1
|
Harrington MS, Di Leo SD, Hlady CA, Burkhart TA. Musculoskeletal modeling and movement simulation for structural hip disorder research: A scoping review of methods, validation, and applications. Heliyon 2024; 10:e35007. [PMID: 39157349 PMCID: PMC11328100 DOI: 10.1016/j.heliyon.2024.e35007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2024] [Accepted: 07/22/2024] [Indexed: 08/20/2024] Open
Abstract
Musculoskeletal modeling is a powerful tool to quantify biomechanical factors typically not feasible to measure in vivo, such as hip contact forces and deep muscle activations. While technological advancements in musculoskeletal modeling have increased accessibility, selecting the appropriate modeling approach for a specific research question, particularly when investigating pathological populations, has become more challenging. The purposes of this review were to summarize current modeling and simulation methods in structural hip disorder research, as well as evaluate model validation and study reproducibility. MEDLINE and Web of Science were searched to identify literature relating to the use of musculoskeletal models to investigate structural hip disorders (i.e., involving a bony abnormality of the pelvis, femur, or both). Forty-seven articles were included for analysis, which either compared multiple modeling methods or applied a single modeling workflow to answer a research question. Findings from studies comparing methods were summarized, such as the effect of generic versus patient-specific modeling techniques on model-estimated hip contact forces or muscle forces. The review also discussed limitations in validation practices, as only 11 of the included studies conducted a validation and used qualitative approaches only. Given the lack of information related to model validation, additional details regarding the development and validation of generic models were retrieved from references and modeling software documentation. To address the wide variability and under-reporting of data collection, data processing, and modeling methods highlighted in this review, we developed a template that researchers can complete and include as a table within the methodology section of their manuscripts. The use of this table will help increase transparency and reporting of essential details related to reproducibility and methods without being limited by word count restrictions. Overall, this review provides a comprehensive synthesis of modeling approaches that can help researchers make modeling decisions and evaluate existing literature.
Collapse
Affiliation(s)
- Margaret S. Harrington
- Faculty of Kinesiology and Physical Education, University of Toronto, Toronto, ON, Canada
| | - Stefania D.F. Di Leo
- Faculty of Kinesiology and Physical Education, University of Toronto, Toronto, ON, Canada
| | - Courtney A. Hlady
- Faculty of Kinesiology and Physical Education, University of Toronto, Toronto, ON, Canada
- Department of Physical Therapy, University of Toronto, Toronto, ON, Canada
| | - Timothy A. Burkhart
- Faculty of Kinesiology and Physical Education, University of Toronto, Toronto, ON, Canada
| |
Collapse
|
2
|
Rivera RJ, Karasavvidis T, Pagan C, Haffner R, Ast MP, Vigdorchik JM, Debbi EM. Functional assessment in patients undergoing total hip arthroplasty. Bone Joint J 2024; 106-B:764-774. [PMID: 39084648 DOI: 10.1302/0301-620x.106b8.bjj-2024-0142.r1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 08/02/2024]
Abstract
Aims Conventional patient-reported surveys, used for patients undergoing total hip arthroplasty (THA), are limited by subjectivity and recall bias. Objective functional evaluation, such as gait analysis, to delineate a patient's functional capacity and customize surgical interventions, may address these shortcomings. This systematic review endeavours to investigate the application of objective functional assessments in appraising individuals undergoing THA. Methods The Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines were applied. Eligible studies of THA patients that conducted at least one type of objective functional assessment both pre- and postoperatively were identified through Embase, Medline/PubMed, and Cochrane Central database-searching from inception to 15 September 2023. The assessments included were subgrouped for analysis: gait analysis, motion analysis, wearables, and strength tests. Results A total of 130 studies using 15 distinct objective functional assessment methods (FAMs) were identified. The most frequently used method was instrumented gait/motion analysis, followed by the Timed-Up-and-Go test (TUG), 6 minute walk test, timed stair climbing test, and various strength tests. These assessments were characterized by their diagnostic precision and applicability to daily activities. Wearables were frequently used, offering cost-effectiveness and remote monitoring benefits. However, their accuracy and potential discomfort for patients must be considered. Conclusion The integration of objective functional assessments in THA presents promise as a progress-tracking modality for improving patient outcomes. Gait analysis and the TUG, along with advancing wearable sensor technology, have the potential to enhance patient care, surgical planning, and rehabilitation.
