Hady TF, Hwang B, Waworuntu RL, Ratner BD, Bryers JD. Cells resident to precision templated 40-µm pore scaffolds generate small extracellular vesicles that affect CD4 + T cell phenotypes through regulatory TLR4 signaling. Acta Biomater 2023; 166:119-132. [PMID: 37150279 PMCID: PMC10330460 DOI: 10.1016/j.actbio.2023.05.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2023] [Revised: 04/27/2023] [Accepted: 05/02/2023] [Indexed: 05/09/2023]
Abstract
Precision porous templated scaffolds (PTS) are a hydrogel construct of uniformly sized interconnected spherical pores that induce a pro-healing response (reducing the foreign body reaction, FBR) exclusively when the pores are 30-40µm in diameter. Our previous work demonstrated the necessity of Tregs in the maintenance of PTS pore size specific differences in CD4+ T cell phenotype. Work here characterizes the role of Tregs in the responses to implanted 40µm and 100µm PTS using WT and FoxP3+ cell (Treg) depleted mice. Proteomic analyses indicate that integrin signaling, monocytes/macrophages, cytoskeletal remodeling, inflammatory cues, and vesicule endocytosis may participate in Treg activation and the CD4+ T cell equilibrium modulated by PTS resident cell-derived small extracellular vesicles (sEVs). The role of MyD88-dependent and MyD88-independent TLR4 activation in PTS cell-derived sEV-to-T cell signaling is quantified by treating WT, TLR4ko, and MyD88ko splenic T cells with PTS cell-derived sEVs. STAT3 and mTOR are identified as mechanisms for further study for pore-size dependent PTS cell-derived sEV-to-T cell signaling. STATEMENT OF SIGNIFICANCE: Unique cell populations colonizing only within 40µm pore size PTS generate sEVs that resolve inflammation by modifying CD4+ T cell phenotypes through TLR4 signaling.
Collapse
Affiliation(s)
- T F Hady
- Department of Bioengineering, University of Washington, Seattle, WA 98105, USA
| | - B Hwang
- Center for Lung Biology, Department of Surgery, University of Washington Seattle, WA 98109, USA
| | - R L Waworuntu
- Center for Lung Biology, Department of Surgery, University of Washington Seattle, WA 98109, USA
| | - B D Ratner
- Department of Bioengineering, University of Washington, Seattle, WA 98105, USA
| | - J D Bryers
- Department of Bioengineering, University of Washington, Seattle, WA 98105, USA.
| |
Collapse
|
2
|
Hady TF, Hwang B, Pusic AD, Waworuntu RL, Mulligan M, Ratner B, Bryers JD. Uniform 40-µm-pore diameter precision templated scaffolds promote a pro-healing host response by extracellular vesicle immune communication. J Tissue Eng Regen Med 2020; 15:24-36. [PMID: 33217150 DOI: 10.1002/term.3160] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2020] [Revised: 09/23/2020] [Accepted: 10/12/2020] [Indexed: 02/06/2023]
Abstract
Implanted porous precision templated scaffolds (PTS) with 40-µm spherical pores reduce inflammation and foreign body reaction (FBR) while increasing vascular density upon implantation. Larger or smaller pores, however, promote chronic inflammation and FBR. While macrophage (MØ) recruitment and polarization participates in perpetuating this pore-size-mediated phenomenon, the driving mechanism of this unique pro-healing response is poorly characterized. We hypothesized that the primarily myeloid PTS resident cells release small extracellular vesicles (sEVs) that induce pore-size-dependent pro-healing effects in surrounding T cells. Upon profiling resident immune cells and their sEVs from explanted 40-µm- (pro-healing) and 100-µm-pore diameter (inflammatory) PTS, we found that PTS pore size did not affect PTS resident immune cell population ratios or the proportion of myeloid sEVs generated from explanted PTS. However, quantitative transcriptomic assessment indicated cell and sEV phenotype were pore size dependent. In vitro experiments demonstrated the ability of PTS cell-derived sEVs to stimulate T cells transcriptionally and proliferatively. Specifically, sEVs isolated from cells inhabiting explanted 100 μm PTS significantly upregulated Th1 inflammatory gene expression in immortalized T cells. sEVs isolated from cell inhabiting both 40- and 100-μm PTS upregulated essential Treg transcriptional markers in both primary and immortalized T cells. Finally, we investigated the effects of Treg depletion on explanted PTS resident cells. FoxP3+ cell depletion suggests Tregs play a unique role in balancing T cell subset ratios, thus driving host response in 40-μm PTS. These results indicate that predominantly 40-µm PTS myeloid cell-derived sEVs affect T cells through a distinct, pore-size-mediated modality.
