Khan SA, Rahman ZU, Javed A, Ahmad Z, Cai Z, Jiang O, Xu G. Natural biopolymers in the fabrication and coating of ureteral stent: An overview. BIOMATERIALS ADVANCES 2024; 165:214009. [PMID: 39216319 DOI: 10.1016/j.bioadv.2024.214009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/10/2024] [Revised: 08/26/2024] [Accepted: 08/27/2024] [Indexed: 09/04/2024]
Abstract
Ureteral stents are indwelling medical devices that are most commonly used in treating different urinary tract complications like ureteral obstruction, kidney stones, and strictures, and allow normal urine flow from the kidney to the bladder. Tremendous work has been done in ureteral stent technology to meet the clinical demands, however, till-date a gold standard material for ureteral stents has not yet been developed. Many materials such as metal, and synthetic polymers have been published, however, the role of natural biopolymers has not yet been summarized and discussed. There is no detailed review published to explain the role of natural biopolymers in ureteral stent technology. This is the first review that explains and summarizes the role of natural polymer in ureter stent technology. In this review alginate and chitosan polymers are discussed in detail in the fabrications and coating of ureteral stents. It was summarized that alginate polymer alone or in combination with other polymers have been successfully used by many researchers for the manufacturing of ureteral stents with satisfactory results in vitro, in vivo, and clinical trials. However, alginate is rarely used to coat the surface of ureteral stent. On the other hand, only two reports are available on chitosan polymers for the manufacturing of ureteral stents, however, chitosan is largely used to coat the existing ureteral stents owing to their good antibacterial characteristics. Coating procedures can inhibit encrustation and biofilm formation. Nevertheless, the lack of antibacterial efficiency and inadequate coating limit their applications, however, natural biopolymers like chitosan showed significant promises in coating. Overall, the renewable nature, abundant, biocompatible, and biodegradable potential of natural polymer can be established with significant aspects as the ideal ureteral stent. To fully utilize the potential of the natural biopolymers in the ureteral stent design or coatings, an in-depth study is required to understand and identify their performance both in vitro and in vivo in the urinary tract.
Collapse
Affiliation(s)
- Shahid Ali Khan
- Department of Urology, Key Laboratory of Biological Targeting Diagnosis, Therapy and Rehabilitation of Guangdong Higher Education Institutes, The Fifth Affiliated Hospital of Guangzhou Medical University, Guangzhou Medical University, Guangzhou 510700, China; Department of Chemistry, School of Natural Sciences, National University of Science and Technology (NUST), Islamabad 44000, Pakistan
| | - Zia Ur Rahman
- Department of Chemistry, University of Swabi, Anbar 23561, Khyber Pakhtunkhwa, Pakistan
| | - Aimen Javed
- Department of Chemistry, School of Natural Sciences, National University of Science and Technology (NUST), Islamabad 44000, Pakistan
| | - Zubair Ahmad
- Department of Chemistry, University of Swabi, Anbar 23561, Khyber Pakhtunkhwa, Pakistan
| | - Zhiduan Cai
- Department of Urology, Key Laboratory of Biological Targeting Diagnosis, Therapy and Rehabilitation of Guangdong Higher Education Institutes, The Fifth Affiliated Hospital of Guangzhou Medical University, Guangzhou Medical University, Guangzhou 510700, China
| | - Ouyang Jiang
- School of Biomedical Engineering, Guangzhou Medical University, Guangzhou 511436, China
| | - Guibin Xu
- Department of Urology, Key Laboratory of Biological Targeting Diagnosis, Therapy and Rehabilitation of Guangdong Higher Education Institutes, The Fifth Affiliated Hospital of Guangzhou Medical University, Guangzhou Medical University, Guangzhou 510700, China.
| |
Collapse
|
2
|
Jones DS, Westwood M, Li S, Andrews GP. Spectroscopic and Thermal Characterisation of Interpenetrating Hydrogel Networks (IHNs) Based on Polymethacrylates and Pluronics, and Their Physicochemical Stability under Aqueous Conditions. Polymers (Basel) 2024; 16:2796. [PMID: 39408506 PMCID: PMC11478580 DOI: 10.3390/polym16192796] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2024] [Revised: 09/22/2024] [Accepted: 09/23/2024] [Indexed: 10/20/2024] Open
Abstract
This study describes the physicochemical characterisation of interpenetrating hydrogel networks (IHNs) composed of either poly(hydroxyethylmethacrylate, p(HEMA)) or poly(methacrylic acid, p(MAA)), and Pluronic block copolymers (grades F127, P123 and L121). IHNs were prepared by mixing the acrylate monomer with Pluronic block copolymers followed by free radical polymerisation. p(HEMA)-Pluronic blends were immiscible, evident from a lack of interaction between the two components (Raman spectroscopy) and the presence of the glass transitions (differential scanning calorimetry, DSC) of the two components. Conversely, IHNs of p(MAA) and each Pluronic were miscible, displaying a single glass transition and secondary bonding between the carbonyl group of p(MAA) and the ether groups in the Pluronic block copolymers (Raman and ATR-FTIR spectroscopy). The effect of storage of the IHNs in Tris buffer on the physical state of each Pluronic and on the loss of Pluronic from the IHNs were studied using DSC and gravimetric analysis, respectively. Pluronic loss from the IHNs was dependent on the grade of Pluronic, time of immersion in Tris buffer, and the nature of the IHN (p(HEMA) or p(MAA)). At equilibrium, the loss was greater from p(HEMA) than from p(MAA) IHNs, whereas increasing ratio of poly(propylene oxide) to poly(ethylene oxide) decreased Pluronic loss. The retention of each Pluronic grade was shown to be primarily due to its micellization; however, hydrogen bonding between Pluronic and p(MAA) (but not p(HEMA)) IHNs contributed to their retention.
