1
|
Krumplewski W, Rykowska I. New Materials for Thin-Film Solid-Phase Microextraction (TF-SPME) and Their Use for Isolation and Preconcentration of Selected Compounds from Aqueous, Biological and Food Matrices. Molecules 2024; 29:5025. [PMID: 39519666 PMCID: PMC11547565 DOI: 10.3390/molecules29215025] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2024] [Revised: 09/26/2024] [Accepted: 10/10/2024] [Indexed: 11/16/2024] Open
Abstract
Determination of a broad spectrum of analytes, carried out with analytical instruments in samples with complex matrices, including environmental, biological, and food samples, involves the development of new and selective sorption phases used in microextraction techniques that allow their isolation from the matrix. SPME solid-phase microextraction is compatible with green analytical chemistry among the sample preparation techniques, as it reduces the use of toxic organic solvents to the minimum necessary. Over the past two decades, it has undergone impressive progress, resulting in the development of the thin-film solid-phase microextraction technique, TF-SPME (the thin-film solid-phase microextraction), which is characterized by a much larger surface area of the sorption phase compared to that of the SPME fiber. TF-SPME devices, in the form of a mostly rectangular metal or polymer substrate onto which a thin film of sorption phase is applied, are characterized, among others, by a higher sorption capacity. In comparison with microextraction carried out on SPME fiber, they enable faster microextraction of analytes. The active phase on which analyte sorption occurs can be applied to the substrate through techniques such as dip coating, spin coating, electrospinning, rod coating, and spray coating. The dynamic development of materials chemistry makes it possible to use increasingly advanced materials as selective sorption phases in the TF-SPME technique: polymers, conducting polymers, molecularly imprinted polymers, organometallic frameworks, carbon nanomaterials, aptamers, polymeric ionic liquids, and deep eutectic solvents. Therefore, TF-SPME has been successfully used to prepare analytical samples to determine a broad spectrum of analytes in sample matrices: environmental, biological, and food. The work will be a review of the above-mentioned issues.
Collapse
Affiliation(s)
| | - Iwona Rykowska
- Department of Chemistry, Adam Mickiewicz University, Ul. Uniwersytetu Poznańskiego 8, 61-614 Poznań, Poland;
| |
Collapse
|
2
|
Belhameid A, Casado-Carmona FA, Megriche A, López-Lorente ÁI, Lucena R, Cárdenas S. On-site extraction of benzophenones from swimming pool water using hybrid tapes based on the integration of hydrophilic-lipophilic balance microparticles and an outer magnetic nanometric domain. Mikrochim Acta 2024; 191:513. [PMID: 39105990 PMCID: PMC11303577 DOI: 10.1007/s00604-024-06586-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2024] [Accepted: 07/22/2024] [Indexed: 08/07/2024]
Abstract
An on-site extraction device is presented consisting of scotch tape modified with concentric domains of micrometric hydrophilic-lipophilic balance (HLB) particles surrounded by a ring of nanometric magnetic ones. On the one hand, HLB microparticles are readily available at the surface of the tape, exposed to interact with the target analytes, being responsible for the extraction capacity of the sorptive phase. On the other hand, the presence of magnetic nanoparticles enables the attachment of the modified tape onto a metallic screw via a magnet, which is then coupled to a wireless drill, enabling the stirring of the microextraction device. Both are simply fixed to the cost-effective, flexible, and versatile support, i.e., scotch tape, owing to their adhesive properties. The microextraction device has been applied to the determination of six benzophenones in swimming pool water samples. The variables that may affect the extraction process have been evaluated. Under the optimum conditions and using liquid chromatography-tandem mass spectrometry as the instrumental technique, the method provided a limit of detection of 0.03 µg L-1. The intra-day precision, evaluated at three different concentration levels and expressed as relative standard deviation, was lower than 10%, which also comprises the variability within single-use sorptive tapes. The accuracy, calculated with spiked samples and expressed as relative recovery, ranged from 71 to 138%. The method was applied to the analysis of swimming pool water, revealing the presence of such compounds.
Collapse
Affiliation(s)
- Ahmed Belhameid
- Affordable and Sustainable Sample Preparation (AS2P) Research Group, Departamento de Química Analítica, Instituto Químico para la Energía y el Medioambiente IQUEMA, Universidad de Córdoba, Campus de Rabanales, Edificio Marie Curie, E-14071, Córdoba, Spain
- Laboratory of Applied Mineral Chemistry, Faculty of Sciences of Tunis, University of Tunis El Manar, University, Campus El Manar 1, 2092, Tunis, Tunisia
| | - Francisco Antonio Casado-Carmona
- Affordable and Sustainable Sample Preparation (AS2P) Research Group, Departamento de Química Analítica, Instituto Químico para la Energía y el Medioambiente IQUEMA, Universidad de Córdoba, Campus de Rabanales, Edificio Marie Curie, E-14071, Córdoba, Spain
- FI-TRACE Group, Department of Chemistry, Faculty of Science, University of the Balearic Islands, Illes Balears, Carretera de Valldemossa Km 7.5, E-07122, Palma de Mallorca, Spain
| | - Adel Megriche
- Laboratory of Applied Mineral Chemistry, Faculty of Sciences of Tunis, University of Tunis El Manar, University, Campus El Manar 1, 2092, Tunis, Tunisia
| | - Ángela Inmaculada López-Lorente
- Affordable and Sustainable Sample Preparation (AS2P) Research Group, Departamento de Química Analítica, Instituto Químico para la Energía y el Medioambiente IQUEMA, Universidad de Córdoba, Campus de Rabanales, Edificio Marie Curie, E-14071, Córdoba, Spain.
| | - Rafael Lucena
- Affordable and Sustainable Sample Preparation (AS2P) Research Group, Departamento de Química Analítica, Instituto Químico para la Energía y el Medioambiente IQUEMA, Universidad de Córdoba, Campus de Rabanales, Edificio Marie Curie, E-14071, Córdoba, Spain.
| | - Soledad Cárdenas
- Affordable and Sustainable Sample Preparation (AS2P) Research Group, Departamento de Química Analítica, Instituto Químico para la Energía y el Medioambiente IQUEMA, Universidad de Córdoba, Campus de Rabanales, Edificio Marie Curie, E-14071, Córdoba, Spain
| |
Collapse
|
3
|
Benedetti B, Ceccardi E, MacKeown H, Di Carro M, Magi E. Exploring the potentialities of a biodegradable polymeric film in sample preparation: An optimized "white" protocol to extract and quantify emerging contaminants in water. Anal Chim Acta 2024; 1311:342725. [PMID: 38816162 DOI: 10.1016/j.aca.2024.342725] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2024] [Revised: 04/29/2024] [Accepted: 05/15/2024] [Indexed: 06/01/2024]
Abstract
BACKGROUND The introduction of white analytical chemistry encourages the development of methods characterized by a balance among greenness, productivity/feasibility and analytical performances. In the environmental analysis of emerging contaminants (ECs), for which high sensitivity and specificity are mandatory, the use of green and sustainable sample preparation needs to be coupled to a reliable analytical determination. Herein, an extraction method based on the use of a biodegradable polymeric film (Mater-Bi) and coupled to LC-MS/MS analysis was developed for the sensitive determination of ECs in wastewater. RESULTS The interaction among a range of ECs and the Mater-Bi film (a commercially available patented blend of polybutylene-terephthalate, starch and fatty acids) was investigated by two sequential experimental designs, to simultaneously study several factors and optimize extraction efficiency. The final method, resembling a fabric phase sorptive extraction, involved pH and ionic strength modification of the sample, 1h extraction and desorption in ethanol. Satisfactory recoveries from real wastewater were obtained for sixteen analytes (56-116 %), as well as excellent precision (inter-day relative standard deviations below 10 % for most compounds). Matrix effect was in the range 88-116 % at the lower pre-concentration factor, but also acceptable in most cases at the higher pre-concentration factor. LODs in matrix, from 0.004 to 0.159 μg L-1, were lower than or comparable to those from recent studies employing green extraction procedures. The method demonstrated its applicability to samples from wastewater treatment plants, allowing quantification of pharmaceuticals and UV filters at the μg L-1 and ng L-1 levels, respectively. SIGNIFICANCE For the first time, the synthetic biopolymer Mater-Bi, so far unexplored for the use in analytical chemistry, was exploited for a green, simple and extremely cheap extraction protocol. The optimized method is suitable for several ECs, guaranteeing very good accuracy, precision and specificity, also thanks to the LC-MS/MS analysis. The evaluation by green and white analytical chemistry metrics highlighted its superiority to conventional extraction methods.
