1
|
Hydroxyapatite/L-Lysine Composite Coating as Glassy Carbon Electrode Modifier for the Analysis and Detection of Nile Blue A. MATERIALS 2022; 15:ma15124262. [PMID: 35744321 PMCID: PMC9230729 DOI: 10.3390/ma15124262] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/14/2022] [Revised: 06/09/2022] [Accepted: 06/13/2022] [Indexed: 12/13/2022]
Abstract
An amperometric sensor was developed by depositing a film coating of hydroxyapatite (HA)/L-lysine (Lys) composite material on a glassy carbon electrode (GCE). It was applied for the detection of Nile blue A (NBA). Hydroxyapatite was obtained from snail shells and its structural properties before and after its combination with Lys were characterized using X-ray diffraction (XRD), Fourier-transform infrared (FTIR) spectroscopy, scanning electron microscopy (SEM), and Brunauer-Emmett-Teller (BET) surface area analyses. The coupling of Lys to HA was attributed to favorable interaction between negatively charged -COO- groups of Lys and divalent ions Ca2+ of HA. Electrochemical investigations pointed out the improvement in sensitivity of the GCE/Lys/HA sensor towards the detection of NBA in solution. The dependence of the peak current and potential on the pH, scan rate, and NBA concentration was also investigated. Under optimal conditions, the GCE/Lys/HA sensor showed a good reproducibility, selectivity, and a NBA low detection limit of 5.07 × 10-8 mol L-1. The developed HA/Lys-modified electrode was successfully applied for the detection of NBA in various water samples.
Collapse
|
2
|
Wang ZZ, Wu PF, Yue HY, Gao X, Ma YY, Ma YY, Guo XR, Zhang HP. Electrochemical Determination of Levodopa Using Zinc Sulfide Nanospheres-Reduced Graphene Oxide. JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY 2021; 21:5666-5672. [PMID: 33980378 DOI: 10.1166/jnn.2021.19486] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Zinc sulfide nanospheres (ZnS NSs) were prepared by hydrothermal synthesis and graphene oxide (GO) was prepared by the Hummer's method. ZnS NSs-rGO/ITO electrode was synthesized by heat treatment at a certain temperature, which was used for the detailed electrochemical determination of levodopa (LD). Finally, they were annealed to form the ZnS NSs-rGO/ITO electrode for detecting levodopa (LD). The results reveal that the ZnS NSs with the diameter of ~1 μm are covered by rGO. The ZnS NSs-rGO/ITO electrode has a good sensitivity of 1.43 μA μM -1 for the determination of LD in the concentration range of 1-40 μM. Moreover, it also shows a good selectivity, reproducibility and stability. In order to verify the practicability, we also use the electrode to detect LD in human serum. The detection results also prove that the electrode can be used in real life.
Collapse
Affiliation(s)
| | - P F Wu
- School of Materials Science and Engineering, Harbin University of Science and Technology, Harbin 150040, People's Republic of China
| | - H Y Yue
- School of Materials Science and Engineering, Harbin University of Science and Technology, Harbin 150040, People's Republic of China
| | - X Gao
- School of Materials Science and Engineering, Harbin University of Science and Technology, Harbin 150040, People's Republic of China
| | - Y Y Ma
- School of Materials Science and Engineering, Harbin University of Science and Technology, Harbin 150040, People's Republic of China
| | - Y Y Ma
- School of Materials Science and Engineering, Harbin University of Science and Technology, Harbin 150040, People's Republic of China
| | - X R Guo
- School of Materials Science and Engineering, Harbin University of Science and Technology, Harbin 150040, People's Republic of China
| | - H P Zhang
- School of Materials Science and Engineering, Harbin University of Science and Technology, Harbin 150040, People's Republic of China
| |
Collapse
|
3
|
Voltammetric Determination of Levodopa Using Mesoporous Carbon-Modified Screen-Printed Carbon Sensors. SENSORS 2021; 21:s21186301. [PMID: 34577507 PMCID: PMC8471602 DOI: 10.3390/s21186301] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/02/2021] [Revised: 09/16/2021] [Accepted: 09/17/2021] [Indexed: 12/11/2022]
Abstract
Levodopa is a precursor of dopamine, having important beneficial effects in the treatment of Parkinson’s disease. In this study, levodopa was accurately detected by means of cyclic voltammetry using carbon-based (C-SPCE), mesoporous carbon (MC-SPCE) and ordered mesoporous carbon (OMC-SPCE)-modified screen-printed sensors. Screen-printed carbon sensors were initially used for the electrochemical detection of levodopa in a 10−3 M solution at pH 7.0. The mesoporous carbon with an organized structure led to better electroanalysis results and to lower detection and quantification limits of the OMC-SPCE sensor as compared to the other two studied sensors. The range of linearity obtained and the low values of the detection (0.290 µM) and quantification (0.966 µM) limit demonstrate the high sensitivity and accuracy of the method for the determination of levodopa in real samples. Therefore, levodopa was detected by means of OMC-SPCE in three dietary supplements produced by different manufacturers and having various concentrations of the active compound, levodopa. The results obtained by cyclic voltammetry were compared with those obtained by using the FTIR method and no significant differences were observed. OMC-SPCE proved to be stable, and the electrochemical responses did not vary by more than 3% in repeated immersions in a solution with the same concentration of levodopa. In addition, the interfering compounds did not significantly influence the peaks related to the presence of levodopa in the solution to be analyzed.
