1
|
Picone M, Delaney E, Tagliapietra D, Guarneri I, Volpi Ghirardini A. Bioaccumulation of Polychlorinated Dibenzo-p-Dioxins (PCDDs) and Dibenzofurans (PCDFs) in Hediste diversicolor (Polychaeta: Nereididae). Front Ecol Evol 2020. [DOI: 10.3389/fevo.2020.00235] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
|
2
|
Ito K, Ito M, Onduka T, Ohta K, Torii T, Hano T, Mochida K, Ohkubo N, Miura T, Fujii K. Differences in the ability of two marine annelid species, Thalassodrilides sp. and Perinereis nuntia, to detoxify 1-nitronaphthalene. CHEMOSPHERE 2016; 151:339-344. [PMID: 26950025 DOI: 10.1016/j.chemosphere.2016.02.026] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/10/2015] [Revised: 01/06/2016] [Accepted: 02/06/2016] [Indexed: 06/05/2023]
Abstract
Bioremediation is a promising method for remediating environmentally polluted water. We investigated the abilities of two benthic annelid species to biotransform 1-nitronaphthalene, a nitrated polycyclic aromatic hydrocarbon. We used an oligochaete, Thalassodrilides sp. (Naididae), collected from the sediment beneath a fish farm and a polychaete, Perinereis nuntia, which was obtained from a commercial source. Populations of both organisms were exposed to 1400 μg L(-1) of 1-nitronaphthalene in seawater for 3 days in the dark at 20 °C. The concentration of the pollutant decreased to 12 μg L(-1) in the seawater containing the Thalassodrilides sp. and to 560 μg L(-1) in the seawater containing P. nuntia. The 1-nitronaphthalene concentration in the bodies of the animals increased from 12 to 94 μg kg(-1) in Thalassodrilides sp. and from 0.90 μg kg(-1) to 38,000 μg kg(-1) in P. nuntia. After 3 days, 99% and 40% of the 1-nitronaphthalene had been biotransformed in the Thalassodrilides sp. and P. nuntia experimental groups, respectively. We then tested the acute toxicity of residual 1-nitronaphthalene from the same water using mummichog (fish) larvae. After the larvae had been exposed for 96 h, the percentage of apparently unaffected larvae remaining was 83.3% in Thalassodrilides sp. group but only 16.7% in the P. nuntia group. Clearly, of the two species we studied, Thalassodrilides sp. had a superior ability to convert 1-nitronaphthalene into substances that were nontoxic to mummichog larvae. Therefore, we recommend the use of this species for bioremediation of chemically polluted sediments.
Collapse
Affiliation(s)
- Katsutoshi Ito
- National Research Institute of Fisheries and Environment of Inland Sea, Fisheries Research Agency, 2-17-5, Maruishi, Hatsukaichi, Hiroshima 739-0452, Japan.
| | - Mana Ito
- National Research Institute of Fisheries and Environment of Inland Sea, Fisheries Research Agency, 2-17-5, Maruishi, Hatsukaichi, Hiroshima 739-0452, Japan
| | - Toshimitsu Onduka
- National Research Institute of Fisheries and Environment of Inland Sea, Fisheries Research Agency, 2-17-5, Maruishi, Hatsukaichi, Hiroshima 739-0452, Japan
| | - Kohei Ohta
- South Ehime Fisheries Research Center, Ehime University, 1289-1, Funakoshi, Ainan, Ehime 798-4292, Japan
| | - Takaaki Torii
- IDEA Consultants Inc., 1334-5, Riemon, Yaizu-shi, Shizuoka 421-0212, Japan
| | - Takeshi Hano
- National Research Institute of Fisheries and Environment of Inland Sea, Fisheries Research Agency, 2-17-5, Maruishi, Hatsukaichi, Hiroshima 739-0452, Japan
| | - Kazuhiko Mochida
- National Research Institute of Fisheries and Environment of Inland Sea, Fisheries Research Agency, 2-17-5, Maruishi, Hatsukaichi, Hiroshima 739-0452, Japan
| | - Nobuyuki Ohkubo
- National Research Institute of Fisheries and Environment of Inland Sea, Fisheries Research Agency, 2-17-5, Maruishi, Hatsukaichi, Hiroshima 739-0452, Japan
| | - Takeshi Miura
- South Ehime Fisheries Research Center, Ehime University, 1289-1, Funakoshi, Ainan, Ehime 798-4292, Japan
| | - Kazunori Fujii
