1
|
Yang X, Ren X, Li P, Guo C, Li J, Li Q. Novel succinic acid based polymeric surfactants: Synthesis and performance investigation. J Mol Liq 2017. [DOI: 10.1016/j.molliq.2017.01.105] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
2
|
He J, Shamsi SA. Application of polymeric surfactants in chiral micellar electrokinetic chromatography (CMEKC) and CMEKC coupled to mass spectrometry. Methods Mol Biol 2013; 970:319-348. [PMID: 23283788 DOI: 10.1007/978-1-62703-263-6_21] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
The use of amino acid-based polymeric surfactants (a.k.a. molecular micelles) in chiral micellar electrokinetic chromatography (CMEKC) has been shown to be a successful separation mode for capillary electrophoresis (CE). In this mode, chiral compounds can be enantioseparated with high efficiency, high chiral selectivity, and versatility. This chapter describes the state-of-the art studies published in the past 5 years in CMEKC using polymeric surfactants. Recent trends in the compatibility of chiral polymeric surfactants with mass spectrometric (MS) detection suggest that this type of chiral selector may be the most promising ones for chiral CE-MS applications. The synthesis of new anionic and cationic MS-compatible polymeric surfactants and their utility in CMEKC and CMEKC-MS are demonstrated. Examples of how to run a typical CMEKC-MS experiment using univariate and multivariate optimization of CMEKC and MS parameters are discussed.
Collapse
Affiliation(s)
- Jun He
- Department of Chemistry, Center of Biotechnology and Drug Design, Georgia State University, Atlanta, GA, USA
| | | |
Collapse
|
3
|
Chankvetadze L, Servais AC, Fillet M, Salgado A, Crommen J, Chankvetadze B. Comparative enantioseparation of talinolol in aqueous and non-aqueous capillary electrophoresis and study of related selector-selectand interactions by nuclear magnetic resonance spectroscopy. J Chromatogr A 2012; 1267:206-16. [PMID: 22964050 DOI: 10.1016/j.chroma.2012.08.063] [Citation(s) in RCA: 38] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2012] [Revised: 08/17/2012] [Accepted: 08/21/2012] [Indexed: 10/27/2022]
Abstract
The enantiomers of the chiral β-blocker drug talinolol were separated with two single component sulfated β-cyclodextrin (CD) derivatives, namely heptakis (2,3-di-O-methyl-6-sulfo)-β-CD) (HDMS-β-CD) and heptakis (2,3-di-O-acetyl-6-sulfo)-β-CD) (HDAS-β-CD), in aqueous and non-aqueous capillary electrophoresis (CE). The enantiomer affinity pattern of talinolol toward these two CDs was opposite in both aqueous and non-aqueous CE. However, the enantiomer affinity pattern for a given CD derivative did not change when aqueous buffer was replaced with non-aqueous background electrolyte. The structures of the analyte-selector complexes in both, aqueous and non-aqueous electrolytes were studied using rotating frame nuclear Overhauser effect (ROESY) NMR spectroscopy. Inclusion complex formation between the enantiomers of talinolol and HDAS-β-CD was confirmed in aqueous buffer, while the complex between the enantiomers of talinolol and HDMS-β-CD was of the external type. The complex of the talinolol enantiomers with HDAS-β-CD in non-aqueous electrolyte was also of the external type. In spite of external complex formation excellent separation of the enantiomers was observed in non-aqueous CE.
Collapse
Affiliation(s)
- Lali Chankvetadze
- Institute of Physical and Analytical Chemistry, School of Exact and Natural Sciences, Tbilisi State University, Tbilisi, Georgia
| | | | | | | | | | | |
Collapse
|
4
|
Morris KF, Billiot EJ, Billiot FH, Lipkowitz KB, Southerland WM, Fang Y. Investigation of Chiral Molecular Micelles by NMR Spectroscopy and Molecular Dynamics Simulation. ACTA ACUST UNITED AC 2012; 2:240-251. [PMID: 23991355 DOI: 10.4236/ojpc.2012.24032] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
NMR spectroscopy and molecular dynamics (MD) simulation analyses of the chiral molecular micelles poly-(sodium undecyl-(L,L)-leucine-valine) (poly-SULV) and poly-(sodium undecyl-(L,L)- valine-leucine) (poly-(SUVL)) are reported. Both molecular micelles are used as chiral selectors in electrokinetic chromatography and each consists of covalently linked surfactant chains with chiral dipeptide headgroups. To provide experimental support for the structures from MD simulations, NOESY spectra were used to identify protons in close spatial proximity. Results from the NOESY analyses were then compared to radial distribution functions from MD simulations. In addition, the hydrodynamic radii of both molecular micelles were calculated from NMR-derived diffusion coefficients. Corresponding radii from the MD simulations were found to be in agreement with these experimental results. NMR diffusion experiments were also used to measure association constants for polar and non-polar binaphthyl analytes binding to both molecular micelles. Poly(SUVL) was found to bind the non-polar analyte enantiomers more strongly, while the more polar analyte enantiomers interacted more strongly with poly(SULV). MD simulations in tum showed that poly(SUL V) had a more open structure that gave greater access for water molecules to the dipeptide headgroup region.