Collapse
Affiliation(s)
- Thomas F Hady
- Department of Bioengineering, University of Washington, Seattle, Washington, USA
| | - Billanna Hwang
- Center for Lung Biology, Department of Surgery, University of Washington, Seattle, Washington, USA.,West Coast Exosortium (Westco Exosortium), University of Washington, Seattle, Washington, USA
| | - A D Pusic
- Department of Bioengineering, University of Washington, Seattle, Washington, USA
| | - Racheal L Waworuntu
- Center for Lung Biology, Department of Surgery, University of Washington, Seattle, Washington, USA
| | - Michael Mulligan
- Center for Lung Biology, Department of Surgery, University of Washington, Seattle, Washington, USA.,West Coast Exosortium (Westco Exosortium), University of Washington, Seattle, Washington, USA
| | - Buddy Ratner
- Department of Bioengineering, University of Washington, Seattle, Washington, USA
| | - James D Bryers
- Department of Bioengineering, University of Washington, Seattle, Washington, USA.,West Coast Exosortium (Westco Exosortium), University of Washington, Seattle, Washington, USA
| |
Collapse
|
3
|
Abdallah MN, Badran Z, Ciobanu O, Hamdan N, Tamimi F. Strategies for Optimizing the Soft Tissue Seal around Osseointegrated Implants. Adv Healthc Mater 2017; 6. [PMID: 28960892 DOI: 10.1002/adhm.201700549] [Citation(s) in RCA: 34] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2017] [Revised: 07/12/2017] [Indexed: 12/20/2022]
Abstract
Percutaneous and permucosal devices such as catheters, infusion pumps, orthopedic, and dental implants are commonly used in medical treatments. However, these useful devices breach the soft tissue barrier that protects the body from the outer environment, and thus increase bacterial infections resulting in morbidity and mortality. Such associated infections can be prevented if these devices are effectively integrated with the surrounding soft tissue, and thus creating a strong seal from the surrounding environment. However, so far, there are no percutaneous/permucosal medical devices able to prevent infection by achieving strong integration at the soft tissue-device interface. This review gives an insight into the current status of research into soft tissue-implant interface and the challenges associated with these interfaces. Biological soft/hard tissue interfaces may provide insights toward engineering better soft tissue interfaces around percutaneous devices. In this review, focus is put on the history and current findings as well as recent progress of the strategies aiming to develop a strong soft tissue seal around osseointegrated implants, such as orthopedic and dental implants.
Collapse
Affiliation(s)
- Mohamed-Nur Abdallah
- Division of Biomedical Sciences; Faculty of Dentistry; McGill University; Montreal H3A 1G1 QC Canada
- Division of Orthodontics; Faculty of Dentistry; Toronto University; Toronto M5G 1G6 ON Canada
| | - Zahi Badran
- Division of Biomedical Sciences; Faculty of Dentistry; McGill University; Montreal H3A 1G1 QC Canada
- Department of Periodontology (CHU/Rmes Inserm U1229/UIC11); Faculty of Dental Surgery; University of Nantes; Nantes 44042 France
| | - Ovidiu Ciobanu
- Division of Biomedical Sciences; Faculty of Dentistry; McGill University; Montreal H3A 1G1 QC Canada
| | - Nader Hamdan
- Department of Dental Clinical Sciences; Faculty of Dentistry; Dalhousie University; Halifax B3H 4R2 NS Canada
| | - Faleh Tamimi
- Division of Biomedical Sciences; Faculty of Dentistry; McGill University; Montreal H3A 1G1 QC Canada
| |
Collapse
|
4
|
Nam K, Matsushima R, Kimura T, Fujisato T, Kishida A. In Vivo Characterization of a Decellularized Dermis-Polymer Complex for Use in Percutaneous Devices. Artif Organs 2014; 38:1060-5. [DOI: 10.1111/aor.12330] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Affiliation(s)
- Kwangwoo Nam
- Institute of Biomaterials and Bioengineering; Tokyo Medical and Dental University; Tokyo Japan
- CREST; Japan Science and Technology Agency; Tokyo Japan
| | - Rie Matsushima
- Institute of Biomaterials and Bioengineering; Tokyo Medical and Dental University; Tokyo Japan
| | - Tsuyoshi Kimura
- Institute of Biomaterials and Bioengineering; Tokyo Medical and Dental University; Tokyo Japan
- CREST; Japan Science and Technology Agency; Tokyo Japan
