1
|
Hu S, Ji J, Chen X, Tong R. Dielectrophoresis: Measurement technologies and auxiliary sensing applications. Electrophoresis 2024. [PMID: 38738705 DOI: 10.1002/elps.202300299] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2023] [Revised: 04/17/2024] [Accepted: 04/24/2024] [Indexed: 05/14/2024]
Abstract
Dielectrophoresis (DEP), which arises from the interaction between dielectric particles and an aqueous solution in a nonuniform electric field, contributes to the manipulation of nano and microparticles in many fields, including colloid physics, analytical chemistry, molecular biology, clinical medicine, and pharmaceutics. The measurement of the DEP force could provide a more complete solution for verifying current classical DEP theories. This review reports various imaging, fluidic, optical, and mechanical approaches for measuring the DEP forces at different amplitudes and frequencies. The integration of DEP technology into sensors enables fast response, high sensitivity, precise discrimination, and label-free detection of proteins, bacteria, colloidal particles, and cells. Therefore, this review provides an in-depth overview of DEP-based fabrication and measurements. Depending on the measurement requirements, DEP manipulation can be classified into assistance and integration approaches to improve sensor performance. To this end, an overview is dedicated to developing the concept of trapping-on-sensing, improving its structure and performance, and realizing fully DEP-assisted lab-on-a-chip systems.
Collapse
Affiliation(s)
- Sheng Hu
- College of Information Science and Engineering, Northeastern University, Shenyang, P. R. China
- Hebei Key Laboratory of Micro-Nano Precision Optical Sensing and Measurement Technology, Qinhuangdao, P. R. China
| | - Junyou Ji
- College of Information Science and Engineering, Northeastern University, Shenyang, P. R. China
| | - Xiaoming Chen
- College of Information Science and Engineering, Northeastern University, Shenyang, P. R. China
- Hebei Key Laboratory of Micro-Nano Precision Optical Sensing and Measurement Technology, Qinhuangdao, P. R. China
| | - Ruijie Tong
- College of Information Science and Engineering, Northeastern University, Shenyang, P. R. China
- Hebei Key Laboratory of Micro-Nano Precision Optical Sensing and Measurement Technology, Qinhuangdao, P. R. China
| |
Collapse
|
2
|
Farasat M, Aalaei E, Kheirati Ronizi S, Bakhshi A, Mirhosseini S, Zhang J, Nguyen NT, Kashaninejad N. Signal-Based Methods in Dielectrophoresis for Cell and Particle Separation. BIOSENSORS 2022; 12:510. [PMID: 35884313 PMCID: PMC9313092 DOI: 10.3390/bios12070510] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/15/2022] [Revised: 06/29/2022] [Accepted: 07/04/2022] [Indexed: 06/15/2023]
Abstract
Separation and detection of cells and particles in a suspension are essential for various applications, including biomedical investigations and clinical diagnostics. Microfluidics realizes the miniaturization of analytical devices by controlling the motion of a small volume of fluids in microchannels and microchambers. Accordingly, microfluidic devices have been widely used in particle/cell manipulation processes. Different microfluidic methods for particle separation include dielectrophoretic, magnetic, optical, acoustic, hydrodynamic, and chemical techniques. Dielectrophoresis (DEP) is a method for manipulating polarizable particles' trajectories in non-uniform electric fields using unique dielectric characteristics. It provides several advantages for dealing with neutral bioparticles owing to its sensitivity, selectivity, and noninvasive nature. This review provides a detailed study on the signal-based DEP methods that use the applied signal parameters, including frequency, amplitude, phase, and shape for cell/particle separation and manipulation. Rather than employing complex channels or time-consuming fabrication procedures, these methods realize sorting and detecting the cells/particles by modifying the signal parameters while using a relatively simple device. In addition, these methods can significantly impact clinical diagnostics by making low-cost and rapid separation possible. We conclude the review by discussing the technical and biological challenges of DEP techniques and providing future perspectives in this field.
