1
|
Erturk-Avunduk AT, Delikan E, Cengiz-Yanardag E, Karakaya I. Effect of whitening concepts on surface roughness and optical characteristics of resin-based composites: An AFM study. Microsc Res Tech 2024; 87:214-228. [PMID: 37724605 DOI: 10.1002/jemt.24424] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2023] [Revised: 08/30/2023] [Accepted: 09/06/2023] [Indexed: 09/21/2023]
Abstract
The aim of this study was to evaluate the effects of various whitening agents on the surface roughness and optical characteristics of different types of resin composite restorations. Fifty specimens were prepared for each resin [G-aenial Posterior (GP), SonicFill-2 (SF), Solidex (SDX), and Nova Compo HF (NC)]. Following baseline color and surface roughness (Ra) measurements, the specimens were randomly divided into 5 groups (n = 10/group) according to whitening concepts: control (distilled water), in-office bleaching [OB-(Opalescence Boost)], at-home bleaching [HB-(Opalescence PF)], whitening toothpaste [WT-(Signal White Now)], and whitening mouthwash [WM-(Listerine Advanced White)]. ∆E00 , ∆TP00 , and ∆WID values were calculated before and after the whitening procedure with a spectrophotometer using the CIEDE2000 formula. Surface roughness measurements were repeated. The surface topography was determined using atomic force microscopy. Two- and three-way analyses of variance and Tukey's post-hoc test were performed, with p < 0.05 regarded as indicative of significance. No significant differences were detected among the resin composite materials in terms of the ΔE00 values (p > 0.05). Color change of all resin materials was above the AT threshold (>1.8) and the PT threshold (>0.8). All restorative materials presented acceptable (AT<2.62) TP00 values. Solidex specimens demonstrated the lowest WID values compared to the other composites. There were significant differences among the whitening procedures with respect to ΔE00 , ΔTP00 , and WID values (p < 0.001). SF/WT combination showed the highest and clinically unacceptable ΔE00 values. The highest roughness values were observed in the SDX specimens and the combination of SDX/OB. The effect of whitening agents on the optical characteristics and surface roughness of restorative materials depends on the type of material, agent, and time. RESEARCH HIGHLIGHTS: Clinicians should be aware that long-term use of over-the-counter products due to the abrasive effects of their ingredients and repeated bleaching session applications may affect the color stability and surface roughness of resin composites.
Collapse
Affiliation(s)
| | - Ebru Delikan
- Department of Pediatric Dentistry, Faculty of Dentistry, Nuh Naci Yazgan University, Kayseri, Turkey
| | - Esra Cengiz-Yanardag
- Department of Restorative Dentistry, Faculty of Dentistry, Mersin University, Mersin, Turkey
| | - Izgen Karakaya
- Department of Restorative Dentistry, Faculty of Dentistry, European University of Lefke, Mersin10, Turkey
| |
Collapse
|
2
|
Paolone G, Formiga S, De Palma F, Abbruzzese L, Chirico L, Scolavino S, Goracci C, Cantatore G, Vichi A. Color stability of resin-based composites: Staining procedures with liquids-A narrative review. J ESTHET RESTOR DENT 2022; 34:865-887. [PMID: 35396818 DOI: 10.1111/jerd.12912] [Citation(s) in RCA: 24] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2021] [Revised: 01/30/2022] [Accepted: 03/24/2022] [Indexed: 12/12/2022]
Abstract
OBJECTIVE The objective of this study was to review the experimental staining procedures performed in in-vitro studies for evaluating color stability of resin-based composites used for direct restorations. OVERVIEW A review was performed with the purpose to identify in vitro procedures carried out to establish staining and color stability of resin-based composites used for direct restorations. A literature search was performed on four online databases (PubMed, Scopus, Embase and Web of Science) for articles published from January 1st 2001 till March 20th 2021, using a combination of free words and Medical Subject Headings (MESH) terms: "Composite Resins" AND "Color Stability" OR "Staining." Two reviewers screened titles and/or abstracts of 1728 unique studies. In total, 208 studies were selected for full-text reading, from which 178 were included in the review. The assessed variables were specimen dimensions, shape, and surface finishing; time before immersion; staining media type, dwell time, temperature and renewal interval; type of composite; color and translucency assessment parameters and measuring system. One hundred and seventy-eight articles analyzed color stability with staining liquids. Coffee was the most used staining medium (n = 102), followed by tea (n = 61), and red wine (n = 55). A disc-shaped specimen was used in most studies (n = 170) with a 2 mm thickness (n = 116). Spectrophotometers were the most used color assessment devices (n = 154), followed by colorimeters (n = 17). Color differences were quantified with ΔE (n = 154), ΔE00 (n = 23). Acceptability and or perceptibility thresholds were also taken into consideration (n = 126). CONCLUSIONS The large variety of staining procedure suggests the need for standardization. CLINICAL SIGNIFICANCE Aesthetic failure due to discoloration is a relevant clinical problem. Evaluating benefits and drawbacks of resin based composites artificial staining procedures will improve to predict materials clinical performances.
