1
|
Gilbert DF, Friedrich O, Wiest J. Assaying Proliferation Characteristics of Cells Cultured Under Static Versus Periodic Conditions. Methods Mol Biol 2023; 2644:35-45. [PMID: 37142914 DOI: 10.1007/978-1-0716-3052-5_3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
Two-dimensional in vitro culture models are widely being employed for assessing a vast variety of biological questions in different scientific fields. Common in vitro culture models are typically maintained under static conditions, where the surrounding culture medium is replaced every few days-typically every 48 to 72 h-with the aim to remove metabolites and to replenish nutrients. Although this approach is sufficient for supporting cellular survival and proliferation, static culture conditions do mostly not reflect the in vivo situation where cells are continuously being perfused by extracellular fluid, and thus, create a less-physiological environment. In order to evaluate whether the proliferation characteristics of cells in 2D culture maintained under static conditions differ from cells kept in a dynamic environment, in this chapter, we provide a protocol for differential analysis of cellular growth under static versus pulsed-perfused conditions, mimicking continuous replacement of extracellular fluid in the physiological environment. The protocol involves long-term life-cell high-content time-lapse imaging of fluorescent cells at 37 °C and ambient CO2 concentration using multi-parametric biochips applicable for microphysiological analysis of cellular vitality. We provide instructions and useful information for (i) the culturing of cells in biochips, (ii) setup of cell-laden biochips for culturing cells under static and pulsed-perfused conditions, (iii) long-term life-cell high-content time-lapse imaging of fluorescent cells in biochips, and (iv) quantification of cellular proliferation from image series generated from imaging of differentially cultured cells.
Collapse
Affiliation(s)
- Daniel F Gilbert
- Institute of Medical Biotechnology, Department of Chemical and Biological Engineering (CBI), Friedrich-Alexander-University Erlangen-Nürnberg, Erlangen, Germany.
| | - Oliver Friedrich
- Institute of Medical Biotechnology, Department of Chemical and Biological Engineering (CBI), Friedrich-Alexander-University Erlangen-Nürnberg, Erlangen, Germany
| | | |
Collapse
|
2
|
Ritter P, Bye LJ, Finol-Urdaneta RK, Lesko C, Adams DJ, Friedrich O, Gilbert DF. A method for high-content functional imaging of intracellular calcium responses in gelatin-immobilized non-adherent cells. Exp Cell Res 2020; 395:112210. [PMID: 32750330 DOI: 10.1016/j.yexcr.2020.112210] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2020] [Revised: 07/15/2020] [Accepted: 07/28/2020] [Indexed: 11/28/2022]
Abstract
Functional imaging of the intracellular calcium concentration [Ca2+]i using fluorescent indicators is a powerful and frequently applied method for assessing various biological questions in vitro, including ion channel function and intracellular signaling in homeostasis and disease. In functional [Ca2+]i imaging experiments, the fluorescence intensity of single cells is typically recorded during application of a chemical stimulus, i.e. by exchange of modified extracellular media, exposure to drugs and/or ligands. The concomitant mechanical perturbation caused by the perfusion of different solution during experimentation severely hinders calcium imaging in non-adherent cells, including peripheral immune cells, as cells in suspension are dislocated by turbulent flow during chemical stimulation. The quantitative analysis, involving time-courses of intracellular fluorescence signal changes, necessitates cells to remain at the same position throughout the experiment. To prevent dislocation of cells during solution exchange, and to enable imaging as well as analysis of Ca2+ responses in immune cells, a gelatin-based method for immobilization of non-adherent cells was developed. Gelatin has been a long-serving material for cell immobilization, e.g. in 3D bio-printing of cells and has thus, also been employed in the context of this study. To demonstrate the applicability of the established method for functional Ca2+ imaging in gelatin-immobilized suspension cells, a proof-of-concept study was conducted using human peripheral blood model cell lines (Jurkat/T-lymphocytes and THP-1/monocytes), Ca2+ indicators (Fluo-4 and Fura-2) and two different fluorescence microscopy rigs. The data presented that the established methodology is applicable for studying Ca2+ signaling by in vitro high-content functional imaging of [Ca2+]i in suspension cells, including but not restricted to human immune cells.
Collapse
Affiliation(s)
- Paul Ritter
- Institute of Medical Biotechnology, Friedrich-Alexander-University Erlangen-Nürnberg, Erlangen, Germany; Erlangen Graduate School in Advanced Optical Technologies (SAOT), Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany
| | - Lydia J Bye
- Illawarra Health and Medical Research Institute (IHMRI), University of Wollongong, Wollongong, Australia
| | - Rocio K Finol-Urdaneta
- Illawarra Health and Medical Research Institute (IHMRI), University of Wollongong, Wollongong, Australia
| | - Christian Lesko
- Institute of Medical Biotechnology, Friedrich-Alexander-University Erlangen-Nürnberg, Erlangen, Germany; Erlangen Graduate School in Advanced Optical Technologies (SAOT), Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany
| | - David J Adams
- Illawarra Health and Medical Research Institute (IHMRI), University of Wollongong, Wollongong, Australia
| | - Oliver Friedrich
- Institute of Medical Biotechnology, Friedrich-Alexander-University Erlangen-Nürnberg, Erlangen, Germany; Erlangen Graduate School in Advanced Optical Technologies (SAOT), Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany
| | - Daniel F Gilbert
- Institute of Medical Biotechnology, Friedrich-Alexander-University Erlangen-Nürnberg, Erlangen, Germany; Erlangen Graduate School in Advanced Optical Technologies (SAOT), Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany.
