1
|
Yuan Z, Ding J, Zhang Y, Huang B, Song Z, Meng X, Ma X, Gong X, Huang Z, Ma S, Xiang S, Xu W. Components, mechanisms and applications of stimuli-responsive polymer gels. Eur Polym J 2022. [DOI: 10.1016/j.eurpolymj.2022.111473] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
2
|
Beck JG, Skuratovsky A, Granger MC, Porter MD. Calibrant-Free Analyte Quantitation via a Variable Velocity Flow Cell. Anal Chem 2016; 89:1147-1154. [PMID: 27935676 DOI: 10.1021/acs.analchem.6b03527] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
In this paper, we describe a novel method for analyte quantitation that does not rely on calibrants, internal standards, or calibration curves but, rather, leverages the relationship between disparate and predictable surface-directed analyte flux to an array of sensing addresses and a measured resultant signal. To reduce this concept to practice, we fabricated two flow cells such that the mean linear fluid velocity, U, was varied systematically over an array of electrodes positioned along the flow axis. This resulted in a predictable variation of the address-directed flux of a redox analyte, ferrocenedimethanol (FDM). The resultant limiting currents measured at a series of these electrodes, and accurately described by a convective-diffusive transport model, provided a means to calculate an "unknown" concentration without the use of calibrants, internal standards, or a calibration curve. Furthermore, the experiment and concentration calculation only takes minutes to perform. Deviation in calculated FDM concentrations from true values was minimized to less than 0.5% when empirically derived values of U were employed.
Collapse
Affiliation(s)
- Jason G Beck
- Department of Chemistry, University of Utah , Salt Lake City, Utah 84112, United States.,Nano Institute of Utah, University of Utah , Salt Lake City, Utah 84112, United States
| | - Aleksander Skuratovsky
- Department of Chemical Engineering, University of Utah , Salt Lake City, Utah 84112, United States.,Nano Institute of Utah, University of Utah , Salt Lake City, Utah 84112, United States
| | - Michael C Granger
- Department of Chemical Engineering, University of Utah , Salt Lake City, Utah 84112, United States.,Nano Institute of Utah, University of Utah , Salt Lake City, Utah 84112, United States.,Department of Surgery, School of Medicine, University of Utah , Salt Lake City, Utah 84112, United States
| | - Marc D Porter
- Department of Chemistry, University of Utah , Salt Lake City, Utah 84112, United States.,Department of Chemical Engineering, University of Utah , Salt Lake City, Utah 84112, United States.,Departments of Bioengineering and Pathology, University of Utah , Salt Lake City, Utah 84112, United States.,Nano Institute of Utah, University of Utah , Salt Lake City, Utah 84112, United States
| |
Collapse
|
3
|
Fortgang P, Tite T, Barnier V, Zehani N, Maddi C, Lagarde F, Loir AS, Jaffrezic-Renault N, Donnet C, Garrelie F, Chaix C. Robust Electrografting on Self-Organized 3D Graphene Electrodes. ACS APPLIED MATERIALS & INTERFACES 2016; 8:1424-1433. [PMID: 26710829 DOI: 10.1021/acsami.5b10647] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
Improving graphene-based electrode fabrication processes and developing robust methods for its functionalization are two key research routes to develop new high-performance electrodes for electrochemical applications. Here, a self-organized three-dimensional (3D) graphene electrode processed by pulsed laser deposition with thermal annealing is reported. This substrate shows great performance in electron transfer kinetics regarding ferrocene redox probes in solution. A robust electrografting strategy for covalently attaching a redox probe onto these graphene electrodes is also reported. The modification protocol consists of a combination of diazonium salt electrografting and click chemistry. An alkyne-terminated phenyl ring is first electrografted onto the self-organized 3D graphene electrode by in situ electrochemical reduction of 4-ethynylphenyl diazonium. Then the ethynylphenyl-modified surface efficiently reacts with the redox probe bearing a terminal azide moiety (2-azidoethyl ferrocene) by means of Cu(I)-catalyzed alkyne-azide cycloaddition. Our modification strategy applied to 3D graphene electrodes was analyzed by means of atomic force microscopy, scanning electron microscopy, Raman spectroscopy, cyclic voltammetry, and X-ray photoelectron spectroscopy (XPS). For XPS chemical surface analysis, special attention was paid to the distribution and chemical state of iron and nitrogen in order to highlight the functionalization of the graphene-based substrate by electrochemically grafting a ferrocene derivative. Dense grafting was observed, offering 4.9 × 10(-10) mol cm(-2) surface coverage and showing a stable signal over 22 days. The electrografting was performed in the form of multilayers, which offers higher ferrocene loading than a dense monolayer on a flat surface. This work opens highly promising perspectives for the development of self-organized 3D graphene electrodes with various sensing functionalities.
Collapse
Affiliation(s)
- Philippe Fortgang
- Institut des Sciences Analytiques, UMR 5280, CNRS, Université de Lyon 1 , 5 rue de la Doua, 69100 Villeurbanne, France
| | - Teddy Tite
- Université de Lyon , F-69003, Lyon, France
- Université de Saint-Étienne , Laboratoire Hubert Curien (UMR 5516 CNRS), 42000 Saint-Étienne, France
| | - Vincent Barnier
- Laboratoire Georges Friedel, Ecole Nationale Supérieure des Mines , 42023 Saint-Etienne, France
| | - Nedjla Zehani
- Institut des Sciences Analytiques, UMR 5280, CNRS, Université de Lyon 1 , 5 rue de la Doua, 69100 Villeurbanne, France
| | - Chiranjeevi Maddi
- Université de Lyon , F-69003, Lyon, France
- Université de Saint-Étienne , Laboratoire Hubert Curien (UMR 5516 CNRS), 42000 Saint-Étienne, France
| | - Florence Lagarde
- Institut des Sciences Analytiques, UMR 5280, CNRS, Université de Lyon 1 , 5 rue de la Doua, 69100 Villeurbanne, France
| | - Anne-Sophie Loir
- Université de Lyon , F-69003, Lyon, France
- Université de Saint-Étienne , Laboratoire Hubert Curien (UMR 5516 CNRS), 42000 Saint-Étienne, France
| | - Nicole Jaffrezic-Renault
- Institut des Sciences Analytiques, UMR 5280, CNRS, Université de Lyon 1 , 5 rue de la Doua, 69100 Villeurbanne, France
| | - Christophe Donnet
- Université de Lyon , F-69003, Lyon, France
- Université de Saint-Étienne , Laboratoire Hubert Curien (UMR 5516 CNRS), 42000 Saint-Étienne, France
| | - Florence Garrelie
- Université de Lyon , F-69003, Lyon, France
- Université de Saint-Étienne , Laboratoire Hubert Curien (UMR 5516 CNRS), 42000 Saint-Étienne, France
| | - Carole Chaix
- Institut des Sciences Analytiques, UMR 5280, CNRS, Université de Lyon 1 , 5 rue de la Doua, 69100 Villeurbanne, France
| |
Collapse
|
4
|
Han D, Kim YR, Kang CM, Chung TD. Electrochemical signal amplification for immunosensor based on 3D interdigitated array electrodes. Anal Chem 2014; 86:5991-8. [PMID: 24842332 DOI: 10.1021/ac501120y] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/18/2023]
Abstract
We devised an electrochemical redox cycling based on three-dimensional interdigitated array (3D IDA) electrodes for signal amplification to enhance the sensitivity of chip-based immunosensors. The 3D IDA consists of two closely spaced parallel indium tin oxide (ITO) electrodes that are positioned not only on the bottom but also the ceiling, facing each other along a microfluidic channel. We investigated the signal intensities from various geometric configurations: Open-2D IDA, Closed-2D IDA, and 3D IDA through electrochemical experiments and finite-element simulations. The 3D IDA among the four different systems exhibited the greatest signal amplification resulting from efficient redox cycling of electroactive species confined in the microchannel so that the faradaic current was augmented by a factor of ∼100. We exploited the enhanced sensitivity of the 3D IDA to build up a chronocoulometric immunosensing platform based on the sandwich enzyme-linked immunosorbent assay (ELISA) protocol. The mouse IgGs on the 3D IDA showed much lower detection limits than on the Closed-2D IDA. The detection limit for mouse IgG measured using the 3D IDA was ∼10 fg/mL, while it was ∼100 fg/mL for the Closed-2D IDA. Moreover, the proposed immunosensor system with the 3D IDA successfully worked for clinical analysis as shown by the sensitive detection of cardiac troponin I in human serum down to 100 fg/mL.
Collapse
Affiliation(s)
- Donghoon Han
- Department of Chemistry, Seoul National University , Seoul 151-747, Korea
| | | | | | | |
Collapse
|
5
|
Kleijn SE, Yanson AI, Koper MT. Electrochemical characterization of nano-sized gold electrodes fabricated by nano-lithography. J Electroanal Chem (Lausanne) 2012. [DOI: 10.1016/j.jelechem.2011.11.022] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/15/2022]
|
6
|
Hoeben FJM, Meijer FS, Dekker C, Albracht SPJ, Heering HA, Lemay SG. Toward single-enzyme molecule electrochemistry: [NiFe]-hydrogenase protein film voltammetry at nanoelectrodes. ACS NANO 2008; 2:2497-2504. [PMID: 19206284 DOI: 10.1021/nn800518d] [Citation(s) in RCA: 51] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
We have scaled down electrochemical assays of redox-active enzymes enabling us to study small numbers of molecules. Our approach is based on lithographically fabricated Au nanoelectrodes with dimensions down to ca. 70 x 70 nm(2). We first present a detailed characterization of the electrodes using a combination of scanning electron microscopy, cyclic voltammetry, and finite-element modeling. We then demonstrate the viability of the approach by focusing on the highly active [NiFe]-hydrogenase from Allochromatium vinosum immobilized on polymyxin-pretreated Au. Using this system, we successfully demonstrate a distinct catalytic response from less than 50 enzyme molecules. These results strongly suggest the feasibility of using bioelectrochemistry as a new tool for studying redox enzymes at the single-molecule level.
Collapse
Affiliation(s)
- Freek J M Hoeben
- Kavli Institute of Nanoscience, Delft University of Technology, Lorentzweg 1, Delft, The Netherlands
| | | | | | | | | | | |
Collapse
|
7
|
Bergren AJ, Porter MD. Selectivity mechanisms at self-assembled monolayers on gold: Implications in redox recycling amplification systems. J Electroanal Chem (Lausanne) 2007. [DOI: 10.1016/j.jelechem.2006.07.042] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
8
|
Krapf D, Quinn BM, Wu MY, Zandbergen HW, Dekker C, Lemay SG. Experimental observation of nonlinear ionic transport at the nanometer scale. NANO LETTERS 2006; 6:2531-5. [PMID: 17090086 DOI: 10.1021/nl0619453] [Citation(s) in RCA: 29] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/12/2023]
Abstract
Nanometer-sized electrodes are used to probe the transport of ions in liquid by monitoring heterogeneous electrochemical reactions. We observe pronounced nonlinearities of ion flux versus concentration when transport is localized within a region smaller than 10 nm. We show that these observations cannot be explained using conventional continuum, mean-field descriptions of ionic transport. The data indicate that these deviations are caused by the high flux of charged species that is achieved at nanometer-sized electrodes.
Collapse
Affiliation(s)
- Diego Krapf
- Kavli Institute of Nanoscience, Delft University of Technology, Lorentzweg 1, 2628 CJ Delft, The Netherlands
| | | | | | | | | | | |
Collapse
|
9
|
Aoki K. Rotational diffusion current of multi-charged redox species by means of Monte Carlo simulation. Electrochim Acta 2006. [DOI: 10.1016/j.electacta.2005.11.051] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
|
10
|
Aoki K. Is Voltammetric Current Proportional to the Number of Transferred Electrons for Multi-Charged Ions or to 3/2 Power of the Number? ELECTROANAL 2005. [DOI: 10.1002/elan.200403285] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
|
11
|
Kazimierska E, Ciszkowska M. Thermoresponsive Poly-N-isopropylacrylamide Gels Modified with Colloidal Gold Nanoparticles for Electroanalytical Applications. 1. Preparation and Characterization. ELECTROANAL 2005. [DOI: 10.1002/elan.200503286] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|