1
|
Brookhart A, Arora M, McCullagh M, Wilson ID, Plumb RS, Vissers JP, Tanna N. Understanding mobile phase buffer composition and chemical structure effects on electrospray ionization mass spectrometry response. J Chromatogr A 2023; 1696:463966. [PMID: 37054638 DOI: 10.1016/j.chroma.2023.463966] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2023] [Revised: 04/01/2023] [Accepted: 04/03/2023] [Indexed: 04/15/2023]
Abstract
Mobile phase selection is of critical importance in liquid chromatography - mass spectrometry (LC-MS) based studies, since it affects retention, chromatographic selectivity, ionization, limits of detection and quantification, and linear dynamic range. Generalized LC-MS mobile phase selection criteria, suitable for a broad class of chemical compounds, do not exist thus far. Here we have performed a large-scale qualitative assessment of the effect of solvent composition used for reversed-phase LC separations on electrospray ionization (ESI) response for 240 small molecular weight drugs, representing various chemical compound classes. Of these 240 analytes 224 were detectable using ESI. The main chemical structural features affecting ESI response were found to all be surface area or surface charge-related. Mobile phase composition was found to be less differentiating, although for some compounds a pH effect was noted. Unsurprisingly, chemical structure was found to be the dominant factor for ESI response for the majority of the investigated analytes, representing about 85% of the replicating detectable complement of the sample data set. A weak correlation between ESI response and structure complexity was observed. Solvents based on isopropanol, and those containing phosphoric or di- and trifluoracetic acids, performed relatively poorly in terms of chromatographic or ESI response, whilst the best performing 'generic' LC solvents were based on methanol, acetonitrile using formic acid and ammonium acetate as buffer components, consistent with current practice in many laboratories.
Collapse
Affiliation(s)
- Allison Brookhart
- Department of Biochemistry and Molecular Biology, University of Massachusetts Amherst, MA
| | - Mahika Arora
- Manning College of Information and Computer Sciences, University of Massachusetts Amherst, MA
| | | | - Ian D Wilson
- Computational & Systems Medicine, Department of Metabolism, Digestion and Reproduction, Imperial College, United Kingdom
| | | | | | | |
Collapse
|
2
|
Dugo P, Mondello L, Sebastiani E, Ottanà R, Errante G, Dugo G. IDENTIFICATION OF MINOR OXYGEN HETEROCYCLIC COMPOUNDS OF CITRUS ESSENTIAL OILS BY LIQUID CHROMATOGRAPHY-ATMOSPHERIC PRESSURE CHEMICAL IONISATION MASS SPECTROMETRY. J LIQ CHROMATOGR R T 2007. [DOI: 10.1081/jlc-100102073] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Affiliation(s)
- P. Dugo
- a Dipartimento di Chimica Organica e Biologica , Facoltà di Scienze, Università di Messina , Salita Sperone, Messina , 98166 , Italy
| | - L. Mondello
- b Dipartimento Farmaco-Chimico , Facoltà di Farmacia, Università di Messina Viale Annunziata , Messina , 98168 , Italy
| | | | - R. Ottanà
- b Dipartimento Farmaco-Chimico , Facoltà di Farmacia, Università di Messina Viale Annunziata , Messina , 98168 , Italy
| | - G. Errante
- b Dipartimento Farmaco-Chimico , Facoltà di Farmacia, Università di Messina Viale Annunziata , Messina , 98168 , Italy
| | - G. Dugo
- b Dipartimento Farmaco-Chimico , Facoltà di Farmacia, Università di Messina Viale Annunziata , Messina , 98168 , Italy
| |
Collapse
|
3
|
Affiliation(s)
- S D Richardson
- National Exposure Research Laboratory, U.S. Environmental Protection Agency, Athens, Georgia 30605, USA
| |
Collapse
|
4
|
Dugo P, Mondello L, Dugo L, Stancanelli R, Dugo G. LC-MS for the identification of oxygen heterocyclic compounds in citrus essential oils. J Pharm Biomed Anal 2000; 24:147-54. [PMID: 11108548 DOI: 10.1016/s0731-7085(00)00400-3] [Citation(s) in RCA: 123] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
The oxygen heterocyclic compounds (coumarins, psoralens and polymethoxylated flavones) present in the nonvolatile residue of the essential oils of Mandarin, Sweet Orange, Bitter Orange, Bergamot and Grapefruit were analysed with an HPLC/API/MS system equipped with an APcI probe in positive mode. The use of hyphenated techniques, such as LC/MS provides a great information about the content and nature of constituents of natural complex matrices, such as essential oils. In this work, MS spectra were recorded at different voltages, to obtain structural information in addition to molecular weight information. The different response of the compounds identified has been also evaluated. The method allowed the confirmation of the identification of the main components of the fraction, previously reported for the different oils. MS characteristics of coumarins, psoralens and polymethoxylated flavones with different substitution patterns were determined on the basis of the response obtained with the APcI interface. Interface parameters were optimised to obtain a contemporaneous response for all the three classes of components.