Collapse
Affiliation(s)
- David S. Jones
- School of Pharmacy, Queen’s University of Belfast, 97, Lisburn Road, Belfast BT9 7BL, UK (S.L.); (G.P.A.)
| | | | | | | |
Collapse
|
3
|
Hu K, Hou Z, Huang Y, Li X, Li X, Yang L. Recent development and future application of biodegradable ureteral stents. Front Bioeng Biotechnol 2024; 12:1373130. [PMID: 38572363 PMCID: PMC10987965 DOI: 10.3389/fbioe.2024.1373130] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2024] [Accepted: 03/06/2024] [Indexed: 04/05/2024] Open
Abstract
Ureteral stenting is a common clinical procedure for the treatment of upper urinary tract disorders, including conditions such as urinary tract infections, tumors, stones, and inflammation. Maintaining normal renal function by preventing and treating ureteral obstruction is the primary goal of this procedure. However, the use of ureteral stents is associated with adverse effects, including surface crusting, bacterial adhesion, and lower urinary tract symptoms (LUTS) after implantation. Recognizing the need to reduce the complications associated with permanent ureteral stent placement, there is a growing interest among both physicians and patients in the use of biodegradable ureteral stents (BUS). The evolution of stent materials and the exploration of different stent coatings have given these devices different roles tailored to different clinical needs, including anticolithic, antibacterial, antitumor, antinociceptive, and others. This review examines recent advances in BUS within the last 5 years, providing an in-depth analysis of their characteristics and performance. In addition, we present prospective insights into the future applications of BUS in clinical settings.
Collapse
Affiliation(s)
- Ke Hu
- Department of Urology, The Second Affiliated Hospital of Dalian Medical University, Dalian, China
- Research Center for Biomedical Materials, Engineering Research Center of Ministry of Education for Minimally Invasive Gastrointestinal Endoscopic Techniques, Shengjing Hospital of China Medical University, Shenyang, China
| | - Zhipeng Hou
- Research Center for Biomedical Materials, Engineering Research Center of Ministry of Education for Minimally Invasive Gastrointestinal Endoscopic Techniques, Shengjing Hospital of China Medical University, Shenyang, China
| | - Yuanbin Huang
- Department of Urology, The Second Affiliated Hospital of Dalian Medical University, Dalian, China
| | - Xueying Li
- College of Computer Science and Engineering, Dalian Minzu University, Dalian, China
| | - Xiancheng Li
- Department of Urology, The Second Affiliated Hospital of Dalian Medical University, Dalian, China
| | - Liqun Yang
- Research Center for Biomedical Materials, Engineering Research Center of Ministry of Education for Minimally Invasive Gastrointestinal Endoscopic Techniques, Shengjing Hospital of China Medical University, Shenyang, China
- Liaoning Research Institute for Eugenic Birth and Fertility, China Medical University, Shenyang, China
| |
Collapse
|
4
|
Awonusi BO, Li H, Yin Z, Zhao J, Yang K, Li J. Surface Modification of Zn-Cu Alloy with Heparin Nanoparticles for Urinary Implant Applications. ACS APPLIED BIO MATERIALS 2024; 7:1748-1762. [PMID: 38428026 DOI: 10.1021/acsabm.3c01177] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/03/2024]
Abstract
In this work, an investigation on the Zn-Cu alloy coated with heparin was conducted in order to explore the potentiality of its application as a feasible alternative for biodegradable implants, with the specific goal of addressing the issue of encrustation in the urinary system. The stability of the nanoparticles were characterized by dynamic light scattering. Typical surface characterization such as X-ray photoelectron spectroscopy, scanning electron microscopy, and atomic force microscopy were used to demonstrate a successful immobilization of the NPs. The in vitro corrosion behavior was studied by potentiodynamic polarization and immersion tests in artificial urine (AU) at 37 °C. The 8 weeks in vivo degradation, encrustation resistance, hemocompatibility, and histocompatibility were investigated by means of implantation into the bladders of rats. Both in vitro and in vivo degradation tests exhibited a higher degradation rate for Zn-Cu and NPs groups when compared to pure Zn. Histological evaluations and hemocompatibility revealed that there was no tissue damage or pathological alterations caused by the degradation process. Furthermore, antiencrustation performance and urinalysis results confirmed that the modified alloy demonstrated significant encrustation inhibitory properties and bactericidal activity compared to the pure Zn control. Our findings highlight the potential of this modified alloy as an antiencrustation biodegradable ureteral stent.
