1
|
Okazaki N, Shino K, Yokoi H, Ohori T. Virtual triple-bundle ACL graft via femoral tunnels behind the resident's ridge on 3D CT demonstrates equivalent orientation to native ACL. J Exp Orthop 2025; 12:e70125. [PMID: 39759095 PMCID: PMC11696254 DOI: 10.1002/jeo2.70125] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/09/2024] [Revised: 10/24/2024] [Accepted: 11/01/2024] [Indexed: 01/07/2025] Open
Abstract
Purpose To clarify the femoral tunnel location for a virtual anterior cruciate ligament (ACL) graft to simulate the native ACL. Methods Three-dimensional (3D) computed tomography (CT) and magnetic resonance imaging (MRI) were obtained in 14 normal knees in full extension. Two types of virtual triple bundle ACL grafts (VACLG) were created. In one type, the femoral tunnels for anteromedial bundle (AM = AMM/anteromedial bundle medial part + AML/anteromedial bundle lateral part) and posterolateral bundle (PL) were positioned behind the resident's ridge (RR) based on the bone landmark strategy (BR-VACLG group). In the other type, the tunnels were placed on the RR (OR-VACLG group). VACLG was displayed as three straight lines by connecting the two centres of the femoral attachment areas of AM and PL to those of the three tibial footprints of AMM, AML and PL attachments on 3D CT, and then superimposed on MRI. The ACL/ACL graft-the tibial plateau (ACL-TP) angles were compared among normal ACL (N-ACL), BR-VACLG and OR-VACLG. Results The mean ACL-TP angles of N-ACL, BR-VACLG and OR-VACLG were 74.4 ± 3.4°, 75.2 ± 4.5° and 68.7 ± 5.0° for AMM, 81.9 ± 3.8°, 82.9 ± 5.1° and 76.3 ± 4.0° and for AML, 71.1 ± 6.4°, 70.0 ± 7.2° and 61.0 ± 4.7° for PL on the oblique-coronal slices; 55.3 ± 4.9° 53.9 ± 4.4° and 50.5 ± 4.3° for AMM; 54.9 ± 4.5°, 54.7 ± 2.6° and 50.7 ± 3.2° for AML; 51.4 ± 3.3°, 51.2 ± 2.4° and 48.1 ± 2.0° for PL on the oblique-sagittal slices. There was no significant difference in the angles between N-ACL and BR-VACLG, while those of AMM and PL in OR-VACLG were significantly lower compared to N-ACL. Conclusion The virtual triple bundle ACL graft via femoral tunnels behind the RR on 3D CT shows equivalent orientation to the native ACL on MRI in full extension. Level of Evidence Level III.
Collapse
Affiliation(s)
| | - Konsei Shino
- Sports Orthopaedic CenterYukioka HospitalOsakaJapan
| | | | - Tomoki Ohori
- Department of Orthopaedic SurgeryOsaka University Graduate School of MedicineSuitaJapan
| |
Collapse
|
2
|
Abdullah M, Hulleck AA, Katmah R, Khalaf K, El-Rich M. Multibody dynamics-based musculoskeletal modeling for gait analysis: a systematic review. J Neuroeng Rehabil 2024; 21:178. [PMID: 39369227 PMCID: PMC11452939 DOI: 10.1186/s12984-024-01458-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2024] [Accepted: 09/03/2024] [Indexed: 10/07/2024] Open
Abstract
Beyond qualitative assessment, gait analysis involves the quantitative evaluation of various parameters such as joint kinematics, spatiotemporal metrics, external forces, and muscle activation patterns and forces. Utilizing multibody dynamics-based musculoskeletal (MSK) modeling provides a time and cost-effective non-invasive tool for the prediction of internal joint and muscle forces. Recent advancements in the development of biofidelic MSK models have facilitated their integration into clinical decision-making processes, including quantitative diagnostics, functional assessment of prosthesis and implants, and devising data-driven gait rehabilitation protocols. Through an extensive search and meta-analysis of over 116 studies, this PRISMA-based systematic review provides a comprehensive overview of different existing multibody MSK modeling platforms, including generic templates, methods for personalization to individual subjects, and the solutions used to address statically indeterminate problems. Additionally, it summarizes post-processing techniques and the practical applications of MSK modeling tools. In the field of biomechanics, MSK modeling provides an indispensable tool for simulating and understanding human movement dynamics. However, limitations which remain elusive include the absence of MSK modeling templates based on female anatomy underscores the need for further advancements in this area.
Collapse
Affiliation(s)
- Muhammad Abdullah
- Department of Mechanical and Nuclear Engineering, Khalifa University, Abu Dhabi, UAE
| | - Abdul Aziz Hulleck
- Department of Mechanical and Nuclear Engineering, Khalifa University, Abu Dhabi, UAE
| | - Rateb Katmah
- Department of Biomedical and Biotechnology Engineering, Khalifa University, Abu Dhabi, UAE
| | - Kinda Khalaf
- Department of Biomedical and Biotechnology Engineering, Khalifa University, Abu Dhabi, UAE
| | - Marwan El-Rich
- Department of Mechanical and Nuclear Engineering, Khalifa University, Abu Dhabi, UAE.
| |
Collapse
|
3
|
Hamilton LD, Shelburne KB, Rullkoetter PJ, Barnes CL, Mannen EM. Kinematic Performance of Medial Pivot Total Knee Arthroplasty. J Arthroplasty 2024; 39:1595-1601.e7. [PMID: 38061399 PMCID: PMC11096005 DOI: 10.1016/j.arth.2023.11.038] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/07/2023] [Revised: 11/16/2023] [Accepted: 11/27/2023] [Indexed: 12/30/2023] Open
Abstract
BACKGROUND Total knee arthroplasty (TKA) implants have continued to evolve to accommodate new understandings of knee mechanics. The medial-pivot implant is a newer design, which is intended to limit anterior-posterior translation in the medial compartment while allowing lateral compartment translation. However, evidence for a generalized medial-pivot characteristic across all activities is limited. The purpose of the study was to quantify and compare in vivo knee joint kinematics using high-speed stereo radiography during activities of daily living in patients who have undergone a TKA with a cruciate sacrificing medial-pivot implant to age-matched and sex-matched native controls. METHODS Fifteen participants (7 patients, 4 women, mean age 70 years and 8 nonsymptomatic controls, 4 women, mean age 64 years) performed 6 functional tasks in high-speed stereo radiography: deep-knee lunge, chair rise, step down, gait, gait with 90° turn, and seated knee extension. Translational differences between groups (surgical versus control) were assessed for the medial and lateral condyle, while pivot location was normalized to subject-specific tibial plateau geometry. RESULTS The surgical cohort displayed a more constrained medial condyle that provided greater stability of the medial compartment and did not result in the paradoxical anterior translation at mid-flexion angles during weight-bearing activities, but was associated with less condylar translation than native knees. Additionally, the transverse tibial pivot location occurs most commonly in the middle third of the tibial plateau and secondarily on the medial third. CONCLUSIONS Some variability in pivot location occurs between activities and is more in nonsymptomatic, native knee controls.
Collapse
Affiliation(s)
- Landon D Hamilton
- Department of Mechanical and Materials Engineering, University of Denver, Denver, Colorado
| | - Kevin B Shelburne
- Department of Mechanical and Materials Engineering, University of Denver, Denver, Colorado
| | - Paul J Rullkoetter
- Department of Mechanical and Materials Engineering, University of Denver, Denver, Colorado
| | - C Lowry Barnes
- Department of Orthopaedic Surgery, University of Arkansas for Medical Sciences, Little Rock, Arkansas
| | - Erin M Mannen
- Department of Orthopaedic Surgery, University of Arkansas for Medical Sciences, Little Rock, Arkansas; Department of Mechanical and Biomedical Engineering, Boise State University, Boise, Idaho
| |
Collapse
|
4
|
Shiode R, Miyamura S, Kazui A, Yamamoto N, Miyake T, Iwahashi T, Tanaka H, Otake Y, Sato Y, Murase T, Abe S, Okada S, Oka K. Reproduction of forearm rotation dynamic using intensity-based biplane 2D-3D registration matching method. Sci Rep 2024; 14:5518. [PMID: 38448504 PMCID: PMC10918057 DOI: 10.1038/s41598-024-55956-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2023] [Accepted: 02/29/2024] [Indexed: 03/08/2024] Open
Abstract
This study aimed to reproduce and analyse the in vivo dynamic rotational motion of the forearm and to clarify forearm motion involvement and the anatomical function of the interosseous membrane (IOM). The dynamic forearm rotational motion of the radius and ulna was analysed in vivo using a novel image-matching method based on fluoroscopic and computed tomography images for intensity-based biplane two-dimensional-three-dimensional registration. Twenty upper limbs from 10 healthy volunteers were included in this study. The mean range of forearm rotation was 150 ± 26° for dominant hands and 151 ± 18° for non-dominant hands, with no significant difference observed between the two. The radius was most proximal to the maximum pronation relative to the ulna, moved distally toward 60% of the rotation range from maximum pronation, and again proximally toward supination. The mean axial translation of the radius relative to the ulna during forearm rotation was 1.8 ± 0.8 and 1.8 ± 0.9 mm for dominant and non-dominant hands, respectively. The lengths of the IOM components, excluding the central band (CB), changed rotation. The transverse CB length was maximal at approximately 50% of the rotation range from maximum pronation. Summarily, this study describes a detailed method for evaluating in vivo dynamic forearm motion and provides valuable insights into forearm kinematics and IOM function.
Collapse
Affiliation(s)
- Ryoya Shiode
- Department of Orthopaedic Surgery, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita, Osaka, 565-0871, Japan
| | - Satoshi Miyamura
- Department of Orthopaedic Surgery, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita, Osaka, 565-0871, Japan
| | - Arisa Kazui
- Department of Orthopaedic Surgery, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita, Osaka, 565-0871, Japan
| | - Natsuki Yamamoto
- Department of Orthopaedic Surgery, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita, Osaka, 565-0871, Japan
| | - Tasuku Miyake
- Department of Orthopaedic Surgery, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita, Osaka, 565-0871, Japan
| | - Toru Iwahashi
- Department of Orthopaedic Surgery, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita, Osaka, 565-0871, Japan
| | - Hiroyuki Tanaka
- Department of Orthopaedic Surgery, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita, Osaka, 565-0871, Japan
| | - Yoshito Otake
- Division of Information Science, Nara Institute of Science and Technology, 8916-5 Takayama, Ikoma, Nara, 630-0192, Japan
| | - Yoshinobu Sato
- Division of Information Science, Nara Institute of Science and Technology, 8916-5 Takayama, Ikoma, Nara, 630-0192, Japan
| | - Tsuyoshi Murase
- Department of Orthopaedic Surgery, Bell Land General Hospital, 500-3 Higashiyama, Naka-ku, Sakai, Osaka, 599-8247, Japan
| | - Shingo Abe
- Department of Orthopaedic Surgery, Toyonaka City Hospital, 4-14-1 Shibahara, Toyonaka, Osaka, 560-8565, Japan
| | - Seiji Okada
- Department of Orthopaedic Surgery, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita, Osaka, 565-0871, Japan
| | - Kunihiro Oka
- Department of Orthopaedic Surgery, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita, Osaka, 565-0871, Japan.
| |
Collapse
|
5
|
Gundapaneni D, Tsatalis JT, Laughlin RT, Goswami T. Anthropomorphic Characterization of Ankle Joint. Bioengineering (Basel) 2023; 10:1212. [PMID: 37892942 PMCID: PMC10604250 DOI: 10.3390/bioengineering10101212] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2023] [Revised: 10/07/2023] [Accepted: 10/12/2023] [Indexed: 10/29/2023] Open
Abstract
Even though total ankle replacement has emerged as an alternative treatment to arthrodesis, the long-term clinical results are unsatisfactory. Proper design of the ankle device is required to achieve successful arthroplasty results. Therefore, a quantitative knowledge of the ankle joint is necessary. In this pilot study, imaging data of 22 subjects (with both females and males and across three age groups) was used to measure the morphological parameters of the ankle joint. A total of 40 measurements were collected by creating sections in the sagittal and coronal planes for the tibia and talus. Statistical analyses were performed to compare genders, age groups, and image acquisition techniques used to generate 3D models. About 13 measurements derived for parameters (TiAL, SRTi, TaAL, SRTa, TiW, TaW, and TTL) that are very critical for the implant design showed significant differences (p-value < 0.05) between males and females. Young adults showed a significant difference (p-value < 0.05) compared to adults for 15 measurements related to critical tibial and talus parameters (TiAL, TiW, TML, TaAL, SRTa, TaW, and TTL), but no significant differences were observed between young adults and older adults, and between adults and older adults for most of the parameters. A positive correlation (r > 0.70) was observed between tibial and talar width values and between the sagittal radius values. When compared with morphological parameters obtained in this study, the sizes of current total ankle replacement devices can only fit a very limited group of people in this study. This pilot study contributes to the comprehensive understanding of the effects of gender and age group on ankle joint morphology and the relationship between tibial and talus parameters that can be used to plan and design ankle devices.
Collapse
Affiliation(s)
- Dinesh Gundapaneni
- Department of Biomedical, Industrial and Human Factors Engineering, Wright State University, Dayton, OH 45435, USA;
| | - James T. Tsatalis
- Department of Radiology, Miami Valley Hospital, Dayton, OH 45409, USA;
| | - Richard T. Laughlin
- Department of Orthopedic Surgery, Sports Medicine and Rehabilitation, Miami Valley Hospital, Dayton, OH 45409, USA;
| | - Tarun Goswami
- Department of Biomedical, Industrial and Human Factors Engineering, Wright State University, Dayton, OH 45435, USA;
- Department of Orthopedic Surgery, Sports Medicine and Rehabilitation, Miami Valley Hospital, Dayton, OH 45409, USA;
| |
Collapse
|
6
|
Kenmoku T, Matsuki K, Sonoda M, Ishida T, Sasaki S, Sasaki Y, Tazawa R, Banks SA, Takaso M. In Vivo Kinematic Analysis of the Axial Shoulder Rotation in the Standing and Supine Positions Using 3D/2D Registration and Electromyography. Cureus 2023; 15:e46154. [PMID: 37900413 PMCID: PMC10613113 DOI: 10.7759/cureus.46154] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/28/2023] [Indexed: 10/31/2023] Open
Abstract
Background There has been no report comparing shoulder kinematics and muscle activities during axial shoulder rotation in different positions. The purpose of this study was to investigate differences in shoulder kinematics and muscle activities during axial shoulder rotation in healthy subjects between standing and supine positions using three-dimensional/two-dimensional (3D/2D) registration techniques and electromyography (EMG). Methods Eleven healthy males agreed to participate in this study. We recorded the fluoroscopy time during active shoulder axial rotation with a 90° elbow flexion in both standing and supine positions, simultaneously recording surface EMG of the infraspinatus, anterior deltoid, posterior deltoid, and biceps brachii. Three-dimensional bone models were created from CT images, and shoulder kinematics were analyzed using 3D/2D registration techniques. Muscle activities were evaluated as a ratio of mean electromyographic values to 5-sec maximum voluntary isometric contractions. Results Scapular kinematics during axial shoulder rotation in the supine position showed similar patterns with those in the standing position. The scapula was more posteriorly tilted and more downwardly rotated in the supine posture than in standing (P < 0.001 for both). Acromiohumeral distance (AHD) in the supine posture was significantly larger than in standing. Muscle activities showed no significant differences between postures except for biceps (P < 0.001). Discussion Shoulder kinematics and muscle activities during axial rotation were similar in pattern between standing and supine postures, but there were shifts in scapular pose and AHD. The findings of this study suggest that posture may be an important consideration for the prescription of optimal shoulder therapy following surgery or for the treatment of shoulder disorders.
