1
|
Berg AB, Ferreira Santos MS, Bautista A, Mora MF, Pauken MT, Noell AC. Development of a capillary temperature control system for capillary electrophoresis instruments designed for spaceflight applications. Electrophoresis 2024; 45:1495-1504. [PMID: 38687164 DOI: 10.1002/elps.202300254] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2023] [Revised: 04/08/2024] [Accepted: 04/10/2024] [Indexed: 05/02/2024]
Abstract
Capillary temperature control during capillary electrophoresis (CE) separations is key for achieving accurate and reproducible results with a broad array of potential methods. However, the difficulty of enabling typical fluid temperature control loops on portable instruments has meant that active capillary temperature control of in situ CE systems has frequently been overlooked. This work describes construction and test of a solid-state device for capillary temperature control that is suitable for inclusion with in situ instruments, including those designed for space missions. Two test articles were built, a thermal mass model (TMM) and a functional model (FM). The TMM demonstrated that temperature gradients could be limited using the proposed control scheme, and that our thermal modeling of the system can be relied on for future adaptations of physical geometries of the system. The FM demonstrated CE analytical performance while under active temperature control and that the device was compatible with the harsh thermal-vacuum environments that might be encountered during space flight.
Collapse
Affiliation(s)
- Andrew B Berg
- NASA Jet Propulsion Laboratory, California Institute of Technology, Pasadena, California, USA
| | - Mauro S Ferreira Santos
- NASA Jet Propulsion Laboratory, California Institute of Technology, Pasadena, California, USA
| | - Anthony Bautista
- NASA Jet Propulsion Laboratory, California Institute of Technology, Pasadena, California, USA
| | - Maria F Mora
- NASA Jet Propulsion Laboratory, California Institute of Technology, Pasadena, California, USA
| | - Michael T Pauken
- NASA Jet Propulsion Laboratory, California Institute of Technology, Pasadena, California, USA
| | - Aaron C Noell
- NASA Jet Propulsion Laboratory, California Institute of Technology, Pasadena, California, USA
| |
Collapse
|
2
|
Wallace ML, Tallarida N, Schubert WW, Lambert J. Life Detection on Icy Moons Using Flow Cytometry and Exogenous Fluorescent Stains. ASTROBIOLOGY 2023; 23:1071-1082. [PMID: 37672625 DOI: 10.1089/ast.2023.0016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/08/2023]
Abstract
Flow cytometry is a potential technology for in situ life detection on icy moons (such as Enceladus and Europa) and on the polar ice caps of Mars. We developed a method for using flow cytometry to positively identify four classes of biomarkers using exogenous fluorescent stains: nucleic acids, proteins, carbohydrates, and lipids. We demonstrated the effectiveness of exogenous stains with six known organisms and known abiotic material and showed that the cytometer is easily able to distinguish between the known organisms and the known abiotic material using the exogenous stains. To simulate a life-detection experiment on an icy world lander, we used six natural samples with unknown biotic and abiotic content. We showed that flow cytometry can identify all four biomarkers using the exogenous stains and can separate the biotic material from the known abiotic material on scatter plots. Exogenous staining techniques would likely be used in conjunction with intrinsic fluorescence, clustering, and sorting for a more complete and capable life-detection instrument on an icy moon lander.
Collapse
Affiliation(s)
- Matthew L Wallace
- Jet Propulsion Laboratory, California Institute of Technology, Pasadena, California, USA
| | - Nicholas Tallarida
- Jet Propulsion Laboratory, California Institute of Technology, Pasadena, California, USA
| | - Wayne W Schubert
- Jet Propulsion Laboratory, California Institute of Technology, Pasadena, California, USA
| | - James Lambert
- Jet Propulsion Laboratory, California Institute of Technology, Pasadena, California, USA
| |
Collapse
|
3
|
Krebs F, Zagst H, Stein M, Ratih R, Minkner R, Olabi M, Hartung S, Scheller C, Lapizco-Encinas BH, Sänger-van de Griend C, García CD, Wätzig H. Strategies for capillary electrophoresis: Method development and validation for pharmaceutical and biological applications-Updated and completely revised edition. Electrophoresis 2023; 44:1279-1341. [PMID: 37537327 DOI: 10.1002/elps.202300158] [Citation(s) in RCA: 9] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2023] [Accepted: 07/19/2023] [Indexed: 08/05/2023]
Abstract
This review is in support of the development of selective, precise, fast, and validated capillary electrophoresis (CE) methods. It follows up a similar article from 1998, Wätzig H, Degenhardt M, Kunkel A. "Strategies for capillary electrophoresis: method development and validation for pharmaceutical and biological applications," pointing out which fundamentals are still valid and at the same time showing the enormous achievements in the last 25 years. The structures of both reviews are widely similar, in order to facilitate their simultaneous use. Focusing on pharmaceutical and biological applications, the successful use of CE is now demonstrated by more than 600 carefully selected references. Many of those are recent reviews; therefore, a significant overview about the field is provided. There are extra sections about sample pretreatment related to CE and microchip CE, and a completely revised section about method development for protein analytes and biomolecules in general. The general strategies for method development are summed up with regard to selectivity, efficiency, precision, analysis time, limit of detection, sample pretreatment requirements, and validation.
