Coetzee LM, Glencross DK. Performance verification of the new fully automated Aquios flow cytometer PanLeucogate (PLG) platform for CD4-T-lymphocyte enumeration in South Africa. PLoS One 2017; 12:e0187456. [PMID: 29099874 PMCID: PMC5669480 DOI: 10.1371/journal.pone.0187456] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2017] [Accepted: 10/22/2017] [Indexed: 11/18/2022] Open
Abstract
BACKGROUND The National Health Laboratory Service (NHLS) offers wide-scale CD4 testing through a network of laboratories in South Africa. A new "load and go" cytometer (Aquios CL, Beckman Coulter), developed with a PLG protocol, was validated against the predicate PLG method on the Beckman Coulter FC500 MPL/CellMek platform. METHODS Remnant routine EDTA blood CD4 reference results were compared to results from two Aquios/PLG instruments (n = 205) and a further n = 1885 samples tested to assess daily testing capacity. Reproducibility was assessed using ImmunotrolTM and patient samples with low, medium, high CD4 counts. Data was analyzed using GraphPad software for general statistics and Bland-Altman (BA) analyses. The percentage similarity (%Sim) was used to measure the level of agreement (accuracy) of the new platform versus the predicate and variance (%SimCV) reported to indicate precision of difference to predicate. RESULTS 205 samples were tested with a CD4 count range of 2-1228 cells/μl (median 365cells/μl). BA analysis revealed an overall -40.5±44.0cells/μl bias (LOA of 126.8 to 45.8cells/μl) and %Sim showing good agreement and tight precision to predicate results (94.83±5.39% with %SimCV = 5.69%). Workflow analysis (n = 1885) showed similar outcomes 94.9±8.9% (CV of 9.4%) and 120 samples/day capacity. Excellent intra-instrument reproducibility was noted (%Sim 98.7±2.8% and %SimCV of 2.8%). 5-day reproducibility using internal quality control material (Immunotrol™) showed tight precision (reported %CV of 4.69 and 7.62 for Normal and Low material respectively) and instrument stability. CONCLUSION The Aquios/PLG CD4 testing platform showed clinically acceptable result reporting to existing predicate results, with good system stability and reproducibility with a slight negative but precise bias. This system can replace the faded XL cytometers in low- to medium volume CD4 testing laboratories, using the standardized testing protocol, with better staff utilization especially where technical skills are lacking. Central monitoring of on-board quality assessment data facilitates proactive maintenance and networked instrument performance monitoring.
Collapse
Affiliation(s)
- Lindi-Marie Coetzee
- Department of Molecular Medicine and Haematology, Faculty of Health Sciences, University of the Witwatersrand, Johannesburg, South Africa
- National Health Laboratory Service (NHLS), CD4 Unit, Charlotte Maxeke Hospital, Johannesburg, South Africa
- * E-mail:
| | - Deborah K. Glencross
- Department of Molecular Medicine and Haematology, Faculty of Health Sciences, University of the Witwatersrand, Johannesburg, South Africa
- National Health Laboratory Service (NHLS), CD4 Unit, Charlotte Maxeke Hospital, Johannesburg, South Africa
| |
Collapse
|
2
|
Peeling RW, Sollis KA, Glover S, Crowe SM, Landay AL, Cheng B, Barnett D, Denny TN, Spira TJ, Stevens WS, Crowley S, Essajee S, Vitoria M, Ford N. CD4 enumeration technologies: a systematic review of test performance for determining eligibility for antiretroviral therapy. PLoS One 2015; 10:e0115019. [PMID: 25790185 PMCID: PMC4366094 DOI: 10.1371/journal.pone.0115019] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2014] [Accepted: 11/17/2014] [Indexed: 12/04/2022] Open
Abstract
Background Measurement of CD4+ T-lymphocytes (CD4) is a crucial parameter in the management of HIV patients, particularly in determining eligibility to initiate antiretroviral treatment (ART). A number of technologies exist for CD4 enumeration, with considerable variation in cost, complexity, and operational requirements. We conducted a systematic review of the performance of technologies for CD4 enumeration. Methods and Findings Studies were identified by searching electronic databases MEDLINE and EMBASE using a pre-defined search strategy. Data on test accuracy and precision included bias and limits of agreement with a reference standard, and misclassification probabilities around CD4 thresholds of 200 and 350 cells/μl over a clinically relevant range. The secondary outcome measure was test imprecision, expressed as % coefficient of variation. Thirty-two studies evaluating 15 CD4 technologies were included, of which less than half presented data on bias and misclassification compared to the same reference technology. At CD4 counts <350 cells/μl, bias ranged from -35.2 to +13.1 cells/μl while at counts >350 cells/μl, bias ranged from -70.7 to +47 cells/μl, compared to the BD FACSCount as a reference technology. Misclassification around the threshold of 350 cells/μl ranged from 1-29% for upward classification, resulting in under-treatment, and 7-68% for downward classification resulting in overtreatment. Less than half of these studies reported within laboratory precision or reproducibility of the CD4 values obtained. Conclusions A wide range of bias and percent misclassification around treatment thresholds were reported on the CD4 enumeration technologies included in this review, with few studies reporting assay precision. The lack of standardised methodology on test evaluation, including the use of different reference standards, is a barrier to assessing relative assay performance and could hinder the introduction of new point-of-care assays in countries where they are most needed.
