Almomani MA, Fares MM, Almesidieen EM. Toward long-live ceramic on ceramic hip joints: In vitro investigation of squeaking of coated hip joint with layer-by-layer reinforced PVA coatings. E-POLYMERS 2022. [DOI: 10.1515/epoly-2022-0048] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Abstract
This study attempts to find a promising solution for the squeaking of ceramic on ceramic (COC) bearing surfaces by introducing reinforced poly(vinylalcohol) (PVA) layer-by-layer coatings on the bearing surface of Stryker Trident femoral head. A customized hip simulator was established to provide a realistic simulation of the normal gait (flexion–extension) of the hip joint, and to examine squeaking for coated and uncoated femoral heads. Different characterization techniques were employed to study the coatings’ structure. The PVA macromolecules were successfully cross-linked via epichlorohydrin agent, and chemically bonded onto the surface, forming a superior reinforced PVA coating on the femoral head’s surface. These coatings play a dominant role in increasing the pre-squeaking age of the hip joint due to reduction in hard-on-hard contact and femoral head liner clearance with their good viscoelastic properties. Which cause, damping friction-induced vibrations. This improvement resembles novel-type, long-life, and stable hip joint biomaterials with distinguished and promising pre-squeaking age.
Collapse
Affiliation(s)
- Mohammed A. Almomani
- Department of Industrial Engineering, Faculty of Engineering, Jordan University of Science and Technology , P.O. Box 3030 , Irbid 22110 , Jordan
| | - Mohammad M. Fares
- Department of Chemical Sciences, Faculty of Art and Science, Jordan University of Science and Technology , P.O. Box 3030 , Irbid 22110 , Jordan
| | - Elham M. Almesidieen
- Department of Industrial Engineering, Faculty of Engineering, Jordan University of Science and Technology , P.O. Box 3030 , Irbid 22110 , Jordan
| |
Collapse
|
2
|
Weiss C, Hothan A, Huber G, Morlock MM, Hoffmann NP. Friction-induced whirl vibration: Root cause of squeaking in total hip arthroplasty. J Biomech 2012; 45:297-303. [DOI: 10.1016/j.jbiomech.2011.10.025] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2011] [Revised: 10/17/2011] [Accepted: 10/22/2011] [Indexed: 12/12/2022]
|
3
|
Weiss C, Gdaniec P, Hoffmann NP, Hothan A, Huber G, Morlock MM. Squeak in hip endoprosthesis systems: An experimental study and a numerical technique to analyze design variants. Med Eng Phys 2010; 32:604-9. [DOI: 10.1016/j.medengphy.2010.02.006] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2009] [Revised: 12/23/2009] [Accepted: 02/11/2010] [Indexed: 10/19/2022]
|