Collapse
Affiliation(s)
- Finja Krebs
- Institute, of Medicinal and Pharmaceutical Chemistry, Technische Universität Braunschweig, Braunschweig, Lower Saxony, Germany
| | - Holger Zagst
- Institute, of Medicinal and Pharmaceutical Chemistry, Technische Universität Braunschweig, Braunschweig, Lower Saxony, Germany
| | - Matthias Stein
- Institute, of Medicinal and Pharmaceutical Chemistry, Technische Universität Braunschweig, Braunschweig, Lower Saxony, Germany
| | - Ratih Ratih
- Department of Pharmaceutical Chemistry, Faculty of Pharmacy, University of Surabaya, Surabaya, East Java, Indonesia
| | - Robert Minkner
- Institute, of Medicinal and Pharmaceutical Chemistry, Technische Universität Braunschweig, Braunschweig, Lower Saxony, Germany
| | - Mais Olabi
- Institute, of Medicinal and Pharmaceutical Chemistry, Technische Universität Braunschweig, Braunschweig, Lower Saxony, Germany
| | - Sophie Hartung
- Institute, of Medicinal and Pharmaceutical Chemistry, Technische Universität Braunschweig, Braunschweig, Lower Saxony, Germany
| | - Christin Scheller
- Institute, of Medicinal and Pharmaceutical Chemistry, Technische Universität Braunschweig, Braunschweig, Lower Saxony, Germany
| | - Blanca H Lapizco-Encinas
- Department of Biomedical Engineering, Kate Gleason College of Engineering, Rochester Institute of Technology, Rochester, New York, USA
| | - Cari Sänger-van de Griend
- Kantisto BV, Baarn, The Netherlands
- Department of Medicinal Chemistry, Faculty of Pharmacy, Uppsala Universitet, Uppsala, Sweden
| | - Carlos D García
- Department of Chemistry, Clemson University, Clemson, South Carolina, USA
| | - Hermann Wätzig
- Institute, of Medicinal and Pharmaceutical Chemistry, Technische Universität Braunschweig, Braunschweig, Lower Saxony, Germany
| |
Collapse
|
4
|
Ferreira Santos MS, Kurfman E, Zamuruyev K, Noell AC, Mora MF, Willis PA. A voltage trade study for the design of capillary electrophoresis instruments for spaceflight. Electrophoresis 2023; 44:10-14. [PMID: 35569140 DOI: 10.1002/elps.202200085] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2022] [Revised: 04/29/2022] [Accepted: 05/06/2022] [Indexed: 02/01/2023]
Abstract
Capillary electrophoresis (CE) systems have undergone extensive development for spaceflight applications. A flight-compatible high voltage power supply and the necessary voltage isolation for other energized components can be large contributors to both the volume and mass of a CE system, especially if typical high voltage levels of 25-30 kV are used. Here, we took advantage of our custom CE hardware to perform a trade study for simultaneous optimization of capillary length, high voltage level, and separation time, without sacrificing method performance. A capillary electrophoresis with capacitively coupled contactless conductivity detection (CE-C4 D) method recently developed by our group to target inorganic cations and amino acids relevant to astrobiology was used as a test case. The results indicate that a 50 cm long capillary with 15 kV applied voltage (half of that used in the original method) can be used to achieve measurement goals while minimizing instrument size.
