1
|
Albers S, Ono Y, Kirchner F, Fal MF, Kircher J. Midterm outcomes of autologous bridging of rotator cuff tears with an autologous tendon patch (TEAR patch). J Shoulder Elbow Surg 2024; 33:312-320. [PMID: 37482248 DOI: 10.1016/j.jse.2023.06.024] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/24/2023] [Revised: 06/16/2023] [Accepted: 06/21/2023] [Indexed: 07/25/2023]
Abstract
BACKGROUND Large and massive rotator cuff tears and tears after failed surgical repair are a challenging clinical problem with different treatment options. The purpose of the study was to evaluate the midterm outcomes after rotator cuff repair (RCR) with autologous hamstring tendon graft bridging (tissue-enhanced autologous rotator cuff repair [TEAR] patch) with the hypothesis that outcomes would be reasonable and complication rates would be low. METHODS This is a retrospective case series study of patients who underwent open RCR using a TEAR patch from June 2015 to March 2019. The exclusion criteria included evidence of cuff tear arthropathy, advanced fatty infiltration, moderate-to-severe arthropathy, and workers compensation board or litigation involved. Clinical outcome measures were Constant score; Disabilities of the Arm, Shoulder and Hand score; Simple Shoulder Test; Subjective Shoulder Value; range of motion (ROM); and manual muscle test for forward elevation, abduction, external and internal rotation, patient satisfaction, and willingness to perform the operation again. Radiographic outcome measures were magnetic resonance imaging, ultrasound, and radiographs: graft integrity and acromiohumeral distance (AHD). RESULTS A total of 44 patients were followed (89%) for ≥2 years (45 shoulders, mean age 60.3 years [48-76 years], mean follow-up 4.3 years [2-6 years]). All clinical outcome measures (Constant score, Disabilities of the Arm, Shoulder and Hand score, Simple Shoulder Test, Subjective Shoulder Value, ROM, and manual muscle test) demonstrated significant improvement except active external and internal rotation. At 2 years of follow-up, the mean patient satisfaction was high (12.2 of 15 points), and 33 of 38 patients (73.3%) would perform the operation again. A perfect graft integration was observed in 30 (66.7%), a small gap in 7 (15.6%), a retear in 3 (7%), and a complete failure of the tendon patch in 5 (11%) patients. Graft integrity was strongly correlated with the postoperative AHD (r = 0.599, P = .001) and the gain in AHD (r = 0.599, P = .001) but not with ROM or patient-reported outcome measures or patient satisfaction. Four patients required revision surgeries (3 due to deep infection and 1 for poor function and pain). CONCLUSIONS Midterm clinical and radiographic outcomes after RCR with graft bridging using a TEAR patch were reasonable. The procedure resulted in improved shoulder function and a high level of patient satisfaction. The revision rate is acceptable in view of the specific patient group and treatment alternatives. The described technique of the TEAR patch can be a valuable alternative to existing methods and a new autograft source for rotator cuff surgeries that need bridging of a tendon defect.
Collapse
Affiliation(s)
- Sebastian Albers
- Department of Shoulder and Elbow Surgery, ATOS Klinik Fleetinsel Hamburg, Hamburg, Germany.
| | - Yohei Ono
- Hokkaido Shoulder Clinic, Obihiro, Hokkaido, Japan
| | - Florian Kirchner
- Department of Shoulder and Elbow Surgery, ATOS Klinik Fleetinsel Hamburg, Hamburg, Germany
| | - Milad Farkhondeh Fal
- Department of Trauma and Orthopaedic Surgery, University Hospital Hamburg Eppendorf, Hamburg, Germany
| | - Jörn Kircher
- Department of Shoulder and Elbow Surgery, ATOS Klinik Fleetinsel Hamburg, Hamburg, Germany; Medical Faculty, Heinrich-Heine-University Düsseldorf, Düsseldorf, Germany
| |
Collapse
|
2
|
Liu S, Al-Danakh A, Wang H, Sun Y, Wang L. Advancements in scaffold for treating ligament injuries; in vitro evaluation. Biotechnol J 2024; 19:e2300251. [PMID: 37974555 DOI: 10.1002/biot.202300251] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2023] [Revised: 11/07/2023] [Accepted: 11/15/2023] [Indexed: 11/19/2023]
Abstract
Tendon/ligament (T/L) injuries are a worldwide health problem that affects millions of people annually. Due to the characteristics of tendons, the natural rehabilitation of their injuries is a very complex and lengthy process. Surgical treatment of a T/L injury frequently necessitates using autologous or allogeneic grafts or synthetic materials. Nonetheless, these alternatives have limitations in terms of mechanical properties and histocompatibility, and they do not permit the restoration of the original biological function of the tissue, which can negatively impact the patient's quality of life. It is crucial to find biological materials that possess the necessary properties for the successful surgical treatment of tissues and organs. In recent years, the in vitro regeneration of tissues and organs from stem cells has emerged as a promising approach for preparing autologous tissue and organs, and cell culture scaffolds play a critical role in this process. However, the biological traits and serviceability of different materials used for cell culture scaffolds vary significantly, which can impact the properties of the cultured tissues. Therefore, this review aims to analyze the differences in the biological properties and suitability of various materials based on scaffold characteristics such as cell compatibility, degradability, textile technologies, fiber arrangement, pore size, and porosity. This comprehensive analysis provides valuable insights to aid in the selection of appropriate scaffolds for in vitro tissue and organ culture.
