1
|
Le HTN, Phan LMT, Cho S. Removal of Thiol-SAM on a Gold Surface for Re-Use of an Interdigitated Chain-Shaped Electrode. MATERIALS 2022; 15:ma15062218. [PMID: 35329670 PMCID: PMC8950519 DOI: 10.3390/ma15062218] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/15/2022] [Revised: 03/07/2022] [Accepted: 03/15/2022] [Indexed: 11/16/2022]
Abstract
The self-assembled monolayer (SAM) is the most common organic assembly utilized for the formation of the monolayers of alkane-thiolates on gold electrode, resulting in a wide range of applications for the modified SAM on gold in various research areas. This study examined the desorption of a SAM that was developed on the gold surface of an interdigitated chain-shaped electrode (the ICE, a unique electrode design, was fabricated by our group) with the goal of determining the most efficient strategy of SAM removal for the ICE to be re-used. A simple and proficient solution-based cleaning procedure was applied for the removal of a SAM on the gold surface of the ICE by using a sodium borohydride solution within short-term treatment, resulting in efficiency for the recovery of the originally electrochemical characteristic of ICE of 90.3%. The re-use of ICE after the removal process was confirmed by the successful re-deposition of a SAM onto the electrode surface, resulting in the high efficiency percentage of 90.1% for the reusability of ICE with the SAM modification. Electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) were used as tools to investigate the changes in the electrode interface at each stage of the SAM removal and the electrode recycling. X-ray photoelectron spectroscopy and Fourier-transform infrared spectroscopy were employed, being powerful spectrum techniques, for the characterization of the bonding structure and chemical state of the bare ICE and the modified ICE at each treatment step. Based on the comprehensive discussion of analytical chemistry from the obtained EIS and CV data in this study, we confirmed and proved the effectiveness of this promising method for the removal of a SAM from the ICE and the re-use of ICE in the field of material deposition, with the aims of saving money, improving experimental handling, and protecting the environment.
Collapse
Affiliation(s)
- Hien T. Ngoc Le
- Department of Electronic Engineering, Gachon University, Seongnam-si 13120, Korea;
| | - Le Minh Tu Phan
- School of Medicine and Pharmacy, The University of Danang, Danang 550000, Vietnam;
| | - Sungbo Cho
- Department of Electronic Engineering, Gachon University, Seongnam-si 13120, Korea;
- Department of Health Sciences and Technology, GAIHST, Gachon University, Incheon 21999, Korea
- Correspondence: ; Tel.: +82-(31)-750-5321
| |
Collapse
|
2
|
David M, Şerban A, Adrian Enache T, Florescu M. Electrochemical quantification of levothyroxine at disposable screen-printed electrodes. J Electroanal Chem (Lausanne) 2022. [DOI: 10.1016/j.jelechem.2022.116240] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
3
|
Hassanpour S, Behnam B, Baradaran B, Hashemzaei M, Oroojalian F, Mokhtarzadeh A, de la Guardia M. Carbon based nanomaterials for the detection of narrow therapeutic index pharmaceuticals. Talanta 2020; 221:121610. [PMID: 33076140 DOI: 10.1016/j.talanta.2020.121610] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2020] [Revised: 08/26/2020] [Accepted: 08/27/2020] [Indexed: 12/17/2022]
Abstract
Precise detection of important pharmaceuticals with narrow therapeutic index (NTI) is very critical as there is a small window between their effective dose and the doses at which the adverse reactions are very likely to appear. Regarding the fact that various pharmacokinetics will be plausible while considering pharmacogenetic factors and also differences between generic and brand name drugs, accurate detection of NTI will be more important. Current routine analytical techniques suffer from many drawbacks while using novel biosensors can bring up many advantages including fast detection, accuracy, low cost with simple and repeatable measurements. Recently the well-known carbon Nano-allotropes including carbon nanotubes and graphenes have been widely used for development of different Nano-biosensors for a diverse list of analytes because of their great physiochemical features such as high tensile strength, ultra-light weight, unique electronic construction, high thermo-chemical stability, and an appropriate capacity for electron transfer. Because of these exceptional properties, scientists have developed an immense interest in these nanomaterials. In this case, there are important reports to show the effective Nano-carbon based biosensors in the detection of NTI drugs and the present review will critically summarize the available data in this field.