Collapse
Affiliation(s)
- Tomonori Kenmoku
- Department of Orthopaedic Surgery, Kitasato University Hospital, Sagamihara, JPN
| | - Keisuke Matsuki
- Sports Mecine & Joint Center, Funabashi Orthopaedic Hospital, Funabashi, JPN
| | - Masaru Sonoda
- Division of Radiology, Seirei Sakura Citizen Hospital, Sakura, JPN
| | - Takumi Ishida
- Division of Radiology, Seirei Sakura Citizen Hospital, Sakura, JPN
| | - Shuichi Sasaki
- Division of Rehabilitation, Kitasato University Hospital, Sagamihara, JPN
| | - Yu Sasaki
- Sports Medicine & Joint Center, Funabashi Orthopaedic Hospital, Funabashi, JPN
| | - Ryo Tazawa
- Department of Orthopaedic Surgery, Kitasato University School of Medicine, Sagamihara, JPN
| | - Scott A Banks
- Department of Mechanical & Aerospace Engineering, University of Florida, Gainesville, USA
| | - Masashi Takaso
- Department of Orthopaedic Surgery, Kitasato University School of Medicine, Sagamihara, JPN
| |
Collapse
|
7
|
Burton W, Crespo IR, Andreassen T, Pryhoda M, Jensen A, Myers C, Shelburne K, Banks S, Rullkoetter P. Fully automatic tracking of native glenohumeral kinematics from stereo-radiography. Comput Biol Med 2023; 163:107189. [PMID: 37393783 DOI: 10.1016/j.compbiomed.2023.107189] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2023] [Revised: 06/12/2023] [Accepted: 06/19/2023] [Indexed: 07/04/2023]
Abstract
The current work introduces a system for fully automatic tracking of native glenohumeral kinematics in stereo-radiography sequences. The proposed method first applies convolutional neural networks to obtain segmentation and semantic key point predictions in biplanar radiograph frames. Preliminary bone pose estimates are computed by solving a non-convex optimization problem with semidefinite relaxations to register digitized bone landmarks to semantic key points. Initial poses are then refined by registering computed tomography-based digitally reconstructed radiographs to captured scenes, which are masked by segmentation maps to isolate the shoulder joint. A particular neural net architecture which exploits subject-specific geometry is also introduced to improve segmentation predictions and increase robustness of subsequent pose estimates. The method is evaluated by comparing predicted glenohumeral kinematics to manually tracked values from 17 trials capturing 4 dynamic activities. Median orientation differences between predicted and ground truth poses were 1.7∘ and 8.6∘ for the scapula and humerus, respectively. Joint-level kinematics differences were less than 2∘ in 65%, 13%, and 63% of frames for XYZ orientation DoFs based on Euler angle decompositions. Automation of kinematic tracking can increase scalability of tracking workflows in research, clinical, or surgical applications.
Collapse
Affiliation(s)
- William Burton
- Center for Orthopaedic Biomechanics, University of Denver, 2155 E. Wesley Ave., Denver, CO, 80210, USA.
| | - Ignacio Rivero Crespo
- Center for Orthopaedic Biomechanics, University of Denver, 2155 E. Wesley Ave., Denver, CO, 80210, USA
| | - Thor Andreassen
- Center for Orthopaedic Biomechanics, University of Denver, 2155 E. Wesley Ave., Denver, CO, 80210, USA
| | - Moira Pryhoda
- Center for Orthopaedic Biomechanics, University of Denver, 2155 E. Wesley Ave., Denver, CO, 80210, USA
| | - Andrew Jensen
- Department of Mechanical and Aerospace Engineering, University of Florida, 939 Center Dr., Gainesville, FL, 32611, USA
| | - Casey Myers
- Center for Orthopaedic Biomechanics, University of Denver, 2155 E. Wesley Ave., Denver, CO, 80210, USA
| | - Kevin Shelburne
- Center for Orthopaedic Biomechanics, University of Denver, 2155 E. Wesley Ave., Denver, CO, 80210, USA
| | - Scott Banks
- Department of Mechanical and Aerospace Engineering, University of Florida, 939 Center Dr., Gainesville, FL, 32611, USA
| | - Paul Rullkoetter
- Center for Orthopaedic Biomechanics, University of Denver, 2155 E. Wesley Ave., Denver, CO, 80210, USA
| |
Collapse
|
8
|
Lu HY, Lin CC, Shih KS, Lu TW, Kuo MY, Li SY, Hsu HC. Integration of statistical shape modeling and alternating interpolation-based model tracking technique for measuring knee kinematics in vivo using clinical interleaved bi-plane fluoroscopy. PeerJ 2023; 11:e15371. [PMID: 37334125 PMCID: PMC10276557 DOI: 10.7717/peerj.15371] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2022] [Accepted: 04/18/2023] [Indexed: 06/20/2023] Open
Abstract
Background A 2D fluoroscopy/3D model-based registration with statistical shape modeling (SSM)-reconstructed subject-specific bone models will help reduce radiation exposure for 3D kinematic measurements of the knee using clinical alternating bi-plane fluoroscopy systems. The current study aimed to develop such an approach and evaluate in vivo its accuracy and identify the effects of the accuracy of SSM models on the kinematic measurements. Methods An alternating interpolation-based model tracking (AIMT) approach with SSM-reconstructed subject-specific bone models was used for measuring 3D knee kinematics from dynamic alternating bi-plane fluoroscopy images. A two-phase optimization scheme was used to reconstruct subject-specific knee models from a CT-based SSM database of 60 knees using one, two, or three pairs of fluoroscopy images. Using the CT-reconstructed model as a benchmark, the performance of the AIMT with SSM-reconstructed models in measuring bone and joint kinematics during dynamic activity was evaluated in terms of mean target registration errors (mmTRE) for registered bone poses and the mean absolute differences (MAD) for each motion component of the joint poses. Results The mmTRE of the femur and tibia for one image pair were significantly greater than those for two and three image pairs without significant differences between two and three image pairs. The MAD was 1.16 to 1.22° for rotations and 1.18 to 1.22 mm for translations using one image pair. The corresponding values for two and three image pairs were 0.75 to 0.89° and 0.75 to 0.79 mm; and 0.57 to 0.79° and 0.6 to 0.69 mm, respectively. The MAD values for one image pair were significantly greater than those for two and three image pairs without significant differences between two and three image pairs. Conclusions An AIMT approach with SSM-reconstructed models was developed, enabling the registration of interleaved fluoroscopy images and SSM-reconstructed models from more than one asynchronous fluoroscopy image pair. This new approach had sub-millimeter and sub-degree measurement accuracy when using more than one image pair, comparable to the accuracy of CT-based methods. This approach will be helpful for future kinematic measurements of the knee with reduced radiation exposure using 3D fluoroscopy with clinically alternating bi-plane fluoroscopy systems.
Collapse
Affiliation(s)
- Hsuan-Yu Lu
- Department of Biomedical Engineering, National Taiwan University, Taipei, Taiwan, R.O.C.
| | - Cheng-Chung Lin
- Department of Electrical Engineering, Fu-Jen Catholic University, New Taipei, Taiwan, R.O.C.
| | - Kao-Shang Shih
- Department of Orthopedics, Shin Kong Wu Ho-Su Memorial Hospital, Taipei, Taiwan, R.O.C.
| | - Tung-Wu Lu
- Department of Biomedical Engineering, National Taiwan University, Taipei, Taiwan, R.O.C.
- Department of Orthopaedic Surgery, School of Medicine, National Taiwan University, Taipei, Taiwan, R.O.C.
| | - Mei-Ying Kuo
- Department of Physical Therapy, China Medical University, Taichung, Taiwan, R.O.C.
| | - Song-Ying Li
- Department of Biomedical Engineering, National Taiwan University, Taipei, Taiwan, R.O.C.
| | - Horng-Chaung Hsu
- Department of Orthopaedic Surgery, China Medical University, Taichung, Taiwan, R.O.C.
| |
Collapse
|
9
|
Ikumi A, Yoshii Y, Iwahashi Y, Sashida S, Shrestha P, Xie C, Kitahara I, Ishii T. Comparison of 3D Bone Position Estimation Using QR Code and Metal Bead Markers. Diagnostics (Basel) 2023; 13:diagnostics13061141. [PMID: 36980448 PMCID: PMC10047530 DOI: 10.3390/diagnostics13061141] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2022] [Revised: 02/15/2023] [Accepted: 03/15/2023] [Indexed: 03/19/2023] Open
Abstract
To improve the accuracy of a 3D bone position estimation system that displays 3D images in response to changes in the position of fluoroscopic images, modified markers using quick response (QR) codes were developed. The aims of this study were to assess the accuracy of the estimated bone position on 3D images with reference to QR code markers on fluoroscopic images and to compare its accuracy with metal bead markers. Bone positions were estimated from reference points on a fluoroscopic image compared with those on a 3D image. The positional relationships of QR code and metal bead markers on the fluoroscopic image were compared with those on the 3D image in order to establish whether a 3D image may be drawn by tracking positional changes in radius models. Differences were investigated by comparing the distance between markers on the fluoroscopic image and that on the 3D image, which was projected on the monitor. The error ratio, which was defined as the difference in the measurement between the fluoroscopic and 3D images divided by the fluoroscopic measurement, was compared between QR code and metal bead markers. Error ratios for the QR code markers were 5.0 ± 2.0%, 6.4 ± 7.6%, and 1.0 ± 0.8% in the anterior–posterior view, ulnar side lateral view, and posterior–anterior view, respectively. Error ratios for the metal bead markers were 1.3 ± 1.7%, 13.8 ± 14.5%, and 4.7 ± 5.7% in the anterior–posterior view, ulnar side lateral view, and posterior–anterior view, respectively. The error ratio for the metal bead markers was smaller in the initial position (p < 0.01). However, the error ratios for the QR code markers were smaller in the lateral position and the posterior–anterior position (p < 0.05). In QR code marker tracking, tracking was successful even with discontinuous images. The accuracy of a 3D bone position estimation was increased by using the QR code marker system. QR code marker tracking facilitates real-time comparisons of dynamic changes in preoperative 3D and intraoperative fluoroscopic images.
Collapse
Affiliation(s)
- Akira Ikumi
- Department of Orthopaedic Surgery, Tsukuba University Hospital, Tsukuba 305-8576, Japan
| | - Yuichi Yoshii
- Department of Orthopaedic Surgery, Tokyo Medical University Ibaraki Medical Center, Ami 300-0395, Japan
- Correspondence: ; Tel.: +81-29-887-1161
| | | | | | - Pragyan Shrestha
- Center for Computational Sciences, Tsukuba University, Tsukuba 305-8577, Japan
| | - Chun Xie
- Center for Computational Sciences, Tsukuba University, Tsukuba 305-8577, Japan
| | - Itaru Kitahara
- Center for Computational Sciences, Tsukuba University, Tsukuba 305-8577, Japan
| | - Tomoo Ishii
- Department of Orthopaedic Surgery, Tokyo Medical University Ibaraki Medical Center, Ami 300-0395, Japan
| |
Collapse
|
10
|
Hamilton LD, Andreassen TE, Myers CA, Shelburne KB, Clary CW, Rullkoetter PJ. Knee pivot location in asymptomatic older adults. J Biomech 2023; 149:111487. [PMID: 36868041 PMCID: PMC10080542 DOI: 10.1016/j.jbiomech.2023.111487] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2022] [Revised: 01/28/2023] [Accepted: 02/06/2023] [Indexed: 02/11/2023]
Abstract
Representative data of asymptomatic, native-knee kinematics is important when studying changes in knee function across the lifespan. High-speed stereo radiography (HSSR) provides a reliable measure of knee kinematics to <1 mm of translation and 1° of rotation, but studies often have limited statistical power to make comparisons between groups or measure the contribution of individual variability. The purpose of this study is to examine in vivo condylar kinematics to quantify the transverse center-of-rotation, or pivot, location across the flexion range and challenge the medial-pivot paradigm in asymptomatic knee kinematics. We quantified the pivot location during supine leg press, knee extension, standing lunge, and gait for 53 middle-aged and older adults (27 men; 26 women: 50.8 ± 7.0 yrs, 1.75 ± 0.1 m, 79.1 ± 15.4 kg). A central- to medial-pivot location was identified for all activities with increased knee flexion associated with posterior translation of the center-of-rotation. The association between knee angle and anterior-posterior center-of-rotation location was not as strong as the relation between medial-lateral and anterior-posterior location, excluding gait. The Pearson's correlation for gait was stronger between knee angle and anterior-posterior center-of-rotation location (P < 0.001) than medial-lateral and anterior-posterior location (P = 0.0122). Individual variability accounted for a measurable proportion in variance explained of center-of-rotation location. Unique to gait, the lateral translation of center-of-rotation location resulted in the anterior translation of center-of-rotation at <10° knee flexion. Furthermore, no association between vertical ground-reaction force and center-of-rotation was identified.
Collapse
Affiliation(s)
| | | | - Casey A Myers
- University of Denver, Denver, CO, USA; Ortho Haus, LLC, CO, USA
| | | | - Chadd W Clary
- University of Denver, Denver, CO, USA; Ortho Haus, LLC, CO, USA
| | | |
Collapse
|
11
|
Oonk JGM, Dobbe JGG, Strackee SD, Strijkers GJ, Streekstra GJ. Quantification of the methodological error in kinematic evaluation of the DRUJ using dynamic CT. Sci Rep 2023; 13:3159. [PMID: 36823242 PMCID: PMC9950078 DOI: 10.1038/s41598-023-29726-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2022] [Accepted: 02/09/2023] [Indexed: 02/25/2023] Open
Abstract
Distal radio-ulnar joint (DRUJ) motion analysis using dynamic CT is gaining popularity. Following scanning and segmentation, 3D bone models are registered to (4D-)CT target frames. Imaging errors like low signal-to-noise ratio (SNR), limited Z-coverage and motion artefacts influence registration, causing misinterpretation of joint motion. This necessitates quantification of the methodological error. A cadaver arm and dynamic phantom were subjected to multiple 4D-CT scans, while varying tube charge-time product and phantom angular velocity, to evaluate the effects of SNR and motion artefacts on registration accuracy and precision. 4D-CT Z-coverage is limited by the scanner. To quantify the effects of different Z-coverages on registration accuracy and precision, 4D-CT was simulated by acquiring multiple spiral 3D-CT scans of the cadaver arm. Z-coverage was varied by clipping the 3D bone models prior to registration. The radius position relative to the ulna was obtained from the segmentation image. Apparent relative displacement seen in the target images is caused by registration errors. Worst-case translations were 0.45, 0.08 and 1.1 mm for SNR-, Z-coverage- and motion-related errors respectively. Worst-case rotations were 0.41, 0.13 and 6.0 degrees. This study showed that quantification of the methodological error enables composition of accurate and precise DRUJ motion scanning protocols.
Collapse
Affiliation(s)
- J. G. M. Oonk
- grid.509540.d0000 0004 6880 3010Department of Biomedical Engineering and Physics, Amsterdam UMC, Meibergdreef 9, 1105 AZ Amsterdam, The Netherlands ,Amsterdam Movement Sciences, Musculoskeletal Health, Restoration and Development, Amsterdam, The Netherlands
| | - J. G. G. Dobbe
- grid.509540.d0000 0004 6880 3010Department of Biomedical Engineering and Physics, Amsterdam UMC, Meibergdreef 9, 1105 AZ Amsterdam, The Netherlands ,Amsterdam Movement Sciences, Musculoskeletal Health, Restoration and Development, Amsterdam, The Netherlands
| | - S. D. Strackee
- grid.509540.d0000 0004 6880 3010Department of Plastic-, Reconstructive- and Handsurgery, Amsterdam UMC, Meibergdreef 9, 1105 AZ Amsterdam, The Netherlands
| | - G. J. Strijkers
- grid.509540.d0000 0004 6880 3010Department of Biomedical Engineering and Physics, Amsterdam UMC, Meibergdreef 9, 1105 AZ Amsterdam, The Netherlands
| | - G. J. Streekstra
- grid.509540.d0000 0004 6880 3010Department of Biomedical Engineering and Physics, Amsterdam UMC, Meibergdreef 9, 1105 AZ Amsterdam, The Netherlands
| |
Collapse
|
12
|
Petersen ET, Vind TD, Jürgens-Lahnstein JH, Christensen R, de Raedt S, Brüel A, Rytter S, Andersen MS, Stilling M. Evaluation of automated radiostereometric image registration in total knee arthroplasty utilizing a synthetic-based and a CT-based volumetric model. J Orthop Res 2023; 41:436-446. [PMID: 35532010 PMCID: PMC10084430 DOI: 10.1002/jor.25359] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/05/2022] [Revised: 03/28/2022] [Accepted: 05/05/2022] [Indexed: 02/04/2023]
Abstract
Radiostereometic analysis (RSA) is an accurate method for rigid body pose (position and orientation) in three-dimensional space. Traditionally, RSA is based on insertion of periprosthetic tantalum markers and manual implant contour selection which limit clinically application. We propose an automated image registration technique utilizing digitally reconstructed radiographs (DRR) of computed tomography (CT) volumetric bone models (autorsa-bone) as a substitute for tantalum markers. Furthermore, an automated synthetic volumetric representation of total knee arthroplasty implant models (autorsa-volume) to improve previous silhouette-projection methods (autorsa-surface). As reference, we investigated the accuracy of implanted tantalum markers (marker) or a conventional manually contour-based method (mbrsa) for the femur and tibia. The data are presented as mean (standard deviation). The autorsa-bone method displayed similar accuracy of -0.013 (0.075) mm compared to the gold standard method (marker) of -0.013 (0.085). The autorsa-volume with 0.034 (0.106) mm did not markedly improve the autorsa-surface with 0.002 (0.129) mm, and none of these reached the mbrsa method of -0.009 (0.094) mm. In conclusion, marker-free RSA is feasible with similar accuracy as gold standard utilizing DRR and CT obtained volumetric bone models. Furthermore, utilizing synthetic generated volumetric implant models could not improve the silhouette-based method. However, with a slight loss of accuracy the autorsa methods provide a feasible automated alternative to the semi-automated method.