Collapse
Affiliation(s)
- Shuang Liu
- Department of Urology, First Affiliated Hospital of Dalian Medical University, Dalian, China
| | - Abdullah Al-Danakh
- Department of Urology, First Affiliated Hospital of Dalian Medical University, Dalian, China
| | - Haowen Wang
- Department of Urology, First Affiliated Hospital of Dalian Medical University, Dalian, China
| | - Yuan Sun
- Liaoning Laboratory of Cancer Genomics and Department of Cell Biology, Dalian Medical University, Dalian, China
| | - Lina Wang
- Department of Urology, First Affiliated Hospital of Dalian Medical University, Dalian, China
| |
Collapse
|
3
|
Shah MM, Raibagkar S, Bansal S, Jain M, Ponugoti G. Patellar Tendon Rupture During Postoperative Physiotherapy for Crouch Gait: A Case Report. JBJS Case Connect 2023; 13:01709767-202312000-00047. [PMID: 38096336 DOI: 10.2106/jbjs.cc.23.00157] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2023]
Abstract
INTRODUCTION A 14-year-old adolescent girl with spastic diplegic cerebral palsy underwent bilateral distal femur extension osteotomy and patellar tendon plication. Two and a half months after surgery, during physiotherapy, she sustained mid-substance tear of the left patellar tendon. The girl was successfully managed with patellar tendon repair and augmentation with tensor fascia lata autograft. CONCLUSION Patellar tendon rupture during rehabilitative physiotherapy after patellar tendon plication surgery is rare. Postoperative protocols in patients with cerebral palsy are crucial and should progress gradually to improve knee range of motion. This report highlights that patellar tendon repair with fascia lata augmentation yields good outcome.
Collapse
|
4
|
Bonaldi L, Berardo A, Pirri C, Stecco C, Carniel EL, Fontanella CG. Mechanical Characterization of Human Fascia Lata: Uniaxial Tensile Tests from Fresh-Frozen Cadaver Samples and Constitutive Modelling. Bioengineering (Basel) 2023; 10:bioengineering10020226. [PMID: 36829719 PMCID: PMC9952725 DOI: 10.3390/bioengineering10020226] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2022] [Revised: 01/15/2023] [Accepted: 02/04/2023] [Indexed: 02/10/2023] Open
Abstract
Human Fascia Lata (FL) is a connective tissue with a multilayered organization also known as aponeurotic fascia. FL biomechanics is influenced by its composite structure formed by fibrous layers (usually two) separated by loose connective tissue. In each layer, most of the collagen fibers run parallel in a distinct direction (with an interlayer angle that usually ranges from 75-80°), mirroring the fascia's ability to adapt and withstand specific tensile loads. Although FL is a key structure in several musculoskeletal dysfunctions and in tissue engineering, literature still lacks the evidence that proves tissue anisotropy according to predominant collagen fiber directions. For this purpose, this work aims to analyze the biomechanical properties of ex-vivo FL (collected from fresh-frozen human donors) by performing uniaxial tensile tests in order to highlight any differences with respect to loading directions. The experimental outcomes showed a strong anisotropic behavior in accordance with principal collagen fibers directions, which characterize the composite structure. These findings have been implemented to propose a first constitutive model able to mimic the intra- and interlayer interactions. Both approaches could potentially support surgeons in daily practices (such as graft preparation and placement), engineers during in silico simulation, and physiotherapists during musculoskeletal rehabilitation, to customize a medical intervention based on each specific patient and clinical condition.
Collapse
Affiliation(s)
- Lorenza Bonaldi
- Department of Civil, Environmental and Architectural Engineering, University of Padova, 35131 Padova, Italy
| | - Alice Berardo
- Department of Civil, Environmental and Architectural Engineering, University of Padova, 35131 Padova, Italy
- Department of Biomedical Sciences, University of Padova, 35131 Padova, Italy
- Centre for Mechanics of Biological Materials, University of Padova, 35131 Padova, Italy
- Correspondence:
| | - Carmelo Pirri
- Department of Neuroscience, Institute of Human Anatomy, University of Padova, 35121 Padova, Italy
| | - Carla Stecco
- Centre for Mechanics of Biological Materials, University of Padova, 35131 Padova, Italy
- Department of Neuroscience, Institute of Human Anatomy, University of Padova, 35121 Padova, Italy
| | - Emanuele Luigi Carniel
- Centre for Mechanics of Biological Materials, University of Padova, 35131 Padova, Italy
- Department of Industrial Engineering, University of Padova, 35131 Padova, Italy
| | - Chiara Giulia Fontanella
- Centre for Mechanics of Biological Materials, University of Padova, 35131 Padova, Italy
- Department of Industrial Engineering, University of Padova, 35131 Padova, Italy
| |
Collapse
|
5
|
Xie Y, Zhang F, Akkus O, King MW. A collagen/PLA hybrid scaffold supports tendon-derived cell growth for tendon repair and regeneration. J Biomed Mater Res B Appl Biomater 2022; 110:2624-2635. [PMID: 35779243 PMCID: PMC9795886 DOI: 10.1002/jbm.b.35116] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2021] [Revised: 05/12/2022] [Accepted: 06/08/2022] [Indexed: 12/30/2022]
Abstract
A rotator cuff tendon tear is a common shoulder injury with a relatively high rate of recurrence after surgical repair. In order to reinforce the repair and reduce the risk of clinical complications, a patch scaffold is typically sutured over the tendon tear to provide post-surgical mechanical support. However, despite considerable research effort in this area, a patch scaffold that provides both superior initial mechanical properties and supports cell proliferation at the same time has not yet been achieved. In this study, we engineered a collagen/poly(lactic acid) (COL/PLA) hybrid yarn to leverage mechanical strength of PLA yarn and the bioactivity of collagen. The COL/PLA yarns were used to fabricate a tissue engineering scaffold using textile weaving technology. This hybrid scaffold had a tensile strength of 354.0 ± 36.0 N under dry conditions and 267.2 ± 15.9 N under wet conditions, which was satisfactory to maintain normal tendon function. By introducing COL yarns into the hybrid scaffold, the proliferation of tendon-derived cells was significantly improved on the scaffold. Cell coverage after 28-days of in vitro cell culture was noticeably higher on the COL yarns compared to the PLA yarns as a result of a larger number of cells and more spread cell morphology on collagen. Cells spread in multiple directions on COL yarns, which resembled a more natural cell attachment on extracellular matrix. On the contrary, the cells attached to the PLA filaments presented an elongated morphology along the fiber's axial direction. Combining the mechanical robustness of PLA and the biological activity of collagen, the woven COL/PLA hybrid scaffold has shown its potential to be a promising candidate for tendon repair applications.
