1
|
Kongkaew S, Janduang S, Srilikhit A, Kaewnu K, Thipwimonmas Y, Cotchim S, Torrarit K, Phua CH, Limbut W. Waste DVD polycarbonate substrate for screen-printed carbon electrode modified with PVP-stabilized AuNPs for continuous free chlorine detection. Talanta 2024; 277:126406. [PMID: 38901193 DOI: 10.1016/j.talanta.2024.126406] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2024] [Revised: 06/07/2024] [Accepted: 06/09/2024] [Indexed: 06/22/2024]
Abstract
An electrochemical free chlorine sensor was developed by modifying a lab-made screen-printed carbon electrode (SPCE) with gold nanoparticles synthesized with polyvinylpyrrolidone (AuNPs-PVP). The electrode was made by screen printing carbon ink on a waste digital versatile disc (SPC-wDVD). PVP was used to stabilize AuNPs. Scanning electron microscopy showed that AuNPs aggregated without the stabilizer. The electrochemical behavior of the SPC-wDVD was evaluated by comparison with commercial SPCEs from two companies. Electrochemical characterization involved cyclic voltammetry and electrochemical impedance spectroscopy. The detection of free chlorine in water samples was continuous, facilitated by a flow-injection system. In the best condition, the developed sensor exhibited linearity from 0.25 to 3.0 and 3.0 to 500 mg L-1. The limit of detection was 0.1 mg L-1. The stability of the sensor enabled the detection of free chlorine at least 475 times with an RSD of 3.2 %. The AuNPs-PVP/SPC-wDVD was able to detect free chlorine in drinking water, tap water and swimming pool water. The agreement between the results obtained with the proposed method and the standard spectrophotometric method confirmed the precision of the developed sensor.
Collapse
Affiliation(s)
- Supatinee Kongkaew
- Center of Excellence for Trace Analysis and Biosensor, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Center of Excellence for Innovation in Chemistry, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Division of Health and Applied Sciences, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand
| | - Santipap Janduang
- Center of Excellence for Trace Analysis and Biosensor, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Center of Excellence for Innovation in Chemistry, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Division of Physical Science, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand
| | - Angkana Srilikhit
- Center of Excellence for Trace Analysis and Biosensor, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Center of Excellence for Innovation in Chemistry, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Division of Physical Science, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand
| | - Krittapas Kaewnu
- Center of Excellence for Trace Analysis and Biosensor, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Division of Health and Applied Sciences, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand
| | - Yudtapum Thipwimonmas
- Center of Excellence for Trace Analysis and Biosensor, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Division of Health and Applied Sciences, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand
| | - Suparat Cotchim
- Center of Excellence for Trace Analysis and Biosensor, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Center of Excellence for Innovation in Chemistry, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Division of Health and Applied Sciences, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand
| | - Kamonchanok Torrarit
- Center of Excellence for Trace Analysis and Biosensor, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Division of Health and Applied Sciences, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand
| | - Cheng Ho Phua
- Center of Excellence for Trace Analysis and Biosensor, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Center of Excellence for Innovation in Chemistry, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Division of Health and Applied Sciences, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand
| | - Warakorn Limbut
- Center of Excellence for Trace Analysis and Biosensor, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Center of Excellence for Innovation in Chemistry, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Division of Health and Applied Sciences, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Forensic Science Innovation and Service Center, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand.
| |
Collapse
|
2
|
Wang T, Niu J, Pang H, Meng X, Sun R, Xie J. Development of a Portable Residual Chlorine Detection Device with a Combination of Microfluidic Chips and LS-BP Algorithm to Achieve Accurate Detection of Residual Chlorine in Water. MICROMACHINES 2024; 15:1045. [PMID: 39203696 PMCID: PMC11356599 DOI: 10.3390/mi15081045] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/14/2024] [Revised: 08/06/2024] [Accepted: 08/16/2024] [Indexed: 09/03/2024]
Abstract
Chlorine is widely used for sterilization and disinfection of water, but the presence of excess residual chlorine in water poses a substantial threat to human health. At present, there is no portable device which can achieve accurate, rapid, low-cost, and convenient detection of residual chlorine in water. Therefore, it is necessary to develop a device that can perform accurate, rapid, low-cost, and convenient detection of residual chlorine in water. In this study, a portable residual chlorine detection device was developed. A microfluidic chip was studied to achieve efficient mixing of two-phase flow. This microfluidic chip was used for rapid mixing of reagents in the portable residual chlorine detection device, reducing the consumption of reagents, detection time, and device volume. A deep learning algorithm was proposed for predicting residual chlorine concentration in water, achieving precise detection. Firstly, the microfluidic chip structure for detecting mixed reagents was optimized, and the microfluidic chip was fabricated by a 3D-printing method. Secondly, a deep learning (LS-BP) algorithm was constructed and proposed for predicting residual chlorine concentration in water, which can realize dual-channel signal reading. Thirdly, the corresponding portable residual chlorine detection device was developed, and the detection device was compared with residual chlorine detection devices and methods in other studies. The comparison results indicate that the portable residual chlorine detection device has high detection accuracy, fast detection speed, low cost, and good convenience. The excellent performance of the portable residual chlorine detection device makes it suitable for detecting residual chlorine in drinking water, swimming pool water, aquaculture and other fields.
