1
|
Fujii Y, Nakatani T, Ousaka D, Oozawa S, Sasai Y, Kasahara S. Development of Antimicrobial Surfaces Using Diamond-like Carbon or Diamond-like Carbon-Based Coatings. Int J Mol Sci 2024; 25:8593. [PMID: 39201280 PMCID: PMC11354288 DOI: 10.3390/ijms25168593] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2024] [Revised: 07/20/2024] [Accepted: 07/26/2024] [Indexed: 09/02/2024] Open
Abstract
The medical device market is a high-growth sector expected to sustain an annual growth rate of over 5%, even in developed countries. Daily, numerous patients have medical devices implanted or inserted within their bodies. While medical devices have significantly improved patient outcomes, as foreign objects, their wider use can lead to an increase in device-related infections, thereby imposing a burden on healthcare systems. Multiple materials with significant societal impact have evolved over time: the 19th century was the age of iron, the 20th century was dominated by silicon, and the 21st century is often referred to as the era of carbon. In particular, the development of nanocarbon materials and their potential applications in medicine are being explored, although the scope of these applications remains limited. Technological innovations in carbon materials are remarkable, and their application in medicine is expected to advance greatly. For example, diamond-like carbon (DLC) has garnered considerable attention for the development of antimicrobial surfaces. Both DLC itself and its derivatives have been reported to exhibit anti-microbial properties. This review discusses the current state of DLC-based antimicrobial surface development.
Collapse
Affiliation(s)
- Yasuhiro Fujii
- Center for Innovative Clinical Medicine, Okayama University Hospital, Okayama University, Okayama 700-8558, Japan
| | - Tatsuyuki Nakatani
- Institute of Frontier Science and Technology, Okayama University of Science, Okayama 700-0005, Japan;
| | - Daiki Ousaka
- Department of Pharmacology, Faculty of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University, Okayama 700-8558, Japan;
| | - Susumu Oozawa
- Division of Medical Safety Management, Safety Management Facility, Okayama University Hospital, Okayama University, Okayama 700-8558, Japan;
| | - Yasushi Sasai
- Department of Pharmacy, Gifu University of Medical Science, Kani 509-0293, Japan;
| | - Shingo Kasahara
- Department of Cardiovascular Surgery, Faculty of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University, Okayama 700-8558, Japan;
| |
Collapse
|
2
|
Duan X, Yang Y, Zhang T, Zhu B, Wei G, Li H. Research progress of metal biomaterials with potential applications as cardiovascular stents and their surface treatment methods to improve biocompatibility. Heliyon 2024; 10:e25515. [PMID: 38375258 PMCID: PMC10875388 DOI: 10.1016/j.heliyon.2024.e25515] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2023] [Revised: 01/23/2024] [Accepted: 01/29/2024] [Indexed: 02/21/2024] Open
Abstract
Facing the growing issue of cardiovascular diseases, metallic materials with higher tensile strength and fatigue resistance play an important role in treating diseases. This review lists the advantages and drawbacks of commonly used medical metallic materials for vascular stents. To avoid post-procedural threats such as thrombosis and in-stent restenosis, surface treatments, and coating methods have been used to further improve the biocompatibility of these materials. Surface treatments including laser, plasma treatment, polishing, oxidization, and fluorination can improve biocompatibility by modifying the surface charges, surface morphology, and surface properties of the material. Coating methods based on polymer coatings, carbon-based coatings, and drug-functional coatings can regulate the surface properties, and also serve as an effective barrier to the interaction of metallic biomaterial surfaces with biomolecules, which can be used to improve corrosion resistance and stability, as well as improve their biocompatibility. Biocompatibility serves as the most fundamental property of cardiovascular stents, and maintaining the excellent and stable biocompatibility of cardiovascular stent surfaces is a current research bottleneck. Few reviews have been published on metallic biomaterials as cardiovascular stents and their surface treatments. For the purpose of advancing research on cardiovascular stents, common metal biomaterials, surface treatment methods, and coating methods to improve biocompatibility and comprehensive properties of the materials are described in this review. Finally, we suggest future directions for stent development, including continuously improving the durability and stability of permanent stents, accelerating the development of biodegradable stents, and strengthening feedback to improve the safety and reliability of cardiovascular stents.