| | - Toshiya Fujisato
- Department of Biomedical Engineering; Osaka Institute of Technology; Osaka Japan
| | - Akio Kishida
- Institute of Biomaterials and Bioengineering; Tokyo Medical and Dental University; Tokyo Japan
- CREST; Japan Science and Technology Agency; Tokyo Japan
| |
Collapse
|
5
|
Betz DH, Epperson RT, Holt BM, Bloebaum RD, Jeyapalina S. A new trichrome technique for PMMA embedded percutaneous implants for the study and characterization of epithelial integration. J Histotechnol 2013. [DOI: 10.1179/2046023612y.0000000016] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/31/2022]
|
6
|
Farrell BJ, Prilutsky BI, Ritter JM, Kelley S, Popat K, Pitkin M. Effects of pore size, implantation time, and nano-surface properties on rat skin ingrowth into percutaneous porous titanium implants. J Biomed Mater Res A 2013; 102:1305-15. [PMID: 23703928 DOI: 10.1002/jbm.a.34807] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2013] [Revised: 05/13/2013] [Accepted: 05/15/2013] [Indexed: 11/10/2022]
Abstract
The main problem of percutaneous osseointegrated implants is poor skin-implant integration, which may cause infection. This study investigated the effects of pore size (Small, 40-100 μm and Large, 100-160 μm), nanotubular surface treatment (Nano), and duration of implantation (3 and 6 weeks) on skin ingrowth into porous titanium. Each implant type was percutaneously inserted in the back of 35 rats randomly assigned to seven groups. Implant extrusion rate was measured weekly and skin ingrowth into implants was determined histologically after harvesting implants. It was found that all three types of implants demonstrated skin tissue ingrowth of over 30% (at week 3) and 50% (at weeks 4-6) of total implant porous area under the skin; longer implantation resulted in greater skin ingrowth (p < 0.05). Only one case of infection was observed (infection rate 2.9%). Small and Nano groups showed the same implant extrusion rate which was lower than the Large group rate (0.06 ± 0.01 vs. 0.16 ± 0.02 cm/week; p < 0.05). Ingrowth area was comparable in the Small, Large, and Nano implants. However, qualitatively, the Nano implants showed greatest cellular inhabitation within first 3 weeks. We concluded that percutaneous porous titanium implants allow for skin integration with the potential for a safe seal.
Collapse
Affiliation(s)
- Brad J Farrell
- School of Applied Physiology, Center for Human Movement Studies, Georgia Institute of Technology, Atlanta, Georgia
| | | | | | | | | | | |
Collapse
|
7
|
Palmquist A, Snis A, Emanuelsson L, Browne M, Thomsen P. Long-term biocompatibility and osseointegration of electron beam melted, free-form–fabricated solid and porous titanium alloy: Experimental studies in sheep. J Biomater Appl 2013. [DOI: 10.1177/0731684411431857] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
The purpose of the present study was to evaluate the long-term osseointegration and biocompatibility of electron beam melted (EBM) free-form–fabricated (FFF titanium grade 5 (Ti6Al4V) implants. Porous and solid machined cylindrical and disk-shaped implants were prepared by EBM and implanted bilaterally in the femur and subcutaneously in the dorsum of the sheep. After 26 weeks, the implants and surrounding tissue were retrieved. The tissue response was examined qualitatively and quantitatively using histology and light microscopic (LM) morphometry. Selected bone implants specimens were evaluated by scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDS), and micro-computed tomography (mCT). The results showed that both porous and solid implants were osseointegrated and high bone–implant contact was observed throughout the porous implant. In the soft tissue, the porous implants showed thinner fibrous encapsulation while no signs of intolerance were observed for either implant type. Taken together, the present experimental results show that FFF Ti6Al4V with and without porous structures demonstrate excellent long-term soft tissue biocompatibility and a high degree of osseointegration. The present findings extend earlier, short-term experimental observations in bone and suggest that EBM, FFF Ti6Al4V implants possess valuable properties in bone and soft tissue applications.