Collapse
Affiliation(s)
- Gaetano Paolone
- Dental School, IRCCS San Raffaele Hospital, Vita-Salute University, Milan, Italy
| | - Sara Formiga
- Dental School, IRCCS San Raffaele Hospital, Vita-Salute University, Milan, Italy
| | - Francesca De Palma
- Dental School, IRCCS San Raffaele Hospital, Vita-Salute University, Milan, Italy
| | - Luca Abbruzzese
- Dental School, IRCCS San Raffaele Hospital, Vita-Salute University, Milan, Italy
| | - Luca Chirico
- Dental School, IRCCS San Raffaele Hospital, Vita-Salute University, Milan, Italy
| | | | - Cecilia Goracci
- Department of Medical Biotechnologies, University of Siena, Siena, Italy
| | - Giuseppe Cantatore
- Dental School, IRCCS San Raffaele Hospital, Vita-Salute University, Milan, Italy
| | | |
Collapse
|
3
|
Morais Sampaio GAD, Rangel Peixoto L, Vasconcelos Neves GD, Nascimento Barbosa DD. Effect of mouthwashes on color stability of composite resins: A systematic review. J Prosthet Dent 2020; 126:386-392. [PMID: 32891404 DOI: 10.1016/j.prosdent.2020.08.001] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2019] [Revised: 08/04/2020] [Accepted: 08/04/2020] [Indexed: 12/15/2022]
Abstract
STATEMENT OF PROBLEM Some mouthwash ingredients may stain composite resin restorations, but how the daily use of mouthwashes might affect the color of composite resin restorations is unclear. PURPOSE The purpose of this systematic review was to investigate whether mouthwashes can affect the color of direct composite resin restorations. MATERIAL AND METHODS Bibliographical searches were carried out in PubMed, Scopus, Cochrane Library, and Web of Science databases, with no restriction on language, country, or date of publication. Studies addressing the effect of mouthwashes on the color stability of composite resins were included. The level of evidence of selected articles was determined by a qualitative scoring system and classified as high, moderate, or low. RESULTS Based on the search strategy, a total of 129 articles were retrieved; of which, 15 met the inclusion criteria. Most of the studies (93%) were classified as having a high level of evidence. Filtek Z350 and Listerine were the most frequently tested composite resin and mouthwash. Eight studies used distilled water as a control, 5 used artificial saliva, 1 study used an alcohol solution, and 1 did not include a control group. The composite resins were continuously immersed in the mouthwashes in 9 studies or in daily cycles in 6 studies. All studies tested the color change of the specimens after immersion in the mouthwashes. The color change was considered clinically acceptable (ΔE≤2.7) for all test mouthwashes in 10 studies. CONCLUSIONS Most studies reported that mouthwashes did not cause a clinically unacceptable color change in composite resins.
Collapse
Affiliation(s)
| | - Larissa Rangel Peixoto
- Professor, Department of Dentistry, State University of Paraíba (UEPB), Araruna, Paraíba, Brazil
| | | | | |
Collapse
|
4
|
El Gezawi M, Kaisarly D, Al-Saleh H, ArRejaie A, Al-Harbi F, Kunzelmann KH. Degradation Potential of Bulk Versus Incrementally Applied and Indirect Composites: Color, Microhardness, and Surface Deterioration. Oper Dent 2018; 41:e195-e208. [PMID: 27820694 DOI: 10.2341/15-195-l] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
This study investigated the color stability and microhardness of five composites exposed to four beverages with different pH values. Composite discs were produced (n=10); Filtek Z250 (3M ESPE) and Filtek P90 (3M ESPE) were applied in two layers (2 mm, 20 seconds), and Tetric N-Ceram Bulk Fill (TetricBF, Ivoclar Vivadent) and SonicFill (Kerr) were applied in bulk (4 mm) and then light cured (40 seconds, Ortholux-LED, 1600 mW/cm2). Indirect composite Sinfony (3M ESPE) was applied in two layers (2 mm) and cured (Visio system, 3M ESPE). The specimens were polished and tested for color stability; ΔE was calculated using spectrophotometer readings. Vickers microhardness (50 g, dwell time=45 seconds) was assessed on the top and bottom surfaces at baseline, 40 days of storage, subsequent repolishing, and 60 days of immersion in distilled water (pH=7.0), Coca-Cola (pH=2.3), orange juice (pH=3.75), or anise (pH=8.5) using scanning electron microscopy (SEM). The materials had similar ΔE values (40 days, p>0.05), but TetricBF had a significantly greater ΔE than P90 or SF (40 days). The ΔE was less for P90 and TetricBF than for Z250, SonicFill, and Sinfony (60 days). Repolishing and further immersion significantly affected the ΔE (p<0.05) except for P90. All composites had significantly different top vs bottom baseline microhardnesses. This was insignificant for the Z250/water, P90/orange juice (40 days), and Sinfony groups (40 and 60 days). Immersion produced variable time-dependent deterioration of microhardness in all groups. Multivariate repeated measures analysis of variance with post hoc Bonferroni tests were used to compare the results. ΔE and microhardness changes were significantly inversely correlated at 40 days, but this relationship was insignificant at 60 days (Pearson test). SEM showed degradation (40 days) that worsened (60 days). Bulk-fill composites differ regarding color-stability and top-to-bottom microhardness changes compared with those of other composites. P90 showed better surface degradation resistance. In conclusion, bulk-fill composites are not promising alternatives to incremental and indirect composites regarding biodegradation.