- National Research Institute of Fisheries and Environment of Inland Sea, Fisheries Research Agency, 2-17-5, Maruishi, Hatsukaichi, Hiroshima 739-0452, Japan
| |
Collapse
|
3
|
Anezaki K, Nagahora S. Characterization of polychlorinated biphenyls, pentachlorobenzene, hexachlorobenzene, polychlorinated dibenzo-p-dioxins, and dibenzofurans in surface sediments of Muroran Port, Japan. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2014; 21:9169-9181. [PMID: 24691935 DOI: 10.1007/s11356-014-2824-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/12/2014] [Accepted: 03/21/2014] [Indexed: 06/03/2023]
Abstract
We determined the distribution of polychlorinated biphenyls (PCBs), pentachlorobenzene (PeCBz), hexachlorobenzene (HxCBz), and polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) in surface sediments at 21 sites inside and outside Muroran Port, Japan. The concentration ranges and geometric means of PCBs (Σ209PCB), PeCBz, HxCBz, and PCDD/Fs and toxicity equivalence quantity (total TEQ) of dioxins inside Muroran Port were 1,100-65,000 (mean, 17,000) pg/g dw, 37-220 (100) pg/g dw, 31-810 (84) pg/g dw, 69-410 (170) pg/g dw, and 0.51-6.2 (2.3) pg TEQ/g dw, respectively. Their corresponding inventories inside Muroran Port were estimated to be 76, 0.31, 0.32, 0.55, and 7.8 g TEQ, respectively. The amounts of these pollutants were higher inside the port than outside the port and especially large in the inner part of the port. Most PCBs were homologues and congeners of penta- to hepta-chlorinated compounds, and the PCBs around Muroran Port were derived from technical PCBs, especially KC500 and KC600. As for PCDD/Fs, the influence of pentachlorophenol was significant, although pollution due to chloronitrofen and combustion was detected. The congeners of PCDD/Fs predominantly contributed to total TEQ. The concentration distributions of PeCBz, HxCBz, and PCDD/Fs and total TEQ were highly correlated with one another. This indicates that they are derived from the same combustion process.
Collapse
Affiliation(s)
- Katsunori Anezaki
- Hokkaido Research Organization, Environmental and Geological Research Department, Institute of Environmental Sciences, N19W12, Kita, Sapporo, Hokkaido, 060-0819, Japan,
| | | |
Collapse
|
4
|
Karademir A, Ergül HA, Telli B, Kılavuz SA, Terzi M. Evaluation of PCDD/F pollution in surface sediments of Izmit Bay. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2013; 20:6611-6619. [PMID: 23613207 DOI: 10.1007/s11356-013-1713-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/25/2012] [Accepted: 04/02/2013] [Indexed: 06/02/2023]
Abstract
This study evaluates PCDD/F pollution in the surface sediments of Izmit Bay (Turkey) and assesses the possible sources of PCDD/F inputs to the bay. The results showed that concentrations of toxic PCDD/F congeners in the sediments varied between 0.45 and 255 ng WHO2005-TEQ/kg dry weight. Pollution mapping shows that PCDD/F levels in the central section of Izmit Bay are much higher than those in the eastern and the western sections. Sediments collected from the northern part of the central section showed very high PCDD/F concentrations. The samples reveal three different congener profiles dominated by OCDF, 1,2,3,4,6,7,8-HpCDF, and OCDD respectively. The dominance of OCDF in the sediment samples taken from the central section was attributed to the former production of vinyl chloride monomer in the area, while that of 1,2,3,4,6,7,8-HpCDF was attributed to the (previously unknown) use of a chlorophenol-based fungicide in the region. The OCDD dominated group was explained by the use of pentachlorophenol. The results indicate that historic industrial discharges are the main contributor to the PCDD/F pollution in the sediments.
Collapse
Affiliation(s)
- Aykan Karademir
- Department of Environmental Engineering, Kocaeli University, 41380, Kocaeli, Turkey.
| | | | | | | | | |
Collapse
|