1
|
Wlodkowic D, Jansen M. High-throughput screening paradigms in ecotoxicity testing: Emerging prospects and ongoing challenges. CHEMOSPHERE 2022; 307:135929. [PMID: 35944679 DOI: 10.1016/j.chemosphere.2022.135929] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/13/2022] [Revised: 06/09/2022] [Accepted: 07/31/2022] [Indexed: 06/15/2023]
Abstract
The rapidly increasing number of new production chemicals coupled with stringent implementation of global chemical management programs necessities a paradigm shift towards boarder uses of low-cost and high-throughput ecotoxicity testing strategies as well as deeper understanding of cellular and sub-cellular mechanisms of ecotoxicity that can be used in effective risk assessment. The latter will require automated acquisition of biological data, new capabilities for big data analysis as well as computational simulations capable of translating new data into in vivo relevance. However, very few efforts have been so far devoted into the development of automated bioanalytical systems in ecotoxicology. This is in stark contrast to standardized and high-throughput chemical screening and prioritization routines found in modern drug discovery pipelines. As a result, the high-throughput and high-content data acquisition in ecotoxicology is still in its infancy with limited examples focused on cell-free and cell-based assays. In this work we outline recent developments and emerging prospects of high-throughput bioanalytical approaches in ecotoxicology that reach beyond in vitro biotests. We discuss future importance of automated quantitative data acquisition for cell-free, cell-based as well as developments in phytotoxicity and in vivo biotests utilizing small aquatic model organisms. We also discuss recent innovations such as organs-on-a-chip technologies and existing challenges for emerging high-throughput ecotoxicity testing strategies. Lastly, we provide seminal examples of the small number of successful high-throughput implementations that have been employed in prioritization of chemicals and accelerated environmental risk assessment.
Collapse
Affiliation(s)
- Donald Wlodkowic
- The Neurotox Lab, School of Science, RMIT University, Melbourne, VIC, 3083, Australia.
| | - Marcus Jansen
- LemnaTec GmbH, Nerscheider Weg 170, 52076, Aachen, Germany
| |
Collapse
|
2
|
Wlodkowic D, Czerw A, Karakiewicz B, Deptała A. Recent progress in cytometric technologies and their applications in ecotoxicology and environmental risk assessment. Cytometry A 2021; 101:203-219. [PMID: 34652065 DOI: 10.1002/cyto.a.24508] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2021] [Revised: 09/20/2021] [Accepted: 09/30/2021] [Indexed: 12/14/2022]
Abstract
Environmental toxicology focuses on identifying and predicting impact of potentially toxic anthropogenic chemicals on biosphere at various levels of biological organization. Presently there is a significant drive to gain deeper understanding of cellular and sub-cellular mechanisms of ecotoxicity. Most notable is increased focus on elucidation of cellular-response networks, interactomes, and greater implementation of cell-based biotests using high-throughput procedures, while at the same time decreasing the reliance on standard animal models used in ecotoxicity testing. This is aimed at discovery and interpretation of molecular pathways of ecotoxicity at large scale. In this regard, the applications of cytometry are perhaps one of the most fundamental prospective analytical tools for the next generation and high-throughput ecotoxicology research. The diversity of this modern technology spans flow, laser-scanning, imaging, and more recently, Raman as well as mass cytometry. The cornerstone advantages of cytometry include the possibility of multi-parameter measurements, gating and rapid analysis. Cytometry overcomes, thus, limitations of traditional bulk techniques such as spectrophotometry or gel-based techniques that average the results from pooled cell populations or small model organisms. Novel technologies such as cell imaging in flow, laser scanning cytometry, as well as mass cytometry provide innovative and tremendously powerful capabilities to analyze cells, tissues as well as to perform in situ analysis of small model organisms. In this review, we outline cytometry as a tremendously diverse field that is still vastly underutilized and often largely unknown in environmental sciences. The main motivation of this work is to highlight the potential and wide-reaching applications of cytometry in ecotoxicology, guide environmental scientists in the technological aspects as well as popularize its broader adoption in environmental risk assessment.
