1
|
Nevídalová H, Michalcová L, Glatz Z. Capillary electrophoresis-based immunoassay and aptamer assay: A review. Electrophoresis 2020; 41:414-433. [PMID: 31975407 DOI: 10.1002/elps.201900426] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2019] [Revised: 01/14/2020] [Accepted: 01/15/2020] [Indexed: 12/31/2022]
Abstract
Over the last two decades, the group of techniques called affinity probe CE has been widely used for the detection and the determination of several types of biomolecules with high sensitivity. These techniques combine the low sample consumption and high separation power of CE with the selectivity of the probe to the target molecule. The assays can be defined according to the type of probe used: CE immunoassays, with an antibody as the probe, or aptamer-based CE, with an aptamer as the probe. Immunoassays are generally divided into homogeneous and heterogeneous groups, and homogeneous variant can be further performed in competitive or noncompetitive formats. Interacting partners are free in solution at homogeneous assay, as opposed to heterogeneous analyses, where one of them is immobilized onto a solid support. Highly sensitive fluorescence, chemiluminescence or electrochemical detections were typically used in this type of study. The use of the aptamers as probes has several advantages over antibodies such as shorter generation time, higher thermal stability, lower price, and lower variability. The aptamer-based CE technique was in practice utilized for the determination of proteins in biological fluids and environmentally or clinically important small molecules. Both techniques were also transferred to microchip. This review is focused on theoretical principles of these techniques and a summary of their applications in research.
Collapse
Affiliation(s)
- Hana Nevídalová
- Department of Biochemistry, Faculty of Science, Masaryk University, Brno, Czech Republic
| | - Lenka Michalcová
- Department of Biochemistry, Faculty of Science, Masaryk University, Brno, Czech Republic
| | - Zdeněk Glatz
- Department of Biochemistry, Faculty of Science, Masaryk University, Brno, Czech Republic
| |
Collapse
|
2
|
Moser AC, Willicott CW, Hage DS. Clinical applications of capillary electrophoresis based immunoassays. Electrophoresis 2014; 35:937-55. [PMID: 24132682 PMCID: PMC3975666 DOI: 10.1002/elps.201300421] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2013] [Revised: 09/27/2013] [Accepted: 10/03/2013] [Indexed: 12/17/2022]
Abstract
Immunoassays have long been an important set of tools in clinical laboratories for the detection, diagnosis, and treatment of disease. Over the last two decades, there has been growing interest in utilizing CE as a means for conducting immunoassays with clinical samples. The resulting method is known as a CE immunoassay. This approach makes use of the selective and strong binding of antibodies for their targets, as is employed in a traditional immunoassay, and combines this with the speed, efficiency, and small sample requirements of CE. This review discusses the variety of ways in which CE immunoassays have been employed with clinical samples. An overview of the formats and detection modes that have been employed in these applications is first presented. A more detailed discussion is then given on the type of clinical targets and samples that have been measured or studied by using CE immunoassays. Particular attention is given to the use of this method in the fields of endocrinology, pharmaceutical measurements, protein and peptide analysis, immunology, infectious disease detection, and oncology. Representative applications in each of these areas are described, with these examples involving work with both traditional and microanalytical CE systems.