Collapse
Affiliation(s)
- Xuejia Duan
- College of Materials and Chemistry, China Jiliang University, Hangzhou, Zhejiang 310018, China
- Division of Chemistry and Analytical Science, National Institute of Metrology, Beijing, China
| | - Yumeng Yang
- College of Materials and Chemistry, China Jiliang University, Hangzhou, Zhejiang 310018, China
| | - Tianji Zhang
- Division of Chemistry and Analytical Science, National Institute of Metrology, Beijing, China
- Key Laboratory of Chemical Metrology and Applications on Nutrition and Health for State Market Regulation, China
| | - Benfeng Zhu
- College of Materials and Chemistry, China Jiliang University, Hangzhou, Zhejiang 310018, China
| | - Guoying Wei
- College of Materials and Chemistry, China Jiliang University, Hangzhou, Zhejiang 310018, China
| | - Hongmei Li
- Division of Chemistry and Analytical Science, National Institute of Metrology, Beijing, China
- Key Laboratory of Chemical Metrology and Applications on Nutrition and Health for State Market Regulation, China
| |
Collapse
|
3
|
Borges GA, Costa RC, Nagay BE, Sacramento CM, Ruiz KGS, Solano de Almeida L, Rossino LS, Fortulan CA, Rangel EC, Barão VAR, Mesquita MF. Targeting Biomechanical Endurance of Dental-Implant Abutments Using a Diamond-Like Carbon Coating. ACS APPLIED BIO MATERIALS 2023; 6:5630-5643. [PMID: 38052058 DOI: 10.1021/acsabm.3c00802] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/07/2023]
Abstract
Abutment components (i.e., fixtures associated with oral implants) are essentially made of titanium (Ti), which is continuously exposed to the hash oral environment, resulting in scratching. Thus, such components need to be protected, and surface treatments are viable methods for overcoming long-term damage. Diamond-like carbon (DLC), an excellent protective material, is an alternative surface-treatment material for Ti abutments. Here, we demonstrate that a silicon interlayer for DLC film growth and the pulsed-direct current plasma-enhanced chemical vapor deposition (DC-PECVD) method enables the deposition of an enhanced protective DLC film. As a result, the DLC film demonstrated a smooth topography with a compact surface. Furthermore, the DLC film enhanced the mechanical (load-displacement, hardness, and elastic modulus) and tribological properties of Ti as well as increased its corrosion resistance (16-fold), which surpassed that of a bare Ti substrate. The biofilm formed (Streptococcus sanguinis) after 24 h exhibited an equal bacterial load (∼7 Log colony-forming units) for both the groups (Ti and DLC). In addition, the DLC film exhibited good cytocompatibility, owing to its noncytotoxicity toward human gingival fibroblast cells. Therefore, DLC deposition via DC-PECVD can be considered to be a promising protective and cytocompatible alternative for developing implant abutments with enhanced mechanical, tribological, and electrochemical properties.