Collapse
Affiliation(s)
- Donald Wlodkowic
- The Neurotox Lab, School of Science, RMIT University, Melbourne, Victoria, Australia
| | - Aleksandra Czerw
- Department of Health Economics and Medical Law, Faculty of Health Sciences, Medical University of Warsaw, Warsaw, Poland
| | - Beata Karakiewicz
- Subdepartment of Social Medicine and Public Health, Department of Social Medicine, Pomeranian Medical University, Szczecin, Poland
| | - Andrzej Deptała
- Department of Cancer Prevention. Faculty of Health Sciences, Medical University of Warsaw, Warsaw, Poland
| |
Collapse
|
3
|
Wlodkowic D, Campana O. Toward High-Throughput Fish Embryo Toxicity Tests in Aquatic Toxicology. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2021; 55:3505-3513. [PMID: 33656853 DOI: 10.1021/acs.est.0c07688] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Addressing the shift from classical animal testing to high-throughput in vitro and/or simplified in vivo proxy models has been defined as one of the upcoming challenges in aquatic toxicology. In this regard, the fish embryo toxicity test (FET) has gained significant popularity and wide standardization as one of the sensitive alternative approaches to acute fish toxicity tests in chemical risk assessment and water quality evaluation. Nevertheless, despite the growing regulatory acceptance, the actual manipulation, dispensing, and analysis of living fish embryos remains very labor intensive. Moreover, the FET is commonly performed in plastic multiwell plates under static or semistatic conditions, potentially inadequate for toxicity assessment of some organic, easily degradable or highly adsorptive toxicants. Recent technological advances in the field of mechatronics, fluidics and digital vision systems demonstrate promising future opportunities for automation of many analytical stages in embryo toxicity testing. In this review, we highlight emerging advances in fluidic and laboratory automation systems that can prospectively enable high-throughput FET testing (HT-FET) akin to pipelines commonly found in in vitro drug discovery pipelines. We also outline the existing challenges, barriers to future development and provide an outlook of ground-breaking fluidic technologies in embryo toxicity testing.
Collapse
Affiliation(s)
- Donald Wlodkowic
- School of Science, RMIT University, Melbourne, Victoria 3083, Australia
| | - Olivia Campana
- University of Cadiz, INMAR, Puerto Real, Cadiz 11512, Spain
| |
Collapse
|
4
|
Edible additive effects on zebrafish cardiovascular functionality with hydrodynamic assessment. Sci Rep 2020; 10:16243. [PMID: 33004964 PMCID: PMC7530699 DOI: 10.1038/s41598-020-73455-9] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2020] [Accepted: 08/19/2020] [Indexed: 01/17/2023] Open
Abstract
Food coloring is often used as a coloring agent in foods, medicines and cosmetics, and it was reported to have certain carcinogenic and mutagenic effects in living organisms. Investigation of physiological parameters using zebrafish is a promising methodology to understand disease biology and drug toxicity for various drug discovery on humans. Zebrafish (Danio rerio) is a well-acknowledged model organism with combining assets such as body transparency, small size, low cost of cultivation, and high genetic homology with humans and is used as a specimen tool for the in-vivo throughput screening approach. In addition, recent advances in microfluidics show a promising alternative for zebrafish manipulation in terms of drug administration and extensive imaging capability. This pilot work highlighted the design and development of a microfluidic detection platform for zebrafish larvae through investigating the effects of food coloring on cardiovascular functionality and pectoral fin swing ability. The zebrafish embryos were exposed to the Cochineal Red and Brilliant Blue FCF pigment solution in a concentration of (0.02‰, 0.2‰) cultured in the laboratory from the embryo stage to hatching and development until 9 days post fertilization (d.p.f.). In addition, zebrafish swimming behaviors in terms of pectoral fin beating towards the toxicity screening were further studied by visualizing the induced flow field. It was evidenced that Cochineal Red pigment at a concentration of 0.2‰ not only significantly affected the zebrafish pectoral fin swing behavior, but also significantly increased the heart rate of juvenile fish. The higher concentration of Brilliant Blue FCF pigment (0.2%) increased heart rate during early embryonic stages of zebrafish. However, zebrafish exposed to food coloring did not show any significant changes in cardiac output. The applications of this proposed platform can be further extended towards observing the neurobiological/hydrodynamic behaviors of zebrafish larvae for practical applications in drug tests.
Collapse
|
5
|
Towards High-Throughput Chemobehavioural Phenomics in Neuropsychiatric Drug Discovery. Mar Drugs 2019; 17:md17060340. [PMID: 31174272 PMCID: PMC6627923 DOI: 10.3390/md17060340] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2019] [Revised: 05/19/2019] [Accepted: 06/01/2019] [Indexed: 12/11/2022] Open
Abstract
Identifying novel marine-derived neuroactive chemicals with therapeutic potential is difficult due to inherent complexities of the central nervous system (CNS), our limited understanding of the molecular foundations of neuro-psychiatric conditions, as well as the limited applications of effective high-throughput screening models that recapitulate functionalities of the intact CNS. Furthermore, nearly all neuro-modulating chemicals exhibit poorly characterized pleiotropic activities often referred to as polypharmacology. The latter renders conventional target-based in vitro screening approaches very difficult to accomplish. In this context, chemobehavioural phenotyping using innovative small organism models such as planarians and zebrafish represent powerful and highly integrative approaches to study the impact of new chemicals on central and peripheral nervous systems. In contrast to in vitro bioassays aimed predominantly at identification of chemicals acting on single targets, phenotypic chemobehavioural analysis allows for complex multi-target interactions to occur in combination with studies of polypharmacological effects of chemicals in a context of functional and intact milieu of the whole organism. In this review, we will outline recent advances in high-throughput chemobehavioural phenotyping and provide a future outlook on how those innovative methods can be utilized for rapidly screening and characterizing marine-derived compounds with prospective applications in neuropharmacology and psychosomatic medicine.
