1
|
Liang K, Ding C, Li J, Yao X, Yu J, Wu H, Chen L, Zhang M. A Review of Advanced Abdominal Wall Hernia Patch Materials. Adv Healthc Mater 2024; 13:e2303506. [PMID: 38055999 DOI: 10.1002/adhm.202303506] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2023] [Revised: 12/05/2023] [Indexed: 12/08/2023]
Abstract
Tension-free abdominal wall hernia patch materials (AWHPMs) play an important role in the repair of abdominal wall defects (AWDs), which have a recurrence rate of <1%. Nevertheless, there are still significant challenges in the development of tailored, biomimetic, and extracellular matrix (ECM)-like AWHPMs that satisfy the clinical demands of abdominal wall repair (AWR) while effectively handling post-operative complications associated with abdominal hernias, such as intra-abdominal visceral adhesion and abnormal healing. This extensive review presents a comprehensive guide to the high-end fabrication and the precise selection of these advanced AWHPMs. The review begins by briefly introducing the structures, sources, and properties of AWHPMs, and critically evaluates the advantages and disadvantages of different types of AWHPMs for AWR applications. The review subsequently summarizes and elaborates upon state-of-the-art AWHPM fabrication methods and their key characteristics (e.g., mechanical, physicochemical, and biological properties in vitro/vivo). This review uses compelling examples to demonstrate that advanced AWHPMs with multiple functionalities (e.g., anti-deformation, anti-inflammation, anti-adhesion, pro-healing properties, etc.) can meet the fundamental clinical demands required to successfully repair AWDs. In particular, there have been several developments in the enhancement of biomimetic AWHPMs with multiple properties, and additional breakthroughs are expected in the near future.
Collapse
Affiliation(s)
- Kaiwen Liang
- College of Material Engineering, Fujian Agriculture and Forestry University, Fuzhou, Fujian, 350002, P. R. China
| | - Cuicui Ding
- College of Ecological Environment and Urban Construction, Fujian University of Technology, Fuzhou, Fujian, 350118, P. R. China
| | - Jingyi Li
- School of Basic Medicine, Fujian Medical University, Fuzhou, Fujian, 350122, P. R. China
| | - Xiao Yao
- College of Ecological Environment and Urban Construction, Fujian University of Technology, Fuzhou, Fujian, 350118, P. R. China
| | - Jingjing Yu
- College of Ecological Environment and Urban Construction, Fujian University of Technology, Fuzhou, Fujian, 350118, P. R. China
| | - Hui Wu
- College of Material Engineering, Fujian Agriculture and Forestry University, Fuzhou, Fujian, 350002, P. R. China
| | - Lihui Chen
- College of Material Engineering, Fujian Agriculture and Forestry University, Fuzhou, Fujian, 350002, P. R. China
| | - Min Zhang
- College of Material Engineering, Fujian Agriculture and Forestry University, Fuzhou, Fujian, 350002, P. R. China
- National Forestry & Grassland Administration Key Laboratory for Plant Fiber Functional Materials, Fuzhou, Fujian, 350000, P. R. China
| |
Collapse
|
2
|
Liang J, Liu P, Yang X, Liu L, Zhang Y, Wang Q, Zhao H. Biomaterial-based scaffolds in promotion of cartilage regeneration: Recent advances and emerging applications. J Orthop Translat 2023; 41:54-62. [PMID: 37691640 PMCID: PMC10485599 DOI: 10.1016/j.jot.2023.08.006] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/08/2023] [Revised: 07/07/2023] [Accepted: 08/05/2023] [Indexed: 09/12/2023] Open
Abstract
Osteoarthritis (OA) poses a significant burden for countless individuals, inflicting relentless pain and impairing their quality of life. Although traditional treatments for OA focus on pain management and surgical interventions, they often fall short of addressing the underlying cause of the disease. Fortunately, emerging biomaterial-based scaffolds offer hope for OA therapy, providing immense promise for cartilage regeneration in OA. These innovative scaffolds are ingeniously designed to provide support and mimic the intricate structure of the natural extracellular matrix, thus stimulating the regeneration of damaged cartilage. In this comprehensive review, we summarize and discuss current landscape of biomaterial-based scaffolds for cartilage regeneration in OA. Furthermore, we delve into the diverse range of biomaterials employed in their construction and explore the cutting-edge techniques utilized in their fabrication. By examining both preclinical and clinical studies, we aim to illuminate the remarkable versatility and untapped potential of biomaterial-based scaffolds in the context of OA. Thetranslational potential of this article By thoroughly examining the current state of research and clinical studies, this review provides valuable insights that bridge the gap between scientific knowledge and practical application. This knowledge is crucial for clinicians and researchers who strive to develop innovative treatments that go beyond symptom management and directly target the underlying cause of OA. Through the comprehensive analysis and multidisciplinary approach, the review paves the way for the translation of scientific knowledge into practical applications, ultimately improving the lives of individuals suffering from OA and shaping the future of orthopedic medicine.
