1
|
Ogata T, Kurita Y, Sato T, Yagi S, Hasegawa S, Hosono K, Kobayashi N, Endo I, Kubota K, Nakajima A. Thin Delivery Stents Can Obviate the Need for Additional Fistula Dilatation of Large Diameter in Endoscopic Ultrasound-Guided Hepaticogastrostomy. J Clin Med 2024; 13:6328. [PMID: 39518467 PMCID: PMC11546826 DOI: 10.3390/jcm13216328] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2024] [Revised: 10/10/2024] [Accepted: 10/18/2024] [Indexed: 11/16/2024] Open
Abstract
Background/Objectives: Endoscopic ultrasound-guided hepaticogastrostomy (EUS-HGS) often requires fistula dilation owing to the placement of a large diameter of the delivery stent. The recently developed delivery devices, which are as thin as 5.9/6.0 Fr, may save the need for fistula dilation. Therefore, we investigated whether large fistula dilation would be required or not in the case of this newly developed thin-diameter delivery stents. Methods: We conducted a retrospective study involving 33 patients implemented with a self-expandable metal stent (SEMS) during EUS-HGS. The patients were categorized based on the delivery device diameter into thin (n = 13; delivery device diameter: 5.9/6.0 Fr) and thick (n = 20; delivery device diameter: 8.5 Fr) groups. We compared the initial rate of success, technical success, and clinical success between the thin and thick groups. The initial rate of success was defined as successful stent placement without a balloon or large diameter mechanical dilation. Results: The rate of the initial stenting success was significantly higher in the thin group (100% [13/13]) compared with that in the thick group (65.0% [13/20]) (p = 0.027). In the thick group, seven cases with technical difficulty in terms of stent placement could be successfully completed with additional fistula dilation with a 9 Fr bougie dilator or 4 mm balloon dilator; this resulted in a technical success of 100% in both groups ultimately. The rate of clinical success was 100% and 95.0% in the thin and thick groups, respectively (p = 1.00). Conclusions: Thin delivery stents may facilitate stent placement without the need for a balloon fistula or large-diameter mechanical dilation.
Collapse
Affiliation(s)
- Tomoki Ogata
- Department of Gastroenterology and Hepatology, Yokohama City University, Yokohama 236-0004, Japan; (T.O.); (T.S.); (S.Y.); (S.H.); (K.H.); (K.K.); (A.N.)
| | - Yusuke Kurita
- Department of Gastroenterology and Hepatology, Yokohama City University, Yokohama 236-0004, Japan; (T.O.); (T.S.); (S.Y.); (S.H.); (K.H.); (K.K.); (A.N.)
| | - Takamitsu Sato
- Department of Gastroenterology and Hepatology, Yokohama City University, Yokohama 236-0004, Japan; (T.O.); (T.S.); (S.Y.); (S.H.); (K.H.); (K.K.); (A.N.)
| | - Shin Yagi
- Department of Gastroenterology and Hepatology, Yokohama City University, Yokohama 236-0004, Japan; (T.O.); (T.S.); (S.Y.); (S.H.); (K.H.); (K.K.); (A.N.)
| | - Sho Hasegawa
- Department of Gastroenterology and Hepatology, Yokohama City University, Yokohama 236-0004, Japan; (T.O.); (T.S.); (S.Y.); (S.H.); (K.H.); (K.K.); (A.N.)
| | - Kunihiro Hosono
- Department of Gastroenterology and Hepatology, Yokohama City University, Yokohama 236-0004, Japan; (T.O.); (T.S.); (S.Y.); (S.H.); (K.H.); (K.K.); (A.N.)
| | | | - Itaru Endo
- Department of Gastroenterological Surgery, Yokohama City University Hospital, Yokohama 236-0004, Japan;
| | - Kensuke Kubota
- Department of Gastroenterology and Hepatology, Yokohama City University, Yokohama 236-0004, Japan; (T.O.); (T.S.); (S.Y.); (S.H.); (K.H.); (K.K.); (A.N.)
| | - Atsushi Nakajima
- Department of Gastroenterology and Hepatology, Yokohama City University, Yokohama 236-0004, Japan; (T.O.); (T.S.); (S.Y.); (S.H.); (K.H.); (K.K.); (A.N.)
