1
|
Cappelle D, De Keukeleire S, Neels H, Been F, De Doncker M, Dom G, Crunelle CL, Covaci A, van Nuijs ALN. Keratinous matrices for the assessment of drugs of abuse consumption: A correlation study between hair and nails. Drug Test Anal 2018; 10:1110-1118. [PMID: 29314761 DOI: 10.1002/dta.2356] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2017] [Revised: 12/22/2017] [Accepted: 12/24/2017] [Indexed: 02/05/2023]
Abstract
Keratinous matrices - hair and nails - accumulate substances over time and allow retrospective investigation of past consumption. Analysis of these matrices can provide information complementary to blood and urine analysis or can be used as standalone. So far, research has primarily focused on the detection of substances in hair, while studies in nails are scarce. In this study, we assessed concentrations of drugs of abuse and their metabolites in hair, fingernails, and toenails collected from the same individuals to evaluate differences and correlations between matrices. A total of 26 hair, 24 fingernail, and 18 toenail samples were collected. Samples were analysed by a validated liquid chromatography-tandem mass spectrometry method able to simultaneously detect the following compounds: amphetamine (AMP), methamphetamine, 3,4-methylenedioxymethamphetamine (MDMA), 3,4-methylenedioxyethylamphetamine, morphine (MOR), codeine (COD), 6-monoacetylmorphine (6-MAM), methadone (MTD), 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine (EDDP), cocaine (COC), benzoylecgonine (BE), and ecgonine methyl ester (EME). Strong positive correlations between hair, fingernails, and toenails were present for COC, BE, EME, AMP and MDMA. MOR, COD, 6-MAM, MTD and EDDP showed positive trends. Concentrations were generally higher in nails compared to hair. Ratios between parent compounds and their metabolites were assessed for 6-MAM/MOR, EDDP/MTD, BE/COC and EME/COC. Preliminary cut-off concentrations for COC, BE, EME and AMP in fingernails and toenails were proposed. In light of these results, nails can be considered as a useful alternative to hair for monitoring of long-term drug consumption. However, care should be taken regarding the variability in the accumulation of compounds between the matrices.
Collapse
Affiliation(s)
| | | | - Hugo Neels
- Toxicological Centre, University of Antwerp, Belgium
| | - Frederic Been
- Toxicological Centre, University of Antwerp, Belgium
| | | | - Geert Dom
- Collaborative Antwerp Psychiatric Research Institute, University of Antwerp, Belgium
- Psychiatric Hospital Multiversum, Boechout, Belgium
| | - Cleo L Crunelle
- Toxicological Centre, University of Antwerp, Belgium
- Department of Psychiatry, Vrije Universiteit Brussel (VUB), Universitair Ziekenhuis Brussel (UZ Brussel), Jette, Belgium
| | - Adrian Covaci
- Toxicological Centre, University of Antwerp, Belgium
| | | |
Collapse
|
2
|
Slawson MH, Johnson-Davis KL. Quantitation of Ethyl Glucuronide and Ethyl Sulfate in Urine Using Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS). Methods Mol Biol 2016; 1383:167-75. [PMID: 26660185 DOI: 10.1007/978-1-4939-3252-8_18] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
Ethyl glucuronide and ethyl sulfate are minor conjugated metabolites of ethanol that can be detected in urine for several days after last ingestion of ethanol. The monitoring of ethanol use has both clinical and forensic applications and a longer detection window afforded by monitoring these metabolites is obvious. LC-MS/MS is used to analyze diluted urine with deuterated analogs of each analyte as internal standards to ensure accurate quantitation and control for any potential matrix effects. High aqueous HPLC is used to chromatograph the metabolites. Negative ion electrospray is used to introduce the metabolites into the mass spectrometer. Selected reaction monitoring of two product ions for each analyte allows for the calculation of ion ratios which ensures correct identification of each metabolite, while a matrix-matched calibration curve is used for quantitation.
