• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4616374)   Today's Articles (3144)   Subscriber (49395)
For: Gómez-Caballero A, Unceta N, Goicolea M, Barrio R. Voltammetric Determination of Metamitron with an Electrogenerated Molecularly Imprinted Polymer Microsensor. ELECTROANAL 2007. [DOI: 10.1002/elan.200603731] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Number Cited by Other Article(s)
1
Bozal-Palabiyik B, Erkmen C, Uslu B. Molecularly Imprinted Electrochemical Sensors: Analytical and Pharmaceutical Applications Based on Ortho-Phenylenediamine Polymerization. CURR PHARM ANAL 2020. [DOI: 10.2174/1573412915666190304150159] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
2
Rational selection of the monomer for molecularly imprinted polymer preparation for selective and sensitive detection of 3-methylindole in water. J Electroanal Chem (Lausanne) 2019. [DOI: 10.1016/j.jelechem.2018.10.043] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
3
Anirudhan TS, Alexander S. A potentiometric sensor for the trace level determination of hemoglobin in real samples using multiwalled carbon nanotube based molecular imprinted polymer. Eur Polym J 2017. [DOI: 10.1016/j.eurpolymj.2017.09.048] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
4
Said NM, Ogurtsov V, Twomey K, Nagle L, Herzog G. Chemically Modified Electrodes for Recessed Microelectrode Array. ACTA ACUST UNITED AC 2016. [DOI: 10.1016/j.proche.2016.07.002] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
5
Anirudhan TS, Alexander S. Selective determination of monosodium glutamate (Ajinomoto) in food samples using a potentiometric method with a modified multiwalled carbon nanotube based molecularly imprinted polymer. RSC Adv 2015. [DOI: 10.1039/c5ra17885a] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]  Open
6
Šelešovská R, Janíková L, Chýlková J. Green electrochemical sensors based on boron-doped diamond and silver amalgam for sensitive voltammetric determination of herbicide metamitron. MONATSHEFTE FUR CHEMIE 2014. [DOI: 10.1007/s00706-014-1372-9] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
7
Whitcombe MJ, Kirsch N, Nicholls IA. Molecular imprinting science and technology: a survey of the literature for the years 2004-2011. J Mol Recognit 2014;27:297-401. [PMID: 24700625 DOI: 10.1002/jmr.2347] [Citation(s) in RCA: 275] [Impact Index Per Article: 27.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2013] [Revised: 10/28/2013] [Accepted: 12/01/2013] [Indexed: 12/11/2022]
8
Anirudhan TS, Alexander S, Lilly A. Surface modified multiwalled carbon nanotube based molecularly imprinted polymer for the sensing of dopamine in real samples using potentiometric method. POLYMER 2014. [DOI: 10.1016/j.polymer.2014.07.057] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
9
A fast chiral sensing to DOPA enantiomers via poly-lysine films matrixes. Electrochim Acta 2013. [DOI: 10.1016/j.electacta.2013.09.123] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
10
A biomimetic potentiometric sensor based on molecularly imprinted polymer for the determination of memantine in tablets. Drug Test Anal 2012;5:461-7. [DOI: 10.1002/dta.371] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2011] [Revised: 09/10/2011] [Accepted: 09/11/2011] [Indexed: 11/07/2022]
11
Sharma PS, Pietrzyk-Le A, D’Souza F, Kutner W. Electrochemically synthesized polymers in molecular imprinting for chemical sensing. Anal Bioanal Chem 2012;402:3177-204. [PMID: 22302165 PMCID: PMC3303047 DOI: 10.1007/s00216-011-5696-6] [Citation(s) in RCA: 247] [Impact Index Per Article: 20.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2011] [Revised: 12/04/2011] [Accepted: 12/29/2011] [Indexed: 11/26/2022]
12
Molecular imprinting for selective chemical sensing of hazardous compounds and drugs of abuse. Trends Analyt Chem 2012. [DOI: 10.1016/j.trac.2011.11.005] [Citation(s) in RCA: 84] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
13
Voltammetric sensors with chiral recognition capability: The use of a chiral inducing agent in polyaniline electrochemical synthesis for the specific recognition of the enantiomers of the pesticide dinoseb. Electrochim Acta 2011. [DOI: 10.1016/j.electacta.2011.10.032] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
14
Malitesta C, Mazzotta E, Picca RA, Poma A, Chianella I, Piletsky SA. MIP sensors – the electrochemical approach. Anal Bioanal Chem 2011;402:1827-46. [DOI: 10.1007/s00216-011-5405-5] [Citation(s) in RCA: 236] [Impact Index Per Article: 18.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2011] [Revised: 08/05/2011] [Accepted: 09/08/2011] [Indexed: 10/17/2022]
15
Sadeghi HB, Ebrahimi SA, Tamaddon A, Bozorgvar F, Afifinia H, Almasian N, Mollaei S. Potentiometric Sensing of Lamotrigine Based on Molecularly Imprinted Polymers. ELECTROANAL 2011. [DOI: 10.1002/elan.201100140] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
16
Wu S, Tan W, Xu H. Protein molecularly imprinted polyacrylamide membrane: for hemoglobin sensing. Analyst 2010;135:2523-7. [PMID: 20625585 DOI: 10.1039/c0an00191k] [Citation(s) in RCA: 41] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
17
Plata MR, Contento AM, Ríos A. State-of-the-art of (bio)chemical sensor developments in analytical Spanish groups. SENSORS (BASEL, SWITZERLAND) 2010;10:2511-76. [PMID: 22319260 PMCID: PMC3274191 DOI: 10.3390/s100402511] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/23/2009] [Revised: 02/03/2010] [Accepted: 02/28/2010] [Indexed: 11/16/2022]
18
Gómez-Caballero A, Ugarte A, Sánchez-Ortega A, Unceta N, Goicolea MA, Barrio RJ. Molecularly imprinted poly[tetra(o-aminophenyl)porphyrin] as a stable and selective coating for the development of voltammetric sensors. J Electroanal Chem (Lausanne) 2010. [DOI: 10.1016/j.jelechem.2009.11.006] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
19
Review: Micro- and nanosized molecularly imprinted polymers for high-throughput analytical applications. Anal Chim Acta 2009;641:7-13. [DOI: 10.1016/j.aca.2009.03.035] [Citation(s) in RCA: 204] [Impact Index Per Article: 13.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2009] [Revised: 03/17/2009] [Accepted: 03/18/2009] [Indexed: 11/23/2022]
20
Javanbakht M, Eynollahi Fard S, Abdouss M, Mohammadi A, Reza Ganjali M, Norouzi P, Safaraliee L. A Biomimetic Potentiometric Sensor Using Molecularly Imprinted Polymer for the Cetirizine Assay in Tablets and Biological Fluids. ELECTROANAL 2008. [DOI: 10.1002/elan.200804284] [Citation(s) in RCA: 47] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
21
Molecularly imprinted polymer based potentiometric sensor for the determination of hydroxyzine in tablets and biological fluids. Anal Chim Acta 2008;612:65-74. [DOI: 10.1016/j.aca.2008.01.085] [Citation(s) in RCA: 94] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2007] [Revised: 01/27/2008] [Accepted: 01/30/2008] [Indexed: 11/24/2022]
PrevPage 1 of 1 1Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA