Sani A, Tian Y, Zha G, Xiao X, Shah S, Idrees Khan M, Fan L, Zhang Q, Liu W, Wang Y, Chen P, Cao C. A high stable sample loading for analysis of adult alpha-thalassemia via the improved microarray isoelectric focusing of Hb species. J Chromatogr B Analyt Technol Biomed Life Sci 2024; 1244:124238. [PMID: 39018990 DOI: 10.1016/j.jchromb.2024.124238] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2024] [Revised: 06/27/2024] [Accepted: 07/08/2024] [Indexed: 07/19/2024]
Abstract
The isoelectric focusing has realized various improvements, including the protocols and creation of mIEF (microcolumn isoelectric focusing) instruments with excellent sensitivity for screening of diabetes and beta thalassemia. However, the problem of manual sample loading and hydration for the mIEF limits the operational capacity for stably detecting and quantitating most abnormal hemoglobin (Hb). Herein, we provided a high stable sample loading protocol for analysis of alpha thalassemia and Hb variants. In contrast to the previous volume of 20 μl, a 100 µl blood sample solution in this protocol was optimized with mixture of 6.4-7.5 and 3-10 pH carrier ampholytes, pI markers and loaded for 30 mins IPG microcolumn hydration. The hydrated microcolumn was then automatically loaded onto the mIEF chip array to which CH3COOH and NH4OH act as anodic and cathodic solutions. Lastly, the IEF was run for 9 mins. Hb H, Barts, A1c, F, A2 and CS were simultaneously separated and focused with higher resolution and sensitivity in quantifying H and Barts as low as 0.6 and 0.5 % respectively. Accordingly, there was an enhanced stability and linearity with a rapid assay time of 45 secs per sample. Moreover, analysis showed a fitting linear relationship with conventional technology at R2 = 0.9803 for H and R2 = 0.9728 for Barts thereby indicating greater accuracy confirmed by the AUC. Hence, the developed protocol could simply be employed for high stable and throughput batch sample loading of hydration, and accurate separation and quantitation of Hb variants for alpha and beta thalassemia.
Collapse
Affiliation(s)
- Ali Sani
- School of Sensing Science and Engineering, School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai 200240, China
| | - Youli Tian
- School of Sensing Science and Engineering, School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai 200240, China
| | - Genhan Zha
- School of Sensing Science and Engineering, School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai 200240, China
| | - Xuan Xiao
- NHC Key Laboratory of Thalassemia Medicine, Key Laboratory of Thalassemia Medicine, Chinese Academy of Medical Sciences, Guangxi Key Laboratory of Thalassemia Research, Guangxi Medical University, Nanning 530021, PR China
| | - Saud Shah
- School of Sensing Science and Engineering, School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai 200240, China
| | - Muhammad Idrees Khan
- School of Sensing Science and Engineering, School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai 200240, China
| | - Liuyin Fan
- Student Innovation Center, Shanghai Jiao Tong University, Shanghai 200240, China
| | - Qiang Zhang
- School of Sensing Science and Engineering, School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai 200240, China
| | - Weiwen Liu
- School of Sensing Science and Engineering, School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai 200240, China
| | - Yuxin Wang
- School of Physics and Astronomy, Shanghai Jiao Tong University, Shanghai 200240, China.
| | - Ping Chen
- NHC Key Laboratory of Thalassemia Medicine, Key Laboratory of Thalassemia Medicine, Chinese Academy of Medical Sciences, Guangxi Key Laboratory of Thalassemia Research, Guangxi Medical University, Nanning 530021, PR China.
| | - Chengxi Cao
- School of Sensing Science and Engineering, School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai 200240, China.
| |
Collapse
|
2
|
Krebs F, Zagst H, Stein M, Ratih R, Minkner R, Olabi M, Hartung S, Scheller C, Lapizco-Encinas BH, Sänger-van de Griend C, García CD, Wätzig H. Strategies for capillary electrophoresis: Method development and validation for pharmaceutical and biological applications-Updated and completely revised edition. Electrophoresis 2023; 44:1279-1341. [PMID: 37537327 DOI: 10.1002/elps.202300158] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2023] [Accepted: 07/19/2023] [Indexed: 08/05/2023]
Abstract
This review is in support of the development of selective, precise, fast, and validated capillary electrophoresis (CE) methods. It follows up a similar article from 1998, Wätzig H, Degenhardt M, Kunkel A. "Strategies for capillary electrophoresis: method development and validation for pharmaceutical and biological applications," pointing out which fundamentals are still valid and at the same time showing the enormous achievements in the last 25 years. The structures of both reviews are widely similar, in order to facilitate their simultaneous use. Focusing on pharmaceutical and biological applications, the successful use of CE is now demonstrated by more than 600 carefully selected references. Many of those are recent reviews; therefore, a significant overview about the field is provided. There are extra sections about sample pretreatment related to CE and microchip CE, and a completely revised section about method development for protein analytes and biomolecules in general. The general strategies for method development are summed up with regard to selectivity, efficiency, precision, analysis time, limit of detection, sample pretreatment requirements, and validation.
Collapse
Affiliation(s)
- Finja Krebs
- Institute, of Medicinal and Pharmaceutical Chemistry, Technische Universität Braunschweig, Braunschweig, Lower Saxony, Germany
| | - Holger Zagst
- Institute, of Medicinal and Pharmaceutical Chemistry, Technische Universität Braunschweig, Braunschweig, Lower Saxony, Germany
| | - Matthias Stein
- Institute, of Medicinal and Pharmaceutical Chemistry, Technische Universität Braunschweig, Braunschweig, Lower Saxony, Germany
| | - Ratih Ratih
- Department of Pharmaceutical Chemistry, Faculty of Pharmacy, University of Surabaya, Surabaya, East Java, Indonesia
| | - Robert Minkner
- Institute, of Medicinal and Pharmaceutical Chemistry, Technische Universität Braunschweig, Braunschweig, Lower Saxony, Germany
| | - Mais Olabi
- Institute, of Medicinal and Pharmaceutical Chemistry, Technische Universität Braunschweig, Braunschweig, Lower Saxony, Germany
| | - Sophie Hartung
- Institute, of Medicinal and Pharmaceutical Chemistry, Technische Universität Braunschweig, Braunschweig, Lower Saxony, Germany
| | - Christin Scheller
- Institute, of Medicinal and Pharmaceutical Chemistry, Technische Universität Braunschweig, Braunschweig, Lower Saxony, Germany
| | - Blanca H Lapizco-Encinas
- Department of Biomedical Engineering, Kate Gleason College of Engineering, Rochester Institute of Technology, Rochester, New York, USA
| | - Cari Sänger-van de Griend
- Kantisto BV, Baarn, The Netherlands
- Department of Medicinal Chemistry, Faculty of Pharmacy, Uppsala Universitet, Uppsala, Sweden
| | - Carlos D García
- Department of Chemistry, Clemson University, Clemson, South Carolina, USA
| | - Hermann Wätzig
- Institute, of Medicinal and Pharmaceutical Chemistry, Technische Universität Braunschweig, Braunschweig, Lower Saxony, Germany
| |
Collapse
|
3
|
Abbood A. Optimization of the Imaged cIEF Method for Monitoring the Charge Heterogeneity of Antibody-Maytansine Conjugate. JOURNAL OF ANALYTICAL METHODS IN CHEMISTRY 2023; 2023:8150143. [PMID: 37305029 PMCID: PMC10256444 DOI: 10.1155/2023/8150143] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/19/2022] [Revised: 11/14/2022] [Accepted: 05/23/2023] [Indexed: 06/13/2023]
Abstract
The aim of this study was to develop a whole-column imaging-detection capillary isoelectric focusing (icIEF) method for the analytical characterization of charge heterogeneity of a novel humanized anti-EphA2 antibody conjugated to a maytansine derivative. In addition to focusing time, sample composition was optimized: pH range, percent of carrier ampholytes, conjugated antibody concentration, and urea concentration. A good separation of charge isoforms was obtained with 4% carrier ampholytes of a large (3-10) and narrow pH range (8-10.5) (1 : 1 ratio), conjugated antibody concentration (0.3-1 mg/ml) with a good linearity (R2: 0.9905), 2 M of urea concentration, and 12 minute for focusing. The optimized icIEF method demonstrated a good interday repeatability with RSD values: <1% (pI), <8% (% peak area), and 7% (total peak areas). The optimized icIEF was useful as an analytical characterization tool to assess the charged isoform profile of a discovery batch of the studied maytansinoid-antibody conjugate in comparison to its naked antibody. It exhibited a large pI range (7.5-9.0), while its naked antibody showed a narrow pI range (8.9-9.0). In the discovery batch of maytansinoid-antibody conjugate, 2% of charge isoforms had the same pI as the pI of naked antibody isoforms.
Collapse
Affiliation(s)
- Ayat Abbood
- Department of Medicinal Chemistry and Quality Control, Faculty of Pharmacy, Tishreen University, Lattakia, Syria
| |
Collapse
|
4
|
Tardif C, Jaccoulet E, Bellec JF, Surroca Y, Talbot L, Taverna M, Smadja C. Imaged capillary isoelectric focusing associated with multivariate analysis: A powerful tool for quality control of therapeutic monoclonal antibodies. Talanta 2023; 260:124633. [PMID: 37172435 DOI: 10.1016/j.talanta.2023.124633] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2023] [Revised: 04/28/2023] [Accepted: 05/02/2023] [Indexed: 05/15/2023]
Abstract
Monoclonal antibodies are increasingly used in cancer therapy. To guarantee the quality of these mAbs from compounding to patient administration, characterization methods are required (e.g. identity). In a clinical setting, these methods must be fast and straightforward. For this reason, we investigated the potential of image capillary isoelectric focusing (icIEF) combined with Principal Component Analysis (PCA) and Partial least squares-discriminant analysis (PLS-DA). icIEF profiles obtained from monoclonals antibodies (mAbs) analysis have been pre-processed and the data submitted to principal component analysis (PCA). This pre-processing method has been designed to avoid the impact of concentration and formulation. Analysis of four commercialized mAbs (Infliximab, Nivolumab, Pertuzumab, and Adalimumab) by icIEF-PCA led to the formation of four clusters corresponding to each mAb. Partial least squares-discriminant analysis (PLS-DA) applied to these data allowed us to build models to predict which monoclonal antibody is analyzed. The validation of this model was obtained from k-fold cross-validation and prediction tests. The selectivity and the specificity of the model performance parameters were assessed by the excellent classification obtained. In conclusion, we established that the combination of icIEF and chemometric approaches is a reliable approach for unambiguously identifying compounded therapeutic monoclonal antibodies (mAbs) before patient administration.
Collapse
Affiliation(s)
- Cécile Tardif
- Institut Galien Paris Saclay, Université Paris-Saclay, CNRS UMR 8612, Protein and Nanotechnology in Analytical Science (PNAS), 17 Avenue des Sciences, 91300, Orsay, France
| | | | - Jean-François Bellec
- Biotechne France, 19 Rue Louis Delourmel, 35230, Noyal-Châtillon-sur-Seiche, France
| | - Yannick Surroca
- Biotechne France, 19 Rue Louis Delourmel, 35230, Noyal-Châtillon-sur-Seiche, France
| | - Laurence Talbot
- Biotechne France, 19 Rue Louis Delourmel, 35230, Noyal-Châtillon-sur-Seiche, France
| | - Myriam Taverna
- Institut Galien Paris Saclay, Université Paris-Saclay, CNRS UMR 8612, Protein and Nanotechnology in Analytical Science (PNAS), 17 Avenue des Sciences, 91300, Orsay, France; Institut Universitaire de France, 103 Boulevard Saint Michel, 75005, Paris, France
| | - Claire Smadja
- Institut Galien Paris Saclay, Université Paris-Saclay, CNRS UMR 8612, Protein and Nanotechnology in Analytical Science (PNAS), 17 Avenue des Sciences, 91300, Orsay, France.
| |
Collapse
|
5
|
Štěpánová S, Kašička V. Applications of capillary electromigration methods for separation and analysis of proteins (2017–mid 2021) – A review. Anal Chim Acta 2022; 1209:339447. [DOI: 10.1016/j.aca.2022.339447] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2021] [Revised: 01/04/2022] [Accepted: 01/04/2022] [Indexed: 12/11/2022]
|