Collapse
Affiliation(s)
- Richard J Rivera
- Adult Reconstruction and Joint Replacement, Department of Orthopaedic Surgery, Hospital for Special Surgery, New York, New York, USA
- University of South Florida Morsani College of Medicine, Tampa, Florida, USA
| | - Theofilos Karasavvidis
- Adult Reconstruction and Joint Replacement, Department of Orthopaedic Surgery, Hospital for Special Surgery, New York, New York, USA
| | - Cale Pagan
- Adult Reconstruction and Joint Replacement, Department of Orthopaedic Surgery, Hospital for Special Surgery, New York, New York, USA
| | - Rowan Haffner
- Adult Reconstruction and Joint Replacement, Department of Orthopaedic Surgery, Hospital for Special Surgery, New York, New York, USA
| | - Michael P Ast
- Adult Reconstruction and Joint Replacement, Department of Orthopaedic Surgery, Hospital for Special Surgery, New York, New York, USA
| | - Jonathan M Vigdorchik
- Adult Reconstruction and Joint Replacement, Department of Orthopaedic Surgery, Hospital for Special Surgery, New York, New York, USA
| | - Eytan M Debbi
- Adult Reconstruction and Joint Replacement, Department of Orthopaedic Surgery, Hospital for Special Surgery, New York, New York, USA
| |
Collapse
|
3
|
Sivakumar A, Bennett KJ, Pizzolato C, Rickman M, Thewlis D. Hip biomechanics in early recovery following fixation of intertrochanteric fractures: Results from a randomised controlled trial. J Biomech 2024; 170:112169. [PMID: 38795542 DOI: 10.1016/j.jbiomech.2024.112169] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2023] [Revised: 03/25/2024] [Accepted: 05/21/2024] [Indexed: 05/28/2024]
Abstract
Single and dual integrated screw femoral nails are both commonly used to treat intertrochanteric fractures. This study investigated if using single or dual integrated screw femoral nails result in different post-operative hip joint loading. In the presence of differences, we investigated potential contributing factors. Patients were randomised for treatment via single screw (Stryker, Gamma3) or dual-integrated screw nail (Smith and Nephew, Intertan). Pre-injury mobility levels were collected at enrolment. Hip radiographs and gait data were collected at six weeks (Gamma: 16; Intertan: 15) and six months (Gamma: 14; Intertan: 13) follow-up. The resultant hip joint reaction forces and abductor muscle forces were estimated using electromyography-assisted neuromusculoskeletal modelling during level walking gait. Our primary analysis focused on the resultant hip joint reaction force and abductor muscle forces. We compared between groups, across stance phase of walking gait, using statistical parametric mapping. At six weeks, the Intertan group showed a short (∼5% of stance phase) but substantial (33 % [0.3 × body weight] greater magnitude) resultant hip joint reaction force when compared to the Gamma group (P = 0.022). Higher gluteus medius forces (P = 0.009) were demonstrated in the Intertan group at six weeks. Harris Hip Scores followed the trend seen for the biomechanical outcomes with superior scores for the Intertan group at six weeks postoperative (P = 0.044). The use of dual-integrated screw femoral nails over single screw devices may allow for hip biomechanics more closely resembling normal hip function at earlier post-operative timepoints, but these appear to resolve by six months postoperative.
