1
|
Dario V, Michelangelo-Santo G, Roberto B, Fabio F. Is All-on-four effective in case of partial mandibular resection? A 3D finite element study. JOURNAL OF STOMATOLOGY, ORAL AND MAXILLOFACIAL SURGERY 2023; 124:101463. [PMID: 37028491 DOI: 10.1016/j.jormas.2023.101463] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/06/2023] [Revised: 03/26/2023] [Accepted: 04/01/2023] [Indexed: 04/09/2023]
Abstract
INTRODUCTION The aim of the work is to analyze stress distribution on 3D Finite Element (FE) models at bone, implant, and framework level of different designs for fixed implant-supported prostheses in completely edentulous patients, comparing results on whole and partially resected mandibles. MATERIALS AND METHODS 3D anisotropic FE models of a whole and of a partially resected mandible were created using a TC scan of a cadaver's totally edentulous mandible. Two types of totally implant-supported rehabilitation were simulated, with four implants: parallel fixtures on whole mandible and on resected mandible, All-on-four-configured fixtures on whole mandible and on partially resected mandible. A superstructure comprising only metal components of a prosthetic framework were added, while stress distribution and its maximum values were analyzed at bone, implant, and superstructure level. RESULTS The results highlight that: (1) implant stresses are greater on the whole mandible than on the resected one; (2) framework and cancellous-bone stresses are comparable in all cases; (3) on the resected mandible, maximum stress levels at the cortical-bone/implant interface are higher than in whole-mandible rehabilitation. The opposite applies for maximum stresses on external cortical bone, measured radially with respect to the implant from the point of maximum stress at the interface. DISCUSSION On the resected mandible, All-on-four configuration proved biomechanically superior to parallel implants considering radial stresses on implants and cortical bone. Still, maximum stresses increase at the bone/implant interface. A design with four parallel implants minimizes the stress on a resected mandible while, on the whole mandible, the All-on-four rehabilitation proves superior at all levels (bone, implant, and framework).
Collapse
Affiliation(s)
- Vangi Dario
- Department of Industrial Engineering, Università degli Studi di Firenze, Via di Santa Marta 3, Firenze (FI) 50139, Italy
| | - Gulino Michelangelo-Santo
- Department of Industrial Engineering, Università degli Studi di Firenze, Via di Santa Marta 3, Firenze (FI) 50139, Italy.
| | - Branchi Roberto
- Department of Prosthodontics, Clinica Odontoiatrica Universitaria Ponte di Mezzo, Via del Ponte di Mezzo 46/48, Firenze (FI) 50127, Italy
| | - Ferretti Fabio
- Department of Prosthodontics, Clinica Odontoiatrica Universitaria Ponte di Mezzo, Via del Ponte di Mezzo 46/48, Firenze (FI) 50127, Italy
| |
Collapse
|
2
|
Cervino G, Romeo U, Lauritano F, Bramanti E, Fiorillo L, D'Amico C, Milone D, Laino L, Campolongo F, Rapisarda S, Cicciù M. Fem and Von Mises Analysis of OSSTEM ® Dental Implant Structural Components: Evaluation of Different Direction Dynamic Loads. Open Dent J 2018; 12:219-229. [PMID: 29682092 PMCID: PMC5885472 DOI: 10.2174/1874210601812010219] [Citation(s) in RCA: 67] [Impact Index Per Article: 11.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2017] [Revised: 02/12/2018] [Accepted: 02/28/2018] [Indexed: 11/22/2022] Open
Abstract
Purpose: The objective of this investigation is to study prosthodontics and internal components resistance to the masticatory stress and considering different force directions by using Finite Element Method analysis (FEM). The structural materials of the components are usually Titanium alloy grade 4 or 5 and thus, guarantee the integration of the fixture in the bone due to the osteointegration phenomena. Even if the long-term dental implant survival rate is easy to be obtained and confirmed by numerous researches, the related clinical success, due to the alteration of the mechanical and prosthodontics components is still controversial. Methods: By applying engineering systems of investigations like FEM and Von Mises analyses, it has been investigated how dental implant material was held against the masticatory strength during the dynamic masticatory cycles. A three-dimensional system involved fixture, abutment and the connection screws, which were created and analyzed. The elastic features of the materials used in the study were taken from recent literature data. Results: Data revealed a different response for both types of devices, although implant neck and dental abutment showed better results for all conditions of loading while the abutment screw represented aweak point of the system. Conclusion: The data of this virtual model showed all the features of different prosthetic retention systems under the masticatory load. Clinicians should find better prosthetic balance in order to better distribute the stress over the component and to guarantee patients’ clinical long-term results.
