1
|
Bao P, Paterson DA, Harrison PL, Miller K, Peyman S, Jones JC, Sandoe J, Evans SD, Bushby RJ, Gleeson HF. Lipid coated liquid crystal droplets for the on-chip detection of antimicrobial peptides. LAB ON A CHIP 2019; 19:1082-1089. [PMID: 30785139 PMCID: PMC6484679 DOI: 10.1039/c8lc01291a] [Citation(s) in RCA: 45] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/27/2018] [Accepted: 01/28/2019] [Indexed: 05/22/2023]
Abstract
We describe a novel biosensor based on phospholipid-coated nematic liquid crystal (LC) droplets and demonstrate the detection of Smp43, a model antimicrobial peptide (AMP) from the venom of North African scorpion Scorpio maurus palmatus. Mono-disperse lipid-coated LC droplets of diameter 16.7 ± 0.2 μm were generated using PDMS microfluidic devices with a flow-focusing configuration and were the target for AMPs. The droplets were trapped in a bespoke microfluidic trap structure and were simultaneously treated with Smp43 at gradient concentrations in six different chambers. The disruption of the lipid monolayer by the Smp43 was detected (<6 μM) at concentrations well within its biologically active range, indicated by a dramatic change in the appearance of the droplets associated with the transition from a typical radial configuration to a bipolar configuration, which is readily observed by polarizing microscopy. This suggests the system has feasibility as a drug-discovery screening tool. Further, compared to previously reported LC droplet biosensors, this LC droplet biosensor with a lipid coating is more biologically relevant and its ease of use in detecting membrane-related biological processes and interactions has the potential for development as a reliable, low-cost and disposable point of care diagnostic tool.
Collapse
Affiliation(s)
- Peng Bao
- School of Physics and Astronomy
, University of Leeds
,
Leeds
, UK
.
;
;
| | - Daniel A. Paterson
- School of Physics and Astronomy
, University of Leeds
,
Leeds
, UK
.
;
;
| | | | - Keith Miller
- Biomolecular Research Centre
, Sheffield Hallam University
,
Sheffield
, UK
| | - Sally Peyman
- School of Physics and Astronomy
, University of Leeds
,
Leeds
, UK
.
;
;
| | - J. Cliff Jones
- School of Physics and Astronomy
, University of Leeds
,
Leeds
, UK
.
;
;
| | - Jonathan Sandoe
- Leeds Institute of Biomedical & Clinical Science
, University of Leeds
,
Leeds
, UK
| | - Stephen D. Evans
- School of Physics and Astronomy
, University of Leeds
,
Leeds
, UK
.
;
;
| | - Richard J. Bushby
- School of Physics and Astronomy
, University of Leeds
,
Leeds
, UK
.
;
;
| | - Helen F. Gleeson
- School of Physics and Astronomy
, University of Leeds
,
Leeds
, UK
.
;
;
| |
Collapse
|
2
|
A Diffusion-Based pH Regulator in Laminar Flows with Smartphone-Based Colorimetric Analysis. MICROMACHINES 2018; 9:mi9120616. [PMID: 30477093 PMCID: PMC6315573 DOI: 10.3390/mi9120616] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/20/2018] [Revised: 11/07/2018] [Accepted: 11/19/2018] [Indexed: 01/10/2023]
Abstract
A strategy for an on-chip pH regulator is demonstrated computationally and experimentally, based on the diffusion characteristics of aqueous ionic solutions. Micro-flows with specific pH values are formed based on the diffusion behaviors of hydrogen and hydroxide ions in laminar flows. The final achieved pH value and its gradient in the channel can be regulated by the amount of ions transported between laminar flows, and the experimental results can be further generalized based on the normalized Nernst-Planck equation. A smartphone was applied as an image capture and analysis instrument to quantify pH values of liquids in a colorimetric detection process, with monotonic response range of ~1⁻13.