Collapse
Affiliation(s)
- Matthew H Slawson
- ARUP Institute for Clinical and Experimental Pathology, 500 Chipeta Way, Salt Lake City, 84108, UT, USA
- ARUP Laboratories, Salt Lake City, UT, USA
| | - Kamisha L Johnson-Davis
- Department of Pathology, University of Utah Health Sciences Center, School of Medicine, ARUP Institute for Clinical and Experimental Pathology, 500 Chipeta Way, Salt Lake City, 84108, UT, USA.
| |
Collapse
|
3
|
Suwannachom N, Thananchai T, Junkuy A, O’Brien TE, Sribanditmongkol P. Duration of detection of methamphetamine in hair after abstinence. Forensic Sci Int 2015. [DOI: 10.1016/j.forsciint.2015.06.030] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
4
|
Suesse S, Blueml M, Pragst F. Effect of the analyzed hair length on fatty acid ethyl ester (FAEE) concentrations in hair – Is there congruence of cut-offs for 0–3 and 0–6 cm hair segments? Forensic Sci Int 2015; 249:1-5. [DOI: 10.1016/j.forsciint.2014.11.020] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2014] [Revised: 11/21/2014] [Accepted: 11/24/2014] [Indexed: 11/30/2022]
|
5
|
Jakobsson G, Kronstrand R. Segmental analysis of amphetamines in hair using a sensitive UHPLC-MS/MS method. Drug Test Anal 2015; 6 Suppl 1:22-9. [PMID: 24817045 DOI: 10.1002/dta.1637] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2013] [Revised: 01/16/2014] [Accepted: 02/14/2014] [Indexed: 02/05/2023]
Abstract
A sensitive and robust ultra high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method was developed and validated for quantification of amphetamine, methamphetamine, 3,4-methylenedioxyamphetamine and 3,4-methylenedioxy methamphetamine in hair samples. Segmented hair (10 mg) was incubated in 2M sodium hydroxide (80°C, 10 min) before liquid-liquid extraction with isooctane followed by centrifugation and evaporation of the organic phase to dryness. The residue was reconstituted in methanol:formate buffer pH 3 (20:80). The total run time was 4 min and after optimization of UHPLC-MS/MS-parameters validation included selectivity, matrix effects, recovery, process efficiency, calibration model and range, lower limit of quantification, precision and bias. The calibration curve ranged from 0.02 to 12.5 ng/mg, and the recovery was between 62 and 83%. During validation the bias was less than ±7% and the imprecision was less than 5% for all analytes. In routine analysis, fortified control samples demonstrated an imprecision <13% and control samples made from authentic hair demonstrated an imprecision <26%. The method was applied to samples from a controlled study of amphetamine intake as well as forensic hair samples previously analyzed with an ultra high performance liquid chromatography time of flight mass spectrometry (UHPLC-TOF-MS) screening method. The proposed method was suitable for quantification of these drugs in forensic cases including violent crimes, autopsy cases, drug testing and re-granting of driving licences. This study also demonstrated that if hair samples are divided into several short segments, the time point for intake of a small dose of amphetamine can be estimated, which might be useful when drug facilitated crimes are investigated.
Collapse
Affiliation(s)
- Gerd Jakobsson
- Department of Forensic Genetics and Forensic Toxicology, National Board of Forensic Medicine, SE-58758, Linköping, Sweden
| | | |
Collapse
|
6
|
Cannabinoid findings in children hair - what do they really tell us? An assessment in the light of three different analytical methods with focus on interpretation of Δ9-tetrahydrocannabinolic acid A concentrations. Drug Test Anal 2014; 7:349-57. [DOI: 10.1002/dta.1692] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2014] [Revised: 05/08/2014] [Accepted: 06/14/2014] [Indexed: 11/07/2022]
|
7
|
|
8
|
Agius R, Dufaux B, Kahl HG, Nadulski T. Is urine an alternative to cosmetically treated hair for the detection of drugs and alcohol? Drug Test Anal 2014; 6 Suppl 1:120-2. [DOI: 10.1002/dta.1629] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2013] [Revised: 01/27/2014] [Accepted: 01/27/2014] [Indexed: 11/10/2022]
Affiliation(s)
- Ronald Agius
- Department of Forensic and Clinical Toxicology; Siemensstrasße 40, 32105 Bad Salzuflen Germany
| | - Bertin Dufaux
- Department of Forensic and Clinical Toxicology; Siemensstrasße 40, 32105 Bad Salzuflen Germany
| | - Hans-Gerhard Kahl
- Department of Forensic and Clinical Toxicology; Siemensstrasße 40, 32105 Bad Salzuflen Germany
| | - Thomas Nadulski
- Department of Forensic and Clinical Toxicology; Siemensstrasße 40, 32105 Bad Salzuflen Germany
| |
Collapse
|
9
|
Agius R, Nadulski T. Utility of ELISA screening for the monitoring of abstinence from illegal and legal drugs in hair and urine. Drug Test Anal 2014; 6 Suppl 1:101-9. [DOI: 10.1002/dta.1644] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2013] [Revised: 01/29/2014] [Accepted: 02/16/2014] [Indexed: 11/10/2022]
Affiliation(s)
- Ronald Agius
- Department of Forensic and Clinical Toxicology; Siemensstraße 40 32105 Bad Salzuflen Germany
| | - Thomas Nadulski