Collapse
Affiliation(s)
- Emil Toft Petersen
- University Clinic for Hand, Hip and Knee Surgery, Holstebro Central Hospital, Holstebro, Denmark.,Department of Clinical Medicine, Aarhus University, Aarhus, Denmark.,AutoRSA Research Group, Orthopaedic Research Unit, Aarhus University Hospital, Aarhus, Denmark
| | - Tobias Dahl Vind
- Department of Clinical Medicine, Aarhus University, Aarhus, Denmark.,AutoRSA Research Group, Orthopaedic Research Unit, Aarhus University Hospital, Aarhus, Denmark
| | - Jonathan Hugo Jürgens-Lahnstein
- Department of Clinical Medicine, Aarhus University, Aarhus, Denmark.,AutoRSA Research Group, Orthopaedic Research Unit, Aarhus University Hospital, Aarhus, Denmark
| | - Rasmus Christensen
- Department of Clinical Medicine, Aarhus University, Aarhus, Denmark.,AutoRSA Research Group, Orthopaedic Research Unit, Aarhus University Hospital, Aarhus, Denmark
| | - Sepp de Raedt
- AutoRSA Research Group, Orthopaedic Research Unit, Aarhus University Hospital, Aarhus, Denmark
| | - Annemarie Brüel
- Department of Biomedicine, Aarhus University, Aarhus, Denmark
| | - Søren Rytter
- Department of Clinical Medicine, Aarhus University, Aarhus, Denmark.,AutoRSA Research Group, Orthopaedic Research Unit, Aarhus University Hospital, Aarhus, Denmark.,Department of Orthopaedic Surgery, Aarhus University Hospital, Aarhus, Denmark
| | | | - Maiken Stilling
- Department of Clinical Medicine, Aarhus University, Aarhus, Denmark.,AutoRSA Research Group, Orthopaedic Research Unit, Aarhus University Hospital, Aarhus, Denmark.,Department of Orthopaedic Surgery, Aarhus University Hospital, Aarhus, Denmark
| |
Collapse
|
13
|
Su P, Liu F, Zhang Y, Zhu JH, Zhang LC. Assessment of three-dimensional rotation of the shoulder complex and scapulohumeral rhythm during sagittal movement. J Back Musculoskelet Rehabil 2022; 36:503-515. [PMID: 36278340 DOI: 10.3233/bmr-220132] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
BACKGROUND Due to the influence of spinal and respiratory movements, it is difficult to accurately measure the range of motion of each joint. OBJECTIVE To conduct a three-dimensional (3D) measurement of each joint in the shoulder complex in different postures in the sagittal plane of the upper extremity. METHODS Thirteen healthy adults with no history of shoulder surgery for trauma or chronic pain were enrolled in the present study. The computed tomography (CT) imaging data of the shoulder complex were acquired in four postures via the reconstruction and alignment of 3D images. The angles of the postural changes were measured, and rotation vectors were used for descriptions and statistical analyses. RESULTS There was a statistical difference in the rotation angles between the dominant and non-dominant sides of the sternoclavicular joint when the posture changed from a resting position to a posterior inferior position. During the postural change from a resting position to a horizontal position, the regression coefficient (β) of the humerothoracic joint to the sternoclavicular joint was 0.191, and the β of the humerothoracic joint to the glenohumeral joint was 0.621. During the postural change from the horizontal position to the rear upper position, the β of the humerothoracic joint to the sternoclavicular joint was 0.316, and the β of the humerothoracic joint to the glenohumeral joint was 0.845. During the postural change from the resting position to the rear lower position, the β of the humerothoracic joint to the glenohumeral joint was 0.991. CONCLUSION The application of the image alignment technique enabled the direct and accurate measurement of the bony structures of the shoulder joint. The helical approach accurately described the scapulohumeral rhythm during 3D motion. There was a scapulohumeral rhythm of the shoulder complex during 3D composite sagittal movement, with different ratios for different joints and postures.
Collapse
|
14
|
Yoshii Y, Iwahashi Y, Sashida S, Shrestha P, Shishido H, Kitahara I, Ishii T. An Experimental Study of a 3D Bone Position Estimation System Based on Fluoroscopic Images. Diagnostics (Basel) 2022; 12:diagnostics12092237. [PMID: 36140638 PMCID: PMC9497817 DOI: 10.3390/diagnostics12092237] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2022] [Revised: 09/01/2022] [Accepted: 09/14/2022] [Indexed: 11/16/2022] Open
Abstract
To compare a 3D preoperative planning image and fluoroscopic image, a 3D bone position estimation system that displays 3D images in response to changes in the position of fluoroscopic images was developed. The objective of the present study was to evaluate the accuracy of the estimated position of 3D bone images with reference to fluoroscopic images. Bone positions were estimated from reference points on a fluoroscopic image compared with those on a 3D image. The four reference markers positional relationships on the fluoroscopic image were compared with those on the 3D image to evaluate whether a 3D image may be drawn by tracking positional changes in the radius model. Intra-class correlations coefficients for reference marker distances between the fluoroscopic image and 3D image were 0.98–0.99. Average differences between measured values on the fluoroscopic image and 3D bone image for each marker corresponding to the direction of the bone model were 1.1 ± 0.7 mm, 2.4 ± 1.8 mm, 1.4 ± 0.8 mm, and 2.0 ± 1.6 mm in the anterior-posterior view, ulnar side lateral view, posterior-anterior view, and radial side lateral view, respectively. Marker positions were more accurate in the anterior-posterior and posterior-anterior views than in the radial and ulnar side lateral views. This system helps in real-time comparison of dynamic changes in preoperative 3D and intraoperative fluoroscopy images.
Collapse
Affiliation(s)
- Yuichi Yoshii
- Department of Orthopedic Surgery, Tokyo Medical University Ibaraki Medical Center, Ami, Ibaraki 300-0398, Japan
- Correspondence: ; Tel.: +81-298871161
| | | | | | - Pragyan Shrestha
- Center for Computational Sciences, Tsukuba University, Tsukuba, Ibaraki 305-8577, Japan
| | - Hidehiko Shishido
- Center for Computational Sciences, Tsukuba University, Tsukuba, Ibaraki 305-8577, Japan
| | - Itaru Kitahara
- Center for Computational Sciences, Tsukuba University, Tsukuba, Ibaraki 305-8577, Japan
| | - Tomoo Ishii
- Department of Orthopedic Surgery, Tokyo Medical University Ibaraki Medical Center, Ami, Ibaraki 300-0398, Japan
| |
Collapse
|
15
|
Nakazoe Y, Yonekura A, Takita H, Miyaji T, Okazaki N, Chiba K, Kidera K, Miyamoto T, Tomita M, Gamada K, Osaki M. Differences in the flexion and extension phases during kneeling investigated by kinematic and contact point analyses: a cross-sectional study. J Orthop Surg Res 2022; 17:192. [PMID: 35346292 PMCID: PMC8961915 DOI: 10.1186/s13018-022-03080-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/10/2021] [Accepted: 03/16/2022] [Indexed: 11/10/2022] Open
Abstract
Background Kneeling is necessary for certain religious and ceremonial occasions, crouching work, and gardening, which many people take part in worldwide. However, there have been few reports about kneeling activities. The purpose of this study was to clarify the kinematics of kneeling. Methods The subjects were 15 healthy young males. Kneeling activity was analysed within a knee flexion angle from 100° to maximum flexion (maxflex, mean ± SD = 161.3 ± 3.2°). The kinematic and contact point (CP) analyses were performed using a 2D/3D registration method, in which a 3D bone model created from computed tomography images was matched to knee lateral fluoroscopic images and analysed on a personal computer. Results In the kinematic analysis, the femur translated 37.5 mm posteriorly and rotated 19.8° externally relative to the tibia during the knee flexion phase. During the knee extension phase, the femur translated 36.4 mm anteriorly, which was almost the same amount as in the knee flexion phase. However, the femur rotated only 7.4° internally during the knee extension phase. In the CP analysis, the amount of anterior translation of the CP in the knee extension phase was greater in the medial CP and smaller in the lateral CP than that of posterior translation in the knee flexion phase. Conclusions In kneeling, there was a difference in the rotational kinematics between the flexion phase and the extension phase. The kinematic difference between the flexion and extension phases may have some effect on the meniscus and articular cartilage.
Collapse
|
16
|
Babel H, Omoumi P, Cosendey K, Stanovici J, Cadas H, Jolles BM, Favre J. An Expert-Supervised Registration Method for Multiparameter Description of the Knee Joint Using Serial Imaging. J Clin Med 2022; 11:548. [PMID: 35160002 PMCID: PMC8837137 DOI: 10.3390/jcm11030548] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2021] [Revised: 01/11/2022] [Accepted: 01/21/2022] [Indexed: 01/25/2023] Open
Abstract
As knee osteoarthritis is a disease of the entire joint, our pathophysiological understanding could be improved by the characterization of the relationships among the knee components. Diverse quantitative parameters can be characterized using magnetic resonance imaging (MRI) and computed tomography (CT). However, a lack of methods for the coordinated measurement of multiple parameters hinders global analyses. This study aimed to design an expert-supervised registration method to facilitate multiparameter description using complementary image sets obtained by serial imaging. The method is based on three-dimensional tissue models positioned in the image sets of interest using manually placed attraction points. Two datasets, with 10 knees CT-scanned twice and 10 knees imaged by CT and MRI were used to assess the method when registering the distal femur and proximal tibia. The median interoperator registration errors, quantified using the mean absolute distance and Dice index, were ≤0.45 mm and ≥0.96 unit, respectively. These values differed by less than 0.1 mm and 0.005 units compared to the errors obtained with gold standard methods. In conclusion, an expert-supervised registration method was introduced. Its capacity to register the distal femur and proximal tibia supports further developments for multiparameter description of healthy and osteoarthritic knee joints, among other applications.
Collapse
Affiliation(s)
- Hugo Babel
- Swiss BioMotion Lab, Lausanne University Hospital and University of Lausanne (CHUV-UNIL), CH-1011 Lausanne, Switzerland; (H.B.); (K.C.); (B.M.J.)
| | - Patrick Omoumi
- Service of Diagnostic and Interventional Radiology, Lausanne University Hospital and University of Lausanne (CHUV-UNIL), CH-1011 Lausanne, Switzerland;
- Department of Radiology, Cliniques Universitaires St Luc-UC Louvain, BE-1200 Brussels, Belgium
| | - Killian Cosendey
- Swiss BioMotion Lab, Lausanne University Hospital and University of Lausanne (CHUV-UNIL), CH-1011 Lausanne, Switzerland; (H.B.); (K.C.); (B.M.J.)
| | - Julien Stanovici
- Service of Orthopedics and Traumatology, Lausanne University Hospital and University of Lausanne (CHUV-UNIL), CH-1011 Lausanne, Switzerland;
| | - Hugues Cadas
- Unité Facultaire d’Anatomie et de Morphologie, University of Lausanne (UNIL), CH-1005 Lausanne, Switzerland;
| | - Brigitte M. Jolles
- Swiss BioMotion Lab, Lausanne University Hospital and University of Lausanne (CHUV-UNIL), CH-1011 Lausanne, Switzerland; (H.B.); (K.C.); (B.M.J.)
- Institute of Microengineering, Ecole Polytechnique Fédérale Lausanne (EPFL), CH-1015 Lausanne, Switzerland
| | - Julien Favre
- Swiss BioMotion Lab, Lausanne University Hospital and University of Lausanne (CHUV-UNIL), CH-1011 Lausanne, Switzerland; (H.B.); (K.C.); (B.M.J.)
| |
Collapse
|
17
|
Florkow MC, Willemsen K, Mascarenhas VV, Oei EHG, van Stralen M, Seevinck PR. Magnetic Resonance Imaging Versus Computed Tomography for Three-Dimensional Bone Imaging of Musculoskeletal Pathologies: A Review. J Magn Reson Imaging 2022; 56:11-34. [PMID: 35044717 PMCID: PMC9305220 DOI: 10.1002/jmri.28067] [Citation(s) in RCA: 63] [Impact Index Per Article: 21.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2021] [Revised: 12/31/2021] [Accepted: 01/05/2022] [Indexed: 12/18/2022] Open
Abstract
Magnetic resonance imaging (MRI) is increasingly utilized as a radiation‐free alternative to computed tomography (CT) for the diagnosis and treatment planning of musculoskeletal pathologies. MR imaging of hard tissues such as cortical bone remains challenging due to their low proton density and short transverse relaxation times, rendering bone tissues as nonspecific low signal structures on MR images obtained from most sequences. Developments in MR image acquisition and post‐processing have opened the path for enhanced MR‐based bone visualization aiming to provide a CT‐like contrast and, as such, ease clinical interpretation. The purpose of this review is to provide an overview of studies comparing MR and CT imaging for diagnostic and treatment planning purposes in orthopedic care, with a special focus on selective bone visualization, bone segmentation, and three‐dimensional (3D) modeling. This review discusses conventional gradient‐echo derived techniques as well as dedicated short echo time acquisition techniques and post‐processing techniques, including the generation of synthetic CT, in the context of 3D and specific bone visualization. Based on the reviewed literature, it may be concluded that the recent developments in MRI‐based bone visualization are promising. MRI alone provides valuable information on both bone and soft tissues for a broad range of applications including diagnostics, 3D modeling, and treatment planning in multiple anatomical regions, including the skull, spine, shoulder, pelvis, and long bones.
Collapse
Affiliation(s)
- Mateusz C Florkow
- Image Sciences Institute, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Koen Willemsen
- Department of Orthopedics, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Vasco V Mascarenhas
- Musculoskeletal Imaging Unit, Imaging Center, Hospital da Luz, Lisbon, Portugal
| | - Edwin H G Oei
- Department of Radiology and Nuclear Medicine, Erasmus MC, University Medical Center Rotterdam, Rotterdam, The Netherlands
| | - Marijn van Stralen
- Image Sciences Institute, University Medical Center Utrecht, Utrecht, The Netherlands.,MRIguidance BV, Utrecht, The Netherlands
| | - Peter R Seevinck
- Image Sciences Institute, University Medical Center Utrecht, Utrecht, The Netherlands.,MRIguidance BV, Utrecht, The Netherlands
| |
Collapse
|
18
|
Burton WS, Myers CA, Jensen A, Hamilton L, Shelburne KB, Banks SA, Rullkoetter PJ. Automatic tracking of healthy joint kinematics from stereo-radiography sequences. Comput Biol Med 2021; 139:104945. [PMID: 34678483 DOI: 10.1016/j.compbiomed.2021.104945] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2021] [Revised: 10/06/2021] [Accepted: 10/11/2021] [Indexed: 11/17/2022]
Abstract
Kinematic tracking of healthy joints in radiography sequences is frequently performed by maximizing similarities between computed perspective projections of 3D computer models and corresponding objects' appearances in radiographic images. Significant human effort associated with manual tracking presents a major bottleneck in biomechanics research methods and limits the scale of target applications. The current work introduces a method for fully-automatic tracking of tibiofemoral and patellofemoral kinematics in stereo-radiography sequences for subjects performing dynamic activities. The proposed method involves the application of convolutional neural networks for annotating radiographs and a multi-stage optimization pipeline for estimating bone pose based on information provided by neural net predictions. Predicted kinematics are evaluated by comparing against manually-tracked trends across 20 distinct trials. Median absolute differences below 1.5 millimeters or degrees for 6 tibiofemoral and 3 patellofemoral degrees of freedom demonstrate the utility of our approach, which improves upon previous semi-automatic methods by enabling end-to-end automation. Implementation of a fully-automatic pipeline for kinematic tracking will benefit evaluation of human movement by enabling large-scale studies of healthy knee kinematics.