Collapse
Affiliation(s)
- A Palmquist
- Department of Biomaterials, Sahlgrenska Academy at University of Gothenburg Göteborg, Sweden
- BIOMATCELL VINN Excellence Center of Biomaterials and Cell Therapy Göteborg, Sweden
| | - A Snis
- BIOMATCELL VINN Excellence Center of Biomaterials and Cell Therapy Göteborg, Sweden
- Arcam AB Mölndal, Sweden
| | - L Emanuelsson
- Department of Biomaterials, Sahlgrenska Academy at University of Gothenburg Göteborg, Sweden
- BIOMATCELL VINN Excellence Center of Biomaterials and Cell Therapy Göteborg, Sweden
| | - M Browne
- Bioengineering Group, School of Engineering Sciences, University of Southampton UK
| | - P Thomsen
- Department of Biomaterials, Sahlgrenska Academy at University of Gothenburg Göteborg, Sweden
- BIOMATCELL VINN Excellence Center of Biomaterials and Cell Therapy Göteborg, Sweden
| |
Collapse
|
8
|
Bryers JD, Giachelli CM, Ratner BD. Engineering biomaterials to integrate and heal: the biocompatibility paradigm shifts. Biotechnol Bioeng 2012; 109:1898-911. [PMID: 22592568 PMCID: PMC3490630 DOI: 10.1002/bit.24559] [Citation(s) in RCA: 172] [Impact Index Per Article: 14.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2012] [Revised: 04/27/2012] [Accepted: 05/10/2012] [Indexed: 12/19/2022]
Abstract
This article focuses on one of the major failure routes of implanted medical devices, the foreign body reaction (FBR)--that is, the phagocytic attack and encapsulation by the body of the so-called "biocompatible" biomaterials comprising the devices. We then review strategies currently under development that might lead to biomaterial constructs that will harmoniously heal and integrate into the body. We discuss in detail emerging strategies to inhibit the FBR by engineering biomaterials that elicit more biologically pertinent responses.
Collapse
Affiliation(s)
- James D Bryers
- Department of Bioengineering, University of Washington, Seattle, WA 98195-5061, USA.
| | | | | |
Collapse
|
9
|
Fleckman P, Usui M, Zhao G, Underwood R, Maginness M, Marshall A, Glaister C, Ratner B, Olerud J. Cutaneous and inflammatory response to long-term percutaneous implants of sphere-templated porous/solid poly(HEMA) and silicone in mice. J Biomed Mater Res A 2012; 100:1256-68. [PMID: 22359383 DOI: 10.1002/jbm.a.34012] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2011] [Revised: 10/17/2011] [Accepted: 10/24/2011] [Indexed: 11/10/2022]
Abstract
This study investigates mouse cutaneous responses to long-term percutaneously implanted rods surrounded by sphere-templated porous biomaterials engineered to mimic medical devices surrounded by a porous cuff. We hypothesized that keratinocytes would migrate through the pores and stop, permigrate, or marsupialize along the porous/solid interface. Porous/solid-core poly(2-hydroxyethyl methacrylate) [poly(HEMA)] and silicone rods were implanted in mice for 14 days, and for 1, 3, and 6 months. Implants with surrounding tissue were analyzed (immuno)histochemically by light microscopy. Poly(HEMA)/skin implants yielded better morphologic data than silicone implants. Keratinocytes at the poly(HEMA) interface migrated in two different directions. "Ventral" keratinocytes contiguous with the dermal-epidermal junction migrated into the outermost pores, forming an integrated collar surrounding the rods. "Dorsal" keratinocytes appearing to emanate from the differentiated epithelial layer, extended upward along and into the exterior portion of the rod, forming an integrated sheath. Leukocytes persisted in poly(HEMA) and silicone pores for the duration of the study. Vascular and collagen networks within the poly(HEMA) pores matured as a function of time up to 3-months implantation. Nerves were not observed within the pores. Poly(HEMA) underwent morphological changes by 6 months of implantation. Marsupialization, foreign body encapsulation, and infection were not observed in any implants.
Collapse
Affiliation(s)
- Philip Fleckman
- Department of Medicine (Dermatology), University of Washington, Seattle, Washington, USA.
| | | | | | | | | | | | | | | | | |
Collapse
|
10
|
Yerneni S, Dhaher Y, Kuiken TA. A computational model for stress reduction at the skin-implant interface of osseointegrated prostheses. J Biomed Mater Res A 2012; 100:911-7. [DOI: 10.1002/jbm.a.34028] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2011] [Revised: 06/13/2011] [Accepted: 11/11/2011] [Indexed: 11/10/2022]
|
11
|
Palmquist A, Snis A, Emanuelsson L, Browne M, Thomsen P. Long-term biocompatibility and osseointegration of electron beam melted, free-form-fabricated solid and porous titanium alloy: experimental studies in sheep. J Biomater Appl 2011; 27:1003-16. [PMID: 22207608 DOI: 10.1177/0885328211431857] [Citation(s) in RCA: 73] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
The purpose of the present study was to evaluate the long-term osseointegration and biocompatibility of electron beam melted (EBM) free-form-fabricated (FFF titanium grade 5 (Ti6Al4V) implants. Porous and solid machined cylindrical and disk-shaped implants were prepared by EBM and implanted bilaterally in the femur and subcutaneously in the dorsum of the sheep. After 26 weeks, the implants and surrounding tissue were retrieved. The tissue response was examined qualitatively and quantitatively using histology and light microscopic (LM) morphometry. Selected bone implants specimens were evaluated by scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDS), and micro-computed tomography (mCT). The results showed that both porous and solid implants were osseointegrated and high bone-implant contact was observed throughout the porous implant. In the soft tissue, the porous implants showed thinner fibrous encapsulation while no signs of intolerance were observed for either implant type. Taken together, the present experimental results show that FFF Ti6Al4V with and without porous structures demonstrate excellent long-term soft tissue biocompatibility and a high degree of osseointegration. The present findings extend earlier, short-term experimental observations in bone and suggest that EBM, FFF Ti6Al4V implants possess valuable properties in bone and soft tissue applications.