Collapse
Affiliation(s)
- Kevin F Morris
- Department of Chemistry, Carthage College, 2001 Alford Park Drive, Kenosha, WI 53140, USA
| | | | | | | | | | | |
Collapse
|
5
|
Recent progress in capillary electrophoretic analysis of amino acid enantiomers. J Chromatogr B Analyt Technol Biomed Life Sci 2011; 879:3078-95. [DOI: 10.1016/j.jchromb.2011.03.016] [Citation(s) in RCA: 95] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2011] [Revised: 03/02/2011] [Accepted: 03/06/2011] [Indexed: 11/20/2022]
|
6
|
Aturki Z, D'Orazio G, Rocco A, Fanali S. Advances in the enantioseparation of β-blocker drugs by capillary electromigration techniques. Electrophoresis 2011; 32:2602-28. [PMID: 21905049 DOI: 10.1002/elps.201100153] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2011] [Revised: 04/08/2011] [Accepted: 04/09/2011] [Indexed: 11/07/2022]
Abstract
β-Blocker drugs or β-adrenergic blocking agents are an important class of drugs, prescribed with great frequency. They are used for various diseases, particularly for the treatment of cardiac arrhythmias, cardioprotection after myocardial infarction (heart attack), and hypertension. Almost all β-blocker drugs possess one or more stereogenic centers; however; only some of them are administered as single enantiomers. Since both enantiomers can differ in their pharmacological and toxicological properties, enantioselective analytical methods are required not only for pharmacodynamic and pharmacokinetic studies but also for quality control of pharmaceutical preparations with the determination of enantiomeric purity. In addition to the chromatographic tools, in recent years, capillary electromigration techniques (CE, CEC, and MEKC) have been widely used for enantioselective purposes employing a variety of chiral selectors, e.g. CDs, polysaccharides, macrocyclic antibiotics, proteins, chiral ion-paring agents, etc. The high separation efficiency, rapid analysi,s and low consumption of reagents of electromigration methods make them a very attractive alternative to the conventional chromatographic methods. In this review, the development and applications of electrodriven methods for the enantioseparation of β-blocker drugs are reported. The papers concerning this topic, published from January 2000 until December 2010, are summarised here. Particular attention is given to the coupling of chiral CE and CEC methods to MS, as this detector provides high sensitivity and selectivity.
Collapse
Affiliation(s)
- Zeineb Aturki
- Istituto di Metodologie Chimiche, Consiglio Nazionale delle Ricerche, Area della Ricerca di Roma, Monterotondo Scalo, Rome, Italy
| | | | | | | |
Collapse
|
7
|
Lu H, Chen G. Recent advances of enantioseparations in capillary electrophoresis and capillary electrochromatography. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2011; 3:488-508. [PMID: 32938063 DOI: 10.1039/c0ay00489h] [Citation(s) in RCA: 45] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
A comprehensive survey of recent developments and applications of capillary electromigration techniques for enantioseparations from January 2006 to June 2010 is presented. The techniques include capillary electrophoresis, chip capillary electrophoresis and capillary electrochromatography. The separation principles and the chiral recognition mechanisms are discussed. Additionally, on-line preconcentrations in chiral capillary electrophoresis are also reviewed.
Collapse
Affiliation(s)
- Huang Lu
- Ministry of Education Key Laboratory of Analysis and Detection for Food Safety, Fujian Provincial Key Laboratory of Analysis and Detection Technology for Food Safety, Department of Chemistry, Fuzhou University, Fuzhou, Fujian 350002, China.
- Department of Chemistry and Chemical Engineering, Minjiang University, Fuzhou, Fujian 350108, China
| | - Guonan Chen
- Ministry of Education Key Laboratory of Analysis and Detection for Food Safety, Fujian Provincial Key Laboratory of Analysis and Detection Technology for Food Safety, Department of Chemistry, Fuzhou University, Fuzhou, Fujian 350002, China.