| |
Collapse
|
2
|
Okuno N, Hara K, Haba S, Kuwahara T, Fukui T, Urata M, Yamamoto Y, Kondo T. The New Potential for Using Franseen Needles in Interventional EUS. Intern Med 2024; 63:2723-2727. [PMID: 38403760 PMCID: PMC11557192 DOI: 10.2169/internalmedicine.3207-23] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/13/2023] [Accepted: 01/04/2024] [Indexed: 02/27/2024] Open
Abstract
Objective Adverse events such as bile leakage and bleeding are among the issues that need to be resolved in EUS-guided choledochoduodenostomy (EUS-CDS). To overcome this problem, we developed a new EUS-CDS technique using a 19-G Franseen needle without tract dilation. This study aimed to evaluate the safety and efficacy of the new EUS-CDS technique. Methods This single-center retrospective study included 20 consecutive patients who underwent EUS-CDS for primary drainage using a 19-G Franseen needle between March 2020 and May 2023. The primary endpoint was the technical success rate of EUS-CDS without tract dilation. Results The technical success rate of EUS-CDS was 20/20 (100%). None of the patients required any additional tract dilation, such as by using a balloon or electric cautery. The median procedure time was 7.8 [range, 3.2-19.4] min. No early adverse events were observed. Conclusion The 19-G Franseen needle appeared to have a sufficient dilatory effect during puncturing. This EUS-CDS technique appears to be safe and effective and has the advantages of no adverse events and it is also a simplified procedure, which suggests its potential for widespread use in primary drainage.
Collapse
Affiliation(s)
- Nozomi Okuno
- Department of Gastroenterology, Aichi Cancer Center Hospital, Japan
| | - Kazuo Hara
- Department of Gastroenterology, Aichi Cancer Center Hospital, Japan
| | - Shin Haba
- Department of Gastroenterology, Aichi Cancer Center Hospital, Japan
| | | | - Toshitaka Fukui
- Department of Gastroenterology, Aichi Cancer Center Hospital, Japan
| | - Minako Urata
- Department of Gastroenterology, Aichi Cancer Center Hospital, Japan
| | | | - Takashi Kondo
- Department of Gastroenterology, Aichi Cancer Center Hospital, Japan
| |
Collapse
|
3
|
Koga T, Ishida Y, Hashigo S, Shimokawa Y, Harima H, Okamoto K, Ohno A, Miyagahara T, Fujita T, Fukuchi S, Takahashi K, Taguchi H, Araki N, Ohtsuka Y, Uekitani T, Tsuneyoshi K, Akiyama T, Ishigaki N, Maruo T, Saito H, Ihara R, Yamasuji A, Oe S, Yoshinari M, Sagami R, Fujimori N, Fukuda Y, Ozawa E, Jikuya K, Shinohara H, Sen-Yo M, Ueki T, Tsuchiya N, Kitaguchi T, Matsumoto K, Fukuyama M, Hirai F. Feasibility and safety of EUS-guided biliary drainage in inexperienced centers: a multicenter study in southwest Japan. Gastrointest Endosc 2024:S0016-5107(24)03495-3. [PMID: 39278283 DOI: 10.1016/j.gie.2024.09.014] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/13/2024] [Revised: 07/30/2024] [Accepted: 09/07/2024] [Indexed: 09/18/2024]
Abstract
BACKGROUND AND AIMS EUS-guided biliary drainage (EUS-BD) has shown promising procedural outcomes in high-volume centers. Although inferior procedural outcomes were reported in inexperienced centers during the early days of EUS-BD, the current outcomes are unknown. This study aimed to clarify the feasibility and safety of EUS-BD in centers that recently introduced EUS-BD. METHODS This multicenter retrospective study was conducted at 22 centers that introduced EUS-BD between 2017 and 2022. A maximum of 20 initial EUS-BD cases at each center were evaluated. The clinical outcomes and experience of 84 endoscopists who performed these procedures were examined. Primary outcomes were the rate of technical success and adverse events (AEs), whereas secondary outcomes were risk factors associated with technical failure and procedure-related AEs. RESULTS Two hundred fifty-five patients were enrolled. The technical success rate was 91.4% (233/255). Among 22 technical failure cases, guidewire manipulation failure was the most common cause (n = 12) followed by tract dilation failure (n = 5). The AE rate was 10.2% (26/255). Multivariate analysis identified a puncture target diameter of <5 mm (odds ratio, 3.719; 95% CI, 1.415-9.776; P = .008) and moderate ascites extending to the liver surface (odds ratio, 3.25; 95% CI, 1.195-8.653; P = .021) as independent risk factors for technical failure and procedure-related AEs, respectively. Endoscopists' procedural experience was not a risk factor for technical failure or procedure-related AEs. CONCLUSIONS The feasibility and safety of EUS-BD were maintained during the induction phase at inexperienced centers. These data will be helpful to better understand the current status of EUS-BD. (Clinical trial registration number: UMIN 000053615.).