Collapse
Affiliation(s)
- Guilherme Almeida Borges
- University of Campinas (UNICAMP), Piracicaba Dental School, Department of Prosthodontics and Periodontics, Avenida Limeira, 901, Piracicaba, São Paulo 13414-903, Brazil
| | - Raphael Cavalcante Costa
- University of Campinas (UNICAMP), Piracicaba Dental School, Department of Prosthodontics and Periodontics, Avenida Limeira, 901, Piracicaba, São Paulo 13414-903, Brazil
| | - Bruna Egumi Nagay
- University of Campinas (UNICAMP), Piracicaba Dental School, Department of Prosthodontics and Periodontics, Avenida Limeira, 901, Piracicaba, São Paulo 13414-903, Brazil
| | - Catharina Marques Sacramento
- University of Campinas (UNICAMP), Piracicaba Dental School, Department of Prosthodontics and Periodontics, Avenida Limeira, 901, Piracicaba, São Paulo 13414-903, Brazil
| | - Karina Gonzales Silverio Ruiz
- University of Campinas (UNICAMP), Piracicaba Dental School, Department of Prosthodontics and Periodontics, Avenida Limeira, 901, Piracicaba, São Paulo 13414-903, Brazil
| | - Larissa Solano de Almeida
- Federal University of São Carlos (UFSCar) - Campus Sorocaba, Postgraduate Program in Materials Science, Rodovia João Leme dos Santos, Km 110, Sorocaba, São Paulo 18052-780, Brazil
| | - Luciana Sgarbi Rossino
- Federal University of São Carlos (UFSCar) - Campus Sorocaba, Postgraduate Program in Materials Science, Rodovia João Leme dos Santos, Km 110, Sorocaba, São Paulo 18052-780, Brazil
- State Center of Technological Education "Paula Souza" (CEETEPS), Sorocaba Technology College - Campus Sorocaba (Fatec Sorocaba), Avenida Engenheiro Carlos Reinaldo Mendes, 2015, Sorocaba, São Paulo 18013-280, Brazil
| | - Carlos Alberto Fortulan
- University of São Paulo (USP), Department of Mechanical Engineering, Trabalhador São Carlense 400, São Carlos, São Paulo 13566-590, Brazil
| | - Elidiane Cipriano Rangel
- São Paulo State University (UNESP), Institute of Science and Technology, Laboratory of Technological Plasmas, Avenida Três de Março, 51, Sorocaba, São Paulo 18087-180, Brazil
| | - Valentim A R Barão
- University of Campinas (UNICAMP), Piracicaba Dental School, Department of Prosthodontics and Periodontics, Avenida Limeira, 901, Piracicaba, São Paulo 13414-903, Brazil
| | - Marcelo Ferraz Mesquita
- University of Campinas (UNICAMP), Piracicaba Dental School, Department of Prosthodontics and Periodontics, Avenida Limeira, 901, Piracicaba, São Paulo 13414-903, Brazil
| |
Collapse
|
4
|
Plasma Modification of Carbon Coating Produced by RF CVD on Oxidized NiTi Shape Memory Alloy under Glow-Discharge Conditions. MATERIALS 2021; 14:ma14174842. [PMID: 34500931 PMCID: PMC8432699 DOI: 10.3390/ma14174842] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/29/2021] [Revised: 08/19/2021] [Accepted: 08/23/2021] [Indexed: 11/16/2022]
Abstract
Our previous work has shown that for cardiac applications, combining low-temperature plasma oxidation with an amorphous carbon coating (a-C:N:H type) constitutes a prospective solution. In this study, a short-term modification by low-temperature oxygen plasma is proposed as an example and a method for shaping the topography and surface energy of the outer amorphous carbon coating, produced via the Radio-Frequency Chemical Vapour Deposition (RFCVD) method on NiTi alloy oxidized under glow-discharge conditions. This treatment alters the chemical composition of the outer zone of the surface layer. A slight increase is also noted in the surface roughness at the nanoscale. The contact angles were shown to increase by about 20% for water and 30% for diiodomethane, while the surface free energy decreased by ca. 11%. The obtained results indicate that even short-term contact with low-temperature plasma can shape the surface properties of the carbon coating, an outcome which shows potential in terms of its use in medical applications.
Collapse
|
5
|
Overview on the Antimicrobial Activity and Biocompatibility of Sputtered Carbon-Based Coatings. Processes (Basel) 2021. [DOI: 10.3390/pr9081428] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022] Open
Abstract
Due to their outstanding properties, carbon-based structures have received much attention from the scientific community. Their applications are diverse and include use in coatings on self-lubricating systems for anti-wear situations, thin films deposited on prosthetic elements, catalysis structures, or water remediation devices. From these applications, the ones that require the most careful testing and improvement are biomedical applications. The biocompatibility and antibacterial issues of medical devices remain a concern, as several prostheses still fail after several years of implantation and biofilm formation remains a real risk to the success of a device. Sputtered deposition prevents the introduction of hazardous chemical elements during the preparation of coatings, and this technique is environmentally friendly. In addition, the mechanical properties of C-based coatings are remarkable. In this paper, the latest advances in sputtering methods and biocompatibility and antibacterial action for diamond-based carbon (DLC)-based coatings are reviewed and the greater outlook is then discussed.