Collapse
Affiliation(s)
| | | | - David S. Hage
- Chemistry Department, University of Nebraska, Lincoln, NE
| |
Collapse
|
3
|
Determination of methamphetamine, amphetamine and ecstasy by inside-needle adsorption trap based on molecularly imprinted polymer followed by GC-FID determination. Mikrochim Acta 2012. [DOI: 10.1007/s00604-012-0879-1] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
4
|
Reschke BR, Schiffbauer J, Edwards BF, Timperman AT. Simultaneous separation and detection of cations and anions on a microfluidic device with suppressed electroosmotic flow and a single injection point. Analyst 2010; 135:1351-9. [DOI: 10.1039/b921914e] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
5
|
Moser AC, Hage DS. Capillary electrophoresis-based immunoassays: principles and quantitative applications. Electrophoresis 2008; 29:3279-95. [PMID: 18646279 DOI: 10.1002/elps.200700871] [Citation(s) in RCA: 49] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
The use of CE as a tool to conduct immunoassays has been an area of increasing interest over the last decade. This approach combines the efficiency, small sample requirements, and relatively high speed of CE with the selectivity of antibodies as binding agents. This review examines the various assay formats and detection modes that have been reported for these assays, along with some representative applications. Most CE immunoassays in the past have employed homogeneous methods in which the sample and reagents are allowed to react in solution. These homogeneous methods have been conducted as both competitive binding immunoassays and as noncompetitive binding immunoassays. Fluorescent labels are most commonly used for detection in these assays, but enzyme labels have also been utilized for such work. Some additional work has been performed in CE immunoassays with heterogeneous methods in which either antibodies or an analog of the analyte is immobilized to a solid support. These heterogeneous methods can be used for the selective isolation of analytes prior to their separation by CE or to remove a given species from a sample/reagent mixture prior to analysis by CE. These CE immunoassays can be used with a variety of detection modes, such as fluorescence, UV/Vis absorbance, chemiluminescence, electrochemical measurements, MS, and surface plasmon resonance.
Collapse
Affiliation(s)
- Annette C Moser
- Chemistry Department, University of Nebraska, Kearney, NE, USA
| | | |
Collapse
|
6
|
Sun J, Xu X, Wang C, You T. Analysis of amphetamines in urine with liquid-liquid extraction by capillary electrophoresis with simultaneous electrochemical and electrochemiluminescence detection. Electrophoresis 2008; 29:3999-4007. [DOI: 10.1002/elps.200700875] [Citation(s) in RCA: 46] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
7
|
Kumazawa T, Hasegawa C, Lee XP, Hara K, Seno H, Suzuki O, Sato K. Simultaneous determination of methamphetamine and amphetamine in human urine using pipette tip solid-phase extraction and gas chromatography–mass spectrometry. J Pharm Biomed Anal 2007; 44:602-7. [PMID: 17267160 DOI: 10.1016/j.jpba.2006.12.025] [Citation(s) in RCA: 82] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2006] [Revised: 12/19/2006] [Accepted: 12/24/2006] [Indexed: 11/19/2022]
Abstract
Methamphetamine and amphetamine were extracted from human urine samples using pipette tip solid-phase extraction (SPE) with MonoTip C18 tips (pipette tip volume, 200 microl), in which C18-bonded monolithic silica gel was fixed. A sample of human urine (0.5 ml) containing methamphetamine, amphetamine, and N-methylbenzylamine as internal standard (IS), was mixed with 25 microl of 1M sodium hydroxide solution. The mixture was extracted into the C18 phase of the SPE tip by 25 repeated aspirating/dispensing cycles using a manual micropipettor. Analytes retained in the C18 phase were then eluted with methanol by five repeated aspirating/dispensing cycles. After derivatization with trifluoroacetic anhydride, analytes were measured by gas chromatography/mass spectrometry with selected ion monitoring in the positive-ion electron impact mode. Recoveries of methamphetamine, amphetamine, and IS spiked into urine were more than 82.9, 82.2, and 78.2%, respectively. Regression equations for methamphetamine and amphetamine showed excellent linearity in the range of 0.25-200 ng/0.5 ml. Limit of detection was 0.04 ng/0.5 ml for methamphetamine and 0.05 ng/0.5 ml for amphetamine. Intra- and inter-day coefficients of variations for both stimulants were not greater than 10.8%. The data obtained from actual determination of methamphetamine and amphetamine in autopsy urine samples are also presented for validation of the method.
Collapse
Affiliation(s)
- Takeshi Kumazawa
- Department of Legal Medicine, Showa University School of Medicine, 1-5-8 Hatanodai, Tokyo 142-8555, Japan.