- Department of Forensic and Clinical Toxicology; Siemensstraße 40 32105 Bad Salzuflen Germany
| |
Collapse
|
10
|
Abstract
This review focuses on alcohol and substance abuse in the context of solid-organ transplantation. Alcohol and substance abuse are common and may lead to a need for solid-organ transplantation and may also contribute to significant physical and psychologic problems that impact upon the recipient. Damaging levels of alcohol intake can occur in the absence of dependence. Alcohol or substance abuse after transplantation is associated with poor medication compliance and this may increase risk of graft loss. Intravenous drug use is associated with increased risk of infections (especially secondary to opportunistic organisms-bacterial, viral, protozoal, and others-and such infections may be more severe in the immunosuppressed), but there is only anecdotal evidence that such behavior has a worse outcome in transplant recipients. Whereas previous alcohol excess and drug use in kidney recipients are both associated with a small but statistically significantly increased risk of adverse outcomes (hazard ratio, 1.16-1.56), alcohol use within recommended guidelines after transplantation appears safe and possibly beneficial. Robust data are lacking for other organs, but those available suggest that heart transplantation is safe in individuals with a history of alcohol or substance abuse. Health specialists in drug or alcohol addiction should carefully screen all potential transplant candidates for these conditions, and where there is evidence of dependency or abuse, effective psychologic and physical treatment should be offered. Studies have shown that interventions such as psychologic intervention have improved alcohol behavior in the context of liver transplantation. Although there are no comparable studies with other solid-organ recipients, it is reasonable to expect transferable outcomes.
Collapse
|
11
|
Marques PR, Tippetts AS, Yegles M. Ethylglucuronide in hair is a top predictor of impaired driving recidivism, alcohol dependence, and a key marker of the highest BAC interlock tests. TRAFFIC INJURY PREVENTION 2014; 15:361-369. [PMID: 24471360 DOI: 10.1080/15389588.2013.824569] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
OBJECTIVES This study focuses on the predictive and comparative significance of ethyl glucuronide measured in head hair (hEtG) for estimating risks associated with alcohol-impaired driving offenders. Earlier work compared different alcohol biomarkers for estimating rates of failed blood alcohol concentration (BAC) tests logged during 8 months of interlock participation. These analyses evaluate the comparative performance of several alcohol markers including hEtG and other markers, past driver records, and psychometric assessment predictors for the detection of 4 criteria: new driving under the influence (DUI) recidivism, alcohol dependence, and interlock record variables including fail rates and maximal interlock BACs logged. METHODS Drivers charged with alcohol impairment (DUI) in Alberta, Canada (n = 534; 64% first offenders, 36% multiple offenders) installed ignition interlock devices and consented to participate in research to evaluate blood-, hair-, and urine-derived alcohol biomarkers; sit for interviews; take psychometric assessments; and permit analyses of driving records and interlock log files. Subject variables included demographics, alcohol dependence at program entry, preprogram prior DUI convictions, postenrollment new DUI convictions, self-reported drinking assessments, morning and overall rates of failed interlock BAC tests, and maximal interlock BAC readings. Recidivism, dependence, high BAC, and combined fail rates were set as criteria; other variables were set as predictors. Area under the receiver operating characteristics (ROC) curve (A') estimates of sensitivity and specificity were calculated. Additional analyses were conducted on baseline hEtG levels. Driver performance and drinking indicators were evaluated against the standard hEtG cutoff for excessive drinking at (30 pg/mg) and a higher criterion of 50 pg/mg. HEtG splits were evaluated with the Mann-Whitney rank statistic. RESULTS HEtG emerged as a top overall predictor for discriminating new recidivism events that occur after interlock installation, for entry alcohol dependence, and for the highest interlock BACs recorded. Together, hEtG and phosphatidylethanol (PEth) were the top predictors of all criterion measures. By contrast, the hair-derived alcohol biomarkers hEtG and hFAEE (fatty acid ethyl esters) were poorer than other alcohol biomarkers as detectors of interlock BAC test fail rates. CONCLUSIONS This study showed that hEtG, an objective alternative to often unreliable self-reported past representation of drinking levels, yields crucial insight into driver alcohol-related risks early in an interlock program and is a top predictor of new recidivist events. Together with PEth, these markers would be excellent anchors in a panel for detecting alcohol consumption.