| |
Collapse
|
3
|
3D Printed Lab-on-a-Chip Platform for Chemical Stimulation and Parallel Analysis of Ion Channel Function. MICROMACHINES 2019; 10:mi10080548. [PMID: 31430884 PMCID: PMC6722671 DOI: 10.3390/mi10080548] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/16/2019] [Revised: 08/06/2019] [Accepted: 08/16/2019] [Indexed: 12/27/2022]
Abstract
Functional imaging has been a widely established method for the assessment of ion channel function in vitro. Conventional infrastructure used for in vitro functional analysis of ion channels is typically proprietary, non-customizable, expensive, and requires a high level of skill to use and maintain. 3D desktop printing, which is employed in the rapid prototyping field, allows for quick engineering of alternatives to conventional imaging infrastructure that are customizable, low cost, and user friendly. Here, we describe an ultra-low-cost microfluidic lab-on-a-chip (LOC) device manufactured using acrylonitrile butadiene styrene (ABS) for in vitro functional imaging of ion channels that can quickly and easily be reconstructed using three-dimensional (3D) desktop printing. The device is light weight (<5 g), small (20 mm × 49 mm), and extremely low cost (<EUR 1). We simulate fluidics within the printed channels and assess the suitability of the engineered chamber to generate homogeneous mixtures during solution exchange. We demonstrate the usability of the 3D printed microfluidic device in a case study using Fluo-4-loaded human embryonal kidney-derived (HEK293) cells, recombinantly expressing the capsaicin receptor, transient receptor potential vanilloid receptor type 1 (TRPV1), as a model system. In the case study, we confirm its applicability to solution exchange for chemical stimulation and parallel functional time-lapse fluorescence microscopy-based calcium imaging. We assess the suitability of ABS for culturing HEK293 cells inside the microfluidic LOC, based on qualitative analysis of microscopic transmission light images of ABS-exposed HEK293 cells and confirm the previously reported biocompatibility of ABS. To highlight the versatility of the 3D printed microfluidic device, we provide an example for multiplication of the shown concept within a 3D printed multichannel microfluidic LOC to be used, for example, in a higher throughput format for parallelized functional analysis of ion channels. While this work focusses on Ca2+ imaging with TRPV1 channels, the device may also be useful for application with other ion channel types and in vitro models.
Collapse
|
4
|
Gilbert DF, Mofrad SA, Friedrich O, Wiest J. Proliferation characteristics of cells cultured under periodic versus static conditions. Cytotechnology 2018; 71:443-452. [PMID: 30515656 DOI: 10.1007/s10616-018-0263-z] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2018] [Accepted: 09/27/2018] [Indexed: 12/13/2022] Open
Abstract
In vitro culture models have become an indispensable tool for assessing a vast variety of biological questions in many scientific fields. However, common in vitro cultures are maintained under static conditions, which do not reflect the in vivo situation and create a non-physiological environment. To assess whether the growth characteristics of cells cultured at pulsed-perfused versus static conditions differ, we observed the growth of differentially cultured cells in vitro by life-cell time-lapse imaging of recombinant HEK293YFPI152L cells, stably expressing yellow fluorescent protein. Cells were grown for ~ 30 h at 37 °C and ambient CO2 concentration in biochips mounted into a custom-designed 3D printed carrier and were imaged at a rate of ten images per hour using a fluorescence microscope with environment control infrastructure. Cells in one chip were maintained under static conditions whereas cells in another chip were recurrently perfused with fresh media. Generated image series were quantitatively analyzed using a custom-modified cell detection software. Imaging data averaged from four biological replicates per culturing condition demonstrate that cells cultured under conventional conditions exhibit an exponential growth rate. In contrast, cells cultured in periodic mode exhibited a non-exponential growth rate. Our data clearly indicate differential growth characteristics of cells cultured under periodic versus static conditions highlighting the impact of the culture conditions on the physiology of cells in vitro.
Collapse
Affiliation(s)
- Daniel F Gilbert
- Institute of Medical Biotechnology, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany. .,Erlangen Graduate School in Advanced Optical Technologies (SAOT), Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany.
| | - Sepideh Abolpour Mofrad
- Institute of Medical Biotechnology, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany.,Erlangen Graduate School in Advanced Optical Technologies (SAOT), Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany
| | - Oliver Friedrich
- Institute of Medical Biotechnology, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany.,Erlangen Graduate School in Advanced Optical Technologies (SAOT), Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany
| | | |
Collapse
|
5
|
Kuenzel K, Mofrad SA, Gilbert DF. Phenotyping Cellular Viability by Functional Analysis of Ion Channels: GlyR-Targeted Screening in NT2-N Cells. Methods Mol Biol 2018; 1601:205-214. [PMID: 28470528 DOI: 10.1007/978-1-4939-6960-9_16] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
Glycine receptor chloride channels (GlyRs) are attractive drug targets for therapeutic intervention and are also more and more recognized in the context of in vitro neurotoxicity and developmental neurotoxicity testing. Assaying the functional properties of GlyR can serve as an indicator of cellular viability and the integrity of the developing and mature central nervous system. Human pluripotent NTERA-2 (NT2) stem cells undergo neuronal differentiation upon stimulation with retinoic acid and express a large variety of neuronal proteins-including GlyR. YFP-I152L, a halide-sensitive variant of yellow fluorescent protein, allows high-throughput fluorescence-based functional analysis of GlyRs in NT2 cells. Here we describe a protocol for phenotyping of cellular viability by functional analysis of GlyR in neuronally differentiated NT2 (NT2-N) cells using YFP-I152L as a reporter of functional integrity of GlyRs. The protocol describes neuronal differentiation of NT2 stem cells, transient transfection of NT2-N cells with YFP-I152L as well as functional imaging and analysis of data from high-content imaging.
Collapse
Affiliation(s)
- Katharina Kuenzel
- Institute of Medical Biotechnology, Friedrich-Alexander-Universität Erlangen-Nürnberg, Paul-Gordan-Str. 3, 91052, Erlangen, Germany.
| | - Sepideh Abolpour Mofrad
- Institute of Medical Biotechnology, Friedrich-Alexander-Universität Erlangen-Nürnberg, Paul-Gordan-Str. 3, 91052, Erlangen, Germany
| | - Daniel F Gilbert
- Friedrich-Alexander University (FAU) Erlangen-Nürnberg, Institute of Medical Biotechnology, Paul-Gordan-Street 3, 91052, Erlangen, Germany
| |
Collapse
|
6
|
Abstract
High-throughput cell viability assays are broadly used in RNAi and small molecule screening experiments to identify compounds that selectively kill cancer cells or as counter screens to exclude the compounds that have a generic effect on cell growth. While there are several assaying techniques available, cellular fitness is often assessed on the basis of one single and often rather indirect physiological indicator. This can lead to inconsistencies and poor correspondence between cell viability screening experiments, conducted under comparable conditions but with different viability indicators. Multiplexing, i.e., the combination of different individual assaying techniques in one experiment and subsequent comparative analysis of multiparametric data can decrease inter-assay variability and increase dataset concordance. Here, we describe a protocol for a multiplexing approach for high-throughput cell viability screening to address the issues encountered in the classical strategy using a single fitness indicator described above. The method combines a biochemical, luminescence-based approach and two fluorescence-based assay types. The biochemical method assesses cellular fitness by quantifying intracellular ATP concentration. Calcein labeling reflects cell fitness through membrane integrity and indirect measurement of ATP-dependent enzymatic esterase activity. Hoechst DNA stain correlates cell fitness with cellular DNA content. The presented multiplexing approach is suitable for low, medium and high-throughput screening and has the potential to decrease inter-assay variability and increase dataset concordance as well as reproducibility of experimental results.
Collapse
|
7
|
Ku TSN, Bernardo S, Walraven CJ, Lee SA. Candidiasis and the impact of flow cytometry on antifungal drug discovery. Expert Opin Drug Discov 2017; 12:1127-1137. [PMID: 28876963 DOI: 10.1080/17460441.2017.1377179] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
INTRODUCTION Invasive candidiasis continues to be associated with significant morbidity and mortality as well as substantial health care costs nationally and globally. One of the contributing factors is the development of resistance to antifungal agents that are already in clinical use. Moreover, there are known treatment limitations with all of the available antifungal agents. Since traditional techniques in novel drug discovery are time consuming, high-throughput screening using flow cytometry presents as a potential tool to identify new antifungal agents that would be useful in the management of these patients. Areas covered: In this review, the authors discuss the use of automated high-throughput screening assays based upon flow cytometry to identify potential antifungals from a library comprised of a large number of bioactive compounds. They also review studies that employed the use of this research methodology that has identified compounds with antifungal activity. Expert opinion: High-throughput screening using flow cytometry has substantially decreased the processing time necessary for screening thousands of compounds, and has helped enhance our understanding of fungal pathogenesis. Indeed, the authors see this technology as a powerful tool to help scientists identify new antifungal agents that can be added to the clinician's arsenal in their fight against invasive candidiasis.
Collapse
Affiliation(s)
- Tsun Sheng N Ku
- a Section of Infectious Diseases , New Mexico VA Health Care System , Albuquerque , NM , USA.,b Division of Infectious Diseases , University of New Mexico Health Science Center , Albuquerque , NM , USA
| | - Stella Bernardo
- a Section of Infectious Diseases , New Mexico VA Health Care System , Albuquerque , NM , USA.,b Division of Infectious Diseases , University of New Mexico Health Science Center , Albuquerque , NM , USA
| | - Carla J Walraven
- c Department of Pharmaceutical Services , University of New Mexico Hospital , Albuquerque , NM , USA
| | - Samuel A Lee
- a Section of Infectious Diseases , New Mexico VA Health Care System , Albuquerque , NM , USA.,b Division of Infectious Diseases , University of New Mexico Health Science Center , Albuquerque , NM , USA
| |
Collapse
|
8
|
Step-by-step guide to building an inexpensive 3D printed motorized positioning stage for automated high-content screening microscopy. Biosens Bioelectron 2016; 92:472-481. [PMID: 27840039 DOI: 10.1016/j.bios.2016.10.078] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2016] [Revised: 10/21/2016] [Accepted: 10/25/2016] [Indexed: 01/16/2023]
Abstract
High-content screening microscopy relies on automation infrastructure that is typically proprietary, non-customizable, costly and requires a high level of skill to use and maintain. The increasing availability of rapid prototyping technology makes it possible to quickly engineer alternatives to conventional automation infrastructure that are low-cost and user-friendly. Here, we describe a 3D printed inexpensive open source and scalable motorized positioning stage for automated high-content screening microscopy and provide detailed step-by-step instructions to re-building the device, including a comprehensive parts list, 3D design files in STEP (Standard for the Exchange of Product model data) and STL (Standard Tessellation Language) format, electronic circuits and wiring diagrams as well as software code. System assembly including 3D printing requires approx. 30h. The fully assembled device is light-weight (1.1kg), small (33×20×8cm) and extremely low-cost (approx. EUR 250). We describe positioning characteristics of the stage, including spatial resolution, accuracy and repeatability, compare imaging data generated with our device to data obtained using a commercially available microplate reader, demonstrate its suitability to high-content microscopy in 96-well high-throughput screening format and validate its applicability to automated functional Cl-- and Ca2+-imaging with recombinant HEK293 cells as a model system. A time-lapse video of the stage during operation and as part of a custom assembled screening robot can be found at https://vimeo.com/158813199.
Collapse
|
9
|
Kuenzel K, Friedrich O, Gilbert DF. A Recombinant Human Pluripotent Stem Cell Line Stably Expressing Halide-Sensitive YFP-I152L for GABAAR and GlyR-Targeted High-Throughput Drug Screening and Toxicity Testing. Front Mol Neurosci 2016; 9:51. [PMID: 27445687 PMCID: PMC4923258 DOI: 10.3389/fnmol.2016.00051] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2016] [Accepted: 06/13/2016] [Indexed: 01/29/2023] Open
Abstract
GABAARs and GlyRs are considered attractive drug targets for therapeutic intervention and are also increasingly recognized in the context of in vitro neurotoxicity (NT) and developmental neurotoxicity (DNT) testing. However, systematic human-specific GABAAR and GlyR-targeted drug screening and toxicity testing is hampered due to lack of appropriate in vitro models that express native GABAARs and GlyRs. We have established a human pluripotent stem cell line (NT2) stably expressing YFP-I152L, a halide-sensitive variant of yellow fluorescent protein (YFP), allowing for fluorescence-based functional analysis of chloride channels. Upon stimulation with retinoic acid, NT2 cells undergo neuronal differentiation and allow pharmacological and toxicological evaluation of native GABAARs and GlyRs at different stages of brain maturation. We applied the cell line in concentration-response experiments with the neurotransmitters GABA and glycine as well as with the drugs strychnine, picrotoxin, fipronil, lindane, bicuculline, and zinc and demonstrate that the established in vitro model is applicable to GABAAR and GlyR-targeted pharmacological and toxicological profiling. We quantified the proportion of GABAAR and GlyR-sensitive cells, respectively, and identified percentages of approximately 20% each within the overall populations, rendering the cells a suitable model for systematic in vitro GABAAR and GlyR-targeted screening in the context of drug development and NT/DNT testing.
Collapse
Affiliation(s)
- Katharina Kuenzel
- Department of Chemical and Biological Engineering, Institute of Medical Biotechnology, Friedrich-Alexander-Universität Erlangen-NürnbergErlangen, Germany; Erlangen Graduate School in Advanced Optical Technologies, Friedrich-Alexander-Universität Erlangen-NürnbergErlangen, Germany
| | - Oliver Friedrich
- Department of Chemical and Biological Engineering, Institute of Medical Biotechnology, Friedrich-Alexander-Universität Erlangen-NürnbergErlangen, Germany; Erlangen Graduate School in Advanced Optical Technologies, Friedrich-Alexander-Universität Erlangen-NürnbergErlangen, Germany
| | - Daniel F Gilbert
- Department of Chemical and Biological Engineering, Institute of Medical Biotechnology, Friedrich-Alexander-Universität Erlangen-NürnbergErlangen, Germany; Erlangen Graduate School in Advanced Optical Technologies, Friedrich-Alexander-Universität Erlangen-NürnbergErlangen, Germany
| |
Collapse
|
10
|
Arosio D, Ratto GM. Twenty years of fluorescence imaging of intracellular chloride. Front Cell Neurosci 2014; 8:258. [PMID: 25221475 PMCID: PMC4148895 DOI: 10.3389/fncel.2014.00258] [Citation(s) in RCA: 70] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2014] [Accepted: 08/12/2014] [Indexed: 11/23/2022] Open
Abstract
Chloride homeostasis has a pivotal role in controlling neuronal excitability in the adult brain and during development. The intracellular concentration of chloride is regulated by the dynamic equilibrium between passive fluxes through membrane conductances and the active transport mediated by importers and exporters. In cortical neurons, chloride fluxes are coupled to network activity by the opening of the ionotropic GABAA receptors that provides a direct link between the activity of interneurons and chloride fluxes. These molecular mechanisms are not evenly distributed and regulated over the neuron surface and this fact can lead to a compartmentalized control of the intracellular concentration of chloride. The inhibitory drive provided by the activity of the GABAA receptors depends on the direction and strength of the associated currents, which are ultimately dictated by the gradient of chloride, the main charge carrier flowing through the GABAA channel. Thus, the intracellular distribution of chloride determines the local strength of ionotropic inhibition and influences the interaction between converging excitation and inhibition. The importance of chloride regulation is also underlined by its involvement in several brain pathologies, including epilepsy and disorders of the autistic spectra. The full comprehension of the physiological meaning of GABAergic activity on neurons requires the measurement of the spatiotemporal dynamics of chloride fluxes across the membrane. Nowadays, there are several available tools for the task, and both synthetic and genetically encoded indicators have been successfully used for chloride imaging. Here, we will review the available sensors analyzing their properties and outlining desirable future developments.