Collapse
Affiliation(s)
- Arjun Sivakumar
- Centre for Orthopaedic & Trauma Research, The University of Adelaide, South Australia, Australia.
| | - Kieran J Bennett
- The Medical Device Research Institute, Flinders University, South Australia, Australia.
| | - Claudio Pizzolato
- Griffith Centre of Biomedical and Rehabilitation Engineering, Griffith University, Queensland, Australia.
| | - Mark Rickman
- Department of Orthopaedics & Trauma, Royal Adelaide Hospital, South Australia, Australia.
| | - Dominic Thewlis
- Centre for Orthopaedic & Trauma Research, The University of Adelaide, South Australia, Australia.
| |
Collapse
|
4
|
Callary SA, Broekhuis D, Barends J, Ramasamy B, Nelissen RGHH, Solomon LB, Kaptein BL. Virtual biomechanical assessment of porous tantalum and custom triflange components in the treatment of patients with acetabular defects and pelvic discontinuity. Bone Joint J 2024; 106-B:74-81. [PMID: 38688495 DOI: 10.1302/0301-620x.106b5.bjj-2023-0852.r1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 05/02/2024]
Abstract
Aims The aim of this study was to compare the biomechanical models of two frequently used techniques for reconstructing severe acetabular defects with pelvic discontinuity in revision total hip arthroplasty (THA) - the Trabecular Metal Acetabular Revision System (TMARS) and custom triflange acetabular components (CTACs) - using virtual modelling. Methods Pre- and postoperative CT scans from ten patients who underwent revision with the TMARS for a Paprosky IIIB acetabular defect with pelvic discontinuity were retrospectively collated. Computer models of a CTAC implant were designed from the preoperative CT scans of these patients. Computer models of the TMARS reconstruction were segmented from postoperative CT scans using a semi-automated method. The amount of bone removed, the implant-bone apposition that was achieved, and the restoration of the centre of rotation of the hip were compared between all the actual TMARS and the virtual CTAC implants. Results The median amount of bone removed for TMARS reconstructions was significantly greater than for CTAC implants (9.07 cm3 (interquartile range (IQR) 5.86 to 21.42) vs 1.16 cm3 (IQR 0.42 to 3.53) (p = 0.004). There was no significant difference between the median overall implant-bone apposition between TMARS reconstructions and CTAC implants (54.8 cm2 (IQR 28.2 to 82.3) vs 56.6 cm2 (IQR 40.6 to 69.7) (p = 0.683). However, there was significantly more implant-bone apposition within the residual acetabulum (45.2 cm2 (IQR 28.2 to 72.4) vs 25.5 cm2 (IQR 12.8 to 44.1) (p = 0.001) and conversely significantly less apposition with the outer cortex of the pelvis for TMARS implants compared with CTAC reconstructions (0 cm2 (IQR 0 to 13.1) vs 23.2 cm2 (IQR 16.4 to 30.6) (p = 0.009). The mean centre of rotation of the hip of TMARS reconstructions differed by a mean of 11.1 mm (3 to 28) compared with CTAC implants. Conclusion In using TMARS, more bone is removed, thus achieving more implant-bone apposition within the residual acetabular bone. In CTAC implants, the amount of bone removed is minimal, while the implant-bone apposition is more evenly distributed between the residual acetabulum and the outer cortex of the pelvis. The differences suggest that these implants used to treat pelvic discontinuity might achieve short- and long-term stability through different biomechanical mechanisms.