Collapse
Affiliation(s)
- Rosanna W. Peeling
- London School of Hygiene and Tropical Medicine, London, WC1E 7HT, England
- * E-mail:
| | - Kimberly A. Sollis
- London School of Hygiene and Tropical Medicine, London, WC1E 7HT, England
| | - Sarah Glover
- London School of Hygiene and Tropical Medicine, London, WC1E 7HT, England
| | - Suzanne M. Crowe
- Centre for Biomedical Research, Burnet Institute, Melbourne, 3004, Victoria, Australia
| | - Alan L. Landay
- Department of Immunology/Microbiology, Rush University Medical Center, Chicago, IL, 60612, United States of America
| | - Ben Cheng
- Pangaea Global AIDS Foundation, Oakland, CA, 94607, United States of America
| | - David Barnett
- UK NEQAS for Leucocyte Immunophenotyping, Sheffield, S10 2QD, England
| | - Thomas N. Denny
- Duke Human Vaccine Institute and Center for HIV/AIDS, Immunology and Virology Quality Assessment Center, Durham, NC, 27710, United States of America
| | - Thomas J. Spira
- Division of AIDS, STD, &TB Laboratory Research, National Center for Infectious Diseases, Centers for Disease Control and Prevention, Atlanta, GA, 30333, United States of America
| | | | - Siobhan Crowley
- Director Health Programs, ELMA Philanthropies, New York, NY, United States of America
| | - Shaffiq Essajee
- Clinton Health Access Initiative, Boston, MA, 02127, United States of America
| | | | - Nathan Ford
- World Health Organization, Geneva, Switzerland
| |
Collapse
|
3
|
Field evaluation in Chad of community usage of CD4 T lymphocyte counting by alternative single-platform flow cytometry. BMC Health Serv Res 2013; 13:373. [PMID: 24083615 PMCID: PMC3849920 DOI: 10.1186/1472-6963-13-373] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2013] [Accepted: 09/27/2013] [Indexed: 11/30/2022] Open
Abstract
Background Field and community evaluation of the routine usage of CD4 T counting platforms is essential in resource-poor countries for efficient and cost-effective monitoring of HIV-infected adults and children attending health care centers. Methods We herein addressed the principal issues raised by the implementation of the single-platform, volumetric Auto40 flow cytometer (Apogee Flow Systems Ltd, Hemel Hempstead, UK) in 8 community HIV monitoring laboratories of different levels throughout Chad. This is a country with particularly difficult conditions, both in terms of climate and vast geographical territory, making the decentralization of the therapeutic management of HIV-infected patients challenging. Results The routine usage of the Auto40 flow cytometers for a period of 5 years (2008–2013) confirms the reliability and robustness of the analyzer for community-based CD4 T cell enumeration in terms of both absolute numbers and percentages to enable accurate monitoring of HIV-infected adults and children. However, our observations suggest that the Auto40 mini flow cytometer is not suitable for all laboratories as it is oversized and ultimately very expensive. Conclusion The Chad experience with the Auto40 flow cytometer suggests that its usage in resource-limited settings should be mainly reserved to reference (level 1) or district (level 2) laboratories, rather than to laboratories of health care centres (level 3).