Collapse
Affiliation(s)
- Soodabeh Hassanpour
- Department of Analytical Chemistry, Faculty of Science, Palacky University Olomouc, 17. Listopadu 12, 77146, Olomouc, Czech Republic
| | - Behzad Behnam
- Pharmaceutics Research Center, Institute of Neuropharmacology, Kerman University of Medical Sciences, Kerman, Iran
| | - Behzad Baradaran
- Immunology Research Center, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Mahmoud Hashemzaei
- Department of Pharmacodynamics and Toxicology, School of Pharmacy, Zabol University of Medical Sciences, Zabol, Iran
| | - Fatemeh Oroojalian
- Department of Advanced Sciences and Technologies, School of Medicine, North Khorasan University of Medical Sciences, Bojnurd, Iran
| | - Ahad Mokhtarzadeh
- Immunology Research Center, Tabriz University of Medical Sciences, Tabriz, Iran.
| | - Miguel de la Guardia
- Department of Analytical Chemistry, University of Valencia, Dr. Moliner 50, 46100, Burjassot, Valencia, Spain.
| |
Collapse
|
4
|
Muñoz J, Crivillers N, Ravoo BJ, Mas-Torrent M. Cyclodextrin-based superparamagnetic host vesicles as ultrasensitive nanobiocarriers for electrosensing. NANOSCALE 2020; 12:9884-9889. [PMID: 32347277 DOI: 10.1039/d0nr01702g] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
A carbohydrate-based nanohybrid of superparamagnetic nanoparticles embedded in unilamellar bilayer vesicles of amphiphilic β-cyclodextrins (magnetic cyclodextrin vesicles, mCDVs) has been engineered as a novel magnetic biorecognition probe for electrosensing. As a proof-of-concept, the synergistic properties of these mCDVs on a magneto nanocomposite carbon-paste electrode (mNC-CPE) have been used for the picomolar determination of thyroxine (T4) as a model analyte (taking advantage of the host-guest chemistry of β-cyclodextrin and T4), resulting in the most sensitive electrochemical T4 system reported in the literature. Accordingly, a first demonstration of mCDVs as alternative water-soluble magnetic nanobiocarriers has been devised foreseeing their successful use as alternative electrochemical biosensing platforms for the supramolecular trace determination of alternative targets.
Collapse
Affiliation(s)
- Jose Muñoz
- Institut de Ciència de Materials de Barcelona (ICMAB-CSIC), and CIBER-BBN, Campus de la UAB, 08193 Bellaterra (Cerdanyola del Vallès), Spain.
| | - Núria Crivillers
- Institut de Ciència de Materials de Barcelona (ICMAB-CSIC), and CIBER-BBN, Campus de la UAB, 08193 Bellaterra (Cerdanyola del Vallès), Spain.
| | - Bart Jan Ravoo
- Organic Chemistry Institute and Center for Soft Nanoscience (SoN), Westfälische Wilhelms-Universität Münster, Correnstr. 40, 48149 Münster, Germany.
| | - Marta Mas-Torrent
- Institut de Ciència de Materials de Barcelona (ICMAB-CSIC), and CIBER-BBN, Campus de la UAB, 08193 Bellaterra (Cerdanyola del Vallès), Spain.