Collapse
Affiliation(s)
- A Palmquist
- Department of Biomaterials, Sahlgrenska Academy at University of Gothenburg, Göteborg, Sweden.
| | | | | | | | | |
Collapse
|
12
|
Underwood RA, Usui ML, Zhao G, Hauch KD, Takeno MM, Ratner BD, Marshall AJ, Shi X, Olerud JE, Fleckman P. Quantifying the effect of pore size and surface treatment on epidermal incorporation into percutaneously implanted sphere-templated porous biomaterials in mice. J Biomed Mater Res A 2011; 98:499-508. [PMID: 21681942 DOI: 10.1002/jbm.a.33125] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2010] [Revised: 03/05/2011] [Accepted: 03/18/2011] [Indexed: 11/08/2022]
Abstract
The sinus between skin and a percutaneous medical device is often a portal for infection. Epidermal integration into an optimized porous biomaterial could seal this sinus. In this study, we measured epithelial ingrowth into rods of sphere-templated porous poly(2-hydroxyethyl methacrylate) implanted percutaneously in mice. The rods contained spherical 20-, 40-, or 60-μm pores with and without surface modification. Epithelial migration was measured 3, 7, and 14 days post-implantation utilizing immunohistochemistry for pankeratins and image analysis. Our global results showed average keratinocyte migration distances of 81 ± 16.85 μm (SD). Migration was shorter through 20-μm pores (69.32 ± 21.73) compared with 40 and 60 μm (87.04 ± 13.38 μm and 86.63 ± 8.31 μm, respectively). Migration was unaffected by 1,1' carbonyldiimidazole surface modification without considering factors of pore size and healing duration. Epithelial integration occurred quickly showing an average migration distance of 74.13 ± 12.54 μm after 3 days without significant progression over time. These data show that the epidermis closes the sinus within 3 days, migrates into the biomaterial (an average of 11% of total rod diameter), and stops. This process forms an integrated epithelial collar without evidence of marsupialization or permigration.
Collapse
Affiliation(s)
- Robert A Underwood
- Department of Medicine/Division of Dermatology, University of Washington, Seattle, Washington, USA.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
13
|
Fukano Y, Usui ML, Underwood RA, Isenhath S, Marshall AJ, Hauch KD, Ratner BD, Olerud JE, Fleckman P. Epidermal and dermal integration into sphere-templated porous poly(2-hydroxyethyl methacrylate) implants in mice. J Biomed Mater Res A 2010; 94:1172-86. [PMID: 20694984 DOI: 10.1002/jbm.a.32798] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023]
Abstract
Percutaneous medical devices remain susceptible to infection and failure. We hypothesize that healing of the skin into the percutaneous device will provide a seal, preventing bacterial attachment, biofilm formation, and subsequent device failure. Porous poly(2-hydroxyethyl methacrylate) [poly(HEMA)] with sphere-templated pores (40 microm) and interconnecting throats (16 microm) were implanted in normal C57BL/6 mice for 7, 14, and 28 days. Poly(HEMA) was either untreated, keeping the surface nonadhesive for cells and proteins, or modified with carbonyldiimidazole (CDI) or CDI reacted with laminin 332 to enhance adhesion. No clinical signs of infection were observed. Epidermal and dermal response within the poly(HEMA) pores was evaluated using light and transmission electron microscopy. Cells (keratinocytes, fibroblasts, endothelial cells, inflammatory cells) and basement membrane proteins (laminin 332, beta4 integrin, type VII collagen) could be demonstrated within the poly(HEMA) pores of all implants. Blood vessels and dermal collagen bundles were evident in all of the 14- and 28-day implants. Fibrous capsule formation and permigration were not observed. Sphere-templated polymers with 40 microm pores demonstrate an ability to recapitulate key elements of both the dermal and the epidermal layers of skin. Our morphological findings indicate that the implant model can be used to study the effects of biomaterial pore size, pore interconnect (throat) size, and surface treatments on cutaneous biointegration. Further, this model may be used for bacterial challenge studies.