Collapse
Affiliation(s)
- Bukola O Awonusi
- Institute of Metal Research, Chinese Academy of Sciences, Shenyang 110016, China
| | - Hongwei Li
- Department of Urology, General Hospital of Northern Theater Command, Shenyang 110840, China
| | - Zecheng Yin
- Institute of Information and Control Engineering, Shenyang Urban Construction University, Shenyang 110167, China
| | - Jing Zhao
- Institute of Metal Research, Chinese Academy of Sciences, Shenyang 110016, China
| | - Ke Yang
- Institute of Metal Research, Chinese Academy of Sciences, Shenyang 110016, China
| | - Jianzhong Li
- Department of Urology, General Hospital of Northern Theater Command, Shenyang 110840, China
| |
Collapse
|
5
|
Harrison NL, Hughes C, Somani BK. Is Stent on a String the New Gold Standard for Postureteroscopy Ureteral Drainage? Evidence from a Systematic Review. J Endourol 2024; 38:159-169. [PMID: 38115630 DOI: 10.1089/end.2023.0412] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2023] Open
Abstract
Introduction: Ureteral stents are widely used throughout urologic surgery, most commonly following ureteroscope (URS) procedures. This systematic review aims to assess the current evidence concerning stent on string (SOS) placed after URS and compare it with stents without strings (SWOSs). Methods: A systematic review was conducted on several databases using the preferred reporting items for systematic review and meta-analysis (PRISMA) methodology for studies in English language, for patients of all age groups, who had an SOS after URS for stone disease. Results: Of 1210 records identified, a total of 22 studies (20 adult and 2 pediatric studies) were included, with a total of 8382 patients. Of these, 3427 (40.9%) had SOSs inserted and 434 (11%) were in the pediatric age group. Our results show that SOS provides several advantages, and compared with SWOS, they were in situ for less time, with no difference in complications such as urinary tract infection or urinary symptoms. Furthermore, significant cost savings, less pain on removal, and high rates of safe home removal were reported in SOS, with >90% patients reporting that they would be happy to remove their SOSs at home. However, a small risk of stent dislodgment must be considered when making decisions regarding SOS placement after URS. Conclusion: SOS provides an excellent option after URS, especially in those patients with no intraoperative complication, and their placement is done as a routine insertion based on surgeon preference. These stents reduce dwell time, pain, cost, risks, and suffering involved from prolonged stenting, and majority of patients are happy to remove it themselves at home. Although their use seems to be still restricted in the current endourology practices, they are likely to become the new gold standard for routine URS in future, with more shared decision making and patient-reported outcome measures coming into the mainstream.
Collapse
Affiliation(s)
- Nick L Harrison
- Department of Urology, Mersey and West Lancashire Teaching Hospitals NHS Trust, Prescot, United Kingdom
| | - Charlotte Hughes
- Department of Urology, Norfolk & Norwich University Hospital, Norfolk, United Kingdom
| | - Bhaskar K Somani
- Department of Urology, University Hospital Southampton, Southampton, United Kingdom
| |
Collapse
|
6
|
Hu J, Wang Z, Hu H, Zhao J, Li H, Zhang X, Bi J, Li J. In vitro and in vivo assessment of a bilayered degradable rapamycin-eluting stent for ureteral stricture caused by holmium: YAG laser lithotripsy. Acta Biomater 2023; 172:321-329. [PMID: 37821034 DOI: 10.1016/j.actbio.2023.10.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2023] [Revised: 10/03/2023] [Accepted: 10/05/2023] [Indexed: 10/13/2023]
Abstract
Ureteral stricture caused by holmium: YAG laser lithotripsy is one of the most challenging issues for urologists. Currently, evidence for rapamycin application in reducing ureterostenosis is not sufficient. This study aimed to assess the inhibition of ureteral stricture of rapamycin-eluting stents in vitro and in vivo. A bilayered drug-eluting ureteral stent consisted of drug blending with poly (lactic-co-glycolic acid) (PU/drug stent), which was over-layered by polycaprolactone (PCL) by ultrasonic atomizing spraying. Stent morphology was observed by scanning electron microscope. A kidney-ureter-bladder model was established to simulate the stents-releasing condition, and high-performance liquid chromatography was used to measure the drug release rate. The inhibitory proliferation was detected by CCK-8. The bladder of rats was injured through electro tome, and stents were implanted for 7, 14, and 28 days. The effects of drug-eluting stents was investigated by hematoxylin-eosin staining, immunofluorescence staining, real-time quantitative polymerase chain reaction and western blot. The bilayered stents could block the burst loss of the drug and maintained a sustained delivery period because of the 5.3 μm thickness of the PCL layer. The relative growth rates of cells plotted inhibitory effect on the proliferation of human urethral scar fibroblast cells. For in vivo results of 28 days, the bilayered stent maintained structural integrity and induced less deposition of crystals, thinner and less lamina propria connective tissues were formed, and α-SMA and TGF-β1 were downregulated. Bilayered rapamycin-eluting stent is significantly effective in alleviating fibrosis in in vitro and in vivo models. STATEMENT OF SIGNIFICANCE: The occurrence of ureteral stricture resulting from holmium: YAG laser lithotripsy presents a significant challenge for urologists. Traditional double J stents have not been proven to offer a shorter indwelling time or improved inhibition of tissue blocking. While drug-eluting stents containing rapamycin, paclitaxel, and other substances have been extensively used in treating artery stenosis, there is insufficient evidence supporting their application in reducing ureterostenosis. Consequently, a biodegradable polymer ureteric scaffold incorporating rapamycin was fabricated in this study, employing ultrasonic atomization spraying technology to optimize the bilayers composed of 75/25 poly (lactic-co-glycolic acid) (PLGA) and polycaprolactone (PCL). The efficacy of the scaffold was subsequently confirmed through in vitro and in vivo experiments.