Collapse
|
3
|
Rambach RW, Biswas P, Yadav A, Garstecki P, Franke T. Fast selective trapping and release of picoliter droplets in a 3D microfluidic PDMS multi-trap system with bubbles. Analyst 2018; 143:843-849. [PMID: 29234760 DOI: 10.1039/c7an01100h] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Abstract
The selective manipulation and incubation of individual picoliter drops in high-throughput droplet based microfluidic devices still remains challenging. We used a surface acoustic wave (SAW) to induce a bubble in a 3D designed multi-trap polydimethylsiloxane (PDMS) device to manipulate multiple droplets and demonstrate the selection, incubation and on-demand release of aqueous droplets from a continuous oil flow. By controlling the position of the acoustic actuation, individual droplets are addressed and selectively released from a droplet stream of 460 drops per s. A complete trapping and releasing cycle can be as short as 70 ms and has no upper limit for incubation time. We characterize the fluidic function of the hybrid device in terms of electric power, pulse duration and acoustic path.
Collapse
Affiliation(s)
- Richard W Rambach
- Soft Matter and Biological Physics Group, Universität Augsburg, Universitätsstr. 1, D-86159 Augsburg, Germany
| | | | | | | | | |
Collapse
|
4
|
High-throughput screening approaches and combinatorial development of biomaterials using microfluidics. Acta Biomater 2016; 34:1-20. [PMID: 26361719 DOI: 10.1016/j.actbio.2015.09.009] [Citation(s) in RCA: 65] [Impact Index Per Article: 8.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2015] [Revised: 09/07/2015] [Accepted: 09/08/2015] [Indexed: 12/11/2022]
Abstract
From the first microfluidic devices used for analysis of single metabolic by-products to highly complex multicompartmental co-culture organ-on-chip platforms, efforts of many multidisciplinary teams around the world have been invested in overcoming the limitations of conventional research methods in the biomedical field. Close spatial and temporal control over fluids and physical parameters, integration of sensors for direct read-out as well as the possibility to increase throughput of screening through parallelization, multiplexing and automation are some of the advantages of microfluidic over conventional, 2D tissue culture in vitro systems. Moreover, small volumes and relatively small cell numbers used in experimental set-ups involving microfluidics, can potentially decrease research cost. On the other hand, these small volumes and numbers of cells also mean that many of the conventional molecular biology or biochemistry assays cannot be directly applied to experiments that are performed in microfluidic platforms. Development of different types of assays and evidence that such assays are indeed a suitable alternative to conventional ones is a step that needs to be taken in order to have microfluidics-based platforms fully adopted in biomedical research. In this review, rather than providing a comprehensive overview of the literature on microfluidics, we aim to discuss developments in the field of microfluidics that can aid advancement of biomedical research, with emphasis on the field of biomaterials. Three important topics will be discussed, being: screening, in particular high-throughput and combinatorial screening; mimicking of natural microenvironment ranging from 3D hydrogel-based cellular niches to organ-on-chip devices; and production of biomaterials with closely controlled properties. While important technical aspects of various platforms will be discussed, the focus is mainly on their applications, including the state-of-the-art, future perspectives and challenges. STATEMENT OF SIGNIFICANCE Microfluidics, being a technology characterized by the engineered manipulation of fluids at the submillimeter scale, offers some interesting tools that can advance biomedical research and development. Screening platforms based on microfluidic technologies that allow high-throughput and combinatorial screening may lead to breakthrough discoveries not only in basic research but also relevant to clinical application. This is further strengthened by the fact that reliability of such screens may improve, since microfluidic systems allow close mimicking of physiological conditions. Finally, microfluidic systems are also very promising as micro factories of a new generation of natural or synthetic biomaterials and constructs, with finely controlled properties.