Collapse
Affiliation(s)
- Stuart A Callary
- Centre for Orthopaedic and Trauma Research, The University of Adelaide, Adelaide, Australia
- Department of Orthopaedics and Trauma, Royal Adelaide Hospital, Adelaide, Australia
| | - Demien Broekhuis
- Department of Orthopaedic Surgery, Leiden University Medical Center, Leiden, The Netherlands
| | | | - Boopalan Ramasamy
- Centre for Orthopaedic and Trauma Research, The University of Adelaide, Adelaide, Australia
- Department of Orthopaedics and Trauma, Royal Adelaide Hospital, Adelaide, Australia
| | - Rob G H H Nelissen
- Department of Orthopaedic Surgery, Leiden University Medical Center, Leiden, The Netherlands
| | - Lucian B Solomon
- Centre for Orthopaedic and Trauma Research, The University of Adelaide, Adelaide, Australia
- Department of Orthopaedics and Trauma, Royal Adelaide Hospital, Adelaide, Australia
| | - Bart L Kaptein
- Department of Orthopaedic Surgery, Leiden University Medical Center, Leiden, The Netherlands
| |
Collapse
|
5
|
Fallahnezhad K, Callary SA, O'Rourke D, Bahl JS, Thewlis D, Solomon LB, Taylor M. Corroboration of coupled musculoskeletal model and finite element predictions with in vivo RSA migration of an uncemented acetabular component. J Orthop Res 2024; 42:373-384. [PMID: 37526382 DOI: 10.1002/jor.25671] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/20/2022] [Revised: 06/18/2023] [Accepted: 07/26/2023] [Indexed: 08/02/2023]
Abstract
While finite element (FE) models have been used extensively in orthopedic studies, validation of their outcome metrics has been limited to comparison against ex vivo testing. The aim of this study was to validate FE model predictions of the initial cup mechanical environment against patient-matched in vivo measurements of acetabular cup migration using radiostereometric analysis (RSA). Tailored musculoskeletal and FE models were developed using a combination of three-dimensional (3D) motion capture data and clinical computerized tomography (CT) scans for a cohort of eight individuals who underwent primary total hip replacement and were prospectively enrolled in an RSA study. FE models were developed to calculate the mean modulus of cancellous bone, composite peak micromotion (CPM), composite peak strain (CPS) and percentage area of bone ingrowth. The RSA cup migration at 3 months was used to corroborate the FE output metrics. Qualitatively, all FE-predicted metrics followed a similar rank order as the in vivo RSA 3D migration data. The two cases with the lowest predicted CPM (<20 µm), lowest CPS (<0.0041), and high bone modulus (>917 MPa) were confirmed to have the lowest in vivo RSA 3D migration (<0.14 mm). The two cases with the largest predicted CPM (>80 µm), larger CPS (>0.0119) and lowest bone modulus (<472 MPa) were confirmed to have the largest in vivo RSA 3D migration (>0.78 mm). This study enabled the first corroboration between tailored musculoskeletal and FE model predictions with in vivo RSA cup migration. Investigation of additional patient-matched CT, gait, and RSA examinations may allow further development and validation of FE models.
Collapse
Affiliation(s)
- Khosro Fallahnezhad
- Medical Device Research Institute, College of Science and Engineering, Flinders University, Adelaide, South Australia, Australia
| | - Stuart A Callary
- Centre for Orthopaedics and Trauma Research (COTR), The University of Adelaide, Adelaide, South Australia, Australia
- Department of Orthopaedics and Trauma, Royal Adelaide Hospital, Adelaide, South Australia, Australia
| | - Dermot O'Rourke
- School of Mechanical, Medical and Process Engineering, Queensland University of Technology, Brisbane, Queensland, Australia
| | - Jasvir S Bahl
- Centre for Orthopaedics and Trauma Research (COTR), The University of Adelaide, Adelaide, South Australia, Australia
| | - Dominic Thewlis
- Centre for Orthopaedics and Trauma Research (COTR), The University of Adelaide, Adelaide, South Australia, Australia
- Department of Orthopaedics and Trauma, Royal Adelaide Hospital, Adelaide, South Australia, Australia
| | - Lucian B Solomon
- Centre for Orthopaedics and Trauma Research (COTR), The University of Adelaide, Adelaide, South Australia, Australia
- Department of Orthopaedics and Trauma, Royal Adelaide Hospital, Adelaide, South Australia, Australia
| | - Mark Taylor
- Medical Device Research Institute, College of Science and Engineering, Flinders University, Adelaide, South Australia, Australia
| |
Collapse
|
6
|
Fallahnezhad K, O'Rourke D, Bahl JS, Thewlis D, Taylor M. The role of muscle forces and gait cycle discretization when assessing acetabular cup primary stability: A finite element study. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2023; 230:107351. [PMID: 36709556 DOI: 10.1016/j.cmpb.2023.107351] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/27/2022] [Revised: 12/18/2022] [Accepted: 01/10/2023] [Indexed: 06/18/2023]
