1
|
Bosio G, Destrempes F, Roy Cardinal MH, Cloutier G. Effect of rt-PA on Shear Wave Mechanical Assessment and Quantitative Ultrasound Properties of Blood Clot Kinetics In Vitro. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2024; 43:829-840. [PMID: 38205972 DOI: 10.1002/jum.16411] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/28/2023] [Revised: 12/21/2023] [Accepted: 12/26/2023] [Indexed: 01/12/2024]
Abstract
OBJECTIVE The consequences associated with blood clots are numerous and are responsible for many deaths worldwide. The assessment of treatment efficacy is necessary for patient follow-up and to detect treatment-resistant patients. The aim of this study was to characterize the effect of treatment on blood clots in vitro using quantitative ultrasound parameters. METHODS Blood from 10 pigs was collected to form three clots per pig in gelatin phantoms. Clots were subjected to 1) no treatment, 2) rt-PA (recombinant tissue plasminogen activator) treatment after 20 minutes of clotting, and 3) rt-PA treatment after 60 minutes of clotting. Clots were weighted before and after the experiment to assess the treatment effect by the mass loss. The clot kinetics was studied over 100 minutes using elastography (Young's modulus, shear wave dispersion, and shear wave attenuation). Homodyne K-distribution (HKD) parameters derived from speckle statistics were also studied during clot formation and dissolving (diffuse-to-total signal power ratio and intensity parameters). RESULTS Treated clots loosed significantly more mass than non-treated ones (P < .005). A significant increase in Young's modulus was observed over time (P < .001), and significant reductions were seen for treated clots at 20 or 60 minutes compared with untreated ones (P < .001). The shear wave dispersion differed for treated clots at 60 minutes versus no treatments (P < .001). The shear wave attenuation decreased over time (P < .001), and was different for clots treated at 20 minutes versus no treatments (P < .031). The HKD intensity parameter varied over time (P < .032), and was lower for clots treated at 20 and 60 minutes than those untreated (P < .001 and P < .02). CONCLUSION The effect of rt-PA treatment could be confirmed by a decrease in Young's modulus and HKD intensity parameter. The shear wave dispersion and shear wave attenuation were sensitive to late and early treatments, respectively. The Young's modulus, shear wave attenuation, and HKD intensity parameter varied over time despite treatment.
Collapse
Affiliation(s)
- Guillaume Bosio
- Laboratory of Biorheology and Medical Ultrasonics, University of Montreal Hospital Research Center (CRCHUM), Montreal, Quebec, Canada
- Institute of Biomedical Engineering, University of Montreal, Montreal, Quebec, Canada
| | - François Destrempes
- Laboratory of Biorheology and Medical Ultrasonics, University of Montreal Hospital Research Center (CRCHUM), Montreal, Quebec, Canada
| | - Marie-Hélène Roy Cardinal
- Laboratory of Biorheology and Medical Ultrasonics, University of Montreal Hospital Research Center (CRCHUM), Montreal, Quebec, Canada
| | - Guy Cloutier
- Laboratory of Biorheology and Medical Ultrasonics, University of Montreal Hospital Research Center (CRCHUM), Montreal, Quebec, Canada
- Institute of Biomedical Engineering, University of Montreal, Montreal, Quebec, Canada
- Department of Radiology, Radio-Oncology and Nuclear Medicine, University of Montreal, Montreal, Quebec, Canada
| |
Collapse
|
2
|
Bosio G, Destrempes F, Yazdani L, Roy Cardinal MH, Cloutier G. Resonance, Velocity, Dispersion, and Attenuation of Ultrasound-Induced Shear Wave Propagation in Blood Clot In Vitro Models. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2024; 43:535-551. [PMID: 38108551 DOI: 10.1002/jum.16387] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/23/2023] [Revised: 11/24/2023] [Accepted: 11/25/2023] [Indexed: 12/19/2023]
Abstract