Collapse
Affiliation(s)
- Takehiko Koga
- Department of Gastroenterology and Medicine, Faculty of Medicine, Fukuoka University, Fukuoka, Japan
| | - Yusuke Ishida
- Department of Gastroenterology and Medicine, Faculty of Medicine, Fukuoka University, Fukuoka, Japan
| | - Shunpei Hashigo
- Department of Gastroenterology, Kumamoto University Hospital, Kumamoto, Japan
| | - Yuzo Shimokawa
- Department of Gastroenterology, Kitakyushu Municipal Medical Center, Fukuoka, Japan
| | - Hirofumi Harima
- Department of Gastroenterology, Saiseikai Shimonoseki General Hospital, Yamaguchi, Japan
| | - Kazuhisa Okamoto
- Department of Gastroenterology, Faculty of Medicine, Oita University, Oita, Japan
| | - Akihisa Ohno
- Department of Medicine and Bioregulatory Science, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
| | - Tsukasa Miyagahara
- Department of Gastroenterology, National Hospital Organization Beppu Medical Center, Oita, Japan
| | - Toshihiro Fujita
- Department of Gastroenterology, Kagoshima Kouseiren Hospital, Kagoshima, Japan
| | - Satoshi Fukuchi
- Department of Gastroenterology, Oita City Medical Association Almeida Memorial Hospital, Oita, Japan
| | - Kosuke Takahashi
- Department of Gastroenterology and Hepatology, Nagasaki University Graduate School of Biomedical Sciences, Nagasaki, Japan
| | - Hiroki Taguchi
- Department of Gastroenterology, Imamura General Hospital, Kagoshima, Japan
| | - Norimasa Araki
- Department of Gastroenterology, Fujimoto General Hospital, Miyazaki, Japan
| | - Yuichiro Ohtsuka
- Department of Gastroenterology, Oita Medical Center, Oita, Japan
| | - Toshiyuki Uekitani
- Department of Gastroenterology, Tokuyama Central Hospital, Yamaguchi, Japan
| | - Kengo Tsuneyoshi
- Department of Gastroenterology Izumi General Medical Center, Kagoshima, Japan
| | - Takumi Akiyama
- Division of Metabolism and Endocrinology, Faculty of Medicine, Saga University, Saga, Japan
| | - Noriko Ishigaki
- Department of Gastroenterology, Saiseikai Yamaguchi General Hospital, Yamaguchi, Japan
| | - Toru Maruo
- Department of Gastroenterology, Fukuoka University Chikushi Hospital, Fukuoka, Japan
| | - Hirokazu Saito
- Department of Gastroenterology, Kumamoto City Hospital, Kumamoto, Japan
| | - Ryo Ihara
- Department of Pancreatology, Kyushu Central Hospital, Fukuoka, Japan
| | - Akihiro Yamasuji
- Department of Gastroenterology, Ikeda Hospital, Kagoshima, Japan
| | - Shinji Oe
- Third Department of Internal Medicine, School of Medicine, University of Occupational and Environmental Health, Fukuoka, Japan
| | - Motohiro Yoshinari
- Department of Gastroenterology, Kumamoto University Hospital, Kumamoto, Japan
| | - Ryota Sagami
- Department of Gastroenterology, Faculty of Medicine, Oita University, Oita, Japan
| | - Nao Fujimori
- Department of Medicine and Bioregulatory Science, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
| | - Yoshio Fukuda
- Department of Gastroenterology, Kagoshima Kouseiren Hospital, Kagoshima, Japan
| | - Eisuke Ozawa
- Department of Gastroenterology and Hepatology, Nagasaki University Graduate School of Biomedical Sciences, Nagasaki, Japan
| | - Kenichi Jikuya