Collapse
Affiliation(s)
- William S Burton
- Center for Orthopaedic Biomechanics at the University of Denver, 2155 E. Wesley Ave., Denver, CO, 80208, USA.
| | - Casey A Myers
- Center for Orthopaedic Biomechanics at the University of Denver, 2155 E. Wesley Ave., Denver, CO, 80208, USA.
| | - Andrew Jensen
- Department of Mechanical and Aerospace Engineering at the University of Florida, 939 Center Dr., Gainesville, FL, 32611, USA.
| | - Landon Hamilton
- Center for Orthopaedic Biomechanics at the University of Denver, 2155 E. Wesley Ave., Denver, CO, 80208, USA.
| | - Kevin B Shelburne
- Center for Orthopaedic Biomechanics at the University of Denver, 2155 E. Wesley Ave., Denver, CO, 80208, USA.
| | - Scott A Banks
- Department of Mechanical and Aerospace Engineering at the University of Florida, 939 Center Dr., Gainesville, FL, 32611, USA.
| | - Paul J Rullkoetter
- Center for Orthopaedic Biomechanics at the University of Denver, 2155 E. Wesley Ave., Denver, CO, 80208, USA.
| |
Collapse
|
19
|
Stephen JM, Calder JD, Williams A, El Daou H. Comparative accuracy of lower limb bone geometry determined using MRI, CT, and direct bone 3D models. J Orthop Res 2021; 39:1870-1876. [PMID: 33222265 DOI: 10.1002/jor.24923] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/05/2020] [Revised: 10/22/2020] [Accepted: 11/19/2020] [Indexed: 02/04/2023]
Abstract
Advancements in imaging and segmentation techniques mean that three dimensional (3D) modeling of bones is now increasingly used for preoperative planning and registration purposes. Computer tomography (CT) scans are commonly used due to their high bone-soft tissue contrast, however they expose subjects to radiation. Alternatively, magnetic resonance imaging (MRI) is radiation-free: however, geometric field distortion and poor bone contrast have been reported to degrade bone model validity compared to CT. The present study assessed the accuracy of 3D femur and tibia models created from "Black Bone" 3T MRI and high resolution CT scans taken from 12 intact cadaveric lower limbs by comparing them with scans of the de-fleshed and cleaned bones carried out using a high-resolution portable compact desktop 3D scanner (Model HDI COMPACT C210; Polyga). This scanner used structured light (SL) to capture 3D scans with an accuracy of up to 35 μm. Image segmentation created 3D models and for each bone the corresponding CT and MRI models were aligned with the SL model using the iterative closest point (ICP) algorithm and the differences between models calculated. Hausdorff distance was also determined. Compared to SL scans, the CT models had an ICP error of 0.82 ± 0.2 and 0.85 ± 0.2 mm for the tibia and femur respectively, whilst the MRI models had an error of 0.97 ± 0.2 and 0.98 ± 0.18 mm. A one-way analysis of variance found no significant difference in the Hausdorff distances or ICP values between the three scanning methods (p > .05). The black bone MRI method can provide accurate geometric measures of the femur and tibia that are comparable to those achieved with CT. Given the lack of ionizing radiation this has significant benefits for clinical populations and also potential for application in research settings.
Collapse
Affiliation(s)
- Joanna M Stephen
- Fortius Clinic, London, UK.,Department of Mechanical Engineering, Imperial College London, London, UK
| | - James Df Calder
- Fortius Clinic, London, UK.,Department of Bioengineering, Imperial College London, London, UK
| | - Andy Williams
- Fortius Clinic, London, UK.,Department of Mechanical Engineering, Imperial College London, London, UK
| | - Hadi El Daou
- Department of Mechanical Engineering, Imperial College London, London, UK
| |
Collapse
|
20
|
Shiode R, Kabashima M, Hiasa Y, Oka K, Murase T, Sato Y, Otake Y. 2D-3D reconstruction of distal forearm bone from actual X-ray images of the wrist using convolutional neural networks. Sci Rep 2021; 11:15249. [PMID: 34315946 PMCID: PMC8316567 DOI: 10.1038/s41598-021-94634-2] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2020] [Accepted: 05/06/2021] [Indexed: 01/08/2023] Open
Abstract
The purpose of the study was to develop a deep learning network for estimating and constructing highly accurate 3D bone models directly from actual X-ray images and to verify its accuracy. The data used were 173 computed tomography (CT) images and 105 actual X-ray images of a healthy wrist joint. To compensate for the small size of the dataset, digitally reconstructed radiography (DRR) images generated from CT were used as training data instead of actual X-ray images. The DRR-like images were generated from actual X-ray images in the test and adapted to the network, and high-accuracy estimation of a 3D bone model from a small data set was possible. The 3D shape of the radius and ulna were estimated from actual X-ray images with accuracies of 1.05 ± 0.36 and 1.45 ± 0.41 mm, respectively.
Collapse
Affiliation(s)
- Ryoya Shiode
- Department of Orthopaedic Surgery, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita, Osaka, 565-0871, Japan. .,Division of Information Science, Nara Institute of Science and Technology, 8916-5 Takayama, Ikoma, Nara, 630-0192, Japan.
| | - Mototaka Kabashima
- Division of Information Science, Nara Institute of Science and Technology, 8916-5 Takayama, Ikoma, Nara, 630-0192, Japan
| | - Yuta Hiasa
- Division of Information Science, Nara Institute of Science and Technology, 8916-5 Takayama, Ikoma, Nara, 630-0192, Japan
| | - Kunihiro Oka
- Department of Orthopaedic Surgery, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita, Osaka, 565-0871, Japan
| | - Tsuyoshi Murase
- Department of Orthopaedic Surgery, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita, Osaka, 565-0871, Japan
| | - Yoshinobu Sato
- Division of Information Science, Nara Institute of Science and Technology, 8916-5 Takayama, Ikoma, Nara, 630-0192, Japan
| | - Yoshito Otake
- Division of Information Science, Nara Institute of Science and Technology, 8916-5 Takayama, Ikoma, Nara, 630-0192, Japan.
| |
Collapse
|
21
|
C Millar S, Arnold JB, B Solomon L, Thewlis D, Fraysse F. Development and evaluation of a method to define a tibial coordinate system through the fitting of geometric primitives. Int Biomech 2021; 8:12-18. [PMID: 33998376 PMCID: PMC8130718 DOI: 10.1080/23335432.2021.1916406] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/02/2022] Open
Abstract
Coordinate system definition is a critical element of biomechanical modeling of the knee, and cases of skeletal trauma present major technical challenges. This paper presents a method to define a tibial coordinate system by fitting geometric primitives to surface anatomy requiring minimal user input. The method presented here utilizes a conical fit to both the tibial shaft and femoral condyles to generate independent axes forming the basis of a tibial coordinate system. Definition of the tibial axis showed high accuracy when shape fitting to ≥50 mm of shaft with <3° of angular variation from the axis obtained using the full tibia. Repeatability and reproducibility of the axis was compared using intraclass correlation coefficients which showed excellent intra- and inter-observer agreement across cases. Additionally, shape fitting to the distal femoral condyles showed high accuracy compared to the reference axis established automatically through identifying the medial and lateral epicondyles (<4°). Utilizing geometric primitives to estimate functional axes for the tibia and femur removes reliance on anatomical landmarks that can be displaced by fracture or inaccurately identified by observers. Furthermore, fitting of such primitives provides a more complete understanding of the true bony anatomy, which cannot be done through simple landmark identification.
Collapse
Affiliation(s)
- Stuart C Millar
- Centre for Orthopaedic and Trauma Research, The University of Adelaide, Adelaide, SA, Australia.,Alliance for Research in Exercise, Nutrition and Activity (ARENA), School of Health Sciences, University of South Australia, Adelaide, SA, Australia
| | - John B Arnold
- Innovation, Implementation and Clinical Translation in Health (IIMPACT), University of South Australia, Adelaide, SA, Australia
| | - Lucian B Solomon
- Centre for Orthopaedic and Trauma Research, The University of Adelaide, Adelaide, SA, Australia.,Department of Orthopaedics and Trauma, Royal Adelaide Hospital, Adelaide, SA, Australia
| | - Dominic Thewlis
- Centre for Orthopaedic and Trauma Research, The University of Adelaide, Adelaide, SA, Australia
| | - François Fraysse
- Alliance for Research in Exercise, Nutrition and Activity (ARENA), School of Health Sciences, University of South Australia, Adelaide, SA, Australia
| |
Collapse
|
22
|
Su P, Zhou JL, Liu F, Zhang Y. Application of Image Registration to Analyze the Clavicular Rotation of Normal Upper Limb Motion in the Sagittal Plane. Orthop Surg 2021; 13:493-500. [PMID: 33569907 PMCID: PMC7957416 DOI: 10.1111/os.12941] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/29/2020] [Revised: 12/24/2020] [Accepted: 12/30/2020] [Indexed: 11/30/2022] Open
Abstract
OBJECTIVE To use image registration techniques to study the clavicular rotation of the shoulders in the sagittal plane. METHODS From 28 April 2019 to 20 May 2019, 13 healthy adults (7 males and 6 females) with no history of shoulder trauma surgery or chronic pain were recruited. Patients' ages ranged from 22 to 42 years, with a mean age of 26.5 years. Three-dimensional composite images of the sternum-clavicle-humerus were taken using CT images of upper limb movement in the sagittal plane in the 13 healthy adults. Four different postures were registered: (i) anatomical supine position; (ii) elbow joints lifted anteriorly in the supine position; (iii) posterosuperior hyperextension of the elbow joints in the prone position; and (iv) posteroinferior hyperextension of the elbow joints in the prone position. Image data from the humerus and clavicle in three of the postures were processed to calculate Euler angles for movements in the sagittal plane. SPSS 19 was used to perform statistical analyses. RESULTS There was no significant difference in the angles of change in the clavicle and humerus between the dominant and non-dominant sides under different movement patterns. For upper limb movements in the sagittal plane, the clavicle displayed different Euler angles in different postures. The rotation angle from the anatomical to the horizontal position was the smallest angle, with an average value of 7.1°, whereas the rotation angle from horizontal to posterosuperior hyperextension was the largest, with an average value of 37.2°. When the upper limb moved from anterior protraction to a posterosuperior extension, the intrinsic rotation angle of the clavicle reached its maximum, with an average value of 27.9°; when moved from the anatomical to the horizontal position, 9.1% of the sagittal rotation was executed by the clavicle. During rotation from the horizontal position to posterosuperior hyperextension and from the anatomical to posterior extension, the clavicle showed relatively higher weights at 29.5% and 37.0%, respectively. CONCLUSION Our results showed that dominance was not a consideration when studying clavicular rotation. Image registration is an effective method that can be used to study upper limb scapular movements. Through comparing and analyzing the data, two postures had relatively large changes in the rotation angle. This can help improve indicators of clavicular rotational function during physical examinations and postoperative functional evaluations.
Collapse
Affiliation(s)
- Peng Su
- Department of Orthopaedics, Beijing Chaoyang Hospital, Capital Medical University, Beijing, China.,Department of Orthopaedics, Beijing Shijingshan Hospital, Capital Medical University, Beijing, China
| | - Jun-Lin Zhou
- Department of Orthopaedics, Beijing Chaoyang Hospital, Capital Medical University, Beijing, China
| | - Feng Liu
- Department of Orthopaedics, Beijing Shijingshan Hospital, Capital Medical University, Beijing, China
| | - Yi Zhang
- Department of Orthopaedics, Beijing Shijingshan Hospital, Capital Medical University, Beijing, China
| |
Collapse
|
23
|
Nicolet-Petersen S, Saiz A, Shelton T, Howell SM, Hull ML. Small differences in tibial contact locations following kinematically aligned TKA from the native contralateral knee. Knee Surg Sports Traumatol Arthrosc 2020; 28:2893-2904. [PMID: 31410525 DOI: 10.1007/s00167-019-05658-1] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/31/2019] [Accepted: 08/02/2019] [Indexed: 10/26/2022]
Abstract
PURPOSE Kinematically aligned (KA) TKA strives to restore native limb and knee alignments without ligament release with the premise that knee function likewise will be closely restored to native to the extent enabled by the components used. This study determined differences in anterior-posterior (AP) tibial contact locations of a KA TKA performed with asymmetric, fixed bearing, posterior cruciate-retaining (PCR) components from those of the native contralateral knee and also determined the incidence of posterior rim contact of the tibial insert during a deep knee bend and a step-up. METHODS Both knees were imaged using single-plane fluoroscopy for 25 patients with a calipered KA TKA and a native knee in the contralateral limb. AP tibial contact locations in each compartment were determined following 3D model-to-2D image registration. Differences in mean AP tibial contact locations in each compartment between the KA TKA knees and the native contralateral knees were analysed. Contact locations either on or beyond the most posterior point of the tibial insert determined the occurrence of posterior rim contact. RESULTS Mean AP tibial contact locations for both native and KA TKA knees remained relatively centred in the medial compartment but moved posterior in the lateral compartment during flexion. In both the medial and lateral compartments, differences in mean AP tibial contact locations between the KA TKA knees and the native contralateral knees were more posterior and greatest at 0° flexion for both activities (4 mm, p = 0.0009 and 7 mm, p < 0.0001 for deep knee bend and 6 mm, p < 0.0001 and 8 mm, p < 0.0001 for step-up in the medial and lateral compartments, respectively). The incidence of posterior rim contact of the tibial insert was 16% (4 of 25 patients) but the lowest Oxford Knee Score was 43 for these patients. The median Oxford Knee Score for all patients was 46 (out of 48). CONCLUSIONS Calipered KA TKA with asymmetric, fixed bearing, PCR components resulted in mean AP tibial contact locations which were relatively centred in the compartments and differed at most from those of the native contralateral knee by approximately 15% of the AP dimension of a mid-sized tibial baseplate. Although posterior rim contact occurred in some patients, all such patients had high patient-reported outcome scores. LEVEL OF EVIDENCE Therapeutic, Level III.
Collapse
Affiliation(s)
- Stephanie Nicolet-Petersen
- Department of Biomedical Engineering, University of California Davis, One Shields Avenue, Davis, CA, 95616, USA
| | - Augustine Saiz
- Department of Orthopaedic Surgery, University of California Davis Medical Center, 4860 Y Street, Suite 3800, Sacramento, CA, 95817, USA
| | - Trevor Shelton
- Department of Orthopaedic Surgery, University of California Davis Medical Center, 4860 Y Street, Suite 3800, Sacramento, CA, 95817, USA
| | - Stephen M Howell
- Department of Biomedical Engineering, University of California Davis, One Shields Avenue, Davis, CA, 95616, USA
| | - Maury L Hull
- Department of Biomedical Engineering, University of California Davis, One Shields Avenue, Davis, CA, 95616, USA. .,Department of Orthopaedic Surgery, University of California Davis Medical Center, 4860 Y Street, Suite 3800, Sacramento, CA, 95817, USA. .,Department of Mechanical Engineering, University of California Davis, One Shields Avenue, Davis, CA, 95616, USA.
| |
Collapse
|
24
|
Ikuta F, Yoneta K, Miyaji T, Kidera K, Yonekura A, Osaki M, Gamada K. Knee kinematics of severe medial knee osteoarthritis showed tibial posterior translation and external rotation: a cross-sectional study. Aging Clin Exp Res 2020; 32:1767-1775. [PMID: 31598915 DOI: 10.1007/s40520-019-01361-w] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2019] [Accepted: 09/21/2019] [Indexed: 12/17/2022]
Abstract
BACKGROUND Knee osteoarthritis (OA) gradually reduces knee function and limits activities of daily living with age. However, the progression of abnormal kinematics of the knee in knee OA is unclear. AIMS This study aimed to clarify the relationship between stage of knee OA and abnormal knee kinematics and to identify a strategy for prevention of knee OA. METHODS A total of 112 knees of 99 patients (45 men/54 women; 55.9 ± 18.2 years), comprising 28 (27/1) in Kellgren-Lawrence grade 0, 18 (8/10) in grade 1, 27 (2/25) in grade 2, 28 (6/22) in grade 3, and 11 (3/8) in grade 4, were enrolled in this cross-sectional study. In vivo knee kinematics was obtained using a three-dimensional-to-two-dimensional registration technique utilizing CT-based bone models and lateral fluoroscopy during knee extension-flexion in an upright sitting position and squatting. RESULTS The external rotation angle of the tibia relative to the femur was greater in grade 3/4 knees than in grade 0/1 knees and tibial posterior translation was greater in grade 3/4 knees than in grade 0-2 knees. DISCUSSION Age-related changes in muscle activity and joint instability are considered to be the cause of these abnormal kinematics. CONCLUSIONS As the stage of knee OA progresses, there was a tendency toward increasing tibial external rotation and tibial posterior translation during knee extension-flexion in sitting position and squatting. Prevention of the progress of the abnormal knee kinematics may prevent the progression of the knee OA.
