1
|
Kuzyk VO, Somsen GW, Haselberg R. CE-MS for Proteomics and Intact Protein Analysis. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2021; 1336:51-86. [PMID: 34628627 DOI: 10.1007/978-3-030-77252-9_4] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
This chapter aims to explore various parameters involved in achieving high-end capillary electrophoresis hyphenated to mass spectrometry (CE-MS) analysis of proteins, peptides, and their posttranslational modifications. The structure of the topics discussed in this book chapter is conveniently mapped on the scheme of the CE-MS system itself, starting from sample preconcentration and injection techniques and finishing with mass analyzer considerations. After going through the technical considerations, a variety of relevant applications for this analytical approach are presented, including posttranslational modifications analysis, clinical biomarker discovery, and its growing use in the biotechnological industry.
Collapse
Affiliation(s)
- Valeriia O Kuzyk
- Division of Bioanalytical Chemistry, AIMMS: Amsterdam Institute of Molecular and Life Sciences, Vrije Universiteit Amsterdam, Amsterdam, The Netherlands
| | - Govert W Somsen
- Division of Bioanalytical Chemistry, AIMMS: Amsterdam Institute of Molecular and Life Sciences, Vrije Universiteit Amsterdam, Amsterdam, The Netherlands
| | - Rob Haselberg
- Division of Bioanalytical Chemistry, AIMMS: Amsterdam Institute of Molecular and Life Sciences, Vrije Universiteit Amsterdam, Amsterdam, The Netherlands.
| |
Collapse
|
2
|
Han X, Wang Y, Aslanian A, Fonslow B, Graczyk B, Davis TN, Yates JR. In-line separation by capillary electrophoresis prior to analysis by top-down mass spectrometry enables sensitive characterization of protein complexes. J Proteome Res 2014; 13:6078-86. [PMID: 25382489 PMCID: PMC4262260 DOI: 10.1021/pr500971h] [Citation(s) in RCA: 51] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
![]()
Intact
protein analysis via top-down mass spectrometry (MS) provides
a bird’s eye view over the protein complexes and complex protein
mixtures with the unique capability of characterizing protein variants,
splice isoforms, and combinatorial post-translational modifications
(PTMs). Here we applied capillary electrophoresis (CE) through a sheathless
CE–electrospray ionization interface coupled to an LTQ Velos
Orbitrap Elite mass spectrometer to analyze the Dam1 complex from Saccharomyces cerevisiae. We achieved a 100-fold
increase in sensitivity compared to a reversed-phase liquid chromatography
coupled MS analysis of recombinant Dam1 complex with a total loading
of 2.5 ng (12 amol). N-terminal processing forms of individual subunits
of the Dam1 complex were observed as well as their phosphorylation
stoichiometry upon Mps1p kinase treatment.
Collapse
Affiliation(s)
- Xuemei Han
- Department of Chemical Physiology, The Scripps Research Institute , 10550 North Torrey Pines Road, La Jolla, California 92037, United States
| | | | | | | | | | | | | |
Collapse
|
3
|
Han X, Wang Y, Aslanian A, Bern M, Lavallée-Adam M, Yates JR. Sheathless capillary electrophoresis-tandem mass spectrometry for top-down characterization of Pyrococcus furiosus proteins on a proteome scale. Anal Chem 2014; 86:11006-12. [PMID: 25346219 PMCID: PMC4238646 DOI: 10.1021/ac503439n] [Citation(s) in RCA: 56] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/17/2023]
Abstract
![]()
Intact protein analysis via top-down
mass spectrometry (MS) provides
the unique capability of fully characterizing protein isoforms and
combinatorial post-translational modifications (PTMs) compared to
the bottom-up MS approach. Front-end protein separation poses a challenge
for analyzing complex mixtures of intact proteins on a proteomic scale.
Here we applied capillary electrophoresis (CE) through a sheathless
capillary electrophoresis-electrospray ionization (CESI) interface
coupled to an Orbitrap Elite mass spectrometer to profile the proteome
from Pyrococcus furiosus. CESI-top-down MS analysis
of Pyrococcus furiosus cell lysate identified 134
proteins and 291 proteoforms with a total sample consumption of 270
ng in 120 min of total analysis time. Truncations and various PTMs
were detected, including acetylation, disulfide bonds, oxidation,
glycosylation, and hypusine. This is the largest scale analysis of
intact proteins by CE-top-down MS to date.
Collapse
Affiliation(s)
- Xuemei Han
- Department of Chemical Physiology, The Scripps Research Institute , 10550 North Torrey Pines Road, La Jolla, California 92037, United States
| | | | | | | | | | | |
Collapse
|
4
|
Li Y, Compton PD, Tran JC, Ntai I, Kelleher NL. Optimizing capillary electrophoresis for top-down proteomics of 30-80 kDa proteins. Proteomics 2014; 14:1158-64. [PMID: 24596178 DOI: 10.1002/pmic.201300381] [Citation(s) in RCA: 66] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2013] [Revised: 01/08/2014] [Accepted: 02/27/2014] [Indexed: 01/01/2023]
Abstract
The direct analysis of intact proteins via MS offers compelling advantages in comparison to alternative methods due to the direct and unambiguous identification and characterization of protein sequences it provides. The inability to efficiently analyze proteins in the "middle mass range," defined here as proteins from 30 to 80 kDa, in a robust fashion has limited the adoption of these "top-down" methods. Largely, a result of poor liquid chromatographic performance, the limitations in this mass range may be addressed by alternative separations that replace chromatography. Herein, the short migration times of CZE-ESI-MS/MS have been extended to size-sorted whole proteins in complex mixtures from Pseudomonas aeruginosa PA01. An electrokinetically pumped nanospray interface, a coated capillary, and a stacking method for on-column sample concentration were developed to achieve high-loading capacity and separation resolution. We achieved full width at half maximum of 8-16 s for model proteins up to 29 kDa and identified 30 proteins in the mass range of 30-80 kDa from P. aeruginosa PA01 whole cell lysate. These results suggest that CZE-ESI-MS/MS is capable of identifying proteins in the middle mass range in top-down proteomics.
Collapse
Affiliation(s)
- Yihan Li
- Departments of Chemistry and Molecular Biosciences, Proteomics Center of Excellence, Northwestern University, Evanston, IL, USA
| | | | | | | | | |
Collapse
|
5
|
Catherman AD, Skinner OS, Kelleher NL. Top Down proteomics: facts and perspectives. Biochem Biophys Res Commun 2014; 445:683-93. [PMID: 24556311 PMCID: PMC4103433 DOI: 10.1016/j.bbrc.2014.02.041] [Citation(s) in RCA: 308] [Impact Index Per Article: 30.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2014] [Accepted: 02/10/2014] [Indexed: 12/29/2022]
Abstract
The rise of the "Top Down" method in the field of mass spectrometry-based proteomics has ushered in a new age of promise and challenge for the characterization and identification of proteins. Injecting intact proteins into the mass spectrometer allows for better characterization of post-translational modifications and avoids several of the serious "inference" problems associated with peptide-based proteomics. However, successful implementation of a Top Down approach to endogenous or other biologically relevant samples often requires the use of one or more forms of separation prior to mass spectrometric analysis, which have only begun to mature for whole protein MS. Recent advances in instrumentation have been used in conjunction with new ion fragmentation using photons and electrons that allow for better (and often complete) protein characterization on cases simply not tractable even just a few years ago. Finally, the use of native electrospray mass spectrometry has shown great promise for the identification and characterization of whole protein complexes in the 100 kDa to 1 MDa regime, with prospects for complete compositional analysis for endogenous protein assemblies a viable goal over the coming few years.
