1
|
Kloosterman R, Wright GWJ, Salvo-Halloran EM, Ferko NC, Mennone JZ, Clymer JW, Ricketts CD, Tommaselli GA. An umbrella review of the surgical performance of Harmonic ultrasonic devices and impact on patient outcomes. BMC Surg 2023; 23:180. [PMID: 37386399 PMCID: PMC10308659 DOI: 10.1186/s12893-023-02057-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2023] [Accepted: 05/25/2023] [Indexed: 07/01/2023] Open
Abstract
BACKGROUND For thirty years, the Harmonic scalpel has been used for precise dissection, sealing and transection. There are numerous meta-analyses on individual surgical procedures with Harmonic, but no overarching review covering all the areas. This umbrella review seeks to summarize the clinical results from the use of Harmonic across surgical fields and broadly quantify its effects on patient outcomes. METHODS MEDLINE, EMBASE, and Cochrane Databases were searched for meta-analyses (MAs) of randomized controlled trials (RCTs) comparing Harmonic devices to conventional techniques or advanced bipolar (ABP) devices. For each procedure type, the most comprehensive MAs were evaluated. RCTs not already analysed in a MA were also included. Operating time, length of stay, intraoperative blood loss, drainage volume, pain, and overall complications were evaluated, and the methodological quality and certainty of evidence were assessed. RESULTS Twenty-four systematic literature reviews were identified on colectomy, hemorrhoidectomy, gastrectomy, mastectomy, flap harvesting, cholecystectomy, thyroidectomy, tonsillectomy, and neck dissection. There were also 83 RCTs included. In every MA evaluated, Harmonic devices were associated with either statistically significant or numerical improvements in every outcome compared with conventional techniques; most MAs reported a reduction in operating time of ≥ 25 min. Harmonic versus ABP device MAs in colectomy and thyroidectomy showed no significant differences in outcomes. CONCLUSION Across surgical procedures, Harmonic devices demonstrated improved patient outcomes for operating time, length of stay, intraoperative bleeding, drainage volume, pain, and overall complications compared to conventional techniques. Additional studies are required to assess differences between Harmonic and ABP devices.
Collapse
Affiliation(s)
| | | | | | - Nicole C. Ferko
- EVERSANA, 113-3228 South Service Rd., Burlington, ON L7N 3H8 Canada
| | | | | | | | | |
Collapse
|
2
|
Piyade HB, Başoğlu M, Gürsoy E. The effect of different therapeutic treatments on the frequency of postoperative hypocalcemia in patients with thyroidectomy. Turk J Surg 2023; 39:70-75. [PMID: 37275930 PMCID: PMC10234705 DOI: 10.47717/turkjsurg.2023.5886] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2022] [Accepted: 01/16/2023] [Indexed: 06/07/2023]
Abstract
Objectives Thyroid gland surgery and its surgical complications are situations that a surgeon frequently encounters in his daily practice. In our study, it was aimed to examine the effect of different treatment methods given to patients who underwent thyroidectomy on hypocalcemia. Material and Methods Three hundred and seventy-one patients who underwent thyroidectomy at Ondokuz Mayıs University Medical Faculty General Surgery clinic between December 2016 and January 2021 were retrospectively included in the study. Parameters such as surgery indications, fine needle aspiration biopsy results, preoperative serum calcium values, type of surgery, serum calcium values at postoperative 1st day and 1st month, postoperative hospital stay, drugs prescribed at discharge, histopathological diagnosis of the patient, and whether there was incidental parathyroidectomy or not were included. Results Mean age of 371 patients who underwent thyroidectomy was 49 (19-82) years. Total thyroidectomy was the most common type of thyroidectomy with 61% (n= 225) of the patients. There was a significant decrease in pre-op and post-op calcium values in all three types of surgery performed on the patients, and there was no significant difference between the different types of surgery. Post-operative day one and month one serum calcium values were significantly increased in all groups (p= .000). The increase in post-op serum calcium level was most common in the group using calcium carbonate + cholecalciferol + calcitriol. Conclusion The use of post-op calcitriol in patients undergoing thyroidectomy seems to be quite effective in preventing the development of hypocalcemia.
Collapse
Affiliation(s)
| | - Mahmut Başoğlu
- Department of General Surgery, Ondokuz Mayıs University Faculty of Medicine, Samsun, Türkiye
| | - Ersan Gürsoy
- Department of Family Medicine, Binali Yıldırım University Faculty of Medicine, Erzincan, Türkiye
| |
Collapse
|
3
|
Electrocautery, Harmonic, and Thunderbeat Instruments in Parotid Surgery: A Retrospective Comparative Study. J Clin Med 2022; 11:jcm11247414. [PMID: 36556028 PMCID: PMC9788463 DOI: 10.3390/jcm11247414] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2022] [Revised: 12/13/2022] [Accepted: 12/13/2022] [Indexed: 12/23/2022] Open
Abstract
The aim of this retrospective study has been to compare the surgical outcomes of patients undergoing superficial parotidectomy with three different instruments: bipolar electrocautery, ultrasound, and mixed energy instruments. The clinical records of 102 patients who had undergone superficial parotidectomy for benign tumors between January 2016 and April 2022 were considered. Based on the tool used during the surgery, the patients were divided into three study groups: classic electrocautery hemostasis group (CH group), ultrasonic instrument group (HA group), and combined energy instrument group (TB group). The duration of surgery, the total post-operative drainage volume, and the intra-operative blood loss were significantly higher in the CH group compared to the HA and the TB group, while the differences were not significant between the latter two groups. Facial nerve weakness was detected in 45.9% of the CH group, 12.5% of the HA group, and 21.2% of the TB group. The rate of facial nerve dysfunction in the CH group was significantly higher than in the HA group (0.011). In the patients who experienced post-operative facial nerve dysfunction, the recovery time was significantly shorter in the HA group compared to the CH and the TB group. The HA and TB groups have demonstrated comparable and significantly better surgical outcomes than bipolar electrocautery. Ultrasound instruments have been shown to cause, in comparison with the other techniques, a lower rate of temporary facial nerve dysfunction and, if this is present, lead to a faster spontaneous recovery time.
Collapse
|
4
|
Shibao K, Honda S, Adachi Y, Kohi S, Kudou Y, Matayoshi N, Sato N, Hirata K. An advanced bipolar device helps reduce the rate of postoperative pancreatic fistula in laparoscopic gastrectomy for gastric cancer patients: a propensity score-matched analysis. Langenbecks Arch Surg 2022; 407:3479-3486. [PMID: 36181517 PMCID: PMC9722839 DOI: 10.1007/s00423-022-02692-5] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2022] [Accepted: 09/15/2022] [Indexed: 10/07/2022]
Abstract
BACKGROUND Advanced bipolar devices (ABD; e.g., LigaSure™) have a lower blade temperature than ultrasonically activated devices (USAD; e.g., Harmonic® and Sonicision™) during activation, potentially enabling accurate lymph node dissection with less risk of postoperative pancreatic fistula (POPF) due to pancreatic thermal injury in laparoscopic gastrectomy. Therefore, we compared the efficacy and safety of ABD and USAD in laparoscopic gastrectomy for gastric cancer patients. METHODS A retrospective cohort study was conducted on patients who underwent laparoscopic distal gastrectomy (LDG) between August 2008 and September 2020. A total of 371 patients were enrolled, and short-term surgical outcomes, including the incidence of ISGPF grades B and C POPF, were compared between ABD and USAD. The risk factors for POPF in LDG were investigated by univariate and multivariate analyses. RESULTS A propensity score-matching algorithm was used to select 120 patients for each group. The POPF rate was significantly lower (0.8 vs. 9.2%, p < 0.001), the morbidity rate was lower (13.3 vs. 28.3%, p < 0.001), the length of postoperative hospitalization was shorter (14 vs. 19 days, p < 0.001), and the lymph node retrieval rate was higher (34 vs. 26, p < 0.001) with an ABD than with a USAD. There were no mortalities in either group. A multivariate analysis showed that a USAD was the only independent risk factor with a considerably high odds ratio for the occurrence of POPF (USAD/ABD, odds ratio 8.38, p = 0.0466). CONCLUSION An ABD may improve the safety of laparoscopic gastrectomy for gastric cancer patients.
Collapse
Affiliation(s)
- Kazunori Shibao
- Department of Surgery I, School of Medicine, University of Occupational and Environmental Health Japan, 1-1 Iseigaoka, Yahatanishi ward, Kitakyushu, Fukuoka, 807-8555, Japan.
| | - Shinsaku Honda
- Department of Surgery I, School of Medicine, University of Occupational and Environmental Health Japan, 1-1 Iseigaoka, Yahatanishi ward, Kitakyushu, Fukuoka, 807-8555, Japan
| | - Yasuhiro Adachi
- Department of Surgery I, School of Medicine, University of Occupational and Environmental Health Japan, 1-1 Iseigaoka, Yahatanishi ward, Kitakyushu, Fukuoka, 807-8555, Japan
| | - Shiro Kohi
- Department of Surgery I, School of Medicine, University of Occupational and Environmental Health Japan, 1-1 Iseigaoka, Yahatanishi ward, Kitakyushu, Fukuoka, 807-8555, Japan
| | - Yuzan Kudou
- Department of Surgery I, School of Medicine, University of Occupational and Environmental Health Japan, 1-1 Iseigaoka, Yahatanishi ward, Kitakyushu, Fukuoka, 807-8555, Japan
| | - Nobutaka Matayoshi
- Department of Surgery I, School of Medicine, University of Occupational and Environmental Health Japan, 1-1 Iseigaoka, Yahatanishi ward, Kitakyushu, Fukuoka, 807-8555, Japan
| | - Nagahiro Sato
- Department of Surgery I, School of Medicine, University of Occupational and Environmental Health Japan, 1-1 Iseigaoka, Yahatanishi ward, Kitakyushu, Fukuoka, 807-8555, Japan
| | - Keiji Hirata
- Department of Surgery I, School of Medicine, University of Occupational and Environmental Health Japan, 1-1 Iseigaoka, Yahatanishi ward, Kitakyushu, Fukuoka, 807-8555, Japan
| |
Collapse
|
5
|
De Napoli L, Matrone A, Ambrosini CE, Becucci C, Pieroni E, Vagelli F, Taddei G, Gjeloshi B, Torregrossa L, Elisei R, Spinelli C, Materazzi G. Impact of energy-based devices in pediatric thyroid surgery. J Pediatr Surg 2022; 57:740-745. [PMID: 35469657 DOI: 10.1016/j.jpedsurg.2022.03.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/02/2021] [Revised: 02/20/2022] [Accepted: 03/05/2022] [Indexed: 10/31/2022]
Abstract
BACKGROUND Energy-based devices are surgical devices increasingly utilized for thyroid surgery, owing to a reduction of operative time and surgical related complications. The aim of the study is to evaluate whether the use of energy-based devices could improve the complication rate in pediatric thyroid surgery. METHODS This is a retrospective observational study. We identified 177 consecutive pediatric patients (Group A) with thyroid diseases, surgically treated by energy-based devices and 237 patients (Group B) treated by conventional clamp and tie technique and matched for sex, age and indication for surgery. Transient and permanent complications rate, operative time and length of hospital stay were compared between the two groups. RESULTS Patients of Group A experienced a lower complication rate compared to Group B. Particularly, transient (11.3 vs. 19% p < 0.05) and permanent post operative hypoparathyroidism (1.7 vs. 5.5%, p < 0.05) were lower in Group A. Moreover, operative time was also shorter in Group A compared to Group B and this difference was statistically significant in patients who performed total thyroidectomy alone and total thyroidectomy associated with central compartment neck dissection (p < 0.05). Length of hospital stay was lower in Group A than in Group B, but this difference was statistically significant only for microfollicular lesion (p < 0.05). CONCLUSION The use of energy-based devices has a key role in reducing surgical related complications, particularly transient and permanent hypoparathyroidism, operative time and length of hospital stay in pediatric patients treated with thyroid surgery. LEVEL OF EVIDENCE Level III. TYPE OF STUDY Retrospective comparative study.
Collapse
Affiliation(s)
- Luigi De Napoli
- Department of Surgical, Medical and Molecular Pathology and Critical Area, University of Pisa, Pisa, Italy.
| | - Antonio Matrone
- Department of Clinical and Experimental Medicine, Unit of Endocrinology, University of Pisa, Pisa, Italy
| | - Carlo Enrico Ambrosini
- Department of Surgical, Medical and Molecular Pathology and Critical Area, University of Pisa, Pisa, Italy
| | - Chiara Becucci
- Department of Surgical, Medical and Molecular Pathology and Critical Area, University of Pisa, Pisa, Italy
| | - Erica Pieroni
- Department of Surgical, Medical and Molecular Pathology and Critical Area, University of Pisa, Pisa, Italy
| | - Filippo Vagelli
- Department of Surgical, Medical and Molecular Pathology and Critical Area, University of Pisa, Pisa, Italy
| | - Giacomo Taddei
- Department of Surgical, Medical and Molecular Pathology and Critical Area, University of Pisa, Pisa, Italy
| | - Benard Gjeloshi
- Department of Surgical, Medical and Molecular Pathology and Critical Area, University of Pisa, Pisa, Italy
| | - Liborio Torregrossa
- Department of Surgical, Medical and Molecular Pathology and Critical Area, University of Pisa, Pisa, Italy
| | - Rossella Elisei
- Department of Clinical and Experimental Medicine, Unit of Endocrinology, University of Pisa, Pisa, Italy
| | - Claudio Spinelli
- Department of Surgical, Medical and Molecular Pathology and Critical Area, University of Pisa, Pisa, Italy
| | - Gabriele Materazzi
- Department of Surgical, Medical and Molecular Pathology and Critical Area, University of Pisa, Pisa, Italy
| |
Collapse
|
6
|
Clinical Usefulness of the Valsalva Manoeuvre to Improve Hemostasis during Thyroidectomy. J Clin Med 2022; 11:jcm11195791. [PMID: 36233658 PMCID: PMC9571820 DOI: 10.3390/jcm11195791] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2022] [Revised: 09/23/2022] [Accepted: 09/27/2022] [Indexed: 11/16/2022] Open
Abstract
Bleeding after total thyroidectomy remains a rare event that affects early postoperative morbidity, occurring in 0.3% to 4.2% of cases. Intraoperative bleeding is an unpleasant complication, and it is often easily manageable, although postoperative bleeding may represent a life-threatening condition for the patient. The purpose of our study was to clarify the role of the Valsalva manoeuvre to reduce postoperative bleeding. Between January 2019 to February 2022, 250 consecutive patients were listed for thyroid surgery at our surgical department. The study cohort consisted of 178 patients, divided into two groups based on the execution of the Valsalva manoeuvre. There was no difference in the duration of surgery between groups. Group B had fewer reinterventions for bleeding. Group A had a significantly greater volume of drainage output than Group B. Cervical haematoma can compromise a patient’s life, so bleeding control is crucial. Our results show that using a simple and safe Valsalva manoeuvre can improve the postoperative course with a significant reduction in drainage output, but does not prevent the risk of reoperation for hemorrhage.