Collapse
|
6
|
Liu J, Liu J, Attarilar S, Wang C, Tamaddon M, Yang C, Xie K, Yao J, Wang L, Liu C, Tang Y. Nano-Modified Titanium Implant Materials: A Way Toward Improved Antibacterial Properties. Front Bioeng Biotechnol 2020; 8:576969. [PMID: 33330415 PMCID: PMC7719827 DOI: 10.3389/fbioe.2020.576969] [Citation(s) in RCA: 36] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2020] [Accepted: 10/22/2020] [Indexed: 01/01/2023] Open
Abstract
Titanium and its alloys have superb biocompatibility, low elastic modulus, and favorable corrosion resistance. These exceptional properties lead to its wide use as a medical implant material. Titanium itself does not have antibacterial properties, so bacteria can gather and adhere to its surface resulting in infection issues. The infection is among the main reasons for implant failure in orthopedic surgeries. Nano-modification, as one of the good options, has the potential to induce different degrees of antibacterial effect on the surface of implant materials. At the same time, the nano-modification procedure and the produced nanostructures should not adversely affect the osteogenic activity, and it should simultaneously lead to favorable antibacterial properties on the surface of the implant. This article scrutinizes and deals with the surface nano-modification of titanium implant materials from three aspects: nanostructures formation procedures, nanomaterials loading, and nano-morphology. In this regard, the research progress on the antibacterial properties of various surface nano-modification of titanium implant materials and the related procedures are introduced, and the new trends will be discussed in order to improve the related materials and methods.
Collapse
Affiliation(s)
- Jianqiao Liu
- Department of Orthopaedics, Affiliated Hospital of Youjiang Medical University for Nationalities, Baise, China
- Youjiang Medical University for Nationalities, Baise, China
| | - Jia Liu
- Department of Orthopaedics, Affiliated Hospital of Youjiang Medical University for Nationalities, Baise, China
| | - Shokouh Attarilar
- Department of Pediatric Orthopaedics, Xin Hua Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, China
- State Key Laboratory of Metal Matrix Composites, School of Materials Science and Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Chong Wang
- College of Mechanical Engineering, Dongguan University of Technology, Dongguan, China
| | - Maryam Tamaddon
- Institute of Orthopaedic and Musculoskeletal Science, Division of Surgery & Orthopaedic Science, University College London, The Royal National National Orthopaedic Hospital, Stanmore, United Kingdom
| | - Chengliang Yang
- Department of Orthopaedics, Affiliated Hospital of Youjiang Medical University for Nationalities, Baise, China
| | - Kegong Xie
- Department of Orthopaedics, Affiliated Hospital of Youjiang Medical University for Nationalities, Baise, China
| | - Jinguang Yao
- Youjiang Medical University for Nationalities, Baise, China
| | - Liqiang Wang
- State Key Laboratory of Metal Matrix Composites, School of Materials Science and Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Chaozong Liu
- Institute of Orthopaedic and Musculoskeletal Science, Division of Surgery & Orthopaedic Science, University College London, The Royal National National Orthopaedic Hospital, Stanmore, United Kingdom
| | - Yujin Tang
- Department of Orthopaedics, Affiliated Hospital of Youjiang Medical University for Nationalities, Baise, China
| |
Collapse
|
7
|
Yang J, Li H, Wang Z, Yu L, Liu Q, Niu X, Xu T, Wang Z. Dihydroartemisinin inhibits multiplication of Brucella suis vaccine strain 2 in murine microglia BV2 cells via stimulation of caspase‑dependent apoptosis. Mol Med Rep 2019; 20:4067-4072. [PMID: 31545433 PMCID: PMC6797990 DOI: 10.3892/mmr.2019.10672] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2018] [Accepted: 07/26/2019] [Indexed: 02/02/2023] Open
Abstract
