Stabinska J, Wittsack HJ, Lerman LO, Ljimani A, Sigmund EE. Probing Renal Microstructure and Function with Advanced Diffusion MRI: Concepts, Applications, Challenges, and Future Directions. J Magn Reson Imaging 2023:10.1002/jmri.29127. [PMID: 37991093 PMCID: PMC11117411 DOI: 10.1002/jmri.29127] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2023] [Revised: 10/26/2023] [Accepted: 10/27/2023] [Indexed: 11/23/2023] Open
Abstract
Diffusion measurements in the kidney are affected not only by renal microstructure but also by physiological processes (i.e., glomerular filtration, water reabsorption, and urine formation). Because of the superposition of passive tissue diffusion, blood perfusion, and tubular pre-urine flow, the limitations of the monoexponential apparent diffusion coefficient (ADC) model in assessing pathophysiological changes in renal tissue are becoming apparent and motivate the development of more advanced diffusion-weighted imaging (DWI) variants. These approaches take advantage of the fact that the length scale probed in DWI measurements can be adjusted by experimental parameters, including diffusion-weighting, diffusion gradient directions and diffusion time. This forms the basis by which advanced DWI models can be used to capture not only passive diffusion effects, but also microcirculation, compartmentalization, tissue anisotropy. In this review, we provide a comprehensive overview of the recent advancements in the field of renal DWI. Following a short introduction on renal structure and physiology, we present the key methodological approaches for the acquisition and analysis of renal DWI data, including intravoxel incoherent motion (IVIM), diffusion tensor imaging (DTI), non-Gaussian diffusion, and hybrid IVIM-DTI. We then briefly summarize the applications of these methods in chronic kidney disease and renal allograft dysfunction. Finally, we discuss the challenges and potential avenues for further development of renal DWI. LEVEL OF EVIDENCE: 5 TECHNICAL EFFICACY: Stage 2.
Collapse
Affiliation(s)
- Julia Stabinska
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, Maryland, USA
- Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
| | - Hans-Jörg Wittsack
- Department of Diagnostic and Interventional Radiology, Medical Faculty, Heinrich Heine University Düsseldorf, Dusseldorf, Germany
| | - Lilach O. Lerman
- Division of Nephrology and Hypertension and Department of Cardiovascular Medicine, Mayo Clinic, Rochester, MN, USA
| | - Alexandra Ljimani
- Department of Diagnostic and Interventional Radiology, Medical Faculty, Heinrich Heine University Düsseldorf, Dusseldorf, Germany
| | - Eric E. Sigmund
- Bernard and Irene Schwartz Center for Biomedical Imaging Center for Advanced Imaging Innovation and Research (CAI2R), New York University Langone Health, New York City, New York, USA
| |
Collapse
|
2
|
Gilani N, Mikheev A, Brinkmann IM, Basukala D, Benkert T, Kumbella M, Babb JS, Chandarana H, Sigmund EE. Characterization of motion dependent magnetic field inhomogeneity for DWI in the kidneys. Magn Reson Imaging 2023; 100:93-101. [PMID: 36924807 PMCID: PMC10108090 DOI: 10.1016/j.mri.2023.03.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2023] [Revised: 03/10/2023] [Accepted: 03/12/2023] [Indexed: 03/15/2023]
Abstract
PURPOSE Diffusion-weighted imaging (DWI) of the abdomen has increased dramatically for both research and clinical purposes. Motion and static field inhomogeneity related challenges limit image quality of abdominopelvic imaging with the most conventional echo-planar imaging (EPI) pulse sequence. While reversed phase encoded imaging is increasingly used to facilitate distortion correction, it typically assumes one motion independent magnetic field distribution. In this study, we describe a more generalized workflow for the case of kidney DWI in which the field inhomogeneity at multiple respiratory phases is mapped and used to correct all images in a multi-contrast DWI series. METHODS In this HIPAA-compliant and IRB-approved prospective study, 8 volunteers (6 M, ages 28-51) had abdominal imaging performed in a 3 T MRI system (MAGNETOM Prisma; Siemens Healthcare, Erlangen, Germany) with ECG gating. Coronal oblique T2-weighted HASTE images were collected for anatomical reference. Sagittal phase-contrast (PC) MRI images through the left renal artery were collected to determine systolic and diastolic phases. Cardiac triggered oblique coronal DWI were collected at 10 b-values between 0 and 800 s/mm2 and 12 directions. DWI series were distortion corrected using field maps generated by forward and reversed phase encoded b = 0 images collected over the full respiratory cycle and matched by respiratory phase. Morphologic accuracy, intraseries spatial variability, and diffusion tensor imaging (DTI) metrics mean diffusivity (MD) and fractional anisotropy (FA) were compared for results generated with no distortion correction, correction with only one respiratory bin, and correction with multiple respiratory bins across the breathing cycle. RESULTS Computed field maps showed significant variation in static field with kidney laterality, region, and respiratory phase. Distortion corrected images showed significantly better registration to morphologic images than uncorrected images; for the left kidney, the multiple bin correction outperformed one bin correction. Line profile analysis showed significantly reduced spatial variation with multiple bins than one bin correction. DTI metrics were mostly similar between correction methods, with some differences observed in MD between uncorrected and corrected datasets. CONCLUSIONS Our results indicate improved morphology of kidney DWI and derived parametric maps as well as reduced variability over the full image series using the motion-resolved distortion correction. This work highlights some morphologic and quantitative metric improvements can be obtained for kidney DWI when distortion correction is performed in a respiratory-resolved manner.