Collapse
Affiliation(s)
- Y Fukano
- Department of Medicine (Dermatology), University of Washington, Seattle, Washington, USA
| | | | | | | | | | | | | | | | | |
Collapse
|
14
|
|
15
|
Beckstead BL, Tung JC, Liang KJ, Tavakkol Z, Usui ML, Olerud JE, Giachelli CM. Methods to promote Notch signaling at the biomaterial interface and evaluation in a rafted organ culture model. J Biomed Mater Res A 2010; 91:436-46. [PMID: 18985776 DOI: 10.1002/jbm.a.32214] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
The Notch signaling pathway is a promising target for controlling cell fate choices at the biomaterial-tissue interface. Building on our previous work in developing Notch-signaling biomaterials, we evaluated various immobilization schemes for Notch ligands, and their effect on human foreskin keratinocytes. A peptide sequence derived from the Jagged-1 DSL-region and immobilized to poly(2-hydroxyethyl methacrylate) (polyHEMA) showed no bioactivity in relation to the Notch-CSL pathway. The full-length Jagged-1 protein immobilized directly to the polyHEMA surface showed activity in signaling the Notch-CSL pathway. However, an indirect affinity immobilization approach yielded a stronger signal. Human keratinocytes plated on bound Jagged-1 showed upregulated involucrin, keratin 10, and loricrin protein expression, with this expression being cell density-dependent. Utilizing a human foreskin rafted organ culture model as a bridge between in vitro and in vivo studies, Jagged-1-modified or control polyHEMA rods were implanted in human foreskin and cultured at the air-medium interface. Keratinocyte proliferation was suppressed and intermediate-stage differentiation promoted in Jagged-1-modified rods compared with control rods. Thus, Notch-signaling biomaterials provide a robust approach to control keratinocyte differentiation and may find application to other progenitor and stem cells.
Collapse
|
16
|
Peramo A, Marcelo CL. Bioengineering the Skin–Implant Interface: The Use of Regenerative Therapies in Implanted Devices. Ann Biomed Eng 2010; 38:2013-31. [DOI: 10.1007/s10439-010-9937-1] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2009] [Accepted: 01/17/2010] [Indexed: 11/25/2022]
|
17
|
Improved Preservation of the Tissue Surrounding Percutaneous Devices by Hyaluronic Acid and Dermatan Sulfate in a Human Skin Explant Model. Ann Biomed Eng 2009; 38:1098-110. [DOI: 10.1007/s10439-009-9872-1] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2009] [Accepted: 12/08/2009] [Indexed: 01/13/2023]
|
18
|
Peramo A, Bahng JH, Marcelo CL, Kotov N, Martin DC. In vitro integration of human skin dermis with porous cationic hydrogels. Acta Biomater 2009; 5:3337-45. [PMID: 19481182 DOI: 10.1016/j.actbio.2009.05.031] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2009] [Revised: 04/06/2009] [Accepted: 05/14/2009] [Indexed: 11/29/2022]
Abstract
Porous poly(DMAA-co-AMTAC) hydrogels, fabricated using the inverted colloid crystal method, were used to observe their integration with human skin. Full thickness human breast skin explants discarded from surgeries were cultured for up to 10days at the air-liquid interface using a Transwell culture system. Cylindrical, disk- or other shaped hydrogels were placed inside the skin explants fitting punctures produced by punch biopsies or scalpels and full section histological analysis of the skin explants with the inserted hydrogel was then performed. In addition, separated hydrogels were cultured up to 7days with human fibroblasts. The results indicate that poly(DMAA-co-AMTAC) hydrogels induce substantial extracellular matrix material deposition, maintain dermal integrity in the contact areas with the skin and permit dermal fibers to integrate into the hydrogel pores. Different types of cells remaining in the explants migrated into the hydrogels pores, including red blood cells. Fibroblasts adhered to and colonized separately cultured hydrogels. We plan to use this type of soft material as an interface to permit skin integration with percutaneous devices in contact with skin.