- Department of Gastroenterology, Imamura General Hospital, Kagoshima, Japan
| | - Hiroki Shinohara
- Department of Gastroenterology, Fujimoto General Hospital, Miyazaki, Japan
| | - Manabu Sen-Yo
- Department of Gastroenterology, Tokuyama Central Hospital, Yamaguchi, Japan
| | - Toshiharu Ueki
- Department of Gastroenterology, Fukuoka University Chikushi Hospital, Fukuoka, Japan
| | - Naoaki Tsuchiya
- Department of Gastroenterology and Medicine, Faculty of Medicine, Fukuoka University, Fukuoka, Japan
| | - Takanori Kitaguchi
- Department of Gastroenterology and Medicine, Faculty of Medicine, Fukuoka University, Fukuoka, Japan
| | - Keisuke Matsumoto
- Department of Gastroenterology and Medicine, Faculty of Medicine, Fukuoka University, Fukuoka, Japan
| | - Makoto Fukuyama
- Department of Gastroenterology and Medicine, Faculty of Medicine, Fukuoka University, Fukuoka, Japan
| | - Fumihito Hirai
- Department of Gastroenterology and Medicine, Faculty of Medicine, Fukuoka University, Fukuoka, Japan
| |
Collapse
|
4
|
Itonaga M, Ashida R, Hatamaru K, Yamashita Y, Kawaji Y, Tamura T, Emori T, Shishimoto T, Koutani H, Tamura T, Nakahata A, Yamazaki H, Kitano M. Endoscopic ultrasound-guided hepaticogastrostomy vs. antegrade metal stent placement keeping an access route in patients with malignant biliary obstruction. Int J Clin Oncol 2024:10.1007/s10147-024-02584-2. [PMID: 38972023 DOI: 10.1007/s10147-024-02584-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2024] [Accepted: 07/04/2024] [Indexed: 07/08/2024]
Abstract
BACKGROUND Few studies have compared endoscopic ultrasound (EUS)-guided hepaticogastrostomy (HGS) with EUS-guided antegrade metal stent placement (AGMS). The purpose of this study was to compare times to recurrent biliary obstruction (TRBO) in patients who underwent HGS using metal stents (MS) and those who underwent AGMS keeping access routes with plastic stents (AGMS-AR). METHODS This study retrospectively evaluated consecutive patients who underwent HGS or AGMS between September 2016 and December 2022. TRBO, overall survival (OS), and adverse event (AE) rates were compared in the two groups. The risk factors for RBO were determined using a multivariable Cox proportional hazards model. RESULTS This study included 32 patients in the HGS group and 30 in the AGMS-AR group. Technical success rate was significantly higher in the HGS than in the AGMS-AR group (100 vs. 80%; P = 0.009). The technical success rate without tract dilation was significantly higher in the AGMS-AR than in the HGS group (83 vs. 38%; P < 0.001). RBO rates were significantly higher in the HGS than in the AGMS-AR group (53 vs. 17%; P = 0.024), whereas AE rates did not differ significantly. TRBO differed significantly in the HGS and AGMS-AR groups (159 days vs. not reached, P = 0.011), whereas OS did not differ significantly. Multivariable analysis revealed that HGS was an independent risk factor for RBO (hazard ratio, 6.48, P = 0.014). CONCLUSION TRBO was significantly longer in patients who underwent AGMS with PS than HGS. AGMS with PS may be effective after the failure of ERCP in patients with malignant biliary obstruction.
