1
|
Kosker FB, Aydin O, Icoz K. Simple Staining of Cells on a Chip. BIOSENSORS 2022; 12:1013. [PMID: 36421132 PMCID: PMC9688635 DOI: 10.3390/bios12111013] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/10/2022] [Revised: 11/10/2022] [Accepted: 11/11/2022] [Indexed: 06/16/2023]
Abstract
Simple staining of cells is a widely used method in basic medical diagnostics, education, and research laboratories. The stains are low-cost, but the extensive consumption results in excessive toxic waste generation. Thus, to decrease the amount of toxic waste resulting from the cell staining procedure is a need. In this study, we developed a magnetically driven and compartmentalized passive microfluidic chip to perform simple staining of human eukaryotic cells, K562 cells, and lymphocyte cells derived from patients. We demonstrated simple staining on cells with trypan blue, methylene blue, crystal violet, and safranin for high, medium, and low cell densities. The stained cells were imaged using a bright field optical microscope and a cell phone to count cells on the focal plane. The staining improved the color signal of the cell by 25-135-pixel intensity changes for the microscopic images. The validity of the protocol was determined using Jurkat and MDA-MB-231 cell lines as negative controls. In order to demonstrate the practicality of the system, lymphocyte cells derived from human blood samples were stained with trypan blue. The color intensity changes in the first and last compartments were analyzed to evaluate the performance of the chip. The developed method is ultra-low cost, significantly reduces the waste generated, and can be integrated with mobile imaging devices in terms of portability. By combining microfabrication technology with cell staining, this study reported a novel contribution to the field of microfluidic biosensors. In the future, we expect to demonstrate the detection of pathogens using this method.
Collapse
Affiliation(s)
- Fatma Betul Kosker
- Department of Biomedical Engineering, Erciyes University, 38039 Kayseri, Türkiye
- Nanothera Lab, Drug Application and Research Center (ERFARMA), Erciyes University, 38039 Kayseri, Türkiye
- Department of Biomedical Engineering, Pamukkale University, 20160 Denizli, Türkiye
| | - Omer Aydin
- Department of Biomedical Engineering, Erciyes University, 38039 Kayseri, Türkiye
- Nanothera Lab, Drug Application and Research Center (ERFARMA), Erciyes University, 38039 Kayseri, Türkiye
- Clinical Engineering Research and Implementation Center (ERKAM), Erciyes University, 38030 Kayseri, Türkiye
- Nanotechnology Research and Application Center (ERNAM), Erciyes University, 38039 Kayseri, Türkiye
| | - Kutay Icoz
- Department of Electrical and Electronics Engineering, Abdullah Gül University, 38080 Kayseri, Türkiye
| |
Collapse
|
2
|
FAROOQİ MF, İÇÖZ K. Magnetic Separation of Micro Beads and Cells on a Paper-Based Lateral Flow System. GAZI UNIVERSITY JOURNAL OF SCIENCE 2022. [DOI: 10.35378/gujs.1146050] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Paper based lateral flow systems are widely used biosensor platforms to detect biomolecules in a liquid sample. Proteins, bacteria, oligonucleotides, and nanoparticles were investigated in the literature. In this work we designed a magnetic platform including dual magnets and tested the flow of micron size immunomagnetic particles alone and when loaded with cells on two different types of papers. The wetting conditions of the paper and the applied external magnetic field are the two dominant factors affecting the particle and cell transport in paper. The images recorded with a cell phone, or with a bright field optical microscope were analyzed to measure the flow of particles and cells. The effect of wetting conditions and magnetic force were measured, and it was shown that in the worst case 90% of the introduced cells reached to the edge of the paper. The paper based magnetophoretic lateral flow systems can be used for cell assays.