Collapse
|
6
|
A Bubble-Free Microfluidic Device for Easy-to-Operate Immobilization, Culturing and Monitoring of Zebrafish Embryos. MICROMACHINES 2019; 10:mi10030168. [PMID: 30823425 PMCID: PMC6470713 DOI: 10.3390/mi10030168] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/28/2019] [Revised: 02/22/2019] [Accepted: 02/25/2019] [Indexed: 01/10/2023]
Abstract
The development of miniaturized devices for studying zebrafish embryos has been limited due to complicated fabrication and operation processes. Here, we reported on a microfluidic device that enabled the capture and culture of zebrafish embryos and real-time monitoring of dynamic embryonic development. The device was simply fabricated by bonding two layers of polydimethylsiloxane (PDMS) structures replicated from three-dimensional (3D) printed reusable molds onto a flat glass substrate. Embryos were easily loaded into the device with a pipette, docked in traps by gravity, and then retained in traps with hydrodynamic forces for long-term culturing. A degassing chamber bonded on top was used to remove air bubbles from the embryo-culturing channel and traps so that any embryo movement caused by air bubbles was eliminated during live imaging. Computational fluid dynamics simulations suggested this embryo-trapping and -retention regime to exert low shear stress on the immobilized embryos. Monitoring of the zebrafish embryogenesis over 20 h during the early stages successfully verified the performance of the microfluidic device for culturing the immobilized zebrafish embryos. Therefore, this rapid-prototyping, low-cost and easy-to-operate microfluidic device offers a promising platform for the long-term culturing of immobilized zebrafish embryos under continuous medium perfusion and the high-quality screening of the developmental dynamics.
Collapse
|
7
|
Cartlidge R, Wlodkowic D. Rapid Fabrication of Chip‐Based Physiometers for Neurobehavioral Toxicity Assays Using Rotifers
Brachionus calyciflorus. Cytometry A 2018; 93:837-847. [DOI: 10.1002/cyto.a.23510] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2018] [Revised: 05/23/2018] [Accepted: 05/24/2018] [Indexed: 02/06/2023]
Affiliation(s)
- Rhys Cartlidge
- The Phenomics Laboratory School of Science, RMIT University Melbourne Victoria Australia
| | - Donald Wlodkowic
- The Phenomics Laboratory School of Science, RMIT University Melbourne Victoria Australia
| |
Collapse
|
8
|
Campana O, Wlodkowic D. Ecotoxicology Goes on a Chip: Embracing Miniaturized Bioanalysis in Aquatic Risk Assessment. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2018; 52:932-946. [PMID: 29284083 DOI: 10.1021/acs.est.7b03370] [Citation(s) in RCA: 30] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
Biological and environmental sciences are, more than ever, becoming highly dependent on technological and multidisciplinary approaches that warrant advanced analytical capabilities. Microfluidic lab-on-a-chip technologies are perhaps one the most groundbreaking offshoots of bioengineering, enabling design of an entirely new generation of bioanalytical instrumentation. They represent a unique approach to combine microscale engineering and physics with specific biological questions, providing technological advances that allow for fundamentally new capabilities in the spatiotemporal analysis of molecules, cells, tissues, and even small metazoan organisms. While these miniaturized analytical technologies experience an explosive growth worldwide, with a substantial promise of a direct impact on biosciences, it seems that lab-on-a-chip systems have so far escaped the attention of aquatic ecotoxicologists. In this Critical Review, potential applications of the currently existing and emerging chip-based technologies for aquatic ecotoxicology and water quality monitoring are highlighted. We also offer suggestions on how aquatic ecotoxicology can benefit from adoption of microfluidic lab-on-a-chip devices for accelerated bioanalysis.
Collapse
Affiliation(s)
- Olivia Campana
- Instituto de Ciencias Marinas de Andalucía, CSIC , Puerto Real, 11519, Spain
| | - Donald Wlodkowic
- School of Science, RMIT University , Melbourne, Victoria 3083, Australia
| |
Collapse
|
9
|
Huang Y, Campana O, Wlodkowic D. A Millifluidic System for Analysis of Daphnia magna Locomotory Responses to Water-born Toxicants. Sci Rep 2017; 7:17603. [PMID: 29242636 PMCID: PMC5730546 DOI: 10.1038/s41598-017-17892-z] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2017] [Accepted: 12/01/2017] [Indexed: 12/23/2022] Open
Abstract
Aquatic toxicity testing in environmental monitoring and chemical risk assessment is critical to assess water quality for human use as well as predict impact of pollutants on ecosystems. In recent years, studies have increasingly focused on the relevance of sub-lethal effects of environmental contaminants. Sub-lethal toxicity endpoints such as behavioural responses are highly integrative and have distinct benefits for assessing water quality because they occur rapidly and thus can be used to sense the presence of toxicants. Our work describes a Lab-on-a-Chip system for the automated analysis of freshwater cladoceran Daphnia magna locomotory responses to water-born toxicants. The design combines a Lab-on-a-Chip system for Daphnia sp. culture under perfusion with time-resolved videomicroscopy and software tracking locomotory activity of multiple specimens. The application of the system to analyse the swimming behaviour of water fleas exposed to different concentrations of water-born toxicants demonstrated that Lab-on-a-Chip devices can become important research tools for behavioural ecotoxicology and water quality biomonitoring.