Collapse
|
4
|
Koyalta D, Jenabian MA, Nadjiouroum N, Djouater B, Djemadji-Oudjeil N, Ndjoyi-Mbiguino A, Bélec L. Single-platform, volumetric, CD45-assisted pan-leucogating flow cytometry for CD4 T lymphocytes monitoring of HIV infection according to the WHO recommendations for resource-constrained settings. BMC Res Notes 2013; 6:169. [PMID: 23631664 PMCID: PMC3653683 DOI: 10.1186/1756-0500-6-169] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2012] [Accepted: 04/25/2013] [Indexed: 11/25/2022] Open
Abstract
Background Validation of new affordable CD4 T cell measurement technologies is crucial specifically in resource-poor countries for antiretroviral treatment eligibility and immunologic CD4 monitoring of HIV-infected patients. Methods The absolute and percentage CD4 T cell counts of 258 HIV-1-infected blood samples (182 adults and 76 children), living in N’Djamena, Chad, were performed by single-platform, volumetric, CD45-assisted pan-leucogating Auto40 flow cytometer (Apogee Flow Systems Ltd, Hemel Hempstead, UK) comparing to the FACSCalibur flow cytometer as a reference method. Results Absolute and percentage CD4 T cell counts obtained by Auto40 and FACSCalibur of 258 HIV-1-infected blood samples were highly correlated (r = 0.99 and r = 0.96, respectively). The mean absolute bias and percent bias between Apogee Auto40 and FACSCalibur absolute CD4 T cell counts, were −9.4 cells/μl with limits of agreement from −15 to 93 cells/μl, and +2.0% with limits of agreement from −0.9 to 4.9%, respectively. The mean of absolute bias and percent bias between Apogee Auto40 and FACSCalibur of CD4 percentage results were +0.4% (95% CI: -0.02 – 0.86) with limits of agreement from −2.4 to 0.3%, and +3.0% with limits of agreement from −6.6 to 0.6%, respectively. The Auto40 counting allowed to identify the majority of adults with CD4 T cells below 200 cells/μl (sensitivity: 89%; specificity: 99%) or below 350 cells/μl (sensitivity: 94%; specificity:98%); and of children below 750 cells/μl (sensitivity: 99%; specificity: 96%) or below 25% CD4+ (sensitivity: 94%; specificity: 98%). Conclusion The Auto40 analyzer is an alternative flow cytometer for CD4 T lymphocyte enumeration to be used in routine for immunological monitoring according to the current WHO recommendations in HIV-infected adults as well as children living in resource-constrained settings like Chad.
Collapse
|
5
|
Validation of a single-platform, volumetric, CD45-assisted PanLeucogating Auto40 flow cytometer to determine the absolute number and percentages of CD4 T cells in resource-constrained settings using Cameroonian patients' samples. CLINICAL AND VACCINE IMMUNOLOGY : CVI 2012; 19:609-15. [PMID: 22336291 DOI: 10.1128/cvi.00023-12] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
The study evaluated the single-platform, volumetric, CD45-assisted PanLeucogating Auto40 flow cytometer (Apogee Flow Systems Ltd., Hemel Hempstead, United Kingdom) for CD4 T cell numeration, compared to the reference FACSCalibur flow cytometer. Results of absolute counts and percentages of CD4 T cells by Auto40 and FACSCalibur of 234 tripotassium EDTA (K3-EDTA)-blood samples from 146 adults and 88 children (aged from 18 months to 5 years), living in Yaoundé, Cameroon, were highly correlated (r(2) = 0.97 and r(2) = 0.98, respectively). The mean absolute bias and relative bias between Apogee Auto40 and FACSCalibur absolute CD4 T cell counts were +9.6 cells/μl, with limits of agreement from -251 to 270 cells/μl, and +4.1%, with limits of agreement from -16.1 to 24.4%, respectively. The mean absolute bias and relative bias between Apogee Auto40 and FACSCalibur CD4 T cell results expressed as percentages were +0.05% CD4 (95% confidence interval [CI], -0.03 to 0.41), with limits of agreement from -6.0 to 5.9% CD4, and +1.0%, with limits of agreement from -32.3 to 34.4%, respectively. The Auto40 counting allowed identification of the majority of adults with CD4 T cell counts below 200 cells/μl (sensitivity, 87%; specificity, 98%) or below 350 cells/μl (sensitivity, 92%; specificity, 98%) and of children with CD4 T cell counts below 750 cells/μl (sensitivity, 82%; specificity, 98%) or below 25% CD4(+) (sensitivity, 96%; specificity, 99%). The Auto40 analyzer is a reliable alternative flow cytometer for CD4 T lymphocyte enumeration to be used in routine immunological monitoring according to the WHO recommendations for HIV-infected adults as well as children living in resource-constrained settings.
