1
|
Gęca I, Korolczuk M. Highly sensitive and selective anodic stripping voltammetric procedure of As(III) determination following double deposition and double stripping steps mode in combination with a flow system. Talanta 2025; 282:126982. [PMID: 39378765 DOI: 10.1016/j.talanta.2024.126982] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2024] [Revised: 09/25/2024] [Accepted: 10/02/2024] [Indexed: 10/10/2024]
Abstract
Double deposition and double stripping steps mode was used for the first time in combination with a flow system for anodic stripping voltammetric determination of As(III) ions. The proposed way of the voltammetric measurements leads to a decrease of the detection limit as compared to the values obtained using a traditional three-electrode system thanks to an initial preconcentration of the analyte on the first working electrode as well as the significant increase of the selectivity of As(III) determination thanks to the application of a flow system. Optimization of the analytical procedure was performed. The calibration curve of As(III) determination was a straight line in the range from 1 × 10-9 to 5 × 10-8 mol L-1. The estimated detection limit was 4.8 × 10-10 mol L-1 (deposition time of 120 s at both working electrodes). The repeatability of the proposed procedure calculated as RSD% for As(III) at a concentration of 1 × 10-8 mol L-1 was 3.8 % (n = 7). The tolerable limit of Cu(II) excess was significantly increased thanks to the solution exchange after the first deposition step. The correctness of the proposed procedure was confirmed by analysis of a real water sample and lake water certified reference material by obtaining satisfactory recovery values.
Collapse
Affiliation(s)
- Iwona Gęca
- Department of Analytical Chemistry, Faculty of Chemistry, Institute of Chemical Sciences, Maria Curie Sklodowska University, Maria Curie Sklodowska sq. 3, 20-031, Lublin, Poland.
| | - Mieczyslaw Korolczuk
- Department of Analytical Chemistry, Faculty of Chemistry, Institute of Chemical Sciences, Maria Curie Sklodowska University, Maria Curie Sklodowska sq. 3, 20-031, Lublin, Poland
| |
Collapse
|
2
|
Xia L, Huang A, Niu X, Wu Z, Tang Y, Zhou J, Wu Y. Laccase-mimicking activity of octahedral Mn 3O 4 nanoparticles and fluorescence of carbon dots as dual-mode signals for the specific detection of arsenic(V) in environmental water samples. THE SCIENCE OF THE TOTAL ENVIRONMENT 2024; 951:175559. [PMID: 39153631 DOI: 10.1016/j.scitotenv.2024.175559] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/16/2024] [Revised: 08/13/2024] [Accepted: 08/13/2024] [Indexed: 08/19/2024]
Abstract
The detrimental growth of water pollutants such as heavy metals has become a life-threatening problem in the modern era. Challenges remain in the development of rapid and accurate methods for detecting pentavalent arsenic [As(V)] in environmental water. The octahedral Mn3O4 nanoparticles (NPs) did not display excellent laccase-mimicking catalytic activity, whereas the adsorbed As(V) on the surface significantly enhanced the catalytic activity. Meanwhile, the quinone imine generated from the substrates 2,4-dichlorophenol (2,4-DP) and 4-aminoantipyrine (4-AAP) catalyzed by octahedral Mn3O4 NPs further quenched the carbon dots fluorescence. Thus, it is possible to establish a fast and accurate dual-mode sensor for detecting As(V). The developed dual-mode method of As(V) detection has good sensitivity and selectivity. The limit of detection for As(V) in colorimetric mode is 6.96 μg·L-1, whereas in the fluorescent mode, it is as low as 2.56 μg·L-1. Moreover, the detection data obtained by the dual-mode method can be validated by each other, thereby ensuring the dependability of the sensing system. The constructed dual-mode method with merits of sensitivity, speed and accuracy can offer a powerful tool for As(V) detection in environmental water. Furthermore, the application of laccase-mimicking activity in dual-mode detection provides new strategies for other environmental hazard detection.