Collapse
Affiliation(s)
| | - Emily Kurfman
- Department of Chemistry, University of Kansas, Lawrence, Kansas, USA
- Ralph N. Adams Institute for Bioanalytical Chemistry, University of Kansas, Lawrence, Kansas, USA
| | - Konstantin Zamuruyev
- Jet Propulsion Laboratory, California Institute of Technology, Pasadena, California, USA
| | - Aaron C Noell
- Jet Propulsion Laboratory, California Institute of Technology, Pasadena, California, USA
| | - Maria F Mora
- Jet Propulsion Laboratory, California Institute of Technology, Pasadena, California, USA
| | - Peter A Willis
- Jet Propulsion Laboratory, California Institute of Technology, Pasadena, California, USA
| |
Collapse
|
5
|
Van Volkenburg T, Benzing JS, Craft KL, Ohiri K, Kilhefner A, Irons K, Bradburne C. Microfluidic Chromatography for Enhanced Amino Acid Detection at Ocean Worlds. ASTROBIOLOGY 2022; 22:1116-1128. [PMID: 35984944 PMCID: PMC9508454 DOI: 10.1089/ast.2021.0182] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/12/2021] [Accepted: 04/18/2022] [Indexed: 06/15/2023]
Abstract
Increasing interest in the detection of biogenic signatures, such as amino acids, on icy moons and bodies within our solar system has led to the development of compact in situ instruments. Given the expected dilute biosignatures and high salinities of these extreme environments, purification of icy samples before analysis enables increased detection sensitivity. Herein, we outline a novel compact cation exchange method to desalinate proteinogenic amino acids in solution, independent of the type and concentration of salts in the sample. Using a modular microfluidic device, initial experiments explored operational limits of binding capacity with phenylalanine and three model cations, Na+, Mg2+, and Ca2+. Phenylalanine recovery (94-17%) with reduced conductivity (30-200 times) was seen at high salt-to-amino-acid ratios between 25:1 and 500:1. Later experiments tested competition between mixtures of 17 amino acids and other chemistries present in a terrestrial ocean sample. Recoveries ranged from 11% to 85% depending on side chain chemistry and cation competition, with concentration shown for select high affinity amino acids. This work outlines a nondestructive amino acid purification device capable of coupling to multiple downstream analytical techniques for improved characterization of icy samples at remote ocean worlds.
Collapse
Affiliation(s)
| | | | - Kathleen L. Craft
- Johns Hopkins University Applied Physics Laboratory, Laurel, Maryland, USA
| | - Korine Ohiri
- Johns Hopkins University Applied Physics Laboratory, Laurel, Maryland, USA
| | - Ashley Kilhefner
- Johns Hopkins University Applied Physics Laboratory, Laurel, Maryland, USA
| | - Kristen Irons
- University of North Carolina at Chapel Hill College of Arts and Sciences, Chapel Hill, North Carolina, USA
| | | |
Collapse
|
6
|
Mora MF, Kok MGM, Noell A, Willis PA. Detection of Biosignatures by Capillary Electrophoresis Mass Spectrometry in the Presence of Salts Relevant to Ocean Worlds Missions. ASTROBIOLOGY 2022; 22:914-925. [PMID: 35913998 DOI: 10.1089/ast.2021.0091] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Capillary electrophoresis (CE) is a promising liquid-based technique for in situ chemical analysis on ocean worlds that allows the detection of a wide range of organic molecules relevant to the search for life. CE coupled with mass spectrometry (MS) is particularly valuable as it also enables the discovery of unknown compounds. Here we demonstrate that CE coupled to MS via electrospray ionization (ESI) can readily analyze samples containing up to half the saturation levels of salts relevant to ocean worlds when using 5 M acetic acid as the separation media. A mixture containing amino acids, peptides, nucleobases, and nucleosides was analyzed in the presence of two salts, NaCl and MgSO4, based on their relevance to Europa and Enceladus. We demonstrate here CE-MS limits of detection for these organics ranging from 0.05 to 1 μM (8 to 89 ppb) in the absence of salts. More importantly, we demonstrate here for the first time that organics in the low micromolar range (1-50 μM) are detected by CE-MS in the presence of 3 M NaCl without desalting, preconcentration, or derivatization. This demonstration highlights how CE-MS is uniquely suited for organic analysis on future missions to ocean worlds.
Collapse
Affiliation(s)
- Maria F Mora
- Jet Propulsion Laboratory, California Institute of Technology, Pasadena, California, USA
| | - Miranda G M Kok
- Jet Propulsion Laboratory, California Institute of Technology, Pasadena, California, USA
| | - Aaron Noell
- Jet Propulsion Laboratory, California Institute of Technology, Pasadena, California, USA
| | - Peter A Willis
- Jet Propulsion Laboratory, California Institute of Technology, Pasadena, California, USA
| |
Collapse
|