Collapse
|
3
|
Soylu MÇ, Azgin ST. Sensitive Multi‐Detection of
Escherichia coli
by Quartz Crystal Microbalance with a Novel Surface Controllable Sensing Method in Liquid Organic Fertilizer Produced by Sewage Sludge. ChemistrySelect 2021. [DOI: 10.1002/slct.202102149] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Affiliation(s)
- Mehmet Çağrı Soylu
- Biological and Medical Diagnostic Sensors Laboratory (BioMeD Sensors Lab) Department of Biomedical Engineering Erciyes University Kayseri 38039 Turkey
| | - Sukru Taner Azgin
- Department of Environmental Engineering Erciyes University Kayseri 38039 Turkey
| |
Collapse
|
4
|
Soysaldı F, Soylu MÇ. The Effect of (3‐Mercaptopropyl)trimethoxysilane (MPS) Coating on the Genetic Detection Performance of Quartz Crystal Microbalance‐Dissipation (QCM‐D) Biosensor: Novel Intact Double‐Layered Surface Modification on QCM‐D. ChemistrySelect 2021. [DOI: 10.1002/slct.202100739] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Affiliation(s)
- Furkan Soysaldı
- Department of Electronic and Automation Vocational School Nevsehir Haci Bektas Veli University Nevsehir 50300 Turkey
| | - Mehmet Çağrı Soylu
- Biological & Medical Diagnostic (BioMeD) Sensors Laboratory Department of Biomedical Engineering Erciyes University Kayseri 38030 Turkey
| |
Collapse
|
5
|
Microfluidic Chip based direct triple antibody immunoassay for monitoring patient comparative response to leukemia treatment. Biomed Microdevices 2020; 22:48. [PMID: 32661698 DOI: 10.1007/s10544-020-00503-6] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
We report a time and cost-efficient microfluidic chip for screening the leukemia cells having three specific antigens. In this method, the target blast cells are double sorted with immunomagnetic beads and captured by the 3rd antibody immobilized on the gold surface in a microfluidic chip. The captured blast cells in the chip were imaged using a bright-field optical microscope and images were analyzed to quantify the cells. First sorting was performed with nano size immunomagnetic beads and followed by 2nd sorting where micron size immunomagnetic beads were used. The low-cost microfluidic platform is made of PMMA and glass including micro size gold pads. The developed microfluidic platform was optimized with cultured B type lymphoblast cells and tested with the samples of leukemia patients. The 8 bone marrow samples of 4 leukemia patients on the initial diagnosis and on the 15th day after the start of the chemotherapy treatment were tested both with the developed microfluidic platform and the flow cytometry. A 99% statistical agreement between the two methods shows that the microfluidic chip is able to monitor the decrease in the number of blast cells due to the chemotherapy. The experiments with the patient samples demonstrate that the developed system can perform relative measurements and have a potential to monitor the patient response to the applied therapy and to enable personalized dose adjustment.
Collapse
|
6
|
Chai C, Oh SW. Electrochemical impedimetric biosensors for food safety. Food Sci Biotechnol 2020; 29:879-887. [PMID: 32582450 PMCID: PMC7297935 DOI: 10.1007/s10068-020-00776-w] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2020] [Revised: 05/12/2020] [Accepted: 05/17/2020] [Indexed: 12/20/2022] Open
Abstract
Electrochemical impedimetric biosensors (EIBs) have a simple structure and can be used to rapidly and sensitively detect and measure hazards in food. EIBs detect and measure target molecules by transducing biochemical reactions on their surface to electrical signal outputs responding to a sinusoidal electrical signal input. Due to their structural simplicity and analytical sensitivity, EIBs are regarded as the most potent method of food hazard monitoring that can be implemented in the food supply chain. This paper discusses the theoretical background, structure, and construction of EIB and its applications in food safety.
Collapse
Affiliation(s)
- Changhoon Chai
- Department of Applied Animal Science, Kangwon National University, Chuncheon, 24341 Republic of Korea
| | - Se-Wook Oh
- Department of Food and Nutrition, Kookmin University, Seoul, 02707 Republic of Korea
| |
Collapse
|
7
|
Uslu F, Icoz K, Tasdemir K, Doğan RS, Yilmaz B. Image-analysis based readout method for biochip: Automated quantification of immunomagnetic beads, micropads and patient leukemia cell. Micron 2020; 133:102863. [DOI: 10.1016/j.micron.2020.102863] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2020] [Revised: 03/05/2020] [Accepted: 03/19/2020] [Indexed: 01/01/2023]
|
8
|
Cimafonte M, Fulgione A, Gaglione R, Papaianni M, Capparelli R, Arciello A, Bolletti Censi S, Borriello G, Velotta R, Della Ventura B. Screen Printed Based Impedimetric Immunosensor for Rapid Detection of Escherichia coli in Drinking Water. SENSORS 2020; 20:s20010274. [PMID: 31947810 PMCID: PMC6982893 DOI: 10.3390/s20010274] [Citation(s) in RCA: 32] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/29/2019] [Revised: 12/27/2019] [Accepted: 12/30/2019] [Indexed: 12/19/2022]
Abstract
The development of a simple and low cost electrochemical impedance immunosensor based on screen printed gold electrode for rapid detection of Escherichia coli in water is reported. The immunosensor is fabricated by immobilizing anti-E. coli antibodies onto a gold surface in a covalent way by the photochemical immobilization technique, a simple procedure able to bind antibodies upright onto gold surfaces. Impedance spectra are recorded in 0.01 M phosphate buffer solution (PBS) containing 10 mM Fe(CN)63−/Fe(CN)64− as redox probe. The Nyquist plots can be modelled with a modified Randles circuit, identifying the charge transfer resistance Rct as the relevant parameter after the immobilization of antibodies, the blocking with BSA and the binding of E. coli. The introduction of a standard amplification procedure leads to a significant enhancement of the impedance increase, which allows one to measure E. coli in drinking water with a limit of detection of 3 × 101 CFU mL−1 while preserving the rapidity of the method that requires only 1 h to provide a “yes/no” response. Additionally, by applying the Langmuir adsorption model, we are able to describe the change of Rct in terms of the “effective” electrode, which is modified by the detection of the analyte whose microscopic conducting properties can be quantified.