Collapse
Affiliation(s)
| | | | - Xinquan Yang
- Department of Foot and Ankle Surgery, Honghui Hospital of Xi'an Jiaotong University, Xi'an, China
| | - Liang Liu
- Department of Foot and Ankle Surgery, Honghui Hospital of Xi'an Jiaotong University, Xi'an, China
| | - Yan Zhang
- Department of Foot and Ankle Surgery, Honghui Hospital of Xi'an Jiaotong University, Xi'an, China
| | - Qiong Wang
- Department of Foot and Ankle Surgery, Honghui Hospital of Xi'an Jiaotong University, Xi'an, China
| | - Hongmou Zhao
- Department of Foot and Ankle Surgery, Honghui Hospital of Xi'an Jiaotong University, Xi'an, China
| |
Collapse
|
3
|
Fontana-Escartín A, El Hauadi K, Lanzalaco S, Pérez-Madrigal MM, Armelin E, Turon P, Alemán C. Preparation and Characterization of Functionalized Surgical Meshes for Early Detection of Bacterial Infections. ACS Biomater Sci Eng 2023; 9:1104-1115. [PMID: 36693280 PMCID: PMC10889595 DOI: 10.1021/acsbiomaterials.2c01319] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Abstract
Isotactic polypropylene (i-PP) nonabsorbable surgical meshes are modified by incorporating a conducting polymer (CP) layer to detect the adhesion and growth of bacteria by sensing the oxidation of nicotinamide adenine dinucleotide (NADH), a metabolite produced by the respiration reactions of such microorganisms, to NAD+. A three-step process is used for such incorporation: (1) treat pristine meshes with low-pressure O2 plasma; (2) functionalize the surface with CP nanoparticles; and (3) coat with a homogeneous layer of electropolymerized CP using the nanoparticles introduced in (2) as polymerization nuclei. The modified meshes are stable and easy to handle and also show good electrochemical response. The detection by cyclic voltammetry of NADH within the interval of concentrations reported for bacterial cultures is demonstrated for the two modified meshes. Furthermore, Staphylococcus aureus and both biofilm-positive (B+) and biofilm-negative (B-) Escherichia coli cultures are used to prove real-time monitoring of NADH coming from aerobic respiration reactions. The proposed strategy, which offers a simple and innovative process for incorporating a sensor for the electrochemical detection of bacteria metabolism to currently existing surgical meshes, holds considerable promise for the future development of a new generation of smart biomedical devices to fight against post-operative bacterial infections.