Collapse
Affiliation(s)
- Nima Gilani
- Center for Advanced Imaging and Innovation (CAI(2)R), Center for Biomedical Imaging, Department of Radiology, NYU Langone Health, New York, USA.
| | - Artem Mikheev
- Center for Advanced Imaging and Innovation (CAI(2)R), Center for Biomedical Imaging, Department of Radiology, NYU Langone Health, New York, USA
| | | | - Dibash Basukala
- Center for Advanced Imaging and Innovation (CAI(2)R), Center for Biomedical Imaging, Department of Radiology, NYU Langone Health, New York, USA
| | | | - Malika Kumbella
- Center for Advanced Imaging and Innovation (CAI(2)R), Center for Biomedical Imaging, Department of Radiology, NYU Langone Health, New York, USA
| | - James S Babb
- Center for Advanced Imaging and Innovation (CAI(2)R), Center for Biomedical Imaging, Department of Radiology, NYU Langone Health, New York, USA
| | - Hersh Chandarana
- Center for Advanced Imaging and Innovation (CAI(2)R), Center for Biomedical Imaging, Department of Radiology, NYU Langone Health, New York, USA
| | - Eric E Sigmund
- Center for Advanced Imaging and Innovation (CAI(2)R), Center for Biomedical Imaging, Department of Radiology, NYU Langone Health, New York, USA.
| |
Collapse
|
3
|
Sigmund EE, Mikheev A, Brinkmann IM, Gilani N, Babb JS, Basukala D, Benkert T, Veraart J, Chandarana H. Cardiac Phase and Flow Compensation Effects on REnal Flow and Microstructure AnisotroPy MRI in Healthy Human Kidney. J Magn Reson Imaging 2023; 58:210-220. [PMID: 36399101 PMCID: PMC10192459 DOI: 10.1002/jmri.28517] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2022] [Revised: 10/20/2022] [Accepted: 10/21/2022] [Indexed: 11/19/2022] Open
Abstract
BACKGROUND Renal diffusion-weighted imaging (DWI) involves microstructure and microcirculation, quantified with diffusion tensor imaging (DTI), intravoxel incoherent motion (IVIM), and hybrid models. A better understanding of their contrast may increase specificity. PURPOSE To measure modulation of DWI with cardiac phase and flow-compensated (FC) diffusion gradient waveforms. STUDY TYPE Prospective. POPULATION Six healthy volunteers (ages: 22-48 years, five females), water phantom. FIELD STRENGTH/SEQUENCE 3-T, prototype DWI sequence with 2D echo-planar imaging, and bipolar (BP) or FC gradients. 2D Half-Fourier Single-shot Turbo-spin-Echo (HASTE). Multiple-phase 2D spoiled gradient-echo phase contrast (PC) MRI. ASSESSMENT BP and FC water signal decays were qualitatively compared. Renal arteries and velocities were visualized on PC-MRI. Systolic (peak velocity), diastolic (end stable velocity), and pre-systolic (before peak velocity) phases were identified. Following mutual information-based retrospective self-registration of DWI within each kidney, and Marchenko-Pastur Principal Component Analysis (MPPCA) denoising, combined IVIM-DTI analysis estimated mean diffusivity (MD), fractional anisotropy (FA), and eigenvalues (λi) from tissue diffusivity (Dt ), perfusion fraction (fp ), and pseudodiffusivity (Dp , Dp,axial , Dp,radial ), for each tissue (cortex/medulla, segmented on b0/FA respectively), phase, and waveform (BP, FC). Monte Carlo water diffusion simulations aided data interpretation. STATISTICAL TESTS Mixed model regression probed differences between tissue types and pulse sequences. Univariate general linear model analysis probed variations among cardiac phases. Spearman correlations were measured between diffusion metrics and renal artery velocities. Statistical significance level was set at P < 0.05. RESULTS Water BP and FC signal decays showed no differences. Significant pulse sequence dependence occurred for λ1 , λ3 , FA, Dp , fp , Dp,axial , Dp,radial in cortex and medulla, and medullary λ2 . Significant cortex/medulla differences occurred with BP for all metrics except MD (systole [P = 0.224]; diastole [P = 0.556]). Significant phase dependence occurred for Dp , Dp,axial , Dp,radial for BP and medullary λ1 , λ2 , λ3 , MD for FC. FA correlated significantly with velocity. Monte Carlo simulations indicated medullary measurements were consistent with a 34 μm tubule diameter. DATA CONCLUSION Cardiac gating and flow compensation modulate of measurements of renal diffusion. EVIDENCE LEVEL 2 TECHNICAL EFFICACY STAGE: 2.
Collapse
Affiliation(s)
- Eric E Sigmund
- Center for Advanced Imaging and Innovation (CAI2R), Center for Biomedical Imaging, Department of Radiology, NYU Langone Health, New York, New York, USA
| | - Artem Mikheev
- Center for Advanced Imaging and Innovation (CAI2R), Center for Biomedical Imaging, Department of Radiology, NYU Langone Health, New York, New York, USA
| | | | - Nima Gilani
- Center for Advanced Imaging and Innovation (CAI2R), Center for Biomedical Imaging, Department of Radiology, NYU Langone Health, New York, New York, USA
| | - James S Babb
- Center for Advanced Imaging and Innovation (CAI2R), Center for Biomedical Imaging, Department of Radiology, NYU Langone Health, New York, New York, USA
| | - Dibash Basukala
- Center for Advanced Imaging and Innovation (CAI2R), Center for Biomedical Imaging, Department of Radiology, NYU Langone Health, New York, New York, USA
| | - Thomas Benkert
- Siemens Medical Solutions USA Inc., Malvern, Pennsylvania, USA
| | - Jelle Veraart
- Center for Advanced Imaging and Innovation (CAI2R), Center for Biomedical Imaging, Department of Radiology, NYU Langone Health, New York, New York, USA
| | - Hersh Chandarana
- Center for Advanced Imaging and Innovation (CAI2R), Center for Biomedical Imaging, Department of Radiology, NYU Langone Health, New York, New York, USA
| |
Collapse
|
4
|
Liu W, Liu H, Xie S, Masokano IB, Bai Y, Wang X, Zhong L, Wu Y, Nie J, Zhou G, Pei Y, Li W. Comparing the clinical utility of single-shot, readout-segmented and zoomit echo-planar imaging in diffusion-weighted imaging of the kidney at 3 T. Sci Rep 2022; 12:12389. [PMID: 35859112 PMCID: PMC9300617 DOI: 10.1038/s41598-022-16670-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2022] [Accepted: 07/13/2022] [Indexed: 12/04/2022] Open
Abstract
We compared the clinical utility of single-shot echo-planar imaging (SS-EPI) using different breathing schemes, readout-segmented EPI and zoomit EPI in the repeatability of apparent diffusion coefficient (ADC) measurements, cortico-medullary contrast to noise ratio (c-mCNR) and image quality. In this institutional review board-approved prospective study, some common clinically applicable diffusion-weighted imaging (b = 50, 400, 800 s/mm2) of kidney on 3.0 T MRI were performed on 22 volunteers using SS-EPI with breath-hold diffusion-weighted imaging (BH-DWI), free-breathing (FB-DWI), navigator-triggered (NT-DWI) and respiratory-triggered (RT-DWI), readout-segmented DWI (RS-DWI), and Zoomit DWI (Z-DWI). ADC and c-mCNR were measured in 12 anatomic locations (the upper, middle, and lower pole of the renal cortex and medulla), and image quality was assessed on these DWI sequences. A DWI with the optimal clinical utility was decided by systematically assessing the ADC repeatability, c-mCNR and image quality among the DWIs. For ADC measurements, Z-DWI had an excellent