OBJECTIVE Improve the characterization of mechanical properties of blood clots. Parameters derived from shear wave (SW) velocity and SW amplitude spectra were determined for gel phantoms and in vitro blood clots. METHODS Homogeneous phantoms and phantoms with gel or blood clot inclusions of different diameters and mechanical properties were analyzed. SW amplitude spectra were used to observe resonant peaks. Parameters derived from those resonant peaks were related to mimicked blood clot properties. Three regions of interest were tested to analyze where resonances occurred the most. For blood experiments, 20 samples from different pigs were analyzed over time during a 110-minute coagulation period using the Young modulus, SW frequency dispersion, and SW attenuation. RESULTS The mechanical resonance was manifested by an increase in the number of SW spectral peaks as the inclusion diameter was reduced (P < .001). In blood clot inclusions, the Young modulus increased over time during coagulation (P < .001). Descriptive spectral parameters (frequency peak, bandwidth, and distance between resonant peaks) were linearly correlated with clot elasticity values (P < .001) with R2 = .77 for the frequency peak, .60 for the bandwidth, and .48 for the distance between peaks. The SW dispersion and SW attenuation reflecting the viscous behavior of blood clots decreased over time (P < .001), mainly in the early stage of coagulation (first minutes). CONCLUSION The confined soft inclusion configuration favored SW mechanical resonances potentially challenging the computation of spectral-based parameters, such as the SW attenuation. The impact of resonances can be reduced by properly selecting the region of interest for data analysis.
Collapse
Affiliation(s)
- Guillaume Bosio
- Institute of Biomedical Engineering, University of Montreal, Montreal, Quebec, Canada
- Laboratory of Biorheology and Medical Ultrasonics, University of Montreal Hospital Research Center (CRCHUM), Montreal, Quebec, Canada
| | - François Destrempes
- Laboratory of Biorheology and Medical Ultrasonics, University of Montreal Hospital Research Center (CRCHUM), Montreal, Quebec, Canada
| | - Ladan Yazdani
- Institute of Biomedical Engineering, University of Montreal, Montreal, Quebec, Canada
- Laboratory of Biorheology and Medical Ultrasonics, University of Montreal Hospital Research Center (CRCHUM), Montreal, Quebec, Canada
| | - Marie-Hélène Roy Cardinal
- Laboratory of Biorheology and Medical Ultrasonics, University of Montreal Hospital Research Center (CRCHUM), Montreal, Quebec, Canada
| | - Guy Cloutier
- Institute of Biomedical Engineering, University of Montreal, Montreal, Quebec, Canada
- Laboratory of Biorheology and Medical Ultrasonics, University of Montreal Hospital Research Center (CRCHUM), Montreal, Quebec, Canada
- Department of Radiology, Radio-Oncology and Nuclear Medicine, University of Montreal, Montreal, Quebec, Canada
| |
Collapse
|
3
|
Santini P, Esposto G, Ainora ME, Lupascu A, Gasbarrini A, Zocco MA, Pola R. Ultrasound Elastography to Assess Age of Deep Vein Thrombosis: A Systematic Review. Diagnostics (Basel) 2023; 13:2075. [PMID: 37370970 DOI: 10.3390/diagnostics13122075] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2023] [Revised: 06/02/2023] [Accepted: 06/12/2023] [Indexed: 06/29/2023] Open
Abstract
BACKGROUND AND AIMS Deep-vein thrombosis (DVT) is a widely diffused condition, and its accurate staging has major clinical and therapeutic implications. Ultrasound elastography (UE) is a rapidly evolving imaging technique that allows quantification of elastic tissue properties and could play a crucial role in determining thrombus age. The aim of this review is to find clinical evidence regarding the application of UE in the evaluation of DVT and its usefulness in differentiating thrombosis age. METHODS A literature search of clinical studies was performed to identify the ability of UE of discriminate acute, subacute, and chronic DVT. Heterogeneity and publication bias were calculated. In accordance with the study protocol, a qualitative analysis of the evidence was planned. The results were summarized with a comprehensive summary table of study characteristics and baseline characteristics of participant patients. RESULTS Nine studies matched the predetermined eligibility requirements for this systematic review regarding the risk of bias; the greatest criticalities were found within the domains of patient selection and index test. Based on the quality assessment, two publications were excluded from the qualitative synthesis because of the presence of significant applicability concerns. Among the seven studies that were considered eligible for qualitative synthesis, four evaluated strain elastography and three evaluated shear-wave elastography. Despite significant differences concerning study design, thrombus age definitions, and patient characteristics, nearly all studies demonstrated an increase in thrombus stiffness according to DVT age. CONCLUSIONS UE could play a key role in routine ultrasound examination of DVT. The measurement of thrombus stiffness has a high biological plausibility and its use is supported by the finding of a correlation between the stiffness and the progression of the DVT age.
