1
|
Lenzi A, De Cristofaro M, Biagini D, Ghimenti S, Armenia S, Pugliese NR, Masi S, Di Francesco F, Lomonaco T. Development of a high-throughput liquid chromatography-tandem mass spectrometry platform for the determination of intact natriuretic peptides in human plasma. Talanta 2024; 275:126077. [PMID: 38636440 DOI: 10.1016/j.talanta.2024.126077] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2023] [Revised: 04/03/2024] [Accepted: 04/06/2024] [Indexed: 04/20/2024]
Abstract
We present an innovative, reliable, and antibody-free analytical method to determine multiple intact natriuretic peptides in human plasma. These biomolecules are routinely used to confirm the diagnosis and monitor the evolution of heart failure, so that their determination is essential to improve diagnosis and monitor the efficacy of treatment. However, common immunoassay kits suffer from main limitations due to high cross-reactivity with structurally similar species. In our method, we pre-treated the sample by combining salting-out with ammonium sulfate with microextraction by packed sorbent technique. Analyses were then carried out by ultra-high performance liquid chromatography-electrospray ionization-tandem mass spectrometry. The use of 3-nitrobenzyl alcohol as a supercharger reagent enhanced the ESI ionization and improved the signal-to-noise ratio. The analytical protocol showed good linearity over one order of magnitude, recovery in the range of 94-105 %, and good intra- and inter-day reproducibility (RSD<20 %), and the presence of a matrix effect. Limits of detection were in the range of pg/mL for all peptides (0.2-20 pg/mL). Stability study in plasma samples demonstrated that proper protease inhibitors need to be included in blood collection tubes to avoid peptide degradation. Preliminary analyses on plasma samples from heart failure patients allow the quantification of ANP 1-28 as the most abundant species and the detection of ANP 5-28, BNP 1-32, and BNP 5-32. The method could be used to investigate how cross-reactivity issues among structurally similar species impact determinations by ELISA kits.
Collapse
Affiliation(s)
- Alessio Lenzi
- Department of Chemistry and Industrial Chemistry, University of Pisa, Via Giuseppe Moruzzi 13, Pisa, Italy.
| | - Mariano De Cristofaro
- Department of Chemistry and Industrial Chemistry, University of Pisa, Via Giuseppe Moruzzi 13, Pisa, Italy.
| | - Denise Biagini
- Department of Chemistry and Industrial Chemistry, University of Pisa, Via Giuseppe Moruzzi 13, Pisa, Italy.
| | - Silvia Ghimenti
- Department of Chemistry and Industrial Chemistry, University of Pisa, Via Giuseppe Moruzzi 13, Pisa, Italy.
| | - Silvia Armenia
- Department of Clinical and Experimental Medicine, University of Pisa, Via Roma 67, Pisa, Italy.
| | - Nicola R Pugliese
- Department of Clinical and Experimental Medicine, University of Pisa, Via Roma 67, Pisa, Italy.
| | - Stefano Masi
- Department of Clinical and Experimental Medicine, University of Pisa, Via Roma 67, Pisa, Italy.
| | - Fabio Di Francesco
- Department of Chemistry and Industrial Chemistry, University of Pisa, Via Giuseppe Moruzzi 13, Pisa, Italy.
| | - Tommaso Lomonaco
- Department of Chemistry and Industrial Chemistry, University of Pisa, Via Giuseppe Moruzzi 13, Pisa, Italy.
| |
Collapse
|
2
|
Nie S, O'Brien Johnson R, Livson Y, Greer T, Zheng X, Li N. Maximizing hydrophobic peptide recovery in proteomics and antibody development using a mass spectrometry compatible surfactant. Anal Biochem 2022; 658:114924. [PMID: 36162445 DOI: 10.1016/j.ab.2022.114924] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2022] [Accepted: 09/18/2022] [Indexed: 11/01/2022]
Abstract
Peptide loss due to surface absorption can happen at any step in a protein analysis workflow and is sometimes especially deleterious for hydrophobic peptides. In this study, we found the LC-MS compatible surfactant, n-Dodecyl-β-D-maltoside (DDM), can maximize hydrophobic peptide recovery in various samples including single cell digests, mAb clinical PK samples, and mAb peptide mapping samples. In HeLa single cell proteomics analysis, more than half of all unique peptides identified were found only in DDM prepared samples, most of which had significantly higher hydrophobicities compared to peptides in control samples. In clinical PK studies, DDM enhanced hydrophobic complementarity-determining region (CDR) peptide signals significantly. The fold change of CDR peptides' intensity enhancement in DDM added samples compared to controls correlate with peptide retention time and hydrophobicity, providing guidance for surrogate peptide selection and peptide standard handling in PK studies. For peptide mapping analysis of mAbs, DDM can improve hydrophobic peptide signal and solution stability over 48 h in an autosampler at 4 °C, which can aid method qualification and transfer during drug development. Lastly, maximizing hydrophobic peptide recovery from samples dried in vacuo was achieved by DDM reconstitution, which provided higher signal for later eluting peaks and higher proteome coverage overall.
Collapse
Affiliation(s)
- Song Nie
- Analytical Chemistry, Regeneron Pharmaceuticals Inc., 777 Old Saw Mill River Road, Tarrytown, NY, 10591-6707, United States.
| | - Reid O'Brien Johnson
- Analytical Chemistry, Regeneron Pharmaceuticals Inc., 777 Old Saw Mill River Road, Tarrytown, NY, 10591-6707, United States
| | - Yuliya Livson
- Analytical Chemistry, Regeneron Pharmaceuticals Inc., 777 Old Saw Mill River Road, Tarrytown, NY, 10591-6707, United States
| | - Tyler Greer
- Analytical Chemistry, Regeneron Pharmaceuticals Inc., 777 Old Saw Mill River Road, Tarrytown, NY, 10591-6707, United States
| | - Xiaojing Zheng
- Analytical Chemistry, Regeneron Pharmaceuticals Inc., 777 Old Saw Mill River Road, Tarrytown, NY, 10591-6707, United States.
| | - Ning Li
- Analytical Chemistry, Regeneron Pharmaceuticals Inc., 777 Old Saw Mill River Road, Tarrytown, NY, 10591-6707, United States
| |
Collapse
|
3
|
Feickert M, Burckhardt BB. A design of experiments concept for the minimization of nonspecific peptide adsorption in the mass spectrometric determination of substance P and related hemokinin‐1. J Sep Sci 2020; 43:818-828. [DOI: 10.1002/jssc.201901038] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2019] [Revised: 11/14/2019] [Accepted: 11/17/2019] [Indexed: 12/18/2022]
Affiliation(s)
- Martin Feickert
- Institute of Clinical Pharmacy and PharmacotherapyHeinrich Heine University Dusseldorf Germany
| | - Bjoern B Burckhardt
- Institute of Clinical Pharmacy and PharmacotherapyHeinrich Heine University Dusseldorf Germany
| |
Collapse
|
4
|
Xiao P, Li H, Li X, Song D. Analytical barriers in clinical B-type natriuretic peptide measurement and the promising analytical methods based on mass spectrometry technology. ACTA ACUST UNITED AC 2018; 57:954-966. [DOI: 10.1515/cclm-2018-0956] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2018] [Accepted: 10/22/2018] [Indexed: 12/28/2022]
Abstract
Abstract
B-type natriuretic peptide (BNP) is a circulating biomarker that is mainly applied in heart failure (HF) diagnosis and to monitor disease progression. Because some identical amino acid sequences occur in the precursor and metabolites of BNP, undesirable cross-reactions are common in immunoassays. This review first summarizes current analytical methods, such as immunoassay- and mass spectrometry (MS)-based approaches, including the accuracy of measurement and the inconsistency of the results. Second, the review presents some promising approaches to resolve the current barriers in clinical BNP measurement, such as how to decrease cross-reactions and increase the measurement consistency. Specific approaches include research on novel BNP assays with higher-specificity chemical antibodies, the development of International System of Units (SI)-traceable reference materials, and the development of structure characterization methods based on state-of-the-art ambient and ion mobility MS technologies. The factors that could affect MS analysis are also discussed, such as biological sample cleanup and peptide ionization efficiency. The purpose of this review is to explore and identify the main problems in BNP clinical measurement and to present three types of approaches to resolve these problems, namely, materials, methods and instruments. Although novel approaches are proposed here, in practice, it is worth noting that the BNP-related peptides including unprocessed proBNP were all measured in clinical BNP assays. Therefore, approaches that aimed to measure a specific BNP or proBNP might be an effective way for the standardization of a particular BNP form measurement, instead of the standardization of “total” immunoreactive BNP assays in clinical at present.
Collapse
Affiliation(s)
- Peng Xiao
- Division of Chemical Metrology and Analytical Science , National Institute of Metrology , Beijing 100029 , P.R. China , Phone: +86-10-64228896, Fax: +86-10-64271639
| | - Hongmei Li
- Division of Chemical Metrology and Analytical Science , National Institute of Metrology , Beijing 100029 , P.R. China , Phone: +86-10-64228896, Fax: +86-10-64271639
| | - Xianjiang Li
- Division of Chemical Metrology and Analytical Science , National Institute of Metrology , Beijing , P.R. China
| | - Dewei Song
- Division of Chemical Metrology and Analytical Science , National Institute of Metrology , Beijing , P.R. China
| |
Collapse
|
5
|
Fully-automated systems and the need for global approaches should exhort clinical labs to reinvent routine MS analysis? Bioanalysis 2018; 10:1129-1141. [DOI: 10.4155/bio-2018-0074] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022] Open
Abstract
Today, many LC–high-resolution MS instruments have become affordable, easy-to-use, sensitive and quantitative. Meanwhile, there is an increased need for more comprehensive approaches. However, omics analyses are still restricted to specialists whereas, in hospitals, routine analyses are targeted and quantitative and represent the main and heavy tasks. But the availability of fully automated LC–MS instruments that can handle independently from sample extraction to result reporting, as well as the increasing biomedical interest for global approaches, clinical analytical workflow should be reorganized. Bioanalysts are now in the position to develop/implement clinical metabolomics or proteomics as routine analyses. In this article, this coming evolution and the reasons to implement global/omics determinations as routine analysis, is described.
Collapse
|
6
|
Yan Z, Yan R. Exploring the Potential of Data-Independent Acquisition Proteomics Using Untargeted All-Ion Quantitation: Application to Tumor Subtype Diagnosis. Anal Chem 2018. [PMID: 29522333 DOI: 10.1021/acs.analchem.7b03920] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
Abstract
Maximizing the recovery of meaningful biological information can facilitate proteomics-guided early detection and precise treatment of diseases. However, the conventional protein and peptide level targeted quantification of untargeted data independent acquisition (DIA) such as sequential window acquisition of all theoretical spectra (SWATH) is not necessarily descriptive of all information. Untargeted all-ion quantification theoretically could retrieve more features in SWATH digital maps by circumventing the initial identification process but is intrinsically susceptible to errors because of the extreme complexity of proteome samples and the poor selectivity of a single ion. In this study, we optimized and applied the untargeted all-ion quantification of SWATH data to differentiate tumor subtypes. Large peptides and low abundant peptides benefited more from untargeted all-ion quantification. Top-ranked significant ions were linked to their corresponding ion envelops, where multiple correlated ions were used for measurement and only ion envelopes containing at least three ions with consistent intensity ratio were kept as refined differentiating features. Multivariate statistical analysis revealed that for the tested data set, the refined markers discovered by untargeted SWATH analysis showed comparable diagnostic power to protein and peptide markers. Limitations and benefits of the approach are further discussed.
Collapse
Affiliation(s)
- Zhixiang Yan
- State Key Laboratory of Quality Research in Chinese Medicine, Institute of Chinese Medical Sciences , University of Macau , Taipa, Macao , China.,Zhuhai UM Science & Technology Research Institute , Zhuhai 519080 , China
| | - Ru Yan
- State Key Laboratory of Quality Research in Chinese Medicine, Institute of Chinese Medical Sciences , University of Macau , Taipa, Macao , China.,Zhuhai UM Science & Technology Research Institute , Zhuhai 519080 , China
| |
Collapse
|
7
|
Sensitive analysis of N-blocked amino acids using high-performance liquid chromatography with paired ion electrospray ionization mass spectrometry. Anal Bioanal Chem 2018; 410:4725-4735. [DOI: 10.1007/s00216-018-0901-5] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2017] [Revised: 12/19/2017] [Accepted: 01/18/2018] [Indexed: 01/03/2023]
|
8
|
Torma AF, Groves K, Biesenbruch S, Mussell C, Reid A, Ellison S, Cramer R, Quaglia M. A candidate liquid chromatography mass spectrometry reference method for the quantification of the cardiac marker 1-32 B-type natriuretic peptide. Clin Chem Lab Med 2017; 55:1397-1406. [PMID: 28426429 DOI: 10.1515/cclm-2016-1054] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2016] [Accepted: 03/09/2017] [Indexed: 12/16/2022]
Abstract