Brucellosis, caused by a facultative intracellular parasite Brucella species, is the most common bacterial zoonotic infection worldwide. Brucella can survive and proliferate in several phagocytic and non‑phagocytic cell types. Human brucellosis has similar clinical symptoms with systemic diseases, which may lead to delay of diagnosis and increasing of complications. Therefore, investigating the proliferation of Brucella in host cells is important to understand the pathogenesis of the disease. Dihydroartemisinin (DHA), a semi‑synthetic derivative of artemisinin, has been recommended by World Health Organization as an anti‑malarial drug. However, there have been few studies regarding its effectiveness against bacteria. In the present study, it was revealed that B. suis vaccine strain 2 (S2) grew in BV2 cells without significant cytotoxicity, and less than 20 µM DHA had no inhibitory effects on BV2 cells. Furthermore, DHA reduced B. suis S2 growth in BV2 cells, and increased the percentage of apoptosis and the expression of cleaved caspase‑3 in B. suis S2‑infected cells. Collectively, the present data indicated that DHA induced the caspase‑dependent apoptotic pathway to inhibit the intracellular B. suis S2 growth.
Collapse
Affiliation(s)
- Juan Yang
- Department of Neurology, The General Hospital of Ningxia Medical University, Yinchuan, Ningxia Hui Autonomous Region 750004, P.R. China
| | - Haining Li
- Department of Neurology, The General Hospital of Ningxia Medical University, Yinchuan, Ningxia Hui Autonomous Region 750004, P.R. China
| | - Zhao Wang
- Department of Neurology, The General Hospital of Ningxia Medical University, Yinchuan, Ningxia Hui Autonomous Region 750004, P.R. China
| | - Liming Yu
- Department of Neurology, The General Hospital of Ningxia Medical University, Yinchuan, Ningxia Hui Autonomous Region 750004, P.R. China
| | - Qiang Liu
- Department of Neurology, The General Hospital of Ningxia Medical University, Yinchuan, Ningxia Hui Autonomous Region 750004, P.R. China
| | - Xiaoyan Niu
- Department of Neurology, The General Hospital of Ningxia Medical University, Yinchuan, Ningxia Hui Autonomous Region 750004, P.R. China
| | - Ting Xu
- Department of Neurology, The General Hospital of Ningxia Medical University, Yinchuan, Ningxia Hui Autonomous Region 750004, P.R. China
| | - Zhenhai Wang
- Department of Neurology, The General Hospital of Ningxia Medical University, Yinchuan, Ningxia Hui Autonomous Region 750004, P.R. China
| |
Collapse
|
8
|
Micropatterning of a 2-methacryloyloxyethyl phosphorylcholine polymer surface by hydrogenated amorphous carbon thin films for endothelialization and antithrombogenicity. Acta Biomater 2019; 87:187-196. [PMID: 30710709 DOI: 10.1016/j.actbio.2019.01.059] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2018] [Revised: 12/19/2018] [Accepted: 01/29/2019] [Indexed: 11/23/2022]
Abstract
The existing first-generation drug-eluting stent (DES) has caused late and very late stent thrombosis related to incomplete stent endothelialization. Hence, biomaterials that possess sufficient anti-thrombogenicity and endothelialization with the controlled drug release system have been highly required. In this work, we have developed a newly designed drug-release platform composed of 2-methacryloyloxyethyl phosphorylcholine (MPC) polymer, a non-thrombogenic polymer, and micropatterned hydrogenated amorphous carbon (a-C:H), a cell-compatible thin film. The platelet adhesion and the endothelial cell adhesion behavior on the micropatterned substrates were investigated in vitro. The results indicated that the micropatterned a-C:H/MPC polymer substrates effectively supported the human umbilical vein endothelial cell (HUVEC) proliferation, while suppressing the platelet adhesion. Interestingly, the HUVEC exhibited different shape and behavior by changing the island size of the micropatterned a-C:H. By introducing both a non-thrombogenic polymer and cell-compatible thin films through a simple patterning method, we demonstrated that the platform had the potential to be utilized as a base material for DES with cell controllability. STATEMENT OF SIGNIFICANCE: The current first-generation drug-eluting stents (DES) would cause late and very late stent thrombosis due to the incomplete endothelialization of the metal stent material. In this work, we have developed a new DES platform composed of a 2-methacryloyloxyethyl phosphorylcholine (MPC) polymer micropatterned by hydrogenated amorphous carbon (a-C:H). Two types of differently micropatterned a-C:H stent surface were made. Our studies revealed that the micropatterned a-C:H/MPC polymer substrates could effectively enhance the endothelial cell (EC) proliferation, simultaneously suppressing the platelet adhesion, becoming a highly biocompatible material especially for indwelling devices including a drug-release device. The new drug-release platform could be utilized as a base material for cell-controllable coating on DES.