Collapse
Affiliation(s)
- Jiyuan Hu
- Department of Urology, the First Affiliated Hospital of China Medical University, Shenyang, 110002, China; Department of Urology, General Hospital of Northern Theater Command, Shenyang, 110840, China
| | - Zhenyu Wang
- Department of Urology, General Hospital of Northern Theater Command, Shenyang, 110840, China
| | - Hao Hu
- Department of Urology, Peking University People's Hospital, Beijing, 100044, China.
| | - Jing Zhao
- Institute of Metal Research, Chinese Academy of Sciences, Shenyang, 110016, China
| | - Hongwei Li
- Department of Urology, General Hospital of Northern Theater Command, Shenyang, 110840, China
| | - Xinyu Zhang
- Department of Urology, General Hospital of Northern Theater Command, Shenyang, 110840, China
| | - Jianbin Bi
- Department of Urology, the First Affiliated Hospital of China Medical University, Shenyang, 110002, China
| | - Jianzhong Li
- Department of Urology, the First Affiliated Hospital of China Medical University, Shenyang, 110002, China; Department of Urology, General Hospital of Northern Theater Command, Shenyang, 110840, China.
| |
Collapse
|
7
|
Rosenbusch L, Schuon R, Wilfling T, Krüger P, Lebahn K, John S, Sahmel O, Grabow N, Schulze M, Wree A, Schmitz KP, Stein T, Lenarz T, Paasche G. Investigation of Stent Prototypes for the Eustachian Tube in Human Donor Bodies. Bioengineering (Basel) 2023; 10:743. [PMID: 37370674 DOI: 10.3390/bioengineering10060743] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2023] [Revised: 06/07/2023] [Accepted: 06/19/2023] [Indexed: 06/29/2023] Open
Abstract
Chronic otitis media is often connected to Eustachian tube dysfunction. As successful treatment cannot be guaranteed with the currently available options, the aim is to develop a stent for the Eustachian tube (ET). Over the course of this development, different prototypes were generated and tested in ex vivo experiments. Four different prototypes of an ET stent and one commercially available coronary stent were implanted in the ET of seven human donor bodies. The position of the stents was verified by cone beam CT. The implanted ETs were harvested, embedded in resin and ground at 200 µm steps. Resulting images of the single steps were used to generate 3D models. The 3D models were then evaluated regarding position of the stent in the ET, its diameters, amount of squeezing, orientation of the axes and other parameters. Virtual reconstruction of the implanted ET was successful in all cases and revealed one incorrect stent placement. The cross-section increased for all metal stents in direction from the isthmus towards the pharyngeal orifice of the ET. Depending on the individual design of the metal stents (open or closed design), the shape varied also between different positions along a single stent. In contrast, the cross-section area and shape remained constant along the polymeric prototype. With the current investigation, insight into the behavior of different prototypes of ET stents was gained, which can help in defining the specifications for the intended ET stent.
Collapse
Affiliation(s)
- Lena Rosenbusch
- Department of Otorhinolaryngology, Hannover Medical School, Carl-Neuberg-Str. 1, 30625 Hannover, Germany
| | - Robert Schuon
- Department of Otorhinolaryngology, Hannover Medical School, Carl-Neuberg-Str. 1, 30625 Hannover, Germany
| | - Tamara Wilfling
- Department of Otorhinolaryngology, Hannover Medical School, Carl-Neuberg-Str. 1, 30625 Hannover, Germany
| | - Philipp Krüger
- Bess Pro GmbH, Gustav-Krone-Str. 7, 14167 Berlin, Germany
| | - Kerstin Lebahn
- Institute for Biomedical Engineering, Rostock University Medical Center, 18119 Rostock, Germany
| | | | - Olga Sahmel
- Institute for Biomedical Engineering, Rostock University Medical Center, 18119 Rostock, Germany
| | - Niels Grabow
- Institute for Biomedical Engineering, Rostock University Medical Center, 18119 Rostock, Germany
| | - Marko Schulze
- Institute of Anatomy, Rostock University Medical Center, 18057 Rostock, Germany
| | - Andreas Wree
- Institute of Anatomy, Rostock University Medical Center, 18057 Rostock, Germany
| | - Klaus-Peter Schmitz
- Institute for Biomedical Engineering, Rostock University Medical Center, 18119 Rostock, Germany
| | - Tobias Stein
- Bess Pro GmbH, Gustav-Krone-Str. 7, 14167 Berlin, Germany
| | - Thomas Lenarz
- Department of Otorhinolaryngology, Hannover Medical School, Carl-Neuberg-Str. 1, 30625 Hannover, Germany
- Cluster of Excellence Hearing4all, Hannover Medical School, Carl-Neuberg-Str. 1, 30625 Hannover, Germany
| | - Gerrit Paasche
- Department of Otorhinolaryngology, Hannover Medical School, Carl-Neuberg-Str. 1, 30625 Hannover, Germany
- Cluster of Excellence Hearing4all, Hannover Medical School, Carl-Neuberg-Str. 1, 30625 Hannover, Germany
| |
Collapse
|
8
|
Seetharaman S, Sankaranarayanan D, Gupta M. Magnesium-Based Temporary Implants: Potential, Current Status, Applications, and Challenges. J Funct Biomater 2023; 14:324. [PMID: 37367288 DOI: 10.3390/jfb14060324] [Citation(s) in RCA: 10] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2023] [Revised: 06/10/2023] [Accepted: 06/13/2023] [Indexed: 06/28/2023] Open
Abstract
Biomedical implants are important devices used for the repair or replacement of damaged or diseased tissues or organs. The success of implantation depends on various factors, such as mechanical properties, biocompatibility, and biodegradability of the materials used. Recently, magnesium (Mg)-based materials have emerged as a promising class of temporary implants due to their remarkable properties, such as strength, biocompatibility, biodegradability, and bioactivity. This review article aims to provide a comprehensive overview of current research works summarizing the above-mentioned properties of Mg-based materials for use as temporary implants. The key findings from in-vitro, in-vivo, and clinical trials are also discussed. Further, the potential applications of Mg-based implants and the applicable fabrication methods are also reviewed.