| | | | | | | | | | | | | |
Collapse
|
8
|
Cheng HL, Jong YJ, Li JH, Ko WK, Wu SM. Cation-selective exhaustive injection and sweeping MEKC for direct analysis of methamphetamine and its metabolites in urine. Electrophoresis 2007; 27:4711-6. [PMID: 17080473 DOI: 10.1002/elps.200600174] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Direct analysis of methamphetamine, amphetamine, and p-hydroxymethamphetamine in urine was achieved by cation-selective exhaustive injection and sweeping micellar EKC. A bare fused-silica capillary (40 cm, 50 microm id) was filled with phosphate buffer (80 mM, pH 3, containing 20% ACN). Then a high-conductivity buffer (100 mM phosphate, pH 3; 6.9 kPa for 2.5 min) was injected. Samples were loaded using electrokinetic injection (10 kV, 600 s) which created long zones of cationic analytes. To enhance sensitivity by sweeping, the stacking step was performed using a phosphate buffer (50 mM, pH 3, containing 20% ACN and 100 mM SDS) at -20 kV before separation by MEKC. This method was capable of detecting the analytes at ppb levels. The calibration plots were linear (r(2) >or= 0.9948) over a range of 100-5000 ng/mL for methamphetamine, and 100-2000 ng/mL for amphetamine and p-hydroxymethamphetamine. The LODs (S/N = 3) were 20 ng/mL for methamphetamine, and 15 ng/mL for amphetamine and p-hydroxymethamphetamine. The method was applied to analysis of 14 urine samples of addicts and is suitable for screening suspected samples for forensic purposes. The results showed good agreement with fluorescence polarization immunoassay and GC-MS.
Collapse
Affiliation(s)
- Hui-Ling Cheng
- Graduate Institute of Pharmaceutical Science, College of Pharmacy, Kaohsiung Medical University, Kaohsiung, Taiwan
| | | | | | | | | |
Collapse
|
9
|
Abstract
This paper reviews immunoaffinity CE procedures developed since 1998 for drug, hormone, and disease marker analyses of body fluids and tissues. Immunoaffinity CE and related techniques are described. Examples of clinical applications are included.
Collapse
Affiliation(s)
- Lotta K Amundsen
- Technical Research Centre of Finland (VTT), P.O. Box 1000, FIN-02044 VTT, Finland
| | | |
Collapse
|
10
|
Jabeen R, Payne D, Wiktorowicz J, Mohammad A, Petersen J. Capillary electrophoresis and the clinical laboratory. Electrophoresis 2006; 27:2413-38. [PMID: 16718719 DOI: 10.1002/elps.200500948] [Citation(s) in RCA: 52] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
Abstract
Over the past 15 years, CE as an analytical tool has shown great promise in replacing many conventional clinical laboratory methods, such as electrophoresis and HPLC. CE's appeal was that it was fast, used very small amounts of sample and reagents, was extremely versatile, and was able to separate large and small analytes, whether neutral or charged. Because of this versatility, numerous methods have been developed for analytes that are of clinical interest. Other than molecular diagnostic and forensic laboratories CE has not been able to make a major impact in the United States. In contrast, in Europe and Japan an increasing number of clinical laboratories are using CE. Now that automated multicapillary instruments are commercially available along with cost-effective test kits, CE may yet be accepted as an instrument that will be routinely used in the clinical laboratories. This review will focus on areas where CE has the potential to have the greatest impact on the clinical laboratory. These include analyses of proteins found in serum and urine, hemoglobin (A1c and variants), carbohydrate-deficient transferrin, forensic and therapeutic drug screening, and molecular diagnostics.
Collapse
Affiliation(s)
- Rukhsana Jabeen
- University of Texas Medical Branch--Pathology, Galveston, TX 77555-0551, USA
| | | | | | | | | |
Collapse
|
11
|
|
12
|
Yeung WSB, Luo GA, Wang QG, Ou JP. Capillary electrophoresis-based immunoassay. J Chromatogr B Analyt Technol Biomed Life Sci 2004; 797:217-28. [PMID: 14630151 DOI: 10.1016/s1570-0232(03)00489-6] [Citation(s) in RCA: 47] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Capillary electrophoresis-based immunoassay (CEIA) is a developing analytical technique with a number of advantages over conventional immunoassay, such as reduced sample consumption, simpler procedure, easy simultaneous determination of multiple analytes, and short analysis time. However, there are still a number of technical issues that researchers on CEIA have to solve before the assay can be more widely used. These issues include method to improve the concentration sensitivity of the assay, requirement for robust separation strategy for different analytes, and method to increase the throughput of the assay. The approaches to solve these issues are reviewed. Several studies have been devoted to develop general separation strategies for CEIA, and to enhance the sensitivity of detection. The recent development of microchip-based CEIA is encouraging and is likely to address more drawbacks of CEIA, particularly on the throughput issue.