Collapse
Affiliation(s)
- Gabriele Cervino
- Department of Biomedical and Dental Sciences, Morphological and Functional Images, School of Dentistry, University of Messina, ME, Italy
| | - Umberto Romeo
- Department of Oral and Maxillo-facial Sciences, Pediatric Dentistry Unit, "Sapienza" University of Rome, Rome, Italy
| | - Floriana Lauritano
- Department of Biomedical and Dental Sciences, Morphological and Functional Images, School of Dentistry, University of Messina, ME, Italy
| | - Ennio Bramanti
- Department of Biomedical and Dental Sciences, Morphological and Functional Images, School of Dentistry, University of Messina, ME, Italy
| | - Luca Fiorillo
- Department of Biomedical and Dental Sciences, Morphological and Functional Images, School of Dentistry, University of Messina, ME, Italy
| | - Cesare D'Amico
- Department of Biomedical and Dental Sciences, Morphological and Functional Images, School of Dentistry, University of Messina, ME, Italy
| | - Dario Milone
- Departments of Engineering, University of Messina, Messina, Italy
| | - Luigi Laino
- Multidisciplinary Department of Medical-Surgical and Odontostomatological Specialties, University of Campania "Luigi Vanvitelli", Naples, NA, Italy
| | | | - Silvia Rapisarda
- Department of Biomedical and Dental Sciences, Morphological and Functional Images, School of Dentistry, University of Messina, ME, Italy
| | - Marco Cicciù
- Department of Biomedical and Dental Sciences, Morphological and Functional Images, School of Dentistry, University of Messina, ME, Italy
| |
Collapse
|
3
|
FEM Analysis of Mandibular Prosthetic Overdenture Supported by Dental Implants: Evaluation of Different Retention Methods. COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE 2015; 2015:943839. [PMID: 26798405 PMCID: PMC4700170 DOI: 10.1155/2015/943839] [Citation(s) in RCA: 59] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/05/2015] [Revised: 10/30/2015] [Accepted: 11/03/2015] [Indexed: 11/17/2022]
Abstract
Prosthetic rehabilitation of total edentulous jaws patients is today a common technique that clinicians approach in their daily practice. The use of dental implants for replacing missing teeth is going to be a safe technique and the implant-prosthetic materials give the possibility of having long-term clinical success. Aim of this work is to evaluate the mechanical features of three different prosthetic retention systems. By applying engineering systems of investigations like FEM and von Mises analyses, how the dental implant material holds out against the masticatory strength during the chewing cycles has been investigated. Three common dental implant overdenture retention systems have been investigated. The ball attachment system, the locator system, and the common dental abutment have been processed by Ansys Workbench 15.0 and underwent FEM and von Mises investigations. The elastic features of the materials used in the study have been taken from recent literature data. Results revealed different response for both types of device, although locator system showed better results for all conditions of loading. The data of this virtual model show all the features of different prosthetic retention systems under the masticatory load. Clinicians should find the better prosthetic solution related to the patients clinical condition in order to obtain long-term results.