Collapse
|
9
|
Hang R, Liu S, Liu Y, Zhao Y, Bai L, Jin M, Zhang X, Huang X, Yao X, Tang B. Preparation, characterization, corrosion behavior and cytocompatibility of NiTiO 3 nanosheets hydrothermally synthesized on biomedical NiTi alloy. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2018; 97:715-722. [PMID: 30678960 DOI: 10.1016/j.msec.2018.12.124] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/09/2018] [Revised: 12/12/2018] [Accepted: 12/27/2018] [Indexed: 10/27/2022]
Abstract
The present work reports on the hydrothermal synthesis of nanosheets on biomedical NiTi alloy in pure water. The results show rhombohedral NiTiO3 nanosheets with thickness of 6 nm can be grown at 200 °C. Hydrothermal treatment enhances the corrosion resistance of the NiTi alloy. 30 min of the treatment significantly reduces Ni ion release, while prolonged hydrothermal time results in increased Ni ion release because of the growth of the nanosheets with large specific surface area. Excitingly, the nanosheets can well support cell growth, which suggests the release amount can be well tolerated. Good corrosion resistance and cytocompatibility combined with large specific surface area render the nanosheets promising as safe and efficient drug carriers of the biomedical NiTi alloy.
Collapse
Affiliation(s)
- Ruiqiang Hang
- Research Institute of Surface Engineering, College of Materials Science and Engineering, Taiyuan University of Technology, Taiyuan 030024, China.
| | - Si Liu
- Research Institute of Surface Engineering, College of Materials Science and Engineering, Taiyuan University of Technology, Taiyuan 030024, China
| | - Yanlian Liu
- Research Institute of Surface Engineering, College of Materials Science and Engineering, Taiyuan University of Technology, Taiyuan 030024, China
| | - Ya Zhao
- Research Institute of Surface Engineering, College of Materials Science and Engineering, Taiyuan University of Technology, Taiyuan 030024, China
| | - Long Bai
- Research Institute of Surface Engineering, College of Materials Science and Engineering, Taiyuan University of Technology, Taiyuan 030024, China
| | - Minghan Jin
- Research Institute of Surface Engineering, College of Materials Science and Engineering, Taiyuan University of Technology, Taiyuan 030024, China
| | - Xiangyu Zhang
- Research Institute of Surface Engineering, College of Materials Science and Engineering, Taiyuan University of Technology, Taiyuan 030024, China
| | - Xiaobo Huang
- Research Institute of Surface Engineering, College of Materials Science and Engineering, Taiyuan University of Technology, Taiyuan 030024, China
| | - Xiaohong Yao
- Research Institute of Surface Engineering, College of Materials Science and Engineering, Taiyuan University of Technology, Taiyuan 030024, China.