Collapse
Affiliation(s)
- Yu Xie
- Wilson College of TextilesNorth Carolina State UniversityRaleighNorth CarolinaUSA
| | - Fan Zhang
- Wilson College of TextilesNorth Carolina State UniversityRaleighNorth CarolinaUSA
| | - Ozan Akkus
- Department of Mechanical and Aerospace EngineeringCase Western Reserve UniversityClevelandOhioUSA,Department of Biomedical EngineeringCase Western Reserve UniversityClevelandOhioUSA,Department of OrthopedicsCase Western Reserve UniversityClevelandOhioUSA
| | - Martin W. King
- Wilson College of TextilesNorth Carolina State UniversityRaleighNorth CarolinaUSA,College of TextilesDonghua UniversityShanghaiPeople's Republic of China
| |
Collapse
|
6
|
Cui J, Ning LJ, Yao X, Zhang Y, Zhang YJ, He SK, Zhang Z, Ding W, Luo JC, Qin TW. Influence of the integrity of tendinous membrane and fascicle on biomechanical characteristics of tendon-derived scaffolds. ACTA ACUST UNITED AC 2020; 16:015029. [PMID: 33065568 DOI: 10.1088/1748-605x/abc203] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
The biomechanical characteristics of tendon grafts is essential for tendon reconstructive surgery due to its great role in providing a good mechanical environment for tendon healing and regeneration. In our previous studies, the decellularized tendon slices (DTSs) and decellularized bovine tendon sheets (DBTSs) scaffolds were successfully developed. However, the influence of the integrity of tendinous membrane (endotenon and epitenon) and fascicle on biomechanical characteristics of these two scaffolds was not investigated. In this study, we assessed the integrity of tendinous membrane and fascicle of the tendon derived scaffolds and its effect on the biomechanical characteristics. The results of histological staining indicated that the DBTSs had complete endotenon and epitenon, while DTSs had no epitenon at all, only part of endotenon was remained. Furthermore, the DBTSs, and DTSs with thickness of 900 μm had complete fascicles, while DTSs with thickness less than 600 μm had almost no complete fascicles. The fibrous configuration of epitenon was well-preserved in the surface of the DBTSs but the surface ultrastructure of the DTSs was aligned collagen fibers based on scanning electron microscopy examination. The results of transmission electron microscopy showed that there was no significant difference between the DBTSs and DTSs. Mechanically, the DBTSs and DTSs with thickness of 900 μm showed similar ultimate tensile strength and stiffness to native tendon segments (NTSs). The strain at break and suture retention strength of the DBTSs showed much higher than that of the DTSs (p < 0.05). Additionally, the DBTSs showed higher ultimate load than the DTSs when these scaffolds were sutured with NTSs (p < 0.05) through the modified Kessler technique based on a uniaxial tensile test. This study demonstrated that DTSs may be used as a patch for reinforcing tendon repair, while DBTSs may be used as a bridge for reconstructing tendon defects.
Collapse
Affiliation(s)
- Jing Cui
- Laboratory of Stem Cell and Tissue Engineering, State Key Laboratory of Biotherapy, West China Hospital, Sichuan University, Chengdu 610041, People's Republic of China
| | | | | | | | | | | | | | | | | | | |
Collapse
|
7
|
Bridging Repair of Large Rotator Cuff Tears Using a Multilayer Decellularized Tendon Slices Graft in a Rabbit Model. Arthroscopy 2018; 34:2569-2578. [PMID: 30078689 DOI: 10.1016/j.arthro.2018.04.019] [Citation(s) in RCA: 27] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/20/2017] [Revised: 04/16/2018] [Accepted: 04/24/2018] [Indexed: 02/02/2023]
Abstract
PURPOSE The purpose of this study was to evaluate the efficacy of an extracellular matrix scaffold with multilayer decellularized tendon slices (MDTSs) for reconstructing large rotator cuff tears in a rabbit model. METHODS Large defects in the infraspinatus tendons were created bilaterally in 36 rabbits. The graft group underwent bridging repair of the defects with the MDTSs grafts from Achilles tendons of adult beagle dogs, and the control group underwent repair with the autologous excised tendon. Specimens underwent histologic observation, biomechanical testing, and microcomputed tomography analysis at 2, 4, and 8 weeks after surgery. RESULTS Histologic analysis confirmed that the MDTSs graft promoted cell ingrowth and tissue integration, and fibrocartilage and Sharpey fibers formed at the enthesis at 8 weeks. Accordingly, the MDTSs graft generated a histologic appearance similar to that of the autogenous tendon graft. Mechanical testing revealed a significant increase of the regenerated tendons in ultimate load and stiffness from 4 to 8 weeks postoperatively, which was similar to autologous tendon repair. Microcomputed tomography analysis demonstrated that the MDTSs graft promoted bone formation at the tendon-bone insertion, thus improving the mechanical properties of the repair tendon. CONCLUSIONS The MDTSs graft used to bridge large rotator cuff defects in a rabbit model promoted host cell ingrowth, enhanced the remodeling of regenerated tendon, and promoted fibrocartilage formation, thus improving the biomechanical properties of the repaired tendon. This study thereby provides fundamental information for rotator cuff regeneration with the MDTSs graft. CLINICAL RELEVANCE Rotator cuff regeneration using MDTSs grafts is a promising procedure for large rotator cuff tears.