Collapse
Affiliation(s)
- W S B Yeung
- Department of Obstetrics and Gynaecology, The University of Hong Kong, Queen Mary Hospital, Pokfulam Road, Hong Kong, PR China.
| | | | | | | |
Collapse
|
13
|
Heegaard NHH, Kennedy RT. Antigen-antibody interactions in capillary electrophoresis. J Chromatogr B Analyt Technol Biomed Life Sci 2002; 768:93-103. [PMID: 11939562 DOI: 10.1016/s0378-4347(01)00489-3] [Citation(s) in RCA: 47] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
Immunoreactions in combination with separations by capillary electrophoresis (CE) are increasingly being used to quantitate specific analytes in biological fluids. Both competitive and non-competitive approaches have been used for the purpose and, in selected cases, now compare favorably with conventional quantitative immunoassays with respect to concentration limits of detection. CE is also a useful method to evaluate antigen-antibody binding on-line and offers unique possibilities for binding constant estimates, also for weakly binding antibodies and antibody fragments. In this review we cover recent developments in the use of antigen-antibody interactions in conjunction with CE and conclude that continued development of miniaturization, on-line preconcentration and more sensitive detection schemes will contribute to the further dissemination of CE-based immunoassays building on already established affinity CE approaches.
Collapse
Affiliation(s)
- Niels H H Heegaard
- Department of Autoimmunology, Statens Serum Institute, Copenhagen, Denmark.
| | | |
Collapse
|
14
|
Zaugg S, Zhang X, Sweedler J, Thormann W. Determination of salicylate, gentisic acid and salicyluric acid in human urine by capillary electrophoresis with laser-induced fluorescence detection. JOURNAL OF CHROMATOGRAPHY. B, BIOMEDICAL SCIENCES AND APPLICATIONS 2001; 752:17-31. [PMID: 11254191 DOI: 10.1016/s0378-4347(00)00507-7] [Citation(s) in RCA: 52] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Acetylsalicylic acid (Aspirin) is rapidly metabolized to salicylic acid (salicylate) and other compounds, including gentisic acid and salicyluric acid. Monitoring of salicylate and its metabolites is of toxicological, pharmacological and biomedical interest. Three capillary electrophoresis (CE) methods featuring alkaline aqueous buffers, laser-induced fluorescence (LIF) detection and no solute extraction or derivatization have been explored. A competitive binding, electrokinetic capillary-based immunoassay is developed that recognizes the presence of salicylate and gentisic acid in urine. Differentiation of the two compounds, however, is problematic. With appropriate ultraviolet excitation, many salicylate-related compounds are fluorescent so that CE with direct urine injection and LIF detection permits the determination of salicylate, gentisic acid and salicyluric acid. Using a HeCd laser with 325 nm produces interference-free monitoring of all three compounds. Using 257 nm excitation from a frequency doubled Ar ion laser, native fluorescence of an endogenous urinary compound that co-migrates with gentisic acid is observed. With wavelength-resolved fluorescence detection, however, the two substances are distinguished. Furthermore, this technique, with comparison to literature data, permits the putative assignment of several peaks to other salicylate metabolites, namely glucuronide conjugates of salicylate and salicyluric acid. All three CE-LIF techniques have been applied to toxicological patient urines and urines collected after ingestion of 500 mg acetylsalicylic acid. CE results compare favorably with those obtained by a commercial fluorescence polarization immunoassay and by a conventional photometric assay.
Collapse
Affiliation(s)
- S Zaugg
- Department of Clinical Pharmacology, University of Bern, Switzerland
| | | | | | | |
Collapse
|
15
|
Abstract
This review covers the progress and developments in the field of capillary electrophoresis immunoassay (CEIA) over the past three years. Because many excellent descriptions of the principles of these methods are available (e.g., in the reviews listed in this article), no elementary introduction is given to the field of immunoassays (IAs) or CEIAs. This report focuses exclusively on experimental results, dividing the CEIA papers into the categories of direct, indirect, and microchip electrophoretic immunoassays. In the last section, a brief summary of the current status of the CEIA field is presented.