| | - Bin Tang
- Research Institute of Surface Engineering, College of Materials Science and Engineering, Taiyuan University of Technology, Taiyuan 030024, China
| |
Collapse
|
10
|
Hang R, Liu Y, Bai L, Zhang X, Huang X, Jia H, Tang B. Length-dependent corrosion behavior, Ni2+ release, cytocompatibility, and antibacterial ability of Ni-Ti-O nanopores anodically grown on biomedical NiTi alloy. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2018; 89:1-7. [DOI: 10.1016/j.msec.2018.03.018] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/01/2017] [Revised: 01/16/2018] [Accepted: 03/20/2018] [Indexed: 11/26/2022]
|
11
|
Filova E, Vandrovcova M, Jelinek M, Zemek J, Houdkova J, Kocourek T, Stankova L, Bacakova L. Adhesion and differentiation of Saos-2 osteoblast-like cells on chromium-doped diamond-like carbon coatings. JOURNAL OF MATERIALS SCIENCE. MATERIALS IN MEDICINE 2017; 28:17. [PMID: 28000113 DOI: 10.1007/s10856-016-5830-2] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/03/2016] [Accepted: 12/08/2016] [Indexed: 06/06/2023]
Abstract
Diamond-like carbon (DLC) thin films are promising for use in coating orthopaedic, dental and cardiovascular implants. The problem of DLC layers lies in their weak layer adhesion to metal implants. Chromium is used as a dopant for improving the adhesion of DLC films. Cr-DLC layers were prepared by a hybrid technology, using a combination of pulsed laser deposition (PLD) from a graphite target and magnetron sputtering. Depending on the deposition conditions, the concentration of Cr in the DLC layers moved from zero to 10.0 at.%. The effect of DLC layers with 0.0, 0.9, 1.8, 7.3, 7.7 and 10.0 at.% Cr content on the adhesion and osteogenic differentiation of human osteoblast-like Saos-2 cells was assessed in vitro. The DLC samples that contained 7.7 and 10.0 at.% of Cr supported cell spreading on day 1 after seeding. On day three after seeding, the most apparent vinculin-containing focal adhesion plaques were also found on samples with higher concentrations of chromium. On the other hand, the expression of type I collagen and alkaline phosphatase at the mRNA and protein level was the highest on Cr-DLC samples with a lower concentration of Cr (0-1.8 at.%). We can conclude that higher concentrations of chromium supported cell adhesion; however DLC and DLC doped with a lower concentration of chromium supported osteogenic cell differentiation.
Collapse
Affiliation(s)
- Elena Filova
- Department of Biomaterials and Tissue Engineering, Institute of Physiology of the Czech Academy of Sciences, Videnska 1083, 142 20, Prague 4, Czech Republic
| | - Marta Vandrovcova
- Department of Biomaterials and Tissue Engineering, Institute of Physiology of the Czech Academy of Sciences, Videnska 1083, 142 20, Prague 4, Czech Republic.
| | - Miroslav Jelinek
- Institute of Physics, Academy of Sciences of the Czech Republic, Na Slovance 2, 182 21, Prague 8, Czech Republic
- Czech Technical University in Prague, Faculty of Biomedical Engineering, Nam. Sitna 3105, 272 01, Kladno, Czech Republic
| | - Josef Zemek
- Institute of Physics, Academy of Sciences of the Czech Republic, Na Slovance 2, 182 21, Prague 8, Czech Republic
| | - Jana Houdkova
- Institute of Physics, Academy of Sciences of the Czech Republic, Na Slovance 2, 182 21, Prague 8, Czech Republic
| | - Tomas Kocourek
- Institute of Physics, Academy of Sciences of the Czech Republic, Na Slovance 2, 182 21, Prague 8, Czech Republic
- Czech Technical University in Prague, Faculty of Biomedical Engineering, Nam. Sitna 3105, 272 01, Kladno, Czech Republic
| | - Lubica Stankova
- Department of Biomaterials and Tissue Engineering, Institute of Physiology of the Czech Academy of Sciences, Videnska 1083, 142 20, Prague 4, Czech Republic
| | - Lucie Bacakova
- Department of Biomaterials and Tissue Engineering, Institute of Physiology of the Czech Academy of Sciences, Videnska 1083, 142 20, Prague 4, Czech Republic
| |
Collapse
|