| |
Collapse
|
5
|
Brycht M, Konecka K, Sipa K, Skrzypek S, Mirčeski V. Electroanalysis of the Anthelmintic Drug Bithionol at Edge Plane Pyrolytic Graphite Electrode. ELECTROANAL 2019. [DOI: 10.1002/elan.201900322] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Affiliation(s)
- Mariola Brycht
- University of Lodz, Faculty of ChemistryDepartment of Inorganic and Analytical Chemistry Tamka 12 91-403 Lodz Poland
- Charles University, Faculty of Science, Department of Analytical ChemistryUNESCO Laboratory of Environmental Electrochemistry Albertov 6 CZ-12843 Prague 2 Czech Republic
| | - Kinga Konecka
- University of Lodz, Faculty of ChemistryDepartment of Inorganic and Analytical Chemistry Tamka 12 91-403 Lodz Poland
| | - Karolina Sipa
- University of Lodz, Faculty of ChemistryDepartment of Inorganic and Analytical Chemistry Tamka 12 91-403 Lodz Poland
| | - Sławomira Skrzypek
- University of Lodz, Faculty of ChemistryDepartment of Inorganic and Analytical Chemistry Tamka 12 91-403 Lodz Poland
| | - Valentin Mirčeski
- University of Lodz, Faculty of ChemistryDepartment of Inorganic and Analytical Chemistry Tamka 12 91-403 Lodz Poland
- Ss. Cyril and Methodius University, Faculty of Natural Sciences and MathematicsInstitute of Chemistry Arhimedova 5, P.O. Box 162 1001 Skopje R. Macedonia
| |
Collapse
|
6
|
Ghalkhani M, Bakirhan NK, Ozkan SA. Combination of Efficiency with Easiness, Speed, and Cheapness in Development of Sensitive Electrochemical Sensors. Crit Rev Anal Chem 2019; 50:538-553. [DOI: 10.1080/10408347.2019.1664281] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Affiliation(s)
- Masoumeh Ghalkhani
- Department of Chemistry, Faculty of Science, Shahid Rajaee Teacher Training University, Lavizan, Tehran, Iran
| | - Nurgul K. Bakirhan
- Department of Analytical Chemistry, Gulhane Faculty of Pharmacy, University of Health Science, Ankara, Turkey
| | - Sibel A. Ozkan
- Department of Analytical Chemistry, Faculty of Pharmacy, Ankara University, Ankara, Turkey
| |
Collapse
|
7
|
Lotfi S, Veisi H. Synthesis and characterization of novel nanocomposite (MWCNTs/CC-SH/Au) and its use as a modifier for construction of a sensitive sensor for determination of low concentration of levothyroxine in real samples. Chem Phys Lett 2019. [DOI: 10.1016/j.cplett.2018.12.029] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
8
|
Stefano JS, Dias AC, Arantes IVS, Costa BMC, Silva LAJ, Richter EM, Banks CE, Munoz RAA. Batch‐Injection Amperometric Analysis on Screen‐Printed Electrodes: Analytical System for High‐Throughput Determination of Pharmaceutical Molecules. ELECTROANAL 2018. [DOI: 10.1002/elan.201800725] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/15/2023]
Affiliation(s)
- Jéssica S. Stefano
- Instituto de QuímicaUniversidade Federal de Uberlândia Av. João Naves de Ávila, 2121 38408100 Uberlândia, MG Brazil
| | - Aline C. Dias
- Instituto de QuímicaUniversidade Federal de Uberlândia Av. João Naves de Ávila, 2121 38408100 Uberlândia, MG Brazil
| | - Iana V. S. Arantes
- Instituto de QuímicaUniversidade Federal de Uberlândia Av. João Naves de Ávila, 2121 38408100 Uberlândia, MG Brazil
| | - Brenda M. C. Costa
- Instituto de QuímicaUniversidade Federal de Uberlândia Av. João Naves de Ávila, 2121 38408100 Uberlândia, MG Brazil
| | - Luiz A. J. Silva
- Instituto de QuímicaUniversidade Federal de Uberlândia Av. João Naves de Ávila, 2121 38408100 Uberlândia, MG Brazil
| | - Eduardo M. Richter
- Instituto de QuímicaUniversidade Federal de Uberlândia Av. João Naves de Ávila, 2121 38408100 Uberlândia, MG Brazil
| | - Craig E. Banks
- Faculty of Science and EngineeringManchester Metropolitan University ce Manchester M1 5GD UK
| | - Rodrigo A. A. Munoz
- Instituto de QuímicaUniversidade Federal de Uberlândia Av. João Naves de Ávila, 2121 38408100 Uberlândia, MG Brazil