Collapse
|
8
|
Kircher J, Schmidt F, Hawellek T, Hubert J, Hedtmann A, Püschel K, Hahn M, Niemeier A. Autologous bridging of rotator cuff tears with a hamstring tendon patch. A cadaver feasibility study and biomechanical testing. Clin Biomech (Bristol, Avon) 2018; 56:36-39. [PMID: 29787981 DOI: 10.1016/j.clinbiomech.2018.05.004] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/18/2018] [Revised: 04/16/2018] [Accepted: 05/04/2018] [Indexed: 02/07/2023]
Affiliation(s)
- Jörn Kircher
- ATOS Klinik Fleetinsel Hamburg, Department of Shoulder and Elbow Surgery, Admiralitätstrasse 3-4, 20459 Hamburg, Germany; Department of Orthopaedics, University Hospital, Medical Faculty, Heinrich-Heine-University Düsseldorf, Moorenstr. 5, 40255 Düsseldorf, Germany.
| | - Felix Schmidt
- Institute of Biomechanics, University Hospital Hamburg-Eppendorf, Lottestrasse 59, 22529 Hamburg, Germany
| | - Thelonius Hawellek
- Department of Orthopaedics, University Hospital Hamburg-Eppendorf, Eppendorfer Landstrasse 60, 20249 Hamburg, Germany
| | - Jan Hubert
- Department of Orthopaedics, University Hospital Hamburg-Eppendorf, Eppendorfer Landstrasse 60, 20249 Hamburg, Germany
| | - Achim Hedtmann
- ATOS Klinik Fleetinsel Hamburg, Department of Shoulder and Elbow Surgery, Admiralitätstrasse 3-4, 20459 Hamburg, Germany
| | - Klaus Püschel
- Department of Legal Medicine, University Hospital Hamburg-Eppendorf, Butenfeld 34, 22529 Hamburg, Germany
| | - Michael Hahn
- Institute of Biomechanics, University Hospital Hamburg-Eppendorf, Lottestrasse 59, 22529 Hamburg, Germany
| | - Andreas Niemeier
- Department of Orthopaedics, University Hospital Hamburg-Eppendorf, Eppendorfer Landstrasse 60, 20249 Hamburg, Germany
| |
Collapse
|
9
|
Milks RA, Kolmodin JD, Ricchetti ET, Iannotti JP, Derwin KA. Augmentation with a reinforced acellular fascia lata strip graft limits cyclic gapping of supraspinatus repairs in a human cadaveric model. J Shoulder Elbow Surg 2018; 27:1105-1111. [PMID: 29398399 DOI: 10.1016/j.jse.2017.12.016] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/28/2017] [Revised: 11/15/2017] [Accepted: 12/03/2017] [Indexed: 02/01/2023]
Abstract
BACKGROUND A reinforced biologic strip graft was designed to mechanically augment the repair of rotator cuff tears that are fully reparable by arthroscopic techniques yet have a likelihood of failure. This study assessed the extent to which augmentation of human supraspinatus repairs with a reinforced fascia strip can reduce gap formation during in vitro cyclic loading. METHODS The supraspinatus tendon was sharply released from the proximal humerus and repaired back to its insertion with anchors in 9 matched pairs of human cadaveric shoulders. One repair from each pair was also augmented with a reinforced fascia strip. All repairs were subjected to cyclic mechanical loading of 5 to 180 N for 1000 cycles. RESULTS All augmented and nonaugmented repair constructs completed 1000 cycles of loading. Augmentation with a reinforced fascia strip graft significantly decreased the amount of gap formation compared with nonaugmented repairs. The average gap formation of augmented repairs was 1.5 ± 0.7 mm after the first cycle vs. 3.0 ± 1.2 mm for nonaugmented repairs (P = .003) and 5.0 ± 1.5 mm after 1000 cycles of loading, which averaged 24% ± 21% less than the gap formation of nonaugmented repairs (7.0 ± 2.8 mm, P = .014). CONCLUSION Cadaveric human supraspinatus repairs augmented with a reinforced fascia strip have significantly less initial stroke elongation and gap formation than repairs without augmentation. Augmentation limited gap formation to the greatest extent early in the testing protocol. Human studies are necessary to confirm the appropriate indications and effectiveness of augmentation scaffolds for rotator cuff repair healing in the clinical setting.
Collapse
Affiliation(s)
- Ryan A Milks
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, OH, USA
| | - Joel D Kolmodin
- Department of Orthopaedic Surgery, Orthopaedic and Rheumatologic Institute, Cleveland Clinic, Cleveland, OH, USA
| | - Eric T Ricchetti
- Department of Orthopaedic Surgery, Orthopaedic and Rheumatologic Institute, Cleveland Clinic, Cleveland, OH, USA
| | - Joseph P Iannotti
- Department of Orthopaedic Surgery, Orthopaedic and Rheumatologic Institute, Cleveland Clinic, Cleveland, OH, USA
| | - Kathleen A Derwin
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, OH, USA.