Collapse
|
5
|
Bithi SS, Vanapalli SA. Collective dynamics of non-coalescing and coalescing droplets in microfluidic parking networks. SOFT MATTER 2015; 11:5122-5132. [PMID: 26036726 DOI: 10.1039/c5sm01077b] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
We study the complex collective dynamics mediated by flow resistance interactions when trains of non-coalescing and coalescing confined drops are introduced into a microfluidic parking network (MPN). The MPN consists of serially connected loops capable of parking arrays of drops. We define parking modes based on whether drops park without breakage or drop fragments are parked subsequent to breakage or drops park after coalescence. With both non-coalescing and coalescing drops, we map the occurrence of these parking modes in MPNs as a function of system parameters including drop volume, drop spacing and capillary number. We find that the non-coalescing drops can either park or break in the network, producing highly polydisperse arrays. We further show that parking due to collision induced droplet break-up is the main cause of polydispersity. We discover that collisions occur due to a crowding instability, which is a natural outcome of the network topology. In striking contrast, with coalescing drops we show that the ability of drops to coalesce rectifies the volume of parked polydisperse drops, despite drops breaking in the network. We find that several parking modes act in concert during this hydrodynamic self-rectification mechanism, producing highly monodisperse drop arrays over a wide operating parameter space. We demonstrate that the rectification mechanism can be harnessed to produce two-dimensional arrays of microfluidic drops with highly tunable surface-to-volume ratios, paving the way for fundamental investigations of interfacial phenomena in emulsions.
Collapse
Affiliation(s)
- Swastika S Bithi
- Department of Chemical Engineering, Texas Tech University, Lubbock, TX 79409, USA.
| | | |
Collapse
|
6
|
Wang K, Qin K, Wang T, Luo G. Ultra-thin liquid film extraction based on a gas–liquid–liquid double emulsion in a microchannel device. RSC Adv 2015. [DOI: 10.1039/c4ra14489a] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
A gas–liquid–liquid double emulsion with ultra-thin liquid film is proposed for the mass transfer enhancement of an extreme phase ratio system.
Collapse
Affiliation(s)
- Kai Wang
- The State Key Lab of Chemical Engineering
- Department of Chemical Engineering
- Tsinghua University
- Beijing 100084
- China
| | - Kang Qin
- The State Key Lab of Chemical Engineering
- Department of Chemical Engineering
- Tsinghua University
- Beijing 100084
- China
| | - Tao Wang
- The State Key Lab of Chemical Engineering
- Department of Chemical Engineering
- Tsinghua University
- Beijing 100084
- China
| | - Guangsheng Luo
- The State Key Lab of Chemical Engineering
- Department of Chemical Engineering
- Tsinghua University
- Beijing 100084
- China
| |
Collapse
|
7
|
Zhou H, Li G, Yao S. A droplet-based pH regulator in microfluidics. LAB ON A CHIP 2014; 14:1917-1922. [PMID: 24745036 DOI: 10.1039/c3lc51442k] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
In this paper, we develop a strategy to form on-demand droplets with specific pH values. The pH control is based on electrolysis of water in microfluidics, and the produced hydrogen and hydroxyl ions are separated and confined in individual containers during the droplet generation, triggered by a pressure pulse. By tuning the applied voltages and pressure pulses, we can control on demand the pH value in a droplet.
Collapse
Affiliation(s)
- Hongbo Zhou
- Department of Mechanical and Aerospace Engineering, Hong Kong University of Science and Technology, Hong Kong, China.
| | | | | |
Collapse
|
8
|
Zhang Q, Liu X, Liu D, Gai H. Ultra-small droplet generation via volatile component evaporation. LAB ON A CHIP 2014; 14:1395-1400. [PMID: 24584363 DOI: 10.1039/c3lc51183a] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
In this paper, we present a novel method to generate ultra-small droplets via volatile component evaporation. By regulating the composition of the binary solvent, the volume ratio of the high saturated vapor pressure component, and the flow rate ratio of the two phases, monodisperse ultra-small water or nonvolatile organic droplets can be formed. This method is flexible, versatile, and compatible with tip-streaming or nanofluidics, and may have potential applications in single molecule assay, colloid synthesis, and block copolymer assembly.
