1
|
Dovrou A, Nikiforaki K, Zaridis D, Manikis GC, Mylona E, Tachos N, Tsiknakis M, Fotiadis DI, Marias K. A segmentation-based method improving the performance of N4 bias field correction on T2weighted MR imaging data of the prostate. Magn Reson Imaging 2023; 101:1-12. [PMID: 37004467 DOI: 10.1016/j.mri.2023.03.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2022] [Revised: 03/15/2023] [Accepted: 03/21/2023] [Indexed: 04/03/2023]
Abstract
Magnetic Resonance (MR) images suffer from spatial inhomogeneity, known as bias field corruption. The N4ITK filter is a state-of-the-art method used for correcting the bias field to optimize MR-based quantification. In this study, a novel approach is presented to quantitatively evaluate the performance of N4 bias field correction for pelvic prostate imaging. An exploratory analysis, regarding the different values of convergence threshold, shrink factor, fitting level, number of iterations and use of mask, is performed to quantify the performance of N4 filter in pelvic MR images. The performance of a total of 240 different N4 configurations is examined using the Full Width at Half Maximum (FWHM) of the segmented periprostatic fat distribution as evaluation metric. Phantom T2weighted images were used to assess the performance of N4 for a uniform test tissue mimicking material, excluding factors such as patient related susceptibility and anatomy heterogeneity. Moreover, 89 and 204 T2weighted patient images from two public datasets acquired by scanners with a combined surface and endorectal coil at 1.5 T and a surface coil at 3 T, respectively, were utilized and corrected with a variable set of N4 parameters. Furthermore, two external public datasets were used to validate the performance of the N4 filter in T2weighted patient images acquired by various scanning conditions with different magnetic field strengths and coils. The results show that the set of N4 parameters, converging to optimal representations of fat in the image, were: convergence threshold 0.001, shrink factor 2, fitting level 6, number of iterations 100 and the use of default mask for prostate images acquired by a combined surface and endorectal coil at both 1.5 T and 3 T. The corresponding optimal N4 configuration for MR prostate images acquired by a surface coil at 1.5 T or 3 T was: convergence threshold 0.001, shrink factor 2, fitting level 5, number of iterations 25 and the use of default mask. Hence, periprostatic fat segmentation can be used to define the optimal settings for achieving T2weighted prostate images free from bias field corruption to provide robust input for further analysis.
Collapse
Affiliation(s)
- Aikaterini Dovrou
- Computational BioMedicine Laboratory (CBML), Institute of Computer Science, Foundation for Research and Technology - Hellas (FORTH), Heraklion, Greece.
| | - Katerina Nikiforaki
- Computational BioMedicine Laboratory (CBML), Institute of Computer Science, Foundation for Research and Technology - Hellas (FORTH), Heraklion, Greece
| | - Dimitris Zaridis
- Unit of Medical Technology and Intelligent Information Systems, Department of Materials Science and Engineering, University of Ioannina, Ioannina, Greece; Biomedical Research Institute, Foundation for Research and Technology - Hellas (FORTH), Ioannina, Greece; Biomedical Engineering Laboratory, School of Electrical and Computer Engineering, National Technical University of Athens, Athens, Greece
| | - Georgios C Manikis
- Computational BioMedicine Laboratory (CBML), Institute of Computer Science, Foundation for Research and Technology - Hellas (FORTH), Heraklion, Greece
| | - Eugenia Mylona
- Unit of Medical Technology and Intelligent Information Systems, Department of Materials Science and Engineering, University of Ioannina, Ioannina, Greece; Biomedical Research Institute, Foundation for Research and Technology - Hellas (FORTH), Ioannina, Greece
| | - Nikolaos Tachos
- Unit of Medical Technology and Intelligent Information Systems, Department of Materials Science and Engineering, University of Ioannina, Ioannina, Greece; Biomedical Research Institute, Foundation for Research and Technology - Hellas (FORTH), Ioannina, Greece
| | - Manolis Tsiknakis
- Computational BioMedicine Laboratory (CBML), Institute of Computer Science, Foundation for Research and Technology - Hellas (FORTH), Heraklion, Greece; Department of Electrical & Computer Engineering, Hellenic Mediterranean University, Heraklion, Greece
| | - Dimitrios I Fotiadis
- Unit of Medical Technology and Intelligent Information Systems, Department of Materials Science and Engineering, University of Ioannina, Ioannina, Greece; Biomedical Research Institute, Foundation for Research and Technology - Hellas (FORTH), Ioannina, Greece
| | - Kostas Marias
