1
|
Twenty years of amino acid determination using capillary electrophoresis: A review. Anal Chim Acta 2021; 1174:338233. [DOI: 10.1016/j.aca.2021.338233] [Citation(s) in RCA: 24] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2020] [Revised: 01/14/2021] [Accepted: 01/16/2021] [Indexed: 12/28/2022]
|
2
|
Huo F, Wan T, Wang Y, Liu Y, Karmaker PG, Yang X. Enhanced light-emitting diode induced fluorescence detection system with capillary electrophoresis. J Chromatogr A 2020; 1619:460935. [PMID: 32067761 DOI: 10.1016/j.chroma.2020.460935] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2019] [Revised: 12/11/2019] [Accepted: 01/29/2020] [Indexed: 11/26/2022]
Abstract
An enhanced fluorescence detection system of capillary electrophoresis (CE) was equipped with a concave silver mirror, by which the detection sensitivity of light-emitting diode induced fluorescence (LEDIF) can be increased greatly. The silver concave mirror and the cathode window in photomultiplier tube (PMT) were accurately set face to face at the same axis. When the two labeled tumor markers exactly moved to the center of detection window, the emission from analytes are excitated by LED source. Currently, the analytes may be regarded as a luminescent source point. When the source point exactly moves to the focus of the concave mirror, the emission of the labeled sample was collected effectively, enhanced by convergence and reflected by the concave mirror. Then it was sensitively detected by the PMT. The optical mechanism of enhancing detection sensitivity was explored. A simple comparative test on sensitivity was carried out, which aimed to compare sensitivity of the new detection system with concave mirror to that without concave mirror but the other conditions were kept the same. Two tumor markers labeled with FITC were selected for the test, using the simple LEDIF detect system. The results (LOD, 150 nM for L-Leu and L-Val) showed that the detection sensitivity matched with concave mirror reached more 16 times than the detection method without concave mirror.
Collapse
Affiliation(s)
- Feng Huo
- School of Chemistry and Chemical Engineering, Analytical Testing Center, Institute of Micro&Nano Intelligent Sensing, Neijiang Normal University, Neijiang, 641100, PR China; Chemical Synthesis and Pollution Control Key Laboratory of Sichuan Province, China West Normal University, Nanchong, 637000, PR China
| | - Ting Wan
- School of Chemistry and Chemical Engineering, Analytical Testing Center, Institute of Micro&Nano Intelligent Sensing, Neijiang Normal University, Neijiang, 641100, PR China; Chemical Synthesis and Pollution Control Key Laboratory of Sichuan Province, China West Normal University, Nanchong, 637000, PR China
| | - Yaohui Wang
- School of Chemistry and Chemical Engineering, Analytical Testing Center, Institute of Micro&Nano Intelligent Sensing, Neijiang Normal University, Neijiang, 641100, PR China
| | - Yuhang Liu
- School of Chemistry and Chemical Engineering, Analytical Testing Center, Institute of Micro&Nano Intelligent Sensing, Neijiang Normal University, Neijiang, 641100, PR China; Chemical Synthesis and Pollution Control Key Laboratory of Sichuan Province, China West Normal University, Nanchong, 637000, PR China
| | - Pran Gopal Karmaker
- School of Chemistry and Chemical Engineering, Analytical Testing Center, Institute of Micro&Nano Intelligent Sensing, Neijiang Normal University, Neijiang, 641100, PR China
| | - Xiupei Yang
- Chemical Synthesis and Pollution Control Key Laboratory of Sichuan Province, China West Normal University, Nanchong, 637000, PR China.
| |
Collapse
|
3
|
A facile and high sensitive micro fluorimeter based on light emitting diode and photodiode. Talanta 2017; 175:183-188. [DOI: 10.1016/j.talanta.2017.07.022] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2017] [Revised: 07/03/2017] [Accepted: 07/05/2017] [Indexed: 11/23/2022]
|
4
|
Denoroy L, Parrot S. Analysis of Amino Acids and Related Compounds by Capillary Electrophoresis. SEPARATION AND PURIFICATION REVIEWS 2016. [DOI: 10.1080/15422119.2016.1212378] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
|
5
|
Macka M, Piasecki T, Dasgupta PK. Light-emitting diodes for analytical chemistry. ANNUAL REVIEW OF ANALYTICAL CHEMISTRY (PALO ALTO, CALIF.) 2014; 7:183-207. [PMID: 24818811 DOI: 10.1146/annurev-anchem-071213-020059] [Citation(s) in RCA: 61] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
Light-emitting diodes (LEDs) are playing increasingly important roles in analytical chemistry, from the final analysis stage to photoreactors for analyte conversion to actual fabrication of and incorporation in microdevices for analytical use. The extremely fast turn-on/off rates of LEDs have made possible simple approaches to fluorescence lifetime measurement. Although they are increasingly being used as detectors, their wavelength selectivity as detectors has rarely been exploited. From their first proposed use for absorbance measurement in 1970, LEDs have been used in analytical chemistry in too many ways to make a comprehensive review possible. Hence, we critically review here the more recent literature on their use in optical detection and measurement systems. Cloudy as our crystal ball may be, we express our views on the future applications of LEDs in analytical chemistry: The horizon will certainly become wider as LEDs in the deep UV with sufficient intensity become available.