Collapse
Affiliation(s)
- Qingquan Zhang
- School of Chemistry and Chemical Engineering, Jiangsu Key Laboratory of Green Synthesis for Functional Materials, Jiangsu Normal University, Jiangsu, Xuzhou, 221116, China.
| | | | | | | |
Collapse
|
9
|
Huang X, Hui W, Hao C, Yue W, Yang M, Cui Y, Wang Z. On-site formation of emulsions by controlled air plugs. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2014; 10:758-765. [PMID: 24030982 DOI: 10.1002/smll.201202659] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/26/2012] [Revised: 07/12/2013] [Indexed: 06/02/2023]
Abstract
Air plugs are usually undesirable in microfluidic systems because of their detrimental effect on the system's stability and integrity. By controlling the wetting properties as well as the topographical geometry of the microchannel, it is reported herein that air plugs can be generated in pre-defined locations to function as a unique valve, allowing for the on-site formation of various emulsions including single-component droplets, composite droplets with droplet-to-droplet concentration gradient, blood droplets, paired droplets, as well as bubble arrays without the need for precious flow control, a difficult task with conventional droplet microfluidics. Moreover, the self-generated air valve can be readily deactivated (turned off) by the introduction of an oil phase, allowing for the on-demand release of as-formed droplets for downstream applications. It is proposed that the simple, yet versatile nature of this technique can act as an important method for droplet microfluidics and, in particular, is ideal for the development of affordable lab-on-a-chip systems without suffering from scalability and manufacturing challenges that typically confound the conventional droplet microfluidics.
Collapse
Affiliation(s)
- Xiaowen Huang
- Department of Mechanical and Biomedical Engineering, City University of Hong Kong, Hong Kong, China
| | | | | | | | | | | | | |
Collapse
|
10
|
Rodríguez-Ruiz I, Llobera A, Vila-Planas J, Johnson DW, Gómez-Morales J, García-Ruiz JM. Analysis of the Structural Integrity of SU-8-Based Optofluidic Systems for Small-Molecule Crystallization Studies. Anal Chem 2013; 85:9678-85. [DOI: 10.1021/ac402019x] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/24/2023]
Affiliation(s)
- Isaac Rodríguez-Ruiz
- Laboratorio de
Estudios Cristalográficos, IACT (CSIC-UGR), Avenida de las Palmeras, 4, 18100 Armilla, Granada, Spain
| | - Andreu Llobera
- Institut
de Microelectrónica
de Barcelona (IMB-CNM, CSIC), Campus UAB, 08193 Bellaterra, Barcelona, Catalonia, Spain
| | - Jordi Vila-Planas
- Institut
de Microelectrónica
de Barcelona (IMB-CNM, CSIC), Campus UAB, 08193 Bellaterra, Barcelona, Catalonia, Spain
| | - Donald W. Johnson
- DJ DevCorp, 490 Boston Post Road, Sudbury, Massachusetts 01776, United States
| | - Jaime Gómez-Morales
- Laboratorio de
Estudios Cristalográficos, IACT (CSIC-UGR), Avenida de las Palmeras, 4, 18100 Armilla, Granada, Spain
| | - Juan Manuel García-Ruiz
- Laboratorio de
Estudios Cristalográficos, IACT (CSIC-UGR), Avenida de las Palmeras, 4, 18100 Armilla, Granada, Spain
| |
Collapse
|
11
|
Wang Z, Chang CC, Hong SJ, Sheng YJ, Tsao HK. Trapped liquid drop in a microchannel: multiple stable states. PHYSICAL REVIEW. E, STATISTICAL, NONLINEAR, AND SOFT MATTER PHYSICS 2013; 87:062401. [PMID: 23848691 DOI: 10.1103/physreve.87.062401] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/14/2013] [Indexed: 06/02/2023]
Abstract
