1
|
Reiss S, Wäscher K, Caglar Özen A, Lottner T, Timo Heidt, von Zur Mühlen C, Bock M. Quantifying myocardial perfusion during MR-guided interventions without exogenous contrast agents: intra-arterial spin labeling. Z Med Phys 2023:S0939-3889(23)00002-8. [PMID: 36717310 DOI: 10.1016/j.zemedi.2023.01.002] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2022] [Revised: 01/05/2023] [Accepted: 01/05/2023] [Indexed: 01/30/2023]
Abstract
PURPOSE To test intra-arterial spin labeling (iASL) using active guiding catheters for myocardial perfusion measurements during magnetic resonance (MR)-guided interventions in a pig study. METHODS In this work, a single-loop radiofrequency (RF) coil at the tip of a 6F active coronary catheter was used as a transmit coil for local spin labeling. The transmit magnetic RF field (B1) of the coil and the labeling efficiency were determined, and iASL was tested in two pigs after the catheter was engaged in the aortic root, the ostium of the left coronary artery (LCA) under MR-guidance. The iASL effect was assessed by the signal difference between spin-labeling On and control (spin-labeling OFF) images, and in a cross-correlation between ON/Off states of spin-labeling a binary labeling paradigm. In addition, quantitative myocardial perfusion was calculated from the iASL experiments. RESULTS The maximum B1 in the vicinity of the catheter coil was 2.1 µT. A strong local labeling effect with a labeling efficiency of 0.45 was achieved with iASL both in vitro and in vivo. In both pigs, the proximal myocardial segments supplied by the LCA showed significant labelling effect up to distances of 60 mm from the aortic root with a relative signal difference of (3.14 ± 2.89)% in the first and (3.50 ± 1.25)% in the second animal. The mean correlation coefficients were R = 0.63 ± 0.22 and 0.42 ± 0.16, respectively. The corresponding computed myocardial perfusion values in this region of the myocardium were similar to those obtained with contrast perfusion methods ((1.2 ± 1.1) mL/min/g and (0.8 ± 0.6) mL/min/g). CONCLUSION The proposed iASL method demonstrates the feasibility of selective myocardial perfusion measurements during MR-guided coronary interventions, which with further technical improvements may provide an alternative to exogenous contrast-based perfusion. Due to the invasive nature of the iASL method, it can potentially be used in concert with MRI-guided coronary angioplasty.
Collapse
Affiliation(s)
- Simon Reiss
- Department of Diagnostic and Interventional Radiology, Medical Physics, Medical Center University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany.
| | - Kevin Wäscher
- Department of Diagnostic and Interventional Radiology, Medical Physics, Medical Center University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Ali Caglar Özen
- Department of Diagnostic and Interventional Radiology, Medical Physics, Medical Center University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Thomas Lottner
- Department of Diagnostic and Interventional Radiology, Medical Physics, Medical Center University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Timo Heidt
- Department of Cardiology and Angiology I, University Heart Center Freiburg-Bad Krozingen, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Constantin von Zur Mühlen
- Department of Cardiology and Angiology I, University Heart Center Freiburg-Bad Krozingen, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Michael Bock
- Department of Diagnostic and Interventional Radiology, Medical Physics, Medical Center University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| |
Collapse
|
2
|
Fan L, Allen BD, Culver AE, Hsu LY, Hong K, Benefield BC, Carr JC, Lee DC, Kim D. A theoretical framework for retrospective T 2 ∗ correction to the arterial input function in quantitative myocardial perfusion MRI. Magn Reson Med 2021; 86:1137-1144. [PMID: 33759238 DOI: 10.1002/mrm.28760] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2020] [Revised: 02/10/2021] [Accepted: 02/12/2021] [Indexed: 12/22/2022]
Abstract
PURPOSE To develop and evaluate a flexible, Bloch-equation based framework for retrospective T 2 ∗ correction to the arterial input function (AIF) obtained with quantitative cardiac perfusion pulse sequences. METHODS Our framework initially calculates the gadolinium concentration [Gd] based on T1 measurements alone. Next, T 2 ∗ is estimated from this initial calculation of [Gd] while assuming fast water exchange and using the literature native T2 and static magnetic field variation (ΔB0 ) values. Finally, the [Gd] is recalculated after performing T 2 ∗ correction to the Bloch equation signal model. Using this approach, we performed T 2 ∗ correction to historical phantom and in vivo, dual-imaging perfusion data sets from 3 different patient groups obtained using different pulse sequences and imaging parameters. Images were processed to quantify both the AIF and resting myocardial blood flow (MBF). We also performed a sensitivity analysis of our T 2 ∗ correction to ±20% variations in native T2 and ΔB0 . RESULTS Compared with the ground truth [Gd] of phantom, the normalized root-means-square-error (NRMSE) in measured [Gd] was 5.1%, 1.3%, and 0.6% for uncorrected, our corrected, and Kellman's corrected, respectively. For in vivo data, both the peak AIF (7.0 ± 3.0 mM vs. 8.6 ± 7.1 mM, 7.2 ± 0.9 mM vs. 8.6 ± 1.7 mM, 7.7 ± 1.8 mM vs. 10.3 ± 5.1 mM, P < .001) and resting MBF (1.3 ± 0.1 mL/g/min vs. 1.1 ± 0.1 mL/g/min, 1.3 ± 0.1 mL/g/min vs. 1.1 ± 0.1 mL/g/min, 1.2 ± 0.1 mL/g/min vs. 0.9 ± 0.1 mL/g/min, P < .001) values were significantly different between uncorrected and corrected for all 3 patient groups. Both the peak AIF and resting MBF values varied by <5% over the said variations in native T2 and ΔB0 . CONCLUSION Our theoretical framework enables retrospective T 2 ∗ correction to the AIF obtained with dual-imaging, cardiac perfusion pulse sequences.
