1
|
Zhang C, Kong J, Wu D, Guan Z, Ding B, Chen F. Wearable Sensor: An Emerging Data Collection Tool for Plant Phenotyping. PLANT PHENOMICS (WASHINGTON, D.C.) 2023; 5:0051. [PMID: 37408737 PMCID: PMC10318905 DOI: 10.34133/plantphenomics.0051] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 04/24/2023] [Accepted: 06/09/2023] [Indexed: 07/07/2023]
Abstract
The advancement of plant phenomics by using optical imaging-based phenotyping techniques has markedly improved breeding and crop management. However, there remains a challenge in increasing the spatial resolution and accuracy due to their noncontact measurement mode. Wearable sensors, an emerging data collection tool, present a promising solution to address these challenges. By using a contact measurement mode, wearable sensors enable in-situ monitoring of plant phenotypes and their surrounding environments. Although a few pioneering works have been reported in monitoring plant growth and microclimate, the utilization of wearable sensors in plant phenotyping has yet reach its full potential. This review aims to systematically examine the progress of wearable sensors in monitoring plant phenotypes and the environment from an interdisciplinary perspective, including materials science, signal communication, manufacturing technology, and plant physiology. Additionally, this review discusses the challenges and future directions of wearable sensors in the field of plant phenotyping.
Collapse
Affiliation(s)
- Cheng Zhang
- College of Engineering,
Nanjing Agricultural University, Nanjing 210095, China
- State Key Laboratory of Crop Genetics & Germplasm Enhancement and Utilization, Key Laboratory of Biology of Ornamental Plants in East China, National Forestry and Grassland Administration, College of Horticulture,
Nanjing Agricultural University, Nanjing 210095, China
- Zhongshan Biological Breeding Laboratory, No.50 Zhongling Street, Nanjing 210014, China
| | - Jingjing Kong
- College of Engineering,
Nanjing Agricultural University, Nanjing 210095, China
| | - Daosheng Wu
- College of Engineering,
Nanjing Agricultural University, Nanjing 210095, China
| | - Zhiyong Guan
- State Key Laboratory of Crop Genetics & Germplasm Enhancement and Utilization, Key Laboratory of Biology of Ornamental Plants in East China, National Forestry and Grassland Administration, College of Horticulture,
Nanjing Agricultural University, Nanjing 210095, China
- Zhongshan Biological Breeding Laboratory, No.50 Zhongling Street, Nanjing 210014, China
| | - Baoqing Ding
- State Key Laboratory of Crop Genetics & Germplasm Enhancement and Utilization, Key Laboratory of Biology of Ornamental Plants in East China, National Forestry and Grassland Administration, College of Horticulture,
Nanjing Agricultural University, Nanjing 210095, China
- Zhongshan Biological Breeding Laboratory, No.50 Zhongling Street, Nanjing 210014, China
| | - Fadi Chen
- State Key Laboratory of Crop Genetics & Germplasm Enhancement and Utilization, Key Laboratory of Biology of Ornamental Plants in East China, National Forestry and Grassland Administration, College of Horticulture,
Nanjing Agricultural University, Nanjing 210095, China
- Zhongshan Biological Breeding Laboratory, No.50 Zhongling Street, Nanjing 210014, China
| |
Collapse
|
2
|
Irkham, Nasa K, Kurnia I, Hartati YW, Einaga Y. Low-interference norepinephrine signal on dopamine detection using nafion-coated boron doped diamond electrodes. Biosens Bioelectron 2022; 220:114892. [DOI: 10.1016/j.bios.2022.114892] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2022] [Revised: 10/23/2022] [Accepted: 11/04/2022] [Indexed: 11/11/2022]
|
3
|
Triana Y, Ogata G, Tomisaki M, Irkham, Einaga Y. Blood Oxygen Sensor Using a Boron-Doped Diamond Electrode. Anal Chem 2022; 94:3948-3955. [PMID: 35192326 DOI: 10.1021/acs.analchem.1c04999] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
The electrochemical behavior of oxygen (O2) in blood was studied using boron-doped diamond (BDD) electrodes. Cyclic voltammogram of O2 in a 0.1 M phosphate buffer solution solution containing 1 × 10-6 M of bovine hemoglobin exhibits a reduction peak at -1.4 V (vs Ag/AgCl). Moreover, the scan rate dependence was investigated to study the reduction reaction mechanism, which was attributable to the reduction of O2 to H2O2 via two electrons. A linear calibration curve was observed in the concentration range of 86.88-314.63 mg L-1 (R2 = 0.99) with a detection limit of 1.0 mg L-1 (S/B = 3). The analytical performance was better than those with glassy carbon or platinum electrodes as the working electrode. In addition, an application to bovine blood was performed. The O2 concentration in the blood measured on the BDD electrodes was compared to that measured using an OxyLite Pro fiber-optic oxygen sensor device. Both methods gave similar values of the O2 concentration in the range of ∼40 to 150 mmHg. This result confirms that BDD electrodes could potentially be used to detect the O2 concentration in blood.
Collapse
Affiliation(s)
- Yunita Triana
- Department of Chemistry, Keio University, 3-14-1 Hiyoshi, Yokohama 2238522, Japan.,Department of Materials and Metallurgical Engineering, Institut Teknologi Kalimantan, Balikpapan 76127, Indonesia
| | - Genki Ogata
- Department of Chemistry, Keio University, 3-14-1 Hiyoshi, Yokohama 2238522, Japan
| | - Mai Tomisaki
- Department of Chemistry, Keio University, 3-14-1 Hiyoshi, Yokohama 2238522, Japan
| | - Irkham
- Department of Chemistry, Universitas Padjadjaran, Sumedang 45363, Indonesia
| | - Yasuaki Einaga
- Department of Chemistry, Keio University, 3-14-1 Hiyoshi, Yokohama 2238522, Japan
| |
Collapse
|
4
|
Shellaiah M, Sun KW. Diamond-Based Electrodes for Detection of Metal Ions and Anions. NANOMATERIALS 2021; 12:nano12010064. [PMID: 35010014 PMCID: PMC8746347 DOI: 10.3390/nano12010064] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/14/2021] [Revised: 12/14/2021] [Accepted: 12/22/2021] [Indexed: 02/07/2023]
Abstract
Diamond electrodes have long been a well-known candidate in electrochemical analyte detection. Nano- and micro-level modifications on the diamond electrodes can lead to diverse analytical applications. Doping of crystalline diamond allows the fabrication of suitable electrodes towards specific analyte monitoring. In particular, boron-doped diamond (BDD) electrodes have been reported for metal ions, anions, biomolecules, drugs, beverage hazards, pesticides, organic molecules, dyes, growth stimulant, etc., with exceptional performance in discriminations. Therefore, numerous reviews on the diamond electrode-based sensory utilities towards the specified analyte quantifications were published by many researchers. However, reviews on the nanodiamond-based electrodes for metal ions and anions are still not readily available nowadays. To advance the development of diamond electrodes towards the detection of diverse metal ions and anions, it is essential to provide clear and focused information on the diamond electrode synthesis, structure, and electrical properties. This review provides indispensable information on the diamond-based electrodes towards the determination of metal ions and anions.
Collapse
|