Collapse
Affiliation(s)
- Paolo Santini
- Section of Internal Medicine and Thromboembolic Diseases, Department of Medicine, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, Catholic University of Rome, 00168 Rome, Italy
| | - Giorgio Esposto
- Section of Internal Medicine and Thromboembolic Diseases, Department of Medicine, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, Catholic University of Rome, 00168 Rome, Italy
| | - Maria Elena Ainora
- Department of Internal Medicine and Gastroenterology, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, Catholic University of Rome, 00168 Rome, Italy
| | - Andrea Lupascu
- Section of Medical Angiology, Department of Medicine, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, Catholic University of Rome, 00168 Rome, Italy
| | - Antonio Gasbarrini
- Department of Internal Medicine and Gastroenterology, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, Catholic University of Rome, 00168 Rome, Italy
| | - Maria Assunta Zocco
- Department of Internal Medicine and Gastroenterology, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, Catholic University of Rome, 00168 Rome, Italy
| | - Roberto Pola
- Section of Internal Medicine and Thromboembolic Diseases, Department of Medicine, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, Catholic University of Rome, 00168 Rome, Italy
| |
Collapse
|
4
|
Duman E, Aslan A, Buz A, Sancak S, Aslan M, Kabaalioglu A, Fersahoglu AT, Okuroglu N, Onur E. Interobserver and Intraobserver Reliability in Sonoelastographic Assessment of Thyroid Nodules. Ultrasound Q 2023; 39:53-60. [PMID: 35943395 DOI: 10.1097/ruq.0000000000000616] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
BACKGROUND Thyroid ultrasonography is the first and perhaps most fundamental step for the radiological distinction of benign and malignant nodules. In this study, 2 radiologists reviewed the sonoelastographic and Doppler images of thyroid nodules and evaluated for the intraobserver and interobserver reliability. PURPOSE We aimed to determine confusing nodule identifiers and sonographic features differently defined by observers. METHODS A total of 157 nodules in 91 patients (male/female, 72:19) with ages ranging from 18 to 72 years old were included in the study. Ultrasonographic images and video clips of the nodules were obtained and presented to 2 reviewers unaware of the cytopathology results. Two observers defined the characteristics of the nodules based on previously determined criteria. Then, intraobserver and interobserver correlation coefficients were calculated for each subcategory. RESULTS In the grayscale ultrasonographic examination, varying degrees from low to high interobserver correlation coefficients were obtained for different subcategories (between κ = 0.359 and κ = 0.821). In color Doppler examination, we obtained medium correlation coefficients ( κ = 0.493 and κ = 0.553). On the other hand, there was a high correlation coefficient in tissue compression elastography ( κ = 0.617 and κ = 0.638).According to our study results, elastographic pattern, shape of the nodule, presence of echogenic foci, and pathological lymph nodes are better predictors to determine the malignant potential of thyroid nodule with higher interobserver correlation. Therefore, these criteria may be used primarily for the evaluation of thyroid nodules. The intraobserver correlation coefficient was higher in the practitioner with longer experience, suggesting the importance of professional practice period on the decision-making process.