Collapse
Affiliation(s)
- Yushi Huang
- School of Science, RMIT University, Melbourne, VIC, Australia
| | - Olivia Campana
- Instituto de Ciencias Marinas de Andalucia, CSIC, Cadiz, Spain
| | - Donald Wlodkowic
- School of Science, RMIT University, Melbourne, VIC, Australia. .,Centre for Additive Manufacturing, School of Engineering, RMIT University, Melbourne, VIC 3083, Australia.
| |
Collapse
|
10
|
Use of genetically encoded, light-gated ion translocators to control tumorigenesis. Oncotarget 2017; 7:19575-88. [PMID: 26988909 PMCID: PMC4991402 DOI: 10.18632/oncotarget.8036] [Citation(s) in RCA: 61] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2015] [Accepted: 02/11/2016] [Indexed: 01/01/2023] Open
Abstract
It has long been known that the resting potential of tumor cells is depolarized relative to their normal counterparts. More recent work has provided evidence that resting potential is not just a readout of cell state: it regulates cell behavior as well. Thus, the ability to control resting potential in vivo would provide a powerful new tool for the study and treatment of tumors, a tool capable of revealing living-state physiological information impossible to obtain using molecular tools applied to isolated cell components. Here we describe the first use of optogenetics to manipulate ion-flux mediated regulation of membrane potential specifically to prevent and cause regression of oncogene-induced tumors. Injection of mutant-KRAS mRNA induces tumor-like structures with many documented similarities to tumors, in Xenopus tadpoles. We show that expression and activation of either ChR2D156A, a blue-light activated cation channel, or Arch, a green-light activated proton pump, both of which hyperpolarize cells, significantly lowers the incidence of KRAS tumor formation. Excitingly, we also demonstrate that activation of co-expressed light-activated ion translocators after tumor formation significantly increases the frequency with which the tumors regress in a process called normalization. These data demonstrate an optogenetic approach to dissect the biophysics of cancer. Moreover, they provide proof-of-principle for a novel class of interventions, directed at regulating cell state by targeting physiological regulators that can over-ride the presence of mutations.
Collapse
|
11
|
Filby A. Sample preparation for flow cytometry benefits from some lateral thinking. Cytometry A 2016; 89:1054-1056. [DOI: 10.1002/cyto.a.23021] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2016] [Accepted: 10/27/2016] [Indexed: 12/12/2022]
Affiliation(s)
- Andrew Filby
- Flow Cytometry Core Facility, Faculty of Medical Sciences; Newcastle University; Newcastle-upon-Tyne NE1 7RU United Kingdom
| |
Collapse
|
12
|
Adams DS, Uzel SGM, Akagi J, Wlodkowic D, Andreeva V, Yelick PC, Devitt-Lee A, Pare JF, Levin M. Bioelectric signalling via potassium channels: a mechanism for craniofacial dysmorphogenesis in KCNJ2-associated Andersen-Tawil Syndrome. J Physiol 2016; 594:3245-70. [PMID: 26864374 PMCID: PMC4908029 DOI: 10.1113/jp271930] [Citation(s) in RCA: 99] [Impact Index Per Article: 12.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2015] [Accepted: 02/01/2016] [Indexed: 12/21/2022] Open
Abstract
KEY POINTS Xenopus laevis craniofacial development is a good system for the study of Andersen-Tawil Syndrome (ATS)-associated craniofacial anomalies (CFAs) because (1) Kcnj2 is expressed in the nascent face; (2) molecular-genetic and biophysical techniques are available for the study of ion-dependent signalling during craniofacial morphogenesis; (3) as in humans, expression of variant Kcnj2 forms in embryos causes a muscle phenotype; and (4) variant forms of Kcnj2 found in human patients, when injected into frog embryos, cause CFAs in the same cell lineages. Forced expression of WT or variant Kcnj2 changes the normal pattern of Vmem (resting potential) regionalization found in the ectoderm of neurulating embryos, and changes the normal pattern of expression of ten different genetic regulators of craniofacial development, including markers of cranial neural crest and of placodes. Expression of other potassium channels and two different light-activated channels, all of which have an effect on Vmem , causes CFAs like those induced by injection of Kcnj2 variants. In contrast, expression of Slc9A (NHE3), an electroneutral ion channel, and of GlyR, an inactive Cl(-) channel, do not cause CFAs, demonstrating that correct craniofacial development depends on a pattern of bioelectric states, not on ion- or channel-specific signalling. Using optogenetics to control both the location and the timing of ion flux in developing embryos, we show that affecting Vmem of the ectoderm and no other cell layers is sufficient to cause CFAs, but only during early neurula stages. Changes in Vmem induced late in neurulation do not affect craniofacial development. We interpret these data as strong evidence, consistent with our hypothesis, that ATS-associated CFAs are caused by the effect of variant Kcnj2 on the Vmem of ectodermal cells of the developing face. We predict that the critical time is early during neurulation, and the critical cells are the ectodermal cranial neural crest and placode lineages. This points to the potential utility of extant, ion flux-modifying drugs as treatments to prevent CFAs associated with channelopathies such as ATS. ABSTRACT Variants in potassium channel KCNJ2 cause Andersen-Tawil Syndrome (ATS); the induced craniofacial anomalies (CFAs) are entirely unexplained. We show that KCNJ2 is expressed in Xenopus and mouse during the earliest stages of craniofacial development. Misexpression in Xenopus of KCNJ2 carrying ATS-associated mutations causes CFAs in the same structures affected in humans, changes the normal pattern of membrane voltage potential regionalization in the developing face and disrupts expression of important craniofacial patterning genes, revealing the endogenous control of craniofacial patterning by bioelectric cell states. By altering cells' resting potentials using other ion translocators, we show that a change in ectodermal voltage, not tied to a specific protein or ion, is sufficient to cause CFAs. By adapting optogenetics for use in non-neural cells in embryos, we show that developmentally patterned K(+) flux is required for correct regionalization of the resting potentials and for establishment of endogenous early gene expression domains in the anterior ectoderm, and that variants in KCNJ2 disrupt this regionalization, leading to the CFAs seen in ATS patients.