intra-observer agreement (intra-class correlation coefficients (ICCs): 0.876–0.944) and good inter-observer agreement (inter-class ICCs: 0.798–0.856) in six DWI sequences. Z-DWI had the highest ADC repeatability in most of the 12 anatomic locations of the kidneys (mean ADC absolute difference: 0.070–0.111 × 10−3 mm2/s, limit of agreement: 0.031–0.056 × 10−3 mm2/s). In all DWIs, Z-DWI yielded a slightly higher c-mCNR than other DWIs in most representative locations (P > 0.05), which was significantly higher than BH-DWI and FB-DWI in the middle pole of both kidneys and the upper pole of the left kidney (P < 0.05). In addition, Z-DWI yielded image quality that was similar to RT-DWI and NT-DWI (P > 0.05) and superior to BH-DWI, FB-DWI and RS-DWI (P < 0.05). Our results suggest that Z-DWI provides the highest ADC reproducibility, better c-mCNR and good image quality on 3.0 T MRI, making it the recommended sequence for clinical DWI of the kidney.
Collapse
Affiliation(s)
- Wenguang Liu
- Department of Radiology, Xiangya Hospital, Central South University, No. 87 Xiangya Rd., Kai Fu District, Changsha, 410008, Hunan, People's Republic of China.,National Clinical Research Center for Geriatric Disorders, Xiangya Hospital, Central South University, Changsha, 410008, Hunan, People's Republic of China
| | - Hui Liu
- Department of Radiology, Xiangya Hospital, Central South University, No. 87 Xiangya Rd., Kai Fu District, Changsha, 410008, Hunan, People's Republic of China
| | - Simin Xie
- Department of Radiology, Xiangya Hospital, Central South University, No. 87 Xiangya Rd., Kai Fu District, Changsha, 410008, Hunan, People's Republic of China
| | - Ismail Bilal Masokano
- Department of Radiology, The Third Xiangya Hospital, Central South University, Changsha, 410013, Hunan, People's Republic of China
| | - Yu Bai
- Department of Radiology, Xiangya Hospital, Central South University, No. 87 Xiangya Rd., Kai Fu District, Changsha, 410008, Hunan, People's Republic of China
| | - Xiao Wang
- Department of Radiology, Xiangya Hospital, Central South University, No. 87 Xiangya Rd., Kai Fu District, Changsha, 410008, Hunan, People's Republic of China
| | - Linhui Zhong
- Department of Radiology, Xiangya Hospital, Central South University, No. 87 Xiangya Rd., Kai Fu District, Changsha, 410008, Hunan, People's Republic of China
| | - Yi Wu
- Department of Radiology, Xiangya Hospital, Central South University, No. 87 Xiangya Rd., Kai Fu District, Changsha, 410008, Hunan, People's Republic of China
| | - Jilin Nie
- Department of Radiology, Xiangya Hospital, Central South University, No. 87 Xiangya Rd., Kai Fu District, Changsha, 410008, Hunan, People's Republic of China
| | - Gaofeng Zhou
- Department of Radiology, Xiangya Hospital, Central South University, No. 87 Xiangya Rd., Kai Fu District, Changsha, 410008, Hunan, People's Republic of China
| | - Yigang Pei
- Department of Radiology, Xiangya Hospital, Central South University, No. 87 Xiangya Rd., Kai Fu District, Changsha, 410008, Hunan, People's Republic of China. .,National Clinical Research Center for Geriatric Disorders, Xiangya Hospital, Central South University, Changsha, 410008, Hunan, People's Republic of China.
| | - Wenzheng Li
- Department of Radiology, Xiangya Hospital, Central South University, No. 87 Xiangya Rd., Kai Fu District, Changsha, 410008, Hunan, People's Republic of China. .,National Clinical Research Center for Geriatric Disorders, Xiangya Hospital, Central South University, Changsha, 410008, Hunan, People's Republic of China.
| |
Collapse
|