Collapse
|
7
|
Zheng W, Zhu S, Zhang Y, Wang Z, Liao S, Sun S. Novel application of microdissection tungsten needle in total thyroidectomy with central neck dissection for papillary thyroid carcinoma. Front Surg 2022; 9:896275. [PMID: 36090347 PMCID: PMC9458924 DOI: 10.3389/fsurg.2022.896275] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2022] [Accepted: 08/04/2022] [Indexed: 11/16/2022] Open
Abstract
Background Energy-based devices (EBD) have been popularized in thyroidectomy worldwide. Microdissection tungsten needle (MDTN) is characterized by the ultra-sharp tip providing safe and meticulous dissection with effective hemostasis. However, little study has applied MDTN in thyroidectomy. Methods This retrospective study compared clinical data of the patients who underwent total thyroidectomy (TT) with central neck dissection (CND) using MDTN, harmonic scalpel (HS), and conventional electrocautery (CE). We assessed outcomes related to surgical efficacy and safety. The injury degree of tissue was assessed by biochemical indicators and early-stage inflammatory factors in the drainage fluid. Histological sections of the thyroid specimens were evaluated to compare levels of thermal damage by the three EBD. Results There was a significant decrease in the intraoperative blood loss, operation time and 24-hour drainage volume in the MDTN group compared to the CE group. The total drainage volume, duration of drainage, and average length of stay of the MDTN group were less compared to the CE group though they did not reach statistical significance. No disparity was observed between the MDTN group and HS group in these variables. Total costs were not significantly different among these groups. The incidence of recurrent laryngeal nerve (RLN) injury was the lowest using MDTN compared to the CE (P = 0.034) and HS (not significant). No statistical differences were observed among these groups regarding postoperative wound pain and infection, hypoparathyroidism, and postoperative hemorrhage. Analysis of biochemical indicators showed a lower level of hemoglobin in the MDTN and HS group than the CE group (P = 0.046 and 0.038, respectively) and less triglyceride in the HS group than the MDTN and CE group (P = 0.002 and 0.029, respectively) but no significant difference in cholesterol level in these groups. Early-stage inflammatory factors including TNF-α and IL-6 showed significantly higher concentration in the CE group than the MDTN and HS group. Histological sections of thyroid specimens revealed that MDTN caused the lowest degree of thermal damage followed by HS then CE.
Conclusion MDTN exhibited comparable surgical efficacy and safety outcomes as HS in thyroidectomy. Therefore, MDTN is a safe and viable alternative for hemostasis in thyroidectomy.
Collapse
|
8
|
Al Naem M, Litzke LF, Mourad AAG. Thyroidectomy facilitated with Harmonic Caliper and intraoperative neural monitoring in three horses. EQUINE VET EDUC 2022. [DOI: 10.1111/eve.13635] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Affiliation(s)
- M. Al Naem
- Equine Clinic (Surgery, Orthopaedics) Faculty of Veterinary Medicine Justus‐Liebig‐University Giessen Germany
| | - L. F. Litzke
- Equine Clinic (Surgery, Orthopaedics) Faculty of Veterinary Medicine Justus‐Liebig‐University Giessen Germany
| | - A. A. G. Mourad
- Department of Surgery, Anaesthesiology and Radiology Faculty of Veterinary Medicine University of Sadat City Sadat City Egypt
| |
Collapse
|
9
|
Tirone F, Salzano S, Panuello P, Pozzatti L, Rodi D. Is the postoperative discomfort after connective tissue harvesting from the palate influenced by the use of a bipolar coagulator? A randomized controlled trial. Clin Exp Dent Res 2021; 7:1053-1060. [PMID: 33987929 PMCID: PMC8638320 DOI: 10.1002/cre2.441] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2021] [Revised: 04/14/2021] [Accepted: 04/27/2021] [Indexed: 11/20/2022] Open
Abstract
Objectives This study aimed to determine the effect of the use of a bipolar coagulator on postoperative pain and complications when used during connective tissue harvesting from the palate. Material and methods A randomized controlled clinical trial was conducted with 57 sequential patients requiring a connective tissue graft for periodontal or implant surgery. All samples were harvested superficially and de‐epithelized outside the mouth. The patients were randomly allocated to two groups: in one group, the bipolar coagulator was used before suturing to control bleeding, and in the other group, the coagulator was not used. The surgeon was unaware of the randomization until the end of the harvesting phase. Self‐reported maximum pain, number of painkillers used, bleeding events, emergency visits at the clinic were recorded 7 days after surgery. Results Fifty patients were randomized and treated (seven were excluded for different reasons). The mean harvested area was 75.24 mm2 (SD, 33.96), and the mean thickness of the samples was 2.47 mm (SD, 0.75). The mean self‐reported pain value on the visual analog scale was 3.37 (SD, 2.30), and the mean number of pain medications used was 7.1 (SD, 6.60). Seven patients made an emergency visit each, and 17 delayed bleeding events were reported by 15 patients. No statistically significant differences were reported in postoperative pain, postoperative bleeding, and emergency visit to the clinic between the groups that did and did not use the bipolar coagulator. When smoking habits were taken into consideration, the number of pain medications was higher among male smokers and older smokers than among male non‐smokers and younger smokers. This study was not able to find a relationship between harvested sample dimension or thickness and postoperative discomfort. Conclusions The bipolar coagulator can be used during connective tissue harvesting from the palate to control bleeding without influencing postoperative pain.
Collapse
Affiliation(s)
- Federico Tirone
- Clinica Odontoiatrica Salzano Tirone, Private Practice, Cuneo, Italy
| | - Stefano Salzano
- Clinica Odontoiatrica Salzano Tirone, Private Practice, Cuneo, Italy
| | - Paola Panuello
- Clinica Odontoiatrica Salzano Tirone, Private Practice, Cuneo, Italy
| | | | | |
Collapse
|
10
|
Spartalis E, Giannakodimos A, Ziogou A, Giannakodimos I, Paschou SA, Spartalis M, Schizas D, Troupis T. Effect of energy-based devices on post-operative parathyroid function and blood calcium levels after total thyroidectomy. Expert Rev Med Devices 2021; 18:291-298. [PMID: 33666537 DOI: 10.1080/17434440.2021.1899805] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/07/2022]
Abstract
Introduction: Energy-based devices are widely used in thyroid surgery in order to achieve optimal hemostasis, while their role in the incidence of hypocalcemia and hypoparathyroidism comprises a topic evaluated in numerous studies.Areas covered: The aim of this systematic review is to investigate the potential benefit of Ultrasonic Shears and Electrothermal Bipolar (Radiofrequency) System in thyroid surgery regarding the incidence of post-operative hypocalcemia and hypoparathyroidism. A systematic review of the literature in PubMed/Medline and Scopus databases was conducted. Forty-nine studies met the inclusion criteria and were analyzed. A statistically decreased rate of transient hypocalcemia and hypoparathyroidism was reported in 15 studies and 4 studies, respectively, when using energy-based devices. However, 18 and 13 surveys examined transient hypocalcemia and hypoparathyroidism, respectively, and demonstrated no statistical difference between energy-based devices and conventional hemostasis. No difference was observed between the groups concerning permanent hypocalcemia. Out of 13 studies, only 2 showed a significant reduction in the occurrence of permanent hypoparathyroidism in the energy-based device group.Expert opinion: Energy-based devices reduced the rate of transient hypocalcemia and hypoparathyroidism after thyroid surgeries in 42.8% and 23.5% of the included studies, respectively. Further studies are needed to evaluate their impact on permanent post-operative hypocalcemia and hypoparathyroidism.