Collapse
Affiliation(s)
- P Dugo
- Dipartimento di Chimica Organica e Biologica, Facoltà di Scienze, Università di Messina, Italy.
| | | | | | | | | |
Collapse
|
5
|
Van Bocxlaer JF, Clauwaert KM, Lambert WE, Deforce DL, Van den Eeckhout EG, De Leenheer AP. Liquid chromatography-mass spectrometry in forensic toxicology. MASS SPECTROMETRY REVIEWS 2000; 19:165-214. [PMID: 10986692 DOI: 10.1002/1098-2787(200007)19:4<165::aid-mas1>3.0.co;2-y] [Citation(s) in RCA: 71] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
Liquid chromatography-mass spectrometry has evolved from a topic of mainly research interest into a routinely usable tool in various application fields. With the advent of new ionization approaches, especially atmospheric pressure, the technique has established itself firmly in many areas of research. Although many applications prove that LC-MS is a valuable complementary analytical tool to GC-MS and has the potential to largely extend the application field of mass spectrometry to hitherto "MS-phobic" molecules, we must recognize that the use of LC-MS in forensic toxicology remains relatively rare. This rarity is all the more surprising because forensic toxicologists find themselves often confronted with the daunting task of actually searching for evidence materials on a scientific basis without any indication of the direction in which to search. Through the years, mass spectrometry, mainly in the GC-MS form, has gained a leading role in the way such quandaries are tackled. The advent of robust, bioanalytically compatible combinations of liquid chromatographic separation with mass spectrometric detection really opens new perspectives in terms of mass spectrometric identification of difficult molecules (e.g., polar metabolites) or biopolymers with toxicological relevance, high throughput, and versatility. Of course, analytical toxicologists are generally mass spectrometry users rather than mass spectrometrists, and this difference certainly explains the slow start of LC-MS in this field. Nevertheless, some valuable applications have been published, and it seems that the introduction of the more universal atmospheric pressure ionization interfaces really has boosted interests. This review presents an overview of what has been realized in forensic toxicological LC-MS. After a short introduction into LC-MS interfacing operational characteristics (or limitations), it covers applications that range from illicit drugs to often abused prescription medicines and some natural poisons. As such, we hope it can act as an appetizer to those involved in forensic toxicology but still hesitating to invest in LC-MS.