Collapse
Affiliation(s)
- Paul R Marques
- a Pacific Institute for Research and Evaluation , Calverton , Maryland
| | | | | |
Collapse
|
12
|
Development and validation of a single LC-MS/MS assay following SPE for simultaneous hair analysis of amphetamines, opiates, cocaine and metabolites. Forensic Sci Int 2013; 234:132-8. [PMID: 24378313 DOI: 10.1016/j.forsciint.2013.11.004] [Citation(s) in RCA: 55] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2013] [Revised: 10/28/2013] [Accepted: 11/06/2013] [Indexed: 10/26/2022]
Abstract
The two major challenges in hair analysis are the limited amount of samples usually available and the low targeted concentrations. To overcome these limitations, a liquid chromatography-electrospray-tandem mass spectrometry method (LC-ESI-MS/MS) allowing the simultaneous analysis of 17 amphetamines (amphetamine, BDB, m-CPP, dexfenfluramine, DOB, DOM, ephedrine, MBDB, MDA, MDEA, MDMA, methamphetamine, methylphenidate, 4-MTA, norephedrine, norfenfluramine and PMA), 5 opiates (morphine, codeine, heroin, ethylmorphine, and 6AM), cocaine and 5 metabolites [ecgonine methyl ester (EME), benzoylecgonine (BZE), anhydroecgonine methyl ester (AME), cocaethylene, and norcocaine] has been developed. The validation procedure included linearity, intra-day and inter-day variability and accuracy for 5 days (5 replicates at 3 concentration levels). Proficiency studies were used to check the accuracy of the method. As a result, all amphetamines, opiates and cocaine derivatives were satisfactory identified by 2 MRM transitions in 15 min. Calibration curves were performed by a quadratic 1/X weighted regression. The calibration model fits from 0.05 to 10 ng/mg. The limits of detection (LODs) range between 0.005 and 0.030 ng/mg. Precision has been checked by intra-day and inter-day RSD, and associated relative bias, which were lower than 25% for the limits of quantifications (LOQs) and lower than 20% for the other levels tested. This method was routinely applied to hair samples: two positive results of adult drug addicts are presented.
Collapse
|
13
|
Agius R, Nadulski T, Kahl HG, Dufaux B. Comparison of LUCIO®-direct ELISA with CEDIA immunoassay for 'zero tolerance' drug screening in urine as required by the German re-licensing guidelines. Drug Test Anal 2013; 5:390-9. [PMID: 23349145 DOI: 10.1002/dta.1455] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2012] [Revised: 12/07/2012] [Accepted: 12/09/2012] [Indexed: 11/06/2022]
Abstract
The performance of the previously validated LUCIO(®)-Direct-enzyme linked immunosorbent assay (direct ELISA) screening tests according to forensic guidelines is compared to that of cloned enzyme donor immunoassays (CEDIA) test for drugs of abuse in urine as defined in the new re-licensing German medical and psychological assessment (MPA) guidelines. The MPA screening cut-offs correspond to 10 ng/ml 11-nor-delta-9-tetrahydrocannabinol-9-carboxylic acid (THC-COOH), 50 ng/ml amphetamine and designer amphetamines, 25 ng/ml morphine, codeine and dihydrocodeine, 30 ng/ml benzoylecgonine, 50 ng/ml methadone metabolite, 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine (EDDP) and metabolites of diazepam, oxazepam, bromazepam, alprazolam, flunitrazepam and lorazepam at 50 ng/ml. Average relative sensitivities and relative specificities were 99.7 % and 98.4 % for direct ELISA and 66 % and 91.4 % for CEDIA, respectively.
Collapse
Affiliation(s)
- Ronald Agius
- Labor Krone, Siemensstr. 40, D-32105, Bad Salzuflen, Germany.
| | | | | | | |
Collapse
|