BACKGROUND B-type natriuretic peptide (BNP) is a 32 amino acid cardiac hormone routinely measured by immunoassays to diagnose heart failure. While it is reported that immunoassay results can vary up to 45%, no attempt of standardization and/or harmonization through the development of certified reference materials (CRMs) or reference measurement procedures (RMPs) has yet been carried out. METHODS B-type natriuretic peptide primary calibrator was quantified traceably to the International System of Units (SI) by both amino acid analysis and tryptic digestion. A method for the stabilization of BNP in plasma followed by protein precipitation, solid phase extraction (SPE) and liquid chromatography (LC) mass spectrometry (MS) was then developed and validated for the quantification of BNP at clinically relevant concentrations (15-150 fmol/g). RESULTS The candidate reference method was applied to the quantification of BNP in a number of samples from the UK NEQAS Cardiac Markers Scheme to demonstrate its applicability to generate reference values and to preliminary evaluate the commutability of a potential CRM. The results from the reference method were consistently lower than the immunoassay results and discrepancy between the immunoassays was observed confirming previous data. CONCLUSIONS The application of the liquid chromatography-mass spectrometry (LC-MS) method to the UK NEQAS samples and the correlation of the results with the immunoassay results shows the potential of the method to support external quality assessment schemes, to improve understanding of the bias of the assays and to establish RMPs for BNP measurements. Furthermore, the method has the potential to be multiplexed for monitoring circulating truncated forms of BNP.
Collapse
|
9
|
Rochat B. From targeted quantification to untargeted metabolomics: Why LC-high-resolution-MS will become a key instrument in clinical labs. Trends Analyt Chem 2016. [DOI: 10.1016/j.trac.2016.02.009] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
|
10
|
Quantitative performance of a quadrupole-orbitrap-MS in targeted LC–MS determinations of small molecules. J Pharm Biomed Anal 2016; 124:48-56. [DOI: 10.1016/j.jpba.2016.02.025] [Citation(s) in RCA: 51] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2016] [Revised: 02/15/2016] [Accepted: 02/17/2016] [Indexed: 11/23/2022]
|
11
|
Multiple stage MS in analysis of plasma, serum, urine and in vitro samples relevant to clinical and forensic toxicology. Bioanalysis 2016; 8:457-81. [DOI: 10.4155/bio.16.15] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022] Open
Abstract
This paper reviews MS approaches applied to metabolism studies, structure elucidation and qualitative or quantitative screening of drugs (of abuse) and/or their metabolites. Applications in clinical and forensic toxicology were included using blood plasma or serum, urine, in vitro samples, liquids, solids or plant material. Techniques covered are liquid chromatography coupled to low-resolution and high-resolution multiple stage mass analyzers. Only PubMed listed studies published in English between January 2008 and January 2015 were considered. Approaches are discussed focusing on sample preparation and mass spectral settings. Comments on advantages and limitations of these techniques complete the review.
Collapse
|
12
|
Temperature-based on-column solute focusing in capillary liquid chromatography reduces peak broadening from pre-column dispersion and volume overload when used alone or with solvent-based focusing. J Chromatogr A 2015; 1405:133-9. [PMID: 26091787 DOI: 10.1016/j.chroma.2015.05.071] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2015] [Revised: 05/21/2015] [Accepted: 05/30/2015] [Indexed: 01/25/2023]
Abstract
On-column focusing is essential for satisfactory performance using capillary scale columns. On-column focusing results from generating transient conditions at the head of the column that lead to high solute retention. Solvent-based on-column focusing is a well-known approach to achieve this. Temperature-assisted on-column focusing (TASF) can also be effective. TASF improves focusing by cooling a short segment of the column inlet to a temperature that is lower than the column temperature during the injection and then rapidly heating the focusing segment to the match the column temperature. A troublesome feature of an earlier implementation of TASF was the need to leave the capillary column unpacked in that portion of the column inside the fitting connecting it to the injection valve. We have overcome that problem in this work by packing the head of the column with solid silica spheres. In addition, technical improvements to the TASF instrumentation include: selection of a more powerful thermo-electric cooler to create faster temperature changes and electronic control for easy incorporation into conventional capillary instruments. Used in conjunction with solvent-based focusing and with isocratic elution, volumes of paraben samples (esters of p-hydroxybenzoic acid) up to 4.5-times the column liquid volume can be injected without significant bandspreading due to volume overload. Interestingly, the shapes of the peaks from the lowest volume injections that we can make, 30nL, are improved when using TASF. TASF is very effective at reducing the detrimental effects of pre-column dispersion using isocratic elution. Finally, we show that TASF can be used to focus the neuropeptide galanin in a sample solvent with elution strength stronger than the mobile phase. Here, the stronger solvent is necessitated by the need to prevent peptide adsorption prior to and during analysis.