Collapse
Affiliation(s)
- Adam D Catherman
- Departments of Chemistry and Molecular Biosciences, The Chemistry of Life Processes Institute, The Proteomics Center of Excellence, The Robert H. Lurie Comprehensive Cancer Center, Northwestern University, Evanston, IL 60208, United States
| | - Owen S Skinner
- Departments of Chemistry and Molecular Biosciences, The Chemistry of Life Processes Institute, The Proteomics Center of Excellence, The Robert H. Lurie Comprehensive Cancer Center, Northwestern University, Evanston, IL 60208, United States
| | - Neil L Kelleher
- Departments of Chemistry and Molecular Biosciences, The Chemistry of Life Processes Institute, The Proteomics Center of Excellence, The Robert H. Lurie Comprehensive Cancer Center, Northwestern University, Evanston, IL 60208, United States.
| |
Collapse
|
6
|
Grimme J, King T, Dong Jo K, Cropek D, Timperman AT. Development of Fieldable Lab-on-a-Chip Systems for Detection of a Broad Array of Targets From Toxicants to Biowarfare Agents. J Nanotechnol Eng Med 2013. [DOI: 10.1115/1.4025539] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
Abstract
In today's world, there is an ever growing need for lightweight, portable sensor systems to detect chemical toxicants and biological toxins. The challenges encountered with such detection systems are numerous, as there are a myriad of potential targets in various sample matrices that are often present at trace-level concentrations. At ERDC-CERL, the Lab-on-a-Chip (LoaC) group is working with a number of academic and small business collaborators to develop solutions to meet these challenges. This report will focus on recent advances in three distinct areas: (1) the development of a flexible platform to allow fieldable LoaC analyses of water samples, (2) cell-, organelle-, and synthetic biology-based toxicity sensors, and (3) nanofluidic/microfluidic interface (NMI) sample enrichment devices. To transition LoaC-based sensors from the laboratory bench to the field, a portable hardware system capable of operating a wide variety of microfluidic chip-based assays has been developed. As a demonstration of the versatility of this approach assays for the separation and quantitation of anionic contaminants (i.e., perchlorate), quantitation of heavy metals (Pb and Cd), and cell-based toxicity sensors have been developed and demonstrated. Sensors harboring living cells provide a rapid means of assessing water toxicity. Cell-based sensors exploit the sensitivity of a living cell to discrete changes in its environment to report the presence of toxicants. However, this sensitivity of cells to environmental changes also hinders their usability in nonlaboratory settings. Therefore, isolating intact organelles (i.e., mitochondria) offers a nonliving alternative that preserves the sensitivity of the living cells and allows the electrochemical reporting of the presence of a contaminant. Pursuing a synthetic biology approach has also allowed the development of nonliving reporting mechanisms that utilize engineered biological pathways for novel sensing and remediation applications. To help overcome the challenges associated with the detection of target species at trace-level concentrations, NMIs are being developed for the enrichment of charged species in solution. NMI concentrators can be classified as either electroosmotic flow or electrophoresis-dominant devices. Further advances in electrophoresis-dominant concentrators will aid in the analysis of samples that contain proteins and other substances prone to surface adsorption. These recent advances illustrate how LoaC systems provide a suitable platform for development of fieldable sensors to detect a broad range of chemical/biological pollutants and threats.
Collapse
Affiliation(s)
| | | | | | | | - Aaron T. Timperman
- U.S. Army Engineer Research and Development Center, Construction Engineering Research Lab (ERDC-CERL), Champaign, IL 61826
| |
Collapse
|
7
|
Moini M. High-throughput capillary electrophoresis-mass spectrometry: from analysis of amino acids to analysis of protein complexes. Methods Mol Biol 2013; 984:79-119. [PMID: 23386339 DOI: 10.1007/978-1-62703-296-4_8] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
Recent advances in capillary electrophoresis-mass spectrometry (CE-MS) interfacing using porous tip is leading to commercialization of CE-MS with a sheathless interface for the first time. The new sheathless interface in conjunction with CE capillary coatings using self-coating background electrolytes (BGE) has significantly simplified CE-MS analysis of complex mixtures. CE-MS, with its high separation efficiency, compound identification capability, and ability to rapidly separate compounds with a wide range of mass and charge while consuming only nanoliters of samples, has become a valuable analytical technique for the analysis of complex biological mixtures. These advances have allowed a single capillary to analyze a range of compounds including amino acids, their D/L enantiomers, protein digests, intact proteins, and protein complexes. With these capabilities, CE-MS is poised to become the multipurpose tool of separation scientists. More recently, an eight-capillary CE in conjunction with an 8-inlet mass spectrometry has allowed 8 CE-MS analyses to be performed concurrently, significantly increasing throughput.
Collapse
MESH Headings
- Amino Acids/chemistry
- Amino Acids/isolation & purification
- Animals
- Coordination Complexes/chemistry
- Coordination Complexes/isolation & purification
- Crown Ethers
- Electrolytes/chemistry
- Electrophoresis, Capillary/instrumentation
- Electrophoresis, Capillary/methods
- Electrophoresis, Capillary/standards
- Erythrocytes/chemistry
- Humans
- Limit of Detection
- Metalloproteins/chemistry
- Metalloproteins/isolation & purification
- Multiprotein Complexes/isolation & purification
- Porosity
- Reference Standards
- Sequence Analysis, Protein
- Spectrometry, Mass, Electrospray Ionization/instrumentation
- Spectrometry, Mass, Electrospray Ionization/methods
- Spectrometry, Mass, Electrospray Ionization/standards
- Stereoisomerism
Collapse
Affiliation(s)
- Mehdi Moini
- Museum Conservation Institute, Smithsonian Institution, Suitland, MD, USA.