Collapse
Affiliation(s)
- Daniele Arosio
- Institute of Biophysics, National Research Council and Bruno Kessler Foundation Trento, Italy ; Centre for Integrative Biology, University of Trento Trento, Italy
| | - Gian Michele Ratto
- Nanoscience Institute, National Research Council of Italy Pisa, Italy ; NEST, Scuola Normale Superiore Pisa, Italy
| |
Collapse
|
11
|
Quah BJC, Wijesundara DK, Ranasinghe C, Parish CR. The use of fluorescent target arrays for assessment of T cell responses in vivo. J Vis Exp 2014:e51627. [PMID: 24998253 DOI: 10.3791/51627] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/14/2023] Open
Abstract
The ability to monitor T cell responses in vivo is important for the development of our understanding of the immune response and the design of immunotherapies. Here we describe the use of fluorescent target array (FTA) technology, which utilizes vital dyes such as carboxyfluorescein succinimidyl ester (CFSE), violet laser excitable dyes (CellTrace Violet: CTV) and red laser excitable dyes (Cell Proliferation Dye eFluor 670: CPD) to combinatorially label mouse lymphocytes into > 250 discernable fluorescent cell clusters. Cell clusters within these FTAs can be pulsed with major histocompatibility (MHC) class-I and MHC class-II binding peptides and thereby act as target cells for CD8(+) and CD4(+) T cells, respectively. These FTA cells remain viable and fully functional, and can therefore be administered into mice to allow assessment of CD8(+) T cell-mediated killing of FTA target cells and CD4(+) T cell-meditated help of FTA B cell target cells in real time in vivo by flow cytometry. Since > 250 target cells can be assessed at once, the technique allows the monitoring of T cell responses against several antigen epitopes at several concentrations and in multiple replicates. As such, the technique can measure T cell responses at both a quantitative (e.g. the cumulative magnitude of the response) and a qualitative (e.g. functional avidity and epitope-cross reactivity of the response) level. Herein, we describe how these FTAs are constructed and give an example of how they can be applied to assess T cell responses induced by a recombinant pox virus vaccine.
Collapse
Affiliation(s)
- Benjamin J C Quah
- Department of Immunology, John Curtin School of Medical Research, Australian National University;
| | - Danushka K Wijesundara
- Department of Immunology, John Curtin School of Medical Research, Australian National University
| | - Charani Ranasinghe
- Department of Immunology, John Curtin School of Medical Research, Australian National University
| | - Christopher R Parish
- Department of Immunology, John Curtin School of Medical Research, Australian National University
| |
Collapse
|
12
|
Kilgore JA, Dolman NJ, Davidson MW. A review of reagents for fluorescence microscopy of cellular compartments and structures, Part III: reagents for actin, tubulin, cellular membranes, and whole cell and cytoplasm. ACTA ACUST UNITED AC 2014; 67:12.32.1-12.32.17. [PMID: 24510770 DOI: 10.1002/0471142956.cy1232s67] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Abstract
Non-antibody commercial fluorescent reagents for imaging of cytoskeletal structures have been limited primarily to tubulin and actin, with the main factor in choice based mainly on whether cells are live or fixed and permeabilized. A wider range of options exist for cell membrane dyes, and the choice of reagent primarily depends on the preferred localization in the cell (i.e., all membranes or only the plasma membrane) and usage (i.e., whether the protocol involves fixation and permeabilization). For whole-cell or cytoplasmic imaging, the choice of reagent is determined mostly by the length of time that the cells need to be visualized (hours or days) and by fixation status. Presented here is a discussion on choosing commercially available reagents for these cellular structures, with an emphasis on use for microscopic imaging, with a featured reagent for each structure, a recommended protocol, troubleshooting guide, and example image.