Collapse
Affiliation(s)
- Adrián Fontana-Escartín
- Departament d'Enginyeria Química and Barcelona Research Center for Multiscale Science and Engineering, EEBE, Universitat Politècnica de Catalunya, C/ Eduard Maristany, 10-14, 08019Barcelona, Spain
| | - Karima El Hauadi
- Departament d'Enginyeria Química and Barcelona Research Center for Multiscale Science and Engineering, EEBE, Universitat Politècnica de Catalunya, C/ Eduard Maristany, 10-14, 08019Barcelona, Spain
| | - Sonia Lanzalaco
- Departament d'Enginyeria Química and Barcelona Research Center for Multiscale Science and Engineering, EEBE, Universitat Politècnica de Catalunya, C/ Eduard Maristany, 10-14, 08019Barcelona, Spain
| | - Maria M Pérez-Madrigal
- Departament d'Enginyeria Química and Barcelona Research Center for Multiscale Science and Engineering, EEBE, Universitat Politècnica de Catalunya, C/ Eduard Maristany, 10-14, 08019Barcelona, Spain
| | - Elaine Armelin
- Departament d'Enginyeria Química and Barcelona Research Center for Multiscale Science and Engineering, EEBE, Universitat Politècnica de Catalunya, C/ Eduard Maristany, 10-14, 08019Barcelona, Spain
| | - Pau Turon
- B. Braun Surgical, S.A.U., Carretera de Terrassa 121, 08191Rubí (Barcelona), Spain
| | - Carlos Alemán
- Departament d'Enginyeria Química and Barcelona Research Center for Multiscale Science and Engineering, EEBE, Universitat Politècnica de Catalunya, C/ Eduard Maristany, 10-14, 08019Barcelona, Spain
- Institute for Bioengineering of Catalonia (IBEC), The Barcelona Institute of Science and Technology, Baldiri Reixac 10-12, 08028Barcelona, Spain
| |
Collapse
|
4
|
Hu Q, Wu J, Zhang H, Dong W, Gu Y, Liu S. Designing Double-Layer Multi-Material Composite Patch Scaffold with Adhesion Resistance for Hernia Repair. Macromol Biosci 2022; 22:e2100510. [PMID: 35471592 DOI: 10.1002/mabi.202100510] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2021] [Revised: 04/12/2022] [Indexed: 11/10/2022]
Abstract
Hernia repair mesh is associated with a number of complications, including adhesions and limited mobility, due to insufficient mechanical strength and non-resorbability. Among them, visceral adhesions are one of the most serious complications of patch repair. In this study, a degradable patch with an anti-adhesive layer was prepared for hernia repair by 3D printing and electrospinning techniques using polycaprolactone (PCL), polyvinyl alcohol (PVA), and soybean peptide (SP). The study into the physicochemical properties of the patch was found that it had adequate mechanical strength requirements (16 N cm-1 ) and large elongation at break, which were superior than commercial polypropylene (PP) patches. In vivo and in vitro experiments showed that human umbilical vein endothelial cells (HUVECs) proliferated well on composite patches, and showed excellent biocompatibility with the host and little adhesion through a rat abdominal wall defect model. In conclusion, the results of this study show that composite patch can effectively reduce the occurrence of adhesions, while the addition of SP in the patch further enhances its biocompatibility. We believe that a regenerative biological patch with great potential in hernia repair provides a new strategy for the development of new biomimetic biodegradable patches. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- Qingxi Hu
- Rapid Manufacturing Engineering Center, School of Mechatronical Engineering and Automation, Shanghai University, Shanghai, 200444, China.,Shanghai Key Laboratory of Intelligent Manufacturing and Robotics, Shanghai University, Shanghai, 200072, China.,National Demonstration Center for Experimental Engineering Training Education, Shanghai University, Shanghai, 200444, China
| | - Junjie Wu
- Rapid Manufacturing Engineering Center, School of Mechatronical Engineering and Automation, Shanghai University, Shanghai, 200444, China
| | - Haiguang Zhang
- Rapid Manufacturing Engineering Center, School of Mechatronical Engineering and Automation, Shanghai University, Shanghai, 200444, China.,Shanghai Key Laboratory of Intelligent Manufacturing and Robotics, Shanghai University, Shanghai, 200072, China.,National Demonstration Center for Experimental Engineering Training Education, Shanghai University, Shanghai, 200444, China