A liquid drop trapped in a microchannel, in which both contact angle (wettability) and opening angle (geometry) can vary with position, is investigated based on the minimization of free energy. The calculus of variation yields the Young-Laplace equation and its further integration leads to the general force balance. The equilibrium position of the trapped drop is determined by the balance between the area-mean capillary force and the area-mean hydrostatic pressure difference. Trapped liquid drops in truncated cones and hyperboloids are studied to elucidate our theory. As the volume of the drop trapped in the hydrophilic cones is increased, four regimes separated by three critical volumes are identified. The drop is either trapped at the narrow end or away from the cone top. The solution at the cone top satisfies the force balance by adjusting the upper contact angle, which is experimentally observed and verified by Surface Evolver (SE) simulations. Multiple stable states can exist in a particular regime. The hyperboloid tube in which the opening angle varies with position is also considered. As the gravitational strength is increased in hydrophilic hyperboloid, four regimes separated by three critical gravitational strengths are identified. The drop is either trapped near the neck or below the neck. Unlike hydrophilic cones, the drop stays near the neck of the hyperboloid due to varying opening angles. Multiple stable states are also observed. For both cone and hyperboloid, hydrophobic cases are studied as well and all theoretical solutions of the force balance agree well with SE simulation outcomes.
Collapse
Affiliation(s)
- Zhengjia Wang
- Department of Chemical and Materials Engineering, National Central University, Jhongli, Taiwan 320, Republic of China
| | | | | | | | | |
Collapse
|
12
|
Song K, Zhang L, Hu G. Modeling of droplet traffic in interconnected microfluidic ladder devices. Electrophoresis 2012; 33:411-8. [DOI: 10.1002/elps.201100320] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2011] [Revised: 09/08/2011] [Accepted: 10/08/2011] [Indexed: 11/09/2022]
|
13
|
Yang H, Qiao X, Bhattacharyya MK, Dong L. Microfluidic droplet encapsulation of highly motile single zoospores for phenotypic screening of an antioomycete chemical. BIOMICROFLUIDICS 2011; 5:44103-4410311. [PMID: 22662055 PMCID: PMC3364802 DOI: 10.1063/1.3651620] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/16/2011] [Accepted: 09/22/2011] [Indexed: 06/01/2023]
Abstract
Highly motile Phytophthora sojae (P. sojae) zoospores of an oomycete plant pathogen and antioomycete candidate chemicals were encapsulated into microdroplets. Random fast self-motion of P. sojae zoospores was overcome by choosing an appropriate flow rate for a zoospore suspension. To influence stochastic loading of zoospores into a microfluidic channel, a zoospore suspension was directly preloaded into a microtubing with a largely reduced inner diameter. A relatively high single zoospore encapsulation rate of 60.5% was achieved on a most trivial T-junction droplet generator platform, without involving any specially designed channel geometry. We speculated that spatial reduction in the diameter direction of microtubing added a degree of zoospore ordering in the longitudinal direction of microtubing and thus influenced positively to change the inherent limitation of stochastic encapsulation of zoospores. Comparative phenotypic study of a plant oomycete pathogen at a single zoospore level had not been achieved earlier. Phenotypic changes of zoospores responding to various chemical concentration conditions were measured in multiple droplets in parallel, providing a reliable data set and thus an improved statistic at a low chemical consumption. Since each droplet compartment contained a single zoospore, we were able to track the germinating history of individual zoospores without being interfered by other germinating zoospores, achieving a high spatial resolution. By adapting some existing droplet immobilization and concentration gradient generation techniques, the droplet approach could potentially lead to a medium-to-high throughput, reliable screening assay for chemicals against many other highly motile zoospores of pathogens.