Collapse
Affiliation(s)
- Martina Cimafonte
- Department of Physics “Ettore Pancini”, University of Naples “Federico II”, Via Cinthia, 26, 80126 Naples, Italy; (M.C.); (R.V.)
| | - Andrea Fulgione
- Istituto Zooprofilattico Sperimentale del Mezzogiorno, Via Salute, 2, 80055 Portici Naples, Italy; (A.F.); (G.B.)
- Department of Agriculture, University of Naples “Federico II”, Via Università, 133, 80055 Portici Naples, Italy; (M.P.); (R.C.)
| | - Rosa Gaglione
- Department of Chemical Sciences, University of Naples “Federico II”, Via Cinthia, 26, 80126 Naples, Italy; (R.G.); (A.A.)
| | - Marina Papaianni
- Department of Agriculture, University of Naples “Federico II”, Via Università, 133, 80055 Portici Naples, Italy; (M.P.); (R.C.)
| | - Rosanna Capparelli
- Department of Agriculture, University of Naples “Federico II”, Via Università, 133, 80055 Portici Naples, Italy; (M.P.); (R.C.)
| | - Angela Arciello
- Department of Chemical Sciences, University of Naples “Federico II”, Via Cinthia, 26, 80126 Naples, Italy; (R.G.); (A.A.)
| | | | - Giorgia Borriello
- Istituto Zooprofilattico Sperimentale del Mezzogiorno, Via Salute, 2, 80055 Portici Naples, Italy; (A.F.); (G.B.)
| | - Raffaele Velotta
- Department of Physics “Ettore Pancini”, University of Naples “Federico II”, Via Cinthia, 26, 80126 Naples, Italy; (M.C.); (R.V.)
| | - Bartolomeo Della Ventura
- Department of Physics, Politecnico di Milano, Piazza Leonardo da Vinci, 32, 20133 Milano, Italy
- Correspondence:
| |
Collapse
|
9
|
İçöz K, Gerçek T, Murat A, Özcan S, Ünal E. Capturing B type acute lymphoblastic leukemia cells using two types of antibodies. Biotechnol Prog 2018; 35:e2737. [PMID: 30353996 DOI: 10.1002/btpr.2737] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2018] [Revised: 09/07/2018] [Accepted: 10/16/2018] [Indexed: 11/07/2022]
Abstract
One way to monitor minimal residual disease (MRD) is to screen cells for multiple surface markers using flow cytometry. In order to develop an alternative microfluidic based method, isolation of B type acute lymphoblastic cells using two types of antibodies should be investigated. The immunomagnetic beads coated with various antibodies are used to capture the B type acute lymphoblastic cells. Single beads, two types of beads and surface immobilized antibody were used to measure the capture efficiency. Both micro and nanosize immunomagnetic beads can be used to capture B type acute lymphoblastic cells with a minimum efficiency of 94% and maximum efficiency of 98%. Development of a microfluidic based biochip incorporating immunomagnetic beads and surface immobilized antibodies for monitoring MRD can be an alternative to current cost and time inefficient laboratory methods. © 2018 American Institute of Chemical Engineers Biotechnol. Prog., 35: e2737, 2019.
Collapse
Affiliation(s)
- Kutay İçöz
- BioMINDS (Bio Micro/Nano Devices and Sensors) Lab, Dept. of Electrical and Electronics Engineering, Abdullah Gül University, Kayseri, Turkey
- Bioengineering Dept., Abdullah Gül University, Kayseri, Turkey
| | - Tayyibe Gerçek
- BioMINDS (Bio Micro/Nano Devices and Sensors) Lab, Dept. of Electrical and Electronics Engineering, Abdullah Gül University, Kayseri, Turkey
- Bioengineering Dept., Abdullah Gül University, Kayseri, Turkey
| | - Ayşegül Murat
- Genome and Stem Cell Center (GENKOK), Erciyes University, Kayseri, Turkey
| | - Servet Özcan
- Biology Dept., Erciyes University, Kayseri, Turkey
- Genome and Stem Cell Center (GENKOK), Erciyes University, Kayseri, Turkey
| | - Ekrem Ünal
- Pediatric Oncology Dept., Erciyes University, Kayseri, Turkey
| |
Collapse
|