Collapse
Affiliation(s)
- Lian Xia
- Key Laboratory of Plant Resource Conservation and Germplasm Innovation in Mountainous Region (Ministry of Education), College of Life Sciences/Institute of Agro-bioengineering, Guizhou University, Guiyang 550025, China
| | - Andi Huang
- Guizhou Province Key Laboratory of Fermentation Engineering and Biopharmacy, School of Liquor and Food Engineering, Guizhou University, Guiyang 550025, China
| | - Xiaojuan Niu
- Key Laboratory of Plant Resource Conservation and Germplasm Innovation in Mountainous Region (Ministry of Education), College of Life Sciences/Institute of Agro-bioengineering, Guizhou University, Guiyang 550025, China; College of Life Sciences, Guizhou Normal University, Guiyang 550025, China
| | - Zhen Wu
- Key Laboratory of Plant Resource Conservation and Germplasm Innovation in Mountainous Region (Ministry of Education), College of Life Sciences/Institute of Agro-bioengineering, Guizhou University, Guiyang 550025, China
| | - Yue Tang
- Key Laboratory of Plant Resource Conservation and Germplasm Innovation in Mountainous Region (Ministry of Education), College of Life Sciences/Institute of Agro-bioengineering, Guizhou University, Guiyang 550025, China
| | - Jianli Zhou
- Guizhou Province Key Laboratory of Fermentation Engineering and Biopharmacy, School of Liquor and Food Engineering, Guizhou University, Guiyang 550025, China
| | - Yuangen Wu
- Key Laboratory of Plant Resource Conservation and Germplasm Innovation in Mountainous Region (Ministry of Education), College of Life Sciences/Institute of Agro-bioengineering, Guizhou University, Guiyang 550025, China; Guizhou Province Key Laboratory of Fermentation Engineering and Biopharmacy, School of Liquor and Food Engineering, Guizhou University, Guiyang 550025, China.
| |
Collapse
|
3
|
Rauf M, Shah SK, Algahtani A, Tirth V, Alghtani AH, Al-Mughanam T, Hayat K, Al-Shaalan NH, Alharthi S, Alharthy SA, Amin MA. Application of ZnO-NRs@Ni-foam substrate for electrochemical fingerprint of arsenic detection in water. RSC Adv 2023; 13:14530-14538. [PMID: 37188253 PMCID: PMC10176428 DOI: 10.1039/d3ra01574b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2023] [Accepted: 04/25/2023] [Indexed: 05/17/2023] Open
Abstract
Arsenic (As3+) is the most carcinogenic and abundantly available heavy metal present in the environment. Vertically aligned ZnO nanorod (ZnO-NR) growth was achieved on metallic nickel foam substrate via a wet chemical route and it was used as an electrochemical sensor towards As(iii) detection in polluted water. Crystal structure confirmation, surface morphology observation and elemental analysis of ZnO-NRs were conducted using X-ray diffraction, field-emission scanning electron microscopy and energy-dispersive X-ray spectroscopy, respectively. Electrochemical sensing performance of ZnO-NRs@Ni-foam electrode/substrate was investigated via linear sweep voltammetry, cyclic voltammetry and electrochemical impedance spectroscopy in a carbonate buffer solution of pH = 9 and at different As(iii) molar concentrations in solution. Under optimum conditions, the anodic peak current was found proportional to the arsenite concentration from 0.1 μM to 1.0 μM. The achieved values for limit of detection and limit of quantification were 0.046 ppm and 0.14 ppm, respectively, which are far lower than the recommended limits for As(iii) detection in drinking water as suggested by the World Health Organization. This suggests that ZnO-NRs@Ni-foam electrode/substrate can be effectively utilized in terms of its electrocatalytic activity towards As3+ detection in drinking water.
Collapse
Affiliation(s)
- Muhammad Rauf
- Department of Physics, Abdul Wali Khan University Mardan 23200 Mardan Khyber Pakhtunkhwa Pakistan
| | - Said Karim Shah
- Department of Physics, Abdul Wali Khan University Mardan 23200 Mardan Khyber Pakhtunkhwa Pakistan
| | - Ali Algahtani
- Mechanical Engineering Department, College of Engineering, King Khalid University Abha 61421 Asir Kingdom of Saudi Arabia
- Research Center for Advanced Materials Science (RCAMS), King Khalid University Guraiger, PO Box 9004 Abha 61413 Asir Kingdom of Saudi Arabia
| | - Vineet Tirth
- Mechanical Engineering Department, College of Engineering, King Khalid University Abha 61421 Asir Kingdom of Saudi Arabia
- Research Center for Advanced Materials Science (RCAMS), King Khalid University Guraiger, PO Box 9004 Abha 61413 Asir Kingdom of Saudi Arabia
| | - Abdulaziz H Alghtani
- Department of Mechanical Engineering, College of Engineering, Taif University PO Box 11099 Taif 21944 Kingdom of Saudi Arabia
| | - Tawfiq Al-Mughanam
- Department of Mechanical Engineering, College of Engineering, King Faisal University PO Box 380 Al-Ahsa 31982 Kingdom of Saudi Arabia
| | - Khizar Hayat
- Department of Physics, Abdul Wali Khan University Mardan 23200 Mardan Khyber Pakhtunkhwa Pakistan
| | - Nora Hamad Al-Shaalan
- Department of Chemistry, College of Science, Princess Nourah Bint Abdulrahman University PO Box 84428 Riyadh 11671 Saudi Arabia
| | - Sarah Alharthi
- Department of Chemistry, College of Science, Taif University PO Box 11099 Taif 21944 Saudi Arabia
- Center of Advanced Research in Science and Technology, Taif University PO Box 11099 Taif 21944 Saudi Arabia
| | - Saif A Alharthy
- Department of Medical Laboratory Sciences, Faculty of Applied Medical Sciences, King Abdulaziz University PO Box 80216 Jeddah 21589 Saudi Arabia
- King Fahd Medical Research Center, King Abdulaziz University PO Box 80216 Jeddah 21589 Saudi Arabia
| | - Mohammed A Amin
- Department of Chemistry, College of Science, Taif University PO Box 11099 Taif 21944 Saudi Arabia
| |
Collapse
|
4
|
Ivanišević I. The Role of Silver Nanoparticles in Electrochemical Sensors for Aquatic Environmental Analysis. SENSORS (BASEL, SWITZERLAND) 2023; 23:3692. [PMID: 37050752 PMCID: PMC10099384 DOI: 10.3390/s23073692] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/28/2023] [Revised: 03/30/2023] [Accepted: 03/31/2023] [Indexed: 06/19/2023]
Abstract
With rapidly increasing environmental pollution, there is an urgent need for the development of fast, low-cost, and effective sensing devices for the detection of various organic and inorganic substances. Silver nanoparticles (AgNPs) are well known for their superior optoelectronic and physicochemical properties, and have, therefore, attracted a great deal of interest in the sensor arena. The introduction of AgNPs onto the surface of two-dimensional (2D) structures, incorporation into conductive polymers, or within three-dimensional (3D) nanohybrid architectures is a common strategy to fabricate novel platforms with improved chemical and physical properties for analyte sensing. In the first section of this review, the main wet chemical reduction approaches for the successful synthesis of functional AgNPs for electrochemical sensing applications are discussed. Then, a brief section on the sensing principles of voltammetric and amperometric sensors is given. The current utilization of silver nanoparticles and silver-based composite nanomaterials for the fabrication of voltammetric and amperometric sensors as novel platforms for the detection of environmental pollutants in water matrices is summarized. Finally, the current challenges and future directions for the nanosilver-based electrochemical sensing of environmental pollutants are outlined.
Collapse
Affiliation(s)
- Irena Ivanišević
- Department of General and Inorganic Chemistry, Faculty of Chemical Engineering and Technology, University of Zagreb, Marulićev trg 19, 10000 Zagreb, Croatia
| |
Collapse
|
5
|
C. G AM, Agnihotri AS, Varghese A, M N. Ion-imprinted chitosan-stabilized biogenic silver nanoparticles for the electrochemical detection of arsenic ( iii) in water samples. NEW J CHEM 2023. [DOI: 10.1039/d2nj04804c] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/25/2023]
Abstract
A schematic representation showing the modified glassy carbon electrode for the detection of arsenic (iii) in water samples.
Collapse
Affiliation(s)
- Ann Maria. C. G
- Department of Chemistry, CHRIST (Deemed to be University), Bengaluru-560029, India
| | - Ananya S Agnihotri
- Department of Chemistry, CHRIST (Deemed to be University), Bengaluru-560029, India
| | - Anitha Varghese
- Department of Chemistry, CHRIST (Deemed to be University), Bengaluru-560029, India
| | - Nidhin M
- Department of Chemistry, CHRIST (Deemed to be University), Bengaluru-560029, India
| |
Collapse
|
6
|
Keser K, Soylu MÇ. Detection of Phenylarsine Oxide in Drinking Water Using an Impedimetric Electrochemical Sensor with Gelatin-Based Solid Electrolyte Enriched with Mercaptoethanol: A Novel Prospective Green Biosensor Methodology. ACS OMEGA 2022; 7:43111-43121. [PMID: 36467944 PMCID: PMC9713887 DOI: 10.1021/acsomega.2c05516] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/26/2022] [Accepted: 11/04/2022] [Indexed: 06/17/2023]
Abstract
A simple, inexpensive, rapid, and label-free detection of phenylarsine oxide (PAO) in the field is a significant and unmet need because of its fatally acute and chronic effects on human health. A simple, fast, sensitive, and relatively low-cost arsenic detection system with an eco-friendly sensor could fill this gap. To monitor arsenic in situ, a reliable, portable impedimetric electrochemical sensor is the most suitable platform, which is real-time, fast, low-cost, and easy to design and use and has high sensitivity at low detection limits in the nanogram per mL range. The detection system in this study has a patent-applied green sensor with minimum harm to nature and the potential to dissolve in nature. The electrode containing 15 mL of distilled water (DIW) + 2 g gelatin + 1.75 g glycerol was determined to be the most suitable for determining the amount of inorganic arsenic in the range of 1-100 ng/mL using a gelatin-based solid electrochemical sensor enriched with 2-mercaptoethanol. Impedance measurements were performed to analyze the stability of the sensor in both deionized water and drinking water, as well as for arsenic detection. Among the procedures examined, the procedure prepared with 15 mL DIW + 2 g glycerol + 1.75 g gelatin resulted in the best stability in aqueous medium and in sensitivity with resistance changes (-ΔR ct (%)) of 12% (±0.62%), 26% (±2.3%), and 40% (±3.8%) for the concentrations of 1, 10, and 100 ng/mL PAO in drinking water, respectively. With this detection methodology, there is the potential to detect not only arsenic but also other heavy metals in waters and different biomarkers in human fluids.
Collapse
Affiliation(s)
- Kübra Keser
- Biomedical
Device Technologies, Simav Vocational School, Kutahya Dumlupinar University, Simav, Kütahya43500, Turkey
| | - Mehmet Çağrı Soylu
- Biological
and Medical Diagnostic Sensors Laboratory (BioMeD Sensors Lab), Department
of Biomedical Engineering, Erciyes University, Kayseri38039, Turkey
| |
Collapse
|
7
|
Kumari B, Bharti VK. Recent advancements in toxicology, modern technology for detection, and remedial measures for arsenic exposure: review. Biotechnol Genet Eng Rev 2022:1-43. [PMID: 36411979 DOI: 10.1080/02648725.2022.2147664] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2022] [Accepted: 10/15/2022] [Indexed: 11/23/2022]
Abstract
Arsenic toxicity has become a major global health concern for humans and animals due to extensive environmental and occupational exposure to arsenic-contaminated water, air, soil, and plant and animal origin food. It has a wide range of detrimental effects on animals, humans, and the environment. As a result, various experimental and clinical studies were undertaken and are undergoing to understand its source of exposures, pathogenesis, identify key biomarkers, the medical and economic impact on affected populations and ecosystems, and their timely detection and control measures. Despite these extensive studies, no conclusive information for the prevention and control of arsenic toxicity is available, owing to complex epidemiology and pathogenesis, including an imprecise approach and repetitive work. As a result, there is a need for literature that focuses on recent studies on the epidemiology, pathogenesis, detection, and ameliorative measures of arsenic toxicity to assist researchers and policymakers in the practical future planning of research and community control programs. According to the preceding viewpoint, this review article provides an extensive analysis of the recent progress on arsenic exposure to humans through the environment, livestock, and fish, arsenic toxicopathology, nano-biotechnology-based detection, and current remedial measures for the benefit of researchers, academicians, and policymakers in controlling arsenic eco-toxicology and directing future research. Arsenic epidemiology should therefore place the greatest emphasis on the prevalence of different direct and indirect sources in the afflicted areas, followed by control strategies.
Collapse
Affiliation(s)
- Bibha Kumari
- Department of Zoology, Magadh Mahila College, Patna University, Patna, India
| | - Vijay K Bharti
- DRDO-Defence Institute of High-Altitude Research (DIHAR), Leh, UT Ladakh, India
| |
Collapse
|
8
|
Pasha SS, Banerjee A, Sreedharan S, Singh S, Kandoth N, Vallis KA, Pal SK, Pramanik SK, Das A. Ultrasensitive Reagent for Ratiometric Detection and Detoxification of iAsIII in Water and Mitochondria. Inorg Chem 2022; 61:13115-13124. [PMID: 35950896 DOI: 10.1021/acs.inorgchem.2c01761] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
Toxicity induced by inorganic arsenic as AsO33- (iAsIII) is of global concern. Reliable detection of the maximum allowed contaminant level for arsenic in drinking water and in the cellular system remains a challenge for the water quality management and assessment of toxicity in the cellular milieu, respectively. A new Ir(III)-based phosphorescent molecule (AS-1; λExt = 415 nm and λEms = 600 nm, Φ = 0.3) is synthesized for the selective detection of iAsIII in an aqueous solution with a ratiometric luminescence response even in the presence of iAsV and all other common inorganic cations and anions. The relatively higher affinity of the thioimidazole ligand (HPBT) toward iAsIII led to the formation of a fluorescent molecule iAsV-HPBT (λExt = 415 nm and λEms = 466 nm, Φ = 0.28) for the reaction of iAsIII and AS-1. An improved limit of quantitation (LOQ) down to 0.2 ppb is achieved when AS-1 is used in the CTAB micellar system. Presumably, the cationic surfactants favor the localization of AS-1@CTABMicelle in mitochondria of MCF7 cells, and this is confirmed from the images of the confocal laser fluorescence scanning microscopic studies. Importantly, cell viability assay studies confirm that AS-1@CTABMicelle induces dose-dependent detoxification of iAsIII in live cells. Further, luminescence responses at 466 nm could be utilized for developing a hand-held device for the in-field application. Such a reagent that allows for ratiometric detection of iAsIII with LOQ of 2.6 nM (0.5 ppb) in water, as well as helps in visualizing its distribution in mitochondria with a detoxifying effect, is rather unique in contemporary literature.
Collapse
Affiliation(s)
- Sheik Saleem Pasha
- Central Salt and Marine Chemicals Research Institute, Bhavnagar 364002, Gujarat, India
| | - Amrita Banerjee
- Technical Research Centre, Department of Chemical, Biological & Macromolecular Sciences, S. N. Bose National Centre for Basic Sciences, Block JD, Sector III, Salt Lake, Kolkata, West Bengal 700106, India
| | - Sreejesh Sreedharan
- Oxford Institute for Radiation Oncology, University of Oxford, Oxford OX3 7DQ, U.K.,Human Sciences Research Centre, University of Derby, Derby DE221GB, U.K
| | - Soumendra Singh
- Technical Research Centre, Department of Chemical, Biological & Macromolecular Sciences, S. N. Bose National Centre for Basic Sciences, Block JD, Sector III, Salt Lake, Kolkata, West Bengal 700106, India
| | - Noufal Kandoth
- Indian Institute of Science Education and Research Kolkata, Mohanpur 741246, West Bengal, India
| | - Katherine A Vallis
- Oxford Institute for Radiation Oncology, University of Oxford, Oxford OX3 7DQ, U.K
| | - Samir Kumar Pal
- Technical Research Centre, Department of Chemical, Biological & Macromolecular Sciences, S. N. Bose National Centre for Basic Sciences, Block JD, Sector III, Salt Lake, Kolkata, West Bengal 700106, India
| | - Sumit Kumar Pramanik
- Central Salt and Marine Chemicals Research Institute, Bhavnagar 364002, Gujarat, India.,Academy of Scientific and Innovative Research (AcSIR), Ghaziabad 201002, India
| | - Amitava Das
- Indian Institute of Science Education and Research Kolkata, Mohanpur 741246, West Bengal, India.,Academy of Scientific and Innovative Research (AcSIR), Ghaziabad 201002, India
| |
Collapse
|
9
|
Silver nanoparticles modified electrodes for electroanalysis: An updated review and a perspective. Microchem J 2022. [DOI: 10.1016/j.microc.2021.107166] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/21/2023]
|
10
|
Hu H, Xie B, Lu Y, Zhu J. Advances in Electrochemical Detection Electrodes for As(III). NANOMATERIALS (BASEL, SWITZERLAND) 2022; 12:781. [PMID: 35269271 PMCID: PMC8912440 DOI: 10.3390/nano12050781] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/27/2022] [Revised: 02/12/2022] [Accepted: 02/17/2022] [Indexed: 02/01/2023]
Abstract
Arsenic is extremely abundant in the Earth's crust and is one of the most common environmental pollutants in nature. In the natural water environment and surface soil, arsenic exists mainly in the form of trivalent arsenite (As(III)) and pentavalent arsenate (As(V)) ions, and its toxicity can be a serious threat to human health. In order to manage the increasingly serious arsenic pollution in the living environment and maintain a healthy and beautiful ecosystem for human beings, it is urgent to conduct research on an efficient sensing method suitable for the detection of As(III) ions. Electrochemical sensing has the advantages of simple instrumentation, high sensitivity, good selectivity, portability, and the ability to be analyzed on site. This paper reviews various electrode systems developed in recent years based on nanomaterials such as noble metals, bimetals, other metals and their compounds, carbon nano, and biomolecules, with a focus on electrodes modified with noble metal and metal compound nanomaterials, and evaluates their performance for the detection of arsenic. They have great potential for achieving the rapid detection of arsenic due to their excellent sensitivity and strong interference immunity. In addition, this paper discusses the relatively rare application of silicon and its compounds as well as novel polymers in achieving arsenic detection, which provides new ideas for investigating novel nanomaterial sensing. We hope that this review will further advance the research progress of high-performance arsenic sensors based on novel nanomaterials.
Collapse
Affiliation(s)
- Haibing Hu
- Academy of Opto-Electric Technology, Special Display and Imaging Technology Innovation Center of Anhui Province, National Engineering Laboratory of Special Display Technology, State Key Laboratory of Advanced Display Technology, Collaborative Innovation Center of Advanced Display Technology, Anhui Key Laboratory of Advanced Imaging and Display Technology, Opto-Electric Display Industry Innovation Center, Anhui Province Key Laboratory of Measuring Theory and Precision Instrument, School of Instrument Science and Optoelectronics Engineering, Hefei University of Technology, Hefei 230009, China; (B.X.); (Y.L.)
| | - Baozhu Xie
- Academy of Opto-Electric Technology, Special Display and Imaging Technology Innovation Center of Anhui Province, National Engineering Laboratory of Special Display Technology, State Key Laboratory of Advanced Display Technology, Collaborative Innovation Center of Advanced Display Technology, Anhui Key Laboratory of Advanced Imaging and Display Technology, Opto-Electric Display Industry Innovation Center, Anhui Province Key Laboratory of Measuring Theory and Precision Instrument, School of Instrument Science and Optoelectronics Engineering, Hefei University of Technology, Hefei 230009, China; (B.X.); (Y.L.)
| | - Yangtian Lu
- Academy of Opto-Electric Technology, Special Display and Imaging Technology Innovation Center of Anhui Province, National Engineering Laboratory of Special Display Technology, State Key Laboratory of Advanced Display Technology, Collaborative Innovation Center of Advanced Display Technology, Anhui Key Laboratory of Advanced Imaging and Display Technology, Opto-Electric Display Industry Innovation Center, Anhui Province Key Laboratory of Measuring Theory and Precision Instrument, School of Instrument Science and Optoelectronics Engineering, Hefei University of Technology, Hefei 230009, China; (B.X.); (Y.L.)
| | - Jianxiong Zhu
- School of Mechanical Engineering, Southeast University, Nanjing 211189, China
| |
Collapse
|
11
|
A covalent organic framework containing bipyridine groups as a fluorescent chemical probe for the ultrasensitive detection of arsenic (III). J Photochem Photobiol A Chem 2021. [DOI: 10.1016/j.jphotochem.2021.113528] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
12
|
Zhang Y, Li D, Compton RG. Arsenic (III) Detection with Underpotential Deposition and Anodic Stripping Voltammetry. ChemElectroChem 2021. [DOI: 10.1002/celc.202101022] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Affiliation(s)
- Yifei Zhang
- Department of Chemistry Physical and Theoretical Chemistry Laboratory Oxford University South Parks Road Oxford OX1 3QZ UK
| | - Danlei Li
- Department of Chemistry Physical and Theoretical Chemistry Laboratory Oxford University South Parks Road Oxford OX1 3QZ UK
| | - Richard G. Compton
- Department of Chemistry Physical and Theoretical Chemistry Laboratory Oxford University South Parks Road Oxford OX1 3QZ UK
| |
Collapse
|
13
|
Duoc PND, Binh NH, Hau TV, Thanh CT, Trinh PV, Tuyen NV, Quynh NV, Tu NV, Duc Chinh V, Thi Thu V, Thang PD, Minh PN, Chuc NV. A novel electrochemical sensor based on double-walled carbon nanotubes and graphene hybrid thin film for arsenic(V) detection. JOURNAL OF HAZARDOUS MATERIALS 2020; 400:123185. [PMID: 32563905 DOI: 10.1016/j.jhazmat.2020.123185] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/29/2019] [Revised: 06/08/2020] [Accepted: 06/08/2020] [Indexed: 06/11/2023]
Abstract
In this work, we demonstrate the preparation of hybrid thin films based on double-walled carbon nanotubes and graphene for electrochemical sensing applications. The hybrid films were synthesized on polycrystalline copper foil by thermal chemical vapor deposition under low pressure. This carbonaceous hybrid film has exhibited high transparency with a transmittance of 94.3 %. The occurrence of this hybrid material on the electrode surface of screen-printed electrodes was found to increase electroactive surface area by 1.4 times, whereas electrochemical current was enhanced by 2.4 times. Such a highly transparent and conductive hybrid film was utilized as a transducing platform of enzymatic electrochemical arsenic(V) sensor. The as-prepared sensor shows the linear detection of arsenic(V) in the range from 1 to 10 ppb, with a limit of detection as low as 0.287 ppb. These findings provide a promising approach to develop new multifunctional electrochemical sensing systems for environmental monitoring and biomedical diagnostics.
Collapse
Affiliation(s)
- Phan Nguyen Duc Duoc
- Institute of Materials Science, Vietnam Academy of Science and Technology, 18 Hoang Quoc Viet, Cau Giay, Hanoi, Vietnam; VNU-University of Engineering and Technology, 144 Xuan Thuy, Cau Giay, Hanoi, Vietnam; Department of Physics, Nha Trang University, 02 Nguyen Dinh Chieu, Nha Trang, Vietnam
| | - Nguyen Hai Binh
- Institute of Materials Science, Vietnam Academy of Science and Technology, 18 Hoang Quoc Viet, Cau Giay, Hanoi, Vietnam
| | - Tran Van Hau
- Institute of Materials Science, Vietnam Academy of Science and Technology, 18 Hoang Quoc Viet, Cau Giay, Hanoi, Vietnam; VNU-University of Engineering and Technology, 144 Xuan Thuy, Cau Giay, Hanoi, Vietnam
| | - Cao Thi Thanh
- Institute of Materials Science, Vietnam Academy of Science and Technology, 18 Hoang Quoc Viet, Cau Giay, Hanoi, Vietnam
| | - Pham Van Trinh
- Institute of Materials Science, Vietnam Academy of Science and Technology, 18 Hoang Quoc Viet, Cau Giay, Hanoi, Vietnam
| | - Nguyen Viet Tuyen
- Faculty of Physics, VNU University of Science, Vietnam National University, Hanoi, 334 Nguyen Trai, Thanh Xuan, Hanoi, Vietnam
| | - Nguyen Van Quynh
- University of Science and Technology of Hanoi, Vietnam Academy of Science and Technology, 18 Hoang Quoc Viet, Cau Giay, Hanoi, Vietnam
| | - Nguyen Van Tu
- Institute of Materials Science, Vietnam Academy of Science and Technology, 18 Hoang Quoc Viet, Cau Giay, Hanoi, Vietnam
| | - Vu Duc Chinh
- Institute of Materials Science, Vietnam Academy of Science and Technology, 18 Hoang Quoc Viet, Cau Giay, Hanoi, Vietnam
| | - Vu Thi Thu
- University of Science and Technology of Hanoi, Vietnam Academy of Science and Technology, 18 Hoang Quoc Viet, Cau Giay, Hanoi, Vietnam
| | - Pham Duc Thang
- VNU-University of Engineering and Technology, 144 Xuan Thuy, Cau Giay, Hanoi, Vietnam
| | - Phan Ngoc Minh
- Institute of Materials Science, Vietnam Academy of Science and Technology, 18 Hoang Quoc Viet, Cau Giay, Hanoi, Vietnam; Graduate University of Science and Technology, Vietnam Academy of Science and Technology, 18 Hoang Quoc Viet, Cau Giay, Hanoi, Vietnam; Center for High Technology Development, Vietnam Academy of Science and Technology, 18 Hoang Quoc Viet, Cau Giay, Hanoi, Vietnam
| | - Nguyen Van Chuc
- Institute of Materials Science, Vietnam Academy of Science and Technology, 18 Hoang Quoc Viet, Cau Giay, Hanoi, Vietnam; Graduate University of Science and Technology, Vietnam Academy of Science and Technology, 18 Hoang Quoc Viet, Cau Giay, Hanoi, Vietnam.
| |
Collapse
|
14
|
Núñez C, José Triviño J, Segura R, Arancibia V. Development of a fast and sensitive method for the determination of As(III) at trace levels in urine by differential pulse anodic voltammetry using a simple graphene screen–printed electrode. Microchem J 2020. [DOI: 10.1016/j.microc.2020.105393] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
|
15
|
Tang Q, Zhu G, Ge Y, Yang J, Huang M, Liu J. AuNPs-polyaniline nanosheet array on carbon nanofiber for the determination of As(III). J Electroanal Chem (Lausanne) 2020. [DOI: 10.1016/j.jelechem.2020.114381] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
|