Collapse
Affiliation(s)
- Masahiro Itonaga
- Second Department of Internal Medicine, Wakayama Medical University, 811-1 Kimiidera, Wakayama, 641-0012, Japan
| | - Reiko Ashida
- Second Department of Internal Medicine, Wakayama Medical University, 811-1 Kimiidera, Wakayama, 641-0012, Japan
| | - Keiichi Hatamaru
- Second Department of Internal Medicine, Wakayama Medical University, 811-1 Kimiidera, Wakayama, 641-0012, Japan
| | - Yasunobu Yamashita
- Second Department of Internal Medicine, Wakayama Medical University, 811-1 Kimiidera, Wakayama, 641-0012, Japan
| | - Yuki Kawaji
- Second Department of Internal Medicine, Wakayama Medical University, 811-1 Kimiidera, Wakayama, 641-0012, Japan
| | - Takashi Tamura
- Second Department of Internal Medicine, Wakayama Medical University, 811-1 Kimiidera, Wakayama, 641-0012, Japan
| | - Tomoya Emori
- Second Department of Internal Medicine, Wakayama Medical University, 811-1 Kimiidera, Wakayama, 641-0012, Japan
| | - Takahiro Shishimoto
- Second Department of Internal Medicine, Wakayama Medical University, 811-1 Kimiidera, Wakayama, 641-0012, Japan
| | - Hiromu Koutani
- Second Department of Internal Medicine, Wakayama Medical University, 811-1 Kimiidera, Wakayama, 641-0012, Japan
| | - Takaaki Tamura
- Second Department of Internal Medicine, Wakayama Medical University, 811-1 Kimiidera, Wakayama, 641-0012, Japan
| | - Akiya Nakahata
- Second Department of Internal Medicine, Wakayama Medical University, 811-1 Kimiidera, Wakayama, 641-0012, Japan
| | - Hirofumi Yamazaki
- Second Department of Internal Medicine, Wakayama Medical University, 811-1 Kimiidera, Wakayama, 641-0012, Japan
| | - Masayuki Kitano
- Second Department of Internal Medicine, Wakayama Medical University, 811-1 Kimiidera, Wakayama, 641-0012, Japan.
| |
Collapse
|
5
|
Itonaga M, Ashida R, Emori T, Hatamaru K, Yamashita Y, Kawaji Y, Tamura T, Tuda I, Tamura T, Koutani H, Yamazaki H, Shimokawa T, Kitano M. Safety of skipping the tract dilation step for EUS-guided biliary drainage in patients with unresectable malignant biliary obstruction (with video). Surg Endosc 2024; 38:2288-2296. [PMID: 38488871 DOI: 10.1007/s00464-024-10731-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2023] [Accepted: 01/28/2024] [Indexed: 03/17/2024]
Abstract
BACKGROUND Thin delivery system stents can be inserted directly without the need for a tract dilation step and are expected to reduce bile leakage during endoscopic ultrasound-guided biliary drainage (EUS-BD). The present study retrospectively compared the safety and efficacy of EUS-BD using a thin metal stent (< 7.5 Fr) with those of EUS-BD using a conventional stent (≥ 7.5 Fr). METHODS The present study enrolled 112 patients who underwent EUS-BD using metal stents for unresectable malignant biliary obstruction between April 2016 and July 2022. The primary endpoint was the rate of adverse events (AEs). The secondary endpoints were clinical success rate, procedure time, procedure success rate in the absence of the tract dilation step, recurrent biliary obstruction rate, time to biliary obstruction, and overall survival. Risk factors associated with early AEs were also evaluated. RESULTS The rate of early AEs was significantly lower (12% vs. 35%, P = 0.013) and the procedure success without the tract dilation step was significantly higher (82% vs. 33%, P < 0.001) in the thin than in the conventional delivery system stent group. None of the other secondary endpoints differed significantly between the two groups. Multivariate analysis showed that employing the tract dilation step during EUS-BD was a significant independent risk factor for early AEs (skipping vs. employing; HR, 9.66; 95% CI, 1.13-83.0, P = 0.028). CONCLUSION Employing the tract dilation step during EUS-BD was a significant risk factor for early AEs. Metal stents with a delivery diameter < 7.5 Fr can be inserted directly without the tract dilation step, resulting in lower early AE rates.