Collapse
Affiliation(s)
- Futoshi Ikuta
- Department Medical Engineering and Technology, Graduate School of Medical Technology and Health Welfare Sciences, Hiroshima International University, 555-36 Kurosegakuendai, Higashihiroshima-shi, Hiroshima-ken, 739-2695, Japan.
- Inanami Spine and Joint Hospital, 3-17-5 Higashishinagawa, Shinagawa-ku, Tokyo, 140-0002, Japan.
| | - Kei Yoneta
- Department of Rehabilitation, Kobayashi Hospital, Kita 3 Jo Nishi 4-chome, Kitami-shi, Hokkaido, 090-0043, Japan
| | - Takeshi Miyaji
- Department of Orthopaedic Surgery, Aino Memorial Hospital, 3838-1 Ainomachiotsu, Unzen-shi, Nagasaki-ken, 854-0301, Japan
| | - Kenichi Kidera
- Department of Orthopaedic Surgery, Graduate School of Biomedical Sciences, Nagasaki University, 1-7-1 Sakamoto, Nagasaki-shi, Nagasaki-ken, 852-8501, Japan
| | - Akihiko Yonekura
- Department of Orthopaedic Surgery, Graduate School of Biomedical Sciences, Nagasaki University, 1-7-1 Sakamoto, Nagasaki-shi, Nagasaki-ken, 852-8501, Japan
| | - Makoto Osaki
- Department of Orthopaedic Surgery, Graduate School of Biomedical Sciences, Nagasaki University, 1-7-1 Sakamoto, Nagasaki-shi, Nagasaki-ken, 852-8501, Japan
| | - Kazuyoshi Gamada
- Department Medical Engineering and Technology, Graduate School of Medical Technology and Health Welfare Sciences, Hiroshima International University, 555-36 Kurosegakuendai, Higashihiroshima-shi, Hiroshima-ken, 739-2695, Japan
| |
Collapse
|
25
|
Kim D, Lee B, Yeom J, Cha J, Han J. Three-dimensional in vivo comparative analysis of the kinematics of normal shoulders and shoulders with massive rotator cuff tears with successful conservative treatment. Clin Biomech (Bristol, Avon) 2020; 75:104990. [PMID: 32222472 DOI: 10.1016/j.clinbiomech.2020.104990] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/01/2019] [Revised: 03/11/2020] [Accepted: 03/12/2020] [Indexed: 02/07/2023]
Abstract
BACKGROUND This study used in vivo three-dimensional to two-dimensional image registration techniques to compare the glenohumeral kinematics of shoulders with massive rotator cuff tears that were successfully treated conservatively and those of normal shoulders. METHODS Ten patients (age, 67.4 ± 3.63 years) with massive rotator cuff tears on one side and without contralateral tears were enrolled. We performed computed tomography and fluoroscopy on both shoulder joints and created three-dimensional bone models of the humerus and scapula using image registration techniques. We measured the humeral superoinferior translation, angle of humeral external rotation, scapular upward rotation, scapular anteroposterior tilt, and scapular external rotation of the torn shoulders with good range of motion after effective conservative treatment and compared these measurements to those of the contralateral normal shoulders. FINDINGS There was a significant difference in the initial position of the humeral head relative to the glenoid in the tear group; it was 2.0 mm higher than that in the normal group (p < .05). This difference disappeared in the range from 40° to full elevation. The scapular motion of the tear group was significantly more upwardly rotated than that of the normal group: by 9.9° at rest (p < .05) and by 11.6° at terminal elevation (p < .05). No significant differences were detected for humeral head external rotation, scapular anteroposterior tilt, and scapular external rotation between the two groups. INTERPRETATION Kinematics of shoulders with massive cuff tears could not be recovered completely even though the patients had no significant symptoms after successful conservative treatment.
Collapse
Affiliation(s)
- Doosup Kim
- Department of Orthopaedic Surgery, Wonju College of Medicine, Yonsei University, Wonju Severance Christian Hospital, Republic of Korea.
| | - Bonggun Lee
- Department of Orthopedic Surgery, Hanyang University, Seoul, Republic of Korea.
| | - Junseop Yeom
- Department of Orthopaedic Surgery, Wonju College of Medicine, Yonsei University, Wonju Severance Christian Hospital, Republic of Korea
| | - Jaehack Cha
- Department of Orthopaedic Surgery, Wonju College of Medicine, Yonsei University, Wonju Severance Christian Hospital, Republic of Korea
| | - Jinyoung Han
- Department of Orthopaedic Surgery, Wonju College of Medicine, Yonsei University, Wonju Severance Christian Hospital, Republic of Korea
| |
Collapse
|
26
|
Tibiofemoral kinematics in healthy and osteoarthritic knees during twisting. J Orthop 2020; 21:213-217. [PMID: 32273659 DOI: 10.1016/j.jor.2020.03.051] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/16/2020] [Accepted: 03/26/2020] [Indexed: 11/22/2022] Open
Abstract
Purpose The purpose of this study was to determine the in vivo kinematics of healthy knees and those with osteoarthritis (OA), during twisting using density-based image-matching techniques. Methods Five healthy subjects and 26 patients with medial knee OA performed twisting under periodic X-ray imaging. Results The tibiofemoral rotation at the ipsilateral/contralateral twist in healthy and OA knees were 11° ± 9.3° externally/9.5° ± 5.6° internally (p < 0.05) and 4.4° ± 7.2° externally/2.7° ± 8° internally (p < 0.05), respectively. Conclusions The kinematic analysis of OA knees during twisting revealed significantly smaller tibiofemoral rotation than those of healthy knees.
Collapse
|
27
|
Hoshi K, Watanabe G, Kurose Y, Tanaka R, Fujii J, Gamada K. Mobile-bearing insert used with total knee arthroplasty does not rotate on the tibial tray during a squatting activity: a cross-sectional study. J Orthop Surg Res 2020; 15:114. [PMID: 32197628 PMCID: PMC7085202 DOI: 10.1186/s13018-020-1570-6] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/09/2019] [Accepted: 01/23/2020] [Indexed: 11/25/2022] Open
Abstract
Background Total knee arthroplasty (TKA) is commonly performed around the world. Implant designs include fixed-bearing and mobile-bearing. Mobile-bearing design was developed as a rotating platform that allows axial rotation of the insert around the longitudinal axis. This phenomenon may limit full exploitation of the characteristics of the mobile-bearing insert, which may cause wearing and reduce longevity. However, there is limited knowledge on rotational behavior of the polyethylene mobile-bearing insert under weight-bearing conditions. We aimed at determining the rotational motion of each component at full extension and flexed positions during a squatting activity after TKA. Methods This study was a cross-sectional study (level 4) involving patients with severe knee osteoarthritis scheduled to receive TKA. We examined 13 knees of 11 patients after mobile-bearing TKA (NexGen LPS-Flex, Zimmer Inc.) at 10 weeks and 1 year postoperatively. Four identical metallic beads were embedded into the insert. Wide-base squatting was chosen for analyses. Three-dimensional in vivo poses of the prostheses were created using a 3D-to-2D registration technique. During flexion, rotation of the femoral component relative to the insert (FEM/INS) and tibial component (FEM/TIB) as well as insert rotation relative to the tibial component (INS/TIB) were computed. Repeated measure 2-way ANOVA and post hoc test was used. Results In the fully extended position, FEM/INS was significantly smaller than INS/TIB both at 10 weeks (− 0.3° vs. 6.3°, p = .013) and 1 year (− 0.8° vs. 4.9°, p = .011), respectively. During the squatting activity, rotation motions of FEM/TIB, FEM/INS, INS/TIB were 5.7°, 5.9°, and 1.8° at 10 weeks and 6.3°, 5.5°, and 1.6° at 1 year, respectively. Rotation motion of FEM/INS was significantly greater than that of INS/TIB at both 10 weeks (p < .001) and 1 year (p < .001). Conclusions The mobile-bearing insert enhances the compatibility of FEM/INS in extension; the amount of INS/TIB rotation is significantly smaller than that of FEM/INS during a squatting activity. This information will inform surgeons to take caution to perform TKA with a fixed insert in which 6.3° of rotational offset would be added to the rotational alignment at FEM/INS at full extension. Trial registration UMIN-CTR, UMIN000024196. Retrospectively registered on 9 September 2016.
Collapse
Affiliation(s)
- Kenji Hoshi
- Graduate School of Medical Technology and Health Welfare Sciences, Hiroshima International University, 555-36 Kurose-Gakuendai, Bldg3, Rm3807, Higashi-Hiroshima, Hiroshima, 739-2695, Japan
| | - Goro Watanabe
- Graduate School of Medical Technology and Health Welfare Sciences, Hiroshima International University, 555-36 Kurose-Gakuendai, Bldg3, Rm3807, Higashi-Hiroshima, Hiroshima, 739-2695, Japan
| | - Yasuo Kurose
- Hiroshima Prefectural Rehabilitation Center, 295-3 Taguchi, Saijo-cho, Higashi-Hiroshima, Hiroshima, 739-0036, Japan
| | - Ryuji Tanaka
- Hiroshima Prefectural Rehabilitation Center, 295-3 Taguchi, Saijo-cho, Higashi-Hiroshima, Hiroshima, 739-0036, Japan
| | - Jiro Fujii
- Hiroshima Prefectural Rehabilitation Center, 295-3 Taguchi, Saijo-cho, Higashi-Hiroshima, Hiroshima, 739-0036, Japan
| | - Kazuyoshi Gamada
- Graduate School of Medical Technology and Health Welfare Sciences, Hiroshima International University, 555-36 Kurose-Gakuendai, Bldg3, Rm3807, Higashi-Hiroshima, Hiroshima, 739-2695, Japan.
| |
Collapse
|
28
|
Koh YG, Park KM, Lee HY, Park JH, Kang KT. Prediction of wear performance in femoral and tibial conformity in patient-specific cruciate-retaining total knee arthroplasty. J Orthop Surg Res 2020; 15:24. [PMID: 31969195 PMCID: PMC6977248 DOI: 10.1186/s13018-020-1548-4] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/19/2019] [Accepted: 01/06/2020] [Indexed: 11/14/2022] Open
Abstract
BACKGROUND Articular surface curvature design is important in tibiofemoral kinematics and the contact mechanics of total knee arthroplasty (TKA). Thus far, the effects of articular surface curvature have not been adequately discussed with respect to conforming, nonconforming, and medial pivot designs in patient-specific TKA. Therefore, this study evaluates the underlying relationship between the articular surface curvature geometry and the wear performance in patient-specific TKA. METHODS We compare the wear performances between conventional and patient-specific TKA under gait loading conditions using a computational simulation. Patient-specific TKAs investigated in the study are categorized into patient-specific TKA with conforming articular surfaces, medial pivot patient-specific TKA, and bio-mimetic patient-specific TKA with a patient's own tibial and femoral anatomy. The geometries of the femoral components in patient-specific TKAs are identical. RESULTS The anterior-posterior and internal-external kinematics change with respect to different TKA designs. Moreover, the contact pressure and area did not directly affect the wear performance. In particular, conforming patient-specific TKAs exhibit the highest volumetric wear and wear rate. The volumetric wear in a conforming patient-specific TKA is 29% greater than that in a medial pivot patient-specific TKA. CONCLUSION The findings in this study highlight that conformity changes in the femoral and tibial inserts influence the wear performance in patient-specific TKA. Kinematics and contact parameters should be considered to improve wear performance in patient-specific TKA. The conformity modification in the tibiofemoral joint changes the kinematics and contact parameters, and this affects wear performance.
Collapse
Affiliation(s)
- Yong-Gon Koh
- Joint Reconstruction Center, Department of Orthopaedic Surgery, Yonsei Sarang Hospital, 10 Hyoryeong-ro, Seocho-gu, Seoul, 06698, Republic of Korea
| | - Kyoung-Mi Park
- Department of Mechanical Engineering, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea
| | - Hwa-Yong Lee
- Department of Mechanical Engineering, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea
| | - Joon-Hee Park
- Department of Anesthesiology & Pain Medicine, Hallym University College of Medicine and Kangdong Sacred Heart Hospital, 150 Seongan-ro, Gangdong-gu, Seoul, 05355, Republic of Korea.
| | - Kyoung-Tak Kang
- Department of Mechanical Engineering, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea.
| |
Collapse
|
29
|
Postolka B, List R, Thelen B, Schütz P, Taylor WR, Zheng G. Evaluation of an intensity-based algorithm for 2D/3D registration of natural knee videofluoroscopy data. Med Eng Phys 2020; 77:107-113. [PMID: 31980316 DOI: 10.1016/j.medengphy.2020.01.002] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2019] [Revised: 09/24/2019] [Accepted: 01/07/2020] [Indexed: 10/25/2022]
Abstract
The accurate quantification of in-vivo tibio-femoral kinematics is essential for understanding joint functionality, but determination of the 3D pose of bones from 2D single-plane fluoroscopic images remains challenging. We aimed to evaluate the accuracy, reliability and repeatability of an intensity-based 2D/3D registration algorithm. The accuracy was evaluated using fluoroscopic images of 2 radiopaque bones in 18 different poses, compared against a gold-standard fiducial calibration device. In addition, 3 natural femora and 3 natural tibiae were used to examine registration reliability and repeatability. Both manual fitting and intensity-based registration exhibited a mean absolute error of <1 mm in-plane. Overall, intensity-based registration of the femoral bone model revealed significantly higher translational and rotational errors than manual fitting, while no statistical differences (except for y-axis translation) were found for the tibial bone model. The repeatability of 108 intensity-based registrations showed mean in-plane standard deviations of 0.23-0.56 mm, but out-of-plane position repeatability was lower (mean SD: femur 7.98 mm, tibia 6.96 mm). SDs for rotations averaged 0.77-2.52°. While the algorithm registered some images extremely well, other images clearly required manual intervention. When the algorithm registered the bones repeatably, it was also accurate, suggesting an approach that includes manual intervention could become practical for efficient and accurate registration.