Collapse
Affiliation(s)
- Barbara Benedetti
- Department of Chemistry and Industrial Chemistry, University of Genoa, Via Dodecaneso 31, 16146, Genova, Italy.
| | - Erica Ceccardi
- Department of Chemistry and Industrial Chemistry, University of Genoa, Via Dodecaneso 31, 16146, Genova, Italy
| | - Henry MacKeown
- Department of Chemistry and Industrial Chemistry, University of Genoa, Via Dodecaneso 31, 16146, Genova, Italy
| | - Marina Di Carro
- Department of Chemistry and Industrial Chemistry, University of Genoa, Via Dodecaneso 31, 16146, Genova, Italy
| | - Emanuele Magi
- Department of Chemistry and Industrial Chemistry, University of Genoa, Via Dodecaneso 31, 16146, Genova, Italy
| |
Collapse
|
4
|
Benedetti B, Baglietto M, MacKeown H, Scapuzzi C, Di Carro M, Magi E. An optimized processing method for polar organic chemical integrative samplers deployed in seawater: Toward a maximization of the analysis accuracy for trace emerging contaminants. J Chromatogr A 2022; 1677:463309. [PMID: 35853423 DOI: 10.1016/j.chroma.2022.463309] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2022] [Revised: 07/04/2022] [Accepted: 07/05/2022] [Indexed: 10/17/2022]
Abstract
Passive sampling of emerging contaminants (ECs) in seawater represents a challenge in environmental monitoring. A specific protocol for Polar Organic Chemical Integrative Sampler (POCIS) processing may be necessary when dealing with marine applications, due to the peculiarity of the considered matrix. Herein, both the instrumental LC-MS/MS analysis and the sampler processing for the determination of 22 ECs in seawater were carefully optimized. The study entailed a test simulating POCIS sorbent exposure to seawater as well as the processing of replicated field POCIS with different elution solvents. The final method involved washing the sorbent with water, to eliminate most salts, and a two-step elution, by using methanol and a small volume of a dichloromethane-isopropanol mixture. With this protocol, recoveries between 58 and 137% (average 106%) were obtained for most analytes, including non-steroidal anti-inflammatory drugs, UV-filters, perfluorinated substances and caffeine. Still, the protocol was not suitable for very hydrophilic compounds (recovery under 20% for artificial sweeteners and the pharmaceutical salbutamol), which also showed remarkable ion suppression (matrix effects in the range 4-46%). For all other chemicals, the matrix effects were in the range 67-103% (average 86%), indicating satisfactory accuracy. Also, the overall method showed high sensitivity (detection limits in the range 0.04-9 ng g-1 of POCIS sorbent) and excellent specificity, thanks to the monitoring of two "precursor ion-product ion" MS transitions for identity confirmation. The method was applied to samplers deployed in the Ligurian coast (Italy), detecting caffeine, bisphenol A, ketoprofen and two UV-filters as the most concentrated in the POCIS sorbent.