Collapse
Affiliation(s)
- Antonio Peramo
- Department of Materials Science and Engineering, University of Michigan, Ann Arbor, MI 48109, USA
| | | | | | | | | |
Collapse
|
19
|
Koschwanez HE, Yap FY, Klitzman B, Reichert WM. In vitro and in vivo characterization of porous poly-L-lactic acid coatings for subcutaneously implanted glucose sensors. J Biomed Mater Res A 2009; 87:792-807. [PMID: 18200540 DOI: 10.1002/jbm.a.31824] [Citation(s) in RCA: 53] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
The purpose of this study was to test the hypothesis that porous poly-L-lactic acid (PLLA) sensor coatings reduce fibrosis and promote blood microvessel formation in tissue adjacent to the sensor surface. Porous PLLA coatings were produced using ammonium bicarbonate as the gas foaming/salt leaching agent, and deployed on functional and nonfunctional sensors. The porous coatings minimally affected sensor accuracy and response rate in vitro. Three-week subcutaneous rat studies of nonfunctional glucose sensors showed the anticipated effect of porous coatings enhancing vascularity and decreasing collagen deposition. In contrast, percutaneous functional sensors with and without porous coatings showed no significant difference in terms of histology or sensor response. In spite of the observation that texturing increases the vascularity of the tissue that surrounds implanted sensors, other factors such as the additional mechanical stresses imposed by percutaneous tethering may override the beneficial effects of the porous coatings.
Collapse
Affiliation(s)
- H E Koschwanez
- Department of Biomedical Engineering, Duke University, Durham, North Carolina, USA
| | | | | | | |
Collapse
|
20
|
Olerud JE. Models for diabetic wound healing and healing into percutaneous devices. JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION 2008; 19:1007-20. [PMID: 18644227 DOI: 10.1163/156856208784909426] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/13/2023]
Abstract
Delayed healing of chronic ulcers in patients with diabetes and infections resulting from percutaneous medical devices (e.g., vascular access catheters) not only plays a major role in morbidity and mortality, but is a major burden to our healthcare system. In this paper, we review models to study diabetic wound healing and the wound-healing response associated with implanted percutaneous implants.
Collapse
Affiliation(s)
- John E Olerud
- Division of Dermatology, Department of Medicine, University of Washington, Seattle, WA 98195-6524, USA.
| |
Collapse
|
21
|
Underwood RA, Carter WG, Usui ML, Olerud JE. Ultrastructural localization of integrin subunits beta4 and alpha3 within the migrating epithelial tongue of in vivo human wounds. J Histochem Cytochem 2008; 57:123-42. [PMID: 18824633 DOI: 10.1369/jhc.2008.952176] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023] Open
Abstract
Subsequent to wounding, keratinocytes must quickly restore barrier function. In vitro wound models have served to elucidate mechanisms of epithelial closure and key roles for integrins alpha6beta4 and alpha3beta1. To extrapolate in vitro data to in vivo human tissues, we used ultrathin cryomicrotomy to simultaneously observe tissue ultrastructure and immunogold localization in unwounded skin and acute human cutaneous wounds. Localization of the beta4 integrin subunit in unwounded skin shows dominant hemidesmosomal association and minor basal keratinocyte lateral filopodic cell-cell expression. After wounding, beta4 dominantly localized to cytokeratin-rich regions (trailing edge hemidesmosomes) and minor association with lamellipodia (leading edge). beta4 colocalizes with alpha3 within filopodia juxtaposed to wound matrix, and increased concentrations of beta4 were found in cytoplasmic vesicles within basal keratinocytes of the migrating tongue. alpha3 integrin subunit dominantly localized to filopodia within basal keratinocyte lateral cell-cell interfaces in unwounded skin and both cell-cell and cell-matrix filopodic interactions in wounded skin. This study indicates that beta4 interacts with the extracellular environment through both stable and transient interactions and may be managed through a different endosomal trafficking pathway than alpha3. alpha3 integrin, despite its ability to respond to alternate ligands after wounding, does so through a single structure, the filopodia.
Collapse
Affiliation(s)
- Robert A Underwood
- University of Washington, Department of Medicine (Dermatology), Seattle, WA 98195-6524, USA.
| | | | | | | |
Collapse
|
22
|
Fleckman P, Olerud JE. Models for the histologic study of the skin interface with percutaneous biomaterials. Biomed Mater 2008; 3:034006. [PMID: 18708704 DOI: 10.1088/1748-6041/3/3/034006] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
Percutaneous devices are critical for health care. Access to tissue, vessels and internal organs afforded by these devices provides the means to treat and monitor many diseases. Unfortunately, such access is not restricted, and infection may compromise the usefulness of the device and even the life of the patient. New biomaterials offer the possibility of maintaining internal access while limiting microbial access, but understanding of the cutaneous/biomaterial interface and models to study this area are limited. This paper focuses on models useful for studying the morphology and biology of the intersection of skin and percutaneous biomaterials. An organ culture and a mouse model are described that offer promising possibilities for improved understanding of this critical interface.