Collapse
Affiliation(s)
- Lexiaozi Fan
- Department of Radiology, Northwestern University Feinberg School of Medicine, Chicago, Illinois, USA.,Department of Biomedical Engineering, Northwestern University, Evanston, Illinois, USA
| | - Bradley D Allen
- Department of Radiology, Northwestern University Feinberg School of Medicine, Chicago, Illinois, USA
| | - Austin E Culver
- Division of Cardiology, Internal Medicine, Northwestern University Feinberg School of Medicine, Chicago, Illinois, USA
| | - Li-Yueh Hsu
- Department of Radiology and Imaging Sciences, National Institutes of Health, Bethesda, Maryland, USA
| | - Kyungpyo Hong
- Department of Radiology, Northwestern University Feinberg School of Medicine, Chicago, Illinois, USA
| | - Brandon C Benefield
- Division of Cardiology, Internal Medicine, Northwestern University Feinberg School of Medicine, Chicago, Illinois, USA
| | - James C Carr
- Department of Radiology, Northwestern University Feinberg School of Medicine, Chicago, Illinois, USA
| | - Daniel C Lee
- Division of Cardiology, Internal Medicine, Northwestern University Feinberg School of Medicine, Chicago, Illinois, USA
| | - Daniel Kim
- Department of Radiology, Northwestern University Feinberg School of Medicine, Chicago, Illinois, USA.,Department of Biomedical Engineering, Northwestern University, Evanston, Illinois, USA
| |
Collapse
|
3
|
Yadav NN, Yang X, Li Y, Li W, Liu G, van Zijl PCM. Detection of dynamic substrate binding using MRI. Sci Rep 2017; 7:10138. [PMID: 28860625 PMCID: PMC5579242 DOI: 10.1038/s41598-017-10545-1] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2017] [Accepted: 08/11/2017] [Indexed: 01/11/2023] Open
Abstract
Magnetic Resonance Imaging (MRI) is rarely used for molecular binding studies and never without synthetic metallic labels. We designed an MRI approach that can specifically detect the binding of natural substrates (i.e. no chemical labels). To accomplish such detection of substrate-target interaction only, we exploit (i) the narrow resonance of aliphatic protons in free substrate for selective radio-frequency (RF) labeling and, (ii) the process of immobilisation upon binding to a solid-like target for fast magnetic transfer of this label over protons in the target backbone. This cascade of events is ultimately detected with MRI using magnetic interaction between target and water protons. We prove this principle using caffeine as a substrate in vitro and then apply it in vivo in the mouse brain. The combined effects of continuous labeling (label pumping), dynamic reversible binding, and water detection was found to enhance the detection sensitivity by about two to three orders of magnitude.
Collapse
Affiliation(s)
- Nirbhay N Yadav
- Russell H. Morgan Department of Radiology and Radiological Science, The Johns Hopkins University School of Medicine, Baltimore, MD, USA.,F. M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
| | - Xing Yang
- Russell H. Morgan Department of Radiology and Radiological Science, The Johns Hopkins University School of Medicine, Baltimore, MD, USA.,Department of Nuclear Medicine, Peking University First Hospital, Beijing, P.R. China
| | - Yuguo Li
- Russell H. Morgan Department of Radiology and Radiological Science, The Johns Hopkins University School of Medicine, Baltimore, MD, USA.,F. M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
| | - Wenbo Li
- Russell H. Morgan Department of Radiology and Radiological Science, The Johns Hopkins University School of Medicine, Baltimore, MD, USA.,F. M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
| | - Guanshu Liu
- Russell H. Morgan Department of Radiology and Radiological Science, The Johns Hopkins University School of Medicine, Baltimore, MD, USA.,F. M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
| | - Peter C M van Zijl
- Russell H. Morgan Department of Radiology and Radiological Science, The Johns Hopkins University School of Medicine, Baltimore, MD, USA. .,F. M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA.
| |
Collapse
|