Collapse
Affiliation(s)
- Dany Spencer Adams
- Department of Biology and Tufts Centre for Regenerative and Developmental Biology, Tufts University, 200 Boston Avenue, Medford, MA, 02155, USA
| | - Sebastien G M Uzel
- Department of Mechanical Engineering, Massachusetts Institute of Technology, 77 Massachusetts Avenue, Cambridge, MA, 02139, USA
| | - Jin Akagi
- School of Applied Sciences, RMIT University, Melbourne, Australia
| | - Donald Wlodkowic
- School of Applied Sciences, RMIT University, Melbourne, Australia
| | - Viktoria Andreeva
- Department of Orthodontics, Division of Craniofacial and Molecular Genetics, Tufts University School of Dental Medicine, Boston, MA 02111, USA
| | - Pamela Crotty Yelick
- Department of Orthodontics, Division of Craniofacial and Molecular Genetics, Tufts University School of Dental Medicine, Boston, MA 02111, USA
| | - Adrian Devitt-Lee
- Department of Biology and Tufts Centre for Regenerative and Developmental Biology, Tufts University, 200 Boston Avenue, Medford, MA, 02155, USA
| | - Jean-Francois Pare
- Department of Biology and Tufts Centre for Regenerative and Developmental Biology, Tufts University, 200 Boston Avenue, Medford, MA, 02155, USA
| | - Michael Levin
- Department of Biology and Tufts Centre for Regenerative and Developmental Biology, Tufts University, 200 Boston Avenue, Medford, MA, 02155, USA
| |
Collapse
|
13
|
Yang F, Gao C, Wang P, Zhang GJ, Chen Z. Fish-on-a-chip: microfluidics for zebrafish research. LAB ON A CHIP 2016; 16:1106-25. [PMID: 26923141 DOI: 10.1039/c6lc00044d] [Citation(s) in RCA: 37] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/02/2023]
Abstract
High-efficiency zebrafish (embryo) handling platforms are crucially needed to facilitate the deciphering of the increasingly expanding vertebrate-organism model values. However, the manipulation platforms for zebrafish are scarce and rely mainly on the conventional "static" microtiter plates or glass slides with rigid gel, which limits the dynamic, three-dimensional (3D), tissue/organ-oriented information acquisition from the intact larva with normal developmental dynamics. In addition, these routine platforms are not amenable to high-throughput handling of such swimming multicellular biological entities at the single-organism level and incapable of precisely controlling the growth microenvironment by delivering stimuli in a well-defined spatiotemporal fashion. Recently, microfluidics has been developed to address these technical challenges via tailor-engineered microscale structures or structured arrays, which integrate with or interface to functional components (e.g. imaging systems), allowing quantitative readouts of small objects (zebrafish larvae and embryos) under normal physiological conditions. Here, we critically review the recent progress on zebrafish manipulation, imaging and phenotype readouts of external stimuli using these microfluidic tools and discuss the challenges that confront these promising "fish-on-a-chip" technologies. We also provide an outlook on future potential trends in this field by combining with bionanoprobes and biosensors.
