1
|
Wittrock A, Heermant S, Beckmann C, Wimmer MA, Fischer A, Aßmann M, Debus J. Protein-metal interactions due to fretting corrosion at the taper junction of hip implants: An in vitro investigation using Raman spectroscopy. Acta Biomater 2024:S1742-7061(24)00589-0. [PMID: 39393659 DOI: 10.1016/j.actbio.2024.10.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2024] [Revised: 09/04/2024] [Accepted: 10/04/2024] [Indexed: 10/13/2024]
Abstract
Modular hip implants are a clinically successful and widely used treatment for patients with arthritis. Despite ongoing retrieval studies the understanding of the fundamental physico-chemical mechanisms of friction and wear within the head-taper interface is still limited. Here, we Raman-spectroscopically analyze structural features of the biotribological material which is formed within the taper joint between Ti6Al4V and low-carbon cobalt alloy or high-nitrogen steel surfaces in in vitro gross-slip fretting corrosion tests with bovine calf serum. As a function of the fretting duration, we investigate short and long aliphatic chains and their adsorption behavior on the cobalt- and steel-type surfaces. Using the intensity and frequency shifts of the amide I and III Raman bands, we furthermore identify progressive protein folding and unfolding including the secondary structures of α-helix, β-sheet, and random-coil configuration as well as the formation of proteinaceous clusters depending on the hydrophilicity of the metallic surfaces. We additionally find a mixture of chromates and iron oxides with tryptophan and tyrosine at the worn cobalt alloy and high-nitrogen steel surfaces, respectively. Also, for long fretting duration, sp2 hybridized amorphous carbon is formed due to fretting-induced cleavage of proteins. STATEMENT OF SIGNIFICANCE: Despite efforts enhancing the biomedical tribology of hip implants, the impact of the organic environment on friction and wear at the femoral head-stem taper interface is limitedly understood. Using Raman spectroscopy we resolve structural changes within the biotribological material agglomerated at biomedical-grade metal alloys due to metal-organic interactions during in vitro fretting corrosion tests. Adsorption of short and long aliphatic chains, progressive protein (un)folding and proteinaceous cluster formation depend to a distinguishable extent on the fretting duration and type of alloy. Chromates and iron oxides are mixed with tryptophan and tyrosine, and amorphous carbon is formed resulting from a fretting-induced cleavage of serum proteins. Such information spectroscopically gleaned from biotribological material are vital to improve the design and performance of taper junctions.
Collapse
Affiliation(s)
- Adrian Wittrock
- Department of Physics, TU Dortmund University, Otto-Hahn-Str. 4a, Dortmund, 44227, Germany
| | - Saskia Heermant
- Department of Physics, TU Dortmund University, Otto-Hahn-Str. 4a, Dortmund, 44227, Germany
| | - Christian Beckmann
- Department of Physics, TU Dortmund University, Otto-Hahn-Str. 4a, Dortmund, 44227, Germany
| | - Markus A Wimmer
- Department of Orthopedic Surgery, Rush University Medical Center, 1611 W. Harrison St., Chicago, 60612, IL, USA
| | - Alfons Fischer
- Department of Orthopedic Surgery, Rush University Medical Center, 1611 W. Harrison St., Chicago, 60612, IL, USA; Department Microstructure Physics and Alloy Design, Max Planck Institute for Sustainable Materials, Max-Planck-Str. 1, Düsseldorf, 40237, Germany
| | - Marc Aßmann
- Department of Physics, TU Dortmund University, Otto-Hahn-Str. 4a, Dortmund, 44227, Germany
| | - Jörg Debus
- Department of Physics, TU Dortmund University, Otto-Hahn-Str. 4a, Dortmund, 44227, Germany.
| |
Collapse
|
2
|
Fischer A, Telouk P, Beckmann C, Heermant S, Wittrock A, Debus J, Wimmer MA. Performance of Austenitic High-Nitrogen Steels under Gross Slip Fretting Corrosion in Bovine Serum. J Funct Biomater 2024; 15:110. [PMID: 38667567 PMCID: PMC11051106 DOI: 10.3390/jfb15040110] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2024] [Revised: 04/08/2024] [Accepted: 04/09/2024] [Indexed: 04/28/2024] Open
Abstract
Modular artificial hip joints are a clinical standard today. However, the release of wear products from the head-taper interface, which includes wear particles in the nm size range, as well as metal ions, have raised concerns. Depending on the loading of such taper joints, a wide variety of different mechanisms have been found by retrieval analyses. From these, this paper concentrates on analyzing the contribution of gross slip fretting corrosion at ultra-mild wear rates using a bovine calf serum solution (BCS) as the lubricant. The parameters were chosen based on biomechanical considerations, producing wear rates of some ng/m wear path. In parallel, the evolution of tribomaterial (third bodies) was analyzed as to its constituents and generation rates. It has already been shown earlier that, by an advantageous combination of wear mechanisms and submechanisms, certain constituents of the tribomaterial remain inside the contact area and act like extreme-pressure lubricant additives. For the known wear and corrosion resistance of austenitic high-nitrogen steels (AHNSs), which outperform CoCrMo alloys even under inflammatory conditions, we hypothesized that such steels will generate ultra-mild wear rates under gross slip fretting. While testing AHNSs against commercially available biomedical-grade materials of CoCrMo and TiAlV alloys, as well as zirconia-toughened alumina (ZTA) and against itself, it was found that AHNSs in combination with a Ti6Al4V alloy generated the smallest wear rate under gross slip fretting corrosion. This paper then discusses the wear behavior on the basis of ex situ analyses of the worn surfaces as to the acting wear mechanisms and submechanisms, as well as to the tribological reaction products.
Collapse
Affiliation(s)
- Alfons Fischer
- Max Planck Institute for Sustainable Materials, Microstructure Physics and Alloy Design, 40237 Duesseldorf, Germany
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL 60612, USA;
| | - Philipe Telouk
- Laboratoire de Géologie, Université de Lyon, 69342 Lyon, France;
| | - Christian Beckmann
- Department of Physics, TU Dortmund University, 44227 Dortmund, Germany; (C.B.); (S.H.); (A.W.); (J.D.)
| | - Saskia Heermant
- Department of Physics, TU Dortmund University, 44227 Dortmund, Germany; (C.B.); (S.H.); (A.W.); (J.D.)
| | - Adrian Wittrock
- Department of Physics, TU Dortmund University, 44227 Dortmund, Germany; (C.B.); (S.H.); (A.W.); (J.D.)
| | - Jörg Debus
- Department of Physics, TU Dortmund University, 44227 Dortmund, Germany; (C.B.); (S.H.); (A.W.); (J.D.)
| | - Markus A. Wimmer
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL 60612, USA;
| |
Collapse
|