| |
Collapse
|
8
|
Wang Y, Fonslow BR, Wong CCL, Nakorchevsky A, Yates JR. Improving the comprehensiveness and sensitivity of sheathless capillary electrophoresis-tandem mass spectrometry for proteomic analysis. Anal Chem 2012; 84:8505-13. [PMID: 23004022 DOI: 10.1021/ac301091m] [Citation(s) in RCA: 111] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/21/2023]
Abstract
We describe a solid phase microextraction (SPME), multistep elution, transient isotachophoresis (tITP) capillary electrophoresis-tandem mass spectrometry (CE-MS/MS) procedure which employs a high sensitivity porous electrospray ionization (ESI) sprayer for the proteomic analysis of a moderately complex protein mixture. In order to improve comprehensiveness and sensitivity over a previously reported proteomic application of the ESI sprayer, we evaluated preconcentration with SPME and multistep elution prior to tITP stacking and CE separation. To maximize separation efficiency, we primarily employed electrokinetic methods for elution and separation after loading the sample by application of pressure. Conditions were developed for optimum simultaneous electrokinetic elution and sample stacking using a tryptic digest of 16 proteins to maximize peptide identifications and minimize band broadening. We performed comparative proteomic analysis of a dilution series using CE and nanoflow liquid chromatography (nLC). We found complementary peptide and protein identifications with larger quantities (100 ng) of a Pyrococcus furiosus tryptic digest, but with mass-limited amounts (5 ng) CE was 3 times more effective at identifying proteins. We attribute these gains in sensitivity to lower noise levels with the porous CE sprayer, illustrated by better signal-to-noise ratios of peptide precursor ions and associated higher XCorr values of identified peptides when compared directly to nLC. From comparative analysis of SPME-tITP-CE with direct injection CE, the SPME-tITP process improved comprehensiveness and sensitivity.
Collapse
Affiliation(s)
- Yueju Wang
- Department of Chemical Physiology, The Scripps Research Institute, 10550 North Torrey Pines Road, La Jolla, California 92037, United States
| | | | | | | | | |
Collapse
|
9
|
Goyder MS, Willison KR, Klug DR, Demello AJ, Ces O. Affinity chromatography and capillary electrophoresis for analysis of the yeast ribosomal proteins. BMB Rep 2012; 45:233-8. [PMID: 22531133 DOI: 10.5483/bmbrep.2012.45.4.233] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
We present a top down separation platform for yeast ribosomal proteins using affinity chromatography and capillary electrophoresis which is designed to allow deposition of proteins onto a substrate. FLAG tagged ribosomes were affinity purified, and rRNA acid precipitation was performed on the ribosomes followed by capillary electrophoresis to separate the ribosomal proteins. Over 26 peaks were detected with excellent reproducibility (<0.5% RSD migration time). This is the first reported separation of eukaryotic ribosomal proteins using capillary electrophoresis. The two stages in this workflow, affinity chromatography and capillary electrophoresis, share the advantages that they are fast, flexible and have small sample requirements in comparison to more commonly used techniques. This method is a remarkably quick route from cell to separation that has the potential to be coupled to high throughput readout platforms for studies of the ribosomal proteome.
Collapse
Affiliation(s)
- Miriam S Goyder
- The Single Cell Proteomics Group, Institute of Chemical Biology, Department of Chemistry, Imperial College London, South Kensington, London, UK
| | | | | | | | | |
Collapse
|
10
|
Moini M, Jiang L, Bootwala S. High-throughput analysis using gated multi-inlet mass spectrometry. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2011; 25:789-794. [PMID: 21337641 DOI: 10.1002/rcm.4924] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
Gated multi-inlet mass spectrometry is introduced for high-throughput chemical analysis. In this design, multiple high-pressure liquid chromatography (HPLC) columns or capillary electrophoresis (CE) capillaries are attached to multiple electrosprayers (one for each column or capillary) that spray toward a gated multi-inlet time-of-flight mass spectrometer (TOF-MS). Although all of the sprayers are spraying continuously, only one inlet is exposed at any given time for a specific duration set by the MS data system. The gated multi-sprayer, multi-inlet design significantly enhances the performance of the multi-ESI, multi-inlet TOF-MS with minimal cost and reduces analysis time. The gated multi-sprayer, multi-inlet design was applied to the investigation of column-to-column reproducibility of multiple HPLCs using a peptide mixture and to the simultaneous analysis of four protein digests. In addition, it was applied to the analysis of peptide mixtures using eight CE capillaries. The gated multi-inlet MS has several advantages compared to our previous non-gated multi-inlet MS. For example, because only one inlet is open at one time, the original manufacturer's inlet inner diameter and pumping system can be used, which enhances the sensitivity of detection for each inlet and minimizes the manufacturing cost. In addition, the number of inlets can be increased as desired. The maximum number of liquid streams that can be concurrently analyzed is limited by: (1) the number of inlets, (2) the chromatographic (electrophoretic) peak width, and (3) how fast the gate can move from one position to the next.
Collapse
Affiliation(s)
- Mehdi Moini
- Museum Conservation Institute, Smithsonian Institution, Suitland, MD 20746-2863, USA.
| | | | | |
Collapse
|
11
|
Reschke BR, Schiffbauer J, Edwards BF, Timperman AT. Simultaneous separation and detection of cations and anions on a microfluidic device with suppressed electroosmotic flow and a single injection point. Analyst 2010; 135:1351-9. [DOI: 10.1039/b921914e] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
12
|
Shi LH, Jin YX, Moon DC, Kim SK, Park SR. A sheathless CE/ESI-MS interface with an ionophore membrane-packed electro-conduction channel. Electrophoresis 2009; 30:1661-9. [DOI: 10.1002/elps.200800664] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
13
|
Abstract
In the postgenomic era, proteomics has become a dominant field for identifying and quantifying the complex protein machinery of the cell. The expression levels, posttranslational modifications, and specific interactions of proteins control the biology of such processes as development, differentiation, and signal transduction. Studies of the proteins involved in these processes often lead to a better understanding of biology and of human disease. Powerful separation techniques and sensitive detection methods enable researchers to untangle these complicated networks of processes. CE coupled with either MS or LIF are two of the techniques that make this possible. This review will cover proven CE-based methods for proteomics on the cell and tissue level and their application in biological and clinical studies, relevant new developments in enabling technology such as microfluidic CE-MS demonstrated on model systems, and comment on the future of CE in proteomics.