Abstract
UNLABELLED The aim of this study was to investigate the influence of the muscle force contribution and loading cycle discretization on the predicted micromotion and interfacial bone strains in the implanted acetabulum. To this end, a patient specific finite element model of the hemipelvis was developed, based on the CT-scan and gait analysis results, collected as part of the authors' previous work. Outcomes of this study suggests that the acetabular cup micromotion and interfacial bone strains can be predicted just using the joint contact force. This helps to reduce the complexity of the finite element models by ignoring the contribution of muscle forces and the associated challenges of mapping these forces to the pelvis. However, the gait cycle needs to be adequately discretised to capture the micromotion at the bone-implant interface. BACKGROUND AND OBJECTIVE The Dalstra load case, which includes muscle forces, has been widely adopted in the literature for studying the mechanical environment in the intact and implanted acetabulum. To simplify the modelling approach, some researchers ignore the contribution of muscle forces. The Dalstra load case is also divided into eight separate load steps (five in the stance phase and three in the swing phase), however, it is unclear whether this adequately captures the micromotions, for a cementless acetabular cup, during a simulated activity. The aim of this study was to investigate the influence of the muscle force contribution and loading cycle discretization on the predicted micromotion and interfacial bone strains. METHODS In this work, a patient specific finite element model of the hemipelvis was developed, based on the CT-scan and gait analysis results, collected as part of the authors' previous work. Finite element simulations were performed using the joint contact and muscle forces derived from two sources. The first approach was used the load case proposed by Dalstra et al. The second approach used joint contact and muscle forces predicted by a musculoskeletal model. Additionally, the musculoskeletal load case was discretised into 50 equal load steps and the results compared with the equivalent Dalstra load steps. RESULTS The results showed that the contribution of the muscle forces resulted in minor differences in both the magnitude and distribution of the predicted acetabular micromotion (up to 4.01% in the mean acetabular micromotion) and interfacial bone strains (up to 10.34% in the mean interfacial bone strains). The degree of gait cycle discretisation had a significant influence on the acetabular micromotion with a difference of 20.89% in the mean acetabular micromotion. CONCLUSION Outcomes of this study suggests that the acetabular cup micromotion and interfacial bone strains can be predicted just using the joint contact force. This helps to reduce the complexity of the finite element models by ignoring the contribution of muscle forces and the associated challenges of mapping these forces to the pelvis. However, the gait cycle needs to be adequately discretised to capture the micromotion at the bone-implant interface.
Collapse
Affiliation(s)
- Khosro Fallahnezhad
- Medical Device Research Institute, College of Science and Engineering, Flinders University, 1284 South Road, Clovelly Park, South Australia 5042, Australia.
| | - Dermot O'Rourke
- School of Mechanical, Medical and Process Engineering, Queensland University of Technology, Gardens Point campus, 2 George St, Brisbane, Brisbane, QLD 4000, Australia
| | - Jasvir S Bahl
- Centre for Orthopaedics and Trauma Research (COTR), The University of Adelaide, 4 North Terrace, Adelaide SA 5000, Australia
| | - Dominic Thewlis
- Centre for Orthopaedics and Trauma Research (COTR), The University of Adelaide, 4 North Terrace, Adelaide SA 5000, Australia
| | - Mark Taylor
- Medical Device Research Institute, College of Science and Engineering, Flinders University, 1284 South Road, Clovelly Park, South Australia 5042, Australia
| |
Collapse
|
7
|
Ground reaction forces and external hip joint moments predict in vivo hip contact forces during gait. J Biomech 2022; 135:111037. [DOI: 10.1016/j.jbiomech.2022.111037] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2021] [Revised: 02/21/2022] [Accepted: 03/09/2022] [Indexed: 11/23/2022]
|
8
|
van Drongelen S, Braun S, Stief F, Meurer A. Comparison of Gait Symmetry and Joint Moments in Unilateral and Bilateral Hip Osteoarthritis Patients and Healthy Controls. Front Bioeng Biotechnol 2021; 9:756460. [PMID: 34805115 PMCID: PMC8599579 DOI: 10.3389/fbioe.2021.756460] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2021] [Accepted: 10/21/2021] [Indexed: 11/13/2022] Open