Collapse
Affiliation(s)
- Masahiro Itonaga
- Second Department of Internal Medicine, Wakayama Medical University, 811-1 Kimiidera, Wakayama City, Wakayama, 641-0012, Japan
| | - Reiko Ashida
- Second Department of Internal Medicine, Wakayama Medical University, 811-1 Kimiidera, Wakayama City, Wakayama, 641-0012, Japan
| | - Tomoya Emori
- Second Department of Internal Medicine, Wakayama Medical University, 811-1 Kimiidera, Wakayama City, Wakayama, 641-0012, Japan
| | - Keiichi Hatamaru
- Second Department of Internal Medicine, Wakayama Medical University, 811-1 Kimiidera, Wakayama City, Wakayama, 641-0012, Japan
| | - Yasunobu Yamashita
- Second Department of Internal Medicine, Wakayama Medical University, 811-1 Kimiidera, Wakayama City, Wakayama, 641-0012, Japan
| | - Yuki Kawaji
- Second Department of Internal Medicine, Wakayama Medical University, 811-1 Kimiidera, Wakayama City, Wakayama, 641-0012, Japan
| | - Takashi Tamura
- Second Department of Internal Medicine, Wakayama Medical University, 811-1 Kimiidera, Wakayama City, Wakayama, 641-0012, Japan
| | - Ikuhisa Tuda
- Second Department of Internal Medicine, Wakayama Medical University, 811-1 Kimiidera, Wakayama City, Wakayama, 641-0012, Japan
| | - Takaaki Tamura
- Second Department of Internal Medicine, Wakayama Medical University, 811-1 Kimiidera, Wakayama City, Wakayama, 641-0012, Japan
| | - Hiromu Koutani
- Second Department of Internal Medicine, Wakayama Medical University, 811-1 Kimiidera, Wakayama City, Wakayama, 641-0012, Japan
| | - Hirofumi Yamazaki
- Second Department of Internal Medicine, Wakayama Medical University, 811-1 Kimiidera, Wakayama City, Wakayama, 641-0012, Japan
| | - Toshio Shimokawa
- Clinical Study Support Center, Wakayama Medical University, Wakayama, Japan
| | - Masayuki Kitano
- Second Department of Internal Medicine, Wakayama Medical University, 811-1 Kimiidera, Wakayama City, Wakayama, 641-0012, Japan.
| |
Collapse
|
6
|
Giri S, Mohan BP, Jearth V, Kale A, Angadi S, Afzalpurkar S, Harindranath S, Sundaram S. Adverse events with EUS-guided biliary drainage: a systematic review and meta-analysis. Gastrointest Endosc 2023; 98:515-523.e18. [PMID: 37392952 DOI: 10.1016/j.gie.2023.06.055] [Citation(s) in RCA: 23] [Impact Index Per Article: 11.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/06/2023] [Revised: 06/01/2023] [Accepted: 06/20/2023] [Indexed: 07/03/2023]
Abstract
BACKGROUND AND AIMS Multiple meta-analyses have evaluated the technical and clinical success of EUS-guided biliary drainage (BD), but meta-analyses concerning adverse events (AEs) are limited. The present meta-analysis analyzed AEs associated with various types of EUS-BD. METHODS A literature search of MEDLINE, Embase, and Scopus was conducted from 2005 to September 2022 for studies analyzing the outcome of EUS-BD. The primary outcomes were incidence of overall AEs, major AEs, procedure-related mortality, and reintervention. The event rates were pooled using a random-effects model. RESULTS One hundred fifty-five studies (7887 patients) were included in the final analysis. The pooled clinical success rates and incidence of AEs with EUS-BD were 95% (95% confidence interval [CI], 94.1-95.9) and 13.7% (95% CI, 12.3-15.0), respectively. Among early AEs, bile leak was the most common followed by cholangitis with pooled incidences of 2.2% (95% CI, 1.8-2.7) and 1.0% (95% CI, .8-1.3), respectively. The pooled incidences of major AEs and procedure-related mortality with EUS-BD were .6% (95% CI, .3-.9) and .1% (95% CI, .0-.4), respectively. The pooled incidences of delayed migration and stent occlusion were 1.7% (95% CI, 1.1-2.3) and 11.0% (95% CI, 9.3-12.8), respectively. The pooled event rate for reintervention (for stent migration or occlusion) after EUS-BD was 16.2% (95% CI, 14.0-18.3; I2 = 77.5%). CONCLUSIONS Despite a high clinical success rate, EUS-BD may be associated with AEs in one-seventh of the cases. However, major AEs and mortality incidence remain less than 1%, which is reassuring.