Collapse
Affiliation(s)
- Emrah Duman
- Department of Radiology, Göztepe Training and Research Hospital, Faculty of Medicine, Istanbul Medeniyet University Medical School, İstanbul, Turkey
| | | | - Aysenur Buz
- Department of Radiology, Vezirkopru State Hospital, Samsun
| | - Seda Sancak
- Department of Internal Medicine, Endocrinology and Metabolism Disorders, University of Health Sciences, Fatih Sultan Mehmet Education and Research Hospital, Istanbul, Turkey
| | | | | | - Ayse Tuba Fersahoglu
- Department of General Surgery, University of Health Sciences, Fatih Sultan Mehmet Education and Research Hospital
| | - Nalan Okuroglu
- Department of Internal Medicine, University of Health Sciences, Fatih Sultan Mehmet Education and Research Hospital, Istanbul, Turkey
| | - Ender Onur
- Department of General Surgery, University of Health Sciences, Fatih Sultan Mehmet Education and Research Hospital
| |
Collapse
|
5
|
Abstract
Physicians have used palpation as a diagnostic examination to understand the elastic properties of pathology for a long time since they realized that tissue stiffness is closely related to its biological characteristics. US elastography provided new diagnostic information about elasticity comparing with the morphological feathers of traditional US, and thus expanded the scope of the application in clinic. US elastography is now widely used in the field of diagnosis and differential diagnosis of abnormality, evaluating the degree of fibrosis and assessment of treatment response for a range of diseases. The World Federation of Ultrasound Medicine and Biology divided elastographic techniques into strain elastography (SE), transient elastography and acoustic radiation force impulse (ARFI). The ARFI techniques can be further classified into point shear wave elastography (SWE), 2D SWE, and 3D SWE techniques. The SE measures the strain, while the shear wave-based techniques (including TE and ARFI techniques) measure the speed of shear waves in tissues. In this review, we discuss the various techniques separately based on their basic principles, clinical applications in various organs, and advantages and limitations and which might be most appropriate given that the majority of doctors have access to only one kind of machine.
Collapse
|
6
|
Durmaz F, Gultekin MA. Efficacy of Shear Wave Elastography in the Differentiation of Acute and Subacute Deep Venous Thrombosis. Ultrasound Q 2021; 37:168-172. [PMID: 34057916 DOI: 10.1097/ruq.0000000000000563] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
ABSTRACT It is important to know the age of clot formation to determine an appropriate treatment for deep vein thrombosis (DVT). The present study aims to differentiate between acute and subacute DVT using the shear wave elastography (SWE) technique. Patients with complaints no longer than 4 weeks and who were found to have early-stage (acute-subacute) thrombus on ultrasound (US) between January 2020 and May 2020 were included in the study. All of the patients underwent SWE using a Philips Healthcare EPIQ 5 Ultrasound System Inc. device with a high-resolution linear US probe (eL18-4, 22-2 MHz). Included in the study were 50 patients, including 23 with acute DVT and 27 with subacute DVT. Of the patients, 22 were women and 28 were men, and the mean age was 46.32 ± 11.33 years (range: 24-74 years). The mean SWE value was 2.63± 0.16 (2.39-2.96) in patients with acute DVT and 3.34± 0.31 (2.65-3.88) in patients with subacute DVT. The findings were statistically significant in the comparison of the 2 groups using an independent samples t test (P < 0.001). In the receiver operating characteristic analysis, the area under the curve was found to be 97.6%. When the cutoff value was taken as 2.85 according to the area under the curve, sensitivity was found to be 96.3%, and specificity was 91.3%. Thrombus stage plays a critical role in treatment decisions in DVT in the lower extremities. The present study reveals that the shear wave US elastography technique can be used to discriminate between acute and subacute DVT.