| |
Collapse
|
10
|
Peixoto T, Pereira FAM, Silva PL, Guedes RM, Torres J, Lopes MA. Fibrous structures in augmentation for rotator cuff repair: an experimental comparison. Biomed Phys Eng Express 2018. [DOI: 10.1088/2057-1976/aac63e] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
|
11
|
Narayanan G, Nair LS, Laurencin CT. Regenerative Engineering of the Rotator Cuff of the Shoulder. ACS Biomater Sci Eng 2018; 4:751-786. [PMID: 33418763 DOI: 10.1021/acsbiomaterials.7b00631] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
Rotator cuff tears often heal poorly, leading to re-tears after repair. This is in part attributed to the low proliferative ability of the resident cells (tendon fibroblasts and tendon-stem cells) upon injury to the rotator cuff tissue and the low vascularity of the tendon insertion. In addition, surgical outcomes of current techniques used in clinical settings are often suboptimal, leading to the formation of neo-tissue with poor biomechanics and structural characteristics, which results in re-tears. This has prompted interest in a new approach, which we term as "Regenerative Engineering", for regenerating rotator cuff tendons. In the Regenerative Engineering paradigm, roles played by stem cells, scaffolds, growth factors/small molecules, the use of local physical forces, and morphogenesis interplayed with clinical surgery techniques may synchronously act, leading to synergistic effects and resulting in successful tissue regeneration. In this regard, various cell sources such as tendon fibroblasts and adult tissue-derived stem cells have been isolated, characterized, and investigated for regenerating rotator cuff tendons. Likewise, numerous scaffolds with varying architecture, geometry, and mechanical characteristics of biologic and synthetic origin have been developed. Furthermore, these scaffolds have been also fabricated with biochemical cues (growth factors and small molecules), facilitating tissue regeneration. In this Review, various strategies to regenerate rotator cuff tendons using stem cells, advanced materials, and factors in the setting of physical forces under the Regenerative Engineering paradigm are described.
Collapse
Affiliation(s)
- Ganesh Narayanan
- Institute for Regenerative Engineering, University of Connecticut Health Center, Farmington, Connecticut 06030, United States.,Raymond and Beverly Sackler Center for Biomedical, Biological, Physical and Engineering Sciences, University of Connecticut Health Center, Farmington, Connecticut 06030, United States.,Department of Orthopaedic Surgery, University of Connecticut Health Center, Farmington, Connecticut 06030, United States
| | - Lakshmi S Nair
- Institute for Regenerative Engineering, University of Connecticut Health Center, Farmington, Connecticut 06030, United States.,Raymond and Beverly Sackler Center for Biomedical, Biological, Physical and Engineering Sciences, University of Connecticut Health Center, Farmington, Connecticut 06030, United States.,Department of Orthopaedic Surgery, University of Connecticut Health Center, Farmington, Connecticut 06030, United States.,Department of Biomedical Engineering, University of Connecticut, Storrs, Connecticut 06269, United States.,Department of Materials Science and Engineering, University of Connecticut, Storrs, Connecticut 06269, United States
| | - Cato T Laurencin
- Institute for Regenerative Engineering, University of Connecticut Health Center, Farmington, Connecticut 06030, United States.,Raymond and Beverly Sackler Center for Biomedical, Biological, Physical and Engineering Sciences, University of Connecticut Health Center, Farmington, Connecticut 06030, United States.,Department of Orthopaedic Surgery, University of Connecticut Health Center, Farmington, Connecticut 06030, United States.,Department of Reconstructive Sciences, University of Connecticut Health Center, Farmington, Connecticut 06030, United States.,Department of Chemical and Biomolecular Engineering, University of Connecticut, Storrs, Connecticut 06269, United States.,Department of Biomedical Engineering, University of Connecticut, Storrs, Connecticut 06269, United States.,Department of Materials Science and Engineering, University of Connecticut, Storrs, Connecticut 06269, United States.,Connecticut Institute for Clinical and Translational Science, University of Connecticut Health Center, Farmington, Connecticut 06030, United States
| |
Collapse
|
12
|
An Update on Scaffold Devices for Rotator Cuff Repair. TECHNIQUES IN SHOULDER AND ELBOW SURGERY 2017. [DOI: 10.1097/bte.0000000000000122] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
|
13
|
Li C, Wang X, Zhao F, Wang F, Ting Z, Wang L. Modeling of braiding parameter impact on pore size and porosity in a tubular braiding fabric. E-POLYMERS 2017. [DOI: 10.1515/epoly-2016-0060] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
AbstractTubular braiding fabric is widely used in developing tissue-engineered scaffolds, and is especially suitable for connective tissues like ligaments and tendons. The pore size and porosity of braiding structure scaffolds not only highly affect cell adhesion and proliferation, but also influence the mechanical behavior of those scaffolds. It is important to develop braiding scaffolds with controllable pore size and distribution. The purpose of this work is to add insight to the mechanics of this passive pore structure control system. Thus, some constitutive equations were established to reveal the relationship between braiding technical parameters (including the number of spindles, braiding structure, cylindrical mandrel radius, and yarn diameter) and the pore size, the porosity of tubular braiding fabric by the mathematical modeling method. Through this model, pore size and the porosity of the tubular braiding scaffold can be precisely controlled by quantitatively adjusting braiding technical parameters. Furthermore, the reliability and accuracy of this model were verified by the experimental data.