Collapse
Affiliation(s)
- Suprabhat Giri
- Department of Gastroenterology, Nizam's Institute of Medical Sciences, Hyderabad, India
| | - Babu P Mohan
- Department of Gastroenterology, University of Utah, Salt Lake City, Utah, USA
| | - Vaneet Jearth
- Department of Gastroenterology, Post Graduate Institute of Medical Education & Research, Chandigarh, India
| | - Aditya Kale
- Department of Gastroenterology, Seth GS Medical College and KEM Hospital, Mumbai, India
| | - Sumaswi Angadi
- Department of Gastroenterology, Nizam's Institute of Medical Sciences, Hyderabad, India
| | - Shivaraj Afzalpurkar
- Department of Gastroenterology, Nanjappa Multispecialty Hospital, Davanagere, India
| | - Sidharth Harindranath
- Department of Gastroenterology, Seth GS Medical College and KEM Hospital, Mumbai, India
| | - Sridhar Sundaram
- Department of Digestive Diseases and Clinical Nutrition, Tata Memorial Hospital, Homi Bhabha National Institute, Mumbai, India
| |
Collapse
|
7
|
Koga T, Hijioka S, Nagashio Y, Maruki Y, Maehara K, Murashima Y, Kawasaki Y, Takeshita K, Yamada N, Yoshinari M, Hisada Y, Harai S, Kitamura H, Kawahara S, Ohba A, Morizane C, Ishida Y, Hirai F, Okusaka T. Prospective clinical trial of EUS-guided choledochoduodenostomy without fistula dilation for malignant distal biliary obstruction. Endosc Ultrasound 2023; 12:409-416. [PMID: 37969165 PMCID: PMC10631599 DOI: 10.1097/eus.0000000000000009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/07/2022] [Accepted: 04/12/2023] [Indexed: 11/17/2023] Open
Abstract
Background and Objectives During EUS-guided choledochoduodenostomy (EUS-CDS), fistula dilation before stent insertion is associated with adverse events (AEs), such as bile leakage and peritonitis. We hypothesized that EUS-CDS without fistula dilation using a novel self-expandable metal stent (SEMS) with a thin delivery system could overcome this problem, and we conducted this study to evaluate its feasibility and safety. Methods This was an open-label, single-arm, phase II study at a single institution. We planned EUS-CDS without fistula dilation using a fully covered SEMS with a 5.9-Fr delivery system for unresectable malignant distal biliary obstruction. The primary outcome was overall technical success. Secondary outcomes were technical success without fistula dilation, procedure time, functional success, time to recurrent biliary obstruction, and AEs. The planned sample size was 25 patients. Results In total, 24 patients were included in this study. In 21 patients, EUS-CDS was performed as primary drainage. The overall technical success rate was 100% (24 of 24 patients). The technical success rate without fistula dilation was 96% (23 of 24). The median procedure time was 16 min (range, 10-66 min). The functional success rate was 96% (23 of 24). The median time to recurrent biliary obstruction was 148 days (95% confidence interval, 29-266 days). There were no procedure-related AEs. Furthermore, computed tomography immediately after the procedure showed no leakage of contrast medium into the abdominal cavity in any patient. Conclusions EUS-guided choledochoduodenostomy without fistula dilation using a fully covered SEMS with a 5.9-Fr delivery system is feasible with a high probability and can be achieved quickly while effectively preventing bile leakage and peritonitis.