Collapse
Affiliation(s)
- Fan Yang
- School of Laboratory Medicine, Hubei University of Chinese Medicine, 1 Huangjia Lake West Road, Wuhan 430065, China.
| | - Chuan Gao
- School of Laboratory Medicine, Hubei University of Chinese Medicine, 1 Huangjia Lake West Road, Wuhan 430065, China.
| | - Ping Wang
- School of Basic Medicine, Hubei University of Chinese Medicine, 1 Huangjia Lake West Road, Wuhan 430065, China
| | - Guo-Jun Zhang
- School of Laboratory Medicine, Hubei University of Chinese Medicine, 1 Huangjia Lake West Road, Wuhan 430065, China.
| | - Zuanguang Chen
- School of Pharmaceutical Sciences, Sun Yat-sen University, Guangzhou, 510006, China
| |
Collapse
|
14
|
Zhu F, Wigh A, Friedrich T, Devaux A, Bony S, Nugegoda D, Kaslin J, Wlodkowic D. Automated Lab-on-a-Chip Technology for Fish Embryo Toxicity Tests Performed under Continuous Microperfusion (μFET). ENVIRONMENTAL SCIENCE & TECHNOLOGY 2015; 49:14570-8. [PMID: 26506399 DOI: 10.1021/acs.est.5b03838] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/20/2023]
Abstract
The fish embryo toxicity (FET) biotest has gained popularity as one of the alternative approaches to acute fish toxicity tests in chemical hazard and risk assessment. Despite the importance and common acceptance of FET, it is still performed in multiwell plates and requires laborious and time-consuming manual manipulation of specimens and solutions. This work describes the design and validation of a microfluidic Lab-on-a-Chip technology for automation of the zebrafish embryo toxicity test common in aquatic ecotoxicology. The innovative device supports rapid loading and immobilization of large numbers of zebrafish embryos suspended in a continuous microfluidic perfusion as a means of toxicant delivery. Furthermore, we also present development of a customized mechatronic automation interface that includes a high-resolution USB microscope, LED cold light illumination, and miniaturized 3D printed pumping manifolds that were integrated to enable time-resolved in situ analysis of developing fish embryos. To investigate the applicability of the microfluidic FET (μFET) in toxicity testing, copper sulfate, phenol, ethanol, caffeine, nicotine, and dimethyl sulfoxide were tested as model chemical stressors. Results obtained on a chip-based system were compared with static protocols performed in microtiter plates. This work provides evidence that FET analysis performed under microperfusion opens a brand new alternative for inexpensive automation in aquatic ecotoxicology.
Collapse
Affiliation(s)
| | - Adriana Wigh
- Université de Lyon, UMR LEHNA 5023, USC INRA, ENTPE, rue Maurice Audin, Vaulx-en-Velin F-69518, France
| | - Timo Friedrich
- ARMI, Monash University , Wellington Road, Clayton, VIC 3800, Australia
| | - Alain Devaux
- Université de Lyon, UMR LEHNA 5023, USC INRA, ENTPE, rue Maurice Audin, Vaulx-en-Velin F-69518, France
| | - Sylvie Bony
- Université de Lyon, UMR LEHNA 5023, USC INRA, ENTPE, rue Maurice Audin, Vaulx-en-Velin F-69518, France
| | - Dayanthi Nugegoda
- Ecotoxicology Research Group, School of Applied Sciences, RMIT University , Bowen Street, Melbourne, VIC 3001, Australia
| | - Jan Kaslin
- ARMI, Monash University , Wellington Road, Clayton, VIC 3800, Australia
| | - Donald Wlodkowic
- Centre for Additive Manufacturing, RMIT University , 58 Cardigan Street, Melbourne, VIC 3053, Australia
| |
Collapse
|
15
|
Melzer S, Ankri R, Fixler D, Tarnok A. Nanoparticle uptake by macrophages in vulnerable plaques for atherosclerosis diagnosis. JOURNAL OF BIOPHOTONICS 2015; 8:871-83. [PMID: 26110589 DOI: 10.1002/jbio.201500114] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/20/2015] [Revised: 05/11/2015] [Accepted: 06/03/2015] [Indexed: 05/11/2023]
Abstract
The composition of atherosclerotic (AS) plaques is crucial concerning rupture, thrombosis and clinical events. Two plaque types are distinguished: stable and vulnerable plaques. Vulnerable plaques are rich in inflammatory cells, mostly only M1 macrophages, and are highly susceptible to rupture. These plaques represent a high risk particularly with the standard invasive diagnosis by coronary angiography. So far there are no non-invasive low-risk clinical approaches available to detect and distinguish AS plaque types in vivo. The perspective review introduces a whole work-flow for a novel approach for non-invasive detection and classification of AS plaques using the diffusion reflection method with gold nanoparticle loaded macrophages in combination with flow and image cytometric analysis for quality assurance. Classical biophotonic methods for AS diagnosis are summarized. Phenotyping of monocytes and macrophages are discussed for specific subset labelling by nanomaterials, as well as existing studies and first experimental proofs of concept for the novel approach are shown. In vitro and in vivo detection of NP loaded macrophages (MΦ). Different ways of MΦ labelling include (1) in vitro labelling in suspension (whole blood or buffy coat) or (2) labelling of short-term MΦ cultures with re-injection of MΦ-NP into the animal to detect migration of the cells in the plaques and (3) in vivo injection of NP into the organism.