Collapse
Affiliation(s)
- Chaojing Li
- 1Key Laboratory of Textile Science and Technology of Ministry of Education, Donghua University, 2999 North Renmin Road, Shanghai 201620, China
- 2College of Textiles, Donghua University, 2999 North Renmin Road, Shanghai 201620, China
| | - Xiaoming Wang
- 1Key Laboratory of Textile Science and Technology of Ministry of Education, Donghua University, 2999 North Renmin Road, Shanghai 201620, China
- 2College of Textiles, Donghua University, 2999 North Renmin Road, Shanghai 201620, China
| | - Fan Zhao
- 1Key Laboratory of Textile Science and Technology of Ministry of Education, Donghua University, 2999 North Renmin Road, Shanghai 201620, China
- 2College of Textiles, Donghua University, 2999 North Renmin Road, Shanghai 201620, China
| | - Fujun Wang
- 2College of Textiles, Donghua University, 2999 North Renmin Road, Shanghai 201620, China
| | - Zou Ting
- 1Key Laboratory of Textile Science and Technology of Ministry of Education, Donghua University, 2999 North Renmin Road, Shanghai 201620, China
- 2College of Textiles, Donghua University, 2999 North Renmin Road, Shanghai 201620, China
| | - Lu Wang
- 1Key Laboratory of Textile Science and Technology of Ministry of Education, Donghua University, 2999 North Renmin Road, Shanghai 201620, China
- 2College of Textiles, Donghua University, 2999 North Renmin Road, Shanghai 201620, China
| |
Collapse
|
14
|
Biologic and Synthetic Grafts in the Reconstruction of Large to Massive Rotator Cuff Tears. J Am Acad Orthop Surg 2016; 24:823-828. [PMID: 27768610 PMCID: PMC7322565 DOI: 10.5435/jaaos-d-15-00229] [Citation(s) in RCA: 37] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023] Open
Abstract
Rotator cuff injuries are common in both young and elderly patients. Despite improvements in instrumentation and surgical techniques, the failure rates following tendon reconstruction remain unacceptably high. To improve outcomes, graft patches have been developed to provide mechanical strength and to furnish a scaffold for biologic growth across the delicate tendon-bone junction. Although no patch effectively re-creates the structured, highly organized system of prenatal tendon development, augmenting rotator cuff repair may help restore native tendon-to-bone attachment while reproducing the mechanical and biologic properties of native tendon. An understanding of biologically and synthetically derived grafts, along with knowledge of the preliminary data available regarding their combined use with growth factors and stem cells, is needed to improve management and treatment outcomes. The current literature has not been consistent in showing patch augmentation to be beneficial over traditional repair, but novel scaffolding materials may help facilitate rotator cuff tendon repair that is histologically and biomechanically comparable to native tendon.
Collapse
|
15
|
Aibibu D, Hild M, Wöltje M, Cherif C. Textile cell-free scaffolds for in situ tissue engineering applications. JOURNAL OF MATERIALS SCIENCE. MATERIALS IN MEDICINE 2016; 27:63. [PMID: 26800694 PMCID: PMC4723636 DOI: 10.1007/s10856-015-5656-3] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/23/2015] [Accepted: 12/20/2015] [Indexed: 05/12/2023]
Abstract
In this article, the benefits offered by micro-fibrous scaffold architectures fabricated by textile manufacturing techniques are discussed: How can established and novel fiber-processing techniques be exploited in order to generate templates matching the demands of the target cell niche? The problems related to the development of biomaterial fibers (especially from nature-derived materials) ready for textile manufacturing are addressed. Attention is also paid on how biological cues may be incorporated into micro-fibrous scaffold architectures by hybrid manufacturing approaches (e.g. nanofiber or hydrogel functionalization). After a critical review of exemplary recent research works on cell-free fiber based scaffolds for in situ TE, including clinical studies, we conclude that in order to make use of the whole range of favors which may be provided by engineered fibrous scaffold systems, there are four main issues which need to be addressed: (1) Logical combination of manufacturing techniques and materials. (2) Biomaterial fiber development. (3) Adaption of textile manufacturing techniques to the demands of scaffolds for regenerative medicine. (4) Incorporation of biological cues (e.g. stem cell homing factors).
Collapse
Affiliation(s)
- Dilbar Aibibu
- Technische Universität Dresden, Fakultät Maschinenwesen, Institut für Textilmaschinen und Textile Hochleistungswerkstofftechnik, 01062, Dresden, Germany.
| | - Martin Hild
- Technische Universität Dresden, Fakultät Maschinenwesen, Institut für Textilmaschinen und Textile Hochleistungswerkstofftechnik, 01062, Dresden, Germany
| | - Michael Wöltje
- Technische Universität Dresden, Fakultät Maschinenwesen, Institut für Textilmaschinen und Textile Hochleistungswerkstofftechnik, 01062, Dresden, Germany
| | - Chokri Cherif
- Technische Universität Dresden, Fakultät Maschinenwesen, Institut für Textilmaschinen und Textile Hochleistungswerkstofftechnik, 01062, Dresden, Germany
| |
Collapse
|
16
|
Aurora A, Roe JL, Corona BT, Walters TJ. An acellular biologic scaffold does not regenerate appreciable de novo muscle tissue in rat models of volumetric muscle loss injury. Biomaterials 2015; 67:393-407. [PMID: 26256250 DOI: 10.1016/j.biomaterials.2015.07.040] [Citation(s) in RCA: 97] [Impact Index Per Article: 10.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2015] [Accepted: 07/22/2015] [Indexed: 12/21/2022]
Abstract
Extracellular matrix (ECM) derived scaffolds continue to be investigated for the treatment of volumetric muscle loss (VML) injuries. Clinically, ECM scaffolds have been used for lower extremity VML repair; in particular, MatriStem™, a porcine urinary bladder matrix (UBM), has shown improved functional outcomes and vascularization, but limited myogenesis. However, efficacy of the scaffold for the repair of traumatic muscle injuries has not been examined systematically. In this study, we demonstrate that the porcine UBM scaffold when used to repair a rodent gastrocnemius musculotendinous junction (MTJ) and tibialis anterior (TA) VML injury does not support muscle tissue regeneration. In the MTJ model, the scaffold was completely resorbed without tissue remodeling, suggesting that the scaffold may not be suitable for the clinical repair of muscle-tendon injuries. In the TA VML injury, the scaffold remodeled into a fibrotic tissue and showed functional improvement, but not due to muscle fiber regeneration. The inclusion of physical rehabilitation also did not improve functional response or tissue remodeling. We conclude that the porcine UBM scaffold when used to treat VML injuries may hasten the functional recovery through the mechanism of scaffold mediated functional fibrosis. Thus for appreciable muscle regeneration, repair strategies that incorporate myogenic cells, vasculogenic accelerant and a myoconductive scaffold need to be developed.