Collapse
Affiliation(s)
- Eleftherios Spartalis
- 2nd Department of Propaedeutic Surgery, National and Kapodistrian University of Athens, Medical School, Athens, Greece.,Laboratory of Experimental Surgery and Surgical Research "N.S Christeas," National and Kapodistrian University of Athens, Medical School, Athens, Greece.,Department of Anatomy, Medical School, National and Kapodistrian University of Athens, Medical School, Athens, Greece
| | - Alexios Giannakodimos
- 2 Department of Propaedeutic Surgery, National and Kapodistrian University of Athens, Medical School, Athens, Greece
| | - Afroditi Ziogou
- Third Department of Surgery, National and Kapodistrian University of Athens, Attikon University Hospital, Athens, Greece
| | - Ilias Giannakodimos
- 1st Department of Surgery, National and Kapodistrian University of Athens, Athens, Greece
| | - Stavroula A Paschou
- Division of Endocrinology, Diabetes and Metabolism, Department of Clinical Therapeutics, Alexandra Hospital, School of Medicine, National and Kapodistrian University of Athens, Athens, Greece
| | - Michael Spartalis
- Laboratory of Experimental Surgery and Surgical Research "N.S Christeas," National and Kapodistrian University of Athens, Medical School, Athens, Greece
| | - Dimitrios Schizas
- 1st Department of Surgery, National and Kapodistrian University of Athens, Athens, Greece
| | - Theodore Troupis
- Department of Anatomy, Medical School, National and Kapodistrian University of Athens, Medical School, Athens, Greece
| |
Collapse
|
11
|
Kim WW, Cho J, Jeon YS, Kim I, Jeong YJ, Choi J, Lee MH, Lee J, Kang JG, Tufano RP, Kang SH. Prospective, Randomized, Comparative, Multicenter Study of the Hybrid Ultrasonic Advanced Bipolar Device and the Ultrasonic Coagulating Shears in Open Thyroidectomy. Surg Innov 2020; 28:41-47. [PMID: 32757879 DOI: 10.1177/1553350620949000] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Background. The hybrid ultrasonic advanced bipolar device (HUB) that integrates ultrasonic energy and advanced bipolar energy was recently developed and applied to thyroid surgery. The purpose of this study was to compare the efficacy and safety of HUB and ultrasonic coagulating shears for open thyroidectomy. Methods. A total of 200 patients were enrolled from April to September 2017 in this prospective, randomized, multicenter study. Patients were randomly assigned to an ultrasonic group (n = 101) or a hybrid group (n = 99). Results. Operation times were similar in the 2 study groups, that is, 54.2 ± 25.2 minutes in the ultrasonic group and 50.2 ± 21.6 minutes in the hybrid group. Postoperative surgical results and morbidities were no different in the 2 groups. However, the total amount of bleeding was significantly less in the hybrid group (13.0 ± 17.7 mg vs 8.6 ± 11.5 mg; P = .042). Conclusions. Our study showed that there was no significant difference between the 2 groups in postoperative surgical results and morbidity. The total bleeding amount was significantly less in the hybrid group. The study shows that HUB is comparable to the ultrasonic coagulating shears in terms of efficacy and safety during thyroid surgery.
Collapse
Affiliation(s)
- Wan Wook Kim
- Department of Surgery, School of Medicine, 65672Kyungpook National University, Daegu, Republic of Korea
| | - Jihyoung Cho
- Department of Surgery, School of Medicine, 37976Keimyung University, Daegu, Republic of Korea
| | - Young San Jeon
- Department of Surgery, Goo Hospital, Daegu, Republic of Korea
| | - Insoo Kim
- Department of Surgery, Daegu Fatima Hospital, Daegu, Republic of Korea
| | - Young Ju Jeong
- Department of Surgery, School of Medicine, Catholic University of Daegu, Daegu, Republic of Korea
| | - Jungeun Choi
- Department of Surgery, College of Medicine, Yeungnam University, Daegu, Republic of Korea
| | - Moo Hyun Lee
- Department of Surgery, School of Medicine, 37976Keimyung University, Daegu, Republic of Korea
| | - Jehyung Lee
- Department of Surgery, Goo Hospital, Daegu, Republic of Korea
| | - Jin Gu Kang
- Department of Surgery, College of Medicine, Yeungnam University, Daegu, Republic of Korea
| | - Ralph P Tufano
- Department of Otolaryngology-Head and Neck Surgery, Johns Hopkins University School of Medicine, Baltimore, MD, USA
| | - Su Hwan Kang
- Department of Surgery, College of Medicine, Yeungnam University, Daegu, Republic of Korea
| |
Collapse
|
12
|
Huang TY, Lin YC, Tseng HY, Dionigi G, Kim HY, Chai YJ, Lu IC, Chang PY, Chiang FY, Wu CW. Safety parameters of ferromagnetic device during thyroid surgery: Porcine model using continuous neuromonitoring. Head Neck 2020; 42:2931-2940. [PMID: 32567742 DOI: 10.1002/hed.26334] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2020] [Revised: 04/28/2020] [Accepted: 05/30/2020] [Indexed: 12/17/2022] Open
Abstract
BACKGROUND The ferromagnetic (FM) device is a new surgical energy modality. This study investigated dynamic recurrent laryngeal nerve (RLN) electromyographic (EMG) data to define safety parameters for using FM devices in thyroidectomy. METHODS Real-time EMG tracings obtained under continuous neuromonitoring were recorded from 24 RLNs (12 piglets). In the activation study, FM devices were activated at varying distances from the RLN. In the cooling study, FM devices were cooled for varying time intervals, or muscle touch maneuver was performed, before contact with the RLN. RESULTS During the FMwand/FMsealer activation, no adverse EMG events occurred at distances of 2 mm or longer. The cooling study revealed no adverse EMG events after 1-second (FMwand) or 3-second (FMsealer) intervals or after muscle touch maneuver. CONCLUSIONS An FM device should be activated at a distance of 2 mm from the RLN and should be adequately cooled before further contact with the RLN. Surgeons can avoid RLN injury by observing standard procedures for using FM devices.