Collapse
Affiliation(s)
- Takehiko Koga
- Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital, 5-1-1 Tsukiji, Chuo-ku, Tokyo 104-0045, Japan
- Department of Gastroenterology and Medicine, Faculty of Medicine, Fukuoka University, 7-45-1 Nanakuma, Johnan-ku, Fukuoka, 814-0180, Japan
| | - Susumu Hijioka
- Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital, 5-1-1 Tsukiji, Chuo-ku, Tokyo 104-0045, Japan
| | - Yoshikuni Nagashio
- Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital, 5-1-1 Tsukiji, Chuo-ku, Tokyo 104-0045, Japan
| | - Yuta Maruki
- Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital, 5-1-1 Tsukiji, Chuo-ku, Tokyo 104-0045, Japan
| | - Kosuke Maehara
- Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital, 5-1-1 Tsukiji, Chuo-ku, Tokyo 104-0045, Japan
| | - Yumi Murashima
- Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital, 5-1-1 Tsukiji, Chuo-ku, Tokyo 104-0045, Japan
| | - Yuki Kawasaki
- Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital, 5-1-1 Tsukiji, Chuo-ku, Tokyo 104-0045, Japan
| | - Kotaro Takeshita
- Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital, 5-1-1 Tsukiji, Chuo-ku, Tokyo 104-0045, Japan
| | - Natsumi Yamada
- Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital, 5-1-1 Tsukiji, Chuo-ku, Tokyo 104-0045, Japan
| | - Motohiro Yoshinari
- Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital, 5-1-1 Tsukiji, Chuo-ku, Tokyo 104-0045, Japan
| | - Yuya Hisada
- Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital, 5-1-1 Tsukiji, Chuo-ku, Tokyo 104-0045, Japan
| | - Shota Harai
- Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital, 5-1-1 Tsukiji, Chuo-ku, Tokyo 104-0045, Japan
| | - Hidetoshi Kitamura
- Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital, 5-1-1 Tsukiji, Chuo-ku, Tokyo 104-0045, Japan
| | - Shun Kawahara
- Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital, 5-1-1 Tsukiji, Chuo-ku, Tokyo 104-0045, Japan
| | - Akihiro Ohba
- Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital, 5-1-1 Tsukiji, Chuo-ku, Tokyo 104-0045, Japan
| | - Chigusa Morizane
- Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital, 5-1-1 Tsukiji, Chuo-ku, Tokyo 104-0045, Japan
| | - Yusuke Ishida
- Department of Gastroenterology and Medicine, Faculty of Medicine, Fukuoka University, 7-45-1 Nanakuma, Johnan-ku, Fukuoka, 814-0180, Japan
| | - Fumihito Hirai
- Department of Gastroenterology and Medicine, Faculty of Medicine, Fukuoka University, 7-45-1 Nanakuma, Johnan-ku, Fukuoka, 814-0180, Japan
| | - Takuji Okusaka
- Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital, 5-1-1 Tsukiji, Chuo-ku, Tokyo 104-0045, Japan
| |
Collapse
|
8
|
Itonaga M, Kitano M, Ashida R. Development of devices for interventional endoscopic ultrasound for the management of pancreatobiliary diseases. Dig Endosc 2023; 35:302-313. [PMID: 36052861 DOI: 10.1111/den.14428] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/15/2022] [Accepted: 08/30/2022] [Indexed: 02/08/2023]
Abstract
A variety of devices have been developed for interventional endoscopic ultrasound (EUS). EUS-guided drainage of the bile duct and pancreatic duct, as well as fluid collection adjacent to the gastrointestinal tract, is performed by a procedure involving puncture, guidewire manipulation, tract dilation, and stent placement. Devices specialized for interventional EUS are being developed for each step of the procedure. Mechanical dilators such as bougie, balloon, and electrocautery dilators are used for tract dilation. Various types of plastic stents, self-expandable metal stents, and lumen-apposing metal stents specifically designed for interventional EUS are now available, including one-step devices developed to improve the efficacy and safety of interventional EUS. In addition, radiofrequency ablation and the placement of fiducial markers and radioactive seeds under EUS guidance are now becoming established for pancreatic neoplasms. Such development of specialized devices has expanded the indications for interventional EUS, increased the success rate, and lowered the adverse event rate.
Collapse
Affiliation(s)
- Masahiro Itonaga
- Second Department of Internal Medicine, Wakayama Medical University, Wakayama, Japan
| | - Masayuki Kitano
- Second Department of Internal Medicine, Wakayama Medical University, Wakayama, Japan
| | - Reiko Ashida
- Second Department of Internal Medicine, Wakayama Medical University, Wakayama, Japan
| |
Collapse
|