Collapse
Affiliation(s)
- Amit Aurora
- US Army Institute of Surgical Research, Extremity Trauma and Regenerative Medicine, 3698 Chambers Pass, Fort Sam Houston, TX 78234, USA
| | - Janet L Roe
- US Army Institute of Surgical Research, Extremity Trauma and Regenerative Medicine, 3698 Chambers Pass, Fort Sam Houston, TX 78234, USA
| | - Benjamin T Corona
- US Army Institute of Surgical Research, Extremity Trauma and Regenerative Medicine, 3698 Chambers Pass, Fort Sam Houston, TX 78234, USA
| | - Thomas J Walters
- US Army Institute of Surgical Research, Extremity Trauma and Regenerative Medicine, 3698 Chambers Pass, Fort Sam Houston, TX 78234, USA.
| |
Collapse
|
17
|
Helito CP, Bonadio MB, Angelini FJ, Tirico LEP, Pecora JR, Camanho GL, Demange MK. Reinforcement with fascia lata as an alternative in the repair of chronic quadriceps tendon injuries. Ups J Med Sci 2014; 119:354-6. [PMID: 25119626 PMCID: PMC4248077 DOI: 10.3109/03009734.2014.948695] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/19/2022] Open
Affiliation(s)
- Camilo Partezani Helito
- Institute of Orthopedics and Traumatology, Hospital das Clinicas, University of São Paulo, São Paulo, Brazil
| | - Marcelo Batista Bonadio
- Institute of Orthopedics and Traumatology, Hospital das Clinicas, University of São Paulo, São Paulo, Brazil
| | - Fabio Janson Angelini
- Institute of Orthopedics and Traumatology, Hospital das Clinicas, University of São Paulo, São Paulo, Brazil
| | | | - Jose Ricardo Pecora
- Institute of Orthopedics and Traumatology, Hospital das Clinicas, University of São Paulo, São Paulo, Brazil
| | - Gilberto Luis Camanho
- Institute of Orthopedics and Traumatology, Hospital das Clinicas, University of São Paulo, São Paulo, Brazil
| | - Marco Kawamura Demange
- Institute of Orthopedics and Traumatology, Hospital das Clinicas, University of São Paulo, São Paulo, Brazil
| |
Collapse
|
18
|
Sahoo S, DeLozier KR, Dumm RA, Rosen MJ, Derwin KA. Fiber-reinforced dermis graft for ventral hernia repair. J Mech Behav Biomed Mater 2014; 34:320-9. [DOI: 10.1016/j.jmbbm.2014.03.001] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2014] [Revised: 03/05/2014] [Accepted: 03/09/2014] [Indexed: 11/25/2022]
|
19
|
McCarron JA, Milks RA, Mesiha M, Aurora A, Walker E, Iannotti JP, Derwin KA. Reinforced fascia patch limits cyclic gapping of rotator cuff repairs in a human cadaveric model. J Shoulder Elbow Surg 2012; 21:1680-6. [PMID: 22361715 DOI: 10.1016/j.jse.2011.11.039] [Citation(s) in RCA: 36] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/16/2011] [Revised: 11/19/2011] [Accepted: 11/28/2011] [Indexed: 02/01/2023]
Abstract
BACKGROUND Scaffolds continue to be developed and used for rotator cuff repair augmentation, but clinical or biomechanical data to inform their use are limited. We have developed a reinforced fascia lata patch with mechanical properties to meet the needs of musculoskeletal applications. The objective of this study was to assess the extent to which augmentation of a primary human rotator cuff repair with the reinforced fascia patch can reduce gap formation during in vitro cyclic loading. MATERIALS AND METHODS Nine paired human cadaveric shoulders were used to investigate the cyclic gap formation and failure properties of augmented and non-augmented rotator cuff repairs with loading of 5 to 180 N for 1000 cycles. RESULTS Augmentation significantly decreased the amount of gap formation at cycles 1, 10, 100, and 1000 compared with non-augmented repairs (P < .01). The mean gap formation of the augmented repairs was 1.8 mm after the first cycle of pull (vs 3.6 mm for non-augmented repairs) and remained less than 5 mm after 1000 cycles of loading (4.7 mm for augmented repairs vs 7.3 mm for non-augmented repairs). Furthermore, all augmented repairs were able to complete the 1000-cycle loading protocol, whereas 3 of 9 non-augmented repairs failed before completing 1000 loading cycles. CONCLUSIONS This study supports further investigation of reinforced fascia patches to provide mechanical augmentation, minimize tendon retraction, and possibly reduce the incidence of rotator cuff repair failure. Future investigation in animal and human studies will be necessary to fully define the efficacy of the reinforced fascia device in a biologic healing environment.
Collapse
Affiliation(s)
- Jesse A McCarron
- Orthopaedic Surgery Section, Department of Veterans Affairs Medical Center, Portland, OR, USA
| | | | | | | | | | | | | |
Collapse
|
20
|
Abstract
BACKGROUND Scaffold devices are used to augment rotator cuff repairs in humans. While the strength of a novel poly-L-lactic acid-reinforced (human) fascia patch has been documented, it is unclear whether such patches will enhance the strength or likelihood of healing of rotator cuff repairs. QUESTIONS/PURPOSES In a canine shoulder model, we asked: Do tendon repairs augmented with a reinforced fascia patch have (1) increased biomechanical properties at Time 0 and (2) less tendon retraction and increased cross-sectional area and biomechanical properties after 12 weeks of healing compared to repairs without augmentation? (3) Do the biomechanical properties of tendon repairs reach normal values by 12 weeks of healing? And (4) is the host response associated with use of the reinforced fascia patch biocompatible? METHODS Eleven dogs underwent bilateral shoulder surgery with partial release and acute repair of the infraspinatus tendon, one shoulder with augmentation and one without augmentation. Repair retraction, cross-sectional area, biomechanical properties, and biocompatibility were assessed at 12 weeks. RESULTS At Time 0, the mean ± SD ultimate load of augmented repairs was 296 ± 130 N (46% ± 25%) more than nonaugmented repairs, with no difference in stiffness between groups. At 12 weeks, the ultimate load of augmented repairs averaged 192 ± 213 N (15% ± 16%) less than nonaugmented repairs, with no difference in stiffness between groups. At the tendon repair site at 12 weeks, the fascia patch showed a biocompatible host tissue response. CONCLUSIONS The biomechanical properties of repairs augmented with a reinforced fascia patch demonstrated greater ultimate load at Time 0 than nonaugmented repairs but remained essentially unchanged after 12 weeks of healing, despite improvements in the ultimate load of nonaugmented controls in the same time frame.