Collapse
Affiliation(s)
- Barbara Postolka
- ETH Zürich, Institute for Biomechanics, Leopold-Ruzicka-Weg 4, 8093 Zürich, Switzerland.
| | - Renate List
- ETH Zürich, Institute for Biomechanics, Leopold-Ruzicka-Weg 4, 8093 Zürich, Switzerland.
| | - Benedikt Thelen
- University of Berne, Institute for Surgical Technology & Biomechanics, Stauffacherstrasse 78, 3014 Bern, Switzerland.
| | - Pascal Schütz
- ETH Zürich, Institute for Biomechanics, Leopold-Ruzicka-Weg 4, 8093 Zürich, Switzerland.
| | - William R Taylor
- ETH Zürich, Institute for Biomechanics, Leopold-Ruzicka-Weg 4, 8093 Zürich, Switzerland.
| | - Guoyan Zheng
- University of Berne, Institute for Surgical Technology & Biomechanics, Stauffacherstrasse 78, 3014 Bern, Switzerland.
| |
Collapse
|
30
|
Watanabe G, Hoshi K, Kurose Y, Gamada K. High validity of measuring the width and volume of medial meniscal extrusion three-dimensionally using an MRI-derived tibial model. J Exp Orthop 2020; 7:1. [PMID: 31900597 PMCID: PMC6942059 DOI: 10.1186/s40634-019-0216-2] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/29/2019] [Accepted: 12/13/2019] [Indexed: 11/24/2022] Open
Abstract
BACKGROUND Medial meniscal extrusion (MME) is an important marker of knee osteoarthritis (KOA) progression. The purposes of this study were: 1) to determine whether there are morphological differences between CT- and MRI-derived tibial plateau models; and 2) to determine whether measurement of MME volume and width using an MRI-derived tibial model is as accurate as measurements on a CT-derived tibial model. METHODS This was a cross-sectional study that enrolled ten participants with medial KOA (Kellgren-Lawrence grade 1 to 3). Primary outcome was surface difference of the medial tibial plateau between CT- and MRI-derived models. Furthermore, volume and cross-sectional area of the medial tibial plateau were compared between CT- and MRI-derived models. Measurements of MME volume and width were compared between CT- and MRI-derived tibial models. RESULTS Minimal and maximal surface differences of the medial tibial plateau between the CT- and MRI-derived models were - 0.15 [- 0.44, 0.14] mm (mean [95% confidence interval]) and 0.24 [- 0.09, 0.57] mm, respectively. There were no significant differences in volume and cross-sectional area of the medial tibial plateau between CT- and MRI-derived tibial models. The MME volumes measured on CT- and MRI-derived models were 942.6 [597.7, 1287.6] mm3 and 916.2 [557.9, 1274.6] mm3, respectively (p = 0.938). The MME widths measured on CT- and MRI-derived models were 4.2 [1.9, 6.5] mm and 4.5 [2.2, 6.9] mm, respectively (p = 0.967). CONCLUSIONS CT- and MRI-derived models of the medial tibial plateau did not show significant morphological differences. Both CT- and MRI-derived tibia can be used as a reference to measure MME in early-to-moderate medial KOA.
Collapse
Affiliation(s)
- Goro Watanabe
- Graduate School of Medical Technology and Health Welfare Sciences, Hiroshima International University, 555-36 Kurosegakuendai, Higashihiroshima City, Hiroshima, Japan
| | - Kenji Hoshi
- Graduate School of Medical Technology and Health Welfare Sciences, Hiroshima International University, 555-36 Kurosegakuendai, Higashihiroshima City, Hiroshima, Japan
| | - Yasuo Kurose
- Department of Orthopaedics, Hiroshima Prefectural Rehabilitation Center, 295-3 Taguchi Saijo-cho, Higashihiroshima City, Hiroshima, Japan
| | - Kazuyoshi Gamada
- Graduate School of Medical Technology and Health Welfare Sciences, Hiroshima International University, 555-36 Kurosegakuendai, Higashihiroshima City, Hiroshima, Japan.
| |
Collapse
|
31
|
Osaki K, Hamai S, Okazaki K, Tashiro Y, Iwamoto Y. Preoperative 3-D MRI planning of tunnel placement in ACL reconstruction for a skeletally immature patient: A case report. J Orthop Sci 2019; 24:1144-1148. [PMID: 28576297 DOI: 10.1016/j.jos.2017.05.011] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/25/2016] [Revised: 05/06/2017] [Accepted: 05/15/2017] [Indexed: 10/19/2022]
Affiliation(s)
- Kanji Osaki
- Department of Orthopaedic Surgery, Faculty of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582, Japan
| | - Satoshi Hamai
- Department of Orthopaedic Surgery, Faculty of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582, Japan.
| | - Ken Okazaki
- Department of Orthopaedic Surgery, Faculty of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582, Japan
| | - Yasutaka Tashiro
- Department of Orthopaedic Surgery, Faculty of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582, Japan
| | - Yukihide Iwamoto
- Department of Orthopaedic Surgery, Faculty of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582, Japan
| |
Collapse
|
32
|
Ikuta F, Takahashi K, Hashimoto S, Mochizuki Y, Yuzawa Y, Inanami H, Takai S. Effect of physical therapy on early knee osteoarthritis with medial meniscal posterior tear assessed by MRI T2 mapping and 3D-to-2D registration technique: A prospective intervention study. Mod Rheumatol 2019; 30:738-747. [PMID: 31322024 DOI: 10.1080/14397595.2019.1646193] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
Objectives: The purpose of this study was to verify that exercise aimed at improving knee kinematics in early-stage knee osteoarthritis (OA) patients with medial meniscus posterior root tears (MMPRTs) reduces knee adduction angle during gait and prevents rapid cartilage degeneration in the medial compartment of the knee.Methods: Subjects were randomly assigned to an adapting alignment exercise (AAE) group, with the goal of improving knee kinematics, and a muscle training and exercise (MTE) group. Before the start of the six-month intervention and following its completion, we performed an analysis of knee kinematics during gait using a 3D-to-2D registration technique and identified the area of cartilage degeneration using MRI T2 mapping.Results: The amount of change between pre- and post-intervention measurements of the maximum angle of adduction was 0.48° (95% CI: -0.14, 1.09) in the MTE group and -0.40° (-0.84, 0.04) in the AAE group (p = .039). The amount of change in the area of cartilage degeneration according to MRI T2 mapping expressed as MTE/AAE group was 7.7 mm2 (-0.4, 15.8)/-2.7 mm2 (-10.8, 5.3) at the posterior knee (p = .043).Conclusion: AAE could be a potential treatment method that improves the natural course of knee OA with MMRPTs.
Collapse
Affiliation(s)
- Futoshi Ikuta
- Department of Orthopedic Surgery, Nippon Medical School, Tokyo, Japan.,Inanami Spine and Joint Hospital, Tokyo, Japan
| | - Kenji Takahashi
- Department of Orthopaedic Surgery, International University of Health and Welfare Hospital, Tochigi, Japan
| | | | - Yusuke Mochizuki
- Department of Orthopedic Surgery, Nippon Medical School, Tokyo, Japan
| | | | | | - Shinro Takai
- Department of Orthopedic Surgery, Nippon Medical School, Tokyo, Japan
| |
Collapse
|
33
|
In vivo dynamic acromiohumeral distance in shoulders with rotator cuff tears. Clin Biomech (Bristol, Avon) 2018; 60:95-99. [PMID: 30340151 DOI: 10.1016/j.clinbiomech.2018.07.017] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/15/2017] [Revised: 07/21/2018] [Accepted: 07/25/2018] [Indexed: 02/07/2023]
Abstract
BACKGROUND There are no previous studies on the acromiohumeral distance in shoulders with large-to-massive full-thickness rotator cuff tears. In this study, the acromiohumeral distance in rotator cuff tear and healthy shoulders was measured using 3D-to-2D model-to-image registration techniques. METHODS The dynamic glenohumeral kinematics during scapular plane abduction and axial rotation were analyzed in 11 rotator cuff tear patients and 10 healthy control subjects. Periodic radiographic images of scapular plane abduction and axial rotation were taken using a flat-panel radiograph image detector. Movements of the shoulder joint were assessed using radiographic images and computed tomography-derived digitally reconstructed radiographs. The acromiohumeral distance was defined as the shortest 3D distance between the acromion and the proximal humerus. FINDINGS For scapular plane abduction, the rotator cuff tear group had significantly smaller acromiohumeral distance than the control group at 15°, 30°, 45°, 60°, 75°, 135°, and 150° of humeral abduction (P < 0.05 at each measured angle). For axial rotation in the adducted position, the rotator cuff tear group had significantly smaller acromiohumeral distance than the control group at each point between -20° and 40° of glenohumeral external rotation (P < 0.05 at each measured angle). INTERPRETATION The minimum measured acromiohumeral distance was 0.9 mm in the rotator cuff tear shoulders and 2.1 mm in the healthy shoulders at 90° of scapular plane abduction. The findings are of clinical relevance because quantitative evaluation of the dynamic acromiohumeral distances in rotator cuff tear and healthy shoulders might provide important insight into subacromial impingement.
Collapse
|
34
|
Fukano M, Fukubayashi T, Banks SA. Sex differences in three-dimensional talocrural and subtalar joint kinematics during stance phase in healthy young adults. Hum Mov Sci 2018; 61:117-125. [DOI: 10.1016/j.humov.2018.06.003] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2017] [Revised: 04/19/2018] [Accepted: 06/01/2018] [Indexed: 11/29/2022]
|
35
|
Akbari-Shandiz M, Lawrence RL, Ellingson AM, Johnson CP, Zhao KD, Ludewig PM. MRI vs CT-based 2D-3D auto-registration accuracy for quantifying shoulder motion using biplane video-radiography. J Biomech 2018; 82:375-380. [PMID: 30385001 DOI: 10.1016/j.jbiomech.2018.09.019] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2018] [Revised: 09/21/2018] [Accepted: 09/24/2018] [Indexed: 10/28/2022]
Abstract
Biplane 2D-3D registration approaches have been used for measuring 3D, in vivo glenohumeral (GH) joint kinematics. Computed tomography (CT) has become the gold standard for reconstructing 3D bone models, as it provides high geometric accuracy and similar tissue contrast to video-radiography. Alternatively, magnetic resonance imaging (MRI) would not expose subjects to radiation and provides the ability to add cartilage and other soft tissues to the models. However, the accuracy of MRI-based 2D-3D registration for quantifying glenohumeral kinematics is unknown. We developed an automatic 2D-3D registration program that works with both CT- and MRI-based image volumes for quantifying joint motions. The purpose of this study was to use the proposed 2D-3D auto-registration algorithm to describe the humerus and scapula tracking accuracy of CT- and MRI-based registration relative to radiostereometric analysis (RSA) during dynamic biplanar video-radiography. The GH kinematic accuracy (RMS error) was 0.6-1.0 mm and 0.6-2.2° for the CT-based registration and 1.4-2.2 mm and 1.2-2.6° for MRI-based registration. Higher kinematic accuracy of CT-based registration was expected as MRI provides lower spatial resolution and bone contrast as compared to CT and suffers from spatial distortions. However, the MRI-based registration is within an acceptable accuracy for many clinical research questions.
Collapse
Affiliation(s)
- Mohsen Akbari-Shandiz
- Assistive and Restorative Technology Laboratory, Rehabilitation Medicine Research Center, Department of Physical Medicine & Rehabilitation, Mayo Clinic, Rochester, MN, USA; Department of Rehabilitation Medicine, Divisions of Rehabilitation Science and Physical Therapy, Medical School, University of Minnesota, MN, USA
| | - Rebekah L Lawrence
- Department of Rehabilitation Medicine, Divisions of Rehabilitation Science and Physical Therapy, Medical School, University of Minnesota, MN, USA
| | - Arin M Ellingson
- Department of Rehabilitation Medicine, Divisions of Rehabilitation Science and Physical Therapy, Medical School, University of Minnesota, MN, USA
| | - Casey P Johnson
- Center for Magnetic Resonance Research, University of Minnesota, Minneapolis, MN, USA
| | - Kristin D Zhao
- Assistive and Restorative Technology Laboratory, Rehabilitation Medicine Research Center, Department of Physical Medicine & Rehabilitation, Mayo Clinic, Rochester, MN, USA
| | - Paula M Ludewig
- Department of Rehabilitation Medicine, Divisions of Rehabilitation Science and Physical Therapy, Medical School, University of Minnesota, MN, USA.
| |
Collapse
|
36
|
Cho WJ, Kim JM, Kim DE, Lee JG, Park JW, Han YH, Seo HG. Accuracy of the femoral tunnel position in robot-assisted anterior cruciate ligament reconstruction using a magnetic resonance imaging-based navigation system: A preliminary report. Int J Med Robot 2018; 14:e1933. [PMID: 29952064 DOI: 10.1002/rcs.1933] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2017] [Revised: 05/16/2018] [Accepted: 05/23/2018] [Indexed: 11/06/2022]
Abstract
BACKGROUND Tunnel misplacement is a common cause of failed anterior cruciate ligament (ACL) reconstruction. In this study, the accuracy of the femoral tunnel position was evaluated in robot-assisted ACL reconstruction using a magnetic resonance imaging (MRI)-based navigation system. We hypothesized that a difference of less than 2 mm between the planned femoral tunnel position and the created one was achievable. METHODS Four cadaveric knees underwent robot-assisted ACL reconstruction. A 3-dimensional model using pre-operative MRI images was used for preoperative planning, and a computed tomography (CT) scan was performed postoperatively. The planned and the created femoral tunnels were compared to assess the accuracy of the femoral tunnel position. RESULTS The distance between the intra-articular points of the planned and the created tunnels was 7.78 mm in the first experiment and 1.47 mm in the last one. The difference in tunnel length was 4.62 mm in the first experiment and 0.99 mm in the last one. CONCLUSIONS Accuracy of the femoral tunnel position improved with each robot-assisted ACL reconstruction using an MRI-based navigation system. In the last experiment, the accuracy of the femoral tunnel position was satisfactory.
Collapse
Affiliation(s)
- Won-Joon Cho
- Bonbridge Hospital, Investigation performed at the University of Ulsan College of Medicine, Seoul, South Korea
| | - Jong-Min Kim
- Asan Medical Center, Investigation performed at the University of Ulsan College of Medicine, Seoul, South Korea
| | - Dong-Eun Kim
- Hospital Run, Investigation performed at the University of Ulsan College of Medicine, Seoul, South Korea
| | - June-Goo Lee
- Asan Medical Center, Investigation performed at the University of Ulsan College of Medicine, Seoul, South Korea
| | - Jun-Woo Park
- Curexo Inc., Investigation performed at the University of Ulsan College of Medicine, Seongnam, South Korea
| | - Yong-Hee Han
- Curexo Inc., Investigation performed at the University of Ulsan College of Medicine, Seongnam, South Korea
| | - Hyun-Gi Seo
- Corelinesoft, Co., Ltd, Investigation performed at the University of Ulsan College of Medicine, Seoul, South Korea
| |
Collapse
|
37
|
Evaluation of three-dimensional in vivo scapular kinematics and scapulohumeral rhythm between shoulders with a clavicle hook plate and contralateral healthy shoulders. INTERNATIONAL ORTHOPAEDICS 2018; 43:379-386. [DOI: 10.1007/s00264-018-4003-y] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/07/2017] [Accepted: 05/28/2018] [Indexed: 10/14/2022]
|
38
|
Grasso S, Linklater J, Li Q, Parker DA. Validation of an MRI Protocol for Routine Quantitative Assessment of Tunnel Position in Anterior Cruciate Ligament Reconstruction. Am J Sports Med 2018; 46:1624-1631. [PMID: 29589954 DOI: 10.1177/0363546518758950] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND No standardized methodology and objective criteria currently exist to accurately and objectively assess tunnel placement and consequent graft orientation in anterior cruciate ligament (ACL) reconstruction (ACLR) through a single imaging modality. Advances in magnetic resonance imaging (MRI) technology have enabled the use of volumetric high spatial and contrast resolution proton density-weighted sequencing, which allows precise delineation of graft orientation, tunnel position, and quantitative assessment of tunnel position relationship to adjacent reproducible anatomic landmarks. PURPOSE To establish an MRI protocol that would provide an accurate alternative to 3-dimensional computed tomography (3D-CT) for standardized assessment of bone tunnel placement in ACLR, as a component of assessing ACLR outcomes and to assist in presurgical planning for revision ACLR. STUDY DESIGN Cohort study (diagnosis); Level of evidence, 2. METHODS Twenty-four participants diagnosed with a failed ACLR underwent MRI and 3D-CT per the imaging protocols of the Sydney Orthopaedic Research Institute, in which the acquired data were converted to 3D models. The bone tunnels of the previous ACLR were then intraoperatively digitized at the tunnel aperture and along the length of the tunnel (barrel) and used as the reference standard to evaluate the accuracy of high-resolution MRI and 3D-CT. Differences in geometry between the image-based model and the reference point cloud were calculated through point-to-point comparison. RESULTS At the tunnel apertures, no significant differences were detected between the MRI and 3D-CT models versus the reference models for the femur ( P = .9472) and tibia ( P = .5779). Mean ± SD tunnel barrel deviations between MRI and 3D-CT were 0.48 ± 0.28 mm (femur) and 0.46 ± 0.27 mm (tibia). No significant differences were detected between the MRI and 3D-CT models versus the reference models for the femoral ( P = .5730) and tibial ( P = .3002) tunnel barrels. CONCLUSION This study demonstrated that, in addition to being the optimum modality for assessment of soft tissue injury of the knee, a high-resolution 3D turbo spin echo proton density sequence can provide an accurate assessment of tunnel placement, without the use of ionizing radiation. Therefore, this protocol provides the foundation for an objective standardized platform to quantitatively evaluate the location of ACL bone tunnels and graft orientation for routine postoperative assessment, presurgical planning, and evaluation of clinical outcomes.