Collapse
Affiliation(s)
- Susanne Melzer
- LIFE Leipziger Forschungszentrum für Zivilisationserkrankungen, Universität Leipzig, Leipzig, Germany
- Department of Pediatric Cardiology, Cardiac Center GmbH, University of Leipzig, Leipzig, Germany
| | - Rinat Ankri
- Faculty of Engineering and Institute of Nanotechnology and Advanced Materials, Bar-Ilan University, Ramat-Gan, 5290002, Israel
| | - Dror Fixler
- Faculty of Engineering and Institute of Nanotechnology and Advanced Materials, Bar-Ilan University, Ramat-Gan, 5290002, Israel
| | - Attila Tarnok
- Department of Pediatric Cardiology, Cardiac Center GmbH, University of Leipzig, Leipzig, Germany.
- Translational Centre for Regenerative Medicine (TRM) Leipzig, Leipzig, Germany.
| |
Collapse
|
16
|
Zhu F, Hall CJ, Crosier PS, Wlodkowic D. Interfacing Lab-on-a-Chip Embryo Technology with High-Definition Imaging Cytometry. Zebrafish 2015; 12:315-8. [DOI: 10.1089/zeb.2015.1105] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/15/2023] Open
Affiliation(s)
- Feng Zhu
- The BioMEMS Research Group, School of Applied Sciences, RMIT University, Victoria, Australia
| | - Christopher J. Hall
- Department of Molecular Medicine and Pathology, University of Auckland, Auckland, New Zealand
| | - Philip S. Crosier
- Department of Molecular Medicine and Pathology, University of Auckland, Auckland, New Zealand
| | - Donald Wlodkowic
- The BioMEMS Research Group, School of Applied Sciences, RMIT University, Victoria, Australia
- Centre for Additive Manufacturing, RMIT University, Melbourne, Australia
- Centre for Environmental Sustainability and Remediation, RMIT University, Melbourne, Australia
| |
Collapse
|
17
|
Zhu F, Skommer J, Macdonald NP, Friedrich T, Kaslin J, Wlodkowic D. Three-dimensional printed millifluidic devices for zebrafish embryo tests. BIOMICROFLUIDICS 2015; 9:046502. [PMID: 26339325 PMCID: PMC4514717 DOI: 10.1063/1.4927379] [Citation(s) in RCA: 37] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/10/2015] [Accepted: 06/09/2015] [Indexed: 05/07/2023]
Abstract
Implementations of Lab-on-a-Chip technologies for in-situ analysis of small model organisms and embryos (both invertebrate and vertebrate) are attracting an increasing interest. A significant hurdle to widespread applications of microfluidic and millifluidic devices for in-situ analysis of small model organisms is the access to expensive clean room facilities and complex microfabrication technologies. Furthermore, these resources require significant investments and engineering know-how. For example, poly(dimethylsiloxane) soft lithography is still largely unattainable to the gross majority of biomedical laboratories willing to pursue development of chip-based platforms. They often turn instead to readily available but inferior classical solutions. We refer to this phenomenon as workshop-to-bench gap of bioengineering science. To tackle the above issues, we examined the capabilities of commercially available Multi-Jet Modelling (MJM) and Stereolithography (SLA) systems for low volume fabrication of optical-grade millifluidic devices designed for culture and biotests performed on millimetre-sized specimens such as zebrafish embryos. The selected 3D printing technologies spanned a range from affordable personal desktop systems to high-end professional printers. The main motivation of our work was to pave the way for off-the-shelf and user-friendly 3D printing methods in order to rapidly and inexpensively build optical-grade millifluidic devices for customized studies on small model organisms. Compared with other rapid prototyping technologies such as soft lithography and infrared laser micromachining in poly(methyl methacrylate), we demonstrate that selected SLA technologies can achieve user-friendly and rapid production of prototypes, superior feature reproduction quality, and comparable levels of optical transparency. A caution need to be, however, exercised as majority of tested SLA and MJM resins were found toxic and caused significant developmental abnormalities in zebrafish embryos. Taken together, our data demonstrate that SLA technologies can be used for rapid and accurate production of devices for biomedical research. However, polymer biotoxicity needs to be carefully evaluated.