Collapse
|
13
|
Improved sensitivity of the nano ultra-high performance liquid chromatography-tandem mass spectrometric analysis of low-concentrated neuropeptides by reducing aspecific adsorption and optimizing the injection solvent. J Chromatogr A 2014; 1360:217-28. [DOI: 10.1016/j.chroma.2014.07.086] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2014] [Revised: 07/15/2014] [Accepted: 07/27/2014] [Indexed: 11/18/2022]
|
14
|
Maes K, Smolders I, Michotte Y, Van Eeckhaut A. Strategies to reduce aspecific adsorption of peptides and proteins in liquid chromatography-mass spectrometry based bioanalyses: an overview. J Chromatogr A 2014; 1358:1-13. [PMID: 25022477 DOI: 10.1016/j.chroma.2014.06.072] [Citation(s) in RCA: 64] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2014] [Revised: 06/11/2014] [Accepted: 06/22/2014] [Indexed: 12/20/2022]
Abstract
In the drug-discovery setting, the development of new peptide and protein-based biopharmaceuticals attracts increased attention from the pharmaceutical industry and consequently demands the development of high-throughput LC-MS methods. Regulatory guidelines require bioanalytical methods to be validated not only in terms of linearity, sensitivity, accuracy, precision, selectivity and stability, but also in terms of carryover. Carryover results from the aspecific adsorption of analyte(s) to parts of the analytical system and thus introduces bias in both identification and quantification assays. Moreover, nonspecific binding occurs at the surface of materials used during sample preparation, such as pipette tips, sample tubes and LC-vials. Hence, linearity, sensitivity and repeatability of the analyses are negatively affected. Due to the great diversity in physicochemical properties of biomolecules, there is no general approach available to minimize adsorption phenomena. Therefore, we aim to present different strategies which can be generically applied to reduce nonspecific binding of peptides and proteins. In the first part of this review, a systematic approach is proposed to guide the reader through the different solvents which can be used to dissolve the analyte of interest. Indeed, proper solubilization is one of the most important factors for a successful analysis. In addition, alternative approaches are described to improve analyte recovery from the sample vial. The second part focuses on strategies to efficiently reduce adsorption at components of the autosampler, column and mass spectrometer. Thereby carryover is reduced while maintaining a sufficiently wide dynamic range of the assay.
Collapse
Affiliation(s)
- Katrien Maes
- Department of Pharmaceutical Chemistry and Drug Analysis, Center for Neurosciences (C4N), Vrije Universiteit Brussel, Laarbeeklaan 103, 1090 Brussels, Belgium
| | - Ilse Smolders
- Department of Pharmaceutical Chemistry and Drug Analysis, Center for Neurosciences (C4N), Vrije Universiteit Brussel, Laarbeeklaan 103, 1090 Brussels, Belgium
| | - Yvette Michotte
- Department of Pharmaceutical Chemistry and Drug Analysis, Center for Neurosciences (C4N), Vrije Universiteit Brussel, Laarbeeklaan 103, 1090 Brussels, Belgium
| | - Ann Van Eeckhaut
- Department of Pharmaceutical Chemistry and Drug Analysis, Center for Neurosciences (C4N), Vrije Universiteit Brussel, Laarbeeklaan 103, 1090 Brussels, Belgium.