- Department of Chemistry and Chemical Engineering, Minjiang University, Fuzhou, Fujian 350108, China
| |
Collapse
|
8
|
Preparation and evaluation of a monolithic molecularly imprinted polymer for the chiral separation of neurotransmitters and their analogues by capillary electrochromatography. J Chromatogr A 2011; 1218:849-55. [DOI: 10.1016/j.chroma.2010.12.054] [Citation(s) in RCA: 111] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2010] [Revised: 12/08/2010] [Accepted: 12/10/2010] [Indexed: 11/20/2022]
|
9
|
Hu SQ, Chen YL, Zhu HD, Shi HJ, Yan N, Chen XG. Effect of molecular structure of tartrates on chiral recognition of tartrate–boric acid complex chiral selectors in chiral microemulsion electrokinetic chromatography. J Chromatogr A 2010; 1217:5529-35. [DOI: 10.1016/j.chroma.2010.06.063] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2010] [Revised: 06/18/2010] [Accepted: 06/24/2010] [Indexed: 11/26/2022]
|
10
|
Wang B, He J, Shamsi SA. A high-throughput multivariate optimization for the simultaneous enantioseparation and detection of barbiturates in micellar electrokinetic chromatography-mass spectrometry. J Chromatogr Sci 2010; 48:572-83. [PMID: 20819283 PMCID: PMC3098000 DOI: 10.1093/chromsci/48.7.572] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
The R- and S-configurations of barbiturates display differences in potency and biological activity. In this study, multivariate micellar electrokinetic chromatography-mass spectrometry (MEKC-MS) approach for the simultaneous analysis of three chiral barbiturates (mephobarbital, pentobarbital, and secobarbital) is developed using a polymeric chiral surfactant. After screening 11 amino acid polymeric surfactants, polysodium N-undecenoxycarbonyl-L-isoleucinate (poly-L-SUCIL) was found to be the best chiral selector. The multivariate central composite design (CCD) is used to optimize the chiral resolution, decrease the total analysis time, and improve the ESI-MS signal-to-noise (S/N) ratio. In the preliminary set of experiments, the ranges of the factors investigated in the multivariate approaches are determined. Next, the CCD design is conducted to determine the best overall chiral resolution with shortest possible run times. This optimization resulted in simultaneous enantioseparation in less than 32 min of all three barbiturates with 3-5 fold higher sensitivity by MS compared to UV detection. The adequacy of the multivariate model is validated by three replicate experimental runs at the predicted optimum conditions. The predicted results of MEKC-MS are found to be in good agreement with the experimental data for migration times, resolution, and S/N ratio. The optimized method provided good results in terms of linearity and recovery values of chiral barbiturates spiked in human serum after solid-phase extraction procedure.
Collapse
Affiliation(s)
- Bin Wang
- Department of Chemistry, Center of Biotechnology and Drug Design, Georgia State University, Atlanta, GA 30303, USA
| | - Jun He
- Department of Chemistry, Center of Biotechnology and Drug Design, Georgia State University, Atlanta, GA 30303, USA
| | - Shahab A. Shamsi
- Department of Chemistry, Center of Biotechnology and Drug Design, Georgia State University, Atlanta, GA 30303, USA
| |
Collapse
|
11
|
Luces CA, Warner IM. Achiral and chiral separations using MEKC, polyelectrolyte multilayer coatings, and mixed mode separation techniques with molecular micelles. Electrophoresis 2010; 31:1036-43. [PMID: 20155738 PMCID: PMC4197839 DOI: 10.1002/elps.200900508] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2023]
Abstract
Mixed mode (MM) separation using a combination of MEKC and polyelectrolyte multilayer (PEM) coatings is herein reported for the separation of achiral and chiral analytes. Many analytes are difficult to separate by MEKC and PEM coatings alone. Therefore, the implementation of a MM separation provides several advantages for overcoming the limitations of these well-established methods. In this study, it was observed that achiral separations using MEKC and PEM coatings individually resulted in partial resolution of eight very similar aryl ketones when the molecular micelle (sodium poly(N-undecanoyl-L-glycinate)) concentration was varied from 0.25 to 1.00% w/v and the bilayer number varied from 2 to 4. However, when MM separation was introduced, baseline resolution was achieved for all eight analytes. In the case of chiral separations, temazepam, aminoglutethimide, benzoin, benzoin methyl ether, and coumachlor were separated using the three separation techniques. For chiral separations, the chiral molecular micelle, sodium poly(N-undecanoyl-L-leucylvalinate), was employed at concentrations of 0.25-1.50% w/v for both MEKC and PEM coatings. Overall, the results revealed partial separation with MEKC and PEM coatings individually. However, MM separation enabled baseline separation of each chiral mixture. The separation of achiral and chiral compounds from different compound classes demonstrates the versatility of this MM approach.