| |
Collapse
|
9
|
Ruiz-Vargas A, Mohd Rosli R, Ivorra A, Arkwright JW. Impedance spectroscopy measurements as a tool for distinguishing different luminal content during bolus transit studies. Neurogastroenterol Motil 2018; 30:e13274. [PMID: 29316025 DOI: 10.1111/nmo.13274] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/08/2017] [Accepted: 12/04/2017] [Indexed: 01/20/2023]
Abstract
BACKGROUND Intraluminal electrical impedance is a well-known diagnostic tool used to study bolus movement in the human esophagus. However, it is use in the human colon it is hindered by the fact that the content cannot be controlled and may include liquid, gas, solid, or a mixture of these at any one time. This article investigates the use of complex impedance spectroscopy to study different luminal content (liquid and gas). METHODS An excised section of guinea pig proximal colon was placed in an organ bath with Krebs solution at 37°C and a custom built bioimpedance catheter was placed in the lumen. Liquid (Krebs) and gas (air) content was pumped through the lumen and the intraluminal impedance was measured at five different frequencies (1, 5.6, 31.6, 177.18 kHz and 1 MHz) at 10 samples per second. A numerical model was created to model the passage of bolus with different content and compared to the experimental data. KEY RESULTS Differences in mean impedance magnitude and phase angle were found (from 1 to 177.18 kHz) for different contents. The numerical results qualitatively agreed with those in the experimental study. Conductivities of bolus had an effect on detecting its passage. CONCLUSIONS & INFERENCES Complex impedance spectroscopy can distinguish between different luminal content within a range of measuring frequencies. The numerical model showed the importance of bolus conductivities for bolus transit studies in those where the bolus is controlled.
Collapse
Affiliation(s)
- A Ruiz-Vargas
- The Medical Device Research Institute, College of Science and Engineering, Flinders University, Adelaide, Australia
| | - R Mohd Rosli
- Department of Gastroenterology and Surgery, Flinders Medical Centre, Adelaide, Australia
| | - A Ivorra
- Department of Information and Communication Technologies, Universitat Pompeu Fabra, Barcelona, Spain.,Serra Húnter Programme, Universitat Pompeu Fabra, Barcelona, Spain
| | - J W Arkwright
- The Medical Device Research Institute, College of Science and Engineering, Flinders University, Adelaide, Australia
| |
Collapse
|
10
|
Basmaz G, Öztürk N. Determination of Curcumin in Turmeric Sample Using Edge Plane Pyrolytic Graphite Electrode. ACTA ACUST UNITED AC 2017. [DOI: 10.18466/cbayarfbe.339339] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
11
|
Muñoz J, Riba-Moliner M, Brennan LJ, Gun’ko YK, Céspedes F, González-Campo A, Baeza M. Amperometric thyroxine sensor using a nanocomposite based on graphene modified with gold nanoparticles carrying a thiolated β-cyclodextrin. Mikrochim Acta 2016. [DOI: 10.1007/s00604-016-1783-x] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
12
|
Das A, Sangaranarayanan MV. Electroanalytical Sensor Based on Unmodified Screen‐Printed Carbon Electrode for the Determination of Levo‐Thyroxine. ELECTROANAL 2014. [DOI: 10.1002/elan.201400395] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Affiliation(s)
- Ashis Das
- Department of Chemistry, Indian Institute of Technology, Madras, Chennai‐600036, India
| | | |
Collapse
|
13
|
Gonçalves LM, Moreira MM, Azevedo CF, Valente IM, Sousa JC, Scanlan TS, Compton RG, Rodrigues JA. Proof of Concept of the Electrochemical Sensing of 3-Iodothyronamine (T1AM) and Thyronamine (T0AM). ChemElectroChem 2014. [DOI: 10.1002/celc.201402165] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|