Collapse
Affiliation(s)
- Malihe Farasat
- School of Electrical and Computer Engineering, College of Engineering, Tehran University, Tehran 14399-57131, Iran; (M.F.); (A.B.); (S.M.)
| | - Ehsan Aalaei
- School of Mechanical Engineering, Shiraz University, Shiraz 71936-16548, Iran; (E.A.); (S.K.R.)
| | - Saeed Kheirati Ronizi
- School of Mechanical Engineering, Shiraz University, Shiraz 71936-16548, Iran; (E.A.); (S.K.R.)
| | - Atin Bakhshi
- School of Electrical and Computer Engineering, College of Engineering, Tehran University, Tehran 14399-57131, Iran; (M.F.); (A.B.); (S.M.)
| | - Shaghayegh Mirhosseini
- School of Electrical and Computer Engineering, College of Engineering, Tehran University, Tehran 14399-57131, Iran; (M.F.); (A.B.); (S.M.)
| | - Jun Zhang
- Queensland Micro-Nanotechnology Centre, Griffith University, Nathan, QLD 4111, Australia; (J.Z.); (N.-T.N.)
| | - Nam-Trung Nguyen
- Queensland Micro-Nanotechnology Centre, Griffith University, Nathan, QLD 4111, Australia; (J.Z.); (N.-T.N.)
| | - Navid Kashaninejad
- Queensland Micro-Nanotechnology Centre, Griffith University, Nathan, QLD 4111, Australia; (J.Z.); (N.-T.N.)
| |
Collapse
|
3
|
Rashid NFA, Deivasigamani R, Wee MFMR, Hamzah AA, Buyong MR. Integration of a Dielectrophoretic Tapered Aluminum Microelectrode Array with a Flow Focusing Technique. SENSORS 2021; 21:s21154957. [PMID: 34372193 PMCID: PMC8347692 DOI: 10.3390/s21154957] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/04/2021] [Revised: 06/24/2021] [Accepted: 07/07/2021] [Indexed: 12/12/2022]
Abstract
We present the integration of a flow focusing microfluidic device in a dielectrophoretic application that based on a tapered aluminum microelectrode array (TAMA). The characterization and optimization method of microfluidic geometry performs the hydrodynamic flow focusing on the channel. The sample fluids are hydrodynamically focused into the region of interest (ROI) where the dielectrophoresis force (FDEP) is dominant. The device geometry is designed using 3D CAD software and fabricated using the micro-milling process combined with soft lithography using PDMS. The flow simulation is achieved using COMSOL Multiphysics 5.5 to study the effect of the flow rate ratio between the sample fluids (Q1) and the sheath fluids (Q2) toward the width of flow focusing. Five different flow rate ratios (Q1/Q2) are recorded in this experiment, which are 0.2, 0.4, 0.6, 0.8 and 1.0. The width of flow focusing is increased linearly with the flow rate ratio (Q1/Q2) for both the simulation and the experiment. At the highest flow rate ratio (Q1/Q2 = 1), the width of flow focusing is obtained at 638.66 µm and at the lowest flow rate ratio (Q1/Q2 = 0.2), the width of flow focusing is obtained at 226.03 µm. As a result, the flow focusing effect is able to reduce the dispersion of the particles in the microelectrode from 2000 µm to 226.03 µm toward the ROI. The significance of flow focusing on the separation of particles is studied using 10 and 1 µm polystyrene beads by applying a non-uniform electrical field to the TAMA at 10 VPP, 150 kHz. Ultimately, we are able to manipulate the trajectories of two different types of particles in the channel. For further validation, the focusing of 3.2 µm polystyrene beads within the dominant FDEP results in an enhanced manipulation efficiency from 20% to 80% in the ROI.
Collapse
|
4
|
Ertugrul I, Ulkir O. Dielectrophoretic separation of platelet cells in a microfluidic channel and optimization with fuzzy logic. RSC Adv 2020; 10:33731-33738. [PMID: 35519028 PMCID: PMC9056726 DOI: 10.1039/d0ra06271e] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2020] [Accepted: 08/29/2020] [Indexed: 12/17/2022] Open
Abstract
It is the aim to develop optimization techniques to separate platelets from Red Blood Cells (RBCs) after designing and analyzing a microfluidic chip in this study. RBCs and platelets are present in the blood, but some healthcare applications require either platelets or RBCs. Therefore, it is necessary to separate platelets from RBCs. In this study, the design and analysis of the microfluidic chip were carried out with the Comsol Multiphysics program. Since the separation of platelets and RBCs in the blood flowing from a channel is provided by the Dielectrophoretic (DEP) force technique, the DEP force feature was given importance in the design of microfluidic channels. Much data was obtained while designing and analyzing processes. It has been observed that the voltage applied to the microfluidic channel and the inlet velocity of the blood affect the fluidic velocity and pressure along the microfluidic channel. It was also understood that the separation of platelets from RBCs depends on input data. Input and output data were analyzed in the Comsol Multiphysics program, and the optimization of the microfluidic chip was realized with the Matlab-Fuzzy Logic program. In order for the platelets to be separated from the RBCs, the optimum voltage to be applied to the microfluidic chip should be in the range of 4–6 V and the inlet velocity of the blood in the range of 800–900 μm s−1. When these input values are given, the maximum pressure affecting the microfluidic outlet channel is 10–12 Pa, and the maximum velocity is in the range of 1.25–1.5 mm s−1. These results are the optimum values required to separate platelets from RBCs. It is the aim to develop optimization techniques to separate platelets from Red Blood Cells (RBCs) after designing and analyzing a microfluidic chip in this study.![]()
Collapse
Affiliation(s)
- Ishak Ertugrul
- Department of Mechatronics, University of Mus Alparslan Mus 49100 Turkey
| | - Osman Ulkir
- Department of Electronics and Automation, University of Mus Alparslan Mus 49100 Turkey
| |
Collapse
|
5
|
High-Sensitivity in Dielectrophoresis Separations. MICROMACHINES 2020; 11:mi11040391. [PMID: 32283618 PMCID: PMC7231031 DOI: 10.3390/mi11040391] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/19/2020] [Revised: 03/19/2020] [Accepted: 03/26/2020] [Indexed: 01/27/2023]
Abstract
The applications of dielectrophoretic (DEP) techniques for the manipulation of cells in a label-free fashion within microfluidic systems continue to grow. However, a limited number of methods exist for making highly sensitive separations that can isolate subtle phenotypic differences within a population of cells. This paper explores efforts to leverage that most compelling aspect of DEP—an actuation force that depends on particle electrical properties—in the background of phenotypic variations in cell size. Several promising approaches, centering around the application of multiple electric fields with spatially mapped magnitude and/or frequencies, are expanding the capability of DEP cell separation.
Collapse
|
6
|
Liang W, Liu L, Wang J, Yang X, Wang Y, Li WJ, Yang W. A Review on Optoelectrokinetics-Based Manipulation and Fabrication of Micro/Nanomaterials. MICROMACHINES 2020; 11:mi11010078. [PMID: 31936694 PMCID: PMC7019850 DOI: 10.3390/mi11010078] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/20/2019] [Revised: 01/07/2020] [Accepted: 01/08/2020] [Indexed: 12/20/2022]
Abstract
Optoelectrokinetics (OEK), a fusion of optics, electrokinetics, and microfluidics, has been demonstrated to offer a series of extraordinary advantages in the manipulation and fabrication of micro/nanomaterials, such as requiring no mask, programmability, flexibility, and rapidness. In this paper, we summarize a variety of differently structured OEK chips, followed by a discussion on how they are fabricated and the ways in which they work. We also review how three differently sized polystyrene beads can be separated simultaneously, how a variety of nanoparticles can be assembled, and how micro/nanomaterials can be fabricated into functional devices. Another focus of our paper is on mask-free fabrication and assembly of hydrogel-based micro/nanostructures and its possible applications in biological fields. We provide a summary of the current challenges facing the OEK technique and its future prospects at the end of this paper.
Collapse
Affiliation(s)
- Wenfeng Liang
- School of Mechanical Engineering, Shenyang Jianzhu University, Shenyang 110168, China; (W.L.); (J.W.); (X.Y.)
| | - Lianqing Liu
- State Key Laboratory of Robotics, Shenyang Institute of Automation, Chinese Academy of Sciences, Shenyang 110016, China;
- CAS-CityU Joint Laboratory on Robotics, City University of Hong Kong, Kowloon Tong, Hong Kong 999077, China
- Correspondence: (L.L.); (W.J.L.); Tel.: +86-24-2397-0181 (L.L.); +852-3442-9266 (W.J.L.)
| | - Junhai Wang
- School of Mechanical Engineering, Shenyang Jianzhu University, Shenyang 110168, China; (W.L.); (J.W.); (X.Y.)
| | - Xieliu Yang
- School of Mechanical Engineering, Shenyang Jianzhu University, Shenyang 110168, China; (W.L.); (J.W.); (X.Y.)
| | - Yuechao Wang
- State Key Laboratory of Robotics, Shenyang Institute of Automation, Chinese Academy of Sciences, Shenyang 110016, China;
- CAS-CityU Joint Laboratory on Robotics, City University of Hong Kong, Kowloon Tong, Hong Kong 999077, China
| | - Wen Jung Li
- CAS-CityU Joint Laboratory on Robotics, City University of Hong Kong, Kowloon Tong, Hong Kong 999077, China
- Department of Mechanical Engineering, City University of Hong Kong, Kowloon Tong, Hong Kong 999077, China
- Correspondence: (L.L.); (W.J.L.); Tel.: +86-24-2397-0181 (L.L.); +852-3442-9266 (W.J.L.)
| | - Wenguang Yang
- School of Electromechanical and Automotive Engineering, Yantai University, Yantai 264005, China;
| |
Collapse
|