Collapse
Affiliation(s)
- Tzu-Yen Huang
- Department of Otolaryngology-Head and Neck Surgery, Kaohsiung Medical University Hospital, Kaohsiung Medical University, Kaohsiung, Taiwan.,Department of Biological Science and Technology, National Chiao Tung University, Taiwan
| | - Yi-Chu Lin
- Department of Otolaryngology-Head and Neck Surgery, Kaohsiung Medical University Hospital, Kaohsiung Medical University, Kaohsiung, Taiwan
| | - Hsin-Yi Tseng
- Department of Otolaryngology-Head and Neck Surgery, Kaohsiung Medical University Hospital, Kaohsiung Medical University, Kaohsiung, Taiwan
| | - Gianlorenzo Dionigi
- Division for Endocrine and Minimally Invasive Surgery, Department of Human Pathology in Adulthood and Childhood "Gaetano Barresi", University Hospital G. Martino, University of Messina, Messina, Italy
| | - Hoon Yub Kim
- Department of Surgery, KUMC Thyroid Center, Korea University College of Medicine, Seoul, South Korea
| | - Young Jun Chai
- Department of Surgery, Seoul Metropolitan Government-Seoul National University Boramae Medical Center, Seoul, South Korea
| | - I-Cheng Lu
- Department of Anesthesiology, Kaohsiung Municipal Siaogang Hospital, Kaohsiung Medical University Hospital, Faculty of Medicine, College of Medicine, Kaohsiung Medical University, Kaohsiung, Taiwan
| | - Pi-Ying Chang
- Department of Anesthesiology, Kaohsiung Municipal Siaogang Hospital, Kaohsiung Medical University Hospital, Faculty of Medicine, College of Medicine, Kaohsiung Medical University, Kaohsiung, Taiwan
| | - Feng-Yu Chiang
- School of Medicine, College of Medicine, I-Shou University, Kaohsiung, Taiwan.,Department of Otolaryngology, E-Da Hospital, Kaohsiung, Taiwan
| | - Che-Wei Wu
- Department of Otolaryngology-Head and Neck Surgery, Kaohsiung Medical University Hospital, Kaohsiung Medical University, Kaohsiung, Taiwan.,Department of Otorhinolaryngology-Head and Neck Surgery, Kaohsiung Municipal Siaogang Hospital, Faculty of Medicine, College of Medicine, and Cohort Research Center, Kaohsiung Medical University, Shin-Chuan 1st Road, Kaohsiung, Sanmin Dist., 80708, Taiwan
| |
Collapse
|
13
|
Martinez-Monedero R, Danielian A, Angajala V, Dinalo JE, Kezirian EJ. Methodological Quality of Systematic Reviews and Meta-analyses Published in High-Impact Otolaryngology Journals. Otolaryngol Head Neck Surg 2020; 163:892-905. [PMID: 32450783 DOI: 10.1177/0194599820924621] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
OBJECTIVE To assess the methodological quality of intervention-focused systematic reviews (SRs) and meta-analyses (MAs) published in high-impact otolaryngology journals. DATA SOURCES Ovid Medline, Embase, and Cochrane Library. REVIEW METHODS A comprehensive search was performed for SR and MA citations from 2012 to 2017 in the 10 highest impact factor otolaryngology journals. Abstracts were screened to identify published manuscripts in which the authors indicated clearly that they were performing an SR or MA. Applying a modified typology of reviews, 4 reviewers characterized the review type as SR, MA, or another review type. A simplified version of the AMSTAR 2 (A MeaSurement Tool to Assess systematic Reviews 2) tool was used to assess the reporting and methodological quality of the SRs and MAs that were focused on interventions. RESULTS Search and abstract screening generated 499 manuscripts that identified themselves as performing an SR or MA. A substantial number (85/499, 17%) were review types other than SRs or MAs, including 34 (7%) that were literature reviews. In total, 236 SRs and MAs focused on interventions. Over 50% of these SRs and MAs had weaknesses in at least 3 of the 16 items in the AMSTAR 2, and over 40% had weaknesses in at least 2 of the 7 critical domains. Ninety-nine percent of SRs and MAs provided critically low confidence in the results of the reviews. CONCLUSION Intervention-focused SRs and MAs published in high-impact otolaryngology journals have important methodological limitations that diminish confidence in the results of these reviews.
Collapse
Affiliation(s)
- Rodrigo Martinez-Monedero
- USC Caruso Department of Otolaryngology-Head & Neck Surgery, Keck School of Medicine of USC, California, USA
| | - Arman Danielian
- Department of Head and Neck Surgery, David Geffen School of Medicine at UCLA, Los Angeles, California, USA
| | - Varun Angajala
- Keck School of Medicine of USC, Los Angeles, California, USA
| | - Jennifer E Dinalo
- Health Sciences Libraries, Keck School of Medicine of USC, Los Angeles, California, USA
| | - Eric J Kezirian
- USC Caruso Department of Otolaryngology-Head & Neck Surgery, Keck School of Medicine of USC, California, USA
| |
Collapse
|
14
|
Torabi SJ, Avery JM, Salehi PP, Lee Y. Risk factors and effects of hypocalcemia prior to discharge following thyroidectomy. Am J Otolaryngol 2020; 41:102420. [PMID: 32139087 DOI: 10.1016/j.amjoto.2020.102420] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2019] [Accepted: 02/09/2020] [Indexed: 11/30/2022]
Abstract
PURPOSE To find patient and surgical characteristics associated with hypocalcemia prior to discharge (HPTD) in thyroidectomy patients. MATERIALS AND METHODS In a retrospective analysis of the 2016-2017 National Surgical Quality Improvement Program, eligible total thyroidectomy patients were stratified into cohorts based on development of HPTD. We identified demographic and surgical risk factors for the development of hypocalcemia via binary logistic regression and identified the negative sequelae of HPTD utilizing univariate and multivariate methods. RESULTS We identified a total of 6519 patients who underwent total thyroidectomy, of which 450 (6.9%) had HPTD. Predictors associated with an increased incidence of HPTD included female sex (OR: 1.737 [95% CI: 1.319-2.288]; p < .001), increased operative time (OR: 1.003 [1.002-1.004]; p < .001), and central neck dissection (OR: 1.484 [1.190-1.850]; p < .001). However, factors that decreased incidence of HPTD included increased age, obesity (OR: 0.648 [0.501-0.837]; p = .001), and the use of vessel sealant devices (VSD) (OR: 0.650 [0.527-0.803]; p < .001). Multivariate analysis further revealed that HPTD independently led to an increased hospitalization length after surgery (B: 0.708 [0.607-0.809]; p < .001) and an increased 30-day readmission rate (OR: 2.429 [1.594-3.704]; p < .001). CONCLUSION Obesity, increased age, and intra-operative VSD use were significantly associated with decreased rates of HPTD after total thyroidectomy. Female sex, longer operations, and central neck dissections were associated with HPTD. Delineating risk factors and protective factors for HPTD in total thyroidectomy patients is important as patients with HPTD were found to be at a significantly higher risk for longer post-operative stays, increased odds of 30-day readmission, and increased hypocalcemia-related event.
Collapse
Affiliation(s)
- Sina J Torabi
- Department of Surgery, Division of Otolaryngology, Yale School of Medicine, New Haven, CT, United States of America.
| | - Jonathan M Avery
- Department of Surgery, Division of Otolaryngology, Yale School of Medicine, New Haven, CT, United States of America.
| | - Parsa P Salehi
- Department of Surgery, Division of Otolaryngology, Yale School of Medicine, New Haven, CT, United States of America.
| | - Yan Lee
- Department of Surgery, Division of Otolaryngology, Yale School of Medicine, New Haven, CT, United States of America.
| |
Collapse
|
15
|
Siu JM, McCarty JC, Gadkaree S, Caterson EJ, Randolph G, Witterick IJ, Eskander A, Bergmark RW. Association of Vessel-Sealant Devices vs Conventional Hemostasis With Postoperative Neck Hematoma After Thyroid Operations. JAMA Surg 2019; 154:e193146. [PMID: 31532475 DOI: 10.1001/jamasurg.2019.3146] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
Importance Vessel-sealant devices (VSDs) have been popularized for use in thyroid operations; however, the association of their use with postoperative neck hematoma, a rare but potentially fatal complication, has not been well studied. Objective To examine the association of VSDs vs conventional hemostasis (CH) in thyroid operations with the development of neck hematoma. Design, Setting, and Participants This retrospective cohort study evaluated 10 903 patients in the Thyroid Procedure-Targeted Database of the National Surgical Quality Improvement Program from January 1, 2016, to December 31, 2017. One-to-one nearest-neighbor propensity score matching was conducted to adjust for differences in baseline covariates, including demographics, comorbidities, indications for thyroid procedure (goiter, Graves disease, malignant and benign thyroid nodule), and several other thyroid-specific characteristics, between the VSD and CH groups. Main Outcomes and Measures The primary outcome was postoperative hematoma requiring intervention with open evacuation, return to the operating room, tracheostomy, additional observation, or extended length of stay. Secondary outcomes include recurrent laryngeal nerve injury, operative duration, and hospital length of stay. Results One-to-one propensity score matching yielded 6522 patients (mean [SD] age, 52 [15] years; 8544 [78.4%] female) with 3261 in each exposure group such that distribution of observed baseline covariates was not different between groups of the same propensity score. Within the matched cohort, CH was associated with higher odds of neck hematoma compared with VSD (odds ratio, 2.33; 95% CI, 1.55-3.49; P < .001), with 34 (1.0%) hematomas in the VSD group and 78 (2.4%) in the CH group. On the basis of this analysis, the number needed to treat with a VSD to prevent 1 postoperative hematoma was 74. Secondary outcomes included longer length of hospital stay (incidence rate ratio, 1.29; 95% CI, 1.23-1.36; P < .001]) in the CH group compared with the VSD group but no difference in the odds of recurrent laryngeal nerve injury (odds ratio, 0.90; 95% CI, 0.73-1.11; P = .32) or operative duration (incidence rate ratio, 0.99; 95% CI, 0.96-1.01; P = .24). Conclusions and Relevance Use of VSDs during thyroid operations was associated with reduced odds of neck hematoma compared with CH techniques without increasing odds of nerve injury. The results suggest that postoperative neck hematoma rates after thyroid surgery may differ based on the hemostasis technique and that these differences should be considered when developing strategies for quality improvement of postoperative outcomes.