| | - Wenpei Dong
- Department of General Surgery, Huadong Hospital, Fudan University, Shanghai, 200040, China
| | - Yan Gu
- Department of General Surgery, Huadong Hospital, Fudan University, Shanghai, 200040, China
| | - Suihong Liu
- Rapid Manufacturing Engineering Center, School of Mechatronical Engineering and Automation, Shanghai University, Shanghai, 200444, China
| |
Collapse
|
5
|
Atiyeh BS, Costagliola M, Rampillon F, Chahine F. Comment on Plane Change Versus Capsulotomy: A Comparison of Treatments for Capsular Contraction in Breast Augmentation Using the Subfascial Plane. Aesthetic Plast Surg 2021; 45:1360-1362. [PMID: 33399952 DOI: 10.1007/s00266-020-02072-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2020] [Accepted: 11/24/2020] [Indexed: 11/30/2022]
Affiliation(s)
- Bishara S Atiyeh
- Division of Plastic and Reconstructive Surgery, American University of Beirut Medical Center, Beirut, Lebanon
| | - Michel Costagliola
- Faculté de Médecine Toulouse-Rangueil, Pr Emérite-Chirurgie Réparatrice et Esthétique, Toulouse, France
| | | | | |
Collapse
|
6
|
Hu Q, Zhang R, Zhang H, Yang D, Liu S, Song Z, Gu Y, Ramalingam M. Topological Structure Design and Fabrication of Biocompatible PLA/TPU/ADM Mesh with Appropriate Elasticity for Hernia Repair. Macromol Biosci 2021; 21:e2000423. [PMID: 33870647 DOI: 10.1002/mabi.202000423] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2020] [Revised: 02/21/2021] [Indexed: 11/06/2022]
Abstract
The meshes for hernia repair result in many problems that are related to complications including chronic pain and limited movement due to inadequate mechanical strength, non-absorbability, or low elasticity. In this study, degradable polylactic acid (PLA), synthetic thermoplastic polyurethane (TPU), and acellular dermal matrix (ADM) powders are combined to prepare a novel PLA/TPU/ADM mesh with three different topological structures (square, circular, and diamond) by 3D printing. The physicochemical properties and structural characteristics of mesh are studied, the results show that the diamond structure mesh with the pore size of 3 mm has sufficient elasticity and tensile strength, which provides the efficient mechanical strength required for hernia repair (16 N cm-1 ) and the value more than polypropylene(PP) mesh. Besides, in vitro and in vivo experiments demonstrate human umbilical vein endothelial cells could successfully proliferate on the PLA/TPU/ADM mesh whose biocompatibility with the host is shown using a rat model of abdominal wall defect. In conclusion, the results of this study demonstrate that the PLA/TPU/ADM mesh may be considered a good choice for hernia repair as its potential to overcome the elastic and strength challenges associated with a highly flexible abdominal wall, as well as its good biocompatibility.
Collapse
Affiliation(s)
- Qingxi Hu
- Rapid Manufacturing Engineering Center, Shanghai University, Shanghai, 200444, China.,Shanghai Key Laboratory of Intelligent Manufacturing and Robotics, Shanghai University, Shanghai, 200072, China
| | - Rennan Zhang
- Rapid Manufacturing Engineering Center, Shanghai University, Shanghai, 200444, China
| | - Haiguang Zhang
- Rapid Manufacturing Engineering Center, Shanghai University, Shanghai, 200444, China.,Shanghai Key Laboratory of Intelligent Manufacturing and Robotics, Shanghai University, Shanghai, 200072, China
| | - Dongchao Yang
- Department of General Surgery, Shanghai Ninth People's Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, 200011, China
| | - Suihong Liu
- Rapid Manufacturing Engineering Center, Shanghai University, Shanghai, 200444, China
| | - Zhicheng Song
- Department of General Surgery, Shanghai Ninth People's Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, 200011, China
| | - Yan Gu
- Department of General Surgery, Shanghai Ninth People's Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, 200011, China
| | - Murugan Ramalingam
- Biomaterials and Organ Engineering Group, Centre for Biomaterials, Cellular and Molecular Theranostics, School of Mechanical Engineering, Vellore Institute of Technology, Vellore, 632014, India
| |
Collapse
|
7
|
