1
|
Grasselli G, Arigò A, Palma P, Famiglini G, Cappiello A. Latest Developments in Direct and Non-Direct LC-MS Methods Based on Liquid Electron Ionization (LEI). Crit Rev Anal Chem 2024:1-18. [PMID: 39046707 DOI: 10.1080/10408347.2024.2381543] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/25/2024]
Abstract
Mass spectrometry (MS) enables precise identification and quantification of molecules, particularly when combined with chromatography. The advent of atmospheric pressure ionization (API) techniques allowed the efficient coupling of liquid chromatography with MS (LC-MS), extending analyses to nonvolatile and thermolabile compounds. API techniques present limitations such as low informative capacity and reproducibility of mass spectra, increasing instrument complexity and costs. Other challenges include analyzing poorly polar molecules and matrix effects (ME), which negatively impact quantitative analyses, necessitating extensive sample purification or using expensive labeled standards. These limitations prompted the exploration of alternative solutions, leading to the development of the Liquid Electron Ionization (LEI) interface. The system has demonstrated excellent robustness and reproducibility. LEI has been employed to analyze various compounds, including pesticides, drugs of abuse, phenols, polycyclic aromatic hydrocarbons (PAHs), phthalates, and many others. Its versatility has been validated with single quadrupole, triple quadrupole, and QToF detectors, operating in electron ionization (EI) or chemical ionization (CI) modes and with both reverse phase liquid chromatography (RPLC) and normal phase liquid chromatography (NPLC). LEI has also been successfully integrated with the Microfluidic Open Interface (MOI), Membrane Introduction Mass Spectrometry (MIMS), and Microfluidic Water-Assisted Trap Focusing (M-WATF), broadening its application scope and consistently demonstrating promising results in terms of sensitivity and identification power. The most recent advancement is the development of Extractive-Liquid Sampling Electron Ionization-Mass Spectrometry (E-LEI-MS), a surface sampling and real-time analysis technique based on the LEI concept. This review article offers a comprehensive and up-to-date picture of the potential of LEI.
Collapse
Affiliation(s)
- Genny Grasselli
- Department of Pure and Applied Sciences, University of Urbino Carlo Bo, Urbino, Italy
| | - Adriana Arigò
- Department of Pure and Applied Sciences, University of Urbino Carlo Bo, Urbino, Italy
| | - Pierangela Palma
- Department of Pure and Applied Sciences, University of Urbino Carlo Bo, Urbino, Italy
| | - Giorgio Famiglini
- Department of Pure and Applied Sciences, University of Urbino Carlo Bo, Urbino, Italy
| | - Achille Cappiello
- Department of Pure and Applied Sciences, University of Urbino Carlo Bo, Urbino, Italy
| |
Collapse
|
2
|
Pereira Dos Santos NG, Maciel EVS, Vargas Medina DA, Lanças FM. NanoLC-EI-MS: Perspectives in Biochemical Analysis. Int J Mol Sci 2023; 24:11746. [PMID: 37511506 PMCID: PMC10380556 DOI: 10.3390/ijms241411746] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2023] [Revised: 07/14/2023] [Accepted: 07/18/2023] [Indexed: 07/30/2023] Open
Abstract
Although LC-MS with atmospheric pressure ionization (API) sources is the primary technique used in modern bioanalytical studies, electron ionization mass spectrometry (EI-MS) can provide some substantial advantages over it. EI-MS is a matrix effect-free technique that provides reproducible and comparable mass spectra, serving as a compound fingerprint for easy identification through automated comparison with spectral libraries. Leveraging EI-MS in biochemical studies can yield critical analytical benefits for targeted and untargeted analyses. However, to fully utilize EI-MS for heavy and non-volatile molecules, a new technology that enables the coupling of liquid chromatography with EI-MS is needed. Recent advancements in nanoLC have addressed the compatibility issues between LC and EI-MS, and innovative interfacing strategies such as Direct-EI, liquid electron ionization (LEI), and Cold-EI have extended the application of EI-MS beyond the determination of volatile organic molecules. This review provides an overview of the latest developments in nanoLC-EI-MS interfacing technologies, discussing their scope and limitations. Additionally, selected examples of nanoLC-EI-MS applications in the field of biochemical analysis are presented, highlighting the potential prospects and benefits that the establishment of this technique can bring to this field.