Collapse
Affiliation(s)
- Fatma Durmaz
- Department of Radiology, Faculty of Medicine, Van Yuzuncu Yil University, Van
| | - Mehmet Ali Gultekin
- Department of Radiology, Faculty of Medicine, Bezmialem Vakif University, Istanbul, Turkey
| |
Collapse
|
7
|
Mumoli N, Mastroiacovo D, Giorgi-Pierfranceschi M, Pesavento R, Mochi M, Cei M, Pomero F, Mazzone A, Vitale J, Ageno W, Dentali F. Ultrasound elastography is useful to distinguish acute and chronic deep vein thrombosis. J Thromb Haemost 2018; 16:2482-2491. [PMID: 30225971 DOI: 10.1111/jth.14297] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2018] [Indexed: 12/18/2022]
Abstract
Essentials Ultrasound elastography uses tissue deformation to assess the relative quantification of its elasticity. Compression and duplex ultrasonography may be unable to correctly determine the thrombus age. Ultrasound elastography may be useful to distinguish between acute and chronic deep vein thrombosis. The exact determination of the thrombus age could have both therapeutic and prognostic implications. BACKGROUND: Background Ultrasound elastography (UE) imaging is a novel sonographic technique that is commonly employed for relative quantification of tissue elasticity. Its applicability to venous thromboembolic events has not yet been fully established; in particular, it is unclear whether this technique may be useful in determining the age of deep vein thrombosis (DVT). Thus, the aim of this study was to assess the role of UE in distinguishing acute from chronic DVT. Methods Consecutive patients with a first unprovoked acute and chronic (3 months old) DVT of the lower limbs were analyzed. Patients with recurrent DVT or with a suspected recurrence were excluded. The mean elasticity index (EI) values of acute and chronic popliteal and femoral vein thrombosis were compared. The accuracy of the EI in distinguishing acute from chronic DVT was also assessed by measuring the sensitivity, specificity, positive and negative predictive values, and likelihood ratios. Results One-hundred and forty-nine patients (mean age 63.9 years, standard deviation 13.6; 73 males) with acute and chronic DVT were included. The mean EI of acute femoral DVT was higher than that of chronic femoral DVT (5.09 versus 2.46), and the mean EI of acute popliteal DVT was higher than that of chronic popliteal DVT (4.96 versus 2.48). An EI value of > 4 resulted in a sensitivity of 98.9% (95% confidence interval [CI] 93.3-99.9), a specificity of 99.1% (95% CI 94.8-99.9), a positive predictive value of 91.1% (95% CI 77.9-97.1), a negative predictive value of 98.6% (95% CI 91.3-99.9), a positive likelihood ratio of 13.23 (95% CI 93-653) and a negative likelihood ratio of 0.001 (95% CI 0.008-0.05) for acute DVT. Conclusions UE appears to be a promising technique for distinguishing between acute and chronic DVT. Larger prospective studies are warranted to confirm our preliminary findings.
Collapse
Affiliation(s)
- N Mumoli
- Department of Internal Medicine, Livorno Hospital, Livorno, Italy
| | - D Mastroiacovo
- Department of Internal Medicine, Livorno Hospital, Livorno, Italy
| | | | - R Pesavento
- Department of Internal Medicine, Livorno Hospital, Livorno, Italy
| | - M Mochi
- General Electric Healthcare, Milano, Italy
| | - M Cei
- Department of Internal Medicine, Livorno Hospital, Livorno, Italy
| | - F Pomero
- Department of Internal Medicine, Livorno Hospital, Livorno, Italy
| | - A Mazzone
- Department of Internal Medicine, Livorno Hospital, Livorno, Italy
| | - J Vitale
- Department of Clinical and Experimental Medicine, Insubria University, Varese, Italy
| | - W Ageno
- Department of Clinical and Experimental Medicine, Insubria University, Varese, Italy
| | - F Dentali
- Department of Clinical and Experimental Medicine, Insubria University, Varese, Italy
| |
Collapse
|