Collapse
|
6
|
Nantakomol D, Dondorp AM, Krudsood S, Udomsangpetch R, Pattanapanyasat K, Combes V, Grau GE, White NJ, Viriyavejakul P, Day NPJ, Chotivanich K. Circulating red cell-derived microparticles in human malaria. J Infect Dis 2011; 203:700-6. [PMID: 21282195 DOI: 10.1093/infdis/jiq104] [Citation(s) in RCA: 124] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/15/2023] Open
Abstract
In patients with falciparum malaria, plasma concentrations of cell-derived microparticles correlate with disease severity. Using flow cytometry, we quantified red blood cell-derived microparticles (RMPs) in patients with malaria and identified the source and the factors associated with production. RMP concentrations were increased in patients with Plasmodium falciparum (n = 29; median, 457 RMPs/μL [range, 13-4,342 RMPs/μL]), Plasmodium vivax (n = 5; median, 409 RMPs/μL [range, 281-503/μL]), and Plasmodium malariae (n = 2; median, 163 RMPs/μL [range, 127-200 RMPs/μL]) compared with those in healthy subjects (n = 11; median, 8 RMPs/μL [range, 3-166 RMPs/μL]; P = .01). RMP concentrations were highest in patients with severe falciparum malaria (P = .01). Parasitized red cells produced >10 times more RMPs than did unparasitized cells, but the overall majority of RMPs still derived from uninfected red blood cells (URBCs). In cultures, RMP production increased as the parasites matured. Hemin and parasite products induced RMP production in URBCs, which was inhibited by N-acetylcysteine, suggesting heme-mediated oxidative stress as a pathway for the generation of RMPs.
Collapse
Affiliation(s)
- Duangdao Nantakomol
- Department of Clinical Microscopy, Faculty of Allied Health Science, Chulalongkorn University, Bangkok, Thailand
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
7
|
Nanzigu S, Waako P, Petzold M, Kiwanuka G, Dungu H, Makumbi F, Gustafsson LL, Eriksen J. CD4-T-Lymphocyte Reference Ranges in Uganda and Its Influencing Factors. Lab Med 2011. [DOI: 10.1309/lmft0vce1ugo9ygd] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022] Open
|
8
|
Fischer JC, Quenzel EM, Moog R, Wenzel F, Riethmacher R, Tutschek B, Giers G. Reducing costs in flow-cytometric counting of residual white blood cells in blood products: utilization of a single-platform bead-free flow-rate calibration method. Transfusion 2011; 51:1431-8. [PMID: 21214578 DOI: 10.1111/j.1537-2995.2010.02998.x] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
BACKGROUND Commercial flow-cytometric methods for counting residual white blood cells (rWBCs) in leukoreduced blood products use calibration beads for estimation of the measured sample volume. A bead-free flow-rate calibration method is developed and validated. STUDY DESIGN AND METHODS The analyzed volume was calculated by acquisition time (ACQ). Twenty-nine spiking series of red blood cell (RBC) or platelet (PLT) products were prepared containing levels ranging from 0.08 × 10(6) up to 2048 × 10(6) WBCs/L. Nearly WBC-free triple-leukofiltered RBCs or PLT concentrates (PCs) served as background. Propidium iodide (PI) was used to identify rWBCs. Five RBC series were compared against a commercially available kit (LeukoSure, Beckman Coulter). Routine capabilities were tested on 41 RBC and 92 PC samples of two independent transfusion services. RESULTS The lower detection limit in RBC was 0.08 × 10(6) rWBCs/L for ACQ and 0.16 for LeukoSure. Criteria for linearity, accuracy, and precision were fulfilled within the range of 0.5 × 10(6) to 512 × 10(6) WBCs/L. For PCs, all these criteria were fulfilled between 0.5 × 10(6) and 32 × 10(6) rWBCs/L (lower detection limit of 0.25) for PI. ACQ and LeukoSure agreed sufficiently (81%) when tested on routine RBCs or PCs. CONCLUSION A residual WBC count of fewer than 0.5 × 10(6) WBCs/L can be accurately counted using the ACQ approach at a total reagent cost of less than 0.5€ per sample.
