1
|
Fedorenko D, Bartkevics V. Recent Applications of Nano-Liquid Chromatography in Food Safety and Environmental Monitoring: A Review. Crit Rev Anal Chem 2021; 53:98-122. [PMID: 34392753 DOI: 10.1080/10408347.2021.1938968] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Abstract
In recent years, a trend toward instrument miniaturization has led to the development of new and sophisticated analytical systems, such as nano-liquid chromatography (nano-LC), which has enabled improvements of sensitivity, as well as chromatographic resolution. The growing interest in nano-LC methodology has resulted in a variety of innovative and promising applications. In this article, we review the applications of nano-LC separation methods coupled with mass spectrometry in the analysis of food and environmental samples. An assessment of sample preparation methods and analytical performance are provided, along with comparison to other, more established analytical techniques. Three main groups of compounds that are crucial for food safety assessment are considered in this review: pharmaceuticals (including antibiotics), pesticides, and mycotoxins. Recent practical applications of the nano-LC method in the determination of these compounds are discussed. Furthermore, we also focus on methods for the determination of various environmental contaminants using nano-LC methods. Future perspectives for the development of nano-LC methods are discussed.
Collapse
Affiliation(s)
- Deniss Fedorenko
- Institute of Food Safety, Animal Health and Environment "BIOR", Riga, Latvia.,University of Latvia, Faculty of Chemistry, Riga, Latvia
| | - Vadims Bartkevics
- Institute of Food Safety, Animal Health and Environment "BIOR", Riga, Latvia.,University of Latvia, Faculty of Chemistry, Riga, Latvia
| |
Collapse
|
2
|
Performance of nanoflow liquid chromatography using core-shell particles: A comparison study. J Chromatogr A 2021; 1648:462218. [PMID: 33992996 DOI: 10.1016/j.chroma.2021.462218] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2021] [Revised: 04/12/2021] [Accepted: 04/26/2021] [Indexed: 01/23/2023]
Abstract
Due to its unique structure, core-shell material has presented significantly improved chromatographic performance in comparison with conventional totally porous material. This has been well demonstrated in the analytical column format, e.g. 4.6 mm i.d. columns. In the proteomics field, there is always a demand for high resolution microseparation tools. In order to explore core-shell material's potential in proteomics-oriented microseparations, we investigated chromatographic performance of core-shell material in a nanoLC format, as well as its resolving power for protein digests. The results show core-shell nanoLC columns have similar van Deemter curves to the totally porous particle-packed nanoLC columns. For 100 µm i.d. capillary columns, the core-shell material does not have significantly better dynamics. However, both core-shell and totally porous particle-packed nanoLC columns have shown high efficiencies: plate heights of ~11 µm, equivalent to 90000 plates per meter, have been achieved with 5 µm particles. Using a 60 cm long core-shell nanoLC column, 72000 plates were realized in an isocratic separation of neutral compounds. For a 15 cm long nanoLC column, a maximum peak capacity of 220 has been achieved in a 5 hour gradient separation of protein digests, indicating the high resolving power of core-shell nanoLC columns. With a standard HeLa cell lysate as the sample, 2546 proteins were identified by using the core-shell nanoLC column, while 2916 proteins were identified by using the totally porous particle-packed nanoLC column. Comparing the two sets of proteomics data, it was found that 1830 proteins were identified by both columns, while 1086 and 716 proteins were uniquely identified by using totally porous and core-shell particle-packed nanoLC columns, respectively, suggesting their complementarity in nanoLC-MS based proteomics.
Collapse
|
3
|
Luo C, DeStefano JJ, Langlois TJ, Boyes BE, Schuster SA, Godinho JM. Fundamental to achieving fast separations with high efficiency: A review of chromatography with superficially porous particles. Biomed Chromatogr 2021; 35:e5087. [PMID: 33566360 DOI: 10.1002/bmc.5087] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2020] [Revised: 01/26/2021] [Accepted: 02/05/2021] [Indexed: 01/16/2023]
Abstract
Types of particles have been fundamental to LC separation technology for many years. Originally, LC columns were packed with large-diameter (>100 μm) calcium carbonate, silica gel, or alumina particles that prohibited fast mobile-phase speeds because of the slow diffusion of sample molecules inside deep pores. During the birth of HPLC in the 1960s, superficially porous particles (SPP, ≥30 μm) were developed as the first high-speed stationary-phase support structures commercialized, which permitted faster mobile-phase flowrates due to the fast movement of sample molecules in/out of the thin shells. These initial SPPs were displaced by smaller totally porous particles (TPP) in the mid-1970s. But SPP history repeated when UHPLC emerged in the 2000s. Stationary-phase support structures made from sub-3-μm SPPs were introduced to chromatographers in 2006. The initial purpose of this modern SPP was to enable chromatographers to achieve fast separations with high efficiency using conventional HPLCs. Later, the introduction of sub-2-μm SPPs with UHPLC instruments pushed the separation speed and efficiency to a very fast zone. This review aims at providing readers a comprehensive and up-to-date view on the advantages of SPP materials over TPPs historically and theoretically from the material science angle.
Collapse
Affiliation(s)
- Chuping Luo
- Advanced Materials Technology, Inc, Wilmington, Delaware, USA
| | | | | | - Barry E Boyes
- Advanced Materials Technology, Inc, Wilmington, Delaware, USA
| | | | | |
Collapse
|
4
|
Žuvela P, Skoczylas M, Jay Liu J, Ba Czek T, Kaliszan R, Wong MW, Buszewski B, Héberger K. Column Characterization and Selection Systems in Reversed-Phase High-Performance Liquid Chromatography. Chem Rev 2019; 119:3674-3729. [PMID: 30604951 DOI: 10.1021/acs.chemrev.8b00246] [Citation(s) in RCA: 148] [Impact Index Per Article: 29.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Abstract
Reversed-phase high-performance liquid chromatography (RP-HPLC) is the most popular chromatographic mode, accounting for more than 90% of all separations. HPLC itself owes its immense popularity to it being relatively simple and inexpensive, with the equipment being reliable and easy to operate. Due to extensive automation, it can be run virtually unattended with multiple samples at various separation conditions, even by relatively low-skilled personnel. Currently, there are >600 RP-HPLC columns available to end users for purchase, some of which exhibit very large differences in selectivity and production quality. Often, two similar RP-HPLC columns are not equally suitable for the requisite separation, and to date, there is no universal RP-HPLC column covering a variety of analytes. This forces analytical laboratories to keep a multitude of diverse columns. Therefore, column selection is a crucial segment of RP-HPLC method development, especially since sample complexity is constantly increasing. Rationally choosing an appropriate column is complicated. In addition to the differences in the primary intermolecular interactions with analytes of the dispersive (London) type, individual columns can also exhibit a unique character owing to specific polar, hydrogen bond, and electron pair donor-acceptor interactions. They can also vary depending on the type of packing, amount and type of residual silanols, "end-capping", bonding density of ligands, and pore size, among others. Consequently, the chromatographic performance of RP-HPLC systems is often considerably altered depending on the selected column. Although a wide spectrum of knowledge is available on this important subject, there is still a lack of a comprehensive review for an objective comparison and/or selection of chromatographic columns. We aim for this review to be a comprehensive, authoritative, critical, and easily readable monograph of the most relevant publications regarding column selection and characterization in RP-HPLC covering the past four decades. Future perspectives, which involve the integration of state-of-the-art molecular simulations (molecular dynamics or Monte Carlo) with minimal experiments, aimed at nearly "experiment-free" column selection methodology, are proposed.