Collapse
|
14
|
März A, Henkel T, Cialla D, Schmitt M, Popp J. Droplet formation via flow-through microdevices in Raman and surface enhanced Raman spectroscopy--concepts and applications. LAB ON A CHIP 2011; 11:3584-3592. [PMID: 21964776 DOI: 10.1039/c1lc20638a] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
This review outlines concepts and applications of droplet formation via flow-through microdevices in Raman and surface enhanced Raman spectroscopy (SERS) as well as the advantages of the approach. Even though the droplet-based flow-through technique is utilized in various fields, the review focuses on implementing droplet-based fluidic systems in Raman and SERS as these highly specific detection methods are of major interest in the field of analytics. With the combination of Raman or SERS with droplet-based fluidics, it is expected to achieve novel opportunities for analytics. Besides the approach of using droplet-based microfluidic devices as a detection platform, the unique properties of flow-through systems for the formation of droplets are capitalized to produce SERS active substrates and to accomplish uniform sample preparation. Within this contribution, previous reported applications on droplet-based flow-through Raman and SERS approaches and the additional benefit with regard to the importance in the field of analytics are considered.
Collapse
Affiliation(s)
- Anne März
- Institute of Physical Chemistry and Abbe Center of Photonics, Friedrich-Schiller University Jena, Helmholtzweg 4, 07743 Jena, Germany
| | | | | | | | | |
Collapse
|
15
|
Pompano RR, Liu W, Du W, Ismagilov RF. Microfluidics using spatially defined arrays of droplets in one, two, and three dimensions. ANNUAL REVIEW OF ANALYTICAL CHEMISTRY (PALO ALTO, CALIF.) 2011; 4:59-81. [PMID: 21370983 DOI: 10.1146/annurev.anchem.012809.102303] [Citation(s) in RCA: 70] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
Spatially defined arrays of droplets differ from bulk emulsions in that droplets in arrays can be indexed on the basis of one or more spatial variables to enable identification, monitoring, and addressability of individual droplets. Spatial indexing is critical in experiments with hundreds to millions of unique compartmentalized microscale processes--for example, in applications such as digital measurements of rare events in a large sample, high-throughput time-lapse studies of the contents of individual droplets, and controlled droplet-droplet interactions. This review describes approaches for spatially organizing and manipulating droplets in one-, two-, and three-dimensional structured arrays, including aspiration, laminar flow, droplet traps, the SlipChip, self-assembly, and optical or electrical fields. This review also presents techniques to analyze droplets in arrays and applications of spatially defined arrays, including time-lapse studies of chemical, enzymatic, and cellular processes, as well as further opportunities in chemical, biological, and engineering sciences, including perturbation/response experiments and personal and point-of-care diagnostics.
Collapse
Affiliation(s)
- Rebecca R Pompano
- Department of Chemistry and Institute for Biophysical Dynamics, The University of Chicago, Chicago, Illinois 60637, USA
| | | | | | | |
Collapse
|
16
|
Girod M, Moyano E, Campbell DI, Cooks RG. Accelerated bimolecular reactions in microdroplets studied by desorption electrospray ionization mass spectrometry. Chem Sci 2011. [DOI: 10.1039/c0sc00416b] [Citation(s) in RCA: 222] [Impact Index Per Article: 17.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
|
17
|
Bithi SS, Vanapalli SA. Behavior of a train of droplets in a fluidic network with hydrodynamic traps. BIOMICROFLUIDICS 2010; 4:44110. [PMID: 21264057 PMCID: PMC3025453 DOI: 10.1063/1.3523053] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/24/2010] [Accepted: 10/28/2010] [Indexed: 05/10/2023]
Abstract
The behavior of a droplet train in a microfluidic network with hydrodynamic traps in which the hydrodynamic resistive properties of the network are varied is investigated. The flow resistance of the network and the individual droplets guide the movement of droplets in the network. In general, the flow behavior transitions from the droplets being immobilized in the hydrodynamic traps at low flow rates to breaking up and squeezing of the droplets at higher flow rates. A state diagram characterizing these dynamics is presented. A simple hydrodynamic circuit model that treats droplets as fluidic resistors is discussed, which predicts the experimentally observed flow rates for droplet trapping in the network. This study should enable the rational design of microfuidic devices for passive storage of nanoliter-scale drops.