Collapse
Affiliation(s)
| | | | | | - Fernando Mauro Lanças
- Institute of Chemistry of São Carlos, University of São Paulo, São Carlos 13566-590, Brazil
| |
Collapse
|
3
|
Vargas Medina DA, Pereira dos Santos NG, Maciel EVS, Lanças FM. Current prospects on nano liquid chromatography coupled to electron ionization mass spectrometry (nanoLC-EI-MS). J LIQ CHROMATOGR R T 2022. [DOI: 10.1080/10826076.2022.2110114] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/15/2022]
|
4
|
Porous layer open tubular nano liquid chromatography directly coupled to electron ionization mass spectrometry. J Chromatogr A 2022; 1674:463143. [PMID: 35588591 DOI: 10.1016/j.chroma.2022.463143] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2022] [Revised: 04/29/2022] [Accepted: 05/11/2022] [Indexed: 11/20/2022]
Abstract
A 25 µm i.d x 1.2 m length PS-DVB porous layer open tubular column (PLOT) was prepared and assessed in the configuration of a nano liquid chromatography coupled to an electron ionization mass spectrometry system (OT-nanoLC-EI-Ms), via the direct insertion of the column outlet into the ionization source. The developed system's operational parameters were comprehensively studied, and the setup performance was investigated employing both unidimensional and column switching configurations. As a result, the OT-nanoLC-EI-MS system demonstrated competitive applicability in separating non-amenable ESI compounds, such as polyaromatic hydrocarbons (PAHs) and non-amenable GC compounds such as thermolabile pesticides. Furthermore, with excellent chromatographic performance, the PLOT columns can work under more compatible EI-detection conditions - such as the elution with 100% organic solvent. For example, PAHs retention factors ranged between 1.5 and 2.2 for 100% MeCN mobile phase, and more than 33,000 plates per meter for naphthalene at 50 nL/min flow rate. In analyzing thermolabile pesticides, the column switching PLOT-nanoLC-EI-MS system provided LODs of 25 µg/L, demonstrating suitable intra e interday reproducibility (% RSD < 13%, n = 3), and possibilities the direct injection of raw samples with suitable robustness.
Collapse
|
5
|
Famiglini G, Palma P, Termopoli V, Cappiello A. The history of electron ionization in LC-MS, from the early days to modern technologies: A review. Anal Chim Acta 2021; 1167:338350. [PMID: 34049632 DOI: 10.1016/j.aca.2021.338350] [Citation(s) in RCA: 22] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2020] [Revised: 02/18/2021] [Accepted: 02/20/2021] [Indexed: 02/06/2023]
Abstract
This review article traces the history of the use of liquid chromatography coupled with mass spectrometry (LC-MS) using electron ionization (EI) from the first attempts up to the present day. At the time of the first efforts to couple LC to MS, 70 eV EI was the most common ionization technique, typically used in gas chromatography-mass spectrometry (GC-MS) and providing highly reproducible mass spectra that could be collated in libraries. Therefore, it was obvious to transport this dominant approach to the early LC-MS coupling attempts. The use of LC coupled to EI-MS is challenging mainly due to restrictions related to high-vacuum and high-temperature conditions required for the operation of EI and the need to remove the eluent carrying the analyte before entering the ion source. The authors will take readers through a journey of about 50 years, showing how through the succession of different attempts it has been possible to successfully couple LC with EI-MS, which in principle appear to be incompatible.
Collapse
Affiliation(s)
- Giorgio Famiglini
- LC-MS Laboratory, Department of Pure and Applied Sciences, University of Urbino, Urbino, Italy.
| | - Pierangela Palma
- LC-MS Laboratory, Department of Pure and Applied Sciences, University of Urbino, Urbino, Italy
| | - Veronica Termopoli
- LC-MS Laboratory, Department of Pure and Applied Sciences, University of Urbino, Urbino, Italy
| | - Achille Cappiello
- LC-MS Laboratory, Department of Pure and Applied Sciences, University of Urbino, Urbino, Italy.