Collapse
Affiliation(s)
- Mirek Macka
- Australian Center for Research on Separation Science and School of Chemistry, University of Tasmania, Hobart, Tasmania 7001, Australia
| | | | | |
Collapse
|
6
|
Geng X, Wu D, Wu Q, Guan Y. Signal-to-noise ratio enhancement of the compact light-emitting diode-induced fluorescence detector. Talanta 2012; 100:27-31. [DOI: 10.1016/j.talanta.2012.08.043] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2012] [Revised: 08/14/2012] [Accepted: 08/27/2012] [Indexed: 10/27/2022]
|
7
|
Poinsot V, Carpéné MA, Bouajila J, Gavard P, Feurer B, Couderc F. Recent advances in amino acid analysis by capillary electrophoresis. Electrophoresis 2012; 33:14-35. [PMID: 22213525 DOI: 10.1002/elps.201100360] [Citation(s) in RCA: 57] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
This paper describes the most important articles that have been published on amino acid analysis using CE during the period from June 2009 to May 2011 and follows the format of the previous articles of Smith (Electrophoresis 1999, 20, 3078-3083), Prata et al. (Electrophoresis 2001, 22, 4129-4138) and Poinsot et al. (Electrophoresis 2003, 24, 4047-4062; Electrophoresis 2006, 27, 176-194; Electrophoresis 2008, 29, 207-223; Electrophoresis 2010, 31, 105-121). We present new developments in amino acid analysis with CE, which are reported describing the use of lasers or light emitting diodes for fluorescence detection, conductimetry electrochemiluminescence detectors, mass spectrometry applications, and lab-on-a-chip applications using CE. In addition, we describe articles concerning clinical studies and neurochemical applications of these techniques.
Collapse
Affiliation(s)
- Véréna Poinsot
- Université Paul Sabatier, IMRCP, UMR 5623, Toulouse, France
| | | | | | | | | | | |
Collapse
|
8
|
A compact and highly sensitive light-emitting diode-induced fluorescence detector for capillary flow systems. Talanta 2012; 88:463-7. [DOI: 10.1016/j.talanta.2011.11.015] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2011] [Revised: 11/02/2011] [Accepted: 11/03/2011] [Indexed: 11/19/2022]
|
9
|
Ban E, Park SH, Kang MJ, Lee HJ, Song EJ, Yoo YS. Growing trend of CE at the omics level: The frontier of systems biology - An update. Electrophoresis 2011; 33:2-13. [DOI: 10.1002/elps.201100344] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2011] [Revised: 08/16/2011] [Accepted: 08/16/2011] [Indexed: 02/03/2023]
|
10
|
He Y, Zhao L, Yuan H, Xu Z, Tang Y, Xiao D, Choi MMF. HPLC with In-Capillary Optical Fiber Laser-Induced Fluorescence Detection of Picomolar Amounts of Amino Acids by Precolumn Fluorescence Derivatization with Fluorescein Isothiocyanate. Chromatographia 2011. [DOI: 10.1007/s10337-011-2112-5] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
11
|
Kulp M, Bragina O, Kogerman P, Kaljurand M. Capillary electrophoresis with LED-induced native fluorescence detection for determination of isoquinoline alkaloids and their cytotoxicity in extracts of Chelidonium majus L. J Chromatogr A 2011; 1218:5298-304. [PMID: 21726876 DOI: 10.1016/j.chroma.2011.06.016] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2011] [Revised: 06/03/2011] [Accepted: 06/06/2011] [Indexed: 10/18/2022]
Abstract
In this study, we introduced a simple and sensitive method of capillary electrophoresis with ultraviolet light-emitting diode-induced native fluorescence (UV-LEDIF) detection for the determination of isoquinoline alkaloids in extracts of Chelidonium majus L. Samples were extracted with acidic methanol and the extracts were directly analysed by CE. Simultaneous determination of protopine, chelidonine, coptisine, sanguinarine, allocryptopine, chelerythrine and stylopine was performed in 20mM phosphate buffer (pH 3.1). The baseline separation of these alkaloids was finished within 20 min. As these alkaloids have native fluorescence, they were directly detected using the commercially available UV light emitting diode without troublesome fluorescent derivatisation. Satisfactory LOD values were obtained for the studied compounds considering their appearance in natural extracts. Lower limits of detection were 0.05 μg/mL for protopine, 0.06 μg/mL for stylopine and allocryptopine, 0.07 μg/mL for chelidonine, 0.22 μg/mL for sanguinarine, 1.7 μg/mL for chelerythrine and 5.5 μg/mL for coptisine. The developed method was successfully applied to determine the contents of seven alkaloids in the aerial parts of Chelidonium majus L, which varied from 0.025 to 0.763% (w/w). Also, to demonstrate the potential of the proposed CE method, an estimation of the cytotoxic properties of selected Celandine alkaloids in a natural extract was carried out.
Collapse
Affiliation(s)
- Maria Kulp
- Tallinn University of Technology, Department of Chemistry, Akadeemia tee 15, Tallinn, Estonia.
| | | | | | | |
Collapse
|