Collapse
|
4
|
Ghani SM, Rezaei B, Jamei HR, Ensafi AA. Novel synthesis of a dual fluorimetric sensor for the simultaneous analysis of levodopa and pyridoxine. Anal Bioanal Chem 2020; 413:377-387. [PMID: 33106947 DOI: 10.1007/s00216-020-03005-9] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2020] [Revised: 09/29/2020] [Accepted: 10/12/2020] [Indexed: 10/23/2022]
Abstract
Herein, a fluorimetric sensor was fabricated based on molecularly imprinted polymers (MIPs) with two types of carbon dots as fluorophores. The MIPs produced had similar excitation wavelengths (400 nm) and different emission wavelengths (445 and 545 nm). They were used for the simultaneous analysis of levodopa and pyridoxine. First, two types of carbon dots, i.e. nitrogen-doped carbon dots (NCDs) with a quantum yield of 43%, and carbon dots from o-phenylenediamine (O-CDs) with a quantum yield of 17%, were prepared using the hydrothermal method. Their surfaces were then covered with MIPs through the reverse microemulsion method. Finally, a mixture of powdered NCD@MIP and O-CD@MIP nanocomposites was used for the simultaneous fluorescence measurement of levodopa and pyridoxine. Under optimal conditions using response surface methodology and Design-Expert software, a linear dynamic range of 38 to 369 nM and 53 to 457 nM, and detection limits of 13 nM and 25 nM were obtained for levodopa and pyridoxine, respectively. The capability of the proposed fluorimetric sensor was investigated in human blood serum and urine samples. Graphical Abstract Schematic representation of nitrogen-doped carbon dots (NCDs), carbon dots from o-phenylenediamine (O-CDs), NCDs coated with imprinted polymers (NCD@MIPs), and O-CDs coated with imprinted polymers (O-CD@MIPs) in the presence and absence of levodopa and pyridoxine.
Collapse
Affiliation(s)
- Seyed Mohammad Ghani
- Department of Chemistry, Isfahan University of Technology, Emam Boulevard, Isfahan, 84156-83111, Iran
| | - Behzad Rezaei
- Department of Chemistry, Isfahan University of Technology, Emam Boulevard, Isfahan, 84156-83111, Iran.
| | - Hamid Reza Jamei
- Department of Chemistry, Isfahan University of Technology, Emam Boulevard, Isfahan, 84156-83111, Iran
| | - Ali Asghar Ensafi
- Department of Chemistry, Isfahan University of Technology, Emam Boulevard, Isfahan, 84156-83111, Iran
| |
Collapse
|
5
|
Preparation of Dawson heteropolyacid-embedded silver nanoparticles/graphene oxide nanocomposite thin film used to modify pencil graphite electrode as a sensor for trace electrochemical sensing of levodopa. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2020; 117:111287. [PMID: 32919648 DOI: 10.1016/j.msec.2020.111287] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/18/2020] [Revised: 07/09/2020] [Accepted: 07/17/2020] [Indexed: 12/20/2022]
Abstract
Measurement of levodopa (LD) as the most efficient treatment accessible for controlling the symptoms of Parkinson's disease was investigated. The electrocatalytic measurement of LD was performed at the surface of pencil graphite electrode (PGE) modified with graphene oxide (GO) and silver nanoparticle@Dawson heteropolyacid (AgNPs@DHPA). For this purpose, GO and the intermediate (AgNPs@DHPA) were first synthesized using a simple, cost-effective and straightforward method. The synthetic compounds, morphology, and surface characteristics of the modified sensor were evaluated. The results demonstrated that AgNPs@DHPA well-dispersed on the GO/PGE surface with a mean size of 6.27 nm and thickness of 42 nm. The electrochemical behavior of the modified PGE was also investigated. The heterogeneous charge transfer rate constant (ks) and transfer coefficient (α) for the electron transfer between AgNPs@DHPA/GO and PGE were obtained as 16.44 s-1 and 0.59, respectively. Also, the diffusion coefficient of LD for AgNPs@DHPA/GO/PGE thin film was calculated using chronoamperometric experiments (D = 9.05 × 10-6 cm2 s-1). Optimal parameters were obtained to access the best response for the measurement of LD. The results revealed that the modified PGE was able to measure the trace amounts of LD in phosphate buffer solution (pH = 6.0) in the concentration ranges from 3.0 × 10-9 to 1.0 × 10-7 M and 1.0 × 10-7 to 1.0 × 10-5 M. The calculated limit of detection was obtained 7.6 × 10-10 M which was much better than the previously reported electrochemical sensors. The modified electrode was used to measure LD in tablet, blood serum and urine.