Collapse
|
4
|
Hsiao WT, Lin LH, Chiang HJ, Ou KL, Cheng HY. Biomedical electrosurgery devices containing nanostructure for minimally invasive surgery: reduction of thermal injury and acceleration of wound healing for liver cancer. JOURNAL OF MATERIALS SCIENCE. MATERIALS IN MEDICINE 2015; 26:77. [PMID: 25631273 DOI: 10.1007/s10856-015-5416-4] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/22/2014] [Accepted: 11/01/2014] [Indexed: 06/04/2023]
Abstract
The aim of the present study was to investigate the thermal injury in the liver after a minimally invasive electrosurgery technique with a copper-doped diamond-like carbon (DLC-Cu) surface coating. To effectively utilize electrosurgery in a clinical caner setting, it is necessary to suppress the thermal injury to adjacent tissues. The surface morphologies of DLC-Cu thin films were characterized using scanning electron microscopy and transmission electron microscopy. Three-dimensional liver models were reconstructed using magnetic resonance imaging to simulate the electrosurgical procedure. Our results indicated that the temperature decreased significantly when minimally electrosurgery with nanostructured DLC-Cu thin films was used, and that it continued to decrease with increasing film thickness. In an animal model, thermography revealed that the surgical temperature was significantly lower in the minimally invasive electrosurgery with DLC-Cu thin film (DLC-Cu-SS) compared to untreated electrosurgery. In addition, DLC-Cu-SS created a relatively small thermal injury area and lateral thermal effect. These results indicated that the biomedical nanostructure coating reduced excessive thermal injury, and uniformly distributed temperature in the liver.
Collapse
Affiliation(s)
- Wen-Tien Hsiao
- Department of Diagnostic Radiology, Taipei Medical University Hospital, Taipei, 110, Taiwan
| | | | | | | | | |
Collapse
|
5
|
Influence of orthotropy on biomechanics of peri-implant bone in complete mandible model with full dentition. BIOMED RESEARCH INTERNATIONAL 2014; 2014:709398. [PMID: 25530968 PMCID: PMC4235237 DOI: 10.1155/2014/709398] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/29/2014] [Revised: 09/01/2014] [Accepted: 09/01/2014] [Indexed: 11/19/2022]
Abstract
Objective. The study was to investigate the impact of orthotropic material on the biomechanics of dental implant, based on a detailed mandible with high geometric and mechanical similarity. Materials and Methods. Multiple data sources were used to elaborate detailed biological structures and implant CAD models. In addition, an extended orthotropic material assignment methodology based on harmonic fields was used to handle the alveolar ridge region to generate compatible orthotropic fields. The influence of orthotropic material was compared with the commonly used isotropic model and simplified orthotropic model. Results. The simulation results showed that the values of stress and strain on the implant-bone interface almost increased in the orthotropic model compared to the isotropic case, especially for the cancellous bone. However, the local stress concentration was more obvious in the isotropic case compared to that in orthotropic case. The simple orthotropic model revealed irregular stress and strain distribution, compared to the isotropic model and the real orthotropic model. The influence of orthotropy was little on the implant, periodontal ligament, tooth enamel, and dentin. Conclusion. The orthotropic material has significant effect on stress and strain of implant-bone interface in the mandible, compared with the isotropic simulation. Real orthotropic mechanical properties of mandible should be emphasized in biomechanical studies of dental implants.
Collapse
|
6
|
Ferreira MB, Barão VA, Delben JA, Faverani LP, Hipólito AC, Assunção WG. Non-linear 3D finite element analysis of full-arch implant-supported fixed dentures. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2014; 38:306-14. [DOI: 10.1016/j.msec.2014.02.021] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/25/2013] [Revised: 01/14/2014] [Accepted: 02/16/2014] [Indexed: 12/01/2022]
|
7
|
Sarrafpour B, Swain M, Li Q, Zoellner H. Tooth eruption results from bone remodelling driven by bite forces sensed by soft tissue dental follicles: a finite element analysis. PLoS One 2013; 8:e58803. [PMID: 23554928 PMCID: PMC3598949 DOI: 10.1371/journal.pone.0058803] [Citation(s) in RCA: 46] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2012] [Accepted: 02/06/2013] [Indexed: 11/18/2022] Open
Abstract
Intermittent tongue, lip and cheek forces influence precise tooth position, so we here examine the possibility that tissue remodelling driven by functional bite-force-induced jaw-strain accounts for tooth eruption. Notably, although a separate true 'eruptive force' is widely assumed, there is little direct evidence for such a force. We constructed a three dimensional finite element model from axial computerized tomography of an 8 year old child mandible containing 12 erupted and 8 unerupted teeth. Tissues modelled included: cortical bone, cancellous bone, soft tissue dental follicle, periodontal ligament, enamel, dentine, pulp and articular cartilage. Strain and hydrostatic stress during incisive and unilateral molar bite force were modelled, with force applied via medial and lateral pterygoid, temporalis, masseter and digastric muscles. Strain was maximal in the soft tissue follicle as opposed to surrounding bone, consistent with follicle as an effective mechanosensor. Initial numerical analysis of dental follicle soft tissue overlying crowns and beneath the roots of unerupted teeth was of volume and hydrostatic stress. To numerically evaluate biological significance of differing hydrostatic stress levels normalized for variable finite element volume, 'biological response units' in Nmm were defined and calculated by multiplication of hydrostatic stress and volume for each finite element. Graphical representations revealed similar overall responses for individual teeth regardless if incisive or right molar bite force was studied. There was general compression in the soft tissues over crowns of most unerupted teeth, and general tension in the soft tissues beneath roots. Not conforming to this pattern were the unerupted second molars, which do not erupt at this developmental stage. Data support a new hypothesis for tooth eruption, in which the follicular soft tissues detect bite-force-induced bone-strain, and direct bone remodelling at the inner surface of the surrounding bony crypt, with the effect of enabling tooth eruption into the mouth.
Collapse
Affiliation(s)
- Babak Sarrafpour
- The Cellular and Molecular Pathology Research Unit, Department of Oral Pathology and Oral Medicine, Faculty of Dentistry, The University of Sydney, Westmead Hospital, Westmead, New South Wales, Australia.
| | | | | | | |
Collapse
|
8
|
3D finite element analysis of changes in stress levels and distributions for an osseointegrated implant after vertical bone loss. IMPLANT DENT 2012; 20:354-9. [PMID: 21811169 DOI: 10.1097/id.0b013e318226294b] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
PURPOSE The effect of stress levels and distributions around the internal nonsubmerged type implants after vertical bone resorption was investigated in this study. MATERIALS AND METHODS An HSII implant was placed in 4 cylindrical alveolar bone models with differing degrees of thread exposures. The load applied to each implant was von Mises stress and principal stress, 250 N in axial direction and 30 degrees lateral pressure. The difference in the load between the bone and the connective portion of the implant was obtained using ANSYS analysis. RESULTS Bone loss in the cervical area of the implant was more obvious under lateral pressure. When more threads were exposed, bone level decreased and the maximum load applied on the fixture increased. CONCLUSIONS It was concluded that higher bone level has a biomechanical advantage with respect to stress concentration.
Collapse
|
9
|
Limbert G, van Lierde C, Muraru OL, Walboomers XF, Frank M, Hansson S, Middleton J, Jaecques S. Trabecular bone strains around a dental implant and associated micromotions--a micro-CT-based three-dimensional finite element study. J Biomech 2010; 43:1251-61. [PMID: 20170921 DOI: 10.1016/j.jbiomech.2010.01.003] [Citation(s) in RCA: 37] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2007] [Revised: 12/27/2009] [Accepted: 01/29/2010] [Indexed: 10/19/2022]
Abstract
The first objective of this computational study was to assess the strain magnitude and distribution within the three-dimensional (3D) trabecular bone structure around an osseointegrated dental implant loaded axially. The second objective was to investigate the relative micromotions between the implant and the surrounding bone. The work hypothesis adopted was that these virtual measurements would be a useful indicator of bone adaptation (resorption, homeostasis, formation). In order to reach these objectives, a microCT-based finite element model of an oral implant implanted into a Berkshire pig mandible was developed along with a robust software methodology. The finite element mesh of the 3D trabecular bone architecture was generated from the segmentation of microCT scans. The implant was meshed independently from its CAD file obtained from the manufacturer. The meshes of the implant and the bone sample were registered together in an integrated software environment. A series of non-linear contact finite element (FE) analyses considering an axial load applied to the top of the implant in combination with three sets of mechanical properties for the trabecular bone tissue was devised. Complex strain distribution patterns are reported and discussed. It was found that considering the Young's modulus of the trabecular bone tissue to be 5, 10 and 15GPa resulted in maximum peri-implant bone microstrains of about 3000, 2100 and 1400. These results indicate that, for the three sets of mechanical properties considered, the magnitude of maximum strain lies within an homeostatic range known to be sufficient to maintain/form bone. The corresponding micro-motions of the implant with respect to the bone microstructure were shown to be sufficiently low to prevent fibrous tissue formation and to favour long-term osseointegration.
