1
|
Modi RM, Cruz Marquez ML, Yang S, D’Angelo RN, Maher TR, Kreidieh B, Palmeri NO, Stabenau HF, Goldense D, Wacks E, Tung P, d’Avila A, Waks J, Zimetbaum P, Locke AH. Utility of an Externalized Temporary Transvenous Implantable Cardioverter-defibrillator System in the Setting of Ventricular Tachycardia Storm and Concurrent Device Infection Requiring Extraction. J Innov Card Rhythm Manag 2024; 15:5930-5934. [PMID: 39011464 PMCID: PMC11238887 DOI: 10.19102/icrm.2024.15071] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2024] [Accepted: 02/28/2024] [Indexed: 07/17/2024] Open
Abstract
With the expanding use of cardiac implantable electronic device (CIED) therapy, intravascular device infections are becoming more common. In the case of transvenous implantable cardioverter-defibrillator (ICD) infections requiring extraction for bacterial clearance, there remains no standard method to deliver temporary ICD therapy following device removal. We present a case of persistent bacteremia complicated by monomorphic ventricular tachycardia (VT) electrical storm where biventricular ICD system extraction was performed and a temporary transvenous dual-coil lead with an externalized ICD generator was used to treat VT episodes prior to the re-implantation of a new permanent system. This case demonstrates the utility of a temporary externalized transvenous ICD system in the successful detection and pace-termination of VT, thereby reducing episodes of painful and potentially harmful external defibrillator shocks during the treatment of CIED infection.
Collapse
Affiliation(s)
- Ronuk M. Modi
- Division of Cardiology, Beth Israel Deaconess Medical Center, Boston, MA, USA
| | | | - Shu Yang
- Division of Cardiology, Beth Israel Deaconess Medical Center, Boston, MA, USA
| | - Robert N. D’Angelo
- Division of Cardiology, Beth Israel Deaconess Medical Center, Boston, MA, USA
| | - Timothy R. Maher
- Division of Cardiology, Beth Israel Deaconess Medical Center, Boston, MA, USA
| | - Bahij Kreidieh
- Division of Cardiology, Beth Israel Deaconess Medical Center, Boston, MA, USA
| | | | - Hans F. Stabenau
- Division of Cardiology, Beth Israel Deaconess Medical Center, Boston, MA, USA
| | - Dana Goldense
- Division of Cardiology, Beth Israel Deaconess Medical Center, Boston, MA, USA
| | - Emily Wacks
- Division of Cardiology, Beth Israel Deaconess Medical Center, Boston, MA, USA
| | - Patricia Tung
- Division of Cardiology, Beth Israel Deaconess Medical Center, Boston, MA, USA
| | - Andre d’Avila
- Division of Cardiology, Beth Israel Deaconess Medical Center, Boston, MA, USA
| | - Jonathan Waks
- Division of Cardiology, Beth Israel Deaconess Medical Center, Boston, MA, USA
| | - Peter Zimetbaum
- Division of Cardiology, Beth Israel Deaconess Medical Center, Boston, MA, USA
| | - Andrew H. Locke
- Division of Cardiology, Beth Israel Deaconess Medical Center, Boston, MA, USA
| |
Collapse
|
2
|
Raghuram K, Nair KKM, Namboodiri N, Abhilash SP, Valaparambil AK. Clinical profile and outcomes of semi-permanent pacing in a tertiary care institute in southern India. Indian Pacing Electrophysiol J 2022; 23:17-20. [PMID: 36372273 PMCID: PMC9880884 DOI: 10.1016/j.ipej.2022.11.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2022] [Revised: 10/08/2022] [Accepted: 11/04/2022] [Indexed: 11/13/2022] Open
Abstract
BACKGROUND Semi-permanent pacing (SPP) includes the placement of a permanent lead through the internal jugular vein and connection to a pulse generator on the skin outside the venous access site. AIM To evaluate the clinical profile and outcomes of semi-permanent pacing in a tertiary care institute in Southern India. METHODS This is a retrospective observational study. All patients admitted and requiring management with semi-permanent pacing from January 2017 to June 2020 were included. RESULTS From January 2017 to June 2020, 20 patients underwent semi-permanent pacing (SPP) with a median age of 54 (21-74) years. Males comprised a majority of the patients (55%). Hypertension was noted in 50% of patients and 30% were diabetic. The right internal jugular vein was the most common access in 95% of patients. The most common indication for semi-permanent pacing was pocket site infection in 30% of patients. There were no procedural complications. The median duration on SPP was 7 (5-14) days and the median duration of hospital stay was 13 (8-21) days. Permanent pacemaker implantation was done in 55% of patients. Mortality in our study group was 15% with 10% dying due to cardiogenic shock (post resuscitated cardiac arrest) and 5% dying due to non-cardiac cause (Epidural hematoma). CONCLUSION In our study, semi-permanent pacing was noted to be a safe procedure and was more commonly indicated in emergent conditions with complete heart block secondary to underlying reversible causes and in the management of pocket site infection.