- Computational BioMedicine Laboratory (CBML), Institute of Computer Science, Foundation for Research and Technology - Hellas (FORTH), Heraklion, Greece; Department of Electrical & Computer Engineering, Hellenic Mediterranean University, Heraklion, Greece
| |
Collapse
|
2
|
Pham TX, Siarry P, Oulhadj H. Segmentation of MR Brain Images Through Hidden Markov Random Field and Hybrid Metaheuristic Algorithm. IEEE TRANSACTIONS ON IMAGE PROCESSING : A PUBLICATION OF THE IEEE SIGNAL PROCESSING SOCIETY 2020; 29:6507-6522. [PMID: 32365028 DOI: 10.1109/tip.2020.2990346] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Image segmentation is one of the most critical tasks in Magnetic Resonance (MR) images analysis. Since the performance of most current image segmentation methods is suffered by noise and intensity non-uniformity artifact (INU), a precise and artifact resistant method is desired. In this work, we propose a new segmentation method combining a new Hidden Markov Random Field (HMRF) model and a novel hybrid metaheuristic method based on Cuckoo search (CS) and Particle swarm optimization algorithms (PSO). The new model uses adaptive parameters to allow balancing between the segmented components of the model. In addition, to improve the quality of searching solutions in the Maximum a posteriori (MAP) estimation of the HMRF model, the hybrid metaheuristic algorithm is introduced. This algorithm takes into account both the advantages of CS and PSO algorithms in searching ability by cooperating them with the same population in a parallel way and with a solution selection mechanism. Since CS and PSO are performing exploration and exploitation in the search space, respectively, hybridizing them in an intelligent way can provide better solutions in terms of quality. Furthermore, initialization of the population is carefully taken into account to improve the performance of the proposed method. The whole algorithm is evaluated on benchmark images including both the simulated and real MR brain images. Experimental results show that the proposed method can achieve satisfactory performance for images with noise and intensity inhomogeneity, and provides better results than its considered competitors.
Collapse
|
3
|
Lang A, Carass A, Jedynak BM, Solomon SD, Calabresi PA, Prince JL. Intensity inhomogeneity correction of SD-OCT data using macular flatspace. Med Image Anal 2018; 43:85-97. [PMID: 29040910 PMCID: PMC6311386 DOI: 10.1016/j.media.2017.09.008] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2017] [Revised: 09/25/2017] [Accepted: 09/29/2017] [Indexed: 01/12/2023]
Abstract
Images of the retina acquired using optical coherence tomography (OCT) often suffer from intensity inhomogeneity problems that degrade both the quality of the images and the performance of automated algorithms utilized to measure structural changes. This intensity variation has many causes, including off-axis acquisition, signal attenuation, multi-frame averaging, and vignetting, making it difficult to correct the data in a fundamental way. This paper presents a method for inhomogeneity correction by acting to reduce the variability of intensities within each layer. In particular, the N3 algorithm, which is popular in neuroimage analysis, is adapted to work for OCT data. N3 works by sharpening the intensity histogram, which reduces the variation of intensities within different classes. To apply it here, the data are first converted to a standardized space called macular flat space (MFS). MFS allows the intensities within each layer to be more easily normalized by removing the natural curvature of the retina. N3 is then run on the MFS data using a modified smoothing model, which improves the efficiency of the original algorithm. We show that our method more accurately corrects gain fields on synthetic OCT data when compared to running N3 on non-flattened data. It also reduces the overall variability of the intensities within each layer, without sacrificing contrast between layers, and improves the performance of registration between OCT images.
Collapse
Affiliation(s)
- Andrew Lang
- Department of Electrical and Computer Engineering, The Johns Hopkins University, Baltimore, MD 21218, USA.
| | - Aaron Carass
- Department of Electrical and Computer Engineering, The Johns Hopkins University, Baltimore, MD 21218, USA; Department of Computer Science, The Johns Hopkins University, Baltimore, MD 21218, USA.
| | - Bruno M Jedynak
- Department of Mathematics and Statistics, Portland State University, Portland, OR 97201, USA.
| | - Sharon D Solomon
- Department of Ophthalmology, The Johns Hopkins School of Medicine, Baltimore, MD 21287, USA.
| | - Peter A Calabresi
- Department of Neurology, The Johns Hopkins School of Medicine, Baltimore, MD 21287, USA.
| | - Jerry L Prince
- Department of Electrical and Computer Engineering, The Johns Hopkins University, Baltimore, MD 21218, USA.