Collapse
Affiliation(s)
- D Schmalzing
- Whitehead Institute for Biomedical Research, Cambridge, MA 02142, USA.
| | | | | |
Collapse
|
16
|
Pedersen-Bjergaard S, Rasmussen KE, Halvorsen TG. Liquid-liquid extraction procedures for sample enrichment in capillary zone electrophoresis. J Chromatogr A 2000; 902:91-105. [PMID: 11192163 DOI: 10.1016/s0021-9673(00)00738-x] [Citation(s) in RCA: 105] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
This review article presents an overview of applications of liquid-liquid extraction (LLE) for analyte enrichment and clean-up of samples prior to capillary zone electrophoresis (CZE). The basic principles of LLE are discussed with special emphasis on analyte enrichment. In addition, attention is focused on the requirements for the final extract to be compatible with CZE. The paper discusses selected examples from the literature with special emphasis on detection limits in drug analysis and in environmental chemistry. Finally, the paper focus on alternative liquid-phase extraction concepts based on electroextraction, supported liquid membranes, and liquid-phase microextraction.
Collapse
|
17
|
Wey AB, Caslavska J, Thormann W. Analysis of codeine, dihydrocodeine and their glucuronides in human urine by electrokinetic capillary immunoassays and capillary electrophoresis-ion trap mass spectrometry. J Chromatogr A 2000; 895:133-46. [PMID: 11105855 DOI: 10.1016/s0021-9673(00)00636-1] [Citation(s) in RCA: 44] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
Screening for and confirmation of illicit, abused and banned drugs in human urine is a timely topic in which capillary separation techniques play a key role. Capillary electrophoresis (CE) represents the newest technology employed in this field of analysis. Two rapid competitive binding, electrokinetic capillary-based immunoassays are shown to be capable of recognizing the presence, but not the identity, of urinary opioids, namely codeine (COD), codeine-6-glucuronide, dihydrocodeine (DHC), dihydrocodeine-6-glucuronide, morphine (MOR), morphine-3-glucuronide and ethylmorphine (EMOR). In these approaches, aliquots of urine and immunoreagents of a commercial, broadly cross-reacting fluorescence polarization immunoassay for opiates were combined and analyzed by capillary zone electrophoresis or micellar electrokinetic capillary chromatography with laser induced fluorescence detection. With the fluorescent tracer solution employed, the former method is shown to provide simple electropherograms which are characterized by an opioid concentration dependent magnitude of the free tracer peak. In presence of dodecyl sulfate micelles, however, two tracer peaks with equal opioid concentration sensitivity are monitored. These data suggest the presence of two fluorescent tracers which react competitively with the urinary opioids for the binding sites of the antibody. Assay sensitivities for COD and MOR are comparable (10 ng/ml), whereas those for DHC and EMOR are about four-fold lower. Furthermore, glucuronides are shown to react like the corresponding free opioids. Analysis of urines that were collected after administration of 7 mg COD and 25 mg DHC tested positively in both assay formats. The presence of the free and conjugated codeinoids in these urines and their identification was accomplished by capillary electrophoresis-ion trap mass spectrometry (CE-MS). This confirmatory assay is based upon solid-phase extraction using a mixed-mode polymer cartridge followed by CE hyphenated to the LCQ mass spectrometer with electrospray ionization in the positive ion mode. With this technology, MS2 is employed for proper identification of COD (m/z 300.4) and DHC (m/z 302.4) whereas MS3 provides unambiguous identification of the glucuronides of COD (m/z 476.5) and DHC (m/z 478.5) via their fragmentation to COD and DHC, respectively. MSn (n > or = 2) is shown to be capable of properly identifying the urinary codeinoids on the 100-200 ng/ml concentration level.
