• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4635029)   Today's Articles (2100)   Subscriber (50012)
For: Canpolat E, Şar E, Coşkun N, Cankurtaran H. Determination of Trace Amounts of Copper in Tap Water Samples with a Calix[4]arene Modified Carbon Paste Electrode by Differential Pulse Anodic Stripping Voltammetry. ELECTROANAL 2007. [DOI: 10.1002/elan.200603829] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Number Cited by Other Article(s)
1
Partanen K, Pei Y, Hillen P, Hassan M, McEleney K, Schatte G, Payne SJ, Oleschuk R, She Z. Investigating electrochemical deposition of gold on commercial off-the-shelf 3-D printing materials towards developing sensing applications. RSC Adv 2022;12:33440-33448. [PMID: 36425202 PMCID: PMC9679451 DOI: 10.1039/d2ra05455h] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2022] [Accepted: 11/16/2022] [Indexed: 11/24/2022]  Open
2
Jin Mei C, Ainliah Alang Ahmad S. A review on the determination heavy metals ions using calixarene-based electrochemical sensors. ARAB J CHEM 2021. [DOI: 10.1016/j.arabjc.2021.103303] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]  Open
3
Raril C, Manjunatha JG. Fabrication of novel polymer-modified graphene-based electrochemical sensor for the determination of mercury and lead ions in water and biological samples. J Anal Sci Technol 2020. [DOI: 10.1186/s40543-019-0194-0] [Citation(s) in RCA: 36] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]  Open
4
Villis PCM, Filho JCS, Gomes WC, de Miranda RDCM, Nunes GS, Pissetti FL, Gushikem Y, Lucho AMS. Diethylenetriamine ion-imprinted silica gel for copper determination in tap water. J APPL ELECTROCHEM 2018. [DOI: 10.1007/s10800-018-1206-2] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/16/2022]
5
Nur Abdul Aziz SF, Zawawi R, Alang Ahmad SA. An Electrochemical Sensing Platform for the Detection of Lead Ions Based on Dicarboxyl-Calix[4]arene. ELECTROANAL 2018. [DOI: 10.1002/elan.201700736] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
6
Zinoubi K, Majdoub H, Barhoumi H, Boufi S, Jaffrezic-Renault N. Determination of trace heavy metal ions by anodic stripping voltammetry using nanofibrillated cellulose modified electrode. J Electroanal Chem (Lausanne) 2017. [DOI: 10.1016/j.jelechem.2017.05.039] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
7
Zhang P, Wang Y, Zhang D, Liu C, Wang D, He S, Hu G, Tang X. Calixarene-functionalized graphene oxide composites fixed on glassy carbon electrodes for electrochemical detection. RSC Adv 2016. [DOI: 10.1039/c6ra19674h] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]  Open
8
Liao Y, Li Q, Yue Y, Shao S. Selective electrochemical determination of trace level copper using a salicylaldehyde azine/MWCNTs/Nafion modified pyrolytic graphite electrode by the anodic stripping voltammetric method. RSC Adv 2015. [DOI: 10.1039/c4ra12342e] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]  Open
9
A simple but highly sensitive and selective calixarene-based voltammetric sensor for serotonin. Electrochim Acta 2013. [DOI: 10.1016/j.electacta.2012.09.033] [Citation(s) in RCA: 50] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
10
Ashkenani H, Taher MA. Selective voltammetric determination of Cu(II) based on multiwalled carbon nanotube and nano-porous Cu-ion imprinted polymer. J Electroanal Chem (Lausanne) 2012. [DOI: 10.1016/j.jelechem.2012.08.010] [Citation(s) in RCA: 49] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
11
Mokhtari B, Pourabdollah K. Voltammetric Study of Nano-baskets of Calix[4]-1,3-crowns-5, -crowns-6 Complexes. Electrochim Acta 2012. [DOI: 10.1016/j.electacta.2012.05.028] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
12
Electrochemical investigation of nano-baskets of calix[4]-1,3-crowns-5,6 complexes. J INCL PHENOM MACRO 2012. [DOI: 10.1007/s10847-012-0210-0] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
13
References. Anal Chem 2012. [DOI: 10.1201/b11478-14] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
14
Zhihua W, Xiaole L, Jianming Y, Yaxin Q, Xiaoquan L. Copper(II) determination by using carbon paste electrode modified with molecularly imprinted polymer. Electrochim Acta 2011. [DOI: 10.1016/j.electacta.2011.10.034] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
15
Mokhtari B, Pourabdollah K. Investigation of ionizable nano-baskets of calix[4]-1,2-crown-3 by differential pulse voltammetry. J COORD CHEM 2011. [DOI: 10.1080/00958972.2011.636040] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/15/2022]
16
Langmuir–Blodgett film of tetraoxocalix[2]arene[2]triazine modified electrode for voltammetric determination of copper ion. J Solid State Electrochem 2011. [DOI: 10.1007/s10008-011-1359-y] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
17
Mokhtari B, Pourabdollah K, Dalali N. Molecule and ion recognition of nano-baskets of calixarenes since 2005. J COORD CHEM 2011. [DOI: 10.1080/00958972.2011.555538] [Citation(s) in RCA: 52] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
18
Analytical applications of calixarenes from 2005 up-to-date. J INCL PHENOM MACRO 2010. [DOI: 10.1007/s10847-010-9848-7] [Citation(s) in RCA: 100] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
19
Carbon paste electrodes in the new millennium. OPEN CHEM 2009. [DOI: 10.2478/s11532-009-0097-9] [Citation(s) in RCA: 98] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]  Open
20
Sliwa W, Girek T. Calixarene complexes with metal ions. J INCL PHENOM MACRO 2009. [DOI: 10.1007/s10847-009-9678-7] [Citation(s) in RCA: 68] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
21
Electrochemical sensors and biosensors based on heterogeneous carbon materials. MONATSHEFTE FUR CHEMIE 2009. [DOI: 10.1007/s00706-009-0131-9] [Citation(s) in RCA: 49] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
22
Şar E, Berber H, Aşçı B, Cankurtaran H. Determination of Some Heavy Metal Ions with a Carbon Paste Electrode Modified by Poly(glycidylmethacrylate‐methylmethacrylate‐divinylbenzene) Microspheres Functionalized by 2‐Aminothiazole. ELECTROANAL 2008. [DOI: 10.1002/elan.200804208] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
23
Pulse anodic stripping voltammetric determination of copper with an amoxicillin–nafion modified glassy carbon electrode. J APPL ELECTROCHEM 2008. [DOI: 10.1007/s10800-008-9621-4] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
24
Modified carbon-containing electrodes in stripping voltammetry of metals. J Solid State Electrochem 2008. [DOI: 10.1007/s10008-007-0472-4] [Citation(s) in RCA: 42] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
PrevPage 1 of 1 1Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA