1
|
Manandhar S, Yrjänä V, Leito I, Bobacka J. Determination of benzoate in cranberry and lingonberry by using a solid-contact benzoate-selective electrode. Talanta 2024; 274:125996. [PMID: 38574535 DOI: 10.1016/j.talanta.2024.125996] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2023] [Revised: 03/15/2024] [Accepted: 03/25/2024] [Indexed: 04/06/2024]
Abstract
Benzoic acid is used as a preservative in processed food, and occasionally in cosmetics and pharmaceuticals, while benzoic acid occurs naturally in, e.g., cranberry and lingonberry. Therefore, the determination of benzoate is of interest for product quality assurance, food safety, and personal health. In this work, a solid-contact benzoate-selective electrode (benzoate-ISE) was developed by utilising poly(3,4-ethylenedioxythiophene) (PEDOT) as solid contact and a solvent polymeric membrane containing a 1,3-bis(carbazolyl)urea derivative as ionophore. The benzoate-ISE was characterised in parallel with an ionophore-free control-ISE by electrochemical impedance spectroscopy and potentiometry. The presence of the ionophore in the membrane improved the selectivity to benzoate. Benzoate-ISEs and control-ISEs were used further to determine the benzoate concentration in cranberry and lingonberry by standard addition. The results obtained with both types of ISEs were compared with those obtained by ion chromatography. The results obtained with benzoate-ISEs were consistent with those obtained with ion chromatography. On the contrary, the control-ISE (without ionophore) gave significantly higher benzoate concentrations, especially in the case of cranberry where the benzoate concentration was low (ca 0.2 g kg-1) compared to lingonberry (ca 1 g kg-1). Hence, the benzoate-selectivity of the ionophore was crucial to obtain a benzoate-ISE that was practically applicable for determination of benzoate concentrations in cranberry and lingonberry.
Collapse
Affiliation(s)
- Sajana Manandhar
- Laboratory of Molecular Science and Engineering, Johan Gadolin Process Chemistry Centre, Faculty of Science and Engineering, Åbo Akademi University, Henriksgatan 2, FI-20500, Turku, (Åbo), Finland; Institute of Chemistry, University of Tartu, Ravila 14a, 50411, Tartu, Estonia
| | - Ville Yrjänä
- Laboratory of Molecular Science and Engineering, Johan Gadolin Process Chemistry Centre, Faculty of Science and Engineering, Åbo Akademi University, Henriksgatan 2, FI-20500, Turku, (Åbo), Finland
| | - Ivo Leito
- Institute of Chemistry, University of Tartu, Ravila 14a, 50411, Tartu, Estonia
| | - Johan Bobacka
- Laboratory of Molecular Science and Engineering, Johan Gadolin Process Chemistry Centre, Faculty of Science and Engineering, Åbo Akademi University, Henriksgatan 2, FI-20500, Turku, (Åbo), Finland.
| |
Collapse
|
2
|
Oziat J, Babin T, Gougis M, Malliaras GG, Mailley P. Electrochemical detection of redox molecules secreted by Pseudomonas aeruginosa - Part 2: Enhanced detection owing to PEDOT:PSS electrode structuration. Bioelectrochemistry 2023; 154:108538. [PMID: 37549554 DOI: 10.1016/j.bioelechem.2023.108538] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2022] [Revised: 07/29/2023] [Accepted: 08/02/2023] [Indexed: 08/09/2023]
Abstract
Fast bacterial detection and identification is a crucial challenge in order to improve our antibiotics use and reduce the antimicrobial resistance. Electroanalysis of biological fluids is cheap and can be done in situ but the electrode material needs to be perfectly chosen. We previously studied electrochemical signature of Pseudomonas aeruginosa's secretome, thanks to glassy carbon electrode. Some conductive polymers are particularly efficient for biological use because of their antifouling properties, biocompatibility and way of processing. In this paper, we described the fabrication, characterization and utilisation of PEDOT:PSS film to detect and identify Pseudomonas aeruginosa through three of its secreted molecules: pyocyanin, Pseudomonas quinolone PQS and 2'-aminoacetophenone. The electrochemical responses, clearly amplified by PEDOT:PSS, can be used to identify these bacteria quickly and efficiently.
Collapse
Affiliation(s)
- Julie Oziat
- CEA, Leti, MINATEC Campus, F-38054 Grenoble, France; Department of Bioelectronics, Ecole Nationale Supérieure des Mines de Saint-Etienne, F-13541 Gardanne, France; Bioserenity, 47 Bd de l'Hopital, F-75013 Paris, France
| | | | | | - George G Malliaras
- Department of Bioelectronics, Ecole Nationale Supérieure des Mines de Saint-Etienne, F-13541 Gardanne, France; Electrical Engineering Division, Department of Engineering, University of Cambridge, Cambridge CB3 0FA, UK
| | | |
Collapse
|
3
|
Wardak C, Morawska K, Pietrzak K. New Materials Used for the Development of Anion-Selective Electrodes-A Review. MATERIALS (BASEL, SWITZERLAND) 2023; 16:5779. [PMID: 37687472 PMCID: PMC10488487 DOI: 10.3390/ma16175779] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/24/2023] [Revised: 08/13/2023] [Accepted: 08/21/2023] [Indexed: 09/10/2023]
Abstract
Ion-selective electrodes are a popular analytical tool useful in the analysis of cations and anions in environmental, industrial and clinical samples. This paper presents an overview of new materials used for the preparation of anion-sensitive ion-selective electrodes during the last five years. Design variants of anion-sensitive electrodes, their advantages and disadvantages as well as research methods used to assess their parameters and analytical usefulness are presented. The work is divided into chapters according to the type of ion to which the electrode is selective. Characteristics of new ionophores used as the electroactive component of ion-sensitive membranes and other materials used to achieve improvement of sensor performance (e.g., nanomaterials, composite and hybrid materials) are presented. Analytical parameters of the electrodes presented in the paper are collected in tables, which allows for easy comparison of different variants of electrodes sensitive to the same ion.
Collapse
Affiliation(s)
- Cecylia Wardak
- Department of Analytical Chemistry, Institute of Chemical Sciences, Faculty of Chemistry, Maria Curie-Sklodowska University, Maria Curie-Sklodowska Sq. 3, 20-031 Lublin, Poland;
| | - Klaudia Morawska
- Department of Analytical Chemistry, Institute of Chemical Sciences, Faculty of Chemistry, Maria Curie-Sklodowska University, Maria Curie-Sklodowska Sq. 3, 20-031 Lublin, Poland;
| | - Karolina Pietrzak
- Department of Food and Nutrition, Medical University of Lublin, 4a Chodzki Str., 20-093 Lublin, Poland;
| |
Collapse
|
4
|
Neo ZH, Seah GEKK, Ng SH, Safanama D, Seng DHL, Goh SS. Solution-Printable PEDOT Solid-Contact for Nitrate-Selective Electrodes: Enhanced Selectivity from Anion Dopant Exchange. Anal Chem 2022; 94:15956-15963. [DOI: 10.1021/acs.analchem.2c02119] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Affiliation(s)
- Zhi Hao Neo
- Institute of Material Research and Engineering, A*STAR (Agency for Science, Technology and Research) Research Entities, 2 Fusionopolis Way, Innovis #08-03, Singapore138634, Singapore
| | - Georgina E. K. K. Seah
- Institute of Material Research and Engineering, A*STAR (Agency for Science, Technology and Research) Research Entities, 2 Fusionopolis Way, Innovis #08-03, Singapore138634, Singapore
| | - Shi Hoe Ng
- Institute of Material Research and Engineering, A*STAR (Agency for Science, Technology and Research) Research Entities, 2 Fusionopolis Way, Innovis #08-03, Singapore138634, Singapore
| | - Dorsasadat Safanama
- Institute of Material Research and Engineering, A*STAR (Agency for Science, Technology and Research) Research Entities, 2 Fusionopolis Way, Innovis #08-03, Singapore138634, Singapore
| | - Debbie H. L. Seng
- Institute of Material Research and Engineering, A*STAR (Agency for Science, Technology and Research) Research Entities, 2 Fusionopolis Way, Innovis #08-03, Singapore138634, Singapore
| | - Shermin S. Goh
- Institute of Material Research and Engineering, A*STAR (Agency for Science, Technology and Research) Research Entities, 2 Fusionopolis Way, Innovis #08-03, Singapore138634, Singapore
| |
Collapse
|
5
|
Rüütel A, Tshepelevitsh S, Leito I. One Hundred Carboxylate Receptors. J Org Chem 2022; 87:14186-14193. [PMID: 36214741 DOI: 10.1021/acs.joc.2c01725] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
Abstract
This work presents a compilation of binding constant (logKass) values in DMSO-d6/H2O (0.5% m/m) for a variety of receptors with 12 carboxylate anions (formate, acetate, lactate, pivalate, sorbate, hexanoate, benzoate, glyphosate, glucuronate, ibuprofen, naproxen, and ketoprofen). A total of 489 logKass values are listed for 100 anion receptor molecules. Most logKass values originate from previously published articles, along with some values for previously unpublished receptor molecules, spanning a workflow of 8 years. The purpose of this study is to serve as a comprehensive information source for selecting suitable receptor candidates to be used in practical carboxylate sensing applications, such as constructing ion-selective electrodes (ISE-s). To support such decision making, all receptors are presented together with lipophilicity (logPo/w) data.
Collapse
Affiliation(s)
- Alo Rüütel
- Institute of Chemistry, University of Tartu, Ravila 14a, 50411Tartu, Estonia
| | - Sofja Tshepelevitsh
- Institute of Chemistry, University of Tartu, Ravila 14a, 50411Tartu, Estonia
| | - Ivo Leito
- Institute of Chemistry, University of Tartu, Ravila 14a, 50411Tartu, Estonia
| |
Collapse
|
6
|
Han T, Mattinen U, Mousavi Z, Bobacka J. Coulometric response of solid-contact anion-sensitive electrodes. Electrochim Acta 2021. [DOI: 10.1016/j.electacta.2020.137566] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|
7
|
Potentiometric Carboxylate Sensors Based on Carbazole-Derived Acyclic and Macrocyclic Ionophores. CHEMOSENSORS 2020. [DOI: 10.3390/chemosensors9010004] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Solid-contact ion-selective electrodes with carbazole-derived ionophores were prepared. They were characterized as acetate sensors, but can be used to determine a number of carboxylates. The potentiometric response characteristics (slope, detection limit, selectivity, and pH sensitivity) of sensors prepared with different membrane compositions (ionophore, ionophore concentration, anion exchanger concentration, and plasticizer) were evaluated. The results show that for the macrocyclic ionophores, a larger cavity provided better selectivity. The sensors exhibited modest selectivity for acetate but good selectivity for benzoate. The carbazole-derived ionophores effectively decreased the interference from lipophilic anions, such as bromide, nitrate, iodide, and thiocyanate. The selectivity, detection limit, and linear range were improved by choosing a suitable plasticizer and by reducing the ionophore and anion exchanger concentrations. The influence of the electrode body’s material upon the composition of the plasticized poly(vinyl chloride) membrane, and thus also upon the sensor characteristics, was also studied. The choice of materials for the electrode body significantly affected the characteristics of the sensors.
Collapse
|
8
|
Affiliation(s)
- Elena Zdrachek
- Department of Inorganic and Analytical Chemistry, University of Geneva, Quai Ernest-Ansermet 30, CH-1211 Geneva, Switzerland
| | - Eric Bakker
- Department of Inorganic and Analytical Chemistry, University of Geneva, Quai Ernest-Ansermet 30, CH-1211 Geneva, Switzerland
| |
Collapse
|
9
|
Rüütel A, Yrjänä V, Kadam SA, Saar I, Ilisson M, Darnell A, Haav K, Haljasorg T, Toom L, Bobacka J, Leito I. Design, synthesis and application of carbazole macrocycles in anion sensors. Beilstein J Org Chem 2020; 16:1901-1914. [PMID: 32802207 PMCID: PMC7418101 DOI: 10.3762/bjoc.16.157] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2020] [Accepted: 07/16/2020] [Indexed: 11/23/2022] Open
Abstract
Carboxylate sensing solid-contact ion-selective electrodes (ISEs) were created to provide a proof-of-concept ISE development process covering all aspects from in silico ionophore design to functional sensor characterization. The biscarbazolylurea moiety was used to synthesize methylene-bridged macrocycles of different ring size aiming to fine tune selectivity towards different carboxylates. Cyclization was achieved with two separate strategies, using either amide synthesis to access up to –[CH2]10– macrocycles or acyl halides to access up to –[CH2]14– macrocycles. Seventy-five receptor–anion complexes were modelled and studied with COSMO-RS, in addition to all free host molecules. In order to predict initial selectivity towards carboxylates, 1H NMR relative titrations were used to quantify binding in DMSO-d6/H2O solvent systems of two proportions – 99.5%:0.5% m/m and 90.0%:10.0% m/m, suggesting initial selectivity towards acetate. Three ionophores were selected for successful sensor prototype development and characterization. The constructed ion-selective electrodes showed higher selectivity towards benzoate than acetate, i.e., the selectivity patterns of the final sensors deviated from that predicted by the classic titration experiments. While the binding constants obtained by NMR titration in DMSO-d6/H2O solvent systems provided important guidance for sensor development, the results obtained in this work emphasize the importance of evaluating the binding behavior of receptors in real sensor membranes.
Collapse
Affiliation(s)
- Alo Rüütel
- Institute of Chemistry, University of Tartu, Ravila 14a, 50411 Tartu, Estonia, https://analytical.chem.ut.ee
| | - Ville Yrjänä
- Johan Gadolin Process Chemistry Centre, Laboratory of Molecular Science and Engineering, Åbo Akademi University, Biskopsgatan 8, FI-20500 Turku/Åbo, Finland
| | - Sandip A Kadam
- Institute of Chemistry, University of Tartu, Ravila 14a, 50411 Tartu, Estonia, https://analytical.chem.ut.ee
| | - Indrek Saar
- Institute of Chemistry, University of Tartu, Ravila 14a, 50411 Tartu, Estonia, https://analytical.chem.ut.ee
| | - Mihkel Ilisson
- Institute of Chemistry, University of Tartu, Ravila 14a, 50411 Tartu, Estonia, https://analytical.chem.ut.ee
| | - Astrid Darnell
- Institute of Chemistry, University of Tartu, Ravila 14a, 50411 Tartu, Estonia, https://analytical.chem.ut.ee
| | - Kristjan Haav
- Institute of Chemistry, University of Tartu, Ravila 14a, 50411 Tartu, Estonia, https://analytical.chem.ut.ee
| | - Tõiv Haljasorg
- Institute of Chemistry, University of Tartu, Ravila 14a, 50411 Tartu, Estonia, https://analytical.chem.ut.ee
| | - Lauri Toom
- Institute of Chemistry, University of Tartu, Ravila 14a, 50411 Tartu, Estonia, https://analytical.chem.ut.ee
| | - Johan Bobacka
- Johan Gadolin Process Chemistry Centre, Laboratory of Molecular Science and Engineering, Åbo Akademi University, Biskopsgatan 8, FI-20500 Turku/Åbo, Finland
| | - Ivo Leito
- Institute of Chemistry, University of Tartu, Ravila 14a, 50411 Tartu, Estonia, https://analytical.chem.ut.ee
| |
Collapse
|
10
|
Tshepelevitsh S, Kadam SA, Darnell A, Bobacka J, Rüütel A, Haljasorg T, Leito I. LogP determination for highly lipophilic hydrogen-bonding anion receptor molecules. Anal Chim Acta 2020; 1132:123-133. [PMID: 32980103 DOI: 10.1016/j.aca.2020.07.024] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2020] [Revised: 07/10/2020] [Accepted: 07/13/2020] [Indexed: 01/31/2023]
Abstract
Lipophilicity, usually expressed as octanol-water partition coefficient (logPo/w), is an important property in biomedical research, drug design and technology. However, high logPo/w values of complex hydrogen-bonding molecules are not easy to measure or calculate. Exemplary problematic molecules are prospective active components (ionophores) of polymeric sensor membranes - the working elements of ion-selective electrodes. High lipophilicities of the membrane components are crucial for the sensor lifetime. In this work, lipophilicities of a wide range of urea-, carbazole- and indolocarbazole-based anion receptor molecules (some newly synthesized) and two common plasticizers were determined using a chromatography-based approach and/or the COSMO-RS method. Very high logPo/w values, up to around 20, i.e. far beyond directly experimentally accessible range, were obtained. The agreement between the two approaches ranged from very good to satisfactory. Based on these results, simple fragment-based equations were developed for quick lipophilicity estimation without any specialized software. Membrane-water partition coefficients for the studied compounds were modeled. Limitations and biases of the used methods are discussed.
Collapse
Affiliation(s)
- Sofja Tshepelevitsh
- Institute of Chemistry, University of Tartu, Ravila 14a, 50411, Tartu, Estonia
| | - Sandip A Kadam
- Institute of Chemistry, University of Tartu, Ravila 14a, 50411, Tartu, Estonia
| | - Astrid Darnell
- Institute of Chemistry, University of Tartu, Ravila 14a, 50411, Tartu, Estonia
| | - Johan Bobacka
- Åbo Akademi University, Johan Gadolin Process Chemistry Centre, Laboratory of Molecular Science and Engineering, Biskopsgatan 8, FI-20500, Turku/Åbo, Finland
| | - Alo Rüütel
- Institute of Chemistry, University of Tartu, Ravila 14a, 50411, Tartu, Estonia
| | - Tõiv Haljasorg
- Institute of Chemistry, University of Tartu, Ravila 14a, 50411, Tartu, Estonia
| | - Ivo Leito
- Institute of Chemistry, University of Tartu, Ravila 14a, 50411, Tartu, Estonia.
| |
Collapse
|
11
|
Abstract
Anions play a vital role in a broad range of environmental, technological, and physiological processes, making their detection/quantification valuable. Electroanalytical sensors offer much to the selective, sensitive, cheap, portable, and real-time analysis of anion presence where suitable combinations of selective (noncovalent) recognition and transduction can be integrated. Spurred on by significant developments in anion supramolecular chemistry, electrochemical anion sensing has received considerable attention in the past two decades. In this review, we provide a detailed overview of all electroanalytical techniques that have been used for this purpose, including voltammetric, impedimetric, capacititive, and potentiometric methods. We will confine our discussion to sensors that are based on synthetic anion receptors with a specific focus on reversible, noncovalent interactions, in particular, hydrogen- and halogen-bonding. Apart from their sensory properties, we will also discuss how electrochemical techniques can be used to study anion recognition processes (e.g., binding constant determination) and will furthermore provide a detailed outlook over future efforts and promising new avenues in this field.
Collapse
Affiliation(s)
- Robert Hein
- Department of Chemistry , University of Oxford , South Parks Road , Oxford OX1 3QZ , U.K
| | - Paul D Beer
- Department of Chemistry , University of Oxford , South Parks Road , Oxford OX1 3QZ , U.K
| | - Jason J Davis
- Department of Chemistry , University of Oxford , South Parks Road , Oxford OX1 3QZ , U.K
| |
Collapse
|