Collapse
Affiliation(s)
- Jennifer M Siu
- Center for Surgery and Public Health, Brigham and Women's Hospital, Boston, Massachusetts.,Department of Otolaryngology-Head & Neck Surgery, University of Toronto, Toronto, Ontario, Canada
| | - Justin C McCarty
- Center for Surgery and Public Health, Brigham and Women's Hospital, Boston, Massachusetts.,Division of Plastic and Reconstructive Surgery, Brigham and Women's Hospital, Boston, Massachusetts
| | - Shekhar Gadkaree
- Department of Otolaryngology, Massachusetts Eye and Ear Infirmary, Boston.,Department of Otolaryngology-Head & Neck Surgery, Harvard Medical School, Boston, Massachusetts
| | - Edward J Caterson
- Division of Plastic and Reconstructive Surgery, Brigham and Women's Hospital, Boston, Massachusetts
| | - Gregory Randolph
- Department of Otolaryngology, Massachusetts Eye and Ear Infirmary, Boston.,Department of Otolaryngology-Head & Neck Surgery, Harvard Medical School, Boston, Massachusetts
| | - Ian J Witterick
- Department of Otolaryngology-Head & Neck Surgery, University of Toronto, Toronto, Ontario, Canada
| | - Antoine Eskander
- Institute for Health Policy Management and Evaluation, University of Toronto, Toronto, Ontario, Canada.,Department of Otolaryngology-Head & Neck Surgery, Surgical Oncology, University of Toronto, Sunnybrook Health Sciences Centre and Michael Garron Hospital, Toronto, Ontario, Canada
| | - Regan W Bergmark
- Center for Surgery and Public Health, Brigham and Women's Hospital, Boston, Massachusetts.,Department of Otolaryngology-Head & Neck Surgery, Harvard Medical School, Boston, Massachusetts.,Division of Otolaryngology-Head and Neck Surgery, Brigham and Women's Hospital and Dana Farber Cancer Institute, Boston, Massachusetts
| |
Collapse
|
16
|
Fraga TS, Köhler HF, Chulam TC, Kowalski LP. Impact of scalpel type on operative time and acute complications in thyroidectomies. Braz J Otorhinolaryngol 2019; 87:205-209. [PMID: 31668788 PMCID: PMC9422565 DOI: 10.1016/j.bjorl.2019.08.004] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2019] [Revised: 08/01/2019] [Accepted: 08/13/2019] [Indexed: 11/26/2022] Open
Abstract
INTRODUCTION Thyroidectomy is the most common surgery in the cervical region. Currently, several techniques are available for intraoperative hemostasis. OBJECTIVE To compare the performance of three techniques (monopolar and bipolar electrical and ultrasonic) on operative time and postoperative complications. METHODS Patients submitted to total thyroidectomy without prior treatment were included in this prospective series study, using a scientific design. RESULTS A total of 834 patients were included; 661 women (79.3%) and 173 men (20.7%). The diagnosis was malignant neoplasia in 528 patients (63.3%) and benign disease in 306 patients (36.7%). The monopolar electric scalpel was used in 280 patients (33.6%), bipolar scalpel in 210 patients (25.2%) and ultrasonic scalpel in 344 patients (41.3%). The operative time was significantly shorter with the ultrasonic or bipolar scalpel when compared to the electric scalpel. In a linear regression model, gender, malignancy diagnosis and power energy type were significant for the procedure duration. Patients who underwent surgery with an ultrasound or bipolar scalpel had a significantly lower incidence of hypoparathyroidism. CONCLUSION The use of ultrasonic or bipolar scalpel significantly reduces operative time and the incidence of transient hypoparathyroidism.
Collapse
Affiliation(s)
- Tamires Santos Fraga
- A.C. Camargo Câncer Center, Departamento de Cirurgia de Cabeça e Pescoço e Otorrinolaringologia, São Paulo, SP, Brazil
| | - Hugo Fontan Köhler
- A.C. Camargo Câncer Center, Departamento de Cirurgia de Cabeça e Pescoço e Otorrinolaringologia, São Paulo, SP, Brazil.
| | - Thiago Celestino Chulam
- A.C. Camargo Câncer Center, Departamento de Cirurgia de Cabeça e Pescoço e Otorrinolaringologia, São Paulo, SP, Brazil
| | - Luiz Paulo Kowalski
- A.C. Camargo Câncer Center, Departamento de Cirurgia de Cabeça e Pescoço e Otorrinolaringologia, São Paulo, SP, Brazil
| |
Collapse
|
17
|
Li D, Kou Y, Huang S, Wang Z, Ning C, Zhao T. The harmonic scalpel versus electrocautery for parotidectomy: A meta - analysis. J Craniomaxillofac Surg 2019; 47:915-921. [PMID: 30954384 DOI: 10.1016/j.jcms.2019.01.008] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2018] [Revised: 11/26/2018] [Accepted: 01/04/2019] [Indexed: 10/27/2022] Open
Abstract
OBJECTIVE Parotidectomy is the most classic and unequivocal intervention for parotid neoplasm. The operative outcomes and postoperative complications of parotidectomy between harmonic scalpel and electrocautery gained more prominence in physician. In spite of much research work within the past years, there was an obvious lack of randomized controlled trial to resolve this question. Hence, a quantitative and qualitative meta-analysis was essential to evaluate the differences in these two types of hemostasis method. METHOD The major electronic databases, including Pubmed, Embase, Cochrane library, Google Scholar, China National Knowledge Infrastructure and Chinese Scientific and Technological Journal databases were using the key words "electrocautery", "electrocoagulation", "harmonic scalpel", "ultrasonic scalpel", "ultrasonic dissector", "parotidectomy" and "parotid surgery". 9 articles were included in our systematic review and meta-analysis. The operative time, intraoperative blood loss, hospital stay, salivary fistula and transient facial nerve paralysis were the outcome measures. Odds ratios (ORs) with 95% confidence intervals (CIs) were employed to evaluate the effect size for categorical outcomes and mean differences (MDs) with 95% confidence intervals (CIs) for continuous outcomes. RESULTS In our meta-analysis, there was a significant reduction in operation time [mean difference: -20.97; 95%CI=(-24.02,-17.92); P < 0.00001], intraoperative blood loss [mean difference: -20.75, 95%CI=(-22.32,-19.18); P < 0.00001], hospital stay [mean difference: -0.83; 95%CI=(-1.10,-0.57); P < 0.00001], salivary fistula [ORs: 0.30, 95%CI=(0.08,1.14)] and transient facial nerve paralysis [OR:0.33, 95%CI=(0.19,0.58),P = 0.0001] in harmonic scalpel group compared with electrocautery group. CONCLUSION This meta-analysis indicated that compared with electrocautery, harmonic scalpel (HS)was transcendent in the aspects of operative time, intraoperative blood loss, hospital stay, salivary fistula and transient facial nerve paralysis. The harmonic scalpel, as an efficient and useful instrument, was advocated in parotidectomy.