| |
Collapse
|
4
|
Liu L, Kan A, Leckie C, Hodgkin PD. Comparative evaluation of performance measures for shading correction in time-lapse fluorescence microscopy. J Microsc 2016; 266:15-27. [PMID: 28000921 DOI: 10.1111/jmi.12512] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2016] [Accepted: 11/10/2016] [Indexed: 01/10/2023]
Abstract
Time-lapse fluorescence microscopy is a valuable technology in cell biology, but it suffers from the inherent problem of intensity inhomogeneity due to uneven illumination or camera nonlinearity, known as shading artefacts. This will lead to inaccurate estimates of single-cell features such as average and total intensity. Numerous shading correction methods have been proposed to remove this effect. In order to compare the performance of different methods, many quantitative performance measures have been developed. However, there is little discussion about which performance measure should be generally applied for evaluation on real data, where the ground truth is absent. In this paper, the state-of-the-art shading correction methods and performance evaluation methods are reviewed. We implement 10 popular shading correction methods on two artificial datasets and four real ones. In order to make an objective comparison between those methods, we employ a number of quantitative performance measures. Extensive validation demonstrates that the coefficient of joint variation (CJV) is the most applicable measure in time-lapse fluorescence images. Based on this measure, we have proposed a novel shading correction method that performs better compared to well-established methods for a range of real data tested.
Collapse
Affiliation(s)
- L Liu
- Department of Computing and Information Systems, The University of Melbourne, Parkville, Australia
| | - A Kan
- Division of Immunology, Walter and Eliza Hall Institute of Medical Research, Parkville, Australia
| | - C Leckie
- Department of Computing and Information Systems, The University of Melbourne, Parkville, Australia
| | - P D Hodgkin
- Division of Immunology, Walter and Eliza Hall Institute of Medical Research, Parkville, Australia
| |
Collapse
|
5
|
Ganzetti M, Wenderoth N, Mantini D. Quantitative Evaluation of Intensity Inhomogeneity Correction Methods for Structural MR Brain Images. Neuroinformatics 2016; 14:5-21. [PMID: 26306865 PMCID: PMC4706843 DOI: 10.1007/s12021-015-9277-2] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
Abstract
The correction of intensity non-uniformity (INU) in magnetic resonance (MR) images is extremely important to ensure both within-subject and across-subject reliability. Here we tackled the problem of objectively comparing INU correction techniques for T1-weighted images, which are the most commonly used in structural brain imaging. We focused our investigations on the methods integrated in widely used software packages for MR data analysis: FreeSurfer, BrainVoyager, SPM and FSL. We used simulated data to assess the INU fields reconstructed by those methods for controlled inhomogeneity magnitudes and noise levels. For each method, we evaluated a wide range of input parameters and defined an enhanced configuration associated with best reconstruction performance. By comparing enhanced and default configurations, we found that the former often provide much more accurate results. Accordingly, we used enhanced configurations for a more objective comparison between methods. For different levels of INU magnitude and noise, SPM and FSL, which integrate INU correction with brain segmentation, generally outperformed FreeSurfer and BrainVoyager, whose methods are exclusively dedicated to INU correction. Nonetheless, accurate INU field reconstructions can be obtained with FreeSurfer on images with low noise and with BrainVoyager for slow and smooth inhomogeneity profiles. Our study may prove helpful for an accurate selection of the INU correction method to be used based on the characteristics of actual MR data.
Collapse
Affiliation(s)
- Marco Ganzetti
- Neural Control of Movement Laboratory, ETH Zurich, 8057, Zurich, Switzerland.,Department of Experimental Psychology, University of Oxford, Oxford, OX1 3UD, UK
| | - Nicole Wenderoth
- Neural Control of Movement Laboratory, ETH Zurich, 8057, Zurich, Switzerland.,Laboratory of Movement Control and Neuroplasticity, KU Leuven, 3001, Leuven, Belgium
| | - Dante Mantini
- Neural Control of Movement Laboratory, ETH Zurich, 8057, Zurich, Switzerland. .,Department of Experimental Psychology, University of Oxford, Oxford, OX1 3UD, UK.
| |
Collapse
|
6
|
Ganzetti M, Wenderoth N, Mantini D. Intensity Inhomogeneity Correction of Structural MR Images: A Data-Driven Approach to Define Input Algorithm Parameters. Front Neuroinform 2016; 10:10. [PMID: 27014050 PMCID: PMC4791378 DOI: 10.3389/fninf.2016.00010] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2015] [Accepted: 02/26/2016] [Indexed: 12/03/2022] Open
Abstract
Intensity non-uniformity (INU) in magnetic resonance (MR) imaging is a major issue when conducting analyses of brain structural properties. An inaccurate INU correction may result in qualitative and quantitative misinterpretations. Several INU correction methods exist, whose performance largely depend on the specific parameter settings that need to be chosen by the user. Here we addressed the question of how to select the best input parameters for a specific INU correction algorithm. Our investigation was based on the INU correction algorithm implemented in SPM, but this can be in principle extended to any other algorithm requiring the selection of input parameters. We conducted a comprehensive comparison of indirect metrics for the assessment of INU correction performance, namely the coefficient of variation of white matter (CVWM), the coefficient of variation of gray matter (CVGM), and the coefficient of joint variation between white matter and gray matter (CJV). Using simulated MR data, we observed the CJV to be more accurate than CVWM and CVGM, provided that the noise level in the INU-corrected image was controlled by means of spatial smoothing. Based on the CJV, we developed a data-driven approach for selecting INU correction parameters, which could effectively work on actual MR images. To this end, we implemented an enhanced procedure for the definition of white and gray matter masks, based on which the CJV was calculated. Our approach was validated using actual T1-weighted images collected with 1.5 T, 3 T, and 7 T MR scanners. We found that our procedure can reliably assist the selection of valid INU correction algorithm parameters, thereby contributing to an enhanced inhomogeneity correction in MR images.