Collapse
Affiliation(s)
- Georges Limbert
- Biomaterials & Biomechanics Research Centre, School of Dentistry, Wales College of Medicine, Cardiff University, Cardiff CF14 4XY, UK.
| | | | | | | | | | | | | | | |
Collapse
|
10
|
Effect of varying the vertical dimension of connectors of cantilever cross-arch fixed dental prostheses in patients with severely reduced osseous support: a three-dimensional finite element analysis. J Prosthet Dent 2010; 103:91-100. [PMID: 20141813 DOI: 10.1016/s0022-3913(10)60012-1] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
STATEMENT OF PROBLEM Inadequate dimensioning of the connectors in a cantilever cross-arch fixed dental prosthesis (FDP) in perioprosthetic patients jeopardizes the prognosis of the restoration. PURPOSE The purpose of this study was to investigate the effect of increasing the vertical dimension (VD) on the maximum stress developed within the connectors during the static loading of a cross-arch FDP extended as a 1- and 2-unit cantilever. MATERIAL AND METHODS Six digital models were developed, derived from a 3-dimensional (3-D) initial model. In the initial model, the teeth were prepared for metal ceramic restorations and splinted with a cross-arch FDP, extended as a 1- or 2-unit cantilever. The VDs of the connectors proximal to the retaining abutment were 3, 4, or 5 mm. A 3-D finite element analysis (FEA) was performed. RESULTS The VD increase, from 3 to 4 mm and from 3 to 5 mm, of the connector distal to the retaining abutment, for each FDP, presented a maximum stress value decrease of approximately 25% and 48%, respectively. The similar VD increase of the connector mesial to the retaining abutment, for each FDP, resulted in relatively smaller stress changes. For the 2-unit cantilever restoration, the stress decreases were approximately 9% and 15%, respectively, whereas in the 1-unit cantilever restoration, the decrease was about 10% for the 4-mm connector. Further increase of the VD to 5 mm did not relieve the peak stress. The highest stress value was measured on the 3-mm connector distal to the retaining abutment in the 2-unit cantilever restoration. Despite the VD increase, the connectors proximal to the retaining abutment still developed the highest stress values of all the connectors for every model. CONCLUSIONS The connector with the highest risk of failure is the 3-mm connector distal to the retaining abutment of the 2-unit cantilever restoration. Increasing the vertical dimension is beneficial for the connector distal to the retaining abutment, while the resultant stress changes are not substantial for the connectors mesial to the retaining abutment. (J Prosthet Dent 2010;103:91-100).