| |
Collapse
|
6
|
Vargas Medina DA, Pereira Dos Santos NG, da Silva Burato JS, Borsatto JVB, Lanças FM. An overview of open tubular liquid chromatography with a focus on the coupling with mass spectrometry for the analysis of small molecules. J Chromatogr A 2021; 1641:461989. [PMID: 33611115 DOI: 10.1016/j.chroma.2021.461989] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2020] [Revised: 01/29/2021] [Accepted: 02/09/2021] [Indexed: 01/22/2023]
Abstract
Open tubular liquid chromatography (OT-LC) can provide superior chromatographic performance and more favorable mass spectrometry (MS) detection conditions. These features could provide enhanced sensitivity when coupled with electrospray ionization sources (ESI-) and lead to unprecedented detection capabilities if interfaced with a highly structural informative electron ionization (EI) source. In the past, the exploitation of OT columns in liquid chromatography evolved slowly. However, the recent instrumental developments in capillary/nanoLC-MS created new opportunities in developing and applying OT-LC-MS. Currently, the analytical advantages of OT-LC-MS are mainly exploited in the fields of proteomics and biosciences analysis. Nevertheless, under the right conditions, OT-LC-MS can also offer superior chromatographic performance and enhanced sensitivity in analyzing small molecules. This review will provide an overview of the latest developments in OT-LC-MS, focusing on the wide variety of employed separation mechanisms, innovative stationary phases, emerging column fabrication technologies, and new OT formats. In the same way, the OT-LC's opportunities and shortcomings coupled to both ESI and EI will be discussed, highlighting the complementary character of those two ionization modes to expand the LC's detection boundaries in the performance of targeted and untargeted studies.
Collapse
Affiliation(s)
| | | | | | | | - Fernando Mauro Lanças
- University of São Paulo, São Carlos, Institute of Chemistry of São Carlos, SP, Brazil.
| |
Collapse
|
7
|
Rigano F, Tranchida PQ, Dugo P, Mondello L. High-performance liquid chromatography combined with electron ionization mass spectrometry: A review. Trends Analyt Chem 2019. [DOI: 10.1016/j.trac.2019.05.032] [Citation(s) in RCA: 29] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
8
|
Evaluation of a liquid electron ionization liquid chromatography-mass spectrometry interface. J Chromatogr A 2019; 1591:120-130. [PMID: 30660440 DOI: 10.1016/j.chroma.2019.01.034] [Citation(s) in RCA: 30] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2018] [Revised: 12/20/2018] [Accepted: 01/11/2019] [Indexed: 11/27/2022]
Abstract
Liquid Electron Ionization (LEI), is an innovative liquid chromatography-mass spectrometry (LC-MS) interface that converts liquid HPLC eluent to the gas-phase in a mass spectrometer equipped with an electron ionization (EI) source. LEI extends the electronic spectra libraries access to liquid chromatography, providing a powerful tool in the untargeted approacssh. Negligible matrix effects allow accurate quantitative information. The purpose of this research was to evaluate the main aspects concerning the interfacing process. These fundamental studies were necessary to understand the mechanism of LEI in details, and improve the interfacing process, especially regarding robustness and sensitivity. Hardware components were installed to prevent analytes precipitation, reduce thermal decomposition of sensitive compounds, and to stabilize the nano-flow delivery with different mobile-phase compositions. Particular attention was devoted to insulating the heated vaporization area from the LC part of the system. Experiments were performed to optimize the interface inner capillary dimensions, and other operative parameters, including temperature, gas and liquid flow rates. Test compounds of environmental interest were selected based on molecular weight, thermal stability, volatility, and polarity. Robustness was evaluated with a set of replicated injections and calibration experiments using a soil matrix as a test sample. MRM detection limits in the low-picogram range were obtained for five pesticides belonging to different classes in a soil sample. High-quality electron ionization mass spectra of a mixture of pesticides were also obtained.