Collapse
|
3
|
Phillips P, Krahn AD, Andrade JG, Chakrabarti S, Thompson CR, Harris DJ, Forman JM, Karim SS, Sterns LD, Fedoruk LM, Partlow E, Bashir J. Treatment and Prevention of Cardiovascular Implantable Electronic Device (CIED) Infections. CJC Open 2022; 4:946-958. [DOI: 10.1016/j.cjco.2022.07.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2022] [Accepted: 07/03/2022] [Indexed: 10/15/2022] Open
|
4
|
Falasconi G, D'Angelo G, Pannone L, Marzi A, Radinovic A, Mazzone P. Effective Antitachycardia Therapy by Temporary External Defibrillator Utilized as Bridge to Reimplantation. J Cardiovasc Imaging 2022; 30:149-150. [PMID: 35505508 PMCID: PMC9058634 DOI: 10.4250/jcvi.2021.0146] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2021] [Revised: 10/05/2021] [Accepted: 10/12/2021] [Indexed: 11/29/2022] Open
Affiliation(s)
- Giulio Falasconi
- Clinical Cardiology Unit, IRCCS San Raffaele University Hospital, Milan, Italy
| | - Giuseppe D'Angelo
- Department of Cardiac Electrophysiology and Arrhythmology, IRCCS San Raffaele Hospital and Vita-Salute University, Milan, Italy
| | - Luigi Pannone
- Clinical Cardiology Unit, IRCCS San Raffaele University Hospital, Milan, Italy
| | - Alessandra Marzi
- Department of Cardiac Electrophysiology and Arrhythmology, IRCCS San Raffaele Hospital and Vita-Salute University, Milan, Italy
| | - Andrea Radinovic
- Department of Cardiac Electrophysiology and Arrhythmology, IRCCS San Raffaele Hospital and Vita-Salute University, Milan, Italy
| | - Patrizio Mazzone
- Department of Cardiac Electrophysiology and Arrhythmology, IRCCS San Raffaele Hospital and Vita-Salute University, Milan, Italy
| |
Collapse
|
5
|
Ząbek A, Boczar K, Dębski M, Ulman M, Pfitzner R, Musiał R, Lelakowski J, Małecka B. Effectiveness and safety of transvenous extraction of single- versus dual-coil implantable cardioverter-defibrillator leads at single-center experience. Medicine (Baltimore) 2019; 98:e16548. [PMID: 31348275 PMCID: PMC6709158 DOI: 10.1097/md.0000000000016548] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
Abstract
The available literature lacks data concerning direct comparison of the effectiveness and safety of single- versus dual-coil implantable cardioverter-defibrillator (ICD) leads transvenous extraction. Certainly, additional shocking coil in superior vena cava adds to the amount of metal in the vascular system. Adhesions developing around the superior vena cava coil add to the difficulty of extraction of ICD lead if lead removal is required. The aim of the study was to assess the effectiveness and safety of single- and dual-coil ICD leads transvenous extraction using mechanical systems. We performed transvenous lead extraction (TLE) of 197 ICD leads in 196 patients. There were 46 (23.3%) dual-coil leads removed from 46 (23.5%) patients. Cardiovascular implantable electronic device-related infection was an indication for TLE in 25.0% of patients. The following extracting techniques were used: manual direct traction, mechanical telescopic sheaths, controlled-rotation mechanical sheaths, and femoral approach. Complete ICD lead removal and complete procedural success in both groups were similar (99.3% in single-coil vs 97.8% in dual-coil, P = .41 and 99.3% in single-coil vs 97.8% in dual-coil, P = 0.41, respectively). We did not find significant difference between major and minor complication rates in both groups (2.0% in single-coil vs 4.3% in dual-coil, and 0.7% in single-coil vs 0.0% in dual-coil, P = .58, respectively). There was 1 death associated with the TLE procedure of single-coil lead.This study shows that extraction of dual-coil leads seems to be comparably safe and effective to extraction of single-coil leads. On the other hand, it requires longer fluoroscopy time and frequent utilization of advanced tools.
Collapse
Affiliation(s)
| | | | | | | | - Roman Pfitzner
- Department of Cardiac and Vascular Surgery, The John Paul II Hospital
- Institute of Cardiology, Jagiellonian University Medical College
| | - Robert Musiał
- Department of Anesthesiology and Intensive Care, The John Paul II Hospital, Krakow, Poland
| | - Jacek Lelakowski
- Department of Electrocardiology
- Institute of Cardiology, Jagiellonian University Medical College
| | - Barbara Małecka
- Department of Electrocardiology
- Institute of Cardiology, Jagiellonian University Medical College
| |
Collapse
|