Collapse
|
11
|
Lin D, Li Q, Li W, Swain M. Dental implant induced bone remodeling and associated algorithms. J Mech Behav Biomed Mater 2009; 2:410-32. [DOI: 10.1016/j.jmbbm.2008.11.007] [Citation(s) in RCA: 113] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2007] [Revised: 11/28/2008] [Accepted: 11/30/2008] [Indexed: 11/30/2022]
|
12
|
Mahmoud A, Cortes D, Abaza A, Ammar H, Hazey M, Ngan P, Crout R, Mukdadi O. Noninvasive assessment of human jawbone using ultrasonic guided waves. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2008; 55:1316-1327. [PMID: 18599419 DOI: 10.1109/tuffc.2008.794] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
The problem of detecting defects in jawbones is an important problem. Existing methods based on Xrays are invasive and constrain the achievable image quality. They also may carry known risks of cancer generation or may be limited in accurate diagnosis scope. This work is motivated by the lack of current imaging modalities to accurately predict the mechanical properties and defects in jawbone. Ultrasonic guided waves are sensitive to changes in microstructural properties and thus have been widely used for noninvasive material characterization. Using these waves may provide means for early diagnosis of marrow ischemic disorders via detecting focal osteoporotic marrow defect, chronic nonsuppurative osteomyelitis, and cavitations in the mandible (jawbone). Guided waves propagating along the mandibles may exhibit dispersion behavior that depends on material properties, geometry, and embedded cavities. In this work, we present the first study in the theoretical and experimental analysis of guided wave propagation in jawbone. Semianalytical, finite-element (SAFE) method is used to analyze dispersion behavior of guided waves propagating in human mandibles. The geometry of the cross section is obtained by segmenting the computed tomography (CT) images of the jawbone. The cross section of the mandible is divided in two regions representing the cortical and trabecular bones. Each region is modeled as a linear Hookean material. The material properties for both regions are adopted from the literature. The experimental setup for the guided waves experiment is described. The results from both numerical analysis and guided waves experiment exhibit variations in the group velocity of the first arrival signal and in the dispersion behavior of healthy and defected mandibles. These results shall provide a means to noninvasively characterize the jawbone and accurately assess the bone mechanical properties. Our study is not aimed at characterizing the bone density in human mandibles. Rather, it is aimed to assess bone mechanical properties and defects that cannot be diagnosed by X-ray or other imaging modalities. This work may pave the way to the development of inexpensive noninvasive devices to detect small defects in human mandibles.
Collapse
|
13
|
Al-Sukhun J, Ashammakhi N, Penttila H. Effects of Tissue-Engineered Articular Disc Implants on the Biomechanical Loading of the Human Temporomandibular Joint in a Three-Dimensional Finite Element Model. J Craniofac Surg 2007; 18:781-8; discussion 789-91. [PMID: 17667665 DOI: 10.1097/scs.0b013e31806900b2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
Abstract
The purpose of this study was to evaluate biomechanical loading of the temporomandibular joint when using a biodegradable laminate implant to replace the articular disc and to test the hypothesis that the use of the implant reduces stress distribution in the condyle, implant, and glenoid fossa. A finite element model of a female human mandible, including the temporomandibular joint, which had two standard endosseous implants inserted bilaterally in the premolar region, was constructed from computed tomography scan images using a commercially available finite element software. The disc, condyle, and glenoid fossa were arbitrarily divided into five regions: the anterior, posterior, medial, lateral, and central. The disc was then replaced with a poly-L/DL-lactide biodegradable laminate. The finite element model was then used to predict principal and Von Mises stresses. The use of poly-L/DL-lactide implant resulted in remarkable reduction in Von Mises stresses (approximately threefold) in the anterior, central, and medial regions of the mandibular condyle in comparison with slight to moderate stress reductions in the corresponding regions of the implant and glenoid fossa. The mandibular condyle also demonstrated the largest total displacement in all directions followed by the implant and glenoid fossa. The use of an alloplastic implant such as the bioresorbable, poly-L/DL-lactide laminate to replace the articular disc reduces loading of the mandibular condyle rather than the implant and glenoid fossa. These findings lead to support the hypothesis that the mandibular condyle more likely functions as a shock absorber than the disc. The use of bioresorbable laminate implants might prove an efficient technique to replace the articular disc and promote normal function of the temporomandibular joint.
Collapse
Affiliation(s)
- Jehad Al-Sukhun
- Euro-Oral Hammaslääkärikeskus, Fredrikinkatu 41A 9, Helsinki, Finland.
| | | | | |
Collapse
|