Collapse
|
9
|
Sol-gel coated ion sources for liquid chromatography-direct electron ionization mass spectrometry. Anal Chim Acta 2017; 978:35-41. [DOI: 10.1016/j.aca.2017.04.026] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2017] [Revised: 04/07/2017] [Accepted: 04/09/2017] [Indexed: 11/24/2022]
|
10
|
Kroslakova I, Pedrussio S, Wolfram E. Direct Coupling of HPTLC with MALDI-TOF MS for Qualitative Detection of Flavonoids on Phytochemical Fingerprints. PHYTOCHEMICAL ANALYSIS : PCA 2016; 27:222-228. [PMID: 27313160 DOI: 10.1002/pca.2621] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/01/2016] [Revised: 03/23/2016] [Accepted: 03/24/2016] [Indexed: 06/06/2023]
Abstract
INTRODUCTION Thin layer chromatographic fingerprints of plant raw materials and extracts for food and pharma applications often focus on phenol carbonic acids and flavonoids. The visual detection and comparison of Rf values of applied reference substances only renders limited phytochemical information. Recently, direct coupling of TLC with MALDI-TOF MS has been successfully applied for analysis of biologically relevant compounds such as lipids. The mass analysis of low molecular weight TLC or HPTLC fingerprints of flavonoids has, to our knowledge, not yet been investigated. OBJECTIVES In this study, the feasibility of direct coupling of HPTLC with UV-MALDI-TOF MS for determination of molecular mass of the ubiquitously present flavonol glycoside, rutin, and flavone glycoside, luteolin-7-O-glucoside, as well as their corresponding aglycones, quercetin and luteolin, is demonstrated. METHODOLOGY HPTLC plate suitable for combination with a MALDI MS adapter was used for chromatographic separation of compounds of interest. After separation, the plate was sprayed with 2,5 dihydroxybenzoic acid as a MALDI matrix using an automated spraying device. After drying, the developed chromatograms were scanned by UV-MALDI-TOF MS in positive mode with a spatial resolution of 0.2 mm. RESULTS All compounds studied were distinctly detected in MALDI-TOF mass spectra. This is particularly pertinent for the co-eluted aglycones luteolin and quercetin, which could not have been distinguished by the common visual HPTLC derivatisation and evaluation. CONCLUSION This study demonstrates the potential of MALDI-TOF MS for the analysis of low molecular weight fingerprints of flavonoids directly from their HPTLC chromatogram. Copyright © 2016 John Wiley & Sons, Ltd.
Collapse
Affiliation(s)
- Ivana Kroslakova
- Zurich University of Applied Sciences, Institute of Chemistry and Biotechnology, Einsiedlerstrasse 31, CH-8820, Wädenswil, Switzerland
| | - Simona Pedrussio
- Zurich University of Applied Sciences, Institute of Chemistry and Biotechnology, Einsiedlerstrasse 31, CH-8820, Wädenswil, Switzerland
| | - Evelyn Wolfram
- Zurich University of Applied Sciences, Institute of Chemistry and Biotechnology, Einsiedlerstrasse 31, CH-8820, Wädenswil, Switzerland
| |
Collapse
|
11
|
del Mar Contreras M, Borrás-Linares I, Herranz-López M, Micol V, Segura-Carretero A. Further exploring the absorption and enterocyte metabolism of quercetin forms in the Caco-2 model using nano-LC-TOF-MS. Electrophoresis 2015; 37:998-1006. [DOI: 10.1002/elps.201500375] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2015] [Revised: 10/14/2015] [Accepted: 10/28/2015] [Indexed: 11/10/2022]
Affiliation(s)
- María del Mar Contreras
- Department of Analytical Chemistry, Faculty of Sciences; University of Granada; Granada Spain
- Research and Development Functional Food Centre (CIDAF), Bioregión Building; Health Science Technological Park; Granada Spain
| | - Isabel Borrás-Linares
- Research and Development Functional Food Centre (CIDAF), Bioregión Building; Health Science Technological Park; Granada Spain
| | - María Herranz-López
- Instituto de Biología Molecular y Celular (IBMC); Miguel Hernández University; Elche Alicante Spain
| | - Vicente Micol
- Instituto de Biología Molecular y Celular (IBMC); Miguel Hernández University; Elche Alicante Spain
| | - Antonio Segura-Carretero
- Department of Analytical Chemistry, Faculty of Sciences; University of Granada; Granada Spain
- Research and Development Functional Food Centre (CIDAF), Bioregión Building; Health Science Technological Park; Granada Spain
| |
Collapse
|