Collapse
Affiliation(s)
- Sankaranarayanan Seetharaman
- Department of Mechanical Engineering, College of Design and Engineering, National University of Singapore, 9 Engineering Drive 1, Block EA #07-08, Singapore 117575, Singapore
- Advanced Remanufacturing and Technology Centre (ARTC), Agency for Science, Technology and Research (A*STAR), 3 Cleantech Loop, #01/01 CleanTech Two, Singapore 637143, Singapore
| | - Dhivya Sankaranarayanan
- Department of Mechanical Engineering, College of Design and Engineering, National University of Singapore, 9 Engineering Drive 1, Block EA #07-08, Singapore 117575, Singapore
| | - Manoj Gupta
- Department of Mechanical Engineering, College of Design and Engineering, National University of Singapore, 9 Engineering Drive 1, Block EA #07-08, Singapore 117575, Singapore
| |
Collapse
|
9
|
Yao Q, Wu C, Yu X, Chen X, Pan G, Chen B. Current material engineering strategies to prevent catheter encrustation in urinary tracts. Mater Today Bio 2022; 16:100413. [PMID: 36118951 PMCID: PMC9474921 DOI: 10.1016/j.mtbio.2022.100413] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2022] [Revised: 08/25/2022] [Accepted: 08/26/2022] [Indexed: 11/19/2022] Open
Abstract
Catheters and ureteric stents have played a vital role in relieving urinary obstruction in many urological conditions. With the increasing use of urinary catheters/stents, catheter/stent-related complications such as infection and encrustation are also increasing because of their design defects. Long-term use of antibiotics and frequent replacement of catheters not only increase the economic burden on patients but also bring the pain of catheter replacement. This is unfavorable for patients with long indwelling catheters or stents but inconvenient to replace. In recent years, some promising technologies and mechanisms have been used to prevent infection and encrustation, mainly drug loading coatings, functional coatings, biodegradable polymers and metallic materials for urinary devices. Obvious effects in anti-encrustation and anti-infection experiments of the above strategies in vivo or in vitro have been conducted, which is very helpful for further clinical trials. This review mainly introduces catheter/stent technology and mechanisms in the past ten years to address the potential impact of anti-encrustation coating of catheter/stent materials for the prevention of encrustation and to analyze the progress made in this field.
Collapse
Affiliation(s)
- Qin Yao
- Department of Urology, Affiliated Hospital of Jiangsu University, 438 Jiefang Road, Zhenjiang, Jiangsu, 212001, PR China
| | - Chengshuai Wu
- Department of Urology, Affiliated Hospital of Jiangsu University, 438 Jiefang Road, Zhenjiang, Jiangsu, 212001, PR China
| | - Xiaoyu Yu
- Department of Urology, Affiliated Hospital of Jiangsu University, 438 Jiefang Road, Zhenjiang, Jiangsu, 212001, PR China
| | - Xu Chen
- Institute for Advanced Materials, School of Materials Science and Engineering, Jiangsu University, 304 Xuefu Road, Zhenjiang, Jiangsu, 212013, PR China
| | - Guoqing Pan
- Institute for Advanced Materials, School of Materials Science and Engineering, Jiangsu University, 304 Xuefu Road, Zhenjiang, Jiangsu, 212013, PR China
| | - Binghai Chen
- Department of Urology, Affiliated Hospital of Jiangsu University, 438 Jiefang Road, Zhenjiang, Jiangsu, 212001, PR China
| |
Collapse
|
10
|
Computational simulation of the flow dynamic field in a porous ureteric stent. Med Biol Eng Comput 2022; 60:2373-2387. [PMID: 35763188 PMCID: PMC9294020 DOI: 10.1007/s11517-022-02620-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2022] [Accepted: 06/15/2022] [Indexed: 11/04/2022]
Abstract
Ureteric stents are employed clinically to manage urinary obstructions or other pathological conditions. Stents made of porous and biodegradable materials have gained increasing interest, because of their excellent biocompatibility and the potential for overcoming the so-called ‘forgotten stent syndrome’. However, there is very limited characterisation of their flow dynamic performance. In this study, a CFD model of the occluded and unoccluded urinary tract was developed to investigate the urinary flow dynamics in the presence of a porous ureteric stent. With increasing the permeability of the porous material (i.e., from 10−18 to 10−10 m2) both the total mass flow rate through the ureter and the average fluid velocity within the stent increased. In the unoccluded ureter, the total mass flow rate increased of 7.7% when a porous stent with permeability of 10−10 m2 was employed instead of an unporous stent. Drainage performance further improved in the presence of a ureteral occlusion, with the porous stent resulting in 10.2% greater mass flow rate compared to the unporous stent. Findings from this study provide fundamental insights into the flow performance of porous ureteric stents, with potential utility in the development pipeline of these medical devices.