Collapse
|
21
|
Rotator cuff: biology and current arthroscopic techniques. Knee Surg Sports Traumatol Arthrosc 2012; 20:1003-11. [PMID: 22270674 DOI: 10.1007/s00167-012-1901-1] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/01/2011] [Accepted: 01/10/2012] [Indexed: 12/19/2022]
Abstract
UNLABELLED The present article summarizes current trends in arthroscopic rotator cuff repairs focusing on the used repair technique, potential influencing factors on the results, and long-term outcome after reconstruction of the rotator cuff. Moreover, different treatment options for the treatment for irreparable rotator cuff ruptures were described, and the results of additional augmentation of the repairs with platelet-rich plasma were critically analyzed. Based on the current literature, double-row repairs did not achieve superior clinical results compared to single-row repairs neither in the clinical results nor in the re-rupture rate. Multiple factors such as age, fatty infiltration, and initial rupture size might influence the results. If the rupture is not repairable, various options were described including cuff debridement, partial repair, tuberoplasty, or tendon transfers. The additional augmentation with platelet-rich plasma did not reveal any significant differences in the healing rate compared to conventional rotator cuff repairs. LEVEL OF EVIDENCE IV.
Collapse
|
22
|
Ricchetti ET, Aurora A, Iannotti JP, Derwin KA. Scaffold devices for rotator cuff repair. J Shoulder Elbow Surg 2012; 21:251-65. [PMID: 22244069 DOI: 10.1016/j.jse.2011.10.003] [Citation(s) in RCA: 146] [Impact Index Per Article: 12.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/09/2011] [Accepted: 10/19/2011] [Indexed: 02/01/2023]
Abstract
Rotator cuff tears affect 40% or more of those aged older than 60 years, and repair failure rates of 20% to 70% remain a significant clinical challenge. Hence, there is a need for repair strategies that can augment the repair by mechanically reinforcing it, while at the same time biologically enhancing the intrinsic healing potential of the tendon. Tissue engineering strategies to improve rotator cuff repair healing include the use of scaffolds, growth factors, and cell seeding, or a combination of these approaches. Currently, scaffolds derived from mammalian extracellular matrix, synthetic polymers, and a combination thereof, have been cleared by the U.S. Food and Drug Administration and are marketed as medical devices for rotator cuff repair in humans. Despite the growing clinical use of scaffold devices for rotator cuff repair, there are numerous questions related to their indication, surgical application, safety, mechanism of action, and efficacy that remain to be clarified or addressed. This article reviews the current basic science and clinical understanding of commercially available synthetic and extracellular matrix scaffolds for rotator cuff repair. Our review will emphasize the host response and scaffold remodeling, mechanical and suture-retention properties, and preclinical and clinical studies on the use of these scaffolds for rotator cuff repair. We will discuss the implications of these data on the future directions for use of these scaffolds in tendon repair procedures.
Collapse
Affiliation(s)
- Eric T Ricchetti
- Department of Orthopedic Surgery, Orthopedic and Rheumatologic Institute, Cleveland Clinic, Cleveland, OH, USA
| | | | | | | |
Collapse
|
23
|
Chin L, Calabro A, Walker E, Derwin KA. Mechanical properties of tyramine substituted-hyaluronan enriched fascia extracellular matrix. J Biomed Mater Res A 2012; 100:786-93. [PMID: 22238019 DOI: 10.1002/jbm.a.34025] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2011] [Revised: 10/25/2011] [Accepted: 11/07/2011] [Indexed: 12/12/2022]
Abstract
Naturally occurring biomaterial scaffolds derived from extracellular matrix (ECM) have been the topic of recent investigation in the context of rotator cuff tendon repair. We previously reported a method to treat fascia ECM with high molecular weight tyramine substituted-hyaluronan (TS-HA) for use as a tendon augmentation scaffold. The presence of crosslinked TS-HA in fascia was associated with an increased macrophage and giant cell response compared to water-treated controls after implantation in a rat abdominal wall model. The objective of this study was to determine the extent to which TS-HA treatment was associated with mechanical property changes of fascia after implantation in the rat model. Fascia samples in all groups demonstrated time-dependent decreases in mechanical properties. TS-HA-treated fascia with crosslinking exhibited a lower toe modulus, a trend toward lower toe stiffness, and a higher transition strain than water-treated controls not only after implantation, but also at time zero. TS-HA treatment, with or without crosslinking, had no significant effect on time-zero or post-implantation load relaxation ratio, load relaxation rate, linear-region stiffness, or linear-region modulus. Our findings demonstrated that the particular TS-HA treatment employed in this study decreased the low-load elastic mechanical properties of fascia ECM, in keeping with the heightened macrophage and giant cell host response seen previously. This work provides a starting point and guidance for investigating alternative HA treatment strategies.
Collapse
Affiliation(s)
- Likang Chin
- Department of Biomedical Engineering, Lerner Research Institute and Orthopedic Research Center, Cleveland Clinic, Cleveland, Ohio, USA
| | | | | | | |
Collapse
|