Collapse
Affiliation(s)
- Johannes C Fischer
- Institute for Transplantation Diagnostics and Cell Therapy, University of Duesseldorf, Duesseldorf, Germany.
| | | | | | | | | | | | | |
Collapse
|
9
|
Nantakomol D, Nuchnoi P, Noulsri E, Lerdwana S, Krisin S, Chanprasert S, Pattanapanyasat K. Enumeration of the absolute CD4 T-lymphocyte count by cell-bead assay. CYTOMETRY PART B-CLINICAL CYTOMETRY 2010; 78:260-6. [PMID: 20309993 DOI: 10.1002/cyto.b.20518] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
BACKGROUND We have previously developed an alternative approach for undertaking absolute cell counting based upon flow-rate calibration using cell bead (FCB), in which cell bead (CB) can be used as a flow-rate calibration material for generating the absolute microparticle counts. Here, we extended our work of counting CD4+ T-lymphocytes in HIV-infected blood samples with the FCB method. METHODS CD4+ T-lymphocyte counts in EDTA blood samples from 30 healthy subjects and 80 HIV-1-infected patients were determined using TriTEST reagent. The absolute CD4+ T-lymphocytes were measured by FCB, and the results were compared with the absolute counting by commercial latex bead (CLB) or with flow rate-based calibration method (FR). Statistical correlation and agreement were analyzed using linear regression and Bland-Altman analysis. RESULTS There was no significant difference in the absolute number of CD4+ T-lymphocyte counts enumerated by FCB when compared with those two reference methods (CLB and FR). The absolute CD4+ T-lymphocyte counts obtained from FCB method was highly correlated with those obtained from CLB [r(2)= 0.99, y = 1.04x - 12.37, P < 0.001, and mean bias 11.96 cell/microl, limit of agreement (LOA) -57.82 - 81.74 cell/microl], FR method (r(2) = 0.98; y = 0.97x - 3.13, P < 0.001, and mean bias -24.15 cell/microl, LOA -114.44 - 66.13 cell/microl). CONCLUSIONS The use of FCB is comparable with the use of CLB and FR. This approach showed the effective in reducing cost for generating the absolute CD4+ T-lymphocyte counts. Such an approach should facilitate and ensure the success of the ongoing antiretroviral therapy program in resource-limited countries.
Collapse
Affiliation(s)
- Duangdao Nantakomol
- Department of Clinical Microscopy, Faculty of Allied Health Sciences, Chulalongkorn University, Bangkok, Thailand.
| | | | | | | | | | | | | |
Collapse
|
10
|
Nantakomol D, Chanprasert S, Soogarun S, Imwong M, Ohashi J, Nuchnoi P. Affordable Technology for Enumeration of the Absolute CD4 T-Lymphocyte Count by Cell Bead Assay. Lab Med 2010. [DOI: 10.1309/lmvkkifto4ynagpa] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022] Open
|
11
|
From research tool to routine test: CD38 monitoring in HIV patients. CYTOMETRY PART B-CLINICAL CYTOMETRY 2009; 76:375-84. [DOI: 10.1002/cyto.b.20478] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
|
12
|
Nantakomol D, Imwong M, Soontarawirat I, Kotjanya D, Khakhai C, Ohashi J, Nuchnoi P. The absolute counting of red cell-derived microparticles with red cell bead by flow rate based assay. CYTOMETRY PART B-CLINICAL CYTOMETRY 2009; 76:191-8. [DOI: 10.1002/cyto.b.20465] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
13
|
Stevens W, Gelman R, Glencross DK, Scott LE, Crowe SM, Spira T. Evaluating new CD4 enumeration technologies for resource-constrained countries. Nat Rev Microbiol 2008; 6:S29-38. [PMID: 22745957 DOI: 10.1038/nrmicro2000] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
14
|
Walker C, Barnett D. Flow rate calibration for absolute cell counting rationale and design. ACTA ACUST UNITED AC 2008; Chapter 6:Unit6.24. [PMID: 18770842 DOI: 10.1002/0471142956.cy0624s36] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
There is a need for absolute leukocyte enumeration in the clinical setting, and accurate, reliable (and affordable) technology to determine absolute leukocyte counts has been developed. Such technology includes single platform and dual platform approaches. Derivations of these counts commonly incorporate the addition of a known number of latex microsphere beads to a blood sample, although it has been suggested that the addition of beads to a sample may only be required to act as an internal quality control procedure for assessing the pipetting error. This unit provides the technical details for undertaking flow rate calibration that obviates the need to add reference beads to each sample. It is envisaged that this report will provide the basis for subsequent clinical evaluations of this novel approach.