Collapse
MESH Headings
- Amino Acid Sequence
- Electrophoresis, Capillary/instrumentation
- Electrophoresis, Capillary/methods
- Humans
- Molecular Sequence Data
- Proteins/analysis
- Proteins/genetics
- Proteome/analysis
- Proteomics/methods
- Sequence Alignment
- Spectrometry, Mass, Electrospray Ionization/instrumentation
- Spectrometry, Mass, Electrospray Ionization/methods
- Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization/instrumentation
- Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization/methods
Collapse
Affiliation(s)
- Bryan R Fonslow
- Department of Chemical Physiology, The Scripps Research Institute, La Jolla, CA 92037, USA
| | | |
Collapse
|
14
|
Bunger MK, Cargile BJ, Ngunjiri A, Bundy JL, Stephenson JL. Automated Proteomics of E. coli via Top-Down Electron-Transfer Dissociation Mass Spectrometry. Anal Chem 2008; 80:1459-67. [DOI: 10.1021/ac7018409] [Citation(s) in RCA: 62] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Maureen K. Bunger
- Mass Spectrometry Research Program, Research Triangle Institute, 3040 Cornwallis Road, Research Triangle Park, North Carolina 27709
| | - Benjamin J. Cargile
- Mass Spectrometry Research Program, Research Triangle Institute, 3040 Cornwallis Road, Research Triangle Park, North Carolina 27709
| | - Anne Ngunjiri
- Mass Spectrometry Research Program, Research Triangle Institute, 3040 Cornwallis Road, Research Triangle Park, North Carolina 27709
| | - Jonathan L. Bundy
- Mass Spectrometry Research Program, Research Triangle Institute, 3040 Cornwallis Road, Research Triangle Park, North Carolina 27709
| | - James L. Stephenson
- Mass Spectrometry Research Program, Research Triangle Institute, 3040 Cornwallis Road, Research Triangle Park, North Carolina 27709
| |
Collapse
|
15
|
Haselberg R, de Jong GJ, Somsen GW. Capillary electrophoresis–mass spectrometry for the analysis of intact proteins. J Chromatogr A 2007; 1159:81-109. [PMID: 17560583 DOI: 10.1016/j.chroma.2007.05.048] [Citation(s) in RCA: 120] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2007] [Revised: 05/01/2007] [Accepted: 05/15/2007] [Indexed: 10/23/2022]
Abstract
Developments in the fields of protein chemistry, proteomics and biotechnology have increased the demand for suitable analytical techniques for the analysis of intact proteins. In 1989, capillary electrophoresis (CE) was combined with mass spectrometry (MS) for the first time and its potential usefulness for the analysis of intact (i.e. non-digested) proteins was shown. This article provides an overview of the applications of CE-MS within the field of intact protein analysis. The principles of the applied CE modes and ionization techniques used for CE-MS of intact proteins are shortly described. It is shown that separations are predominantly carried out by capillary zone electrophoresis and capillary isoelectric focusing, whereas electrospray ionization (ESI) and matrix-assisted laser desorption ionization (MALDI) are the most popular ionization techniques used for interfacing. The combination of CE with inductively coupled plasma (ICP) MS for the analysis of metalloproteins is also discussed. The various CE-MS combinations are systematically outlined and tables provide extensive overviews of the applications of each technique for intact protein analysis. Selected examples are given to illustrate the usefulness of the CE-MS techniques. Examples include protein isoform assignment, single cell analysis, metalloprotein characterization, proteomics and biomarker screening. Finally, chip-based electrophoresis combined with MS is shortly treated and some of its applications are described. It is concluded that CE-MS represents a powerful tool for the analysis of intact proteins yielding unique separations and information.
Collapse
Affiliation(s)
- Rob Haselberg
- Department of Biomedical Analysis, Utrecht University, 3508 TB Utrecht, The Netherlands.
| | | | | |
Collapse
|
16
|
Frommberger M, Zürbig P, Jantos J, Krahn T, Mischak H, Pich A, Just I, Schmitt-Kopplin P, Schiffer E. Peptidomic analysis of rat urine using capillary electrophoresis coupled to mass spectrometry. Proteomics Clin Appl 2007; 1:650-60. [PMID: 21136720 DOI: 10.1002/prca.200700195] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2007] [Indexed: 11/10/2022]
Abstract
We have established and validated a protocol for the peptidomic analysis of rat urine using CE coupled to MS (CE-MS). In the first experiments, the reproducibility of the CE-MS set-up and of the established preparation procedure were assessed. To establish a first rat urinary peptidome map, samples were also analyzed using CE-FT-ICR. The subsequent analysis of independent samples from two different strains (WISTAR and CD) indicated strain-specific differences, which were validated in a blinded assessment. MS/MS revealed the presence of specific fragments from well-known urinary rat peptides, such as collagens, alpha-1-antitrypsin, and serum albumin. The CE-MS-based peptidomics platform may provide novel insights into body fluids of animal models, such as rat or mice. Together with peptide identification, the technology appears to be an excellent, complimentary, and non-invasive tool to analyze toxicological or other (patho)physiological effects of pharmaceutical compounds in animal models.
Collapse
Affiliation(s)
- Moritz Frommberger
- Institute of Ecological Chemistry, GSF - National Research Center for Environment and Health, Neuherberg, Germany
| | | | | | | | | | | | | | | | | |
Collapse
|
17
|
Sniehotta M, Schiffer E, Zürbig P, Novak J, Mischak H. CE – a multifunctional application for clinical diagnosis. Electrophoresis 2007; 28:1407-17. [PMID: 17427258 DOI: 10.1002/elps.200600581] [Citation(s) in RCA: 38] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
CE has been used widely as an analytical tool with high separation power taking advantage of size, charge-to-size ratio, or isoelectric point of various analytes. In combination with detection methods, such as UV absorption, electrochemical detection, fluorescence, or mass spectrometry (MS), it allows the separation and detection of inorganic and organic ions, as well as complex compounds, such as polypeptides, nucleic acids, including PCR amplicons from viruses or bacteria. Recent interest in identification of biomarkers of diseases using body fluids leads to development of CE-MS techniques. These applications allowed identification of new potential biomarkers for clinical diagnosis and monitoring of therapeutic interventions. In this report, we present a technical overview of various CE techniques and discuss their applications in clinical medicine.
Collapse
Affiliation(s)
- Maike Sniehotta
- Mosaiques Diagnostics and Therapeutics AG, Hannover, Germany
| | | | | | | | | |
Collapse
|
18
|
Zamfir AD. Recent advances in sheathless interfacing of capillary electrophoresis and electrospray ionization mass spectrometry. J Chromatogr A 2007; 1159:2-13. [PMID: 17428492 DOI: 10.1016/j.chroma.2007.03.115] [Citation(s) in RCA: 58] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2006] [Revised: 03/20/2007] [Accepted: 03/29/2007] [Indexed: 01/13/2023]
Abstract
On line sheathless capillary electrophoresis (CE)-electrospray ionization (ESI) mass spectrometry is developing as a powerful method in bioanalytics as it provides high resolution, sensitivity, relatively short analysis times, and amenability to a wide class of compounds. However, unlike the popular nano liquid chromatography (nano LC) or sheath-flow CE/ESI-MS, the sheathless coupling lacks standardized designs and protocols. For this reason, sheathless CE/ESI is a subject of conceptual and technical upgrading more than any other liquid-based separation method hyphenated to MS. Here, recent innovations in sheathless CE/ESI-MS interfacing are gathered in a survey covering the 2005/2006 period. In the first part of the review, the current concepts and methods for in-laboratory production of sturdy designs based on either conductive emitters or electrodeless interfaces are described. The second part is dedicated to microchip CE platforms with externally connected emitters for sheathless coupling to ESI-MS and advanced microfluidic devices integrating CE and sheathless electrospray in a single chip substrate. The advantages, limitations and feasibility for certain applications of all these systems as well as the perspectives for their performance improvement are concurrently assessed.