Collapse
Affiliation(s)
- A B Wey
- Department of Clinical Pharmacology, University of Berne, Switzerland
| | | | | |
Collapse
|
18
|
Thormann W, Caslavska J, Ramseier A, Siethoff C. Multianalyte capillary electrophoresis assays for screening and confirmation of urinary drugs of abuse. ACTA ACUST UNITED AC 2000. [DOI: 10.1002/(sici)1520-667x(2000)12:1<13::aid-mcs3>3.0.co;2-3] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
|
19
|
Ramseier A, Siethoff C, Caslavska J, Thormann W. Confirmation testing of amphetamines and designer drugs in human urine by capillary electrophoresis-ion trap mass spectrometry. Electrophoresis 2000; 21:380-7. [PMID: 10675019 DOI: 10.1002/(sici)1522-2683(20000101)21:2<380::aid-elps380>3.0.co;2-l] [Citation(s) in RCA: 57] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Monitoring of amphetamines and designer drugs in human urine is a timely topic in clinical toxicology, surveillance of drug substitution, forensic science, drug testing at the workplace, and doping control. Confirmation testing of urinary amphetamine, methamphetamine, 3,4-methylenedioxymethamphetamine (MDMA, Ecstasy) and 3,4-methylenedioxyamphetamine (MDA) by capillary electrophoresis (CE) combined with atmospheric pressure electrospray ionization and ion trap mass spectrometry (MS) is described. Using an aqueous pH 4.6 buffer composed of ammonium acetate/acetic acid, CE-MS and CE-MS2 provided data that permitted the unambiguous confirmation of these drugs in external quality control urines. Furthermore, other drugs of abuse present in alkaline urinary extracts, including methadone and morphine, could also be monitored. The data presented illustrate that the sensitivity achieved with the benchtop MS is comparable to that observed by CE with UV absorption detection. CE-MS2 is further shown to be capable of identifying comigrating compounds, including the comigration of amphetamine with nicotine.
Collapse
Affiliation(s)
- A Ramseier
- Department of Clinical Pharmacology, University of Bern, Switzerland
| | | | | | | |
Collapse
|
20
|
Heegaard NH, Kennedy RT. Identification, quantitation, and characterization of biomolecules by capillary electrophoretic analysis of binding interactions. Electrophoresis 1999; 20:3122-33. [PMID: 10596820 DOI: 10.1002/(sici)1522-2683(19991001)20:15/16<3122::aid-elps3122>3.0.co;2-m] [Citation(s) in RCA: 110] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
The high resolving power of capillary electrophoresis combined with the specificity of binding interactions may be used with advantage to characterize the structure-function relationship of biomolecules, to quantitate specific analytes in complex sample matrices, and to determine the purity of pharmaceutical and other molecules. We here review recent and innovative methodologies and applications of high resolution affinity electrophoresis within the fields of binding constant determination, structure-activity studies, quantitative microassays, analysis of drug purity and protein conformation, and immobilized affinity ligands. Despite the virtues of these approaches with respect to applicability, resolving power, speed, and low sample consumption, problems remain with respect to analyte identification and low concentration limits of detection. The ongoing development of new detector technologies for capillary electrophoresis such as mass spectrometry, and possibly nuclear magnetic resonance and other spectroscopic methods, is therefore very promising for the continued increased use of affinity capillary electrophoresis.
Collapse
Affiliation(s)
- N H Heegaard
- Department of Autoimmunology, Statens Serum Institut, Copenhagen, Denmark.
| | | |
Collapse
|
21
|
Thormann W, Wey AB, Lurie IS, Gerber H, Byland C, Malik N, Hochmeister M, Gehrig C. Capillary electrophoresis in clinical and forensic analysis: recent advances and breakthrough to routine applications. Electrophoresis 1999; 20:3203-36. [PMID: 10596826 DOI: 10.1002/(sici)1522-2683(19991001)20:15/16<3203::aid-elps3203>3.0.co;2-e] [Citation(s) in RCA: 54] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
This paper is a comprehensive review article on capillary electrophoresis (CE) in clinical and forensic analysis. It is based upon the literature of 1997 and 1998, presents CE examples in major fields of application, and provides an overview of the key achievements encountered, including those associated with the analysis of drugs, serum proteins, hemoglobin variants, and nucleic acids. For CE in clinical and forensic analysis, the past two years witnessed a breakthrough to routine applications. As most coauthors of this review are associated with diagnostic or forensic laboratories now using CE on a routine basis, this review also contains data from routine applications in drug, protein, and DNA analysis. With the first-hand experience of providing analytical service under stringent quality control conditions, aspects of quality assurance, assay specifications for clinical and forensic CE and the pros and cons of this maturing, cost-and pollution-controlled age technology are also discussed.