Collapse
Affiliation(s)
- Clare Walker
- Royal Hallamshire Hospital, Sheffield, United Kingdom
| | | |
Collapse
|
15
|
Pattanapanyasat K, Chimma P, Sratongno P, Lerdwana S. CD4+T-lymphocyte enumeration with a flow-rate based method in three flow cytometers with different years in service. CYTOMETRY PART B-CLINICAL CYTOMETRY 2008; 74:310-8. [DOI: 10.1002/cyto.b.20425] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
16
|
Meditz AL, Schlichtemeier R, Folkvord JM, Givens M, Lesh KC, Ray M, McCarter MD, Connick E. SDF-1alpha is a potent inducer of HIV-1-Specific CD8+ T-cell chemotaxis, but migration of CD8+ T cells is impaired at high viral loads. AIDS Res Hum Retroviruses 2008; 24:977-85. [PMID: 18671480 DOI: 10.1089/aid.2007.0259] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
Multiple impairments in HIV-1-specific cytotoxic T cells (CTL) have been reported, but derangements in HIV-1-specific CD8+ T-cell chemotaxis have not been described previously. We assessed migration to SDF-1alpha (stromal cell-derived factor 1-alpha) and CX3CL1 in vitro and expression of cognate receptors, CXCR4 and CX3CR1, by flow cytometry in peripheral blood and lymph node CD8+ T cells from HIV-1-seropositive and -seronegative individuals. Compared with seronegative individuals, percentages of CXCR4+CD8+ T cells were reduced (median, 26% versus 74%, p < 0.001) and percentages of CX3CR1+CD8+ T cells were increased (median, 33% versus 15%, p = 0.03) in seropositive individuals. Robust migration of peripheral blood mononuclear cell (PBMC) CD8+ T cells to SDF-1alpha (1 alphag/ml) was observed in both HIV-1-seropositive (median chemotactic index [CI] 4.9) and -seronegative (median CI 2.8) subjects (p = 0.46). CI to SDF-1alpha was not significantly related to percentage of CXCR4+CD8+ T cells or density of CXCR4, but correlated inversely with plasma HIV-1 RNA concentration (r = -0.82, p = 0.03). Little chemotaxis was observed in response to CX3CL1 and it was unrelated to CX3CR1 expression. Lymph node CD8+ T-cell chemotaxis to SDF-1alpha and CX3CL1 in four subjects demonstrated the same patterns observed in PBMC. HIV-1-specific tetramer-staining CD8+ T cells exhibited chemotaxis of similar magnitude as PBMC CD8+ T cells in a subset of subjects. These data suggest that SDF-1alpha is a potent chemoattractant for HIV-1-specific CTL, but that impairments in migration of HIV-1-specific CTL may exist at high viral loads. Improved understanding of the determinants of CTL localization may provide insight into novel therapies to enhance delivery of CTL to sites of HIV-1 replication.
Collapse
Affiliation(s)
- Amie L. Meditz
- Division of Infectious Diseases, Department of Medicine, University of Colorado Health Sciences Center, Denver, Colorado 80262
| | - Rick Schlichtemeier
- Division of Infectious Diseases, Department of Medicine, University of Colorado Health Sciences Center, Denver, Colorado 80262
| | - Joy M. Folkvord
- Division of Infectious Diseases, Department of Medicine, University of Colorado Health Sciences Center, Denver, Colorado 80262
| | - Monique Givens
- Division of Infectious Diseases, Department of Medicine, University of Colorado Health Sciences Center, Denver, Colorado 80262
- Present address: Research and Development, Gambro BCT, Lakewood, Colorado 80215
| | - Kevin C. Lesh
- Division of Infectious Diseases, Department of Medicine, University of Colorado Health Sciences Center, Denver, Colorado 80262
- Present address: Lynn Institute of the Rockies, Colorado Springs, Colorado 80909
| | - M.G. Ray
- Division of Infectious Diseases, Department of Medicine, University of Colorado Health Sciences Center, Denver, Colorado 80262
| | - Martin D. McCarter
- Department of Surgery, University of Colorado Health Sciences Center, Denver, Colorado 80262
| | - Elizabeth Connick
- Division of Infectious Diseases, Department of Medicine, University of Colorado Health Sciences Center, Denver, Colorado 80262
| |
Collapse
|
17
|
Denny TN, Gelman R, Bergeron M, Landay A, Lam L, Louzao R, Mandy FF, Schmitz J, Spira T, Wilkening C, Glencross DK. A North American multilaboratory study of CD4 counts using flow cytometric panLeukogating (PLG): a NIAID-DAIDS Immunology Quality Assessment Program Study. CYTOMETRY PART B-CLINICAL CYTOMETRY 2008; 74 Suppl 1:S52-64. [PMID: 18351622 DOI: 10.1002/cyto.b.20417] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