Collapse
|
6
|
Ağın F, Öztürk G, Kul D. Voltammetric Analysis of Ephedrine in Pharmaceutical Dosage Forms and Urine Using poly(Nile Blue A) Modified Glassy Carbon Electrode. Comb Chem High Throughput Screen 2020; 24:366-375. [PMID: 32718283 DOI: 10.2174/1386207323666200727100231] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2020] [Revised: 05/21/2020] [Accepted: 06/12/2020] [Indexed: 11/22/2022]
Abstract
OBJECTIVE The electrochemical analysis of ephedrine which is a sympathometric drug has been studied using poly(Nile blue A) modified glassy carbon electrodes, cyclic voltammetry, differential pulse voltammetry and square wave voltammetry. METHODS The modified electrodes were prepared by potential cycling electropolymerization of Nile blue A in 0.1 M phosphate buffer solution at pH 6.0. The redox behavior of ephedrine was investigated in different buffer solutions at pH values between 5.5 and 9.0. RESULTS Scan rate studies showed that the electron transfer reaction of ephedrine was diffusion controlled. A linear response was obtained between the peak current and the ephedrine concentration in the range of 0.6 to 100 μM with a limit of detection of 2.91×10-3 μM for differential pulse voltammetry in Britton-Robinson buffer solution at pH 9.0. The linearity range of ephedrine in human urine was between 1.0 and 100 μM with a detection limit of 8.16 nM. CONCLUSION The recovery studies in both pharmaceutical dosage forms and urine showed that the proposed method ensured good selectivity, precision and accuracy without any interference from inactive excipients.
Collapse
Affiliation(s)
- Fatma Ağın
- Department of Analytical Chemistry, Faculty of Pharmacy, Karadeniz Technical University, Ortahisar, 61080, Trabzon, Turkey
| | - Gökçe Öztürk
- Department of Analytical Chemistry, Faculty of Pharmacy, Karadeniz Technical University, Ortahisar, 61080, Trabzon, Turkey
| | - Dilek Kul
- Department of Analytical Chemistry, Faculty of Pharmacy, Karadeniz Technical University, Ortahisar, 61080, Trabzon, Turkey
| |
Collapse
|
7
|
Işık H, Öztürk G, Ağın F, Kul D. Electroanalytical Analysis of Guaifenesin on Poly(Acridine Orange) Modified Glassy Carbon Electrode and its Determination in Pharmaceuticals and Serum Samples. Comb Chem High Throughput Screen 2020; 24:376-385. [PMID: 32646355 DOI: 10.2174/1386207323666200709170450] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2020] [Revised: 04/13/2020] [Accepted: 04/29/2020] [Indexed: 11/22/2022]
Abstract
BACKGROUND Electroanalytical methods are very functional to detect drugs in pharmaceuticals (tablets, syrups, suppositories, creams, and ointments) and biological samples. OBJECTIVE This study is aimed to make selective, sensitive, simple, fast, and low cost electrochemical analysis of expectorant drug guaifenesin in pharmaceuticals and serum samples. METHODS Differential pulse adsorptive stripping voltammetric method for determination of guaifenesin on a poly(acridine orange) modified glassy carbon electrode has been developed. Glassy carbon electrode was modified with electropolymerization of the acridine orange monomer for the sensitive determination of guaifenesin. Guaifenesin provided highly reproducible and welldefined irreversible oxidation peaks at +1.125 V and +1.128 V (vs. Ag/AgCl) in the selected supporting electrolyte and human serum samples, respectively. RESULTS Under optimized conditions, linear response of peak current on the concentration of guaifenesin has been obtained in the ranges of 2.00×10-7 to 1.00×10-4 M in Britton Robinson buffer solution at pH 7.0 and 4.00×10-7 to 1.00×10-4 M in serum samples. The precision of the method was detected by intraday and inter-day repeatability studies in the supporting electrolyte and serum samples media. CONCLUSION The analytical applicability of the proposed method exhibited satisfying determination results for guaifenesin from pharmaceutical dosage forms (syrup) and human serum samples without any pre-separation procedures.