Collapse
Affiliation(s)
- Alina D Zamfir
- Department of Chemistry and Biology, University of Arad, Revolutiei Blvd. 1, RO-310139 Arad, Romania.
| |
Collapse
|
19
|
Bodzon-Kulakowska A, Bierczynska-Krzysik A, Dylag T, Drabik A, Suder P, Noga M, Jarzebinska J, Silberring J. Methods for samples preparation in proteomic research. J Chromatogr B Analyt Technol Biomed Life Sci 2007; 849:1-31. [PMID: 17113834 DOI: 10.1016/j.jchromb.2006.10.040] [Citation(s) in RCA: 176] [Impact Index Per Article: 10.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2006] [Accepted: 10/23/2006] [Indexed: 01/04/2023]
Abstract
Sample preparation is one of the most crucial processes in proteomics research. The results of the experiment depend on the condition of the starting material. Therefore, the proper experimental model and careful sample preparation is vital to obtain significant and trustworthy results, particularly in comparative proteomics, where we are usually looking for minor differences between experimental-, and control samples. In this review we discuss problems associated with general strategies of samples preparation, and experimental demands for these processes.
Collapse
Affiliation(s)
- Anna Bodzon-Kulakowska
- Department of Neurobiochemistry, Faculty of Chemistry, Jagiellonian University, Ingardena St. 3, 30-060 Krakow, Poland
| | | | | | | | | | | | | | | |
Collapse
|
20
|
Kustos I, Kocsis B, Kilár F. Bacterial outer membrane protein analysis by electrophoresis and microchip technology. Expert Rev Proteomics 2007; 4:91-106. [PMID: 17288518 DOI: 10.1586/14789450.4.1.91] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Outer membrane proteins are indispensable components of bacterial cells and participate in several relevant functions of the microorganisms. Changes in the outer membrane protein composition might alter antibiotic sensitivity and pathogenicity. Furthermore, the effects of various factors on outer membrane protein expression, such as antibiotic treatment, mutation, changes in the environment, lipopolysaccharide modification and biofilm formation, have been analyzed. Traditionally, the outer membrane protein profile determination was performed by sodium dodecyl sulfate polyacrylamide gel electrophoresis. Converting this technique to capillary electrophoresis format resulted in faster separation, lower sample consumption and automation. Coupling capillary electrophoresis with mass spectrometry enabled the fast identification of bacterial proteins, while immediate quantitative analysis permitted the determination of up- and downregulation of certain outer membrane proteins. Adapting capillary electrophoresis to microchip format ensured a further ten- to 100-fold decrease in separation time. Application of different separation techniques combined with various sensitive detector systems has ensured further opportunities in the field of high-throughput bacterial protein analysis. This review provides an overview using selected examples of outer membrane proteins and the development and application of the electrophoretic and microchip technologies for the analysis of these proteins.
Collapse
Affiliation(s)
- Ildikó Kustos
- University of Pécs, Department of Medical Microbiology & Immunology, Faculty of Medicine, Pécs, Hungary.
| | | | | |
Collapse
|
21
|
Garza S, Chang S, Moini M. Simplifying capillary electrophoresis-mass spectrometry operation: eliminating capillary derivatization by using self-coating background electrolytes. J Chromatogr A 2007; 1159:14-21. [PMID: 17335833 DOI: 10.1016/j.chroma.2007.02.038] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2006] [Revised: 01/30/2007] [Accepted: 02/14/2007] [Indexed: 11/24/2022]
Abstract
To simplify capillary electrophoresis-mass spectrometry (CE-MS) operation, a background electrolyte (BGE) containing a polymer additive is introduced that allows the analysis of peptides and protein mixtures in underivatized fused-silica capillaries without any pretreatment, thereby increasing throughput. The most important characteristic of these polymer additives is that they do not significantly suppress the signals of the proteins and peptides under electrospray ionization, thereby allowing them to be used as an additive to common BGEs that are used for CE-MS analysis of peptide and protein mixtures. In addition, because the fused-silica capillary inner wall is continuously coated with the polymer additive, migration irreproducibility, due to the degradation of the capillary inner wall coating, under CE-MS is minimized. High sensitivity of detection, migration reproducibility, and ease of fabrication allow CE-MS analyses that require long analysis time, such as (CE-MS/MS)n, to be performed with ease. The utility of this background electrolyte has been demonstrated for the analysis of complex protein digests and intact proteins.
Collapse
Affiliation(s)
- Selynda Garza
- Department of Chemistry and Biochemistry, The University of Texas at Austin, Austin, TX 78712, USA
| | | | | |
Collapse
|
22
|
Ganser A, Morgan MA, Weissinger EM. Going from genes to proteins in myelodysplastic syndromes. Proc Natl Acad Sci U S A 2007; 104:1109-10. [PMID: 17237221 PMCID: PMC1783135 DOI: 10.1073/pnas.0610831104] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
Affiliation(s)
- Arnold Ganser
- Department of Hematology, Hemostasis, and Oncology, Hannover Medical School, D-30625 Hannover, Germany.
| | | | | |
Collapse
|
23
|
Chi A, Bai DL, Geer LY, Shabanowitz J, Hunt DF. Analysis of intact proteins on a chromatographic time scale by electron transfer dissociation tandem mass spectrometry. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY 2007; 259:197-203. [PMID: 17364019 PMCID: PMC1826913 DOI: 10.1016/j.ijms.2006.09.030] [Citation(s) in RCA: 55] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/14/2023]
Abstract
Direct analysis of intact proteins on a chromatographic time scale is demonstrated on a modified linear ion trap mass spectrometer using sequential ion/ion reactions, electron transfer and proton transfer, to dissociate the sample and to convert the resulting peptide fragments to a mixture of singly and doubly charged species. Proteins are converted to gas-phase, multiply-charged, positive ions by electrospray ionization and then allowed to react with fluoranthene radical anions. Electron transfer to the multiply charged protein promotes random fragmentation of amide bonds along the protein backbone. Multiply charged fragment ions are then deprotonated in a second ion/ion reaction with even-electron benzoate anions. M/z values for the resulting singly and doubly charged ions are used to read a sequence of 15-40 amino acids at both the N-terminus and the C-terminus of the protein. This information, along with the measured mass of the intact protein, are employed to identify known proteins and to detect the presence of post-translational modifications. In this study, we analyze intact proteins from the Escherchia coli 70S ribosomal protein complex and identify 46 of the 55 known unique components in a single, 90 min, on-line, chromatography experiment. Truncated versions of the above proteins along with several post-translational modifications are also detected.