Collapse
Affiliation(s)
- Feng Zhu
- The BioMEMS Research Group, School of Applied Sciences, RMIT University , Melbourne, Victoria 3083, Australia
| | - Joanna Skommer
- The BioMEMS Research Group, School of Applied Sciences, RMIT University , Melbourne, Victoria 3083, Australia
| | - Niall P Macdonald
- School of Engineering, University of Glasgow , Glasgow G12 8QQ, United Kingdom
| | - Timo Friedrich
- Australian Regenerative Medicine Institute, Monash University , Clayton, Victoria 3800, Australia
| | - Jan Kaslin
- Australian Regenerative Medicine Institute, Monash University , Clayton, Victoria 3800, Australia
| | | |
Collapse
|
18
|
Zhu F, Baker D, Skommer J, Sewell M, Wlodkowic D. Real-time 2D visualization of metabolic activities in zebrafish embryos using a microfluidic technology. Cytometry A 2015; 87:446-50. [PMID: 25808962 DOI: 10.1002/cyto.a.22662] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2014] [Revised: 02/05/2015] [Accepted: 03/03/2015] [Indexed: 11/06/2022]
Abstract
Non-invasive and real-time visualization of metabolic activities in living small model organisms such as embryos and larvae of zebrafish has not yet been attempted largely due to profound analytical limitations of existing technologies. Historically, our capacity to examine oxygen gradients surrounding eggs and embryos has been severely limited, so much so that to date, most of the articles characterizing in situ oxygen gradients have described predominantly mathematical simulations. These drawbacks can, however, be experimentally addressed by an emerging field of microfluidic Lab-on-a-Chip (LOC) technologies combined with sophisticated optoelectronic sensors. In this work, we outline a proof-of-concept approach utilizing microfluidic living embryo array system to enable in situ Fluorescence Ratiometric Imaging (FRIM) on developing zebrafish embryos. The FRIM is an innovative method for kinetic quantification of the temporal patterns of aqueous oxygen gradients at a very fine scale based on signals coming from an optical sensor referred to as a sensor foil. We envisage that future integration of microfluidic chip-based technologies with FRIM represents a noteworthy direction to miniaturize and revolutionize research on metabolism and physiology in vivo.
Collapse
Affiliation(s)
- Feng Zhu
- School of Applied Sciences, RMIT University, Melbourne, Victoria, Australia
| | | | | | | | | |
Collapse
|
19
|
Skommer J, Wlodkowic D. Successes and future outlook for microfluidics-based cardiovascular drug discovery. Expert Opin Drug Discov 2015; 10:231-44. [PMID: 25672221 DOI: 10.1517/17460441.2015.1001736] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023]
Abstract
INTRODUCTION The greatest advantage of using microfluidics as a platform for the assessment of cardiovascular drug action is its ability to finely regulate fluid flow conditions, including flow rate, shear stress and pulsatile flow. At the same time, microfluidics provide means for modifying the vessel geometry (bifurcations, stenoses, complex networks), the type of surface of the vessel walls, and for patterning cells in 3D tissue-like architecture, including generation of lumen walls lined with cells and heart-on-a-chip structures for mimicking ventricular cardiomyocyte physiology. In addition, owing to the small volume of required specimens, microfluidics is ideally suited to clinical situations whereby monitoring of drug dosing or efficacy needs to be coupled with minimal phlebotomy-related drug loss. AREAS COVERED In this review, the authors highlight potential applications for the currently existing and emerging technologies and offer several suggestions on how to close the development cycle of microfluidic devices for cardiovascular drug discovery. EXPERT OPINION The ultimate goal in microfluidics research for drug discovery is to develop 'human-on-a-chip' systems, whereby several organ cultures, including the vasculature and the heart, can mimic complex interactions between the organs and body systems. This would provide in vivo-like pharmacokinetics and pharmacodynamics for drug ADMET assessment. At present, however, the great variety of available designs does not go hand in hand with their use by the pharmaceutical community.
Collapse
Affiliation(s)
- Joanna Skommer
- RMIT University, School of Applied Sciences , Melbourne, VIC , Australia
| | | |
Collapse
|
20
|
Akagi J, Zhu F, Skommer J, Hall CJ, Crosier PS, Cialkowski M, Wlodkowic D. Microfluidic device for a rapid immobilization of zebrafish larvae in environmental scanning electron microscopy. Cytometry A 2014; 87:190-4. [PMID: 25483307 DOI: 10.1002/cyto.a.22603] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2014] [Revised: 11/07/2014] [Accepted: 11/20/2014] [Indexed: 11/10/2022]
Abstract
Small vertebrate model organisms have recently gained popularity as attractive experimental models that enhance our understanding of human tissue and organ development. Despite a large body of evidence using optical spectroscopy for the characterization of small model organism on chip-based devices, no attempts have been so far made to interface microfabricated technologies with environmental scanning electron microscopy (ESEM). Conventional scanning electron microscopy requires high vacuum environments and biological samples must be, therefore, submitted to many preparative procedures to dehydrate, fix, and subsequently stain the sample with gold-palladium deposition. This process is inherently low-throughput and can introduce many analytical artifacts. This work describes a proof-of-concept microfluidic chip-based system for immobilizing zebrafish larvae for ESEM imaging that is performed in a gaseous atmosphere, under low vacuum mode and without any need for sample staining protocols. The microfabricated technology provides a user-friendly and simple interface to perform ESEM imaging on zebrafish larvae. Presented lab-on-a-chip device was fabricated using a high-speed infrared laser micromachining in a biocompatible poly(methyl methacrylate) thermoplastic. It consisted of a reservoir with multiple semispherical microwells designed to hold the yolk of dechorionated zebrafish larvae. Immobilization of the larvae was achieved by a gentle suction generated during blotting of the medium. Trapping region allowed for multiple specimens to be conveniently positioned on the chip-based device within few minutes for ESEM imaging.
Collapse
Affiliation(s)
- Jin Akagi
- School of Applied Sciences, RMIT, University Melbourne, Victoria, Australia
| | | | | | | | | | | | | |
Collapse
|