Collapse
Affiliation(s)
- Petar Žuvela
- Department of Chemistry , National University of Singapore , Singapore 117543 , Singapore
| | - Magdalena Skoczylas
- Department of Environmental Chemistry and Bioanalytics, Center for Modern Interdisciplinary Technologies , Nicolaus Copernicus University , Wileńska 4 , 87-100 Toruń , Poland
| | - J Jay Liu
- Department of Chemical Engineering , Pukyong National University , 365 Sinseon-ro , Nam-gu, 48-513 Busan , Korea
| | | | | | - Ming Wah Wong
- Department of Chemistry , National University of Singapore , Singapore 117543 , Singapore
| | - Bogusław Buszewski
- Department of Environmental Chemistry and Bioanalytics, Center for Modern Interdisciplinary Technologies , Nicolaus Copernicus University , Wileńska 4 , 87-100 Toruń , Poland
| | | |
Collapse
|
5
|
Gumustas M, Zalewski P, Ozkan SA, Uslu B. The History of the Core–Shell Particles and Applications in Active Pharmaceutical Ingredients Via Liquid Chromatography. Chromatographia 2018. [DOI: 10.1007/s10337-018-3670-6] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
|
6
|
Electrochromatographic behavior of core-shell particles: A comparison study. Anal Chim Acta 2018; 1033:205-212. [DOI: 10.1016/j.aca.2018.06.007] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2017] [Revised: 05/09/2018] [Accepted: 06/02/2018] [Indexed: 11/22/2022]
|
7
|
Gumustas M, Caglayan MG, Onur F, Ozkan SA. Simultaneous determination and validation of emtricitabine, rilpivirine and tenofovir from biological samples using LC and CE methods. Biomed Chromatogr 2018; 32. [DOI: 10.1002/bmc.4158] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2017] [Revised: 10/25/2017] [Accepted: 11/27/2017] [Indexed: 11/05/2022]
Affiliation(s)
- Mehmet Gumustas
- Faculty of Arts & Sciences, Department of Chemistry; Hitit University; Corum Turkey
- Ankara University, Faculty of Pharmacy, Department of Analytical Chemistry; Ankara Turkey
| | - Mehmet Gokhan Caglayan
- Ankara University, Faculty of Pharmacy, Department of Analytical Chemistry; Ankara Turkey
| | - Feyyaz Onur
- Ankara University, Faculty of Pharmacy, Department of Analytical Chemistry; Ankara Turkey
| | - Sibel A. Ozkan
- Ankara University, Faculty of Pharmacy, Department of Analytical Chemistry; Ankara Turkey
| |
Collapse
|
8
|
Reising AE, Godinho JM, Jorgenson JW, Tallarek U. Bed morphological features associated with an optimal slurry concentration for reproducible preparation of efficient capillary ultrahigh pressure liquid chromatography columns. J Chromatogr A 2017; 1504:71-82. [PMID: 28511930 DOI: 10.1016/j.chroma.2017.05.007] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2017] [Revised: 04/20/2017] [Accepted: 05/04/2017] [Indexed: 11/30/2022]
Abstract
Column wall effects and the formation of larger voids in the bed during column packing are factors limiting the achievement of highly efficient columns. Systematic variation of packing conditions, combined with three-dimensional bed reconstruction and detailed morphological analysis of column beds, provide valuable insights into the packing process. Here, we study a set of sixteen 75μm i.d. fused-silica capillary columns packed with 1.9μm, C18-modified, bridged-ethyl hybrid silica particles slurried in acetone to concentrations ranging from 5 to 200mg/mL. Bed reconstructions for three of these columns (representing low, optimal, and high slurry concentrations), based on confocal laser scanning microscopy, reveal morphological features associated with the implemented slurry concentration, that lead to differences in column efficiency. At a low slurry concentration, the bed microstructure includes systematic radial heterogeneities such as particle size-segregation and local deviations from bulk packing density near the wall. These effects are suppressed (or at least reduced) with higher slurry concentrations. Concomitantly, larger voids (relative to the mean particle diameter) begin to form in the packing and increase in size and number with the slurry concentration. The most efficient columns are packed at slurry concentrations that balance these counteracting effects. Videos are taken at low and high slurry concentration to elucidate the bed formation process. At low slurry concentrations, particles arrive and settle individually, allowing for rearrangements. At high slurry concentrations, they arrive and pack as large patches (reflecting particle aggregation in the slurry). These processes are discussed with respect to column packing, chromatographic performance, and bed microstructure to help reinforce general trends previously described. Conclusions based on this comprehensive analysis guide us towards further improvement of the packing process.
Collapse
Affiliation(s)
- Arved E Reising
- Department of Chemistry, Philipps-Universität Marburg, Hans-Meerwein-Strasse 4, 35032 Marburg, Germany
| | - Justin M Godinho
- Department of Chemistry, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599-3290, United States
| | - James W Jorgenson
- Department of Chemistry, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599-3290, United States.
| | - Ulrich Tallarek
- Department of Chemistry, Philipps-Universität Marburg, Hans-Meerwein-Strasse 4, 35032 Marburg, Germany.