Collapse
|
6
|
Bogusz MJ. Hyphenated liquid chromatographic techniques in forensic toxicology. JOURNAL OF CHROMATOGRAPHY. B, BIOMEDICAL SCIENCES AND APPLICATIONS 1999; 733:65-91. [PMID: 10572975 DOI: 10.1016/s0378-4347(98)00520-9] [Citation(s) in RCA: 42] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
Abstract
The prerequisite of applicability of hyphenated methods in forensic analysis is the achievement of a stage of "final maturity". In the field of liquid chromatography, HPLC coupled with diode array detection (DAD) seems to fulfill this criterion, whilst the combination with atmospheric pressure ionization mass spectrometry (HPLC-API-MS) is still in a development stage. HPLC-DAD is broadly used as identification tool in forensic and in emergency toxicology. Two main approaches were observed; development of retention index scales for intra-laboratory exchange of data and establishing of databases only for intra-laboratory use. Using these approaches, several databases were established for toxicological relevant substances (illicit and therapeutic drugs and their metabolites, environmental poisons etc.) in biological fluids. Also, complete HPLC-DAD identification systems are commercially available. Further possibility of progress depends on the on-line combination ("triple hyphenation") with other detection methods, preferably API-MS. HPLC-API-MS, both in electrospray (ESI) and atmospheric pressure chemical ionization (APCI) options, underwent dramatic development in the last decade and is reaching its final shape. The method was broadly applied for various groups of toxicologically relevant substances, a lot of them unaccessible for other techniques, including GC-MS. Particularly important was application of HPLC-API-MS for detection and quantitation of active, polar metabolites of various drugs and for analysis of macromolecules. APCI seems to be more useful for analysis of less polar compounds, whereas ESI is particularly valuable for determination of polar, large molecules (e.g., toxic peptides, polar metabolites etc.) Up to now, HPLC-API-MS has been mainly applied for dedicated analyses, but the introduction of APCI or ESI in systematic toxicological screening may be expected in the near future.
Collapse
Affiliation(s)
- M J Bogusz
- Institute of Forensic Medicine, Aachen University of Technology, Germany.
| |
Collapse
|
7
|
Ryan D, Robards K, Prenzler P, Antolovich M. Applications of mass spectrometry to plant phenols. Trends Analyt Chem 1999. [DOI: 10.1016/s0165-9936(98)00118-6] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
|
8
|
Pichini S, Altieri I, Pellegrini M, Zuccaro P, Pacifici R. The role of liquid chromatography-mass spectrometry in the determination of heroin and related opioids in biological fluids. MASS SPECTROMETRY REVIEWS 1999; 18:119-130. [PMID: 10517024 DOI: 10.1002/(sici)1098-2787(1999)18:2<119::aid-mas2>3.0.co;2-z] [Citation(s) in RCA: 22] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
The opioid most commonly sold in the illicit market is heroin. This substance, classified as an analgesic narcotic drug, has an extremely short half-life, and it is rapidly metabolized to 6-monoacetyl-morphine and further to morphine. Morphine is principally metabolized by conjugation to morphine-3 and morphine-6 glucuronides. Morphine itself is a potent analgesic that is frequently used in the pharmacological intervention of cancer pain. The toxicological and clinical evaluation of heroin and morphine have stimulated pharmacokinetic studies in human and animal models. Although a number of methods exist to determine opiates and their metabolites, liquid chromatography (LC) appears to be the technique that can separate without any pretreatment the lipophilic and the hydrophilic analytes of the complete metabolic profile of heroin and/or morphine. Moreover, mass spectrometry (MS) used as a detector for liquid chromatography is unique, because it offers universality and selectivity. Furthermore, efforts have been made to develop LC/MS interfaces that could overcome the previous problem of poor sensitivity. For this reason, in recent years LC combined with MS has been applied to the analysis of opiates--parent drugs and metabolites--in biological fluids. This article reviews the existing literature on the determination, using liquid chromatography coupled to mass spectrometry, of opiate metabolites found in different biological matrices after the administration of the parent compounds.
