.C.); (T.O.)
| | | | - Tomomi Baba
- Weintraub Center for Reconstructive Biotechnology, Division of Regenerative and Reconstructive Sciences, UCLA School of Dentistry, Los Angeles, CA 90095, USA; (S.S.); (J.C.); (A.P.); (T.B.); (T.-L.C.); (D.C.); (T.O.)
| | - Ting-Ling Chang
- Weintraub Center for Reconstructive Biotechnology, Division of Regenerative and Reconstructive Sciences, UCLA School of Dentistry, Los Angeles, CA 90095, USA; (S.S.); (J.C.); (A.P.); (T.B.); (T.-L.C.); (D.C.); (T.O.)
| | - Denny Chao
- Weintraub Center for Reconstructive Biotechnology, Division of Regenerative and Reconstructive Sciences, UCLA School of Dentistry, Los Angeles, CA 90095, USA; (S.S.); (J.C.); (A.P.); (T.B.); (T.-L.C.); (D.C.); (T.O.)
| | - Takahiro Ogawa
- Weintraub Center for Reconstructive Biotechnology, Division of Regenerative and Reconstructive Sciences, UCLA School of Dentistry, Los Angeles, CA 90095, USA; (S.S.); (J.C.); (A.P.); (T.B.); (T.-L.C.); (D.C.); (T.O.)
| |
Collapse
|
6
|
Somogyi A, Végh D, Róth I, Hegedüs T, Schmidt P, Hermann P, Géczi Z. Therapy for Temporomandibular Disorders: 3D-Printed Splints from Planning to Evaluation. Dent J (Basel) 2023; 11:dj11050126. [PMID: 37232777 DOI: 10.3390/dj11050126] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2023] [Revised: 03/29/2023] [Accepted: 04/28/2023] [Indexed: 05/27/2023] Open
Abstract
INTRODUCTION This article describes the authors' digital workflow-based method for fabricating intraoral occlusal splints, from planning to the evaluation phase. MATERIALS AND METHODS In our protocol, first, we had a registration phase. This included taking digital impressions, determining the centric relation (CR) position with the deprogrammer Luci Jig, and using the digital facebow for measuring the individual values. The laboratory phase was next, which included planning and manufacturing with a 3D printer. The last phase was delivery, when we checked the stability of the splint and adjusted the occlusal part. RESULT The average cost is lower for a fully digital splint than for conventional methods. In terms of time, there was also a significant difference between the classic and digital routes. From a dental technical point of view, the execution was much more predictable. The printed material was very rigid and, therefore, fragile. Compared to the analog method, the retention was much weaker. CONCLUSION The presented method permits time-efficient laboratory production, and may also be performed chairside in a dental office. The technology is perfectly applicable to everyday life. In addition to its many beneficial properties, its negative properties must also be highlighted.
Collapse
Affiliation(s)
- Andrea Somogyi
- Department of Prosthodontics, Faculty of Dentistry, Semmelweis University, 1085 Budapest, Hungary
| | - Dániel Végh
- Department of Prosthodontics, Faculty of Dentistry, Semmelweis University, 1085 Budapest, Hungary
| | - Ivett Róth
- Department of Prosthodontics, Faculty of Dentistry, Semmelweis University, 1085 Budapest, Hungary
| | - Tamás Hegedüs
- Department of Prosthodontics, Faculty of Dentistry, Semmelweis University, 1085 Budapest, Hungary
| | - Péter Schmidt
- Department of Prosthodontics, Faculty of Dentistry, Semmelweis University, 1085 Budapest, Hungary
| | - Péter Hermann
- Department of Prosthodontics, Faculty of Dentistry, Semmelweis University, 1085 Budapest, Hungary
| | - Zoltán Géczi
- Department of Prosthodontics, Faculty of Dentistry, Semmelweis University, 1085 Budapest, Hungary
| |
Collapse
|