| |
Collapse
|
9
|
Fanali S. An overview to nano-scale analytical techniques: Nano-liquid chromatography and capillary electrochromatography. Electrophoresis 2017; 38:1822-1829. [PMID: 28256745 DOI: 10.1002/elps.201600573] [Citation(s) in RCA: 36] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2016] [Revised: 02/17/2017] [Accepted: 02/21/2017] [Indexed: 01/04/2023]
Abstract
Nano-liquid chromatography (nano-LC) and CEC are microfluidic techniques mainly used for analytical purposes. They have been applied to the separation and analysis of a large number of compounds, e.g., peptides, proteins, drugs, enantiomers, antibiotics, pesticides, nutraceutical, etc. Analytes separation is carried out into capillaries containing selected stationary phase. The mobile phase is moved either by a pump (nano-LC) or by an EOF, respectively. The two tools can offer some advantages over conventional techniques, e.g., high selectivity, separation efficiency, resolution, short analysis time and consumption of low volumes of mobile phase. Flow rates in the range 50-800 nL/min are usually applied. The low flow rate reduces the chromatographic dilution increasing the mass sensitivity. Special attention must be paid in avoiding peak dispersion selecting the appropriate detector, injector and tube connection. Finally due to the low flow rate these microfluidic techniques can be easily coupled with mass spectrometry.
Collapse
Affiliation(s)
- Salvatore Fanali
- Institute of Chemical Methodologies, Italian National Research Council, Monterotondo, Italy
| |
Collapse
|
10
|
Mateos-Vivas M, Fanali S, Rodríguez-Gonzalo E, Carabias-Martínez R, Aturki Z. Rapid determination of nucleotides in infant formula by means of nano-liquid chromatography. Electrophoresis 2016; 37:1873-80. [PMID: 26791135 DOI: 10.1002/elps.201500526] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2015] [Revised: 12/23/2015] [Accepted: 01/11/2016] [Indexed: 01/11/2023]
Abstract
A rapid method for the quantification of five ribonucleotides 5'- monophophates (adenosine, cytidine, guanosine, inosine, uridine, 5'-monophosphate), in infant formula, has been proposed using nano-LC. To separate the studied compounds, capillary columns packed with different C18-based stationary phases were investigated. All the columns tested were laboratory prepared. The experiments were performed in ion-pairing RP chromatographic mode using tetrabutylammonium hydroxide as ion-pairing reagent. The method was developed using a core-shell XB-C18 capillary column with a mobile phase consisting of 5% v/v methanol and 95% v/v 100 mM ammonium formate, pH 8, containing 20 mM tetrabutylammonium hydroxide. All compounds were baseline resolved in less than 5 min with a flow rate of 500 nL/min in isocratic elution mode. Nucleotides were detected at 260 nm. Analytical validation parameters were evaluated. The RSD values for intraday and interday repeatability for retention time and peak area were <2.4 and 4.2%, respectively. The method linearity was good (R(2) < 0.9995) for the studied compounds. LOD and limit of quantitation were 0.25 and 0.50 μg/mL, respectively. The method was applied to the determination of nucleotides in infant formula, subjected to a centrifugal ultrafiltration process, prior their analysis. The amounts found were in agreement to the labeled contents.
Collapse
Affiliation(s)
- María Mateos-Vivas
- Istituto di Metodologie Chimiche, Consiglio Nazionale delle Ricerche, Monterotondo, Italy.,Departamento de Química Analítica, Nutrición y Bromatología, Facultad de Ciencias Químicas, University of Salamanca, Salamanca, Spain
| | - Salvatore Fanali
- Istituto di Metodologie Chimiche, Consiglio Nazionale delle Ricerche, Monterotondo, Italy
| | - Encarnacíon Rodríguez-Gonzalo
- Departamento de Química Analítica, Nutrición y Bromatología, Facultad de Ciencias Químicas, University of Salamanca, Salamanca, Spain
| | - Rita Carabias-Martínez
- Departamento de Química Analítica, Nutrición y Bromatología, Facultad de Ciencias Químicas, University of Salamanca, Salamanca, Spain
| | - Zeineb Aturki
- Istituto di Metodologie Chimiche, Consiglio Nazionale delle Ricerche, Monterotondo, Italy
| |
Collapse
|
11
|
Reising AE, Godinho JM, Hormann K, Jorgenson JW, Tallarek U. Larger voids in mechanically stable, loose packings of 1.3μm frictional, cohesive particles: Their reconstruction, statistical analysis, and impact on separation efficiency. J Chromatogr A 2016; 1436:118-32. [PMID: 26858113 DOI: 10.1016/j.chroma.2016.01.068] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2015] [Revised: 01/21/2016] [Accepted: 01/24/2016] [Indexed: 12/23/2022]