Collapse
|
5
|
PLASTER SC, PEIXOTO LM, GUEDES APA, SILVA DN, CASTRO MCC. Efeito de diferentes fotopolimerizadores e meio de imersão na rugosidade e na cor de um compósito nanoparticulado. REVISTA DE ODONTOLOGIA DA UNESP 2016. [DOI: 10.1590/1807-2577.09916] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
Resumo Introdução O consumo excessivo de refrigerantes parece alterar as propriedades dos compósitos e essa alteração pode estar relacionada à unidade fotopolimerizadora. Objetivo Avaliar a alteração da rugosidade superficial (ΔR) e da cor (ΔE) de um compósito polimerizado por diferentes fotopolimerizadores, imerso em água destilada ou Coca-Cola®. Metodologia Sessenta amostras da resina nanoparticulada (FiltekMR Z350 XT, 3M) foram distribuídas de acordo com as diferentes unidades de fotopolimerização: a) luz halógena de quartzo-tungstênio-halogênio (QTH); b) Luz de Emissão Diodo - LED 1 com ponteira de polímero; c) LED 2 com ponteira de fibra ótica. Metade de cada grupo (n=10) foi mantida em água destilada ou imersa em Coca-Cola® 2×/dia por 20 minutos, durante 14 dias. Os dados foram submetidos aos testes Mann-Whitney e Kruskal-Wallis (p≤0,05). Resultado A ΔR não foi significante entre os grupos: em água: QTH = 0,006; LED 1 = 0,019; LED 2 = 0,010 (p=0,33); em refrigerante: QTH = 0,021; LED 1= 0,011; LED 2 = 0,030 (p=0,86). A ΔE não foi significativa entre os fotopolimerizadores: em água: QTH = 1,40; LED 1 = 1,80; LED 2 = 1,60 (p=0,31); em refrigerante: QTH = 2,51; LED 1= 1,91; LED 2 = 2,61 (p=0,41), mas foi significante comparando os meios de imersão (p=0,01), exceto para LED 1 (p=0,54). Conclusão As unidades fotopolimerizadoras não interferiram na rugosidade superficial e na cor da resina composta nanoparticulada. Os mergulhos diários em refrigerante não alteraram a lisura, mas alteraram a cor de modo visualmente perceptível, mas clinicamente aceitável, conforme os parâmetros da literatura científica.
Collapse
|
6
|
Effects of nanofillers on mechanical properties of fiber-reinforced composites polymerized with light-curing and additional postcuring. J Appl Biomater Funct Mater 2015; 13:e296-9. [PMID: 26108426 DOI: 10.5301/jabfm.5000226] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 01/19/2015] [Indexed: 12/12/2022] Open
Abstract
BACKGROUND The purpose of the present study was to evaluate the effect of nanofillers on the mechanical properties of 2 sizes (diameters 0.6 and 0.9 mm) of conventional and nanofilled fiber-reinforced composites (FRCs) polymerized with conventional light-curing and additional postcuring. METHODS The FRCs samples were divided into 8 groups (10 specimens each). Conventional FRCs with glass fibers preimpregnated with polymethyl methacrylate (groups 1, 2, 3 and 4) and FRCs with impregnating solution containing 32% nanofilled resin (groups 5, 6, 7 and 8) were tested in 2 different sections (0.6 and 0.9 mm in diameter). Two different polymerizations were analyzed: hand light-curing for 40 seconds with an halogen light, and additional postcuring for 25 minutes in a light-curing oven. Each sample was evaluated with a 3-point bending test on a universal testing machine, after 48 hours of dry storage. All of the data were statistically analyzed. RESULTS After oven postcuring, nanofilled FRCs exhibited significantly higher load values than conventional FRCs. No significant differences were found when comparing conventional and nanofilled FRCs after hand light-curing. Moreover, 0.6-mm FRCs showed significantly lower load values than 0.9-mm FRCs, both for conventional and nanofilled FRCs. CONCLUSIONS Nanofilled FRCs showed higher load values after additional oven postcuring.
Collapse
|