Collapse
Affiliation(s)
- Hasan Işık
- Department of Analytical Chemistry, Faculty of Pharmacy, Karadeniz Teknik University, Trabzon, Turkey
| | - Gökçe Öztürk
- Department of Analytical Chemistry, Faculty of Pharmacy, Karadeniz Teknik University, Trabzon, Turkey
| | - Fatma Ağın
- Department of Analytical Chemistry, Faculty of Pharmacy, Karadeniz Teknik University, Trabzon, Turkey
| | - Dilek Kul
- Department of Analytical Chemistry, Faculty of Pharmacy, Karadeniz Teknik University, Trabzon, Turkey
| |
Collapse
|
8
|
|
9
|
Mohamed D, Hegazy MA, Elshahed MS, Toubar SS, Helmy MI. Novel contribution to the simultaneous monitoring of pramipexole dihydrochloride monohydrate and levodopa as co-administered drugs in human plasma utilizing UPLC-MS/MS. EUROPEAN JOURNAL OF MASS SPECTROMETRY (CHICHESTER, ENGLAND) 2018; 24:397-407. [PMID: 30012017 DOI: 10.1177/1469066718788800] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
An efficient, selective, sensitive, and rapid ultra-performance liquid chromatography tandem mass spectrometry method was established and validated for the quantification of pramipexole dihydrochloride monohydrate and levodopa simultaneously in human plasma with the aid of diphenhydramine as an internal standard. A simple protein precipitation technique with HPLC grade acetonitrile was efficiently utilized for the cleanup of plasma. The analysis was performed using a Hypersil gold 50 mm × 2.1 mm (1.9 µm) column and a mobile phase of 0.2% formic acid and methanol (90: 10 v/v). The triple-quadrupole mass spectrometer equipped with an electrospray source operated in the positive mode was set up in the selective reaction monitoring mode (SRM) to detect the ion transitions m/z 212.15 →153.01, m/z 198.10→ 135.16, and m/z 255.75 → 166.16 for pramipexole dihydrochloride monohydrate, levodopa, and diphenhydramine, respectively. The method was thoroughly validated according to FDA guidelines and proved to be linear, accurate, and precise over the range 100-4000 pg/mL for pramipexole dihydrochloride monohydrate and 60-4000 ng/mL for levodopa. The proposed method was effectively applied for monitoring both drugs in plasma samples of healthy volunteers.
Collapse
Affiliation(s)
- Dalia Mohamed
- 1 Analytical Chemistry Department, Faculty of Pharmacy, Helwan University, Cairo, Egypt
- 2 Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, October University for Modern Sciences and Arts, 6 October City, Egypt
| | - Maha A Hegazy
- 3 Analytical Chemistry Department, Faculty of Pharmacy, Cairo University, Cairo, Egypt
| | - Mona S Elshahed
- 1 Analytical Chemistry Department, Faculty of Pharmacy, Helwan University, Cairo, Egypt
| | - Safaa S Toubar
- 1 Analytical Chemistry Department, Faculty of Pharmacy, Helwan University, Cairo, Egypt
| | - Marwa I Helmy
- 1 Analytical Chemistry Department, Faculty of Pharmacy, Helwan University, Cairo, Egypt
| |
Collapse
|
10
|
Baião V, Tomé LI, Brett CM. Iron Oxide Nanoparticle and Multiwalled Carbon Nanotube Modified Glassy Carbon Electrodes. Application to Levodopa Detection. ELECTROANAL 2018. [DOI: 10.1002/elan.201700854] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Affiliation(s)
- Vanessa Baião
- Department of Chemistry, Faculty of Sciences and Technology; University of Coimbra; 3004-535 Coimbra Portugal
| | - Luciana I.N. Tomé
- Department of Chemistry, Faculty of Sciences and Technology; University of Coimbra; 3004-535 Coimbra Portugal
| | - Christopher M.A. Brett
- Department of Chemistry, Faculty of Sciences and Technology; University of Coimbra; 3004-535 Coimbra Portugal
| |
Collapse
|
11
|
Gao X, Yue H, Song S, Huang S, Li B, Lin X, Guo E, Wang B, Guan E, Zhang H, Wu P. 3-Dimensional hollow graphene balls for voltammetric sensing of levodopa in the presence of uric acid. Mikrochim Acta 2018; 185:91. [PMID: 29594616 DOI: 10.1007/s00604-017-2644-y] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2017] [Accepted: 12/28/2017] [Indexed: 01/24/2023]
Abstract