Abstract
Lateral transcolumn heterogeneities and the presence of larger voids in a packing (comparable to the particle size) can limit the preparation of efficient chromatographic columns. Optimizing and understanding the packing process provides keys to better packing structures and column performance. Here, we investigate the slurry-packing process for a set of capillary columns packed with C18-modified, 1.3μm bridged-ethyl hybrid porous silica particles. The slurry concentration used for packing 75μm i.d. fused-silica capillaries was increased gradually from 5 to 50mg/mL. An intermediate concentration (20mg/mL) resulted in the best separation efficiency. Three capillaries from the set representing low, intermediate, and high slurry concentrations were further used for three-dimensional bed reconstruction by confocal laser scanning microscopy and morphological analysis of the bed structure. Previous studies suggest increased slurry concentrations will result in higher column efficiency due to the suppression of transcolumn bed heterogeneities, but only up to a critical concentration. Too concentrated slurries favour the formation of larger packing voids (reaching the size of the average particle diameter). Especially large voids, which can accommodate particles from>90% of the particle size distribution, are responsible for a decrease in column efficiency at high slurry concentrations. Our work illuminates the increasing difficulty of achieving high bed densities with small, frictional, cohesive particles. As particle size decreases interparticle forces become increasingly important and hinder the ease of particle sliding during column packing. While an optimal slurry concentration is identified with respect to bed morphology and separation efficiency under conditions in this work, our results suggest adjustments of this concentration are required with regard to particle size, surface roughness, column dimensions, slurry liquid, and external effects utilized during the packing process (pressure protocol, ultrasound, electric fields).
Collapse
Affiliation(s)
- Arved E Reising
- Department of Chemistry, Philipps-Universität Marburg, Hans-Meerwein-Strasse 4, 35032 Marburg, Germany
| | - Justin M Godinho
- Department of Chemistry, The University of North Carolina at Chapel Hill, Chapel Hill, NC 27599-3290, United States
| | - Kristof Hormann
- Department of Chemistry, Philipps-Universität Marburg, Hans-Meerwein-Strasse 4, 35032 Marburg, Germany
| | - James W Jorgenson
- Department of Chemistry, The University of North Carolina at Chapel Hill, Chapel Hill, NC 27599-3290, United States.
| | - Ulrich Tallarek
- Department of Chemistry, Philipps-Universität Marburg, Hans-Meerwein-Strasse 4, 35032 Marburg, Germany.
| |
Collapse
|
12
|
Highly efficient capillary columns packed with superficially porous particles via sequential column packing. J Chromatogr A 2015; 1422:345-349. [DOI: 10.1016/j.chroma.2015.10.013] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2015] [Revised: 10/02/2015] [Accepted: 10/06/2015] [Indexed: 01/20/2023]
|
13
|
Han J, Ye L, Xu L, Zhou Z, Gao F, Xiao Z, Wang Q, Zhang B. Towards high peak capacity separations in normal pressure nanoflow liquid chromatography using meter long packed capillary columns. Anal Chim Acta 2014; 852:267-73. [DOI: 10.1016/j.aca.2014.09.006] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2014] [Revised: 08/31/2014] [Accepted: 09/07/2014] [Indexed: 10/24/2022]
|
14
|
Effect of content of chiral selector and pore size of core–shell type silica support on the performance of amylose tris(3,5-dimethylphenylcarbamate)-based chiral stationary phases in nano-liquid chromatography and capillary electrochromatography. J Chromatogr A 2014; 1363:363-71. [DOI: 10.1016/j.chroma.2014.05.029] [Citation(s) in RCA: 48] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2014] [Revised: 05/06/2014] [Accepted: 05/11/2014] [Indexed: 11/19/2022]
|
15
|
Core–shell particles: Preparation, fundamentals and applications in high performance liquid chromatography. J Chromatogr A 2014; 1357:36-52. [DOI: 10.1016/j.chroma.2014.05.010] [Citation(s) in RCA: 311] [Impact Index Per Article: 31.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2014] [Revised: 05/01/2014] [Accepted: 05/02/2014] [Indexed: 11/23/2022]
|
16
|
Nano-liquid chromatography in nutraceutical analysis: Determination of polyphenols in bee pollen. J Chromatogr A 2013; 1313:270-4. [DOI: 10.1016/j.chroma.2013.06.055] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2013] [Revised: 06/19/2013] [Accepted: 06/20/2013] [Indexed: 01/09/2023]
|