1
|
Chan BT, Yeoh HK, Liew YM, Aziz YFA, Sridhar GS, Hamilton-Craig C, Platts D, Lim E. Left ventricular flow propagation velocity measurement: Is it cast in stone? Med Biol Eng Comput 2017; 55:1883-1893. [PMID: 28321684 DOI: 10.1007/s11517-017-1639-5] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2016] [Accepted: 03/13/2017] [Indexed: 10/19/2022]
Abstract
This study aims to investigate the measurement of left ventricular flow propagation velocity, V p, using phase contrast magnetic resonance imaging and to assess the discrepancies resulting from inflow jet direction and individual left ventricular size. Three V p measuring techniques, namely non-adaptive (NA), adaptive positions (AP) and adaptive vectors (AV) method, were suggested and compared. We performed the comparison on nine healthy volunteers and nine post-infarct patients at four measurement positions, respectively, at one-third, one-half, two-thirds and the conventional 4 cm distances from the mitral valve leaflet into the left ventricle. We found that the V p measurement was affected by both the inflow jet direction and measurement positions. Both NA and AP methods overestimated V p, especially in dilated left ventricles, while the AV method showed the strongest correlation with the isovolumic relaxation myocardial strain rate (r = 0.53, p < 0.05). Using the AV method, notable difference in mean V p was also observed between healthy volunteers and post-infarct patients at positions of: one-half (81 ± 31 vs. 58 ± 25 cm/s), two-thirds (89 ± 32 vs. 45 ± 15 cm/s) and 4 cm (98 ± 23 vs. 47 ± 13 cm/s) distances. The use of AV method and measurement position at one-half distance was found to be the most suitable method for assessing diastolic dysfunction given varying left ventricular sizes and inflow jet directions.
Collapse
Affiliation(s)
- Bee Ting Chan
- Department of Biomedical Engineering, Faculty of Engineering, University of Malaya, 50603, Kuala Lumpur, Malaysia
| | - Hak Koon Yeoh
- Department of Chemical Engineering, Faculty of Engineering, University of Malaya, 50603, Kuala Lumpur, Malaysia.,Seri Kembangan Engineering Sdn. Bhd., 61-1, Jalan Anggerik Vanilla T, Kota Kemuning, 40460, Shah Alam, Malaysia
| | - Yih Miin Liew
- Department of Biomedical Engineering, Faculty of Engineering, University of Malaya, 50603, Kuala Lumpur, Malaysia
| | - Yang Faridah Abdul Aziz
- Department of Biomedical Imaging, University Malaya Research Imaging Centre, Faculty of Medicine, University of Malaya, 50603, Kuala Lumpur, Malaysia
| | | | - Christian Hamilton-Craig
- Heart and Lung Institute, The Prince Charles Hospital, Chermside, QLD, 4032, Australia.,School of Medicine, University of Queensland, Brisbane, QLD, 4006, Australia
| | - David Platts
- School of Medicine, University of Queensland, Brisbane, QLD, 4006, Australia.,Department of Echocardiography, The Prince Charles Hospital, Chermside, QLD, 4032, Australia
| | - Einly Lim
- Department of Biomedical Engineering, Faculty of Engineering, University of Malaya, 50603, Kuala Lumpur, Malaysia.
| |
Collapse
|
2
|
Elbaz MSM, van der Geest RJ, Calkoen EE, de Roos A, Lelieveldt BPF, Roest AAW, Westenberg JJM. Assessment of viscous energy loss and the association with three-dimensional vortex ring formation in left ventricular inflow: In vivo evaluation using four-dimensional flow MRI. Magn Reson Med 2016; 77:794-805. [PMID: 26924448 PMCID: PMC5297883 DOI: 10.1002/mrm.26129] [Citation(s) in RCA: 76] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2015] [Revised: 11/20/2015] [Accepted: 12/24/2015] [Indexed: 11/08/2022]
Abstract
PURPOSE To evaluate viscous energy loss and the association with three-dimensional (3D) vortex ring formation in left ventricular (LV) blood flow during diastolic filling. THEORY AND METHODS Thirty healthy volunteers were compared with 32 patients with corrected atrioventricular septal defect as unnatural mitral valve morphology and inflow are common in these patients. 4DFlow MRI was acquired from which 3D vortex ring formation was identified in LV blood flow at peak early (E)-filling and late (A)-filling and characterized by its presence/absence, orientation, and position from the lateral wall. Viscous energy loss was computed over E-filling, A-filling, and complete diastole using the Navier-Stokes energy equations. RESULTS Compared with healthy volunteers, viscous energy loss was significantly elevated in patients with disturbed vortex ring formation as characterized by a significantly inclined orientation and/or position closer to the lateral wall. Highest viscous energy loss was found in patients without a ring-shaped vortex during E-filling (on average more than double compared with patients with ring-shape vortex, P < 0.003). Altered A-filling vortex ring formation was associated with significant increase in total viscous energy loss over diastole even in the presence of normal E-filling vortex ring. CONCLUSION Altered vortex ring formation during LV filling is associated with increased viscous energy loss. Magn Reson Med 77:794-805, 2017. © 2016 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution-NonCommercial License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes.
Collapse
Affiliation(s)
| | | | - Emmeline E Calkoen
- Division of Paediatric Cardiology, Leiden University Medical Center, Leiden, The Netherlands; Department of Paediatrics, Leiden University Medical Center, Leiden, The Netherlands
| | - Albert de Roos
- Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands
| | - Boudewijn P F Lelieveldt
- Division of Image Processing, Department of Radiology.,Department of Intelligent Systems, Delft University of Technology, Delft, The Netherlands
| | - Arno A W Roest
- Division of Paediatric Cardiology, Leiden University Medical Center, Leiden, The Netherlands; Department of Paediatrics, Leiden University Medical Center, Leiden, The Netherlands
| | | |
Collapse
|