Collapse
|
11
|
Bonelli J, Ortega-Forte E, Rovira A, Bosch M, Torres O, Cuscó C, Rocas J, Ruiz J, Marchán V. Improving Photodynamic Therapy Anticancer Activity of a Mitochondria-Targeted Coumarin Photosensitizer Using a Polyurethane-Polyurea Hybrid Nanocarrier. Biomacromolecules 2022; 23:2900-2913. [PMID: 35695426 PMCID: PMC9277592 DOI: 10.1021/acs.biomac.2c00361] [Citation(s) in RCA: 15] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Integration of photosensitizers (PSs) within nanoscale delivery systems offers great potential for overcoming some of the "Achiles' heels" of photodynamic therapy (PDT). Herein, we have encapsulated a mitochondria-targeted coumarin PS into amphoteric polyurethane-polyurea hybrid nanocapsules (NCs) with the aim of developing novel nanoPDT agents. The synthesis of coumarin-loaded NCs involved the nanoemulsification of a suitable prepolymer in the presence of a PS without needing external surfactants, and the resulting small nanoparticles showed improved photostability compared with the free compound. Nanoencapsulation reduced dark cytotoxicity of the coumarin PS and significantly improved in vitro photoactivity with red light toward cancer cells, which resulted in higher phototherapeutic indexes compared to free PS. Importantly, this nanoformulation impaired tumoral growth of clinically relevant three-dimensional multicellular tumor spheroids. Mitochondrial photodamage along with reactive oxygen species (ROS) photogeneration was found to trigger autophagy and apoptotic cell death of cancer cells.
Collapse
Affiliation(s)
- Joaquín Bonelli
- Departament
de Química Inorgànica i Orgànica, Secció
de Química Orgànica, Institut de Biomedicina de la Universitat
de Barcelona (IBUB), Universitat de Barcelona
(UB), E-08028 Barcelona, Spain
- Nanobiotechnological
Polymers Division, Ecopol Tech, S.L., El Foix Business Park, Indústria
7, L’Arboç del Penedès, 43720 Tarragona, Spain
| | - Enrique Ortega-Forte
- Departamento
de Química Inorgánica, Universidad
de Murcia, Institute for Bio-Health Research of Murcia (IMIB-Arrixaca), E-30071 Murcia, Spain
| | - Anna Rovira
- Departament
de Química Inorgànica i Orgànica, Secció
de Química Orgànica, Institut de Biomedicina de la Universitat
de Barcelona (IBUB), Universitat de Barcelona
(UB), E-08028 Barcelona, Spain
| | - Manel Bosch
- Unitat
de Microscòpia Òptica Avançada, Centres Científics
i Tecnològics (CCiTUB), Universitat
de Barcelona (UB), E-08028 Barcelona, Spain
| | - Oriol Torres
- Nanobiotechnological
Polymers Division, Ecopol Tech, S.L., El Foix Business Park, Indústria
7, L’Arboç del Penedès, 43720 Tarragona, Spain
| | - Cristina Cuscó
- Nanobiotechnological
Polymers Division, Ecopol Tech, S.L., El Foix Business Park, Indústria
7, L’Arboç del Penedès, 43720 Tarragona, Spain
| | - Josep Rocas
- Nanobiotechnological
Polymers Division, Ecopol Tech, S.L., El Foix Business Park, Indústria
7, L’Arboç del Penedès, 43720 Tarragona, Spain
| | - José Ruiz
- Departamento
de Química Inorgánica, Universidad
de Murcia, Institute for Bio-Health Research of Murcia (IMIB-Arrixaca), E-30071 Murcia, Spain
| | - Vicente Marchán
- Departament
de Química Inorgànica i Orgànica, Secció
de Química Orgànica, Institut de Biomedicina de la Universitat
de Barcelona (IBUB), Universitat de Barcelona
(UB), E-08028 Barcelona, Spain
| |
Collapse
|
12
|
Abstract
PURPOSE OF REVIEW Ureteral stents are an invaluable tool for urologists but suffer from several drawbacks, including: limited durability due to stent encrustation, significant morbidity from bothersome urinary symptoms, pain and infection, risk of the forgotten stent and costly removal. This review highlights key advances in ureteral stent technology that seek to address these issues. RECENT FINDINGS Over the past 2 years clinical trials have brought ureteral stent technology aimed to reduce stent-associated morbidity closer to clinical application. Stent material and changes to stent design show promise in improving patient tolerability without increasing complications. Low-tech innovations such as magnetic and catheter snare removal may quickly reduce costs. Radical advances such as biodegradable stent materials remain in preclinical models but show promise for eliminating the need for stent removal. SUMMARY The ideal ureteral stent does not currently exist in clinical practice. This review highlights key studies that have advanced ureteral stent technology in the past 2 years.