Collapse
Affiliation(s)
- S Pichini
- Clinical Biochemistry Department, Istituto Superiore di Sanità, Rome, Italy
| | | | | | | | | |
Collapse
|
9
|
Careri M, Mangia A, Musci M. Overview of the applications of liquid chromatography–mass spectrometry interfacing systems in food analysis: naturally occurring substances in food. J Chromatogr A 1998. [DOI: 10.1016/s0021-9673(97)00654-7] [Citation(s) in RCA: 71] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
10
|
|
11
|
Application of liquid chromatography-atmospheric pressure ionization mass spectrometry in natural product analysis evaluation and optimization of electrospray and heated nebulizer interfaces. J Chromatogr A 1996. [DOI: 10.1016/s0021-9673(96)00617-6] [Citation(s) in RCA: 69] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|
12
|
Careri M, Mangia A. Multidimensional detection methods for separations and their application in food analysis. Trends Analyt Chem 1996. [DOI: 10.1016/s0165-9936(96)00066-0] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
13
|
Affiliation(s)
- L. David Rothman
- Analytical Sciences Laboratory, The Dow Chemical Company, 1897B Building, Midland, Michigan 48667
| |
Collapse
|
14
|
Careri M, Mangia A, Musci M. Applications of liquid chromatography-mass spectrometry interfacing systems in food analysis: pesticide, drug and toxic substance residues. J Chromatogr A 1996; 727:153-84. [PMID: 8919666 DOI: 10.1016/0021-9673(95)01173-0] [Citation(s) in RCA: 65] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
This paper reviews applications of different LC-MS techniques for the determination of xenobiotic substances in foods. Specific examples of contaminants discussed are pesticides, herbicides, insecticides and drugs; concerning toxic substances, mycotoxins, phycotoxins, cyanobacterial toxins, mutagenic and heterocyclic amines and beta-carbolines, arsenic, tin and inorganic halogen compounds, packaging materials and various epoxy resins are considered. Advantages and limitations are outlined for the different LC-MS interfacing systems (particle beam, thermospray, atmospheric pressure ionization with electrospray, ionspray and heated pneumatic nebulizer). The impact of developments in instrumental analysis on methodology and the limitations of the various LC-MS methods are discussed. Further, the coupling of LC with element-selective detection systems such as inductively coupled plasma mass spectrometry is discussed, with emphasis on speciation of trace toxic elements in foods.
Collapse
Affiliation(s)
- M Careri
- Dipartimento di Chimica Generale ed Inorganica, Università degli Studi di Parma, Italy
| | | | | |
Collapse
|
15
|
Bonfanti L, Careri M, Mangia A, Manini P, Maspero M. Simultaneous identification of different classes of hydrocarbons and determination of nitro-polycyclic aromatic hydrocarbons by means of particle beam liquid chromatography-mass spectrometry. J Chromatogr A 1996. [DOI: 10.1016/0021-9673(95)01040-8] [Citation(s) in RCA: 33] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
16
|
Chapter 5. LC-MS: A New Window for Trace-Level Monitoring of Pesticides and their Transformation Products in Environmental Water Samples. ACTA ACUST UNITED AC 1996. [DOI: 10.1016/s0301-4770(08)60782-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/21/2023]
|
17
|
Pacifici R, Pichini S, Altieri I, Caronna A, Passa AR, Zuccaro P. High-performance liquid chromatographic-electrospray mass spectrometric determination of morphine and its 3- and 6-glucuronides: application to pharmacokinetic studies. JOURNAL OF CHROMATOGRAPHY. B, BIOMEDICAL APPLICATIONS 1995; 664:329-34. [PMID: 7780584 DOI: 10.1016/0378-4347(94)00496-r] [Citation(s) in RCA: 63] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Abstract
A rapid and selective assay of morphine and its 3- and 6-glucuronides in serum, based on high-performance liquid chromatography-electrospray mass spectrometry has been developed. The analytes and the internal standard, codeine or naltrexone, were subjected to solid-phase extraction, using ethyl solid-phase extraction columns, prior to chromatography. A reversed-phase column and a gradient mobile phase consisting of water and methanol were used. The mass spectrometer was operated in the selected-ion monitoring mode. The following ions were used: m/z 286 for morphine, m/z 300 for codeine, m/z 342 for naltrexone, and m/z 462 for morphine 3- and 6-glucuronides. The limit of quantitation observed with this method was 10 ng/ml morphine, 50 ng/ml morphine-6-glucuronide and 100 ng/ml morphine-3-glucuronide. The present method proved useful for the determination of serum levels of the parent drug and its metabolites in pain patients, heroin addicts and in morphine-treated mice.
Collapse
Affiliation(s)
- R Pacifici
- Clinical Biochemistry Department, Istituto Superiore di Sanità, Rome, Italy
| | | | | | | | | | | |
Collapse
|