Abstract
Patients with unilateral hip osteoarthritis show a characteristic gait pattern in which they unload the affected leg and overload the unaffected leg. Information on the gait characteristics of patients with bilateral hip osteoarthritis is very limited. The main purposes of this study were to investigate whether the gait pattern of both legs of patients with bilateral hip osteoarthritis deviates from healthy controls and whether bilateral hip osteoarthritis patients show a more symmetrical joint load compared to unilateral hip osteoarthritis patients. In this prospective study, 26 patients with bilateral hip osteoarthritis, 26 patients with unilateral hip osteoarthritis and 26 healthy controls were included. The three groups were matched for gender, age and walking speed. Patients were scheduled for a unilateral total hip arthroplasty on the more affected/more painful side. All participants underwent a three-dimensional gait analysis. Gait kinematics and gait kinetics of patients and controls were compared using Statistical Parametric Mapping. Corrected for speed, the gait kinematics and kinetics of both legs of patients with bilateral hip osteoarthritis differed from healthy controls. Bilateral patients had symmetrical knee joint loading, in contrast to the asymmetrical knee joint loading in unilateral hip osteoarthritis patients. The ipsilateral leg of the bilateral patients could be included in studies in addition to unilateral hip osteoarthritis patients as no differences were found. Although patients with bilateral hip osteoarthritis show more symmetrical frontal plane knee joint moments, a pathological external knee adduction moment in the second half of stance was present in the ipsilateral leg in patients with unilateral and bilateral hip osteoarthritis. The lateral adjustment of the knee adduction moment may initiate or accelerate progression of degenerative changes in the lateral compartment of the knee.
Collapse
Affiliation(s)
- S van Drongelen
- Dr. Rolf M. Schwiete Research Unit for Osteoarthritis, Department of Orthopedics (Friedrichsheim), University Hospital Frankfurt, Goethe University Frankfurt, Frankfurt, Germany
| | - S Braun
- Department of Orthopedics (Friedrichsheim), University Hospital Frankfurt, Goethe University Frankfurt, Frankfurt, Germany
| | - F Stief
- Department of Orthopedics (Friedrichsheim), University Hospital Frankfurt, Goethe University Frankfurt, Frankfurt, Germany
| | - A Meurer
- Department of Orthopedics (Friedrichsheim), University Hospital Frankfurt, Goethe University Frankfurt, Frankfurt, Germany
| |
Collapse
|
9
|
Review of musculoskeletal modelling in a clinical setting: Current use in rehabilitation design, surgical decision making and healthcare interventions. Clin Biomech (Bristol, Avon) 2021; 83:105292. [PMID: 33588135 DOI: 10.1016/j.clinbiomech.2021.105292] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/24/2020] [Revised: 02/01/2021] [Accepted: 02/04/2021] [Indexed: 02/06/2023]
Abstract
BACKGROUND Musculoskeletal modelling is a common means by which to non-invasively analyse movement. Such models have largely been used to observe function in both healthy and patient populations. However, utility in a clinical environment is largely unknown. The aim of this review was to explore existing uses of musculoskeletal models as a clinical intervention, or decision-making, tool. METHODS A literature search was performed using PubMed and Scopus to find articles published since 2010 and relating to musculoskeletal modelling and joint and muscle forces. FINDINGS 4662 abstracts were found, of which 39 relevant articles were reviewed. Journal articles were categorised into 5 distinct groups: non-surgical treatment, orthoses assessment, surgical decision making, surgical intervention assessment and rehabilitation regime assessment. All reviewed articles were authored by collaborations between clinicians and engineers/modellers. Current uses included insight into the development of osteoarthritis, identifying candidates for hamstring lengthening surgery, and the assessment of exercise programmes to reduce joint damage. INTERPRETATION There is little evidence showing the use of musculoskeletal modelling as a tool for patient care, despite the ability to assess long-term joint loading and muscle overuse during functional activities, as well as clinical decision making to avoid unfavourable treatment outcomes. Continued collaboration between model developers should aim to create clinically-friendly models which can be used with minimal input and experience by healthcare professionals to determine surgical necessity and suitability for rehabilitation regimes, and in the assessment of orthotic devices.
Collapse
|