The development of novel nanomaterials brings new opportunity and challenge for high sensing detection of biomolecules. The authors describe the preparation of 3-dimentional hollow graphene balls (3D HGBs) using nickel nanoparticles (Ni-NPs) as the template. The Ni-NPs were synthesized by chemical reduction of nickel chloride and then graphene was coated onto their surface via carburization and carbonization. After etching Ni-NPs, 3D HGBs with few layers and a typical size of 100 nm were obtained. They were sprayed onto indium tin oxide glass to obtain a working electrode for electrochemical determination of levodopa in the presence of uric acid. Due to the unique hollow porous structure of the 3D HGBs, the electrode exhibits a sensitivity of 0.69 μA·μM-1·cm-2 and a 1 μM limit of detection. It is selective, reproducible and stable. It was applied to the determination of levodopa in spiked human plasma samples and it is of potential use in clinical research. Graphical abstract Schematic presentation of the preparation of 3-dimensional hollow graphene balls (HGBs) by using nickel nanoparticles as a template that can be removed by etching. The HGBs were sprayed onto indium tin oxide (ITO) glass to obtain a working electrode that has a sensitivity of 0.69 μA⋅μM-1·cm-2 and a 1 μM limit of detection for the determination of levodopa.
Collapse
Affiliation(s)
- Xin Gao
- School of Materials Science and Engineering, Harbin University of Science and Technology, Harbin, 150040, People's Republic of China
| | - Hongyan Yue
- School of Materials Science and Engineering, Harbin University of Science and Technology, Harbin, 150040, People's Republic of China.
| | - Shanshan Song
- School of Materials Science and Engineering, Harbin University of Science and Technology, Harbin, 150040, People's Republic of China
| | - Shuo Huang
- School of Materials Science and Engineering, Harbin University of Science and Technology, Harbin, 150040, People's Republic of China.,Department of Neurology, The First Affiliated Hospital of Harbin Medical University, Harbin, 150001, People's Republic of China
| | - Bing Li
- Department of Materials Science and Engineering, Korea Advanced Institute of Science and Technology, Daejeon, 34141, Republic of Korea
| | - Xuanyu Lin
- School of Materials Science and Engineering, Harbin University of Science and Technology, Harbin, 150040, People's Republic of China
| | - Erjun Guo
- School of Materials Science and Engineering, Harbin University of Science and Technology, Harbin, 150040, People's Republic of China
| | - Bao Wang
- School of Materials Science and Engineering, Harbin University of Science and Technology, Harbin, 150040, People's Republic of China
| | - Enhao Guan
- School of Materials Science and Engineering, Harbin University of Science and Technology, Harbin, 150040, People's Republic of China
| | - Hongjie Zhang
- School of Materials Science and Engineering, Harbin University of Science and Technology, Harbin, 150040, People's Republic of China
| | - Pengfei Wu
- School of Materials Science and Engineering, Harbin University of Science and Technology, Harbin, 150040, People's Republic of China
| |
Collapse
|
12
|
Palakollu VN, Thapliyal N, Chiwunze TE, Karpoormath R, Karunanidhi S, Cherukupalli S. Electrochemically reduced graphene oxide/Poly-Glycine composite modified electrode for sensitive determination of l-dopa. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2017; 77:394-404. [DOI: 10.1016/j.msec.2017.03.173] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/22/2016] [Revised: 03/18/2017] [Accepted: 03/21/2017] [Indexed: 11/15/2022]
|
13
|
Sheikh-Mohseni MA, Pirsa S. Nanostructured Conducting Polymer/Copper Oxide as a Modifier for Fabrication of L-DOPA and Uric Acid Electrochemical Sensor. ELECTROANAL 2016. [DOI: 10.1002/elan.201600089] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Affiliation(s)
| | - Sajad Pirsa
- Department of Food Science and Technology, Faculty of Agriculture; Urmia University; Urmia I.R. Iran
| |
Collapse
|
14
|
Chitravathi S, Munichandraiah N. Voltammetric determination of paracetamol, tramadol and caffeine using poly(Nile blue) modified glassy carbon electrode. J Electroanal Chem (Lausanne) 2016. [DOI: 10.1016/j.jelechem.2016.01.021] [Citation(s) in RCA: 76] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