Collapse
|
13
|
Domingues B, Pacheco M, Cruz JE, Carmagnola I, Teixeira‐Santos R, Laurenti M, Can F, Bohinc K, Moutinho F, Silva JM, Aroso IM, Lima E, Reis RL, Ciardelli G, Cauda V, Mergulhão FJ, Gálvez FS, Barros AA. Future Directions for Ureteral Stent Technology: From Bench to the Market. ADVANCED THERAPEUTICS 2021. [DOI: 10.1002/adtp.202100158] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Affiliation(s)
- Beatriz Domingues
- 3B's Research Group‐Research Institute on Biomaterials Biodegradables and Biomimetics University of Minho, Headquarters of the European Institute of Excellence on Tissue Engineering and Regenerative Medicine Avepark‐Parque Barco Guimarães 4805‐017 Portugal
- ICVS/3B's‐PT Government Associate Laboratory Braga/Guimarães 4805‐017 Portugal
| | - Margarida Pacheco
- 3B's Research Group‐Research Institute on Biomaterials Biodegradables and Biomimetics University of Minho, Headquarters of the European Institute of Excellence on Tissue Engineering and Regenerative Medicine Avepark‐Parque Barco Guimarães 4805‐017 Portugal
- ICVS/3B's‐PT Government Associate Laboratory Braga/Guimarães 4805‐017 Portugal
| | - Julia E. Cruz
- Endourology‐Endoscopy Department Minimally Invasive Surgery Centre Jesús Usón Cáceres 10071 Spain
| | - Irene Carmagnola
- Department of Mechanical and Aerospace Engineering Politecnico di Torino Turin 10129 Italy
- Polito BIOMedLAB Politecnico di Torino Turin 10129 Italy
| | - Rita Teixeira‐Santos
- LEPABE–Laboratory for Process Engineering Environment Biotechnology and Energy Faculty of Engineering University of Porto Porto 4200‐465 Portugal
| | - Marco Laurenti
- Department of Applied Science and Technology Politecnico di Torino Turin 10129 Italy
| | - Fusun Can
- Department of Medical Microbiology School of Medicine Koc University Istanbul 34450 Turkey
| | - Klemen Bohinc
- Faculty of Health Sciences University of Ljubljana Ljubljana 1000 Slovenia
| | - Fabíola Moutinho
- i3S‐Instituto de Investigação e Inovação em Saúde Universidade do Porto Porto 4200‐135 Portugal
- INEB‐Instituto de Engenharia Biomédica Universidade do Porto Porto 4200‐135 Portugal
| | - Joana M. Silva
- 3B's Research Group‐Research Institute on Biomaterials Biodegradables and Biomimetics University of Minho, Headquarters of the European Institute of Excellence on Tissue Engineering and Regenerative Medicine Avepark‐Parque Barco Guimarães 4805‐017 Portugal
- ICVS/3B's‐PT Government Associate Laboratory Braga/Guimarães 4805‐017 Portugal
| | - Ivo M. Aroso
- 3B's Research Group‐Research Institute on Biomaterials Biodegradables and Biomimetics University of Minho, Headquarters of the European Institute of Excellence on Tissue Engineering and Regenerative Medicine Avepark‐Parque Barco Guimarães 4805‐017 Portugal
- ICVS/3B's‐PT Government Associate Laboratory Braga/Guimarães 4805‐017 Portugal
| | - Estêvão Lima
- School of Health Sciences Life and Health Sciences Research Institute (ICVS) University of Minho Braga 4710‐057 Portugal
| | - Rui L. Reis
- 3B's Research Group‐Research Institute on Biomaterials Biodegradables and Biomimetics University of Minho, Headquarters of the European Institute of Excellence on Tissue Engineering and Regenerative Medicine Avepark‐Parque Barco Guimarães 4805‐017 Portugal
- ICVS/3B's‐PT Government Associate Laboratory Braga/Guimarães 4805‐017 Portugal
| | - Gianluca Ciardelli
- Department of Mechanical and Aerospace Engineering Politecnico di Torino Turin 10129 Italy
- Polito BIOMedLAB Politecnico di Torino Turin 10129 Italy
| | - Valentina Cauda
- Department of Applied Science and Technology Politecnico di Torino Turin 10129 Italy
| | - Filipe J. Mergulhão
- LEPABE–Laboratory for Process Engineering Environment Biotechnology and Energy Faculty of Engineering University of Porto Porto 4200‐465 Portugal
| | - Federico S. Gálvez
- Endourology‐Endoscopy Department Minimally Invasive Surgery Centre Jesús Usón Cáceres 10071 Spain
| | - Alexandre A. Barros
- 3B's Research Group‐Research Institute on Biomaterials Biodegradables and Biomimetics University of Minho, Headquarters of the European Institute of Excellence on Tissue Engineering and Regenerative Medicine Avepark‐Parque Barco Guimarães 4805‐017 Portugal
- ICVS/3B's‐PT Government Associate Laboratory Braga/Guimarães 4805‐017 Portugal
| |
Collapse
|
14
|
Lee J, Katz M, Shah O. Developments in Ureteral Stent Technology. Front Surg 2021; 8:764167. [PMID: 34869565 PMCID: PMC8637838 DOI: 10.3389/fsurg.2021.764167] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2021] [Accepted: 10/27/2021] [Indexed: 11/13/2022] Open
Abstract
Ureteral stents have been utilized for decades in maintaining ureteral patency, most commonly after ureteroscopy in the treatment of urolithiasis. Since their initial development, ureteral stents have had many technological advances that have allowed for better patient outcomes with improvements in comfort, durability, patency, encrustation resistance, biocompatibility, ease of insertion, migration, and biofilm development. Several new ureteral stents enter the market every year, each with their own touted benefits. It is essential to understand the different advantages for each ureteral stent to provide the best available care to patients when possible. The purpose of this review is to give a brief history of ureteral stent development and summarize the recent developments in ureteral stent designs. We aim to review the data supporting the clinical advantages of the latest ureteral stents available for use by urologists.