Collapse
Affiliation(s)
- Samuel Grasso
- Sydney Orthopaedic Research Institute, Chatswood, Australia.,School of Aerospace, Mechanical and Mechatronic Engineering, University of Sydney, Sydney, Australia
| | | | - Qing Li
- School of Aerospace, Mechanical and Mechatronic Engineering, University of Sydney, Sydney, Australia
| | - David A Parker
- Sydney Orthopaedic Research Institute, Chatswood, Australia.,North Shore Knee Clinic, Sydney, Australia
| |
Collapse
|
39
|
Procrustes-based geometric morphometrics on MRI images: An example of inter-operator bias in 3D landmarks and its impact on big datasets. PLoS One 2018; 13:e0197675. [PMID: 29787586 PMCID: PMC5963746 DOI: 10.1371/journal.pone.0197675] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2018] [Accepted: 05/07/2018] [Indexed: 01/25/2023] Open
Abstract
Using 3D anatomical landmarks from adult human head MRIs, we assessed the magnitude of inter-operator differences in Procrustes-based geometric morphometric analyses. An in depth analysis of both absolute and relative error was performed in a subsample of individuals with replicated digitization by three different operators. The effect of inter-operator differences was also explored in a large sample of more than 900 individuals. Although absolute error was not unusual for MRI measurements, including bone landmarks, shape was particularly affected by differences among operators, with up to more than 30% of sample variation accounted for by this type of error. The magnitude of the bias was such that it dominated the main pattern of bone and total (all landmarks included) shape variation, largely surpassing the effect of sex differences between hundreds of men and women. In contrast, however, we found higher reproducibility in soft-tissue nasal landmarks, despite relatively larger errors in estimates of nasal size. Our study exemplifies the assessment of measurement error using geometric morphometrics on landmarks from MRIs and stresses the importance of relating it to total sample variance within the specific methodological framework being used. In summary, precise landmarks may not necessarily imply negligible errors, especially in shape data; indeed, size and shape may be differentially impacted by measurement error and different types of landmarks may have relatively larger or smaller errors. Importantly, and consistently with other recent studies using geometric morphometrics on digital images (which, however, were not specific to MRI data), this study showed that inter-operator biases can be a major source of error in the analysis of large samples, as those that are becoming increasingly common in the 'era of big data'.
Collapse
|
40
|
Kidera K, Yonekura A, Miyaji T, Nakazoe Y, Gamada K, Yoneta K, Ikuta F, Tomita M, Miyamoto T, Kajiyama S, Hozumi A, Chiba K, Okazaki N, Shida T, Osaki M. Double-bundle anterior cruciate ligament reconstruction improves tibial rotational instability: analysis of squatting motion using a 2D/3D registration technique. J Orthop Surg Res 2018; 13:111. [PMID: 29769139 PMCID: PMC5956752 DOI: 10.1186/s13018-018-0825-y] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/06/2017] [Accepted: 05/02/2018] [Indexed: 01/07/2023] Open
Abstract
Background The anterior cruciate ligament-deficient (ACLD) knee requires appropriate treatment for the patient to return to sports. The purpose of this study was to clarify the kinematics of the anterior cruciate ligament-deficient knee in squatting motion before and after double-bundle anterior cruciate ligament reconstruction (DB-ACLR) using a 2D/3D registration technique. Methods The subjects of this study were 10 men with confirmed unilateral ACL rupture who underwent DB-ACLR. Computed tomography (CT) of the knee joints was performed before DB-ACLR. Fluoroscopic imaging of the knee motion in squatting before and after DB-ACLR was also performed. The 2D/3D registration technique is a method of calculating positional relationships by projecting the 3D bone model created from the CT data onto the image extracted from the fluoroscopic images. The tibial anteroposterior (AP) and rotational positions were analyzed with reference to the femur. Results The tibial AP position of the ACLD knees was significantly anterior to the contralateral knees (p = 0.015). The tibial rotational position of the ACLD knees was significantly internally rotated compared to the contralateral knees (p < 0.001). Both tibial AP and rotational positions improved after DB-ACLR (p < 0.001), with no significant differences compared to the contralateral knees. Conclusion DB-ACLR improved not only tibial AP instability but also tibial rotational instability at knee flexion with weight-bearing. DB-ACLR appears to be a useful technique for normalizing the knee joint kinematics of ACLD knees.
Collapse
Affiliation(s)
- Kenichi Kidera
- Department of Orthopaedic Surgery, Nagasaki University Graduate School of Biomedical Sciences, 1-7-1 Sakamoto, Nagasaki, 852-8501, Japan
| | - Akihiko Yonekura
- Department of Orthopaedic Surgery, Nagasaki University Graduate School of Biomedical Sciences, 1-7-1 Sakamoto, Nagasaki, 852-8501, Japan.
| | - Takeshi Miyaji
- Department of Orthopaedic Surgery, Nagasaki University Graduate School of Biomedical Sciences, 1-7-1 Sakamoto, Nagasaki, 852-8501, Japan
| | - Yusuke Nakazoe
- Department of Orthopaedic Surgery, Nagasaki University Graduate School of Biomedical Sciences, 1-7-1 Sakamoto, Nagasaki, 852-8501, Japan
| | - Kazuyoshi Gamada
- Medical Engineering and Technology, Graduate School of Medical Technology and Health Welfare Sciences, Hiroshima International University, Hiroshima, Japan
| | - Kei Yoneta
- Medical Engineering and Technology, Graduate School of Medical Technology and Health Welfare Sciences, Hiroshima International University, Hiroshima, Japan
| | - Futoshi Ikuta
- Medical Engineering and Technology, Graduate School of Medical Technology and Health Welfare Sciences, Hiroshima International University, Hiroshima, Japan
| | - Masato Tomita
- Department of Orthopaedic Surgery, Nagasaki University Graduate School of Biomedical Sciences, 1-7-1 Sakamoto, Nagasaki, 852-8501, Japan
| | - Takashi Miyamoto
- Department of Orthopaedic Surgery, Nagasaki University Graduate School of Biomedical Sciences, 1-7-1 Sakamoto, Nagasaki, 852-8501, Japan
| | - Shiro Kajiyama
- Department of Orthopaedic Surgery, Nagasaki University Graduate School of Biomedical Sciences, 1-7-1 Sakamoto, Nagasaki, 852-8501, Japan
| | - Akira Hozumi
- Department of Orthopaedic Surgery, Nagasaki University Graduate School of Biomedical Sciences, 1-7-1 Sakamoto, Nagasaki, 852-8501, Japan
| | - Ko Chiba
- Department of Orthopaedic Surgery, Nagasaki University Graduate School of Biomedical Sciences, 1-7-1 Sakamoto, Nagasaki, 852-8501, Japan
| | - Narihiro Okazaki
- Department of Orthopaedic Surgery, Nagasaki University Graduate School of Biomedical Sciences, 1-7-1 Sakamoto, Nagasaki, 852-8501, Japan
| | - Takayuki Shida
- Department of Orthopaedic Surgery, Nagasaki University Graduate School of Biomedical Sciences, 1-7-1 Sakamoto, Nagasaki, 852-8501, Japan
| | - Makoto Osaki
- Department of Orthopaedic Surgery, Nagasaki University Graduate School of Biomedical Sciences, 1-7-1 Sakamoto, Nagasaki, 852-8501, Japan
| |
Collapse
|
41
|
Schröder FF, Verdonschot NJJ, Ten Haken B, Peters A, Vochteloo AJH, Pakvis DFM, Huis In't Veld R. Low-field magnetic resonance imaging offers potential for measuring tibial component migration. J Exp Orthop 2018; 5:4. [PMID: 29330713 PMCID: PMC5766455 DOI: 10.1186/s40634-017-0116-2] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/11/2017] [Accepted: 12/20/2017] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Roentgen stereophotogrammetric analysis (RSA) is used to measure early prosthetic migration and to predict future implant failure. RSA has several disadvantages, such as the need for perioperatively inserted tantalum markers. Therefore, this study evaluates low-field MRI as an alternative to RSA. The use of traditional MRI with prostheses induces disturbing metal artifacts which are reduced by low-field MRI. The purpose of this study is to assess the feasibility to use low-field (0.25 Tesla) MRI for measuring the precision of zero motion. This was assessed by calculating the virtual prosthetic motion of a zero-motion prosthetic reconstruction in multiple scanning sessions. Furthermore, the effects of different registration methods on these virtual motions were tested. RESULTS The precision of zero motion for low-field MRI was between 0.584 mm and 1.974 mm for translation and 0.884° and 3.774° for rotation. The manual registration method seemed most accurate, with μ ≤ 0.13 mm (σ ≤ 0.931 mm) for translation and μ ≤ 0.15° (σ ≤ 1.63°) for rotation. CONCLUSION Low-field MRI is not yet as precise as today's golden standard (marker based RSA) as reported in the literature. However, low-field MRI is feasible of measuring the relative position of bone and implant with comparable precision as obtained with marker-free RSA techniques. Of the three registration methods tested, manual registration was most accurate. Before starting clinical validation further research is necessary and should focus on improving scan sequences and registration algorithms.
Collapse
Affiliation(s)
- F F Schröder
- Centre for Orthopaedic Surgery OCON, Hengelo, The Netherlands. .,MIRA Institute for Biomedical Technology and Technical Medicine, University of Twente, Enschede, the Netherlands.
| | - N J J Verdonschot
- MIRA Institute for Biomedical Technology and Technical Medicine, University of Twente, Enschede, the Netherlands.,Radboud Institute for Health Sciences, Orthopaedic Research Lab, Radboud university medical center, Nijmegen, The Netherlands
| | - B Ten Haken
- MIRA Institute for Biomedical Technology and Technical Medicine, University of Twente, Enschede, the Netherlands
| | - A Peters
- Centre for Orthopaedic Surgery OCON, Hengelo, The Netherlands
| | - A J H Vochteloo
- Centre for Orthopaedic Surgery OCON, Hengelo, The Netherlands
| | - D F M Pakvis
- Centre for Orthopaedic Surgery OCON, Hengelo, The Netherlands
| | | |
Collapse
|
42
|
Kozono N, Okada T, Takeuchi N, Hamai S, Higaki H, Shimoto T, Ikebe S, Gondo H, Nakanishi Y, Senju T, Nakashima Y. Dynamic kinematics of the glenohumeral joint in shoulders with rotator cuff tears. J Orthop Surg Res 2018; 13:9. [PMID: 29325577 PMCID: PMC5765635 DOI: 10.1186/s13018-017-0709-6] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/15/2017] [Accepted: 12/26/2017] [Indexed: 11/29/2022] Open
Abstract
Background No clear trend has emerged from the literature regarding three-dimensional (3D) translations of the humerus relative to the scapula in shoulders with rotator cuff tears (RCTs). The purpose of this study was to evaluate the kinematics of RCT shoulders using 3D-to-two-dimensional (2D) model-to-image registration techniques. Methods Dynamic glenohumeral kinematics during scapular plane abduction and axial rotation were analyzed in 11 RCT patients and 10 healthy control subjects. We measured the 3D kinematic parameters of glenohumeral joints using X-ray images and CT-derived digitally reconstructed radiographs. Results For scapular plane abduction, the humeral head center was positioned significantly more medially in shoulders with RCTs than in controls at 135° of humeral abduction (p = 0.02; RCTs versus controls: − 0.9 ± 1.6 versus 0.3 ± 1.3 mm). There was no significant difference in the superior/inferior translation of the humeral head center (p = 0.99). For axial rotation in adducted position, the humeral head center was positioned significantly more anteriorly in shoulders with RCTs than in controls at − 30° of glenohumeral external rotation (p < 0.0001; RCTs versus controls: 3.0 ± 1.7 versus 0.3 ± 1.5 mm). Conclusions This study revealed the kinematics of shoulders with large to massive full-thickness RCTs: the humeral head center showed a medial shift at the late phase of scapular plane full abduction, and an anterior shift at the internal rotation position during full axial rotation. The kinematic data in this study, which describe the patterns of movement of shoulders with large to massive full-thickness RCTs, provide valuable information for future studies investigating glenohumeral translations in other pathological conditions of the shoulder. For clinical relevance, quantitative assessment of the dynamic kinematics of shoulders with RCTs might be a therapeutic indicator for achieving functional restoration.
Collapse
Affiliation(s)
- Naoya Kozono
- Department of Orthopaedic Surgery, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka City, Fukuoka, 812-8582, Japan
| | - Takamitsu Okada
- Department of Orthopaedic Surgery, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka City, Fukuoka, 812-8582, Japan.
| | - Naohide Takeuchi
- Department of Orthopaedic Surgery, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka City, Fukuoka, 812-8582, Japan
| | - Satoshi Hamai
- Department of Orthopaedic Surgery, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka City, Fukuoka, 812-8582, Japan
| | - Hidehiko Higaki
- Department of Life Science, Faculty of Life Science, Kyushu Sangyo University, 2-3-1, Matsukadai, Higashi-ku, Fukuoka City, Fukuoka, 813-8503, Japan
| | - Takeshi Shimoto
- Department of Information and System Engineering, Faculty of Information Engineering, Fukuoka Institute of Technology, 3-30-1 Wajiro-higashi, Higashi-ku, Fukuoka City, Fukuoka, 811-0295, Japan
| | - Satoru Ikebe
- Department of Creative Engineering, National Institute of Technology, Kitakyushu College, 5-20-1 Shii, Kokuraminami-ku, Kitakyushu City, Fukuoka, 802-0985, Japan
| | - Hirotaka Gondo
- Department of Life Science, Faculty of Life Science, Kyushu Sangyo University, 2-3-1, Matsukadai, Higashi-ku, Fukuoka City, Fukuoka, 813-8503, Japan
| | - Yoshitaka Nakanishi
- Department of Orthopaedic Surgery, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka City, Fukuoka, 812-8582, Japan
| | - Takahiro Senju
- Department of Orthopaedic Surgery, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka City, Fukuoka, 812-8582, Japan
| | - Yasuharu Nakashima
- Department of Orthopaedic Surgery, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka City, Fukuoka, 812-8582, Japan
| |
Collapse
|
43
|
Twiggs JG, Dickison DM, Kolos EC, Wilcox CE, Roe JP, Fritsch BA, McMahon SJ, Miles BP, Ruys AJ. Patient Variation Limits Use of Fixed References for Femoral Rotation Component Alignment in Total Knee Arthroplasty. J Arthroplasty 2018; 33:67-74. [PMID: 28927560 DOI: 10.1016/j.arth.2017.08.023] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/02/2017] [Revised: 07/24/2017] [Accepted: 08/16/2017] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Optimal rotational alignment of the femoral component is a common goal during total knee arthroplasty. The posterior condylar axis (PCA) is thought to be the most reproducible reference in surgery, while the transepicondylar axis (TEA) seems to better approximate the native kinematic flexion axis. This study sought to determine if rules based on patient gender or coronal alignment could allow reliable reproduction of the TEA from the PCA. METHODS Three-dimensional models based on preoperative computed tomography were made representing a patient's arthritic knee joint. The landmarks were defined and angular relationships determined. RESULTS The population group of 726 patients contained large anatomic variation. When applying the standard reference rule of 3° external rotation from the PCA, 36.9% of patients would have a rotational target greater than ±2° from their TEA. When applying the mean external rotation of the TEA from the PCA (1.85°) from this population, this proportion dropped to 26.0% of patients. The use of statistically significant gender and coronal alignment relationships to define the femoral rotation did not reduce the proportion of patients in ±2° error. CONCLUSION This study shows that gender and coronal alignment relationships to the TEA to PCA angle are not clinically significant as a quarter of patients would still have a target for rotation greater than ±2° from the TEA using these relationships. Superior tools for orienting rotational cuts directly to the TEA in surgery or preoperative identification of relevant patient-specific angles might capture the proportion of patients for whom standard reference angles are not appropriate.