Collapse
|
24
|
Schiffer E, Mischak H, Novak J. High resolution proteome/peptidome analysis of body fluids by capillary electrophoresis coupled with MS. Proteomics 2006; 6:5615-27. [PMID: 16991199 DOI: 10.1002/pmic.200600230] [Citation(s) in RCA: 80] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
Abstract
All organisms contain thousands of proteins and peptides in their body fluids. A deeper insight into the functional relevance of these polypeptides under different physiological and pathophysiological conditions and the discovery of specific peptide biomarkers would greatly enhance both diagnosis and therapy of specific diseases. Proteomic methods can provide means to accomplish this grand medical vision. In this review, we will focus on the potential use of proteome analysis for clinical applications, such as disease diagnosis and assessment of response to therapy. We focus on CE coupled with MS (CE-MS) and review in detail different aspects of CE-MS coupling and the results obtained using CE-MS analysis of clinically relevant samples. We also discuss clinical applications of the technology for the diagnosis of renal diseases, urogenital cancer, and arteriosclerosis as well as monitoring the responses to therapeutic interventions.
Collapse
Affiliation(s)
- Eric Schiffer
- Mosaiques Diagnostics & Therapeutics AG, Hanover, Germany
| | | | | |
Collapse
|
25
|
Garza S, Moini M. Analysis of Complex Protein Mixtures with Improved Sequence Coverage Using (CE−MS/MS)n. Anal Chem 2006; 78:7309-16. [PMID: 17037937 DOI: 10.1021/ac0612269] [Citation(s) in RCA: 44] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Identification of proteins, in a complex protein mixture, using one-dimensional high-performance liquid chromatography tandem mass spectrometry (HPLC-MS/MS) analysis of its digest, usually suffers from low sequence coverage. There are several reasons for the low coverage including undersampling, wide concentration dynamic range of the proteins in a complex protein mixture, and wide range of electrospray ionization efficiency of peptides under each mobile-phase composition. To address this low sequence coverage, we introduce a novel technique, (CE-MS/MS)n, which utilizes the most significant advantages of CE-MS/MS, including economy of sample size, fast analysis time, and high separation efficiency, to increase the sequence coverage of a complex protein mixture. Based on these characteristics, (CE-MS/MS)n can be performed in which multiple CE-MS/MS subanalyses (injections followed by analyses) are analyzed and experimental variables are manipulated during each CE-MS/MS subanalysis in order to maximize sequence coverage. (CE-MS/MS)n is a practical technique since each CE-MS/MS subanalysis consumes <10 nL, and each CE-MS/MS subanalysis takes approximately 10 min; therefore, several subanalyses can be performed in approximately 1 h consuming only nanoliters of the sample. Two techniques have been introduced to address the undersampling: (1) (CE-MS/MS)n using dynamic exclusion. In this technique, several CE-MS/MS analyses (injection followed by separation) were performed in one run using the dynamic exclusion capability of the mass spectrometer until all peptide peaks were analyzed by MS/MS. (2) Gas-phase fractionation. In this technique, (CE-MS/MS)n is performed by scanning a narrow mass range (every approximately 100 m/z) during each CE-MS/MS subanalysis without using dynamic exclusion. Under this condition, in each subanalysis, the number of peptides available for MS/MS analysis is significantly reduced, and peptides with the same nominal masses are analyzed, thereby increasing sequence coverage. Additionally, to address the lack of detection of low-level peptides in a mixture containing a wide concentration dynamic range, the concentration of the sample was systematically increased in each subanalysis (while utilizing dynamic exclusion) so that low-intensity peptides would rise above the mass spectrometer threshold and, consequently, undergo MS/MS analysis. Moreover, to alter the ionization efficiency of peptides with low electrospray ionization efficiency, and to change the migration behavior of comigrating peptides under a specific liquid composition, the CE background electrolyte was modified in several subanalyses to further improve sequence coverage. The combination of the above-mentioned techniques was applied to the analysis of the tryptic digests of three well-characterized protein mixtures: a six-protein mixture with average MW of approximately 26,000 (standard I), a six-protein mixture with an average MW approximately 49,000 (standard II), and a more complex protein mixture containing 55 proteins (E. coli ribosomal proteins). In approximately 1 h, when the MS/MS of the peptides were manually checked, all peptides that produced peaks under electrospray ionization in the scanned range of the analysis (500-2000 m/z) and within the practical fragmentation capability of the MS (peptides with MW <3500) were identified for standard I by consuming only 200 fmol of each protein. When searched against a Swissprot database, the average sequence coverage for the standard I, II, and E. coli's ribosomal proteins were 57, 34, and 15%, respectively.
Collapse
Affiliation(s)
- Selynda Garza
- Department of Chemistry and Biochemistry, The University of Texas at Austin, Austin, Texas 78712, USA
| | | |
Collapse
|
26
|
Huang YF, Huang CC, Hu CC, Chang HT. Capillary electrophoresis-based separation techniques for the analysis of proteins. Electrophoresis 2006; 27:3503-22. [PMID: 16927348 DOI: 10.1002/elps.200600100] [Citation(s) in RCA: 67] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
CE offers the advantages of high speed, great efficiency, as well as the requirement of minimum amounts of sample and buffer for the analysis of proteins. In this review, we summarize the CE-based techniques coupled with absorption, LIF, and MS detection systems for the analysis of proteins mostly within the past 5 years. The basic principle of each technique and its advantages and disadvantages for protein analysis are discussed in brief. Advanced CE techniques, including on-column concentration techniques and high-efficiency multidimensional separation techniques, for high-throughput protein profiling of complex biological samples and/or of single cells are emphasized. Although the developed techniques provide improved peak capacity, they have not become practical tools for proteomics, mainly because of poor reproducibility, low-sample lading capacity, and low throughput due to ineffective interfaces between two separation dimensions and that between separation and MS systems. In order to identify the complexities and dynamics of the proteomes expressed by cells, tissues, or organisms, techniques providing improved analytical sensitivity, throughput, and dynamic ranges are still demanded.
Collapse
Affiliation(s)
- Yu-Fen Huang
- Department of Chemistry, National Taiwan University, Taipei, Taiwan
| | | | | | | |
Collapse
|
27
|
Kraly J, Fazal MA, Schoenherr RM, Bonn R, Harwood MM, Turner E, Jones M, Dovichi NJ. Bioanalytical Applications of Capillary Electrophoresis. Anal Chem 2006; 78:4097-110. [PMID: 16771542 DOI: 10.1021/ac060704c] [Citation(s) in RCA: 105] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Affiliation(s)
- James Kraly
- Department of Chemistry, University of Washington, Seattle, Washington 98195-1700, USA
| | | | | | | | | | | | | | | |
Collapse
|
28
|
Abstract
This review article with 304 references describes recent developments in CE of proteins, and covers the two years since the previous review (Hutterer, K., Dolník, V., Electrophoresis 2003, 24, 3998-4012) through Spring 2005. It covers topics related to CE of proteins, including modeling of the electrophoretic migration of proteins, sample pretreatment, wall coatings, improving separation, various forms of detection, special electrophoretic techniques such as affinity CE, CIEF, and applications of CE to the analysis of proteins in real-world samples including human body fluids, food and agricultural samples, protein pharmaceuticals, and recombinant protein preparations.