Collapse
Affiliation(s)
- Tongfei Wang
- College of Mechanical and Electronic Engineering, Northwest A&F University, Yangling 712100, China; (T.W.); (H.P.); (X.M.); (R.S.); (J.X.)
| | - Jiping Niu
- College of Water Resources and Architectural Engineering, Northwest A&F University, Yangling 712100, China
| | - Haoran Pang
- College of Mechanical and Electronic Engineering, Northwest A&F University, Yangling 712100, China; (T.W.); (H.P.); (X.M.); (R.S.); (J.X.)
| | - Xiaoyu Meng
- College of Mechanical and Electronic Engineering, Northwest A&F University, Yangling 712100, China; (T.W.); (H.P.); (X.M.); (R.S.); (J.X.)
| | - Ruqian Sun
- College of Mechanical and Electronic Engineering, Northwest A&F University, Yangling 712100, China; (T.W.); (H.P.); (X.M.); (R.S.); (J.X.)
| | - Jiaqing Xie
- College of Mechanical and Electronic Engineering, Northwest A&F University, Yangling 712100, China; (T.W.); (H.P.); (X.M.); (R.S.); (J.X.)
| |
Collapse
|
3
|
Yin J, Gao W, Yu W, Guan Y, Wang Z, Jin Q. A batch microfabrication of a self-cleaning, ultradurable electrochemical sensor employing a BDD film for the online monitoring of free chlorine in tap water. MICROSYSTEMS & NANOENGINEERING 2022; 8:39. [PMID: 35464881 PMCID: PMC8993810 DOI: 10.1038/s41378-022-00359-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/20/2021] [Revised: 12/31/2021] [Accepted: 01/06/2022] [Indexed: 06/14/2023]
Abstract
Free chlorine is one of the key water quality parameters in tap water. However, a free chlorine sensor with the characteristics of batch processing, durability, antibiofouling/antiorganic passivation and in situ monitoring of free chlorine in tap water continues to be a challenging issue. In this paper, a novel silicon-based electrochemical sensor for free chlorine that can self-clean and be mass produced via microfabrication technique/MEMS (Micro-Electro-Mechanical System) is proposed. A liquid-conjugated Ag/AgCl reference electrode is fabricated, and electrochemically stable BDD/Pt is employed as the working/counter electrode to verify the effectiveness of the as-fabricated sensor for free chlorine detection. The sensor demonstrates an acceptable limit of detection (0.056 mg/L) and desirable linearity (R 2 = 0.998). Particularly, at a potential of +2.5 V, hydroxyl radicals are generated on the BBD electrode by electrolyzing water, which then remove the organic matter attached to the surface of the sensor though an electrochemical digestion process. The performance of the fouled sensor recovers from 50.2 to 94.1% compared with the initial state after self-cleaning for 30 min. In addition, by employing the MEMS technique, favorable response consistency and high reproducibility (RSD < 4.05%) are observed, offering the opportunity to mass produce the proposed sensor in the future. A desirable linear dependency between the pH, temperature, and flow rate and the detection of free chlorine is observed, ensuring the accuracy of the sensor with any hydrologic parameter. The interesting sensing and self-cleaning behavior of the as-proposed sensor indicate that this study of the mass production of free chlorine sensors by MEMS is successful in developing a competitive device for the online monitoring of free chlorine in tap water.
Collapse
Affiliation(s)
- Jiawen Yin
- Faculty of Electrical Engineering and Computer Science, Ningbo University, 315211 Ningbo, P. R. China
| | - Wanlei Gao
- Faculty of Electrical Engineering and Computer Science, Ningbo University, 315211 Ningbo, P. R. China
- State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, 200050 Shanghai, P. R. China
| | - Weijian Yu
- Faculty of Electrical Engineering and Computer Science, Ningbo University, 315211 Ningbo, P. R. China
| | - Yihua Guan
- Faculty of Electrical Engineering and Computer Science, Ningbo University, 315211 Ningbo, P. R. China
| | - Zhenyu Wang
- Faculty of Electrical Engineering and Computer Science, Ningbo University, 315211 Ningbo, P. R. China
| | - Qinghui Jin
- Faculty of Electrical Engineering and Computer Science, Ningbo University, 315211 Ningbo, P. R. China
- State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, 200050 Shanghai, P. R. China
| |
Collapse
|