Collapse
Affiliation(s)
- Jason A Kilgore
- Molecular Probes Labeling and Detection, Life Technologies, Eugene, Oregon
| | - Nick J Dolman
- Molecular Probes Labeling and Detection, Life Technologies, Eugene, Oregon
| | - Michael W Davidson
- National High Magnetic Field Laboratory and Department of Biological Science, Florida State University, Tallahassee, Florida
| |
Collapse
|
13
|
Talwar S, Lynch JW, Gilbert DF. Fluorescence-based high-throughput functional profiling of ligand-gated ion channels at the level of single cells. PLoS One 2013; 8:e58479. [PMID: 23520514 PMCID: PMC3592791 DOI: 10.1371/journal.pone.0058479] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2012] [Accepted: 02/06/2013] [Indexed: 12/26/2022] Open
Abstract
Ion channels are involved in many physiological processes and are attractive targets for therapeutic intervention. Their functional properties vary according to their subunit composition, which in turn varies in a developmental and tissue-specific manner and as a consequence of pathophysiological events. Understanding this diversity requires functional analysis of ion channel properties in large numbers of individual cells. Functional characterisation of ligand-gated channels involves quantitating agonist and drug dose-response relationships using electrophysiological or fluorescence-based techniques. Electrophysiology is limited by low throughput and high-throughput fluorescence-based functional evaluation generally does not enable the characterization of the functional properties of each individual cell. Here we describe a fluorescence-based assay that characterizes functional channel properties at single cell resolution in high throughput mode. It is based on progressive receptor activation and iterative fluorescence imaging and delivers >100 dose-responses in a single well of a 384-well plate, using α1-3 homomeric and αβ heteromeric glycine receptor (GlyR) chloride channels as a model system. We applied this assay with transiently transfected HEK293 cells co-expressing halide-sensitive yellow fluorescent protein and different GlyR subunit combinations. Glycine EC50 values of different GlyR isoforms were highly correlated with published electrophysiological data and confirm previously reported pharmacological profiles for the GlyR inhibitors, picrotoxin, strychnine and lindane. We show that inter and intra well variability is low and that clustering of functional phenotypes permits identification of drugs with subunit-specific pharmacological profiles. As this method dramatically improves the efficiency with which ion channel populations can be characterized in the context of cellular heterogeneity, it should facilitate systems-level analysis of ion channel properties in health and disease and the discovery of therapeutics to reverse pathological alterations.
Collapse
Affiliation(s)
- Sahil Talwar
- Queensland Brain Institute, The University of Queensland, Brisbane, Queensland, Australia
| | - Joseph W. Lynch
- Queensland Brain Institute, The University of Queensland, Brisbane, Queensland, Australia
- School of Biomedical Sciences, The University of Queensland, Brisbane, Queensland, Australia
| | - Daniel F. Gilbert
- Queensland Brain Institute, The University of Queensland, Brisbane, Queensland, Australia
- Institute of Medical Biotechnology, Friedrich-Alexander-University Erlangen-Nuremberg, Erlangen, Germany
- * E-mail:
| |
Collapse
|
14
|
Quah BJC, Wijesundara DK, Ranasinghe C, Parish CR. Fluorescent target array T helper assay: a multiplex flow cytometry assay to measure antigen-specific CD4+ T cell-mediated B cell help in vivo. J Immunol Methods 2012; 387:181-90. [PMID: 23123200 DOI: 10.1016/j.jim.2012.10.013] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2012] [Revised: 10/18/2012] [Accepted: 10/22/2012] [Indexed: 12/24/2022]
Abstract
CD4(+) T cells play a central role in regulating the immune response. Their effector function is commonly assessed by their capacity to secrete cytokines detected by ELISPOT and intracellular cytokine staining. However, one aspect of their effector function that is often overlooked is their ability to help activation of cognate B cells directly, a process that is initiated through the engagement of their T cell-receptor (TCR) with cognate peptide presented on major histocompatibility complex class II (MHC-II) molecules by B cells. Here we report a method to monitor CD4(+) T cell-mediated B cell help in vivo using a multiplex high throughput assay. This assay utilizes a fluorescent target array (FTA), which is composed of lymphocytes labeled with numerous (>200) unique fluorescence signatures that can be delineated in a single recipient animal based on combination labeling with the three vital dyes carboxyfluorescein diacetate succinimidyl ester (CFSE), CellTrace Violet (CTV) and Cell Proliferation Dye eFluor 670 (CPD). By pulsing different B cell populations in a FTA with titrated amounts of cognate MHC-II binding peptides, CD4(+) T cell help could be assessed by measuring induction of the B cell activation markers CD69 and CD44 by antibody labeling and flow cytometry. We call this the "FTA T helper assay", and have found it to be a robust and sensitive assay to measure CD4(+) T cell helper activity across a multitude of peptide-pulsed B "target" cells in real time in vivo. Furthermore, the technique can be used simultaneously with the FTA killing assay that measures cytotoxic T cell function, to provide a comprehensive tool for measuring both CD4(+) and CD8(+) T cell activity during an immune response in vivo.