Collapse
Affiliation(s)
- Marco Ganzetti
- Neural Control of Movement Laboratory, ETH ZurichZurich, Switzerland
- Department of Experimental Psychology, University of OxfordOxford, UK
| | - Nicole Wenderoth
- Neural Control of Movement Laboratory, ETH ZurichZurich, Switzerland
| | - Dante Mantini
- Neural Control of Movement Laboratory, ETH ZurichZurich, Switzerland
- Department of Experimental Psychology, University of OxfordOxford, UK
- Laboratory of Movement Control and Neuroplasticity, Katholieke Universiteit LeuvenLeuven, Belgium
| |
Collapse
|
7
|
Ivanovska T, Laqua R, Wang L, Schenk A, Yoon JH, Hegenscheid K, Völzke H, Liebscher V. An efficient level set method for simultaneous intensity inhomogeneity correction and segmentation of MR images. Comput Med Imaging Graph 2015; 48:9-20. [PMID: 26741125 DOI: 10.1016/j.compmedimag.2015.11.005] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2015] [Revised: 10/21/2015] [Accepted: 11/30/2015] [Indexed: 11/30/2022]
Abstract
Intensity inhomogeneity (bias field) is a common artefact in magnetic resonance (MR) images, which hinders successful automatic segmentation. In this work, a novel algorithm for simultaneous segmentation and bias field correction is presented. The proposed energy functional allows for explicit regularization of the bias field term, making the model more flexible, which is crucial in presence of strong inhomogeneities. An efficient minimization procedure, attempting to find the global minimum, is applied to the energy functional. The algorithm is evaluated qualitatively and quantitatively using a synthetic example and real MR images of different organs. Comparisons with several state-of-the-art methods demonstrate the superior performance of the proposed technique. Desirable results are obtained even for images with strong and complicated inhomogeneity fields and sparse tissue structures.
Collapse
Affiliation(s)
| | - René Laqua
- Ernst-Moritz-Arndt University, Greifswald, Germany
| | - Lei Wang
- Fraunhofer Institute for Medical Image Computing MEVIS, Bremen, Germany
| | - Andrea Schenk
- Fraunhofer Institute for Medical Image Computing MEVIS, Bremen, Germany
| | - Jeong Hee Yoon
- Department of Radiology, Seoul National University Hospital, Seoul, Republic of Korea
| | | | - Henry Völzke
- Ernst-Moritz-Arndt University, Greifswald, Germany
| | | |
Collapse
|
8
|
Zhang K, Liu Q, Song H, Li X. A Variational Approach to Simultaneous Image Segmentation and Bias Correction. IEEE TRANSACTIONS ON CYBERNETICS 2015; 45:1426-1437. [PMID: 25347891 DOI: 10.1109/tcyb.2014.2352343] [Citation(s) in RCA: 44] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
This paper presents a novel variational approach for simultaneous estimation of bias field and segmentation of images with intensity inhomogeneity. We model intensity of inhomogeneous objects to be Gaussian distributed with different means and variances, and then introduce a sliding window to map the original image intensity onto another domain, where the intensity distribution of each object is still Gaussian but can be better separated. The means of the Gaussian distributions in the transformed domain can be adaptively estimated by multiplying the bias field with a piecewise constant signal within the sliding window. A maximum likelihood energy functional is then defined on each local region, which combines the bias field, the membership function of the object region, and the constant approximating the true signal from its corresponding object. The energy functional is then extended to the whole image domain by the Bayesian learning approach. An efficient iterative algorithm is proposed for energy minimization, via which the image segmentation and bias field correction are simultaneously achieved. Furthermore, the smoothness of the obtained optimal bias field is ensured by the normalized convolutions without extra cost. Experiments on real images demonstrated the superiority of the proposed algorithm to other state-of-the-art representative methods.
Collapse
|