Collapse
Affiliation(s)
- Delong Li
- Department of Oral and Maxillofacial Surgery, School of Stomatology, China Medical University, 117 Nanjing Bei Jie, Heping, Shenyang, Liaoning 110002, PR China.
| | - Yurong Kou
- Department of Oral and Maxillofacial Surgery, School of Stomatology, China Medical University, 117 Nanjing Bei Jie, Heping, Shenyang, Liaoning 110002, PR China.
| | - Shaohui Huang
- Department of Oral and Maxillofacial Surgery, School of Stomatology, China Medical University, 117 Nanjing Bei Jie, Heping, Shenyang, Liaoning 110002, PR China.
| | - Zechen Wang
- Department of Oral and Maxillofacial Surgery, School of Stomatology, China Medical University, 117 Nanjing Bei Jie, Heping, Shenyang, Liaoning 110002, PR China.
| | - Chunliu Ning
- Department of Oral and Maxillofacial Surgery, School of Stomatology, China Medical University, 117 Nanjing Bei Jie, Heping, Shenyang, Liaoning 110002, PR China.
| | - Tengfei Zhao
- Department of Oral and Maxillofacial Surgery, School of Stomatology, China Medical University, 117 Nanjing Bei Jie, Heping, Shenyang, Liaoning 110002, PR China.
| |
Collapse
|
18
|
Cheng H, Clymer JW, Qadeer RA, Ferko N, Sadeghirad B, Cameron CG, Amaral JF. Procedure costs associated with the use of Harmonic devices compared to conventional techniques in various surgeries: a systematic review and meta-analysis. CLINICOECONOMICS AND OUTCOMES RESEARCH 2018; 10:399-412. [PMID: 30087572 PMCID: PMC6063248 DOI: 10.2147/ceor.s164747] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022] Open
Abstract
Background As compared to conventional techniques, recent meta-analyses have reported cost savings with Harmonic devices; however, only in thyroidectomy. Thus, the aim of this study was to evaluate the costs associated with Harmonic devices versus conventional techniques across a range of surgical procedures. Methods A systematic search of MEDLINE, EMBASE, and Cochrane Library was conducted from inception to October 01, 2016 without language restrictions to identify randomized controlled trials comparing Harmonic devices to conventional techniques and reporting procedure costs (operating time plus operating equipment/consumables/device costs). Costs were pooled using the ratio of geometric means, and a random effects model was applied. Sensitivity analyses varying statistical methods, number of included studies, and cost outcomes were completed to test the robustness of the results. Results Thirteen studies met the inclusion criteria. A total of 561 and 540 participants had procedures performed with Harmonic devices and conventional methods, respectively, with procedures including gastrectomy, thyroidectomy, colectomy, cholecystectomy, Nissen fundoplication, and pancreaticoduodenectomy. As compared to conventional methods, Harmonic devices reduced total procedure costs by 8.7% (p=0.029), resulting in an absolute reduction of US$227.77 from mean conventional technique costs, derived primarily from a reduction in operating time costs. When operating time costs, excluding operating equipment/consumables/device costs, were analyzed, costs were reduced by $544 per procedure with the use of Harmonic devices. The results from all sensitivity analyses demonstrated cost reductions with Harmonic devices. Conclusion This systematic review and meta-analysis showed that despite a higher device cost, Harmonic devices provide a statistically significant reduction in procedure costs, derived primarily from a reduction in operating time costs, across surgical procedures. In addition to functionality benefits, Harmonic devices may represent a potentially cost saving method to reduce overall hospital resource use. Future research should focus on potential costs and benefits from use of Harmonic devices in procedures not covered here.
Collapse
Affiliation(s)
| | | | | | - Nicole Ferko
- Cornerstone Research Group, Burlington, ON, Canada,
| | | | | | | |
Collapse
|
19
|
Aires FT, Matos LLD, Dedivitis RA, Cernea CR. Effectiveness of harmonic scalpel in patients submitted to total thyroidectomy: systematic review with meta-analysis. Rev Assoc Med Bras (1992) 2018; 64:649-657. [DOI: 10.1590/1806-9282.64.07.649] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2017] [Accepted: 12/06/2017] [Indexed: 11/22/2022] Open
|
20
|
Camenzuli C, Schembri Wismayer P, Calleja Agius J. Transoral Endoscopic Thyroidectomy: A Systematic Review of the Practice So Far. JSLS 2018; 22:e2018.00026. [PMID: 30275676 PMCID: PMC6158973 DOI: 10.4293/jsls.2018.00026] [Citation(s) in RCA: 45] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022] Open
Abstract
Background and Objectives Thyroid disease largely affects young females, but the incidence is also increasing among males. In an effort to avoid the scarring of the neck that is synonymous with conventional thyroidectomy, endoscopic techniques have been developed over the years. The transoral endoscopic approach is the latest of these innovations that promises a scarless surgical outcome. This review evaluates whether this technique is safe and feasible in live patients and outlines the outcomes in published literature so far. Database PubMed, Medline, BioMed Central, Cochrane Library, OVID and Web of Science were systematically searched by using a Medical Subject Heading (MeSH)-optimized search strategy. The selection of papers followed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines after setting strict inclusion and exclusion criteria. Sixteen studies were included in the final analysis. Discussion This systematic review presents cases of 785 patients. Surgeons in 15 of the studies used a completely vestibular approach, whereas those in the remaining 2 used the floor of the mouth for primary access. Conversion to open surgery took place in 1.3%. In total, 4.3% of patients experienced transient laryngeal nerve palsy, whereas 0.1% had permanent recurrent incidences of the condition. Transient hypocalcemia occurred in 7.4% of cases, with no recorded permanent cases. Carbon dioxide embolism occurred in 0.6% of cases, and another 0.6% had a deep-seated neck infection. The complication rates within the review were deemed acceptable and the overall technique feasible. A prospective randomized controlled trial was proposed to compare this technique with conventional thyroidectomy.
Collapse
Affiliation(s)
- Christian Camenzuli
- Department of Anatomy, Faculty of Medicine and Surgery, Biomedical Sciences, University of Malta, Msida, Malta
| | - Pierre Schembri Wismayer
- Department of Anatomy, Faculty of Medicine and Surgery, Biomedical Sciences, University of Malta, Msida, Malta
| | - Jean Calleja Agius
- Department of Anatomy, Faculty of Medicine and Surgery, Biomedical Sciences, University of Malta, Msida, Malta
| |
Collapse
|
21
|
Maeda H, Kutomi G, Satomi F, Shima H, Mori M, Takemasa I. Comparison of surgical outcomes and complications between the Harmonic FOCUS and conventional surgery for open thyroidectomy. Mol Clin Oncol 2018. [PMID: 29541464 DOI: 10.3892/mco.2018.1569] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
The aim of the present study was to evaluate the potential advantages of the ultrasonic scalpel compared with the conventional technique in thyroid surgery. Patients with resectable thyroid cancer and Basedow's disease were assigned to ultrasonic scalpel or conventional technique (knot-tying and electrocoagulation). The present study used the Harmonic FOCUS® (HF) as an ultrasonic scalpel. Between February 2013 and May 2016, 45 patients were enrolled into the study. Duration of the surgery was significantly decreased in the HF group compared with the conventional surgery (CS) group (median 142 vs. 151 min; P=0.0406). Intraoperative blood loss and total volume of drainage fluid were significantly decreased in the HF group compared with the CS group (median 40 vs. 125 ml; P=0.0054, and median 120 vs. 175.5 ml; P=0.0490). Duration of drain placement and length of hospitalization stay were similar in the two groups. Furthermore, the overall incidence of postoperative complications did not differ between the two groups. Overall, the present study suggests that open thyroidectomy using the HF is safe and effective and not associated with any increase in complications.