Collapse
Affiliation(s)
- Benjamin J C Quah
- Department of Immunology, John Curtin School of Medical Research, Australian National University, Canberra, ACT 2601, Australia.
| | | | | | | |
Collapse
|
15
|
Quah BJC, Wijesundara DK, Ranasinghe C, Parish CR. Fluorescent target array killing assay: A multiplex cytotoxic T-cell assay to measure detailed T-cell antigen specificity and avidity in vivo. Cytometry A 2012; 81:679-90. [DOI: 10.1002/cyto.a.22084] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2012] [Revised: 04/20/2012] [Accepted: 05/23/2012] [Indexed: 11/10/2022]
|
16
|
Trowitzsch S, Klumpp M, Thoma R, Carralot JP, Berger I. Light it up: highly efficient multigene delivery in mammalian cells. Bioessays 2011; 33:946-55. [PMID: 22002169 DOI: 10.1002/bies.201100109] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
Multigene delivery and expression systems are emerging as key technologies for many applications in contemporary biology. We have developed new methods for multigene delivery and expression in eukaryotic hosts for a variety of applications, including production of protein complexes for structural biology and drug development, provision of multicomponent protein biologics, and cell-based assays. We implemented tandem recombineering to facilitate rapid generation of multicomponent gene expression constructs for efficient transformation of mammalian cells, resulting in homogenous cell populations. Analysis of multiple parameters in living cells may require co-expression of fluorescently tagged sensors simultaneously in a single cell, at defined and ideally controlled ratios. Our method enables such applications by overcoming currently limiting challenges. Here, we review recent multigene delivery and expression strategies and their exploitation in mammalian cells. We discuss applications in drug discovery assays, interaction studies, and biologics production, which may benefit in the future from our novel approach.
Collapse
|
17
|
Green Fluorescent Protein-Based Chloride Ion Sensors for In Vivo Imaging. FLUORESCENT PROTEINS II 2011. [DOI: 10.1007/4243_2011_27] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
|
18
|
Abstract
Hyperekplexia is a rare, but potentially fatal, neuromotor disorder characterized by exaggerated startle reflexes and hypertonia in response to sudden, unexpected auditory or tactile stimuli. This disorder is primarily caused by inherited mutations in the genes encoding the glycine receptor (GlyR) alpha1 subunit (GLRA1) and the presynaptic glycine transporter GlyT2 (SLC6A5). In this study, systematic DNA sequencing of GLRA1 in 88 new unrelated human hyperekplexia patients revealed 19 sequence variants in 30 index cases, of which 21 cases were inherited in recessive or compound heterozygote modes. This indicates that recessive hyperekplexia is far more prevalent than previous estimates. From the 19 GLRA1 sequence variants, we have investigated the functional effects of 11 novel and 2 recurrent mutations. The expression levels and functional properties of these hyperekplexia mutants were analyzed using a high-content imaging system and patch-clamp electrophysiology. When expressed in HEK293 cells, either as homomeric alpha1 or heteromeric alpha1beta GlyRs, subcellular localization defects were the major mechanism underlying recessive mutations. However, mutants without trafficking defects typically showed alterations in the glycine sensitivity suggestive of disrupted receptor function. This study also reports the first hyperekplexia mutation associated with a GlyR leak conductance, suggesting tonic channel opening as a new mechanism in neuronal ligand-gated ion channels.
Collapse
|
19
|
Bregestovski P, Waseem T, Mukhtarov M. Genetically encoded optical sensors for monitoring of intracellular chloride and chloride-selective channel activity. Front Mol Neurosci 2009; 2:15. [PMID: 20057911 PMCID: PMC2802328 DOI: 10.3389/neuro.02.015.2009] [Citation(s) in RCA: 62] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2009] [Accepted: 08/28/2009] [Indexed: 12/31/2022] Open
Abstract
This review briefly discusses the main approaches for monitoring chloride (Cl−), the most abundant physiological anion. Noninvasive monitoring of intracellular Cl− ([Cl−]i) is a challenging task owing to two main difficulties: (i) the low transmembrane ratio for Cl−, approximately 10:1; and (ii) the small driving force for Cl−, as the Cl− reversal potential (ECl) is usually close to the resting potential of the cells. Thus, for reliable monitoring of intracellular Cl−, one has to use highly sensitive probes. From several methods for intracellular Cl− analysis, genetically encoded chloride indicators represent the most promising tools. Recent achievements in the development of genetically encoded chloride probes are based on the fact that yellow fluorescent protein (YFP) exhibits Cl−-sensitivity. YFP-based probes have been successfully used for quantitative analysis of Cl− transport in different cells and for high-throughput screening of modulators of Cl−-selective channels. Development of a ratiometric genetically encoded probe, Clomeleon, has provided a tool for noninvasive estimation of intracellular Cl− concentrations. While the sensitivity of this protein to Cl− is low (EC50 about 160 mM), it has been successfully used for monitoring intracellular Cl− in different cell types. Recently a CFP–YFP-based probe with a relatively high sensitivity to Cl− (EC50 about 30 mM) has been developed. This construct, termed Cl-Sensor, allows ratiometric monitoring using the fluorescence excitation ratio. Of particular interest are genetically encoded probes for monitoring of ion channel distribution and activity. A new molecular probe has been constructed by introducing into the cytoplasmic domain of the Cl−-selective glycine receptor (GlyR) channel the CFP–YFP-based Cl-Sensor. This construct, termed BioSensor-GlyR, has been successfully expressed in cell lines. The new genetically encoded chloride probes offer means of screening pharmacological agents, analysis of Cl− homeostasis and functions of Cl−-selective channels under different physiological and pathological conditions.