Collapse
|
29
|
Suh MJ, Hamburg DM, Gregory ST, Dahlberg AE, Limbach PA. Extending ribosomal protein identifications to unsequenced bacterial strains using matrix-assisted laser desorption/ionization mass spectrometry. Proteomics 2006; 5:4818-31. [PMID: 16287167 PMCID: PMC2603143 DOI: 10.1002/pmic.200402111] [Citation(s) in RCA: 46] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
A protocol has been developed that allows protein identifications using available DNA-based or protein sequences from a reference strain of a bacterial species to be extended to bacterial strains for which no prior DNA-based or protein sequence information exists. The protocol is predicated on careful isolation of a specific sub-cellular group of proteins. In this study, ribosomal proteins were chosen due to their high relative abundance and similarity in copy number per cell. After isolation of ribosomal proteins, MALDI-MS is used to acquire accurate protein molecular weights. An iterative comparison of reference protein molecular weights and identities is made to the resulting data, allowing for the straightforward identification of ribosomal proteins from any non-reference strains. This approach can reveal differences between proteins at the amino acid or post-translational level. The protocol was developed, validated and applied to ribosomal proteins from three strains of the extreme thermophile Thermus thermophilus. This approach revealed that nearly 60% of the ribosomal proteins from all three strains are identical. The extension of protein identification to additional bacterial strains can be useful in phylogenetic studies as well as in biomarker identification.
Collapse
Affiliation(s)
- Moo-Jin Suh
- Rieveschl Laboratories for Mass Spectrometry, Department of Chemistry, University of Cincinnati, Cincinnati, OH, USA
| | - Daisy-Malloy Hamburg
- Rieveschl Laboratories for Mass Spectrometry, Department of Chemistry, University of Cincinnati, Cincinnati, OH, USA
| | - Steven T. Gregory
- Department of Molecular Biology, Cell Biology and Biochemistry, Brown University, Providence, RI, USA
| | - Albert E. Dahlberg
- Department of Molecular Biology, Cell Biology and Biochemistry, Brown University, Providence, RI, USA
| | - Patrick A. Limbach
- Rieveschl Laboratories for Mass Spectrometry, Department of Chemistry, University of Cincinnati, Cincinnati, OH, USA
| |
Collapse
|
30
|
Klampfl CW. Recent advances in the application of capillary electrophoresis with mass spectrometric detection. Electrophoresis 2006; 27:3-34. [PMID: 16315165 DOI: 10.1002/elps.200500523] [Citation(s) in RCA: 106] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
This review gives an overview of applications of CE coupled to MS detection published in the literature of the last three years. The works discussed in this paper comprise a wide range of different fields of application. These include important sections such as the analysis of biomolecules, the analysis of pharmaceuticals and their metabolites in different matrices, environmental analysis, and also investigations on the composition of technical products.
Collapse
Affiliation(s)
- Christian W Klampfl
- Institute of Analytical Chemistry, Johannes Kepler University Linz, Linz, Austria.
| |
Collapse
|
31
|
Schmitt-Kopplin P, Englmann M. Capillary electrophoresis - mass spectrometry: survey on developments and applications 2003-2004. Electrophoresis 2005; 26:1209-20. [PMID: 15776480 DOI: 10.1002/elps.200410355] [Citation(s) in RCA: 92] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
The major developments and applications related to CE-MS over the last two years (2003-2004) and most of the reviews and applications found in the ISI Web of Science and publisher data bases are presented in a tabulated way. This article complements our previous review "Capillary electrophoresis - mass spectrometry: 15 years of developments and applications", Electrophoresis, 2003, 24, 3837-3867 for the last two years 2003-2004. All cited articles were analyzed in a way to illustrate (i) in which journals CE-MS-related papers were mostly found over the last decades and (ii) which commercial CE-, MS-instrumentations or CE-MS combinations were mostly used in the European, Asian, and American continent. Additionally, like it was done in our last review, the reader will rapidly find applications classified as forensics, environment, bioanalytics, pharmaceutics, and metabolites.
Collapse
Affiliation(s)
- Philippe Schmitt-Kopplin
- GSF - National Research Center for Environment and Health, Institute of Ecological Chemistry, Neuherberg, Germany.
| | | |
Collapse
|
32
|
Stutz H. Advances in the analysis of proteins and peptides by capillary electrophoresis with matrix-assisted laser desorption/ionization and electrospray-mass spectrometry detection. Electrophoresis 2005; 26:1254-90. [PMID: 15776483 DOI: 10.1002/elps.200410130] [Citation(s) in RCA: 135] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
High throughput, outstanding certainty in peptide/protein identification, exceptional resolution, and quantitative information are essential pillars in proteome research. Capillary electrophoresis (CE) coupled to mass spectrometry (MS) has proven to meet these requirements. Soft ionization techniques, such as matrix-assisted laser desorption/ionization (MALDI) and electrospray ionization (ESI), have paved the way for the story of success of CE-MS in the analysis of biomolecules and both approaches are subject of discussion in this article. Meanwhile, CE-MS is far away from representing a homogeneous field. Therefore the review will cover a vast area including the coupling of different modes of CE (capillary zone electrophoresis, capillary isoelectric foscusing, capillary electrochromatography, micellar electrokinetic chromatography, nonaqueous capillary electrophoresis) to MS as well as on-line preconcentration techniques (transient capillary isotachophoresis, solid-phase extraction, membrane preconcentration) applied to compensate for restricted detection sensitivity. Special attention is given to improvements in interfacing, namely addressing nanospray and coaxial sheath liquid design. Peptide mapping, collision-induced dissociation with subsequent tandem MS, and amendments in mass accuracy of instruments improve information validity gained from MS data. With 2-D on-line coupling of liquid chromatography (LC) and CE a further topic will be discussed. A special section is dedicated to recent attempts in establishing CE-ESI-MS in proteomics, in the clinical and diagnostic field, and in the food sector.
Collapse
Affiliation(s)
- Hanno Stutz
- University of Salzburg, Department of Molecular Biology, Division of Chemistry, Salzburg, Austria.
| |
Collapse
|
33
|
Fliser D, Wittke S, Mischak H. Capillary electrophoresis coupled to mass spectrometry for clinical diagnostic purposes. Electrophoresis 2005; 26:2708-16. [PMID: 15966014 DOI: 10.1002/elps.200500187] [Citation(s) in RCA: 82] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
The introduction of fast, sensitive, and robust techniques for proteomic analysis into clinical practice represents a major step toward a new diagnostic approach of body fluids. In addition, proteomics emerges as a key technology for the discovery of disease biomarkers in various body fluids. However, even in relatively protein-deprived body fluids such as urine, the complexity and wide dynamic range of protein expression pose a considerable challenge to both separation and identification technologies. In the present review we discuss from a clinical point-of-view recent advances of the use of proteomics in clinical diagnosis as well as therapy evaluation. We focus on capillary electrophoresis coupled to mass spectrometry (CE-MS) and discuss CE-MS from an application point of view evaluating its merits and vices with regard to biomarker discovery. This review further presents examples of clinical applications of CE-MS for detection and identification of biomarkers in urine.