Collapse
Affiliation(s)
- Swastika S Bithi
- Department of Chemical Engineering, Texas Tech University, Lubbock, Texas 79409, USA
| | | |
Collapse
|
18
|
Arora A, Simone G, Salieb-Beugelaar GB, Kim JT, Manz A. Latest Developments in Micro Total Analysis Systems. Anal Chem 2010; 82:4830-47. [PMID: 20462185 DOI: 10.1021/ac100969k] [Citation(s) in RCA: 372] [Impact Index Per Article: 26.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Affiliation(s)
- Arun Arora
- KIST Europe, Korea Institute of Science and Technology, Campus E71, 66123 Saarbrücken, Germany, FRIAS, Freiburg Institute for Advanced Studies, Albert-Ludwigs-Universität Freiburg, Albertstrasse 19, 79104 Freiburg, Germany, IMTEK, Institute for Microsystem Technology, University of Freiburg, Georges-Köhler-Allee 103, 79110 Freiburg, Germany, and MESA+ Institute for Nanotechnology/Lab-on-a-Chip Group, Twente University, Building Carré, 7500 AE, Enschede, The Netherlands
| | - Giuseppina Simone
- KIST Europe, Korea Institute of Science and Technology, Campus E71, 66123 Saarbrücken, Germany, FRIAS, Freiburg Institute for Advanced Studies, Albert-Ludwigs-Universität Freiburg, Albertstrasse 19, 79104 Freiburg, Germany, IMTEK, Institute for Microsystem Technology, University of Freiburg, Georges-Köhler-Allee 103, 79110 Freiburg, Germany, and MESA+ Institute for Nanotechnology/Lab-on-a-Chip Group, Twente University, Building Carré, 7500 AE, Enschede, The Netherlands
| | - Georgette B. Salieb-Beugelaar
- KIST Europe, Korea Institute of Science and Technology, Campus E71, 66123 Saarbrücken, Germany, FRIAS, Freiburg Institute for Advanced Studies, Albert-Ludwigs-Universität Freiburg, Albertstrasse 19, 79104 Freiburg, Germany, IMTEK, Institute for Microsystem Technology, University of Freiburg, Georges-Köhler-Allee 103, 79110 Freiburg, Germany, and MESA+ Institute for Nanotechnology/Lab-on-a-Chip Group, Twente University, Building Carré, 7500 AE, Enschede, The Netherlands
| | - Jung Tae Kim
- KIST Europe, Korea Institute of Science and Technology, Campus E71, 66123 Saarbrücken, Germany, FRIAS, Freiburg Institute for Advanced Studies, Albert-Ludwigs-Universität Freiburg, Albertstrasse 19, 79104 Freiburg, Germany, IMTEK, Institute for Microsystem Technology, University of Freiburg, Georges-Köhler-Allee 103, 79110 Freiburg, Germany, and MESA+ Institute for Nanotechnology/Lab-on-a-Chip Group, Twente University, Building Carré, 7500 AE, Enschede, The Netherlands
| | - Andreas Manz
- KIST Europe, Korea Institute of Science and Technology, Campus E71, 66123 Saarbrücken, Germany, FRIAS, Freiburg Institute for Advanced Studies, Albert-Ludwigs-Universität Freiburg, Albertstrasse 19, 79104 Freiburg, Germany, IMTEK, Institute for Microsystem Technology, University of Freiburg, Georges-Köhler-Allee 103, 79110 Freiburg, Germany, and MESA+ Institute for Nanotechnology/Lab-on-a-Chip Group, Twente University, Building Carré, 7500 AE, Enschede, The Netherlands
| |
Collapse
|