Collapse
|
20
|
Prowse ABJ, Wilson J, Osborne GW, Gray PP, Wolvetang EJ. Multiplexed staining of live human embryonic stem cells for flow cytometric analysis of pluripotency markers. Stem Cells Dev 2009; 18:1135-40. [PMID: 19397457 DOI: 10.1089/scd.2009.0080] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023] Open
Abstract
Use of flow cytometry to detect pluripotency markers on or in human embryonic stem cells (hESCs) is a powerful analytical tool. However, current staining methodologies for high-content analysis of large numbers of samples utilize large quantities of primary and secondary antibodies, are time consuming, and may suffer from sample-to-sample variability. To circumvent these issues, we have developed a reproducible, quick, and cost-effective method of staining 12 populations of hESCs grown under different conditions by labeling each with a unique optical signature (UOS). The UOS for each population is achieved by combining different combinations and concentrations of 3 esterase activated, live cell, fluorescent indicators. The individually stained populations are then combined and an aliquot of the hESC samples stained for pluripotency or other markers of interest in the far-red region of the spectrum. Based on the unique fluorescent intensity and emission wavelengths of each population, the characteristics of each population are decoded in software after flow cytometric analysis. We have validated both our staining procedure and decoding methods by mixing populations of differentiated and undifferentiated hESCs and successfully quantifying differences in the pluripotency markers SSEA-4, Tra-1-60, GCTM2, and CD9 between the 12 different populations. Our multiplexing approach allows for the addition of internal controls and reduces sample-to-sample variation, while offering a significant reduction in time and reagent consumption. We anticipate that this method will be of great benefit to laboratories conducting high-content flow cytometric analysis of hESCs.
Collapse
Affiliation(s)
- Andrew B J Prowse
- Australian Institute for Bioengineering and Nanotechnology, The University of Queensland, Brisbane, Queensland 4072, Australia
| | | | | | | | | |
Collapse
|
21
|
Gilbert DF, Islam R, Lynagh T, Lynch JW, Webb TI. High Throughput Techniques for Discovering New Glycine Receptor Modulators and their Binding Sites. Front Mol Neurosci 2009; 2:17. [PMID: 19949449 PMCID: PMC2782790 DOI: 10.3389/neuro.02.017.2009] [Citation(s) in RCA: 29] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2009] [Accepted: 09/27/2009] [Indexed: 11/13/2022] Open
Abstract
The inhibitory glycine receptor (GlyR) is a member of the Cys-loop receptor family that mediates inhibitory neurotransmission in the central nervous system. These receptors are emerging as potential drug targets for inflammatory pain, immunomodulation, spasticity and epilepsy. Antagonists that specifically inhibit particular GlyR isoforms are also required as pharmacological probes for elucidating the roles of particular GlyR isoforms in health and disease. Although a substantial number of both positive and negative GlyR modulators have been identified, very few of these are specific for the GlyR over other receptor types. Thus, the potential of known compounds as either therapeutic leads or pharmacological probes is limited. It is therefore surprising that there have been few published studies describing attempts to discover novel GlyR isoform-specific modulators. The first aim of this review is to consider various methods for efficiently screening compounds against these receptors. We conclude that an anion sensitive yellow fluorescent protein is optimal for primary screening and that automated electrophysiology of cells stably expressing GlyRs is useful for confirming hits and quantitating the actions of identified compounds. The second aim of this review is to demonstrate how these techniques are used in our laboratory for the purpose of both discovering novel GlyR-active compounds and characterizing their binding sites. We also describe a reliable, cost effective method for transfecting HEK293 cells in single wells of a 384-well plate using nanogram quantities of plasmid DNA.
Collapse
Affiliation(s)
- Daniel F Gilbert
- Queensland Brain Institute, The University of Queensland Brisbane, QLD, Australia
| | | | | | | | | |
Collapse
|
22
|
Gilbert DF, Meinhof T, Pepperkok R, Runz H. DetecTiff: a novel image analysis routine for high-content screening microscopy. ACTA ACUST UNITED AC 2009; 14:944-55. [PMID: 19641223 DOI: 10.1177/1087057109339523] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
In this article, the authors describe the image analysis software DetecTiff, which allows fully automated object recognition and quantification from digital images. The core module of the LabView-based routine is an algorithm for structure recognition that employs intensity thresholding and size-dependent particle filtering from microscopic images in an iterative manner. Detected structures are converted into templates, which are used for quantitative image analysis. DetecTiff enables processing of multiple detection channels and provides functions for template organization and fast interpretation of acquired data. The authors demonstrate the applicability of DetecTiff for automated analysis of cellular uptake of fluorescence-labeled low-density lipoproteins as well as diverse other image data sets from a variety of biomedical applications. Moreover, the performance of DetecTiff is compared with preexisting image analysis tools. The results show that DetecTiff can be applied with high consistency for automated quantitative analysis of image data (e.g., from large-scale functional RNAi screening projects).
Collapse
|
23
|
|