| |
Collapse
|
15
|
Wang H, Duan JA, Guo S, Qian D, Shang E. Development and validation of a hydrophilic interaction ultra-high-performance liquid chromatography with triple quadrupole MS/MS for the absolute and relative quantification of amino acids in Sophora alopecuroides
L.†. J Sep Sci 2013; 36:2244-52. [DOI: 10.1002/jssc.201300266] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2013] [Revised: 04/22/2013] [Accepted: 04/23/2013] [Indexed: 12/23/2022]
Affiliation(s)
- Hanqing Wang
- Jiangsu Key Laboratory for High Technology Research of TCM Formulae; Nanjing University of Chinese Medicine; Nanjing P. R. China
- College of Pharmacy; Ningxia Medical University; Yinchuan Ningxia P. R China
| | - Jin-ao Duan
- Jiangsu Key Laboratory for High Technology Research of TCM Formulae; Nanjing University of Chinese Medicine; Nanjing P. R. China
| | - Sheng Guo
- Jiangsu Key Laboratory for High Technology Research of TCM Formulae; Nanjing University of Chinese Medicine; Nanjing P. R. China
| | - Dawei Qian
- Jiangsu Key Laboratory for High Technology Research of TCM Formulae; Nanjing University of Chinese Medicine; Nanjing P. R. China
| | - Erxin Shang
- Jiangsu Key Laboratory for High Technology Research of TCM Formulae; Nanjing University of Chinese Medicine; Nanjing P. R. China
| |
Collapse
|
16
|
Stejskal K, Potěšil D, Zdráhal Z. Suppression of Peptide Sample Losses in Autosampler Vials. J Proteome Res 2013; 12:3057-62. [DOI: 10.1021/pr400183v] [Citation(s) in RCA: 56] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Affiliation(s)
- Karel Stejskal
- Research
Group Proteomics, Central European Institute of Technology and ‡National Centre
for Biomolecular Research, Faculty of Science, Masaryk University, Kamenice 5, 625 00 Brno, Czech
Republic
| | - David Potěšil
- Research
Group Proteomics, Central European Institute of Technology and ‡National Centre
for Biomolecular Research, Faculty of Science, Masaryk University, Kamenice 5, 625 00 Brno, Czech
Republic
| | - Zbyněk Zdráhal
- Research
Group Proteomics, Central European Institute of Technology and ‡National Centre
for Biomolecular Research, Faculty of Science, Masaryk University, Kamenice 5, 625 00 Brno, Czech
Republic
| |
Collapse
|
17
|
Comparison of triple quadrupole and high-resolution TOF-MS for quantification of peptides. Bioanalysis 2012; 4:565-79. [DOI: 10.4155/bio.12.3] [Citation(s) in RCA: 74] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Background: With an increased interest in peptides and proteins as potential new drug candidates, new approaches for sensitive and selective quantitative analysis are required. LC–MS/MS analysis provides a good alternative to immunoassays with reduced method development times and increased specificity. Results: We have evaluated two state-of-the-art triple quadrupole and high-resolution TOF mass spectrometers with respect to their performance for quantification of six peptides (glufibrinopeptide B, somatostatin, enfuvirtide, TRI1144, C34 and exenatide). The peptides were spiked into protein-precipitated plasma supernatant. Triple quadrupole quantification was performed in SRM mode, and in high-resolution, MS narrow-width extracted chromatograms were generated for quantification. Specificity, accuracy, reproducibility and robustness were found to be comparable between the two instruments. The triple quadrupole instrument is still the most sensitive instrument for quantification of peptides with a median factor of about four-times higher sensitivity (based on LLOQ evaluation). Conclusion: Based on sensitivity, the newest generation triple quadrupole MS systems are still the preferred technology for quantification of peptides. Since the sensitivity difference between triple quadrupole instruments and the new-generation high-resolution TOF-MS instruments is minor, the latter offer a useful alternative whenever additional selectivity is preferred or the use of a generic approach not requiring method optimization is advantageous.
Collapse
|
18
|
The absolute quantification of endogenous levels of brain neuropeptides in vivo using LC-MS/MS. Bioanalysis 2011; 3:1271-85. [PMID: 21649502 DOI: 10.4155/bio.11.91] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Neuropeptides seem to play an important role when the CNS is challenged. In order to obtain better insights into the central peptidergic effects, it is essential to monitor their concentration in the brain. Quantification of neuropeptides in dialysates is challenging due to their low extracellular concentrations (low pM range), their low microdialysis efficiencies, the need for acceptable temporal resolution, the small sample volumes, the complexity of the matrix and the tendency of peptides to stick to glass and polymeric materials. The quantification of neuropeptides in dialysates therefore necessitates the use of very sensitive nano-LC-MS/MS methods. A number of LC-MS/MS and microdialysis parameters need to be optimized to achieve maximal sensitivity. The optimized and validated methods can be used to investigate the in vivo neuropeptide release during pathological conditions, in this way initiating new and immense challenges for the development of new drugs.
Collapse
|