|
15
|
Ağın F. Electrochemical Determination of Amoxicillin on a Poly(Acridine Orange) Modified Glassy Carbon Electrode. ANAL LETT 2015. [DOI: 10.1080/00032719.2015.1101602] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
|
16
|
Barsan MM, Ghica ME, Brett CMA. Electrochemical sensors and biosensors based on redox polymer/carbon nanotube modified electrodes: a review. Anal Chim Acta 2015; 881:1-23. [PMID: 26041516 DOI: 10.1016/j.aca.2015.02.059] [Citation(s) in RCA: 213] [Impact Index Per Article: 23.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2014] [Revised: 02/20/2015] [Accepted: 02/22/2015] [Indexed: 11/24/2022]
Abstract
The aim of this review is to present the contributions to the development of electrochemical sensors and biosensors based on polyphenazine or polytriphenylmethane redox polymers together with carbon nanotubes (CNT) during recent years. Phenazine polymers have been widely used in analytical applications due to their inherent charge transport properties and electrocatalytic effects. At the same time, since the first report on a CNT-based sensor, their application in the electroanalytical chemistry field has demonstrated that the unique structure and properties of CNT are ideal for the design of electrochemical (bio)sensors. We describe here that the specific combination of phenazine/triphenylmethane polymers with CNT leads to an improved performance of the resulting sensing devices, because of their complementary electrical, electrochemical and mechanical properties, and also due to synergistic effects. The preparation of polymer/CNT modified electrodes will be presented together with their electrochemical and surface characterization, with emphasis on the contribution of each component on the overall properties of the modified electrodes. Their importance in analytical chemistry is demonstrated by the numerous applications based on polymer/CNT-driven electrocatalytic effects, and their analytical performance as (bio) sensors is discussed.
Collapse
Affiliation(s)
- Madalina M Barsan
- Departamento de Química, Faculdade de Ciências e Tecnologia, Universidade de Coimbra, 3004-535 Coimbra, Portugal
| | - M Emilia Ghica
- Departamento de Química, Faculdade de Ciências e Tecnologia, Universidade de Coimbra, 3004-535 Coimbra, Portugal
| | - Christopher M A Brett
- Departamento de Química, Faculdade de Ciências e Tecnologia, Universidade de Coimbra, 3004-535 Coimbra, Portugal.
| |
Collapse
|
17
|
Li J, Feng H, Jiang J, Feng Y, Xu Z, Qian D. One-pot in situ synthesis of a CoFe2O4nanoparticle-reduced graphene oxide nanocomposite with high performance for levodopa sensing. RSC Adv 2015. [DOI: 10.1039/c5ra15379d] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022] Open
Abstract
We demonstrate that a new nanocomposite of CoFe2O4-reduced graphene oxide can be used as an enhanced electrochemical sensing platform for levodopa.
Collapse
Affiliation(s)
- Junhua Li
- College of Chemistry and Chemical Engineering
- Central South University
- Changsha 410083
- PR China
- College of Chemistry and Materials Science
| | - Haibo Feng
- College of Chemistry and Chemical Engineering
- Central South University
- Changsha 410083
- PR China
| | - Jianbo Jiang
- College of Chemistry and Chemical Engineering
- Central South University
- Changsha 410083
- PR China
| | - Yonglan Feng
- College of Chemistry and Materials Science
- Hengyang Normal University
- Hengyang 421008
- PR China
| | - Zhifeng Xu
- College of Chemistry and Materials Science
- Hengyang Normal University
- Hengyang 421008
- PR China
| | - Dong Qian
- College of Chemistry and Chemical Engineering
- Central South University
- Changsha 410083
- PR China
- State Key Laboratory of Powder Metallurgy
| |
Collapse
|
18
|
Hatefi-Mehrjardi A, Ghaemi N, Karimi MA, Ghasemi M, Islami-Ramchahi S. Poly-(Alizarin Red S)-Modified Glassy Carbon Electrode for Simultaneous Electrochemical Determination of Levodopa, Homovanillic Acid and Ascorbic Acid. ELECTROANAL 2014. [DOI: 10.1002/elan.201400302] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
|