Collapse
Affiliation(s)
- W Thormann
- Department of Clinical Pharmacology, University of Bern, Switzerland.
| | | | | | | | | | | | | | | |
Collapse
|
22
|
Ramseier A, Caslavska J, Thormann W. Stereoselective screening for and confirmation of urinary enantiomers of amphetamine, methamphetamine, designer drugs, methadone and selected metabolites by capillary electrophoresis. Electrophoresis 1999; 20:2726-38. [PMID: 10532341 DOI: 10.1002/(sici)1522-2683(19990901)20:13<2726::aid-elps2726>3.0.co;2-6] [Citation(s) in RCA: 44] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Data presented in this paper demonstrate that a competitive binding, electrokinetic capillary-based immunoassay previously used for screening of urinary amphetamine and analogs cannot be employed to distinguish between the enantiomers of amphetamine and methamphetamine. However, capillary zone electrophoresis with a pH 2.5 buffer containing (2-hydroxypropyl)-beta-cyclodextrin as chiral selector is shown to permit the enantioselective analysis of urinary extracts containing methamphetamine, amphetamine, 3,4-methylenedioxymethamphetamine (Ecstasy) and other designer drugs, and methadone together with its major metabolite, 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine. In that approach, enantiomer identification is based upon comparison of extracted polychrome UV absorption data and electropherograms obtained by rerunning of spiked extracts with spectra and electropherograms monitored after extraction of fortified blank urine. The suitability of the described chiral electrokinetic capillary method for drug screening and confirmation is demonstrated via analysis of unhydrolyzed quality control urines containing a variety of drugs of abuse. Furthermore, in a urine of a patient under selegiline pharmacotherapy, the presence of the R-(-)-enantiomers of methamphetamine and amphetamine could be unambiguously identified. Direct intake of an R-enantiomer or ingestion of drugs that metabolize to the R-enantiomers can be distinguished from the intake of S-(+)-enantiomers (drug abuse) or prescribed drugs that metabolize to the S-enantiomers of methamphetamine and amphetamine. The described approach is simple, reproducible, inexpensive and reliable (free of interferences of other major basic drugs that are frequently found in toxicological urines) and could thus be used for screening for and confirmation of urinary enantiomers in a routine laboratory.
Collapse
Affiliation(s)
- A Ramseier
- Department of Clinical Pharmacology, University of Bern, Switzerland
| | | | | |
Collapse
|
23
|
Caslavska J, Allemann D, Thormann W. Analysis of urinary drugs of abuse by a multianalyte capillary electrophoretic immunoassay. J Chromatogr A 1999; 838:197-211. [PMID: 10327639 DOI: 10.1016/s0021-9673(99)00115-6] [Citation(s) in RCA: 52] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
This paper characterizes a novel multianalyte competitive binding, electrokinetic capillary-based immunoassay for urinary methadone, opiates, benzoylecgonine (cocaine metabolite) and amphetamines. After incubation of 25 microliters urine with the reactants for several minutes in the presence of an internal standard, a small aliquot of the mixture is applied onto a fused-silica capillary and the unbound fluorescein labelled drug tracers are monitored by capillary electrophoresis with on-column laser induced fluorescence detection. The multianalyte assay is shown to be rapid, simple, quantitative, capable of recognizing urinary drug concentrations > or = 30 ng/ml and suitable for screening of patient urines. Data are demonstrated to compare well with those obtained by routine screening methods based on enzyme multiplied immunoassay techniques and fluorescence polarization immunoassays. The electrokinetic capillary assay has been validated via analysis of external quality control urines and confirmation analysis of patient urines using GC-MS.
Collapse
Affiliation(s)
- J Caslavska
- Department of Clinical Pharmacology, University of Bern, Switzerland
| | | | | |
Collapse
|