BACKGROUND The global HIV/AIDS pandemic and guidelines for initiating anti-retroviral therapy (ART) and opportunistic infection prophylaxis demand affordable, reliable, and accurate CD4 testing. A simple innovative approach applicable to existing technology that has been successfully applied in resource-challenged settings, PanLeukogated CD4 (PLG), could offer solutions for cost saving and improved precision. METHODS Day-old whole blood from 99 HIV+ donors was simultaneously studied in five North-American laboratories to compare the performance of their predicate methods with the dual-platform PLG method. The predicate technology included varying 4-color CD45/CD3/CD4/CD8 protocols on different flow cytometers. Each laboratory also assayed eight replicate specimens of day-old blood from 10 to 14 local donors. Bias and precision of predicate and PLG methods was studied between- and within-participating laboratories. RESULTS Significantly (P < 0.0001) improved between-laboratory precision/coefficient of variation (CV%) was noted using the PLG method (overall median 9.3% vs. predicate median CV 13.1%). Within-laboratory precision was also significantly (P < 0.0001) better overall using PLG (median 4.6% vs. predicate median CV 6.2%) and in 3 of the 5 laboratories. PLG counts tended to be 11% smaller than predicate methods (P < 0.0001) for shipped (median of predicate-PLG = 31) and local specimens (median of predicate-PLG = 23), both overall and in 4 of 5 laboratories (median decreases of 4, 16, 20, and 21% in shipped specimens); the other laboratory had a median increase of 5%. CONCLUSION Laboratories using predicate CD4 methods similar to those in this study could improve their between-laboratory and their within-laboratory precision, and reduce costs, by switching to the PLG method after adequate training, if a change (usually, a decrease) in CD4 counts is acceptable to their health systems.
Collapse
Affiliation(s)
- Thomas N Denny
- Human Vaccine Institute, Duke University Medical Center, Durham, USA.
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
18
|
Sippy-Chatrani N, Marshall S, Branch S, Carmichael-Simmons K, Landis RC, Abayomi A. Performance of the Panleucogating protocol for CD4+T cell enumeration in an HIV dedicated laboratory facility in Barbados. CYTOMETRY PART B-CLINICAL CYTOMETRY 2008; 74 Suppl 1:S65-8. [DOI: 10.1002/cyto.b.20406] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
19
|
Glencross DK, Janossy G, Coetzee LM, Lawrie D, Aggett HM, Scott LE, Sanne I, McIntyre JA, Stevens W. Large-scale affordable Panleucogated CD4+testing with proactive internal and external quality assessment: In support of the South African national comprehensive care, treatment and management programme for HIV and AIDS. CYTOMETRY PART B-CLINICAL CYTOMETRY 2008; 74 Suppl 1:S40-51. [DOI: 10.1002/cyto.b.20384] [Citation(s) in RCA: 50] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
20
|
Bold A, Wurth R, Keller T, Trahorsch U, Voigt P, Schubert S, Sack U. Low-cost enumeration of CD4+ T cells using a density-based negative selection method (RosetteSep™) for the monitoring of HIV-infected individuals in non-OECD countries. Cytometry A 2007; 73:28-35. [DOI: 10.1002/cyto.a.20494] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
|
21
|
Walker CL, Whitby L, Granger V, Storie I, Reilly JT, Barnett D. Flow rate calibration. III. The use of stabilized biostandards to calibrate the flow rate and calculate absolute CD4+ T-cell counts. CYTOMETRY PART B-CLINICAL CYTOMETRY 2006; 70:154-62. [PMID: 16572418 DOI: 10.1002/cyto.b.20103] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
BACKGROUND We have previously reported a flow rate calibration method for the determination of absolute CD4(+) T-lymphocyte counts that removes the need for the addition of latex beads to each sample. However, a limitation with this approach is that a calibration factor (CF) needs to be applied to adjust for differences in viscosity between latex bead suspensions and biological specimens. We have also demonstrated the value of using stabilized whole blood samples in external quality assessment (EQA) studies; such samples have a stable absolute lymphocyte count for over 1 year, at 4 degrees C. It was successfully demonstrated that this material can be used as a flow rate biocalibration (FRB) material for use as a flow cytometric control to provide a sample with a known CD4(+) T-lymphocyte count. Such material has advantages over latex bead technology as it can act as a full process control as well as having the same matrix and viscosity characteristics as the test material, thus removing the need for a CF. METHODS In this study, we have analyzed 268 consecutive normal, abnormal, and HIV(+) samples using FRB, incorporating the PanLeucoGating approach and compared this to the MultiSet method, defined as the predicate. RESULTS Percentage similarity statistics revealed the following: 0-3,000 CD4(+) cells/mul mean percentage difference (MPD; bias) 1.2%, 95% CI of 5.6-8%; 0-200 CD4(+) cells/microl MPD of 1.25%, 95% CI of 11.63-14.13%; 201-500 CD4(+) cells/microl MPD of 1%, 95% CI of 4.6-6.6%. DISCUSSION This study demonstrates that stabilized whole blood can be used for FRB. It has the advantage of being a full process control, in addition to costing less than latex beads with highly comparable results. As bench top flow cytometers are extremely stable, this is a low cost and robust alternative to bead based methods for generating absolute CD4 counts.