Tomaszewska A, Lubowiecka I, Szymczak C. Mechanics of mesh implanted into abdominal wall under repetitive load. Experimental and numerical study. J Biomed Mater Res B Appl Biomater 2018; 107:1400-1409. [DOI: 10.1002/jbm.b.34232] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2018] [Revised: 07/25/2018] [Accepted: 08/18/2018] [Indexed: 01/06/2023]
Affiliation(s)
- Agnieszka Tomaszewska
- Gdańsk University of TechnologyFaculty of Civil and Environmental Engineering, Department of Structural Mechanics Narutowicza 11/12, 80‐233, Gdańsk Poland
| | - Izabela Lubowiecka
- Gdańsk University of TechnologyFaculty of Civil and Environmental Engineering, Department of Structural Mechanics Narutowicza 11/12, 80‐233, Gdańsk Poland
| | - Czesław Szymczak
- Gdańsk University of TechnologyFaculty of Ocean Engineering and Ship Technology, Department of Structural Mechanics Narutowicza 11/12, 80‐233, Gdańsk Poland
| |
Collapse
|
8
|
Heise D, Eickhoff R, Kroh A, Binnebösel M, Klinge U, Klink CD, Neumann UP, Lambertz A. Elastic TPU Mesh as Abdominal Wall Inlay Significantly Reduces Defect Size in a Minipig Model. J INVEST SURG 2018; 32:501-506. [PMID: 29469618 DOI: 10.1080/08941939.2018.1436207] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
Background: The open abdomen with mesh implantation, followed by early reoperation with fascial closure, is a modern surgical approach in difficult clinical situations such as severe abdominal sepsis. As early fascial closure is not possible in many cases, mesh-mediated fascial traction is helpful for conditioning of a minimized ventral hernia after open abdomen. The aim of this study was to evaluate the clinical utilization of an innovative elastic thermoplastic polyurethane mesh (TPU) as an abdominal wall inlay in a minipig model. Methods: Ten minipigs were divided in two groups, either receiving an elastic TPU mesh or a nonelastic polyvinylidene fluoride (PVDF) mesh in inlay position of the abdominal wall. After 8 weeks, mesh expansion and abdominal wall defect size were measured. Finally, pigs were euthanized and abdominal walls were explanted for histological and immunohistochemical assessment. Results: Eight weeks after abdominal wall replacement, transversal diameter of the fascial defect in the TPU group was significantly smaller than in the PVDF group (4.5 cm vs. 7.4 cm; p = 0.047). Immunhistochemical analysis showed increased Ki67 positive cells (p = 0.003) and a higher number of apoptotic cells (p = 0.047) after abdominal wall replacement with a TPU mesh. Collagen type I/III ratio was increased in the PVDF group (p = 0.011). Conclusion: Implantation of an elastic TPU mesh as abdominal wall inlay is a promising approach to reduce the size of the ventral hernia after open abdomen by mesh-mediated traction. However, this effect was associated with a slightly increased foreign body reaction in comparison to the nonelastic PVDF.
Collapse
Affiliation(s)
- D Heise
- Department of General, Visceral and Transplantation Surgery, RWTH Aachen University Hospital, Aachen, Germany
| | - R Eickhoff
- Department of General, Visceral and Transplantation Surgery, RWTH Aachen University Hospital, Aachen, Germany
| | - A Kroh
- Department of General, Visceral and Transplantation Surgery, RWTH Aachen University Hospital, Aachen, Germany
| | - M Binnebösel
- Department of General, Visceral and Transplantation Surgery, RWTH Aachen University Hospital, Aachen, Germany
| | - U Klinge
- Department of General, Visceral and Transplantation Surgery, RWTH Aachen University Hospital, Aachen, Germany
| | - C D Klink
- Department of General, Visceral and Transplantation Surgery, RWTH Aachen University Hospital, Aachen, Germany
| | - U P Neumann
- Department of General, Visceral and Transplantation Surgery, RWTH Aachen University Hospital, Aachen, Germany.,Department of General Surgery, Maastricht University Medical Centre, Maastricht, The Netherlands
| | - A Lambertz
- Department of General, Visceral and Transplantation Surgery, RWTH Aachen University Hospital, Aachen, Germany
| |
Collapse
|
9
|
Modelling of compressible and orthotropic surgical mesh implants based on optical deformation measurement. J Mech Behav Biomed Mater 2017; 74:400-410. [DOI: 10.1016/j.jmbbm.2017.06.012] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2017] [Revised: 06/06/2017] [Accepted: 06/09/2017] [Indexed: 12/29/2022]
|