Collapse
Affiliation(s)
- Candace A. Luces
- Department of Chemistry, Louisiana State University, Baton Rouge, LA 70803
| | - Isiah M. Warner
- Department of Chemistry, Louisiana State University, Baton Rouge, LA 70803
| |
Collapse
|
12
|
Viglio S, Fumagalli M, Ferrari F, Iadarola P. MEKC: A powerful tool for the determination of amino acids in a variety of biomatrices. Electrophoresis 2010; 31:93-104. [DOI: 10.1002/elps.200900366] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
|
13
|
Sánchez-Hernández L, GarcÃa-Ruiz C, Luisa Marina M, Luis Crego A. Recent approaches for enhancing sensitivity in enantioseparations by CE. Electrophoresis 2010; 31:28-43. [DOI: 10.1002/elps.200900429] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
14
|
Schröder S, Brandmüller A, Deng X, Ahmed A, Wätzig H. Improving precision in gel electrophoresis by stepwisely decreasing variance components. J Pharm Biomed Anal 2009; 50:320-7. [DOI: 10.1016/j.jpba.2009.04.034] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2009] [Revised: 04/27/2009] [Accepted: 04/29/2009] [Indexed: 11/30/2022]
|
15
|
He J, Shamsi SA. Multivariate approach for the enantioselective analysis in MEKC-MS: II. Optimization of 1,1'-binaphthyl-2,2'-diamine in positive ion mode. J Sep Sci 2009; 32:1916-26. [PMID: 19479771 DOI: 10.1002/jssc.200800711] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Enantiomeric separation and detection of 1,1'-binaphthyl-2,2'-diamine (BNA) has been successfully optimized by MEKC-ESI-MS using a polymeric surfactant polysodium N-undecenoxycarbonyl-L-leucinate (poly-L-SUCL) as a pseudostationary phase. In the first step, MEKC conditions were optimized by a five-factor three-level central composite design (CCD) of experiment. All five MEKC factors (buffer pH, percentage of ACN in the running buffer, concentration of surfactant, concentration of ammonium acetate (NH4OAc), and voltage) were found significant to the responses (measured as the chiral resolution and analysis time). The interactions between MEKC factors were further evaluated using a quadratic model equation which allowed the generation of 3-D response surface image to reach the optimum conditions. To obtain the best S/N, sheath liquid composition and spray chamber parameters were successfully optimized using the same strategy. Baseline enantiomeric resolution in less than 20 min and optimum MS signal of BNA enantiomers (S/N = 45 at 0.4 mg/mL) were ultimately achieved at the optimized conditions. The adequacy of the model was validated by experimental runs at the optimal predicted conditions. The predicted results were found to be in good agreement with the experimental data.
Collapse
Affiliation(s)
- Jun He
- Department of Chemistry, Center of Biotechnology and Drug Design, Georgia State University, Atlanta, GA 30303, USA
| | | |
Collapse
|
16
|
Castro-Puyana M, Drewnowska R, Pérez-Fernández V, Ángeles García M, Crego AL, Marina ML. Simultaneous separation of epinephrine and norepinephrine enantiomers by EKC: Application to the analysis of pharmaceutical formulations. Electrophoresis 2009; 30:2947-54. [DOI: 10.1002/elps.200900250] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
17
|
Palmer CP. Recent progress in the use of ionic polymers as pseudostationary phases for electrokinetic chromatography. Electrophoresis 2009; 30:163-8. [DOI: 10.1002/elps.200800420] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
18
|
Preinerstorfer B, Lämmerhofer M, Lindner W. Advances in enantioselective separations using electromigration capillary techniques. Electrophoresis 2009; 30:100-32. [DOI: 10.1002/elps.200800607] [Citation(s) in RCA: 140] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
19
|
Chiral separation by capillary electromigration techniques. J Chromatogr A 2008; 1204:140-56. [DOI: 10.1016/j.chroma.2008.07.071] [Citation(s) in RCA: 208] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2008] [Revised: 06/27/2008] [Accepted: 07/08/2008] [Indexed: 11/19/2022]
|
20
|
Abstract
Recent research and development efforts concerning polymeric pseudostationary phases (PSPs) for electrokinetic chromatography are reviewed. The introduction of new materials, characterization of structural effects on performance and selectivity, applications, and the use of polymeric PSPs with mass spectrometric detection are considered. Very interesting results concerning the effects of polymer structure have been reported. Significant developments have also been reported in the development of novel applications of polymeric PSPs, particularly for sample preconcentration using micellar affinity gradient focusing. The use of mass spectrometric detection with electrokinetic chromatography has seen significant development, and recent reports indicate that this is a robust and sensitive approach.
Collapse
Affiliation(s)
- Christopher P Palmer
- Australian Centre for Research, on Separation Science (ACROSS), School of Chemistry, University of Tasmania, Hobart, Tasmania, Australia.
| |
Collapse
|