Collapse
Affiliation(s)
- Barbara Benedetti
- Department of Chemistry and Industrial Chemistry, University of Genoa, via Dodecaneso 31, Genoa 16146, Italy
| | - Matteo Baglietto
- Department of Chemistry and Industrial Chemistry, University of Genoa, via Dodecaneso 31, Genoa 16146, Italy
| | - Henry MacKeown
- Department of Chemistry and Industrial Chemistry, University of Genoa, via Dodecaneso 31, Genoa 16146, Italy
| | - Chiara Scapuzzi
- Department of Chemistry and Industrial Chemistry, University of Genoa, via Dodecaneso 31, Genoa 16146, Italy
| | - Marina Di Carro
- Department of Chemistry and Industrial Chemistry, University of Genoa, via Dodecaneso 31, Genoa 16146, Italy.
| | - Emanuele Magi
- Department of Chemistry and Industrial Chemistry, University of Genoa, via Dodecaneso 31, Genoa 16146, Italy
| |
Collapse
|
5
|
Passive Sampling of Organic Contaminants as a Novel Approach to Monitor Seawater Quality in Aquarium Ocean Tanks. APPLIED SCIENCES-BASEL 2022. [DOI: 10.3390/app12062951] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
The determination of trace pollutants in seawater is challenging, and sampling is a crucial step in the entire analytical process. Passive samplers combine in situ sampling and preconcentration, thus limiting the tedious treatment steps of the conventional sampling methods. Their use to monitor water quality in confined marine environment could bring several advantages. In this work, the presence of organic contaminants at trace and ultra-trace levels was assessed in the Genoa Aquarium supply-and-treated water using Polar Organic Integrative Samplers (POCIS). Both untargeted gas chromatography-mass spectrometry and targeted liquid chromatography-tandem mass spectrometry were employed. The untargeted approach showed the presence of hydrocarbons, diphenyl sulfone and 2,4-di-tert-butyl-phenol. Only hydrocarbons were detected in all the samples. Nineteen emerging contaminants, belonging to different classes (pharmaceuticals, UV-filters, hormones and perfluorinated compounds), were selected for the target analysis. Thirteen analytes were detected, mainly in supply water, even though the majority of them were below the quantitation limit. It is worthy to note that two of the detected UV-filters had never been reported in seawater using the POCIS samplers. The comparison of the analytes detected in supply and treated water indicated a good performance of the Aquarium water treatment system in the abatement of seawater contaminants.
Collapse
|
6
|
Benefits of Innovative and Fully Water-Compatible Stationary Phases of Thin-Film Microextraction (TFME) Blades. Molecules 2021; 26:molecules26154413. [PMID: 34361565 PMCID: PMC8347298 DOI: 10.3390/molecules26154413] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2021] [Revised: 07/19/2021] [Accepted: 07/19/2021] [Indexed: 11/25/2022] Open
Abstract
Octadecyl (C18) groups are arguably the most popular ligands used for preparation of solid phase microextraction (SPME) devices. However, conventional C18-bonded silica particles are not fully compatible with the nearly 100% aqueous composition of typical biological samples (e.g., plasma, saliva, or urine). This study presents the first evaluation of thin-film SPME devices coated with special water-compatible C18-bonded particles. Device performance was assessed by extracting a mixture of 30 model compounds that exhibited various chemical structures and properties, such as hydrophobicity. Additionally, nine unique compositions of desorption solvents were tested. Thin-film SPME devices coated with C18-bonded silica particles with polar end-capping groups (10 µm) were compared with conventional trimethylsilane end-capped C18-bonded silica particles of various sizes (5, 10, and 45 µm) and characteristics. Polar end-capped particles provided the best extraction efficacy and were characterized by the strongest correlations between the efficacy of the extraction process and the hydrophobicity of the analytes. The results suggest that the original features of octadecyl ligands are best preserved in aqueous conditions by polar end-capped particles, unlike with conventional trimethylsilane end-capped particles that are currently used to prepare SPME devices. The benefits associated with this improved type of coating encourage further implementation of microextractraction as greener alternative to the traditional sample preparation methods.
Collapse
|
7
|
Magnetic paper-based sorptive phase for enhanced mass transference in stir membrane environmental samplers. Talanta 2021; 228:122217. [DOI: 10.1016/j.talanta.2021.122217] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2020] [Revised: 01/27/2021] [Accepted: 02/09/2021] [Indexed: 02/06/2023]
|