Collapse
Affiliation(s)
- P Fleckman
- Division of Dermatology, University of Washington School of Medicine, Seattle, WA 98195-6524, USA.
| | | |
Collapse
|
23
|
Isenhath SN, Fukano Y, Usui ML, Underwood RA, Irvin CA, Marshall AJ, Hauch KD, Ratner BD, Fleckman P, Olerud JE. A mouse model to evaluate the interface between skin and a percutaneous device. J Biomed Mater Res A 2008; 83:915-922. [PMID: 17567856 DOI: 10.1002/jbm.a.31391] [Citation(s) in RCA: 38] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023]
Abstract
Percutaneous medical devices are integral in the management and treatment of disease. The space created between the skin and the device becomes a haven for bacterial invasion and biofilm formation and results in infection. We hypothesize that sealing this space via integration of the skin into the device will create a barrier against bacterial invasion. The purpose of this study was to develop an animal model in which the interaction between skin and biomaterials can be evaluated. Porous poly(2-hydroxyethyl methacrylate) [poly(HEMA)] rods were implanted for 7 days in the dorsal skin of C57 BL/6 mice. The porous poly(HEMA) rods were surface-modified with carbonyldiimidazole (CDI) or CDI plus laminin 5; unmodified rods served as control. Implant sites were sealed with 2-octyl cyanoacrylate; corn pads and adhesive dressings were tested for stabilization of implants. All rods remained intact for the duration of the study. There was histological evidence of both epidermal and dermal integration into all poly(HEMA) rods regardless of treatment. This in vivo model permits examination of the implant/skin interface and will be useful for future studies designed to facilitate skin cell attachment where percutaneous devices penetrate the skin.
Collapse
Affiliation(s)
- S N Isenhath
- Department of Medicine/Dermatology, University of Washington, Seattle, Washington
| | - Y Fukano
- Department of Medicine/Dermatology, University of Washington, Seattle, Washington
| | - M L Usui
- Department of Medicine/Dermatology, University of Washington, Seattle, Washington
| | - R A Underwood
- Department of Medicine/Dermatology, University of Washington, Seattle, Washington
| | - C A Irvin
- Department of BioEngineering, University of Washington, Seattle, Washington
| | - A J Marshall
- Department of BioEngineering, University of Washington, Seattle, Washington
| | - K D Hauch
- Department of BioEngineering, University of Washington, Seattle, Washington
| | - B D Ratner
- Department of BioEngineering, University of Washington, Seattle, Washington
| | - P Fleckman
- Department of Medicine/Dermatology, University of Washington, Seattle, Washington
| | - J E Olerud
- Department of Medicine/Dermatology, University of Washington, Seattle, Washington
| |
Collapse
|
24
|
Fukano Y, Knowles NG, Usui ML, Underwood RA, Hauch KD, Marshall AJ, Ratner BD, Giachelli C, Carter WG, Fleckman P, Olerud JE. Characterization of an in vitro model for evaluating the interface between skin and percutaneous biomaterials. Wound Repair Regen 2007; 14:484-91. [PMID: 16939578 DOI: 10.1111/j.1743-6109.2006.00138.x] [Citation(s) in RCA: 45] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
Percutaneous devices play an essential role in medicine; however, they are often associated with a significant risk of infection. One approach to circumvent infection would be to heal the wound around the devices by promoting skin cell attachment. We used two in vitro assay models to evaluate cutaneous response to poly(2-hydoxyethyl methacrylate) (poly(HEMA)). One approach was to use a cell adhesion assay to test the effects of surface modification of poly(HEMA), and the second used an organ culture system of newborn foreskin biopsies implanted with porous poly(HEMA) rods (20 microm pores) to evaluate the skin/poly(HEMA) interface. Surface modification of poly(HEMA) using 1,1'-carbonyldiimidazole (CDI) enhanced keratinocyte, fibroblast, and endothelial cell adhesion. Keratinocytes in the organ culture model not only remained functionally and structurally viable as observed by immunohistochemistry and electron microscopy, but migrated into the pores of CDI-modified poly(HEMA) rods. No biointegration was seen in the non-CDI-modified poly(HEMA). Laminin 5 immunostaining was seen along the poly(HEMA)/skin interface in a pattern resembling the junctional epithelium of the tooth, the unique natural interface between the skin and tooth that serves as a barrier to bacteria. In vitro systematic evaluation of biomaterials for use in animal implant studies is both cost effective and time efficient.
Collapse
Affiliation(s)
- Yuko Fukano
- Department of Medicine (Dermatology), University of Washington, Seattle, Washington 98195-6524, USA.
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|