Collapse
|
34
|
Simó C, Herrero M, Neusüss C, Pelzing M, Kenndler E, Barbas C, Ibáñez E, Cifuentes A. Characterization of proteins fromSpirulina platensis microalga using capillary electrophoresis-ion trap-mass spectrometry and capillary electrophoresis-time of flight-mass spectrometry. Electrophoresis 2005; 26:2674-83. [PMID: 15929060 DOI: 10.1002/elps.200500055] [Citation(s) in RCA: 41] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
In this work, a new capillary electrophoresis-mass spectrometry (CE-MS) procedure is developed to analyze proteins in Spirulina platensis microalgae. It is demonstrated that a fine optimization of several separation parameters is essential in order to achieve suitable CE-MS analysis of these proteins in natural extracts from microalgae. Namely, optimization of the composition of the separation buffer, electrospray conditions, and washing routine between runs are required in order to obtain reliable and reproducible CE-MS analyses of the main proteins found in this microalga (namely, allophycocyanin-alpha chain, allophycocyanin-beta, c-phycocyanin-alpha, and c-phycocyanin-beta). The relative molecular mass of these biopolymers is determined using two different MS instruments coupled to CE, i.e., CE-ion trap-MS and CE-time of flight-MS (CE-TOF-MS). A comparison between the results obtained with both instruments is carried out. The high resolution of the TOF-MS enables the distinction of small modifications in proteins and, thus, a more accurate mass determination. Interestingly, molecular mass values obtained by both CE-MS procedures agree very well while these experimental values are only in partial agreement with those theoretically expected (i.e., genetically derived masses). Some protein modifications due to amino acids exchange induced by nucleotide codon mutations are proposed to explain this difference.
Collapse
Affiliation(s)
- Carolina Simó
- Department of Food Analysis, Institute of Industrial Fermentations (CSIC), Madrid, Spain
| | | | | | | | | | | | | | | |
Collapse
|
35
|
Simpson DC, Smith RD. Combining capillary electrophoresis with mass spectrometry for applications in proteomics. Electrophoresis 2005; 26:1291-305. [PMID: 15765477 DOI: 10.1002/elps.200410132] [Citation(s) in RCA: 159] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Mass spectrometry (MS)-based proteomics is currently dominated by the analysis of peptides originating either from digestion of proteins separated by two-dimensional gel electrophoresis (2-DE) or from global digestion; the simple peptide mixtures obtained from digestion of gel-separated proteins do not usually require further separation, while the complex peptide mixtures obtained by global digestion are most frequently separated by chromatographic techniques. Capillary electrophoresis (CE) provides alternatives to 2-DE for protein separation and alternatives to chromatography for peptide separation. This review attempts to elucidate how the most promising CE modes, capillary zone electrophoresis (CZE) and capillary isoelectric focusing (CIEF), might best be applied to MS-based proteomics. CE-MS interfacing, mass analyzer performance, column coating to minimize analyte adsorption, and sample stacking for CZE are considered prior to examining numerous applications. Finally, multidimensional systems that incorporate CE techniques are examined; CZE often finds use as a fast, final dimension before ionization for MS, while CIEF, being an equilibrium technique, is well-suited to being the first dimension in automated fractionation systems.
Collapse
|
36
|
Wittke S, Mischak H, Walden M, Kolch W, Rädler T, Wiedemann K. Discovery of biomarkers in human urine and cerebrospinal fluid by capillary electrophoresis coupled to mass spectrometry: Towards new diagnostic and therapeutic approaches. Electrophoresis 2005; 26:1476-87. [PMID: 15765478 DOI: 10.1002/elps.200410140] [Citation(s) in RCA: 114] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/21/2023]
Abstract
We report on our results using capillary electrophoresis coupled to mass spectrometry (CE-MS) to examine human bodyfluids. To demonstrate the versatility of this approach, data on two different bodyfluids, urine and cerebrospinal fluid, are shown. CE-MS analysis of human urine enables the identification of a series of polypeptides which serve as biomarkers for a variety of different renal diseases. The polypeptides are utilized to generate disease-specific polypeptide patterns. Diagnosis of these diseases is possible based on these polypeptide patters. Further, due to the high mass accuracy, polypeptides of interest can subsequently be identified using tandem MS (MS/MS) analysis. The patterns, which are based on distinct polypeptides, allow differentiation of even similar diseases like focal-segmental glomerulosclerosis (FSGS) and minimal change disease (MCD). We present preliminary data suggesting that the indicative polypeptides also enable to evaluate therapy success. Initial data obtained on human cerebrospinal fluid strongly suggest that CE-MS analysis of low-molecular-weight proteins and peptides reveals several potential biomarkers for schizophrenia as well as Alzheimer's disease. In conclusion, the data presented here indicate that CE-MS analysis, applied towards different human bodyfluids, holds the promise to allow diagnosis, staging, and evaluation of therapy success of a large number of diseases, due to its ability to display ca. 1000 individual native polypeptides within ca. 60 min.
Collapse
Affiliation(s)
- Stefan Wittke
- Mosaiques-diagnostics and therapeutics AG, Hannover, Germany
| | | | | | | | | | | |
Collapse
|
37
|
Current literature in mass spectrometry. JOURNAL OF MASS SPECTROMETRY : JMS 2005; 40:129-140. [PMID: 15672451 DOI: 10.1002/jms.799] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
|
38
|
Monton MRN, Terabe S. Recent Developments in Capillary Electrophoresis-Mass Spectrometry of Proteins and Peptides. ANAL SCI 2005; 21:5-13. [PMID: 15675508 DOI: 10.2116/analsci.21.5] [Citation(s) in RCA: 60] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
Many researchers have invested considerable efforts toward improving capillary electrophoresis (CE)-mass spectrometry (MS) systems so they can be applied better to standard analyses. This review highlights the developments in CE-MS of proteins and peptides over the last five years. It includes the developments in interfaces, sample-enrichment techniques, microfabricated devices, and some applications, largely in capillary zone electrophoresis (CZE), capillary isoelectric focusing (CIEF) and capillary isotachophoresis formats.
Collapse
Affiliation(s)
- Maria Rowena N Monton
- Graduate School of Material Science, University of Hyogo, Kamigori, Hyogo 678-1297, Japan.
| | | |
Collapse
|
39
|
Current Awareness on Comparative and Functional Genomics. Comp Funct Genomics 2005. [PMCID: PMC2448604 DOI: 10.1002/cfg.419] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/02/2022] Open
|