Collapse
Affiliation(s)
- Joshua G Twiggs
- Department of Biomedical Engineering, AMME, University of Sydney, Sydney, New South Wales, Australia; 360 Knee Systems Pty Ltd, Pymble, New South Wales, Australia
| | | | | | | | - Justin P Roe
- North Sydney Orthopaedic and Sports Medicine Centre, Wollstonecraft, New South Wales, Australia
| | - Brett A Fritsch
- Sydney Orthopaedic Research Institute, Chatswood, New South Wales, Australia
| | | | - Brad P Miles
- 360 Knee Systems Pty Ltd, Pymble, New South Wales, Australia
| | - Andrew J Ruys
- Department of Biomedical Engineering, AMME, University of Sydney, Sydney, New South Wales, Australia
| |
Collapse
|
44
|
Roach KE, Wang B, Kapron AL, Fiorentino NM, Saltzman CL, Bo Foreman K, Anderson AE. In Vivo Kinematics of the Tibiotalar and Subtalar Joints in Asymptomatic Subjects: A High-Speed Dual Fluoroscopy Study. J Biomech Eng 2017; 138:2539410. [PMID: 27455417 DOI: 10.1115/1.4034263] [Citation(s) in RCA: 38] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2016] [Indexed: 11/08/2022]
Abstract
Measurements of joint kinematics are essential to understand the pathomechanics of ankle disease and the effects of treatment. Traditional motion capture techniques do not provide measurements of independent tibiotalar and subtalar joint motion. In this study, high-speed dual fluoroscopy images of ten asymptomatic adults were acquired during treadmill walking at 0.5 m/s and 1.0 m/s and a single-leg, balanced heel-rise. Three-dimensional (3D) CT models of each bone and dual fluoroscopy images were used to quantify in vivo kinematics for the tibiotalar and subtalar joints. Dynamic tibiotalar and subtalar mean joint angles often exhibited opposing trends during captured stance. During both speeds of walking, the tibiotalar joint had significantly greater dorsi/plantarflexion (D/P) angular ROM than the subtalar joint while the subtalar joint demonstrated greater inversion/eversion (In/Ev) and internal/external rotation (IR/ER) than the tibiotalar joint. During balanced heel-rise, only D/P and In/Ev were significantly different between the tibiotalar and subtalar joints. Translational ROM in the anterior/posterior (AP) direction was significantly greater in the subtalar than the tibiotalar joint during walking at 0.5 m/s. Overall, our results support the long-held belief that the tibiotalar joint is primarily responsible for D/P, while the subtalar joint facilitates In/Ev and IR/ER. However, the subtalar joint provided considerable D/P rotation, and the tibiotalar joint rotated about all three axes, which, along with translational motion, suggests that each joint undergoes complex, 3D motion.
Collapse
|
45
|
Zheng L, Carey R, Thorhauer E, Tashman S, Harner C, Zhang X. In vivo tibiofemoral skeletal kinematics and cartilage contact arthrokinematics during decline walking after isolated meniscectomy. Med Eng Phys 2017; 51:41-48. [PMID: 29122451 DOI: 10.1016/j.medengphy.2017.10.014] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2016] [Revised: 10/16/2017] [Accepted: 10/29/2017] [Indexed: 10/18/2022]
Abstract
We investigated the effects of isolated meniscectomy on tibiofemoral skeletal kinematics and cartilage contact arthrokinematics in vivo. We recruited nine patients who had undergone isolated medial or lateral meniscectomy, and used a dynamic stereo-radiography (DSX) system to image the patients' knee motion during decline walking. A volumetric model-based tracking process determined 3D tibiofemoral kinematics from the recorded DSX images. Cartilage contact arthrokinematics was derived from the intersection between tibial and femoral cartilage models co-registered to the bones. The kinematics and arthrokinematics were analyzed for early stance and loading response phase (30% of a gait cycle), comparing the affected and intact knees. Results showed that four patients with medial meniscectomy had significantly greater contact centroid excursions in the meniscectomized medial compartments while five patients with lateral meniscectomy had significantly greater cartilage contact area and lateral shift of contact centroid path in the meniscectomized lateral compartments, comparing to those of the same compartments in the contralateral intact knees. No consistent difference however was identified in the skeletal kinematics. The current study demonstrated that cartilage-based intra-articular arthrokinematics is more sensitive and insightful than the skeletal kinematics in assessing the meniscectomy effects.
Collapse
Affiliation(s)
- Liying Zheng
- Department of Mechanical Engineering and Materials Science, University of Pittsburgh, Pittsburgh, PA, USA; Health Effects Lab Division, National Institute for Occupational Safety and Health, Morgantown, WV, USA
| | - Robert Carey
- Department of Mechanical Engineering and Materials Science, University of Pittsburgh, Pittsburgh, PA, USA
| | - Eric Thorhauer
- Department of Mechanical Engineering, University of Washington, Seattle, WA, USA
| | - Scott Tashman
- Department of Orthopaedic Surgery, University of Texas, Houston, TX, USA
| | - Christopher Harner
- Department of Orthopaedic Surgery, University of Texas, Houston, TX, USA
| | - Xudong Zhang
- Department of Mechanical Engineering and Materials Science, University of Pittsburgh, Pittsburgh, PA, USA; Department of Industrial & Systems Engineering, Texas A&M University, College Station, TX, USA; Department of Mechanical Engineering, Texas A&M University, College Station, TX, USA.
| |
Collapse
|
46
|
In vivo kinematics of early-stage osteoarthritic knees during pivot and squat activities. Gait Posture 2017; 58:214-219. [PMID: 28806709 DOI: 10.1016/j.gaitpost.2017.07.116] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/28/2016] [Revised: 07/25/2017] [Accepted: 07/28/2017] [Indexed: 02/02/2023]
Abstract
Kinematic changes have been shown to accompany severe knee osteoarthritis, but no studies have analyzed early-stage osteoarthritic knee kinematics in the transverse plane during functional activities. The purpose of this study was to analyze kinematics of early-stage osteoarthritic knees using model registration techniques. Fifteen early-stage osteoarthritic knees from eight females with a mean age of 52 years old (range, 43-57years old) were involved in this study. A radiologist confirmed with plain radiographs that knees had Kellgren-Lawrence grade-1 or -2 arthritic changes. Fluoroscopic images of squat and pivot activities were recorded for each subject. Three-dimensional surface models of the distal femur and proximal tibia were created from CT images, and anatomic coordinate systems were embedded in each model. The three-dimensional position and orientation of the femur and the tibia were determined using model-image registration techniques, and tibial anteroposterior translation and internal/external rotation relative to the femur were calculated. The contact points of the medial and lateral femoral condyle were also computed. Compared to healthy knees, osteoarthritic knees showed lateral contact points that were significantly shifted anteriorly in both pivot (P<0.001) and squat (P=0.001) activities and greater tibial external rotation in pivot activity (P=0.007). The medial contact point location was similar to healthy knees, but the amount of anteroposterior translation was smaller (P<0.001). These kinematic changes might change stress distributions in the medial compartment during weight-bearing activities. The changes in kinematics possibly have some influence on initiation or progression of knee osteoarthritis.
Collapse
|
47
|
Kim D, Lee D, Jang Y, Yeom J, Banks SA. Effects of short malunion of the clavicle on in vivo scapular kinematics. J Shoulder Elbow Surg 2017; 26:e286-e292. [PMID: 28478902 DOI: 10.1016/j.jse.2017.03.013] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/16/2016] [Revised: 03/07/2017] [Accepted: 03/07/2017] [Indexed: 02/01/2023]
Abstract
BACKGROUND Short malunion of the clavicle after fracture can change scapular kinematics and alter clinical outcome. However, the effects of malunion on kinematics and outcomes remains poorly understood because there have been no in vivo studies measuring changes during active motion with malunion. This study aimed to measure and to compare in vivo 3-dimensional (3D) scapular kinematics between normal shoulders and shoulders with short malunion using 3D-2-dimensional model image registration techniques. METHODS Fifteen patients with clavicle fracture who had been treated conservatively were enrolled in this study. In these patients, the angle of scapular upward rotation, posterior tilting, and external rotation were compared between shoulders with short malunion and contralateral, normal shoulders. A 3D-2-dimensional model image registration technique was used to determine the 3D orientation of the scapula. RESULTS Scapular upward rotation increased following increase of the arm elevation angle and also showed a significant difference by arm elevation in both groups (P = .04). Posterior tilting of the scapula gradually increased as the arm abduction angle increased, and this varied significantly between groups (P = .01). Shoulders with short malunion also showed a more internally rotated position than the contralateral, normal shoulders between 100° and the maximum abduction angle (P = .04). CONCLUSION Our results suggest that clavicle shortening of >10% greatly affects scapular kinematics in vivo. Further studies will be needed to determine the clinical implications of short malunion of the clavicle.
Collapse
Affiliation(s)
- DooSup Kim
- Department of Orthopedic Surgery, Wonju College of Medicine, Yonsei University, Wonju Severance Christian Hospital, Gangwon, Republic of Korea; Department of Mechanical and Aerospace Engineering, University of Florida, Gainesville, FL, USA
| | - DongWoo Lee
- Department of Orthopedic Surgery, Wonju College of Medicine, Yonsei University, Wonju Severance Christian Hospital, Gangwon, Republic of Korea
| | - YoungHwan Jang
- Department of Orthopedic Surgery, Wonju College of Medicine, Yonsei University, Wonju Severance Christian Hospital, Gangwon, Republic of Korea
| | - JunSeop Yeom
- Department of Orthopedic Surgery, Wonju College of Medicine, Yonsei University, Wonju Severance Christian Hospital, Gangwon, Republic of Korea
| | - Scott A Banks
- Department of Mechanical and Aerospace Engineering, University of Florida, Gainesville, FL, USA.
| |
Collapse
|
48
|
Comparison of 3D bone models of the knee joint derived from CT and 3T MR imaging. Eur J Radiol 2017; 93:178-184. [DOI: 10.1016/j.ejrad.2017.05.042] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2016] [Revised: 09/18/2016] [Accepted: 05/30/2017] [Indexed: 11/18/2022]
|
49
|
Kozono N, Okada T, Takeuchi N, Hamai S, Higaki H, Ikebe S, Shimoto T, Miake G, Nakanishi Y, Iwamoto Y. In vivo kinematic analysis of the glenohumeral joint during dynamic full axial rotation and scapular plane full abduction in healthy shoulders. Knee Surg Sports Traumatol Arthrosc 2017; 25:2032-2040. [PMID: 27511218 DOI: 10.1007/s00167-016-4263-2] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/13/2016] [Accepted: 08/02/2016] [Indexed: 11/28/2022]
Abstract
PURPOSE The purpose of this study was to evaluate the kinematics of healthy shoulders during dynamic full axial rotation and scapular plane full abduction using three-dimensional (3D)-to-two-dimensional (2D) model-to-image registration techniques. METHODS Dynamic glenohumeral kinematics during axial rotation and scapular plane abduction were analysed in 10 healthy participants. Continuous radiographic images of axial rotation and scapular plane abduction were taken using a flat panel radiographic detector. The participants received a computed tomography scan to generate virtual digitally reconstructed radiographs. The density-based digitally reconstructed radiographs were then compared with the serial radiographic images acquired using image correlations. These 3D-to-2D model-to-image registration techniques determined the 3D positions and orientations of the humerus and scapula during dynamic full axial rotation and scapular plane full abduction. RESULTS The humeral head centre translated an average of 2.5 ± 3.1 mm posteriorly, and 1.4 ± 1.0 mm superiorly in the early phase, then an average of 2.0 ± 0.8 mm inferiorly in the late phase during external rotation motion. The glenohumeral external rotation angle had a significant effect on the anterior/posterior (A/P) and superior/inferior (S/I) translation of the humeral head centre (both p < 0.05). 33.6 ± 15.6° of glenohumeral external rotation occurred during scapular plane abduction. The humeral head centre translated an average of 0.6 ± 0.9 mm superiorly in the early phase, then 1.7 ± 2.6 mm inferiorly in the late phase, and translated an average of 0.4 ± 0.5 mm medially in the early phase, then 1.6 ± 1.0 mm laterally in the late phase during scapular plane abduction. The humeral abduction angle had a significant effect on the S/I and lateral/medial (L/M) translation of the humeral head centre (both p < 0.05). CONCLUSION This study investigated 3D translations of the humerus relative to the scapula: during scapular plane full abduction, the humerus rotated 33.6° externally relative to the scapula, and during external rotation motion in the adducted position, the humeral head centre translated an average of 2.5 mm posteriorly. Kinematic data will provide important insights into evaluating the kinematics of pathological shoulders. For clinical relevance, quantitative assessment of dynamic healthy shoulder kinematics might be a physiological indicator for the assessment of pathological shoulders.
Collapse
Affiliation(s)
- Naoya Kozono
- Department of Orthopaedic Surgery, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka City, Fukuoka, 812-8582, Japan
| | - Takamitsu Okada
- Department of Orthopaedic Surgery, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka City, Fukuoka, 812-8582, Japan.
| | - Naohide Takeuchi
- Department of Orthopaedic Surgery, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka City, Fukuoka, 812-8582, Japan
| | - Satoshi Hamai
- Department of Orthopaedic Surgery, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka City, Fukuoka, 812-8582, Japan
| | - Hidehiko Higaki
- Department of Biorobotics, Faculty of Engineering, Kyushu Sangyo University, 2-3-1, Matsukadai, Higashi-ku, Fukuoka City, Fukuoka, 813-8503, Japan
| | - Satoru Ikebe
- Department of Biorobotics, Faculty of Engineering, Kyushu Sangyo University, 2-3-1, Matsukadai, Higashi-ku, Fukuoka City, Fukuoka, 813-8503, Japan
| | - Takeshi Shimoto
- Department of Information and System Engineering, Faculty of Information Engineering, Fukuoka Institute of Technology, 3-30-1 Wajiro-higashi, Higashi-ku, Fukuoka City, Fukuoka, 811-0295, Japan
| | - Go Miake
- Department of Orthopaedic Surgery, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka City, Fukuoka, 812-8582, Japan
| | - Yoshitaka Nakanishi
- Department of Orthopaedic Surgery, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka City, Fukuoka, 812-8582, Japan
| | - Yukihide Iwamoto
- Department of Orthopaedic Surgery, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka City, Fukuoka, 812-8582, Japan
| |
Collapse
|
50
|
Nicholson KF, Richardson RT, Miller F, Richards JG. Determining 3D scapular orientation with scapula models and biplane 2D images. Med Eng Phys 2017; 41:103-108. [PMID: 28126419 DOI: 10.1016/j.medengphy.2017.01.012] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2015] [Revised: 08/18/2016] [Accepted: 01/08/2017] [Indexed: 10/20/2022]
Abstract
This study evaluated a strategy for identifying 3D scapulothoracic orientation using bilateral X-ray scans and 3D scapula models. Both subject-specific scapula models and a scaled general model were utilized. 3D scapulothoracic orientations obtained from X-rays were compared to motion capture data. "Subjects" consisted of a skeletal model of a human torso and ten real bone scapulae. Retroreflective markers were placed on the scapulae and a three-marker triad was placed on the trunk. Marker positions were recorded using an eight camera motion capture system. A biplane X-ray system from EOS Imaging was used to collect two orthogonal 2D images of the skeleton and markers. Custom software was created for the 3D to 2D matching process. The results indicated that the matched orientations compared favorably to motion capture orientations, with RMSE errors ranging from 3.1° to 5.5° and a mean error of 3.9° The proposed strategy was shown to be accurate for both subject-specific models and a scaled general model.
Collapse
Affiliation(s)
- Kristen F Nicholson
- Biomechanics and Movement Science Program, University of Delaware, Newark, DE, USA.
| | - R Tyler Richardson
- Biomechanics and Movement Science Program, University of Delaware, Newark, DE, USA.
| | - Freeman Miller
- Nemours Alfred I. duPont Hospital for Children, Wilmington, Delaware, USA.
| | - James G Richards
- Biomechanics and Movement Science Program, University of Delaware, Newark, DE, USA.
| |
Collapse
|