1
|
Wang LH, Cheng PT. Electrochemical Detector for Liquid Chromatography: Determining Minoxidil in Hair-Growth Pharmaceuticals. CURR ANAL CHEM 2019. [DOI: 10.2174/1573411014666180731120746] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Background:
The electrochemical behavior of minoxidil on gold (Au), Glassy Carbon (GCEs),
and Carbon Paste Electrodes (CPEs) was investigated in an aqueous supporting electrolyte (phosphate
buffer [pH 2.0-6.5], acetate buffer [pH 4.3], and Britton and Robinson buffer [pH 2.0-7.4]).
Methods:
For cyclic voltammetric measurements with suitable methodical parameters, CPEs catalyze
electrooxidation of minoxidil more efficiently than do other electrodes. Minoxidil was detected using
high-performance liquid chromatography with an electrochemical (carbon paste) detector (HPLCECD).
For direct current mode, with the current at a constant potential, and measurements with suitable
experimental parameters, a linear concentration from 0.02 to 2.6 mg L-1 was found. The detection
limit was approximately 20 ng m L-1.
Results:
The developed method detected minoxidil samples.
Conclusion:
Findings using HPLC-ECD and HPLC with an ultraviolet detector were comparable.
Collapse
Affiliation(s)
- Lai-Hao Wang
- Department of Medical Chemistry, Chia Nan University of Pharmacy and Science, 60 Erh-Jen Road, Section 1, Jen Te, Tainan 71743, Taiwan
| | - Pei-Tung Cheng
- Department of Medical Chemistry, Chia Nan University of Pharmacy and Science, 60 Erh-Jen Road, Section 1, Jen Te, Tainan 71743, Taiwan
| |
Collapse
|
2
|
de Jesus Guedes T, Pio dos Santos WT. Fast and Simple Electrochemical Analysis Kit for Quality Control of Narrow Therapeutic Index Drugs. ELECTROANAL 2018. [DOI: 10.1002/elan.201800108] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
Affiliation(s)
- Tiago de Jesus Guedes
- Departamento de Química; Universidade Federal dos Vales do Jequitinhonha e Mucuri, Campus JK; 39100-000 Diamantina, MG Brasil
| | - Wallans Torres Pio dos Santos
- Departamento de Farmácia; Universidade Federal dos Vales do Jequitinhonha e Mucuri, Campus JK; 39100-000 Diamantina, MG Brasil
| |
Collapse
|
3
|
Feng QM, Zhang Q, Shi CG, Xu JJ, Bao N, Gu HY. Using nanostructured conductive carbon tape modified with bismuth as the disposable working electrode for stripping analysis in paper-based analytical devices. Talanta 2013; 115:235-40. [DOI: 10.1016/j.talanta.2013.04.071] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2013] [Revised: 04/23/2013] [Accepted: 04/24/2013] [Indexed: 10/26/2022]
|