Collapse
Affiliation(s)
- Clare L Walker
- UK NEQAS for Leucocyte Immunophenotyping, Department of Haematology, Royal Hallamshire Hospital, Sheffield
| | | | | | | | | | | |
Collapse
|
22
|
Barbesti S, Soldini L, Carcelain G, Guignet A, Colizzi V, Mantelli B, Corvaglia A, Tran-Minh T, Dorigatti F, Autran B, Lazzarin A, Beretta A. A simplified flow cytometry method of CD4 and CD8 cell counting based on thermoresistant reagents: implications for large scale monitoring of HIV-infected patients in resource-limited settings. CYTOMETRY PART B-CLINICAL CYTOMETRY 2006; 68:43-51. [PMID: 16184613 DOI: 10.1002/cyto.b.20068] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
OBJECTIVE To validate a simplified flow cytometry assay for CD4 and CD8 T cell counting based on monoclonal antibodies which are made resistant to high temperatures (simplified thermoresistant assay (STRA)). METHOD The STRA employs FITC-conjugated anti-CD4 and anti-CD8 monoclonal antibodies, predispensed into test tubes and chemically treated to be resistant to high temperatures. Five correlation studies were performed in three different laboratories on a total of 560 blood samples from HIV-1 infected patients. Each study correlated the STRA with either double or single platform assays currently available. Accelerated stability tests on the FITC-conjugated monoclonal antibodies were performed to assess the resistance of the STRA to high temperatures. RESULTS Comparison of STRA with both single platform and double platform assays gave correlation coefficients ranging 0.957-0.987 for CD4+ T cells and 0.946-0.968 for CD8+ T cells. In all correlation studies there was a perfect data overlapping in the low-pathological interval of CD4+ T cells (0-400 cells/ml). The FITC-conjugated CD4 and CD8 monoclonal antibodies maintained intact binding activity and fluorescence brightness after storage for 4 weeks at 45 degrees C and can be stored for up to 8 years in regular conditions (+4 degrees C). CONCLUSIONS The STRA correlates well with both single-platform and double-platform flow-cytometry assays currently used to assess CD4+ T cells. The test procedure is simple, rapid, and easy to perform. The reagents can be stored under unfavorable environmental conditions for long period of time. These features should facilitate access to flow cytometry testing in resource-poor settings.
Collapse
|
23
|
Storie I, Sawle A, Goodfellow K, Whitby L, Granger V, Reilly JT, Barnett D. Flow rate calibration I: a novel approach for performing absolute cell counts. CYTOMETRY. PART B, CLINICAL CYTOMETRY 2003; 55:1-7. [PMID: 12949953 DOI: 10.1002/cyto.b.10051] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
BACKGROUND Reports suggest that flow rate (FR) is constant on bench top flow cytometers. Therefore, if FR is constant, the volume acquired in a fixed time period will also be constant, enabling absolute leucocyte counting using flow rate calibration (FRC). METHODS FR stability was ascertained on a standard FACSCalibur by counting TruCount beads suspended in phosphate buffered saline over 120 s. Studies using two lysing solutions (FACS lysing solution and PharM Lyse) and corresponding sample lysates established a lysing solution calibration factor (CF). Absolute CD4(+) T-lymphocyte counts on 10 peripheral blood samples determined using FRC were compared with the predicate method TruCount/MultiTEST, incorporating MultiSET software. Linearity studies were also performed at three different flow rates. RESULTS A high degree of linearity over a wide range of counts (50 to >1,600 CD4(+) T lymphocytes/microl) at all three pressures was observed. Importantly, there was no significant difference from the predicate method when appropriate lysing solution CF was used. CONCLUSIONS Using a simple calibration procedure and incorporation of an appropriate lysing solution CF, we show that FRC can easily be performed. The technical details that underpin this novel approach for absolute leucocyte enumeration are provided.
Collapse
Affiliation(s)
- Ian Storie
- UK NEQAS for Leucocyte Immunophenotyping, Royal Hallamshire Hospital, Sheffield, United Kingdom
| | | | | | | | | | | | | |
Collapse
|