Collapse
Affiliation(s)
| | | | - Ojas Shah
- Department of Urology, Columbia University Medical Center, New York, NY, United States
| |
Collapse
|
15
|
Cui H, Zhang K, Gao C, Kang Y, Jiang H, He Y. Preparing and characterizing biodegradable materials for ureteral stents. POLYM ADVAN TECHNOL 2021. [DOI: 10.1002/pat.5455] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Affiliation(s)
- Haipo Cui
- Shanghai Institute for Minimally Invasive Therapy University of Shanghai for Science and Technology Shanghai China
| | - Kui Zhang
- Shanghai Institute for Minimally Invasive Therapy University of Shanghai for Science and Technology Shanghai China
| | - Chenguang Gao
- Shanghai Key Laboratory of Interventional Medical Devices & Equipment and Research & Engineering Academy of MicroPort Medical Group Co., Ltd Shanghai China
| | - Yahong Kang
- Shanghai Key Laboratory of Interventional Medical Devices & Equipment and Research & Engineering Academy of MicroPort Medical Group Co., Ltd Shanghai China
| | - Hongyan Jiang
- Shanghai Key Laboratory of Interventional Medical Devices & Equipment and Research & Engineering Academy of MicroPort Medical Group Co., Ltd Shanghai China
| | - Yingrong He
- Shanghai Institute for Minimally Invasive Therapy University of Shanghai for Science and Technology Shanghai China
| |
Collapse
|
16
|
Soria F, de La Cruz JE, Caballero-Romeu JP, Pamplona M, Pérez-Fentes D, Resel-Folskerma L, Sanchez-Margallo FM. Comparative assessment of biodegradable-antireflux heparine coated ureteral stent: animal model study. BMC Urol 2021; 21:32. [PMID: 33639905 PMCID: PMC7916282 DOI: 10.1186/s12894-021-00802-x] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2020] [Accepted: 02/18/2021] [Indexed: 02/08/2023] Open
Abstract
BACKGROUND Double J ureteral stents are widely used on urological patients to provide drainage of the upper urinary tract. Unfourtunately, ureteral stents are not free from complications, as bacterial colonization and require a second procedure for removal. The purpose of the current comparative experimental study is to evaluate a new heparin-coated biodegradable antireflux ureteral stent (BraidStent®-H) to prevent urinary bacterial colonization. METHODS A total of 24 female pigs were underwent determination of bacteriuria and nephrosonographic, endoscopic and contrast fluoroscopy assessment of the urinary tract. Afterward, were randomly assigned animals to Group-I, in which a 5Fr double-pigtail ureteral stent was placed for 6 weeks, or Group-II, in which a BraidStent®-H was placed. Follow-up assessments were performed at 1, 3, 6, 8, 12 weeks. The final follow-up includes the above methods and an exhaustive pathological study of the urinary tract was accomplished after 20 weeks. RESULTS Bacteriuria findings in the first 48 h were significant between groups at 6 h and 12 h. Asymptomatic bacteriuria does not reach 100% of the animals in Group-II until 48 h versus Group-I where it appears at 6 h. The weekly bacteriuria mean rate was 27.7% and 44.4% in Group I and II respectively, without statistical significance. In Group II there were no animals with vesicoureteral reflux, with statistical significance at 3 and 6 weeks with Group-I. The 91.2% of stents in Group-II were degraded between 3 and 6 weeks, without obstructive fragments. Distal ureteral peristalsis was maintained in 66.6-75% in Group-II at 1-6 weeks. CONCLUSIONS The heparin coating of BraidStent® allows an early decrease of bacterial colonization, but its effectiveness is low at the long term. Heparin coating did not affect scheduled degradation rate or size of stents fragments. BraidStent®-H avoids the side effects associated with current ureteral stents, thus should cause less discomfort to patients.
Collapse
Affiliation(s)
- Federico Soria
- Endoscopy-Endourology Department, Jesús Usón Minimally Invasive Surgery Centre Foundation, Carretera N-521, Km. 41.8, C.P.10071, Cáceres, Spain.
| | - Julia E de La Cruz
- Endoscopy-Endourology Department, Jesús Usón Minimally Invasive Surgery Centre Foundation, Cáceres, Spain
| | - Juan Pablo Caballero-Romeu
- Urology Department, Alicante University General Hospital, Alicante Institute for Health and Biomedical Research (ISABIAL Foundation), Alicante, Spain
| | - Manuel Pamplona
- Urology Department, 12 de Octubre University Hospital, Madrid, Spain
| | | | | | | |
Collapse
|