Collapse
Affiliation(s)
- Hideki Maeda
- Department of Surgery, Surgical Oncology and Science, Sapporo Medical University, Sapporo, Hokkaido 060-8543, Japan
| | - Goro Kutomi
- Department of Surgery, Surgical Oncology and Science, Sapporo Medical University, Sapporo, Hokkaido 060-8543, Japan
| | - Fukino Satomi
- Department of Surgery, Surgical Oncology and Science, Sapporo Medical University, Sapporo, Hokkaido 060-8543, Japan
| | - Hiroaki Shima
- Department of Surgery, Surgical Oncology and Science, Sapporo Medical University, Sapporo, Hokkaido 060-8543, Japan
| | - Mitsuru Mori
- Department of Public Health, Sapporo Medical University, Sapporo, Hokkaido 060-8556, Japan
| | - Ichiro Takemasa
- Department of Surgery, Surgical Oncology and Science, Sapporo Medical University, Sapporo, Hokkaido 060-8543, Japan
| |
Collapse
|
22
|
Aleksandar K, Miodagl D, Nebojsa D, Ilija G. Effect of fibrin vs cellulose based haemostatic agents with traditional haemostatic procedures in thyroid surgery. Pak J Med Sci 2018; 33:1360-1365. [PMID: 29492059 PMCID: PMC5768825 DOI: 10.12669/pjms.336.13692] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022] Open
Abstract
Objective: To compare the efficacy of fibrin-based hemostat and cellulose-based hemostat with traditional procedures in patients undergoing thyroid surgery. Methods: Between January 2012 and December 2016, 255 patients were scheduled to undergo total thyroidectomy at Surgical Clinic Nis. The patients were randomized to: Group-I use of classic surgical procedures to achieve hemostasis, Group-II use Surgicel and Group-III use Beriplas Results: A statistically significant reduction of surgical time was found for Group-I compared with Group-II and III (p≤0.01 for both groups). Statistically significant reduction of intraoperative blood loss was found for Group-I compared with Group-II from 102.3mL vs. 86.1mL (p≤0.01) as well as compared to Group-III (mean 77.4mL, p≤0.01). Removal of the wound drain occurred sooner in the Group-II and III compared with Group-I (mean 37.1h vs. 40.1h, p≤0.05; mean 31.2h vs. 40.1h, p≤0.01). There were no significant differences in terms of postoperative morbidity among the groups. Conclusions: Fibrin based haemostat seems to be an effective hemostatic agent for patients undergoing thyroid surgery. We suggest that, where appropriate, this fibrin-based haemostat should be used as a first line hemostatic agent in thyroidectomy in combination with conventional surgical means of hemostasis.
Collapse
Affiliation(s)
- Karanikolic Aleksandar
- Dr. Karanikolic Aleksandar, MD, PhD. Medical Faculty Nis, University of Nis, Serbia. Surgical Clinic, Clinical center Nis, Serbia
| | - Djordjevic Miodagl
- Dr. Djordjevic Miodag, MD. Medical Faculty Nis, University of Nis, Serbia. Surgical Clinic, Clinical center Nis, Serbia
| | - Djordjevic Nebojsa
- Prof. Dr. Djordjevic Nebojsa, MD, PhD. Medical Faculty Nis, University of Nis, Serbia. Surgical Clinic, Clinical center Nis, Serbia
| | - Golubovic Ilija
- Dr. Golubovic Ilija MD. Surgical Clinic, Clinical center Nis, Serbia
| |
Collapse
|
23
|
Advanced vessel sealing devices in total thyroidectomy for substernal goitre: A retrospective cohort study. Int J Surg 2016; 35:160-164. [DOI: 10.1016/j.ijsu.2016.09.092] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2016] [Revised: 08/31/2016] [Accepted: 09/24/2016] [Indexed: 02/03/2023]
|
24
|
Dionigi G, Chiang FY, Kim HY, Randolph GW, Mangano A, Chang PY, Lu IC, Lin YC, Chen HC, Wu CW. Safety of LigaSure in recurrent laryngeal nerve dissection-porcine model using continuous monitoring. Laryngoscope 2016; 127:1724-1729. [PMID: 27578605 DOI: 10.1002/lary.26271] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2016] [Revised: 07/19/2016] [Accepted: 08/02/2016] [Indexed: 12/29/2022]
Abstract
OBJECTIVES/HYPOTHESIS This study investigated recurrent laryngeal nerve (RLN) real-time electromyography (EMG) data to define optimal safety parameters of the LigaSure Small Jaw (LSJ) instrument during thyroidectomy. STUDY DESIGN Prospective animal model. METHODS Dynamic EMG tracings were recorded from 32 RLNs (16 piglets) during various applications of LSJ around using continuous electrophysiologic monitoring. At varying distances from the RLN, the LSJ was activated (activation study). The LSJ was also applied to the RLN at timed intervals after activation and after a cooling maneuver through placement on the sternocleidomastoid muscle (cooling study). RESULTS In the activation study, there was no adverse EMG event at 2 to 5 mm distance (16 RLNs, 96 tests). In the cooling study, there was no adverse EMG event after 2-second cooling time (16 RLNs, 96 tests) or after the LSJ cooling maneuver on the surrounding muscle before reaching the RLNs (8 RLNs, 24 tests). CONCLUSION Based on EMG functional assessment, the safe distance for LSJ activation was 2 mm. Further LSJ-RLN contact was safe if the LSJ was cooled for more than 2 seconds or cooled by touch muscle maneuver. The LSJ should be used with these distance and time parameters in mind to avoid RLN injury. LEVEL OF EVIDENCE N/A. Laryngoscope, 127:1724-1729, 2017.
Collapse
Affiliation(s)
- Gianlorenzo Dionigi
- 1st Division of Surgery, Research Center for Endocrine Surgery, Department of Surgical Sciences and Human Morphology, University of Insubria (Como-Varese), Varese, Italy
| | - Feng-Yu Chiang
- Department of Otolaryngology-Head and Neck Surgery, Kaohsiung Medical University Hospital, Kaohsiung, Taiwan.,Faculty of Medicine, College of Medicine, Kaohsiung Medical University, Kaohsiung, Taiwan
| | - Hoon Yub Kim
- Department of Surgery, KUMC Thyroid Center, Korea University Anam Hospital, Korea University College of Medicine, Seoul, Republic of Korea
| | - Gregory W Randolph
- Division of Thyroid and Parathyroid Endocrine Surgery, Department of Laryngology and Otology, Massachusetts Eye and Ear Infirmary, Harvard Medical School, Boston, U.S.A
| | - Alberto Mangano
- 1st Division of Surgery, Research Center for Endocrine Surgery, Department of Surgical Sciences and Human Morphology, University of Insubria (Como-Varese), Varese, Italy
| | - Pi-Ying Chang
- Department of Anesthesiology, Kaohsiung Medical University Hospital, Kaohsiung, Taiwan
| | - I-Cheng Lu
- Department of Anesthesiology, Kaohsiung Medical University Hospital, Kaohsiung, Taiwan
| | - Yi-Chu Lin
- Department of Otolaryngology-Head and Neck Surgery, Kaohsiung Medical University Hospital, Kaohsiung, Taiwan.,Faculty of Medicine, College of Medicine, Kaohsiung Medical University, Kaohsiung, Taiwan
| | - Hui-Chun Chen
- Department of Nursing, Kaohsiung Medical University Hospital, Kaohsiung, Taiwan
| | - Che-Wei Wu
- Department of Otolaryngology-Head and Neck Surgery, Kaohsiung Medical University Hospital, Kaohsiung, Taiwan.,Faculty of Medicine, College of Medicine, Kaohsiung Medical University, Kaohsiung, Taiwan
| |
Collapse
|
25
|
PARDAL-REFOYO JL. Evidencia y recomendación. ¿Harmonic Ultracision ofrece ventajas en tiroidectomía? REVISTA ORL 2016. [DOI: 10.14201/orl201674.14804] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022] Open
|