Bugeja JM, Chandra SS, Neubert A, Fripp J, Lockard CA, Ho CP, Crozier S, Engstrom C. Automated analysis of immediate reliability of T2 and T2* relaxation times of hip joint cartilage from 3 T MR examinations.
Magn Reson Imaging 2021;
82:42-54. [PMID:
34147595 DOI:
10.1016/j.mri.2021.06.008]
[Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2020] [Revised: 03/31/2021] [Accepted: 06/15/2021] [Indexed: 10/21/2022]
Abstract
BACKGROUND
Magnetic resonance (MR) T2 and T2* mapping sequences allow in vivo quantification of biochemical characteristics within joint cartilage of relevance to clinical assessment of conditions such as hip osteoarthritis (OA).
PURPOSE
To evaluate an automated immediate reliability analysis of T2 and T2* mapping from MR examinations of hip joint cartilage using a bone and cartilage segmentation pipeline based around focused shape modelling.
STUDY TYPE
Technical validation.
SUBJECTS
17 asymptomatic volunteers (M: F 7:10, aged 22-47 years, mass 50-90 kg, height 163-189 cm) underwent unilateral hip joint MR examinations. Automated analysis of cartilage T2 and T2* data immediate reliability was evaluated in 9 subjects (M: F 4: 5) for each sequence.
FIELD STRENGTH/SEQUENCE
A 3 T MR system with a body matrix flex-coil was used to acquire images with the following sequences: T2 weighted 3D-trueFast Imaging with Steady-State Precession (water excitation; 10.18 ms repetition time (TR); 4.3 ms echo time (TE); Voxel Size (VS): 0.625 × 0.625 × 0.65 mm; 160 mm field of view (FOV); Flip Angle (FA): 30 degrees; Pixel Bandwidth (PB): 140 Hz/pixel); a multi-echo spin echo (MESE) T2 mapping sequence (TR/TE: 2080/18-90 ms (5 echoes); VS: 4 × 0.78 × 0.78 mm; FOV: 200 mm; FA: 180 degrees; PB: 230 Hz/pixel) and a MESE T2* mapping sequence (TR/TE: 873/3.82-19.1 ms (5 echoes); VS: 3 × 0.625 × 0.625 mm; FOV: 160 mm; FA: 25 degrees; PB: 250 Hz/pixel).
ASSESSMENT
Automated cartilage segmentation and quantitative analysis provided T2 and T2* data from test-retest MR examinations to assess immediate reliability.
STATISTICAL TESTS
Coefficient of variation (CV) and intraclass correlations (ICC2, 1) to analyse automated T2 and T2* mapping reliability focusing on the clinically important superior cartilage regions of the hip joint.
RESULTS
Comparisons between test-retest T2 and (T2*) data revealed mean CV's of 3.385% (1.25%), mean ICC2, 1's of 0.871 (0.984) and median mean differences of -1.139ms (+0.195ms).
CONCLUSION
The T2 and T2* times from automated analyses of hip cartilage from test-retest MR examinations had high (T2) and excellent (T2*) immediate reliability.
Collapse